Loading...
0343 Final Construction Punch List 100406 City of Yelm Community Development Department 105 Yelm Avenue West P.O. Box 479 Yelm, WA 98597   October 4, 2006 John Lubbesmeyer Pinedale Construction 1151 East 112th Street Tacoma, Washington 98445 RE: Final Construction Punch List Vista Green City of Yelm Project No. SUB-05-0343-YL Dear Mr. Lubbesmeyer: Our department has completed a final walk thru on the above mentioned project. The following are a few minor items that were discovered during this walk thru, these items must be completed to assure in finalizing the project. These items are listed as follows: Civil Engineering Department Comments: October 2, 2006 Sidewalk not complete on Longmire & Durant. Lots throughout project need to be graded and brought to sidewalk elevation with Top Soil. Debris needs to be removed at all sites. Storm Pond, Needs to be completed. Broken Sidewalk Panel at the end of Durant needs to be replaced. Sidewalk on 100th Avenue Needs to Tie-In to Existing Sidewalk. Cable or Telcom cable needs to be buried or placed in boxes. Community Development Department – Landscaping Hydroseeding needs to be completed within Plat and within Storm Pond where top soil is visible. 4” x 6” pressure treated wood and root barriers around street trees required. Trees missing on Lots 10 and 14. Water Department Comments – September 29, 2006 1. The Water Department needs a copy of the well abandonment report. 2. The meter setters need to be straightened out and operating nut spread apart so the meters can be set in at the following lots 1, 2, 3, 4, 5, 6, 12, 15, 17, 18 and 19. 3. The fire hydrant at 100th Ave. and Durant Dr. is too high. See the fire hydrant detail on Your prints. 4. We have the bacterial test and backflow test results. Sewer Department Comments – October 3, 2006 Gate valve at Sta. 13+33.43 needs lid with “sewer” written on it. Gate valve at Sta. 2+47.54 has no toning wire . The End of Line clean out cap at Sta. 10+00 must be brought up as high as possible in the valve vault. Expose all ball valves and toning wire in the Carson Boxes (some contractors use 4” or 6” stand pipes to provide access to valves within the carson boxes) The Carson box at lot 12 must be brought up to grade. Public Works Department Comments – September 27, 2006 Durant Drive missing sidewalk panels. One bad panel at the end of Durant Drive. Approximately 54’ of sidewalk missing on 100th Ave. 1 panel with hand prints on it. No back grading.  Please revise and repair the above comments and concerns. When you have completed these items, you may contact me, to arrange for a second walk through. If you have any questions or comments, please call me at (360) 458-8423 and I will be happy to further assist you. Respectfully City of Yelm Community Development Steve Harrington Civil Engineering Inspector steveh@ci.yelm.wa.us