Loading...
20180327 Engineering CalcsCopyright 2018, SEGA Engineers STRUCTURAL CALCULATIONS FOR THE SOUNDBUILT HOMES RESIDENTIAL PROJECT Plan L2-2048-2 May 10, 2018 Job No. : 13-044 Location: Lots 245 - 251, Tahoma Terra Yelm, Washington SEGA Engineers Structural & Civil Consulting Engineers 22939 SE 292nd PL (360) 886-1017 Black Diamond, WA 98010 0 0 0 05555////10101010/1/1/1/18888 STATEMENT OF WORK SEGA Engineers was asked to provide a lateral loads analysis, shear wall design, review of major framing members and foundation, and drawing red-lines for a two-story wood framed single family residence. The roof framing is manufactured trusses, the floor framing is 2x dimensional or wood I-joists, and the foundation is typical concrete strip footings with a crawl space. The application and use of these calculations is limited to a single site referenced on the cover sheet. The cover sheet should have an original signature in blue ink over the seal. The attached calculations may or may not apply to other sites and the contractor assumes all responsibility and liability for sites not expressly reviewed and approved. Please contact SEGA Engineers for use at other sites. SEGA Engineers will use that degree of care and skill ordinarily exercised under similar circumstances by members of the engineering profession in this local. No other warranty, either expressed or implied is made in connection with our rending of professional services. For any dispute, claim, or action arising out of this design, SEGA Engineers shall have liability limited to the amount of the total fee received by SEGA Engineers. Questions regarding the attached should be addressed to SEGA Engineers. Greg Thesenvitz, PE/SE SEGA Engineers SEGA Engineers Project L2-2048 Copyright 2017, SEGA Engineers SEGA Engineers Project L2-2048SEGA Engineers Project L2-2048 Structural & Civil Consulting Engineers Structural & Civil Consulting Engineers Structural & Civil Consulting Engineers Job No.13-044 By:GATJob No.13-044 By:GATJob No.13-044 By:GAT 22939 SE 292nd PL (360) 886-101722939 SE 292nd PL (360) 886-1017 Black Diamond, WA 98010 Checked Date:04/11/17 Sht 1 Black Diamond, WA 98010 Checked Date:04/11/17 Sht 1 Design CriteriaDesign CriteriaDesign Criteria International Building Code (IBC), 2015International Building Code (IBC), 2015International Building Code (IBC), 2015 LOADSLOADSLOADS RoofRoofRoof DL 15 psfDL15psf LL 25 psfLL25psfLL25psf FloorFloorFloor DL 12 psfDL12psf LL 40 psfLL40psfLL40psf WindWindWind Risk Category IIRisk Category IIRisk Category II Design Wind Speed 110 mph (Vult)Design Wind Speed 110 mph (Vult)Design Wind Speed 110 mph ult Kzt 1.00Kzt1.00zt Exposure BExposureB SeismicSeismicSeismic Design Category DDesign Category DDesign Category D SDS 1.00SDS1.00DS Response Factor 6.5Response Factor 6.5 C =0.154CS =0.154CS =0.154 Importance Factor 1.00Importance Factor 1.00Importance Factor 1.00 SoilSoilSoil Allowable Bearing 1,500 psfAllowable Bearing 1,500 psfAllowable Bearing 1,500 psf Copyright 2017, SEGA EngineersCopyright 2017, SEGA Engineers SEGA Engineers, Structural & Civil Consulting Engineers 22939 SE 292nd PL (360) 886-1017 Black Diamond, WA 98010 LOADS ROOF DL Roofing (Comp) '/z" OSB 2 x @ 24" Insulation 518" GWB Misc. LL Snow, Pf Reduction, Cs 5112 pitch = 23 deg Total Roof Load FLOOR DL LL DECKS DL LL WALLS DL Copyright 2013, SEGA Engineers Flooring 314" Plywood 2x12@12"oc 518" GWB Misc. Residential Total Floor Load 2 x Decking 2x10@16"oc Misc Residential Total Deck Load Siding '/z" Plywood 2x6@16"oc Insul 1/2" GWB Project 1-2-2048 Job No. 13-044 By: GAT Checked Date: 07/05/13 Sht -I- 3.5 L 3.5 psf 1.8 3.5 1.1 2.8 1.5 14.2 psf 25 psf (115% Load Duration) 0.00 (Ct = 1.1, other surfaces) 39.2 psf 0.5 psf 2.3 4.4 2.8 1.5 11.5 psf 40 psf 51.5 psf 4.3 psf 2.8 1.5 8.6 40 psf 48.6 psf 3.5 1.5 psf 1.7 0.6 2.2 9.5 psf SEGA Engineers PROJECT 43 Structural & Civil Consulting Engineers L -` - JOB NO. _ O FIGURED BY C-) 4 22939 SE 292nd Place - -� Black Diamond, Washington 98010 CHECKED BY DATE9 /y3 SHEET3 OF (360) 886-1017 ► N L - 0!w lL �c�A�' Sao►Z i 5 V L 5,))L /).jr 7�' 'T Ix 4P Lr Iq 3z< �r for /-LL43ri %Z,M Al tw L-14 41L -t-- �i t 7- 4nk— Copyright 2013, SEGA Engineers SEGA Engineers PROJECT L, — zo Structural & Civil Consulting Engineers JOB NO. f 3�p „�. FIGURED BY �A'r 22939 SE 292nd Place Black Diamond, Washington 98010 CHECKED BY DATE 5IJ-., SHEE OF (360} 886-1017 __. / w� /r L., K �[ O{�T( z,UV)()z,�')x" �v3 k/a�k/,w,� i i SD sle 0r mk Copyright 2013, SEGA Engineers SEGA Engineers Project L2-2048 Structural & Civil Consulting Engineers Job No. 13-044 BY: GAT 22939 SE 292nd PL (360) 886-1017 Black Diamond, WA 98010 Checked Date: 07/05/13 Sht. LATERAL LOADS - (Alternate ASD) SEISMIC Maximum Base Shear, V = F SDS W R Eq. 12.14-11 where, F = 1.1 Two -Story Building SDs = 1.00 SS = 1.5 Fa = 1 00 (Table 11.4-1, SS > 1.25) R = 6.5 Table 12.14-1 W = Seismic Weight For W: W..f= (25ft) (52ft) (16psf)+ (2) (25ft+ 52ft) (4.Oft) (9.5psf) = 27kips Wpaor= (25ft) (52ft) (14psf)+ (2) (25ft+ 49ft) (8.5ft) (9.5psf) = 30kips W total = 5^7 kips Design Base Shear, V = ( .169) (57 kip) = 9.6 kip (17.7psf) + (25ft) E = 9.6 kip = 6.9 kip + (25ft) (1ft) (186 psf) 1.4 Vs15= 55 ft {10ft) WIND (17.7psf) _ _ + (52ft) (5ft) (17.7 psf) + (17ft) (5ft) Design Wind Pressure, p5 = X Kzt ps3o ( 6 ft) Eq. 28.6-1, Sect. 28.6.3 (18 6 psf) where, Therefore, Wind Loads Govern for Lateral Design - Front/Back Wind Loads Govern for Lateral Design - Side/Side = 1.00 0 - 15 ft Exposure B Figure 28.6-1 = 1.00 20 ft = 1.00 25 ft = 1.00 30 ft = 1.05 35 ft Kn = 1.00 Section 26.8 p3o = 17.7 psf 110 mph Figure 28.6-1 (ASD) Po -15 = ( 1.00 ) ( 1.00 ) (17 7 psf) = 17.70 psf ( x 0.6 = 10.62 psf) P20 = ( 1.00 ) ( 1.00 ) (17 7 psf) = 17.70 psf (x 0.6 = 10.62 psf) P25 = ( 1.00 ) ( 1.00 ) (17.7 psf) = 17.70 psf ( x 0.6 = 10.62 psf) P30 = ( 1.00 ) ( 1.00 ) (17 7 psf) = 17.70 psf ( x 0.6 = 10.62 psf) P35 = ( 1.05 ) ( 1.00 ) (17.7 psf) = 18.59 psf ( x 0.6 = 11.15 psf) Design Base Shear: (Wind) Vflb= (25ft) {10 ft) (17.7 psf) + (25ft) (5ft) (17.7psf) + (25ft) (5ft) (177 psf) + (25ft) (5ft) (17.7psf) + (25ft) (1ft) (186 psf) =11.5x0.6 6.9 kips Vs15= 55 ft {10ft) (177 psf) + (52ft) (5ft) (17.7psf) _ _ + (52ft) (5ft) (17.7 psf) + (17ft) (5ft) (17.7 psf) + ( 6 ft) ( 1 ft) (18 6 psf) =20.6 x 0.6 = 12.3 kips Therefore, Wind Loads Govern for Lateral Design - Front/Back Wind Loads Govern for Lateral Design - Side/Side Copyright 2013, SEGA Engineers SEGA En ineers PROJECT L Z'" Z.D Structural & Civil Consulting Engineers 22939 5E 292nd Place JOB NO. FIGURED BY CT , Black Diamond, Washington 98010 oil, (360) 886-1017 CHECKED BY DATE f J SHEET �.�P �7•ao+L. y� = 1,to = Z, Z,"111��, z 1 s t l! rel Z5 - 4 4' Ur- = z17?0 Copyright 2013, SEGA Engineers 4 SEGA En ineers 91 PROJECT Lz--1 LL s f; TT— Structural & Civil Consulting Engineers JOB NO. r3_0 -FIGURED BY 22939 SE 292nd Place - / Black Diamond, Washington 98010 CHECKED BY DATI�i/a�,y SHEET JjOF (360) 886-1017 --�fHe�r- W4u--4r4 'EDu- LL # I -P - 4,�' - 4, L4 - !,-K g If �35-r-tr I I - d ZgML �t 5 je�•. " 11 voq #4` . � �-ZPLI, D Copyright 2013, SEGA Engineers "`1` L&?-I)s W P LS'�{n (VI It' �~ Sl. — — 7 i ` q ;Pr- �SA3 6 L~Z3a ZL P LS'�{n (VI It' �~ Sl. — — 7 i ` q ;Pr- �SA3 6 SEGA En ineers PROJECT Structural & Civil Consulting Engineers LZ — �� 4S -- JOE NO. FIGURED BY 22939 SE 292nd Place Black Diamond, Washington 98010 5~ � c1�cxED BY DATE //s SHEETF (360) 886-1017 --�NELj= 44r�-- sf6t 1,0 Pr r r � 4,'L ,, 4 51 C D 7IL I � 06,00y A / 7. Copyright 2013, SEGA Engineers -z5 a'pL --" �> L to Nz-4* sr46)v r L to Nz-4* sr46)v SEGA ]Engineers Structural & Civil Consulting Engineers 22939 SE 292nd Place • Black Diamond, Washington 98010 (360) 886-1017 • FAX 886-1016 PROJECT PLAN L2 -204a JOB NO. 13-044 FIGURED BY GAT CHECKED BY DATE 05/10/1E5 SHEET 9 OF SMEAR WALL KEY PLAN 7 111 A UPPER FLOOR A = 1,223 5Q FT A 4TS20 - GIRDER A TO TOP PLATE 5 L6TA36 - HDR 4 SILL 0 ` TO 3. BL (11P.2 PLA E5) 2 3. L57A36 - HDR 4 51LL TO"BLOCKING. LSTA36-HDR ! ILL A (TYP. 2 PLACES) TO 3x BLOOKING. G'y'p C r C (ttP. 2 PLACES) - �—HT520 -BEAM TO TOP PLATE � MAIN FLOOR A = 025 50 FT s bQ ryl L5TA24-11EAM TO TOP PLATE l A = 386 5Q FT o rTrP. of v SHEAR WALL SCHEDULESHEAR WALL SCHEDULESHEAR WALL SCHEDULEMarkMinimumSheathingAnchorRemarks (4)MarkMinimumSheathing AnchorRemarks (4)Sheathing (1)Nailing (1)Bolts (3)Sheathing (1)Nailing (1)Bolts (3)15A1/2" OSB or8d@6"oc5/8"@60"ocQall = 230 plfA/2 OSB or8d @ 6 o.c./8 @ 60 o.c.Qall = 230 plfCDXCDXB1/" OSB or8d@4"oc5/"@32"ocQall = 350 plfB1/2" OSB or8d @ 4" o.c.5/8" @ 32" o.c.Qall = 350 plf2@8@QpCDXCDXCDXC1/" OSB8d@3"5/" @ 16"Q ll 450 lfC1/2" OSB or8d @ 3" o.c.5/8" @ 16" o.c.Qall = 450 plfC/2 OSB or8d @ 3 o.c./8 @ 16 o.c.Qall 450 plfCDXUii 3dCDXUse minimum 3x studsCDXUse minimum 3x studstbtti ldat abutting panel edgesat abutting panel edgesdt iland stagger nails.and stagger nails.RSee Detail 12/S2 0 for ConstructionRSee Detail 12/S2.0 for ConstructionNtNotes:Notes:1)All ll d i t d " " h ll E t i ll h ll b h th d ith t d h thi1)All walls designated " " are shear walls. Exterior walls shall be sheathed with rated sheathing1)All walls designated are shear walls. Exterior walls shall be sheathed with rated sheathing(24/0 OSB CDX) d il d t ll l d (Bl k d) h d l ( ) N ili t(24/0, OSB or CDX) and nailed at all panel edges (Blocked) per schedule (uno). Nailing at (24/0, OSB or CDX) and nailed at all panel edges (Blocked) per schedule (uno). Nailing at i t di t f i t b t 12" N ili t ll d t h ll b IBC T bl 2304 9 1intermediate framing to be at 12" oc. Nailing not called out shall be per IBC Table 2304.9.1.intermediate framing to be at 12 oc. Nailing not called out shall be per IBC Table 2304.9.1.2)Holdowns and other framing hardware by Simpson or equal to be used per plan Ends of shear2)Holdowns and other framing hardware by Simpson or equal to be used per plan. Ends of shear 2)Holdowns and other framing hardware by Simpson or equal to be used per plan. Ends of shear walls shall use double studs minimum (UNO)walls shall use double studs minimum (UNO).walls shall use double studs minimum (UNO).3)Use minimum of (2) bolts per sill piece with one bolt located not more than 12" nor less than 5"3)Use minimum of (2) bolts per sill piece with one bolt located not more than 12" nor less than 5")() p pfrom each end of the piece Embed bolts a minimum of 7" into concretefrom each end of the piece. Embed bolts a minimum of 7" into concrete.p4)Allowable loads are permitted to be increased by 40% for wind design in accordance with4)Allowable loads are permitted to be increased by 40% for wind design in accordance with)pygIBC Section 2306 3IBC Section 2306.3.