20190017 B KWN0118J-163136 Truss LayoutAlpine, an ITW Company
8801 Folsom Blvd., Suite 107
Sacramento, CA 95826
Phone: (800)877-3678 (916)387-0116
Fax: (916)387-1110
sacseals@itwbcg.com
Site Information:Page 1:
Customer: Tru-Truss, Inc.Job Number: KWN0118J
Job Description: KW NORTHWEST
Address: TUMWATER, WA
Job Engineering Criteria:
Design Code: IRC 2015 View Version: IRC 2015
JRef #: 1WHY71730001
Wind Standard: ASCE 7-10 Roof Load (pdf): 25.00- 7.00- 0.00-10.00
Wind Speed (mph): 110 Floor Load (psf): None
This package contains general notes pages, 11 truss drawing(s) and 4 detail(s).
Item Seal #Truss Item Seal #Truss
1 021.19.1612.41400 A 17' GE 2 021.19.1612.43953 A1 17' COM
3 021.19.1614.59353 B 24'6" STD COM 4 021.19.1615.00977 B1 24'6" COM
5 021.19.1615.25370 B2 24'6" GE 6 021.19.1615.29930 C 41' COM
7 021.19.1615.47407 C1 41' GE 8 021.19.1616.04210 M 9'11"8 MONO GE
9 021.19.1616.12657 M1 9'11"8 MONO 10 021.19.1616.17053 M2 3'11"8 MONO GE
11 021.19.1616.19877 M3 3'11"8 MONO
Printed 1/21/2019 4:31:36 PM
01/21/2019
WA COA #1931
General Notes
Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities:
The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1,
Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate
Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design
Specification for Wood Construction by AF&PA. The truss component designs are based on the specified loading and
dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to
independently verify the accuracy or completeness of the information provided by others and may rely on that information
without liability. The responsibility for verification of that information remains with others neither employed nor controlled
by the Truss Design Engineer. The Truss Design Engineer’s seal and signature on the attached drawings, or cover page
listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component
designs and not for the technical information furnished by others which technical information and consequences thereof
remain their sole responsibility.
The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in
accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and
loads for each truss component match those required by the plans and by the actual use of the individual component, and
for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any
additional factors required in the particular application. Truss components using metal connector plates with integral teeth
shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to
exceed 19% and/or cause corrosion of connector plates and other metal fasteners.
The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set
forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss
component design loads, inspection of the truss components before or after installation, the design of temporary or
permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear
walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the
foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports,
installation of the truss components, observation of the truss component installation process, review of truss assembly
procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in
the installation of the truss components and/or its connections.
This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic
file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request.
Temporary Lateral Restraint and Bracing:
Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2,
B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or
other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these
drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to
and may not be relied upon for the temporary stability of the truss components during their installation.
Permanent Lateral Restraint and Bracing:
The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of
the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of
BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional.
These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building
stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building
Designer.
Connector Plate Information:
Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations,
gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60.
Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at
www.icc-es.org.
Page 1 of 2
General Notes (continued)
Key to Terms:
Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed
information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be
found in calculation sheets available upon written request.
BCDL = Bottom Chord standard design Dead Load in pounds per square foot.
BCLL = Bottom Chord standard design Live Load in pounds per square foot.
Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot.
HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches.
HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep
adjustment.
HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds.
L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value.
L/defl = ratio of Length between bearings, in inches, divided by the immediate vertical Deflection, in inches, at the
referenced panel point. Reported as 999 if greater than or equal to 999.
Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection.
Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases.
Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases.
Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases.
NCBCLL = Non-Concurrent Bottom Chord design Live Load in pounds per square foot.
PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds.
PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds
PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds.
PP = Panel Point.
R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc).
-R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc).
Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the
indicated location (Loc).
RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non-gravity (wind or seismic)
load cases, at the indicated location (Loc).
Rw = maximum downward design Reaction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the
identified location (Loc).
TCDL = Top Chord standard design Dead Load in pounds per square foot.
TCLL = Top Chord standard design Live Load in pounds per square foot.
U = maximum Upward design reaction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the
indicated location (Loc).
VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in
inches.
VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load.
VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment.
W = Width of non-hanger bearing, in inches.
Refer to ASCE-7 for Wind and Seismic abbreviations.
Uppercase Acronyms not explained above are as defined in TPI 1.
References:
1. AF&PA: American Forest & Paper Association, 1111 19th Street, NW, Suite 800, Washington, DC 20036;
www.afandpa.org.
2. ICC: International Code Council; www.iccsafe.org.
3. Alpine, a division of ITW Building Components Group Inc.: 13723 Riverport Drive, Suite 200, Maryland Heights, MO
63043; www.alpineitw.com.
4. TPI: Truss Plate Institute, 218 North Lee Street, Suite 312, Alexandria, VA 22314; www.tpinst.org.
5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindustry.co
Page 2 of 2
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 1-6-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS A11530ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Top chord may be notched 1.5" deep X 3.5"
at 48" o/c along top edge. DO NOT OVERCUT.
No knots or other lumber defects allowed within
12" of notches. Do not notch in overhang, (NNL),
or heel (first) panels.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*134 /-/-/45 /26 /7
Wind reactions based on MWFRS
B Brg Width = 204 Min Req =-
Bearing B is a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.03 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.002 H 999 360
VERT(CL):0.002 Y 999 240
HORZ(LL):-0.001 D - -
HORZ(TL):0.002 D - -
Creep Factor: 2.0
Max TC CSI:0.326
Max BC CSI:0.055
Max W eb CSI:0.043
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:A 17' GE
Ply: 1
Qty:2
SEQN:762689 T2 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1612.41400
CY /GWH 01/21/2019
A
B
H
N
O
5
12
2X4(A1T)
3X5
2X4(A1T)
17'
2'8"1'4"
(TYP)
8'6"
8'6"
17'
8'6"
17'
17'1'6"1'6"
4"13'10"94'5"13**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 1-6-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS A11530ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Top chord may be notched 1.5" deep X 3.5"
at 48" o/c along top edge. DO NOT OVERCUT.
No knots or other lumber defects allowed within
12" of notches. Do not notch in overhang, (NNL),
or heel (first) panels.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*134 /-/-/45 /26 /7
Wind reactions based on MWFRS
B Brg Width = 204 Min Req =-
Bearing B is a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.03 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.002 H 999 360
VERT(CL):0.002 Y 999 240
HORZ(LL):-0.001 D - -
HORZ(TL):0.002 D - -
Creep Factor: 2.0
Max TC CSI:0.326
Max BC CSI:0.055
Max W eb CSI:0.043
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:A 17' GE
Ply: 1
Qty:2
SEQN:762689 T2 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1612.41400
CY /GWH 01/21/2019
A
B
H
N
O
5
12
2X4(A1T)
3X5
2X4(A1T)
17'
2'8"1'4"
(TYP)
8'6"
8'6"
17'
8'6"
17'
17'1'6"1'6"
4"13'10"94'5"1301/21/2019
WA COA #1931
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B 870 /-/-/369 /132 /77
F 870 /-/-/369 /132 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req =1.5
F Brg Width = 5.5 Min Req =1.5
Bearings B & F are a rigid surface.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - C 216 -1437
C - D 164 -1012
Chords Tens.Comp.
D - E 164 -1012
E - F 215 -1437
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - H 1289 -144
Chords Tens.Comp.
H - F 1289 -154
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - H 107 -495
D - H 490 -43
Webs Tens.Comp.
H - E 107 -495
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.03 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: Yes
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.042 H 999 360
VERT(CL):0.069 H 999 240
HORZ(LL):0.016 H - -
HORZ(TL):0.027 H - -
Creep Factor: 2.0
Max TC CSI:0.292
Max BC CSI:0.619
Max W eb CSI:0.212
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:A1 17' COM
Ply: 1
Qty:8
SEQN:762686 T1 COMN
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1612.43953
CY /GWH 01/21/2019
A
B
C
D
E
F
G
H
5
12
3X5(A1T)
2X4
4X4
4X8
2X4
3X5(A1T)
17'
4'6"14
4'6"14
8'6"
3'11"2
12'5"2
3'11"2
17'
4'6"14
8'6"
8'6"
17'
8'6"1'6"1'6"
4"13'10"94'5"13**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B 870 /-/-/369 /132 /77
F 870 /-/-/369 /132 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req =1.5
F Brg Width = 5.5 Min Req =1.5
Bearings B & F are a rigid surface.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - C 216 -1437
C - D 164 -1012
Chords Tens.Comp.
D - E 164 -1012
E - F 215 -1437
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - H 1289 -144
Chords Tens.Comp.
H - F 1289 -154
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - H 107 -495
D - H 490 -43
Webs Tens.Comp.
H - E 107 -495
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.03 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: Yes
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.042 H 999 360
VERT(CL):0.069 H 999 240
HORZ(LL):0.016 H - -
HORZ(TL):0.027 H - -
Creep Factor: 2.0
Max TC CSI:0.292
Max BC CSI:0.619
Max W eb CSI:0.212
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:A1 17' COM
Ply: 1
Qty:8
SEQN:762686 T1 COMN
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1612.43953
CY /GWH 01/21/2019
A
B
C
D
E
F
G
H
5
12
3X5(A1T)
2X4
4X4
4X8
2X4
3X5(A1T)
17'
4'6"14
4'6"14
8'6"
3'11"2
12'5"2
3'11"2
17'
4'6"14
8'6"
8'6"
17'
8'6"1'6"1'6"
4"13'10"94'5"1301/21/2019
WA COA #1931
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2: :T2 2x6
DF-L 1950f-1.7E:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Plating Notes
All plates are 2X4 except as noted.
(**) 1 plate(s) require special positioning. Refer to
scaled plate plot details for special positioning
requirements.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS A11530ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Special loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 65 plf at -1.50 to 65 plf at 26.00
TC: From 35 plf at 0.00 to 45 plf at 7.82
TC: From 45 plf at 7.82 to 45 plf at 12.25
TC: From 45 plf at 12.25 to 35 plf at 16.00
BC: From 4 plf at -1.50 to 4 plf at 0.00
BC: From 20 plf at 0.00 to 20 plf at 24.50
BC: From 4 plf at 24.50 to 4 plf at 26.00
T2: Brace all exposed vertical surfaces for lateral
wind forces. Brace interior top chord with nailer
or sistered truss at edge of lower roof diaphragm.
All diaphragms, braces, and connections shall
be designed by the engineer of record.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*258 /-/-/80 /56 /13
P 1104 /-/-/390 /190 /-
U /-166
Wind reactions based on MWFRS
B Brg Width = 95.5 Min Req =-
P Brg Width = 5.5 Min Req =1.5
Bearings B & P are a rigid surface.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - K 111 -413
K - N 106 -407
Chords Tens.Comp.
N - O 318 -1706
O - P 405 -1875
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
T - S 2072 -366
S - R 2072 -366
Chords Tens.Comp.
R - P 1677 -309
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
T -AB 439 -2064
AB- R 165 -566
AB- N 325 -1486
Webs Tens.Comp.
R - N 470 -72
R - O 148 -466
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.82 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.072 L 999 360
VERT(CL):0.114 L 999 240
HORZ(LL):0.030 R - -
HORZ(TL):0.048 R - -
Creep Factor: 2.0
Max TC CSI:0.288
Max BC CSI:0.759
Max W eb CSI:0.242
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:B 24'6" STD COM
Ply: 1
Qty:2
SEQN:762698 T5 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1614.59353
CY /GWH 01/21/2019
T2
A
B
K
N
O
P
Q
RSTU
AB
5
12
2X4(A1T)3X5
2X4(**)
3X5
3X5 4X8
4X8
3X5(A1T)
24'6"
2'8"1'4"
(TYP)
6'11"8
6'11"8
12'3"
5'3"8
16'
3'9"
20'1"6
4'1"6
24'6"
4'4"10
16'
16'
24'6"
8'6"1'6"1'6"
4"13'9"125'5"56'0"9**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2: :T2 2x6
DF-L 1950f-1.7E:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Plating Notes
All plates are 2X4 except as noted.
(**) 1 plate(s) require special positioning. Refer to
scaled plate plot details for special positioning
requirements.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS A11530ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Special loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 65 plf at -1.50 to 65 plf at 26.00
TC: From 35 plf at 0.00 to 45 plf at 7.82
TC: From 45 plf at 7.82 to 45 plf at 12.25
TC: From 45 plf at 12.25 to 35 plf at 16.00
BC: From 4 plf at -1.50 to 4 plf at 0.00
BC: From 20 plf at 0.00 to 20 plf at 24.50
BC: From 4 plf at 24.50 to 4 plf at 26.00
T2: Brace all exposed vertical surfaces for lateral
wind forces. Brace interior top chord with nailer
or sistered truss at edge of lower roof diaphragm.
All diaphragms, braces, and connections shall
be designed by the engineer of record.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*258 /-/-/80 /56 /13
P 1104 /-/-/390 /190 /-
U /-166
Wind reactions based on MWFRS
B Brg Width = 95.5 Min Req =-
P Brg Width = 5.5 Min Req =1.5
Bearings B & P are a rigid surface.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - K 111 -413
K - N 106 -407
Chords Tens.Comp.
N - O 318 -1706
O - P 405 -1875
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
T - S 2072 -366
S - R 2072 -366
Chords Tens.Comp.
R - P 1677 -309
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
T -AB 439 -2064
AB- R 165 -566
AB- N 325 -1486
Webs Tens.Comp.
R - N 470 -72
R - O 148 -466
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.82 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.072 L 999 360
VERT(CL):0.114 L 999 240
HORZ(LL):0.030 R - -
HORZ(TL):0.048 R - -
Creep Factor: 2.0
Max TC CSI:0.288
Max BC CSI:0.759
Max W eb CSI:0.242
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:B 24'6" STD COM
Ply: 1
Qty:2
SEQN:762698 T5 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1614.59353
CY /GWH 01/21/2019
T2
A
B
K
N
O
P
Q
RSTU
AB
5
12
2X4(A1T)3X5
2X4(**)
3X5
3X5 4X8
4X8
3X5(A1T)
24'6"
2'8"1'4"
(TYP)
6'11"8
6'11"8
12'3"
5'3"8
16'
3'9"
20'1"6
4'1"6
24'6"
4'4"10
16'
16'
24'6"
8'6"1'6"1'6"
4"13'9"125'5"56'0"901/21/2019
WA COA #1931
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B 1151 /-/-/503 /189 /100
F 1151 /-/-/503 /189 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req =1.5
F Brg Width = 5.5 Min Req =1.5
Bearings B & F are a rigid surface.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - C 618 -2059
C - D 585 -1811
Chords Tens.Comp.
D - E 585 -1811
E - F 617 -2059
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - J 1847 -484
J - I 1236 -272
Chords Tens.Comp.
I - H 1236 -272
H - F 1847 -493
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - J 209 -488
J - D 700 -162
Webs Tens.Comp.
D - H 700 -162
H - E 209 -488
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.82 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.091 J 999 360
VERT(CL):0.150 J 999 240
HORZ(LL):0.032 H - -
HORZ(TL):0.054 H - -
Creep Factor: 2.0
Max TC CSI:0.527
Max BC CSI:0.648
Max W eb CSI:0.264
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:B1 24'6" COM
Ply: 1
Qty:28
SEQN:762692 T4 COMN
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1615.00977
CY /GWH 01/21/2019
A
B
C
D
E
F
G
HIJ
5
12
3X5(A1T)
2X4
4X4
4X5
3X5 4X4
2X4
3X5(A1T)
24'6"
6'5"6
6'5"6
12'3"
5'9"10
18'0"10
5'9"10
24'6"
6'5"6
8'4"10
8'4"10
16'1"6
7'8"13
24'6"
8'4"101'6"1'6"
4"15'5"56'0"9**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B 1151 /-/-/503 /189 /100
F 1151 /-/-/503 /189 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req =1.5
F Brg Width = 5.5 Min Req =1.5
Bearings B & F are a rigid surface.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - C 618 -2059
C - D 585 -1811
Chords Tens.Comp.
D - E 585 -1811
E - F 617 -2059
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - J 1847 -484
J - I 1236 -272
Chords Tens.Comp.
I - H 1236 -272
H - F 1847 -493
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - J 209 -488
J - D 700 -162
Webs Tens.Comp.
D - H 700 -162
H - E 209 -488
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.82 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.091 J 999 360
VERT(CL):0.150 J 999 240
HORZ(LL):0.032 H - -
HORZ(TL):0.054 H - -
Creep Factor: 2.0
Max TC CSI:0.527
Max BC CSI:0.648
Max W eb CSI:0.264
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:B1 24'6" COM
Ply: 1
Qty:28
SEQN:762692 T4 COMN
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1615.00977
CY /GWH 01/21/2019
A
B
C
D
E
F
G
HIJ
5
12
3X5(A1T)
2X4
4X4
4X5
3X5 4X4
2X4
3X5(A1T)
24'6"
6'5"6
6'5"6
12'3"
5'9"10
18'0"10
5'9"10
24'6"
6'5"6
8'4"10
8'4"10
16'1"6
7'8"13
24'6"
8'4"101'6"1'6"
4"15'5"56'0"901/21/2019
WA COA #1931
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Plating Notes
All plates are 2X4 except as noted.
(**) 1 plate(s) require special positioning. Refer to
scaled plate plot details for special positioning
requirements.
Loading
Truss designed to support 1-6-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS A11530ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Top chord may be notched 1.5" deep X 3.5"
at 48" o/c along top edge. DO NOT OVERCUT.
No knots or other lumber defects allowed within
12" of notches. Do not notch in overhang, (NNL),
or heel (first) panels.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*138 /-/-/53 /25 /11
AB*122 /-/-/52 /28 /-
Wind reactions based on MWFRS
B Brg Width = 174 Min Req =-
AB Brg Width = 120 Min Req =-
Bearings B & AB are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.82 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.002 K 999 360
VERT(CL):0.002 AK 999 240
HORZ(LL):-0.001 E - -
HORZ(TL):0.002 G - -
Creep Factor: 2.0
Max TC CSI:0.326
Max BC CSI:0.059
Max W eb CSI:0.058
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:B2 24'6" GE
Ply: 1
Qty:2
SEQN:762695 T6 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1615.25370
CY /GWH 01/21/2019
A
B
K
T
U
AB
5
12
2X4(A1T)
2X4(**)
3X5
5X5 2X4(A1T)
24'6"
2'8"1'4"
(TYP)
12'3"
12'3"
24'6"
12'3"
24'6"
24'6"1'6"1'6"
4"15'5"56'0"9**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Plating Notes
All plates are 2X4 except as noted.
(**) 1 plate(s) require special positioning. Refer to
scaled plate plot details for special positioning
requirements.
Loading
Truss designed to support 1-6-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS A11530ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Top chord may be notched 1.5" deep X 3.5"
at 48" o/c along top edge. DO NOT OVERCUT.
No knots or other lumber defects allowed within
12" of notches. Do not notch in overhang, (NNL),
or heel (first) panels.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*138 /-/-/53 /25 /11
AB*122 /-/-/52 /28 /-
Wind reactions based on MWFRS
B Brg Width = 174 Min Req =-
AB Brg Width = 120 Min Req =-
Bearings B & AB are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.82 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.002 K 999 360
VERT(CL):0.002 AK 999 240
HORZ(LL):-0.001 E - -
HORZ(TL):0.002 G - -
Creep Factor: 2.0
Max TC CSI:0.326
Max BC CSI:0.059
Max W eb CSI:0.058
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:B2 24'6" GE
Ply: 1
Qty:2
SEQN:762695 T6 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1615.25370
CY /GWH 01/21/2019
A
B
K
T
U
AB
5
12
2X4(A1T)
2X4(**)
3X5
5X5 2X4(A1T)
24'6"
2'8"1'4"
(TYP)
12'3"
12'3"
24'6"
12'3"
24'6"
24'6"1'6"1'6"
4"15'5"56'0"901/21/2019
WA COA #1931
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 DF-L 1800f-1.6E
Bot chord 2x4 DF-L 1800f-1.6E
Webs 2x4 HF Stud :W2, W4, W5, W7 2x4 DF-L(N)
#1/#2 + DF-L #2:
Loading
Truss passed check for 20 psf additional bottom
chord live load in areas with 42"-high x 24"-wide
clearance.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B 2030 /-/-/856 /-/175
H 2031 /-/-/856 /-/-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req =2.2
H Brg Width = 5.5 Min Req =2.2
Bearings B & H are a rigid surface.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - C 443 -4210
C - D 457 -4032
D - E 406 -3162
Chords Tens.Comp.
E - F 406 -3163
F - G 457 -4034
G - H 443 -4212
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - O 3810 -333
O - N 3208 -253
N - M 3208 -253
M - L 2403 -151
Chords Tens.Comp.
L - K 3209 -270
K - J 3209 -270
J - H 3811 -348
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
O - D 696 -60
D - M 152 -823
M - E 1122 -100
Webs Tens.Comp.
E - L 1123 -100
L - F 152 -823
F - J 697 -61
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: h to 2h
C&C Dist a: 4.10 ft
Loc. from endwall: not in 13.00 ft
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.333 L 999 360
VERT(CL):0.528 L 925 244
HORZ(LL):0.118 J - -
HORZ(TL):0.188 J - -
Creep Factor: 2.0
Max TC CSI:0.809
Max BC CSI:0.834
Max W eb CSI:0.718
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:C 41' COM
Ply: 1
Qty:4
SEQN:762702 T10 COMN
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1615.29930
CY /GWH 01/21/2019
W2
W4
W5
W7
A
B
C
D
E
F
G
H
I
JKLMNO
5 12
3X10(B1T)
2X4
4X4 H0308
6X6
4X4
6X6
4X4
6X6
H0308 4X4
2X4
3X10(B1T)
41'
7'3"3
7'3"3
13'3"10
6'0"6
20'6"
7'2"6
27'8"6
7'2"6
33'8"13
6'0"6
41'
7'3"3
8'7"1
8'7"1
16'6"6
7'11"4
24'5"10
7'11"4
32'4"15
7'11"4
41'
8'7"11'6"1'6"
4"18'10"99'5"13**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 DF-L 1800f-1.6E
Bot chord 2x4 DF-L 1800f-1.6E
Webs 2x4 HF Stud :W2, W4, W5, W7 2x4 DF-L(N)
#1/#2 + DF-L #2:
Loading
Truss passed check for 20 psf additional bottom
chord live load in areas with 42"-high x 24"-wide
clearance.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B 2030 /-/-/856 /-/175
H 2031 /-/-/856 /-/-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req =2.2
H Brg Width = 5.5 Min Req =2.2
Bearings B & H are a rigid surface.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - C 443 -4210
C - D 457 -4032
D - E 406 -3162
Chords Tens.Comp.
E - F 406 -3163
F - G 457 -4034
G - H 443 -4212
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - O 3810 -333
O - N 3208 -253
N - M 3208 -253
M - L 2403 -151
Chords Tens.Comp.
L - K 3209 -270
K - J 3209 -270
J - H 3811 -348
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
O - D 696 -60
D - M 152 -823
M - E 1122 -100
Webs Tens.Comp.
E - L 1123 -100
L - F 152 -823
F - J 697 -61
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: h to 2h
C&C Dist a: 4.10 ft
Loc. from endwall: not in 13.00 ft
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.333 L 999 360
VERT(CL):0.528 L 925 244
HORZ(LL):0.118 J - -
HORZ(TL):0.188 J - -
Creep Factor: 2.0
Max TC CSI:0.809
Max BC CSI:0.834
Max W eb CSI:0.718
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:C 41' COM
Ply: 1
Qty:4
SEQN:762702 T10 COMN
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1615.29930
CY /GWH 01/21/2019
W2
W4
W5
W7
A
B
C
D
E
F
G
H
I
JKLMNO
5 12
3X10(B1T)
2X4
4X4 H0308
6X6
4X4
6X6
4X4
6X6
H0308 4X4
2X4
3X10(B1T)
41'
7'3"3
7'3"3
13'3"10
6'0"6
20'6"
7'2"6
27'8"6
7'2"6
33'8"13
6'0"6
41'
7'3"3
8'7"1
8'7"1
16'6"6
7'11"4
24'5"10
7'11"4
32'4"15
7'11"4
41'
8'7"11'6"1'6"
4"18'10"99'5"1301/21/2019
WA COA #1931
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 DF-L 1800f-1.6E
Bot chord 2x4 DF-L 1800f-1.6E
Webs 2x4 HF Stud :M12, M13, M14, M15, M16 2x4
DF-L(N) #1/#2 + DF-L #2:
Bracing
(a) 1x4 #3 SPF-S or better "L" reinforcement. 80%
length of web member. Attach with 8d Box or Gun
nails (0.113"x2.5",min.) @ 6" OC.
Plating Notes
All plates are 2X4 except as noted.
(**) 2 plate(s) require special positioning. Refer to
scaled plate plot details for special positioning
requirements.
Loading
Truss designed to support 1-6-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord may be
notched 1.5" deep X 3.5" periodically along top
edge. DO NOT OVERCUT. No knots or other lumber
defects allowed within 12" of notches. Do not notch
in overhang or heel panel.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*138 /-/-/62 /20 /22
BD*124 /-/-/41 /10 /-
AQ*134 /-/-/61 /20 /-
Wind reactions based on MWFRS
B Brg Width = 144 Min Req =-
BD Brg Width = 204 Min Req =-
AQ Brg Width = 144 Min Req =-
Bearings B, BD, & AQ are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 4.10 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.002 Q 999 360
VERT(CL):0.004 Q 999 240
HORZ(LL):0.003 V - -
HORZ(TL):0.005 V - -
Creep Factor: 2.0
Max TC CSI:0.230
Max BC CSI:0.038
Max W eb CSI:0.125
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:C1 41' GE
Ply: 1
Qty:2
SEQN:762705 T11 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1615.47407
CY /GWH 01/21/2019
M12
M13
M14
M15
M16
(a)
(a)
A
B
K
Q
W
AG
AH
AQBD
5 12
3X5(A1T)
6X6
6X6
3X10
3X10(**)
3X10(**)3X5(A1T)
12'17'12'
2'8"1'4"
(TYP)
20'6"
20'6"
41'
20'6"
41'
41'1'6"1'6"
4"18'10"99'5"13**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 DF-L 1800f-1.6E
Bot chord 2x4 DF-L 1800f-1.6E
Webs 2x4 HF Stud :M12, M13, M14, M15, M16 2x4
DF-L(N) #1/#2 + DF-L #2:
Bracing
(a) 1x4 #3 SPF-S or better "L" reinforcement. 80%
length of web member. Attach with 8d Box or Gun
nails (0.113"x2.5",min.) @ 6" OC.
Plating Notes
All plates are 2X4 except as noted.
(**) 2 plate(s) require special positioning. Refer to
scaled plate plot details for special positioning
requirements.
Loading
Truss designed to support 1-6-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord may be
notched 1.5" deep X 3.5" periodically along top
edge. DO NOT OVERCUT. No knots or other lumber
defects allowed within 12" of notches. Do not notch
in overhang or heel panel.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*138 /-/-/62 /20 /22
BD*124 /-/-/41 /10 /-
AQ*134 /-/-/61 /20 /-
Wind reactions based on MWFRS
B Brg Width = 144 Min Req =-
BD Brg Width = 204 Min Req =-
AQ Brg Width = 144 Min Req =-
Bearings B, BD, & AQ are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 4.10 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.002 Q 999 360
VERT(CL):0.004 Q 999 240
HORZ(LL):0.003 V - -
HORZ(TL):0.005 V - -
Creep Factor: 2.0
Max TC CSI:0.230
Max BC CSI:0.038
Max W eb CSI:0.125
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:C1 41' GE
Ply: 1
Qty:2
SEQN:762705 T11 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1615.47407
CY /GWH 01/21/2019
M12
M13
M14
M15
M16
(a)
(a)
A
B
K
Q
W
AG
AH
AQBD
5 12
3X5(A1T)
6X6
6X6
3X10
3X10(**)
3X10(**)3X5(A1T)
12'17'12'
2'8"1'4"
(TYP)
20'6"
20'6"
41'
20'6"
41'
41'1'6"1'6"
4"18'10"99'5"1301/21/2019
WA COA #1931
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 1-6-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Top chord may be notched 1.5" deep X 3.5"
at 48" o/c along top edge. DO NOT OVERCUT.
No knots or other lumber defects allowed within
12" of notches. Do not notch in overhang, (NNL),
or heel (first) panels.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*132 /-/-/60 /43 /27
J 22 /-/-/8 /41 /-
Wind reactions based on MWFRS
B Brg Width = 118 Min Req =-
J Brg Width = 1.5 Min Req =1.5
Bearings B & J are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.001 P 999 360
VERT(CL):0.002 P 999 240
HORZ(LL):-0.004 H - -
HORZ(TL):0.005 H - -
Creep Factor: 2.0
Max TC CSI:0.326
Max BC CSI:0.056
Max W eb CSI:0.027
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:M 9'11"8 MONO GE
Ply: 1
Qty:2
SEQN:762715 T8 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1616.04210
CY /GWH 01/21/2019
A
B
I
J
5
12
2X4(A1T)
9'11"8
2'8"1'4"
(TYP)
9'10"
9'10"
9'11"8
1"8
1'6"
4"1 3"84'2"54'5"135'1"1**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 1-6-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Top chord may be notched 1.5" deep X 3.5"
at 48" o/c along top edge. DO NOT OVERCUT.
No knots or other lumber defects allowed within
12" of notches. Do not notch in overhang, (NNL),
or heel (first) panels.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*132 /-/-/60 /43 /27
J 22 /-/-/8 /41 /-
Wind reactions based on MWFRS
B Brg Width = 118 Min Req =-
J Brg Width = 1.5 Min Req =1.5
Bearings B & J are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.001 P 999 360
VERT(CL):0.002 P 999 240
HORZ(LL):-0.004 H - -
HORZ(TL):0.005 H - -
Creep Factor: 2.0
Max TC CSI:0.326
Max BC CSI:0.056
Max W eb CSI:0.027
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:M 9'11"8 MONO GE
Ply: 1
Qty:2
SEQN:762715 T8 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1616.04210
CY /GWH 01/21/2019
A
B
I
J
5
12
2X4(A1T)
9'11"8
2'8"1'4"
(TYP)
9'10"
9'10"
9'11"8
1"8
1'6"
4"1 3"84'2"54'5"135'1"101/21/2019
WA COA #1931
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B 405 /-/-/196 /31 /98
F 365 /-/-/194 /25 /-
E 201 /-/-/83 /40 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req =1.5
F Brg Width = 5.5 Min Req =1.5
E Brg Width = 1.5 Min Req =1.5
Bearings B, F, & E are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: Yes
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.016 F 999 360
VERT(CL):0.028 F 999 240
HORZ(LL):0.008 F - -
HORZ(TL):0.015 F - -
Creep Factor: 2.0
Max TC CSI:0.431
Max BC CSI:0.288
Max W eb CSI:0.088
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:M1 9'11"8 MONO
Ply: 1
Qty:8
SEQN:762712 T7 MONO
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1616.12657
CY /GWH 01/21/2019
A
B
C
D
EF
5 12
2X4(A1T)2X4
4X4
4X4
2X4
6'2"12 3'8"12
6'2"12
6'2"12
9'11"8
3'8"12
6'2"12
6'2"12
9'10"
3'7"4
9'11"8
1"81'6"
4"1 3"84'2"54'5"135'1"1**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B 405 /-/-/196 /31 /98
F 365 /-/-/194 /25 /-
E 201 /-/-/83 /40 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req =1.5
F Brg Width = 5.5 Min Req =1.5
E Brg Width = 1.5 Min Req =1.5
Bearings B, F, & E are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: Yes
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.016 F 999 360
VERT(CL):0.028 F 999 240
HORZ(LL):0.008 F - -
HORZ(TL):0.015 F - -
Creep Factor: 2.0
Max TC CSI:0.431
Max BC CSI:0.288
Max W eb CSI:0.088
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:M1 9'11"8 MONO
Ply: 1
Qty:8
SEQN:762712 T7 MONO
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1616.12657
CY /GWH 01/21/2019
A
B
C
D
EF
5 12
2X4(A1T)2X4
4X4
4X4
2X4
6'2"12 3'8"12
6'2"12
6'2"12
9'11"8
3'8"12
6'2"12
6'2"12
9'10"
3'7"4
9'11"8
1"81'6"
4"1 3"84'2"54'5"135'1"101/21/2019
WA COA #1931
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 1-6-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*147 /-/-/71 /84 /50
E 41 /-/-/12 /68 /-
Wind reactions based on MWFRS
B Brg Width = 46.0 Min Req =-
E Brg Width = 1.5 Min Req =1.5
Bearings B & E are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.001 F 999 360
VERT(CL):0.002 F 999 240
HORZ(LL):-0.001 D - -
HORZ(TL):0.001 F - -
Creep Factor: 2.0
Max TC CSI:0.326
Max BC CSI:0.053
Max W eb CSI:0.067
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:M2 3'11"8 MONO GE
Ply: 1
Qty:2
SEQN:762710 T13 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1616.17053
CY /GWH 01/21/2019
A
B
D
E
5
12
2X4(A1T)
3'11"8
2'8"
2'8"
3'11"8
1'3"8
2'8"
2'8"
3'10"
1'2"
3'11"8
1"8
1'6"
4"1 3"81'8"51'11"132'7"1**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 1-6-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN1014, &
GABRST101014 for gable wind bracing
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B*147 /-/-/71 /84 /50
E 41 /-/-/12 /68 /-
Wind reactions based on MWFRS
B Brg Width = 46.0 Min Req =-
E Brg Width = 1.5 Min Req =1.5
Bearings B & E are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: No
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):0.001 F 999 360
VERT(CL):0.002 F 999 240
HORZ(LL):-0.001 D - -
HORZ(TL):0.001 F - -
Creep Factor: 2.0
Max TC CSI:0.326
Max BC CSI:0.053
Max W eb CSI:0.067
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:M2 3'11"8 MONO GE
Ply: 1
Qty:2
SEQN:762710 T13 GABL
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1616.17053
CY /GWH 01/21/2019
A
B
D
E
5
12
2X4(A1T)
3'11"8
2'8"
2'8"
3'11"8
1'3"8
2'8"
2'8"
3'10"
1'2"
3'11"8
1"8
1'6"
4"1 3"81'8"51'11"132'7"101/21/2019
WA COA #1931
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B 299 /-/-/150 /31 /46
D 165 /-/-/67 /18 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req =1.5
D Brg Width = 1.5 Min Req =1.5
Bearings B & D are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: Yes
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):NA
VERT(CL):NA
HORZ(LL):0.003 D - -
HORZ(TL):0.005 D - -
Creep Factor: 2.0
Max TC CSI:0.231
Max BC CSI:0.142
Max W eb CSI:0.069
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:M3 3'11"8 MONO
Ply: 1
Qty:16
SEQN:762707 T12 MONO
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1616.19877
CY /GWH 01/21/2019
A
B
C
D
5
12
2X4(A1T)2X4
2X4
3'11"8
3'10"
3'10"
3'11"8
1"8
1'6"
4"1 3"81'8"51'11"132'7"1**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING!
**IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Tru-Truss, Inc.
2750 Hogum Bay Road, N.E.
LACEY WA 98516
(360) 491-8024 Ext
8351 Rovana Circle
Sacramento, CA 95828
Lumber
Top chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Bot chord 2x4 :DF-L(N) #1/#2 + DF-L #2:
Webs 2x4 HF Stud
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+/ R-/ Rh / Rw / U / RL
B 299 /-/-/150 /31 /46
D 165 /-/-/67 /18 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req =1.5
D Brg Width = 1.5 Min Req =1.5
Bearings B & D are a rigid surface.
Members not listed have forces less than 375#
Loading Criteria (psf)
TCLL:25.00
TCDL:7.00
BCLL:0.00
BCDL:10.00
Des Ld:42.00
NCBCLL:10.00
Soffit:2.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std:ASCE 7-10
Speed:110 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 3.5 psf
BCDL: 5.0 psf
MW FRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.33
Snow Criteria (Pg,Pf in PSF)
Pg: 25.0 Ct: -CAT: -
Pf: 25.0 Ce: -
Lu: -Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code:IRC 2015
TPI Std:2014
Rep Fac: Yes
FT/RT:20(0)/5(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL):NA
VERT(CL):NA
HORZ(LL):0.003 D - -
HORZ(TL):0.005 D - -
Creep Factor: 2.0
Max TC CSI:0.231
Max BC CSI:0.142
Max W eb CSI:0.069
VIEW Ver: 18.01.00C.0525.21
Job Number:KWN0118J
KW NORTHWEST
Truss Label:M3 3'11"8 MONO
Ply: 1
Qty:16
SEQN:762707 T12 MONO
FROM: JDS
Cust: R 7173 JRef:1WHY71730001
DrwNo:021.19.1616.19877
CY /GWH 01/21/2019
A
B
C
D
5
12
2X4(A1T)2X4
2X4
3'11"8
3'10"
3'10"
3'11"8
1"8
1'6"
4"1 3"81'8"51'11"132'7"101/21/2019
WA COA #1931
Earth City, MO 63045
13389 Lakefront Drive 01/21/2019
Earth City, MO 63045
13389 Lakefront Drive
01/21/2019
13723 Riverport Drive
Suite 200
Maryland Heights, MO 63043 01/21/2019
Earth City, MO 63045
13389 Lakefront Drive 01/21/2019