20190019 PLANS - LS2-2472-2R (2015 IRC) 4-5-18; < > > ; mm 4/Ox4K6 XO DW SINK KITCHEN 9' CEILING 100 CFM O E.F. VTOS O RANGE 4'-10" I REFER �F OPNG F �J -7 G.M.If- Vfj -- R45 -- tt 'n X 70 N -- o -- 2 ReS ¢ �r �r x Z_ pm �, 1=L,4YR00M 0 DINING B.F® O= 8' CEILING 0 RO 2 m - r � 1100 OPEN RAIL r Q ?STH S.D. R IRC I-1 / 2. VENT ALL EXHAUST FANS, DRYER VENTS AND RANGES TO OUTSIDES. 3. VENT WATER HEATER PRESSURE RELIEF VALVES TO OUTSIDE. 4. PROVIDE FIRE BLOCKING AT ALL PLUMBING AND MECHANICAL PENETRATIONS. 5. ALL SHOWER WALLS TO BE WATERPROOF TO MINIMUM -12" ABOVE DRAIN. 6. SHOWERHEADS 4 KITCHEN FAUCET TO BE LIMITED TO MAXIMUM 1.15 G.P.M. FLOW. ALL OTHER LAVATORY FAUCETS TO BE LIMITED TO MAXIMUM 1.0 G.P.M FLOW. 7. ALL GLAZING WITHIN 60" ABOVE DRAIN INLET TO BE SAFETY GLASS. 8. ALL GLAZING WITHIN 24" OF DOOR OR WITHIN 18" OF FLOOR TO BE SAFETY GLASS 9. SMOKE ALARMS - TO BE INSTALLED PER SEC 8314.3 IN THE FOLLOWING LOCATIONS: IN EACH SLEEPING ROOMS, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS, AND ALARMS TO BE INSTALLED NOT LESS THAN 3 FT. HORIZONTALLY FROM A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER. ALARMS TO BE INTERCONNECTED IN SUCH A MANNER THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. AS. ® - =SMOKE ALARM -CARBON MONOXIDE COMBO G.M. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED ON EACH FLOOR 8 OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. PER 2015 IRC 6 WA. STATE AMENDMENTS SEC 8315. 11. INSULATE ALL WATER PIPES TO MINIMUM R-3 PER WSEC 8403.5.3. 12. ALL DUCTS 8 EXHAUST DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-8 PER WSEC R403.3.1. DUCTS WITHIN A CONCRETE SLAB OR IN THE GROUND SHALL BE INSULATED TO R-10 WITH INSULATION DESIGNED TO BE USED BELOW GRADE. 13. EXHAUST AIR SHALL NOT BE DIRECTED ONTO WALKWAYS. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. PER R303.5.2. 14. GAS PIPING IS TO BE PROTECTED PER G24151. WHERE PIPING IS INSTALLED THROUGH HOLES OR NOTCHES IN FRAMING MEMBERS AND THE PIPING IS LOCATED LESS THAN 1-1/2 INCHES FROM THE FRAMING MEMBER FACE TO WHICH WALL, CEILING OR FLOOR MEMBRANES WILL BE ATTACHED, THE PIPE SHALL BE PROTECTED BY SHIELD PLATES THAT COVER THE WIDTH OF THE PIPE AND THE FRAMING MEMBER AND THAT EXTEND NOT LESS THAN 4 INCHES TO EACH SIDE OF THE FRAMING MEMBER. WHERE THE FRAMING MEMBER THAT THE PIPING PASSES THROUGH IS A BOTTOM PLATE, BOTTOM TRACK, TOP PLATE OR TOP TRACK, THE SHIELD PLATES SHALL COVER THE FRAMING MEMBER AND EXTEND NOT LESS THAN 4 INCHES ABOVE THE BOTTOM FRAMING MEMBER AND NOT LESS THAN 4 INCHES BELOW THE TOP FRAMING MEMBER. z m 36" 30 LA DING 6/Ox8 O SGD s.G. NOOK 9' CEILING FLOORING TRANSITION 4' -OP 5'-9" i I Poo 0 GO ERE1� n P RGH ONC. 8 LANDING AT "EXIT" DOOR NOT TO BE LOWER THAN 1.5 INCHES FROM TOP OF I' -8J. " 2'-10" 2'-10" 1'-8" THRESHOLD. (8311.3.1) 9'-0" 4TCHE5 OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES 16. WHOLE HOUSE VENTILATION 24 HR TIMER, READILY ACCESSIBLE 8 WITH LABEL AFFIXED TO CONTROL THAT READS "WHOLE HOUSE VENTILATION" (SEE OPERATING INSTRUCTIONS) 1-1. DRYER DUCT SPECIFIED LENGTH PER SEC M1502.4.5.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET(10.6(o8mm) FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH THE TABLE M1502.4.5.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. 18. CAVITIES WITHIN CORNERS AND HEADERS OF FRAME WALLS SHALL BE INSULATED BY COMPLETELY FILLING THE CAVITY WITH A MATERIAL HAVING A THERMAL RESISTANCE OF R-3 PER INCH MINIMUM PER 2015 WSEC TABLE 8402.4.1.1. 24 P D 50 CF MI 2/0>45/0 �z 4'-3" L 3'-6A I A1 -311 " 12'-0 L �F 0 6/0x6/® XO '-4 GREAT 9' CEILING DIRECT VENT NATURAL CTAS METAL FIREPLACE INSTALL PER MFR SPECS. PROVIDE 6" SQ. IN. OUTSIDE AIR 19'-2" ER STAIR v OTECT I ON R3021 EN E E5515LE S W/ 1/2" G.W.B. 19'-O" GARAGE USE 1/2" GWB ON ALL WARM AND STRUCTURAL WALLS. (1) LAYER 5/8" TYPE "X" ON CEILINGS. WRAP ALL EXPOSED POSTS AND BEAMS IN 1/2" GWB NO DUCT OPENINGS IN GARAGE. DUCTS THROUGH CLCD OR 6i WALL COMMON TO HOUSE, MIN. 26 GAGE STEEL. - - - - r- - - - - - - I I I I FLOOR LINE ABOVE L- - - - - - - - - -- m 16/0x8/0 O.H� DOOR 16'-3" R.O. 4X4 PT POST WRAPPED TO TAPERED COLUMN w/ 20" SQ. BASE (3) PLACES 9'-0 7O7AL REAR FORTH �RON7 f=OR(f,,H UTILITY ROOM NOTES/MAKE UP AIR: PER IRC G2439 I. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION AND THE EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS 35 FT., THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT OF THE EXHAUST DUCT CONNECTION PER G24391.5. 2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED WITH MAKE UP AIR. WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR. MEANS PER G2439.5. C ::i = 100 SQ INCH TRANSFER GRILL 9' 11 -0 0 0 r m i BLUE 18 AWG TRACER WIRE REQUIRED AT NON- METAL WATER SERVICE PIPING PER UPC 604.9 INTERIOR STAIRWAY ILLUMINATION PER SEC 8303.7 IRC INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN 1 FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS PROVIDED. EXTERIOR STAIRWAY ILLUMINATION PER SEC 8303.8 IRC EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. ZCD oh Ch 50.fi. 50. �fi. ®® 50.fi. ❖ zM 155 50.1::7. 100O.fi. 0 r m i BLUE 18 AWG TRACER WIRE REQUIRED AT NON- METAL WATER SERVICE PIPING PER UPC 604.9 INTERIOR STAIRWAY ILLUMINATION PER SEC 8303.7 IRC INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN 1 FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS PROVIDED. EXTERIOR STAIRWAY ILLUMINATION PER SEC 8303.8 IRC EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. ZCD oh Ch ❖ zM A A� E 2 yv aN � o 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. Plan No: LS2-2472-2R Date: 3-20-18 fiJ AFFO-111111rol MIN. 2" AIR SPACE 4" CONC. SLAB PREVENT WOOD TO CONC. CONTACT W/ CONT. FLASHING OR APPROVED MEMBRANE STUB 1*4 BARS INTO GONG. SLAB a IS" O.G. FOUNDATION NOTES: I. ALL FOOTINGS TO BEAR ON FIRM UNDISTUR5ED SOIL. 2. ALL WOOD IN CONTACT WITH CONCRETE TO 5E PRESSURE TREATED. 3. ALL BEAMS TO 5E 4x10 DFL *2 ON 4x4 POSTS (4x6 AT SPLICES) ON 24" DIA. x 5" CONC. PADS UNLESS NOTED OTHERWISE. 4. ALL POSTS TO 5E ANCHORED AGAINST LATERAL MOVEMENT. 5. SOLID BLOCK AT ALL POINT LOADS FROM ABOVE. 6. FLOOR JOISTS SHOULD 5E SUPPORTED LATERALLY AT EACH END AND AT EACH SUPPORT, 5Y SOLID 5LOCKING OR 5Y ANOTHER APPROVED METHOD. 1. PROVIDE MINIMUM IS" -24" CRAWL ACCESS. *CRAWL ACCESS HATCHES OR DOORS SHALL 5E WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. 5. PROVIDE CRAWL SPACE VENTILATION PER IRC SECTION R405. *FOUNDATION VENTS SHALL 5E PLACED SO THAT THE TOP OF THE VENT IS BELOW THE LOWER SURFACE OF THE FLOOR INSULATION. 9. INTERIOR GRADE OF CRAWL SPACE SHALL 5E SLOPED TO DRAIN AND INSURE THE REMOVAL OF WATER. 10.PREVENT WOOD TO CONC. CONTACT W/CONT. FLASHING OR APPROVE MEMBRANE. II. INDICATES 'SIMPSON' HOLDDOWN. 12. aSEE SHEARWALL SCHEDULE FOR ANCHOR BOLT SIZE SPACING (SHT 51.0). ZCD oh Ch ❖ zM 02 ♦ - ER yv �j F-+ Q) za •° -M a � o N .r 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. Plan No: LS2-2472-2R F_ Date: 4-5-18 APPLIANCES IN ATI PER 2015 IRC M1305.1.3 I. ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, BUT NOT LESS THAN 30 INCHES HIGH AND 22 INCHES WIDE AND NOT MORE THAN 20 FT LONG MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH CHAPTER 5 NOT LESS THAN 24 INCHES WIDE. A LEVEL SERVICE SPACE NOT LESS THAN 30 INCHES DEEP AND 30 INCHES WIDE SHALL BE PRESENT ALONG ALL SIDES OF THE APPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR ACCESS OPENING DIMENSIONS SHALL BE NOT LESS THAN OF 20 INCHES BY 30 INCHES, AND LARGE ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE. EXCEPTIONS: 1. THE PASSAGEWAY AND LEVEL SERVICE SPACE ARE NOT REQUIRED WHERE THE APPLIANCE CAN BE SERVICED AND REMOVED THROUGH THE REQUIRED OPENING. 2. WHERE THE PASSAGEWAY IS UNOBSTRUCTED AND NOT LESS THAN 6 FT HIGH AND 22 INCHES WIDE FOR ITS ENTIRE LENGTH, THE PASSAGEWAY SHALL BE NOT MORE THAN 5O FT LONG. 2. ELECTRICAL REQUIREMENTS M1305.1.3.1. A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN ACCORDANCE WITH CHAPTER 39. EXPOSED LAMPS SHALL BE PROTECTED FROM DAMAGE BY LOCATION OR LAMP GUARDS. 3. PROVIDE 2x12 PLATFORM W/ 2-LAYER5 394" PLYWOOD ATOP BOTTOM CHORD OF MFG. TRUSS THAT MEETS THE REQUIRED CLEARANCES. USE R-49 INSULATION UNDER PLATFORM. (1 -LAYER OF R-38 HIGH DENSITY (10-1/4") 4 I -LAYER R-11 (3-1/2"). 4. NO AIR CONDITIONING TO BE INSTALLED IN ATTIC. 5. PROVIDE GALVANIZED MT. DRAIN PAN WITH WET SWITCH. PROVIDE CONDENSATION LINE FROM FURNACE TO EXTERIOR FOR DRAINAGE. 6. SOLID FUEL -BURNING APPLIANCES SHALL BE PROVIDED WITH COMBUSTION AIR IN ACCORDANCE WITH THE APPLIANCE MANUFACTURER'S INSTALLATION INSTRUCTIONS PER IRC M1-101.1. -1. FOLLOW MANUFACTURER'S INSTALLATION TO PLATFORM FOR SEISMIC SUPPORT. i_�. � � i x 1= i v i i r_ 1 -IN i i %_� i v %s r -e r_ %s �..r r_ r --e i i '_� i N %s 1+ 1_*� L__ vc 11 r i 1-1 1= 1 1L__ i Nk i * J/ AT LEAST 409.4 NOT MORE THAN 50% OF REQUIRED VENTS SHALL BE IN UPPER PORTION OF VENTILATED ROOF SPACE (NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT) WITH THE BALANCE OF REQUIRED VENTILATION PROVIDED BY EAVE VENTING. VENTILATION REQUIRED PER SEC. R806.1 - ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE GROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSIONS OF 1/16" INCH MINIMUM AND 1/4" INCH MAXIMUM. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED WITH CORROSION -RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF 1/16" MINIMUM AND 1/4" MAXIMUM. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQUIREMENTS OF SECTION 88021. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR. MINIMUM VENT AREA PER SEC. 8806.2 - THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE. VENT AND INSULATION CLEARANCE PER SEC. RSO6.3 - WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. NOT LESS THAN A I -INCH SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AND AT THE LOCATION OF THE VENT. SEE SHEET N2 FOR ROOF VENTILATION CALCULATIONS AND LOCATIONS LSTA36 - HDR 4 SILL L5TA36 - HDR 4 SILL TO 3x BLOCKING._ �I? PTO 3x BLOCKING._ 11 11(TYR ? Ri Ar=S> (TYF= i arms � 8 (TYP. 2 PLACES) S2.O ROOF OVERFRAME NOTES: IRC SEC R802.3 I. RAFTERS SHALL BE FRAMED TO 2x RIDGE BOARD PER PLAN. RIDGE BOARD SHALL NOT BE LESS IN DEPTH THAN THE CUT END OF THE RAFTER. AT ALL VALLEYS AND HIPS THERE SHALL BE A 2x VALLEY OR HIP RAFTER AND NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER. (FULL COVERAGE AT RIDGE, HIPS AND VALLEYS). ROOF FRAMING NOTES: I. ALL HEADERS TO BE 4x8 DF 02, UNLESS NOTED OTHERWISE. HEADERS AT EXTERIOR WALLS 4 WARM WALLS TO BE INSULATED W/R-10 RIGID INSULATION. 2. ALL OTHER TRUSSES: * SHALL CARRY MANUFACTURERS STAMP. * SHALL HAVE DESIGN DETAILS AND SPECIFICATIONS ON SITE FOR FRAME INSPECTION. * SHALL BE INSTALLED AND BRACED PER MANUFACTURERS SPEC IFIGATIONS. 3. NO TRUSS SHALL BE FIELD -MODIFIED WITHOUT PRIOR CONSENT OF THE TRUSS ENGINEER AND THE BUILDING DEPARTMENT. 4. PROVIDE ATTIC ACCESS AT A MINIMUM OF 22"x3O' PER IRC SEC. RSO7.1. *ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. 5. PROVIDE ATTIC VENTILATION PER IRC SEC. 8806. ALL FRAMING TO COMPLY WITH IRC SEC 8802. 6. \ REFER TO SHEAR WALL SCHEDULE. /.411=11-011 411=11_011 ;ONT. DBL. TOP PLATE HEADER/INSULATION DETAIL NTS FRAMING NOTES: I. ALL MULTIPLE JOISTS OR BEAMS MUST BE BOTH GLUED AND NAILED W/Sd NAILS a 24" O.C. NAILED TOP 4 BOTTOM STAGGERED EACH SIDE. 2. ALL HEADERS TO BE 4x8 DF *2, UNLESS Z-10 RIGID INSULATION NOTED OTHERWISE. HEADERS AT EXTERIOR D EXTERIOR SIDE OF WALL WALLS 4 WARM WALLS TO BE INSULATED SHADED AREA) W/R-10 RIGID INSULATION. 4X HEADER 3. SOLID BLOCK BENEATH ALL POINT LOADS FROM ABOVE. 4. FLOOR JOISTS SHOULD BE SUPPORTED LATERALLY AT EACH AND AT EACH SUPPORT BY SOLID BLOCKING OR BY ANOTHER KING STUD APPROVED METHOD. EXTERIOR PLYWOOD 5. MSTC 40 STRAPS PER STRUCTURAL, UNLESS NOTED OTHERWISE TRIMMER 6. \ REFER TO SHEAR WALL SCHEDULE. ZCD oh Ch ❖ zM A! 02 ♦ ER •e• rr7 � yv �j F-+ Q) za •° -M aN � o 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. Plan No: LS2-2472-2R F_ Date: 4-5-18 �I v 2x6 1'2 OF STUDS 6 16' O.C. ATTACH STUDS TO TOP 4 BOTTOM PLATE (3) 16d FRAMING NAILS. CONSTRUCT TOP PLATE OF (2) STUDS INSTALLED HORIZ. AT THE TOP OF THE G WALL ASSEMBLY AND THE BOTTOM PLA A SINGLE STUD. INSTALL 2x6 WOOD STUC HORIZ. AS GROSS -BRACING POSITIONED MID -HEIGHT OF THE WALL. V TYPE 'X' GWB APPLIED VERTICALLY W/ HORIZONTAL JOINTS BLOCKED AND FASTENED W/6d CEMENT COATED 1l/8' CUP -HEAD DRYWALL NAILS W/.0915' SHANK DIA. 4 1/4' HEAD DIA. SPACED 6' O.C. ALONG STUDS 4 PLATES. EXPOSED FASTENER HEADS AND WALLBOARD JOINTS MUST BE TREATED W/(2) COATS OF GYPSUM COMPOUND. A MIN. 2' PAPER PLASTIC OR FIBERGLASS TAPE MUST BE EMBEDDED IN FIRST LAYER OF COUMPOUND OVER WALLBOARD JOINTS. SOLID TIGHT FITTING TRUSS BLOCKING (SEE DETAIL THIS SHEET FOR EAVE VENTING) 2X8 FASCIA BOARD 7%' LP® FLAMEBLOCK® FIRE -RATED OSB SHEATHING W/1.5mm PYROTITE LAMINATE APPLIED TO ONLY ONE FACE OF WOOD PANEL. SHEATHING MUST BE INSTALLED VERTICALLY W/HORIZONTAL JOINTS BLOCKED 4 W/PYROTITE LAMINATE FACING THE OUTSIDE 4 MUST BE ATTACHED TO THE STUDS W/11/8' 6d COMMON NAILS SPACED 6' O.G. AROUND PERIMETER 4 12' O.0 IN THE FIELD. 51/2' THICK NOMINAL 3 PGF DENSITY UNFACED MINERAL FIBER BATT INSULATION FRICTION FIT BETWEEN THE WOOD STUDS, GROSS -BRACING 4 TOP/BOTTOM PLATES. WEATHER BARRIER FASTENED OVER THE SHEATHING USING SUFFICIENT FASTENERS TO PREVENT AIR POCKETS IN THE WRAP EXTERIOR WALL COVERING: I. FIBER CEMENT BOARD 2. Tl -I1 SIDING 3. WOOD FIBER PANEL 4. CEMENT PLASTER (STUCCO) 5. STEEL SIDING DESIGN: (ICC -ES REPORT - ESR -136 5) WALL TYPE 4.3.4 - 1 HR EXTERIOR WALL ASSEMBLY FIRE BLOCKING AND DRAFTSTOPPINI PER SECTION 8302.11 • R302.12 I. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR STAGGERED STUD: FOLLOWS: A. VERTICALLY AT THE CEILING 4 FLOOR LEVELS B. HORIZONTALLY AT INTERVALS NOT EXCEEDING 2. AT ALL INTERCONNCECTIONS BETWEEN CONCEALEI VERTICAL AND HORIZONTAL SPACES SUCH AS OC( AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. 3. IN CONCEALED SPACES AT STAIR STRINGERS AT T TOP AND BOTTOM OF THE RUN. ENCLOSED SPACE: UNDER STAIRS SHALL COMPLY WITH SEC. 83021. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CARL AND WIRES AT CEILING AND FLOOR LEVEL, WITH Al' APPROVED MATERIAL TO RESIST THE FREE PASS OF FLAME AND PRODUCTS OF COMBUSTION. EAVES 4 WALL WITHIN 5'-0' OF PROPERTY LINE PER IRC 302 4 TABLE 8302.1 NO SCALE HOUR FIRE-RE51571\/E DETAILS W1 IN 3ro" MIN. 6x6 PT POST V LP® FLAMEBLOCKO FIRE -RATED DSB SHEATHING �)R No' TYPE 'X' GWB SHEATHING SIDING OR TRIM PER PLAN POST DETAIL FOR STRUCTURES LESS THAN 5' FROM PROPERTY LINE AF50 ROOF VENTS (50 SQ. IN. NET FREE AREA) SOLID TIGHT FITTING TRUSS BLOCKING 2x8 FASCIA BOARD 2x STUDS PER PLAN 7W6' SHEATHING EXTERIOR WALL COVERING PER PLAN EAVES WITHIN 5'-0' OF PROPERTY LINE PER IRC 302 4 TABLE 8302.1 STAIR NOTES: PER IRC 8311.1 • STRINGERS TO BE FIRE BLOCKED AT BOTH TOP AND BOTTOM. • ALL USABLE SPACE UNDER STAIRS TO BE 1 HOUR 4' SPHERE SHALL - CONSTRUCTION NOT PASS THROUGH MAXIMUM RISE TO BE 1-3/4'. MINIMUM RUN TO BE 10'. • MINIMUM HEAD HEIGHT TO BE V-8'. • MINIMUM STAIR WIDTH TO BE 36'. PROVIDE CONTINUOUS HAND RAIL 34' TO 38' OFF TREAD NOSING AND MUST EXTEND BEYOND BOTTOM TREAD. • PROVIDE GUARD RAILS AT LANDINGS, OPEN SIDED WALKING SURFACE, STAIRS, RAMPS, PORCHES, OR BALCONIES • MIN. 36' HIGH W/ CLEAR SPACE PER 8312.1.1 AND 831212 HANDGRIP PORTION OF HANDRAIL SHALL BE NOT LESS 1 1/4' NOR MORE THAN 2' IN CROSS SECTIONAL DIM. • WINDING TREADS PER IRC R311.1BZ SPIRAL STAIRS PROVIDE MM 1 1/2' RUN e A POINT 12' FROM WHERE TREAD IS NARROWEST PER IRC 8311.110.1 i12 co `� HANDRAILS WILL BE RETUNED OR SHALL TERMINATE IN NEWEL POST OR SAFETY TERMINALS PER IRC 8311.1.8.2 HANDRAIL TO BE PRESENT ON ON AT LEAST ONE SIDE OF STAIR HANDGRIP PORTION OF HANDRAILS SHALL HAVE CIRCULAR CROSS SECTION OF 11/4' MIN. i 2' MAX. EDGES SHALL HAVE A MIN. RADIUS OF k,'. 4 C, ALL REQUIRED GUARDRAILS TO BE 36' MIN. IN HEIGHT. OPENINGS FOR REQUIRED GUARDS ON THE SIDES OF STAIR TREADS SHALL NOT ALLOW A SPI -ERE 4 INCHES (102mm) TO PASS THROUGH. PER 831213 N0811s I� MAX 6' SPHERE UNABLE TO PASS THROUGH OPENING BELOW STAIR INSTALL U2' GWB * CEILING, AND WALLS (3) 2X12 STRINGERS AL STAIR DETAIL AND NOTES LAI- OrL1C.t0 19- MIN. ARE THAN 50% OF REQUIRED 'ER PORTION OF VENTILATED THAN 3' BELOW THE RIDGE OR E BALANCE OF REQUIRED ) BY EAVE VENTING. ERWOVEN FELT 41NG 4.26 GA ?905.2.8.5 ES 4 GABLES 2x SCREENED EAVE VENT BLOCKS W/(4) 21/8' HOLES EACH - PROVIDE APPROVED INSULATION BAFFLE TO ENSURE 1' MIN. AIR SPACE. CAL EXTERIOR WALL: :6 TOP PLATES STUDS 0 16' O.C. BOTTOM PLATE 5WT'G (APA RATED 24/0) BARRIER :RIOR SIDING PER ELEV. INSULATION W/ CONT. OR BARRIER i6l SIDE) ' YP. BD STUD NOTCHING AND BORING AIRING OR EXTERIOR WALL fCH 25%, BORING 40%. % BORING IF DOUBLED 4 56 OR EQUAL SUCCESSIVE STUDS. N -BEARING MAXIMUM NOTCH P., BORING 60%. LES NO CLOSER THAN 5/8 H TO FACE OF STUD. TL INE (DATION DRAIN: IA. PERF. PIPE GRAVEL FILL o W/ FILTER FABRIC NO rZ t 0-4 Q) a FIRE 5LOCKMG • MID -SPAN AND z M M STUD WALLS ALONG AND M LINE CONT. HANDRAIL 34'-38' WITH STRMGE88 IF AREA UNDER ABOVE TREAD NOSING. / 2x4 THRUST BLOCK STAIRS IS UNFINISHED PICKETS PER IRC ON OPEN SIDE y dd y N Z" INTERIOR a � o N DECK 1' PT RISERS / JOISTS PER PLAN i DBL JST P.T. 2X12 TREADS HU212 TO SYRINGE MTL. HANGERS AT EA. STRINGER \ 3-2X12 P.T. STRINGERS 6'X IDI MIN. OIC PNAD -EXT RIO R \ HL 35 /// AL STAIR DETAIL AND NOTES LAI- OrL1C.t0 19- MIN. ARE THAN 50% OF REQUIRED 'ER PORTION OF VENTILATED THAN 3' BELOW THE RIDGE OR E BALANCE OF REQUIRED ) BY EAVE VENTING. ERWOVEN FELT 41NG 4.26 GA ?905.2.8.5 ES 4 GABLES 2x SCREENED EAVE VENT BLOCKS W/(4) 21/8' HOLES EACH - PROVIDE APPROVED INSULATION BAFFLE TO ENSURE 1' MIN. AIR SPACE. CAL EXTERIOR WALL: :6 TOP PLATES STUDS 0 16' O.C. BOTTOM PLATE 5WT'G (APA RATED 24/0) BARRIER :RIOR SIDING PER ELEV. INSULATION W/ CONT. OR BARRIER i6l SIDE) ' YP. BD STUD NOTCHING AND BORING AIRING OR EXTERIOR WALL fCH 25%, BORING 40%. % BORING IF DOUBLED 4 56 OR EQUAL SUCCESSIVE STUDS. N -BEARING MAXIMUM NOTCH P., BORING 60%. LES NO CLOSER THAN 5/8 H TO FACE OF STUD. TL INE (DATION DRAIN: IA. PERF. PIPE GRAVEL FILL o W/ FILTER FABRIC NO 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer, Plan No: LS2-2472-2R Date: 4-5-16 �7 rZ t 0-4 Q) a z M •e• y y dd y N Z" a � o N 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer, Plan No: LS2-2472-2R Date: 4-5-16 �7 UPPER FLOOiZ F.LEGTRIGAL MAIN FLOOiZ ELECTRICAL 1/411= I' -O II INTERIOR STAIRWAY ILLUMINATION PER SEC R303.1 IRC INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN 1 FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHEF;r= THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS PROVIDED. EXTERIOR STAIRWAY ILLUMINATION PER SEC R303.8 IRC EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. N11 ELECTRICAL KEY OVERHEAD CAN OUTLET DUPLEX OUTLET 220V OUTLET COMBO. EXT. FAN (VTOS) t LIGHT COMBO SMOKE ALARM - CARBON MONO. DET. DO 110 V W/ BATTERY BACKUP CABLE T.V. JACK PHONE UNDER COUNTER LIGHTS Y ~C GAS OUTLET T HOSE BIBS 4 EXT. FAN VTOS 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer, Plan No: LS2-2472-2R F_ Date: 4-5-18 LJ z °i Z Cd �;) rA ♦♦♦ E 00 ® H 000 �Go y eq C yN Z Q, z -® a �Q �1 N ♦ 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer, Plan No: LS2-2472-2R F_ Date: 4-5-18 LJ OIL ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION, WITH WASHINGTON STATE AMENDMENTS. DESIGN LOADS: ROOF LIVE LOAD DEAD LOAD FLOOR LIVE LOAD DEAD LOAD 25 PSF (SNOW) 15 PSF 40 PSF (RESIDENTIAL) 10 PSF WIND BASIC WIND SPEED 110 MPH (3 SECOND GUST, ULTIMATE LOAD) RISK CATAGORY II, EXPOSURE B, Kz, = 1.0 SEISMIC EQUIVALENT LATERAL FORCE PROCEDURE BEARING WALL SYSTEM (LIGHT -FRAMED WALLS) SITE CLASS: D SEISMIC DESIGN CATAGORY: D $s = 1.5 - IBC FIGURE 1613.3(1) SDs = 1.0, 1E = 1.0, R=6.5 Cs = 0.154 INSPECTIONS: NO SPECIAL INSPECTIONS ARE REQUIRED. NOTIFY THE BUILDING DEPARTMENT FOR INSPECTIONS REQUIRED BY LOCAL ORDINANCE. ALL PREPARED SOIL BEARING SURFACES SHALL BE INSPECTED BY A SOILS ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL. FOUNDATIONS: PLACE FOOTINGS ON NATIVE OR COMPACTED SOIL WITH 1,500 PSF BEARING CAPACITY (ASSUMED). BOTTOM OF EXTERIOR FOOTINGS SHALL BE MINIMUM 1'-6" BELOW OUTSIDE FINISHED GRADE. BACKFILL WALLS WITH A WELL DRAINING MATERIAL FREE OF ORGANIC OBJECTS OR DEBRIS. CONCRETE: THE SELECTION OF MATERIALS FOR AND THE MIXING AND PLACING OF ALL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, 2015 EDITION. MATERIALS SHALL BE PROPORTIONED TO PRODUCE A DENSE, WORKABLE MIX HAVING A MAXIMUM SLUMP OF 4 INCHES WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER USE MINIMUM PC = 3,000 PSI WITH 5.5 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A MAXIMUM OF 52 GALLONS OF WATER PER 94 LB SACK OF CEMENT. ALL CONCRETE SHALL CONTAIN AN AIR ENTRAINING AGENT. THE AMOUNT OF ENTRAINED AIR SHALL BE 41/2% ilB% BY VOLUME. MAXIMUM SIZE OF AGGREGATE IS 11/2". ALL CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR EXPANSION JOINTS UNLESS SHOWN OTHERWISE. CONCRETE PURVEYORS/SUPPLIERS DELIVERY OR BATCH TICKET TO BE ON JOB SITE FOR BUILDING INSPECTOR VERIFICATION. REINFORCING STEEL: ALL REINFORCING STEEL SHALL BE MINIMUM GRADE 60 (Fy = 60,000 PSI) DEFORMED BARS IN ACCORDANCE WITH ASTM SPECIFICATION A-615. LAP ALL SPLICES 32 BAR DIAMETERS OR 1'-6" MINIMUM UNLESS OTHERWISE SHOWN. PROVIDE ELBOW BARS (32 DIA.) TO LAP HORIZONTAL STEEL AT COMERS AND INTERSECTIONS IN FOOTINGS AND WALLS. REINFORCEMENT SHALL BE ACCURATELY PLACED AND ADEQUATELY SUPPORTED BY APPROVED CHAIRS, SPACERS, OR TIES AND SECURED IN PLACE DURING GROUT OR CONCRETE PLACEMENT. MINIMUM CONCRETE COVER FOR REINFORCING STEEL: USE SLAB AND WALL BARS: INTERIOR FACES EXPOSED TO WEATHER OR EARTH FOOTING BARS PROTECTION 11/2 1'/2" (05 AND SMALLER) 2" (*6 AND LARGER) 3.. TIMBER: ALL LUMBER SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: BEAMS DF*2 OR BETTER POSTS DF*2 OR BETTER 2x FRAMING HF*2 OR BETTER ALL 2x TIMBER SHALL BE KILN DRIED. ALL GRADES SHALL CONFORM TO "WWPA GRADING RULES FOR WESTERN LUMBER", LATEST EDITION. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. RE -TREAT ALL CUT ENDS, NOTCHES, AND DRILLED HOLES IN ACCORDANCE WITH AWPA M4. MAINTAIN MINIMUM b" CLEAR BETWEEN WOOD AND EXPOSED EARTH. MAINTAIN 8" CLEAR BETWEEN EXPOSED EARTH AND NON -TREATED WOOD AT EXTERIOR FOUNDATION WALLS. ALL NAILS SHALL BE GALVANIZED BOX OR COMMON NAILS. FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL IN ACCORDANCE WITH SECTION IBC 2304.10.5. ALL MINIMUM NAILING SHALL BE PER IBC TABLE 2304.10.1 UN.O. MACHINE BOLTS TO BE A-301. BOLT HEADS AND NUTS BEARING AGAINST WOOD SHALL BE PROVIDED WITH STANDARD CUT WASHERS. MISCELLANEOUS HANGERS TO BE 'SIMPSON' OR ICC APPROVED EQUAL. ALL HANGERS TO BE FASTENED TO WOOD WITH PROPER NAILS AND ALL HOLES SHALL BE NAILED. GLUED LAMINATED WOOD MEMBERS: GLUED LAMINATED WOOD BEAMS (GLB) TO BE IN ACCORDANCE WITH ANSI/AITC STANDARD A190.1, AMERICAN NATIONAL STANDARD FOR STRUCTURAL GLUED LAMINATED TIMBER USE STRESS GRADE COMBINATION 24F -V4 (Fb = 2,400 PSI) FOR SIMPLE SPANS AND 24F -V8 FOR CANTILEVER AND CONTINUOUS SPANS. SIMPLE SPANS SHALL BE CAMBERED ON A 3500' RADIUS U.N.O. GLUE SHALL BE CASEIN WITH MOLD INHIBITOR UNLESS OTHERWISE SPECIFIED, SEALER SHALL BE APPLIED TO ENDS OF ALL MEMBERS. BOTTOM LAMINATION TO BE FREE OF UNSOUND KNOTS LARGER THAN 1/2" DIAMETER AITC STAMP AND CERTIFICATION REQUIRED. PREFABRICATED JOISTS: JOISTS SHALL BE AS NOTED ON THE PLANS AND AS MANUFACTURED BY TRUSS JOIST WEYERHAEUSER OR APPROVED EQUIVALENT. JOISTS TO BE ERECTED IN ACCORDANCE WITH THE PLANS AND THE MANUFACTURER'S DRAWINGS AND INSTALLATION INSTRUCTIONS. CONSTRUCTION LOADS BEYOND THE DESIGN LOADS ARE NOT PERMITTED. PROVIDE ERECTION BRACING UNTIL SHEATHING MATERIAL HAS BEEN INSTALLED. PROVIDE SOLID BLOCKING AT CONCENTRATED LOADS FROM ABOVE AND WEB STIFFENERS PER MANUFACTURER'S DIRECTIONS. JOIST HANGERS TO BE SIZED AND PROVIDED BY THE MANUFACTURER OR SUPPLIER PARALLEL STRAND LUMBER (PSL): PARALLEL STRAND LUMBER (PSL) TO BE BY TRUSS JOIST WEYERHAEUSER (PARALLAM) OR APPROVED EQUIVALENT (Fb = 2,900 PSI, E = 2.0 x 10(o PSI). MATERIAL SHALL BE DESIGNED 4 MANUFACTURED TO THE STANDARDS SET FORTH IN E5R-1381. BEARING LENGTH SHALL NOT BE LESS THAN 13/4". DO NOT CUT OR NOTCH BEAMS WITHOUT PRIOR APPROVAL OR ENGINEER HEEL CUTS SHALL NOT OVERHANG INSIDE FACE OF SUPPORTING MEMBER BEARING WALL FRAMING: ALL DOOR AND WINDOW HEADERS NOT CALLED OUT OR OTHERWISE NOTED ON THE PLANS SHALL BE 4x8 DF2 WITH ONE CRIPPLE AND ONE STUD EACH END FOR OPENINGS 5'-0" OR LESS AND TWO CRIPPLES AND ONE STUD FOR OPENINGS MORE THAN 5'-0" WIDE. ALL COLUMNS NOT CALLED OUT ON THE PLANS SHALL BE TWO (2) STUDS. SPIKE LAMINATED COLUMNS TOGETHER WITH 16d 6 12" O.C. STAGGERED. STAGGER SPLICES AT TOP PLATES MINIMUM 48" AND NAIL WITH 16d tv 8" O.C. SHEAR WALLS: ALL SHEAR WALL SHEATHING NAILING AND ANCHORS SHALL BE AS DETAILED ON THE DRAWINGS AND NOTED IN THE SHEAR WALL SCHEDULE. USE APA RATED SHEATHING (24/1(o) WITH A MINIMUM PANEL EDGE NAILING OF ed a b" O.C. UNLESS NOTED OTHERWISE. ALL SHEAR WALL NAILING SHALL BE COMMON WIRE OR GALVANIZED BOX NAILS. FASTENERS IN PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL. BLOCK ALL UNSUPPORTED PANEL EDGES. DESIGNATED 3x FRAMING MAY BE (2) 2x MEMBERS FACE -NAILED WITH 16d m 12" O.C. STAGGERED. ALL HEADERS SHALL HAVE STRAP CONNECTORS TO THE TOP PLATE AT EACH END WHEN THE HEADER INTERRUPTS THE TOP PLATE. USE 'SIMPSON' LSTA24 CONNECTOR UN.O. FLOOR AND ROOF FRAMING: DIMENSIONAL FRAMING MEMBERS SHALL BE FREE OF SPLITS, CHECKS, AND SHAKES. PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE LENGTH AND ALL AROUND ALL OPENINGS IN FLOORS AND ROOFS UN.O. PROVIDE SOLID BLOCKING AT RIM JOISTS BELOW CONCENTRATED LOADS FROM ABOVE. APPLY 3/4" RATED SHEATHING (40/20) GLUED AND NAILED TO FLOOR FRAMING MEMBERS WITH 8d COMMON OR GALVANIZED BOX NAILS AT 6" O.C. AT ALL SUPPORTED EDGES AND ed COMMON OR GALVANIZED BOX NAILS AT 12" O.G. AT INTERIOR SUPPORTS. APPLY 1/2" RATED SHEATHING (24/1(o) ON ROOF NAILED TO STIFFENERS OR RAFTERS WITH 8d COMMON OR GALVANIZED BOX NAILS AT 6" O.C. AT SUPPORTED EDGES AND ed COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT INTERIOR SUPPORTS. LAY SHEATHING PERPENDICULAR TO FRAMING AND STAGGER PANEL EDGES. FLOOR AND ROOF TRUSSES: TRUSSES TO BE DESIGNED AND SUPPLIED IN ACCORDANCE WITH ANSI/TPI 1-2014. THE TRUSS CALCULATION PACKAGE SHALL BE PREPARED UNDER THE DIRECT SUPERVISION OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. THE TRUSS ENGINEER SHALL ASSUME ALL RESPONSIBILITY FOR THE WORK OF ALL SUBORDINATES INVOLVED IN THE PREPARATION OF THE TRUSS PLACEMENT PLAN AND TRUSS DESIGN DRAWINGS. EACH TRUSS SHALL BE PLANT FABRICATED AND SHALL BEAR THE QUALITY CONTROL STAMP, MANUFACTURER'S NAME, DESIGN LOAD, AND MAXIMUM SPACING. ALL MECHANICAL CONNECTORS SHALL BE ICC APPROVED AND LOADS SHALL BE IN ACCORDANCE WITH THE RECOMMENDED ALLOWABLE LOADS. MANUFACTURER SHALL PROVIDE ALL TRUSS -TO -TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. FABRICATOR SHALL SUBMIT SHOP DRAWINGS TO THE BUILDING DEPARTMENT FOR APPROVAL PRIOR TO INSTALLATION AND VERIFY ALL TRUSS LENGTHS PRIOR TO FABRICATION. TRUSSES SHALL BE BRACED TO PREVENT ROTATION AND PROVIDE LATERAL STABILITY IN ACCORDANCE WITH THE CONSTRUCTION DRAWINGS AND INDIVIDUAL TRUSS DRAWINGS. GENERAL CONSTRUCTION NOTES: ALL CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND METHODS, TECHNIQUES, AND SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE SPECIFIED WORK THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ALL CONDITIONS AT THE JOB SITE INCLUDING BUILDING AND SITE CONDITIONS BEFORE COMMENCING WORK AND BE RESPONSIBLE FOR SAME. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING DEPARTMENT FOR ALL BUILDING DEPARTMENT REQUIRED INSPECTIONS. DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. THE DETAILS SHOWN ARE TYPICAL AND SHALL BE USED FOR LIKE OR SIMILAR CONDITIONS NOT SHOWN. VARIATIONS AND MODIFICATIONS TO WORK SHOWN ON THE DRAWINGS SHALL NOT BE CARRIED OUT WITHOUT THE WRITTEN PERMISSION FROM THE ARCHITECT OR ENGINEER SHEAR LULL SCNEDULE MARK MINIMUM SHEATHING (1) SHEATHING NAILING (U ANCHOR BOLTS (3) REMARKS (4, 5) '/2" CDX Sd a 6" O.C. 5/8" 6 60" O.C. Qa11 = 230 PLF OR OSB 1/2 11 CDX Sd a 4" O.C. Nall tv 3211 O.C. Qa I I = 350 PLF OR OSB '/2" CDX 8d a 3" O.C. 5/8" 6 1(0" O.C. QaII = 450 PLF C OR OSB USE 3x STUDS AT ABUTTING PANEL EDGES 4 STAGGER NAILS R SEE DETAIL 12 / 52.0 FOR CONSTRUCTION NOTES 1) ALL WALLS DESIGNATED" D" ARE SHEAR WALLS. EXTERIOR WALLS SHALL BE SHEATHED WITH RATED SHEATHING (24/0) AND NAILED AT ALL PANEL EDGES (BLOCKED) PER SCHEDULE. NAILING AT T1-11 PANELS SHALL BE THROUGH EACH EDGE OF EACH PANEL. NAILING AT INTERMEDIATE FRAMING TO BE AT 12" O.C. NAILING NOT CALLED OUT SHALL BE PER IBC TABLE 2304.10.1. NAILING IN PRESERVATIVE TREATED LUMBER SHALL BE STAINLESS STEEL OR OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL PER ASTM AI53. 2) HOLDOWNS AND OTHER FRAMING HARDWARE BY 5IMP50N STRONG TIE OR ICC APPROVED EQUAL TO BE USED PER PLAN. ENDS OF SHEAR WALLS SHALL USE DOUBLE STUDS MINIMUM. 3) USE MINIMUM OF TWO (2) BOLTS PER SILL PIECE WITH ONE BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 5" FROM EACH END OF EACH PIECE. EMBED BOLTS MINIMUM OF 1" INTO CONCRETE. WASHERS TO BE 3" x 3" x 1/4" PER IBC SECTION 230832 AND OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL IN ACCORDANCE WITH ASTM AI53. 4) ALLOWABLE LOADS ARE PERMITTED TO BE INCREASED 40% FOR WIND DESIGN IN ACCORDANCE WITH IBC SECTION 23063. 5) DESIGNATED 3x STUDS MAY BE (2) 2x MEMBERS FACE -NAILED WITH 1(od a 12" O.C. STAGGERED. LSTA36 - HDR 4 SILL, TO 3x BLOCKING. MP. 2 PLACES) LSTA36 - HDR 4 SILL TO 3x BLOCKING: MR 2 PLACES) LSTA36 -HDR 4 SILL TO 3x BLOCKING: (TYP. 2 PLACES) LSTA_% - HDR 4 SILL v STEM WALL a 4 4 a ° V2 all ° ° _� ° I MAX. CONTINUOUS FTG._/ MINIMUM REINFORCEMENt I STEPPED FOOTING DETAIL SI0 SCALE: 34' : P-0" MSTC40 HOLDOWK ALIGN WITH EMBEDDED STHD TYPE HOLDOWN BELOW. SHEATHING 4 NAILING PER PLAN. SPLICE TO OCCUR ON COMMMON MEMBER OR BLOCKING SHEATHING 4 NAILING PER PLAN. MATCH WALL ABOVE URO. FINISH GRADE rA 16d a 16" O.C. SOLE PLATE NAILING. 3/4" SUBFLOOR /—(3) 8d JOIST -TO -TOP PLATE URO. MAINTAIN 4-4 MIN. I1/2" END DISTANCE. 2 x 6 STUD a 16" O.C. USE -DBL STUD 9 ENDS OF SHEAR WALLS 4 HOLDOWNS. 2x NAILER AND PT SILL w/ s/s"OMS" _ ANCHOR BOLT 4 3" x 3" x 1/4" WASHER AT V-0" O.G. UNA. (ALT. MASA a 48" O.C.) _ STHD TYPE HOLDOWN PER PLAN. 04 BAR 0 10" O.C. - HORIZ —04LBAR a 16" OC. - VERT. M FINISH GRADE 04 BAR CONTINUOUS MINIMUM (TYP OF 2) o v �D 0 D P 8" z CRIPPLE WALL WITIH BACKFILL FOUNDATION SIO SCALE: 340 - P-0" GOPi'�I��-I� 201, �E�4 EN�INEE�� W U� I m cc 0 CIO b a cq w cq w m 0 co 0 cq cq I/2" RATED SHEATHING ad Is 6" O.C. (4" O.C. � SIM.) EXTERIOR SHEATHING PER 1/2" RACED SHEATHING w/ NOTE: � PLAN OR SCHEDULE TRUSS t0 DEVELOP = ad a 4 O.C. t0 FRAMING CAPACfTY OF CONNECTOR. W RATED SHEATHING Hl FRAMING ANCHOR Sd 4" O.C. �- TRUSS PER PLAN �\ I � w EACH TRUSS. USE H10A-2 2x BLOCKING w/ 16d S" O.C. 2x BLOCKING w/ (2) Sd ad Is 6" O.C. AT DBL TRUSS. GABLE END TRUSS. 1 t0 STUD EACH END DBL 2x TOP PLATE. —1 Lit W RATED SHEATHING (BEAM At SIM.) U N N A35 9 48" O.C. RAFTER OR TRUSS PER PLAN (USE 24" O.C. At SIM.) w/ (2) ad t0 2x BLOCKING 2x VENTED BLOCKING. TRUSS PER PLAN DBL 2x COP PLATE. LAP 2x BRACE PER TRUSS SUPPLIER CONNECTOR SCRAP SPLICE 4'-0" MIN. 4 NAIL w/ DBL 2x COP PLATE. LAP 16 6 OR � 48" O.C. SECURE w/ d G O.C. STAGGERED. 2x STUD PER PLAN PER PLAN. END NAIL t0 TRUSS � EACH END w/ (2) ad. SPLICE 4'-0" MIN. 6 NAIL A34 EACH END. NOTE: NOTE: INSTALL CONNECTOR PRIOR SHEATHING AND NAILING PER w/ 16d 6" O.G. STAGGERED SHEATHING S NAILING 1 SEE ARCH FOR FLASHING PLAN OR SCHEDULE. SPLICE PER PLAN OR SHEAR 2x FRAMING PER PLAN. REQUIREMENTS. 2x STUD (NOT SIM) t0 PLACING COMMON TRUSSES 2x FRAMING PER PLAN. TO OCCUR ON COMMON (BEAM At SIM) WALL SCHEDULE. (HEADER tv SIM.) a� o MEMBER OR BLOCKING ~ .01 '�0 0 � w w a en 1 T1'PICAL ROOF FRAMING CONNECTION 2 ROOF FRAMING G,45LE END 3 LOWER ROOF FRAMING e SHEAR WALL 4 DRAG STRUT CONNECTION 52 0 SCALE: I" = I'-0" 52 0 SCALE: I" = I'-0" 52.0 SCALE: I" = 1'-0" 52 0 SCALE: 1" = I'-0" b o ,ti U q 0 NOTE: pBL 2x COP PLATE 0 o SHEATHING 4 NAILING PER SEE ARCH FOR FLASHING SOLE PLATE NAILING. 16d S" O.C. SOLE a" ~ PLAN OR SCHEDULE. REQUIREMENTS. USE 16d 6 16" O.C. MIN. MSTC HOEDOWN PLATE NAILING. _________________ ad 4" O.C. SCRAP PER PLAN SOLID RIM JOIST NDR PER PLAN. - ,~0 co �co RIM JOIST w/ (3) ------------------- as -- Sd 10 4" O.G. ! �" o 16d EACH JOIST i I tO (3) ad JOIST -TO -COP ROOF SHEATHING PLATE UN.O. MAINTAIN 3/4" SUBFLOOR ! i----- — — �– — PER PLAN 2x BLOCKING MSTC HOLDOWNMIN. 11/2 END DISTANCE.SH SHEATHING NAILING PER PLAN. STRAP PER PLAN ------ —3x BLOCKING. EXTEND SPLICE t0 OCCUR ON COMMMON a b cq MEMBER OR BLOCKING SHEATHING 4 NAILING1 1'_0 l2) BAYS (24" MINIMUM) PER PLAN ! OR t0 CORNER cq �J 2x STUD (TYP) U3 3/4" SUBFLOOR TRIMMER STUDS) w W w 00- cq TRUSS OR RAFTER 2x FRAMING PER PLAN. J016T PER PLAN (USE pBLcq PER PLAN(BEAM At SIM.) JOIST PER PLAN w/ HU5C210-2 HOEDOWN) KING STUD 2x pBL TOP PLATE. LAP 2x BLOCKING w/ A35 SPLICE 4'-0" MIN4 NAIL –\ FRAMING ANCHOR t0 . 2x NAILER OR TRUSS TOP PLATE. W/ 16d a 8" O.C. w/ 16d 6 6" O.C. STAGGERED. 2x FRAMING PER PLAN./2 RATED SHEATHING 4 NAILING PER SCHEDULE. LSCA STRAP PER 5 ROOF FRAMING 5HEAR WALL TYPICAL FLOOR FRAMING CONNECTION FLOOR FRAMING CANT. J015T PLAN (TYP). S2 0 SCALE: I" = I'-0" S2 0 SCALE: I" = 1'-0" S2 0 SCALE: I" = 1'-0" 2x SILL PLATE i � II . --- ad 4" O.C. II 3/4" SUBFLOOR 3x BLOCKING 2x JOIST PER PLAN 1PLACE NAILING. 6d S" O.C. SOLE (TYP) 16d 's 4" O.C. SOLE 2x BLOCKING w/ A35 SHEATHING NAILING PER PLATE NAILING. FRAMING ANCHOR AT SHEATHING NAILING 8 5HE,4R WALL FORCE TRANSFER DETAIL PLAN OR SCHEDULE. 6" O.C. TO TOP PLATE. 2x BLOCKING PER PLAN OR ad 6" O.C. LINOS2 0 SCALE: I" = 1'-0" SCHEDULE 3/4 " SUBFLOOR I SI,IBFLOOR LSTA24 STRAP (FAR SIDE) 11 1(o j SHEATHING i NAILING PER MINIMUM 2x COP PLATE ]zNAIL SHEATHING t0 HDR JOIST AN. PLAN OR SCHEDULE. JOIST PER PLAN HDR PER PLAN. EXTEND w/ ad 3" O.C. EACH WAY. �" PER PL DBL OVER PANEL t0 KING STUD. 1� AT MSTC HOLDOWN - . 2x FRAMING PER PLAN. ' ' ' ; ; 1. FASTEN COP PLACE t0 HEADER �� MSTC HOEDOWN PER (BEAM At SIM.) :: PLAN BEYOND. BEAM PER PLAN w/ (2) ROWS 16d AT 3" O.C. LLI (2) 2x SCUDS (TYP.) al _ILII e FRAMING ,AT INTERIOR 5HEAR WALL 10 FRAMING AT INTERIOR SHEAR WALL 11 5HEAR WALL FRAMING AT FLUSH SEAM —A -A s2 0 SCALE: I _ I 0 s2.0 SCALE: I _ 1 0 .: 4x BLOCKING 9 MIDDLE 52 0 SCALE: I" = I'-0" " - " " " 24" IF REQUIRED./ ad 6" O.C. 2x BLOCKING w/ (3) ad 16d 16" O.C. SOLE 10'-0" — TOE -NAIL t0 4x BEAM 4 2x STUD PER PLAN. USE MINIMUM 2x STUD PER PLAN. USE DBL MAXIMUM * �1 +'+ + III PLATE NAILING. I'; l2) ad t0 JOISTS. (2) 2x STUD 6 ENDS OF SHEAR SHEATHING 4 NAILING PER STUD AT END OF SHEAR WALLS ;'i +' /2 RACED SHEATHING 124/0 EXP U. SUBFLOOR PER PLAN 3/4" SHEATHING � +! WALLS 4 HOLDOWNS. SEE SHEAR PLAN OR SCHEDULE HOEDOWNS. SEE SHEAR WALL I' ;:! NAIL L (2) ROWS ad � 3 O.C. At JOIST PER PLAN WALL SCHEDULE FOR 3x STUDS. ANCHOR BOLT w/ 3"x3"x1/4" SCHEDULE FOR 3x STUDS. PANEL EDGES. SHEATHING NAILING PER WASHER SEE SCHEDULE FOR 2x Pt SILL w/ ANCHOR BOLI S AN FOR t0 OF !' yli SIZE 4 SPACING -USE Ne"O AT 4 3" x 3" x 1/4 WASHER PER EE PL R P ..i I.; PLAN. SPLICE t0 OCCUR CONCRETE At 61MILAR !+ ��� (2) 2x PLATE. (NAIL ON COMMON MEMBER 1;(00" O.C. UN.O. PLAN OR SCHEDULE. !• AC POST CAP 2x Pt SILL USE Ns"o a 60" O.C. MIN. .j. �;� SNt'G TO EA PLACE) OR BLOCKING. 4 SLAB ON GRADE OVER TOP OF STEM WALL __ '+ ` 04 AR - HORIZ. MIN. 6 MIL VAPOR BARRIER ELEV. VARIES �* ; ,'��p 4x4 PT POST 6" MIN. (INOT tv S.O:G.) !1 6" MfN_ �' e �� (4x6 AT SPLICE) FINISH GRADE 12 MAX, 5THD HOLDOWN PER PLAN. FINISH GRADE OR tH 14 H 2x Pt SILL ' (S.O.G. SIM.) I SLAB ON GRADE ! S D HOLDOWN UNO. 5 MAB ANCHOR 18�I #41 BAR s 24" O.C. - VERT. (2) /8 � ANCHOR BOLT w/ MIN. (ALT. A34 ANCHOR MIN. STHD HOLDOWN-_,,---_______ OLDOWN ° 4 BAR - HORIZ. \_7 EMBEDMENT 4 3" x 3" x I/4" TWO SIDES) 1211 I'-6" MIN GALVANIZED lE WASHER PER P 1'-6" MIN. a #4!BAR 24" O.C. - VERTICAL FOUNDATION PER PLAN. FTG PER PLAN –\ ° ° MIN. 2'-6" MAX. � D �, � ° 04 BAR CONTINUOUS � MIN. S" THICK STEM WALL w/ $�� '� $ #4 BAR HORIZ. TOP 4 BOTTOM. FINISH GRADE o D 12 PORTAL FRAME PANEL $$, #4 BAR CONT. S2 0 SCALE: NONE Z)I'-4" \ 2 13 FLOOR FRAMING ,AT CRAWL 5PACE FOUNDATION ,AT CRAWL 5PACE 15 FOUNDATION ,AT 5LA5 ON GRADE 52.0 SCALE: I" = I'-0" 520 SCALE: I" = I'-0"52.0 SCALE: NONE GOPi'Rfr=314T 201x, 5EGA ENGINEERS JOB 10-101