PL 040506 Red Wine Expansion
City of Yelm
Community Development Department
105 Yelm Avenue West
P.O. Box 479
Yelm, WA 98597
Pre-Application Meeting
April 5, 2006
These comments are preliminary in nature and are not intended to represent final comments and or requirements for the City of Yelm. Until a complete application is made, the Community
Development Department can only attempt to inform the applicant of general requirements as they appear in the form presented by the applicant at the time of pre-submission.
Proponent: Lynne Glore7906 Kelly Beach RoadOlympia, WA 98513
Project Proposal: Expand existing restaurant with outdoor seating area
Project Location: 704 Yelm Avenue West
Zoning and Setbacks
The property is zoned Commercial (C-1), which allows restaurants as a permitted use. The existing restaurant is a pre-existing, non-conforming use pursuant to Chapter 17.93 YMC and
may be continued and maintained provided that any expansion would require a site plan review approval and the site to be brought into compliance with all City standards.
Minimum Lot Size – 5,000 square feet
Side property line – 10 feet
Rear property line – 20 feet
Front property line – 15 feet
Maximum height – 40 feet
Parking
Section 17.72 YMC establishes requirements for off-street parking and loading facilities and their design shall be regarded as the minimum; however, the owner, developer or operator
of the premises for which the parking facilities are intended shall be responsible for providing adequate amounts and arrangement of space for the particular premises even though such
space or its arrangement is in excess of the minimum set forth in the chapter.
Establishments for the sale and consumption of food and beverages require one (1) parking space for every 200 square feet of gross floor area. The previous land use approval for the
construction of the espresso stand on the property indicated that, at
that time, 8 parking spaces were required for both uses. The addition of outdoor seating would not add any gross floor area and, therefore, would not require additional parking, provided
that internal spaces within the building remain. A loading area will be required to be identified for the restaurant, however.
All driveway approaches, fire access lanes, and loading lanes must be paved and meet minimum dimensional requirements of the Development Guidelines, which range from 20 feet in width
for a fire lane to 23 feet for a parking lot access drive.
Landscaping
Type II landscaping is intended to provide visual separation of uses from streets, and visual separation of compatible uses so as to soften the appearance of parking areas, and building
elevation. A typical type II landscaping buffer is a landscape strip 8 feet in width with a mix of trees and shrubs. This landscaping is required along all sides of the property.
Type III landscaping is intended to provide visual relief where clear sight is desired. This landscaping type is utilized along pedestrian corridors and walks for separation of pedestrians
from Street and parking areas. Typically, this includes a 6 foot landscaping strip with street trees every 35 feet on-center and grass or sod. This landscaping buffer will be required
along Cullens Road and Yelm Avenue, although the Yelm Avenue frontage will be completed through the Killion Road LID, if approved by the City Council.
Type IV landscaping is intended to provide visual relief and shade in parking areas.
A conceptual landscaping plan is required with application for Site Plan Review. A final landscaping and irrigation plan is required prior to building permit issuance.
Refuse area must be large enough to accommodate a dumpster and recycle bin. Refuse areas must be of a material and design compatible with the overall architectural theme. If fencing
is used to enclose the refuse area, it must be landscaped with sight obscuring vegetation. No refuse container shall be permitted between a street and the front of a building. The
refuse area will be required to be upgraded through the site plan review process.
Traffic
The City has adopted a Transportation Facility Charge (TFC) of $750.00 per pm peak trip. The Ordinance provides a default table that the applicant can use to determine new pm trips
generated. For a restaurant, the trip generation rate is 6.13 per 1,000 square feet. When and if the addition is constructed, the TFC will be based on the square footage of the new
outdoor seating area.
Design Guidelines
The City has adopted design guidelines, which establish requirements for the architecture of new buildings, screen for parking lots, and similar aesthetic requirements. Because the
building is existing and there is no change of use proposed, only the outdoor seating area will be reviewed for consistency with the Design Guidelines for the City and there only issue
will be screening the seating area from the street frontages to soften its appearance.
SEPA
An environmental checklist is not required as the project does not include a structure over 4,000 square feet or parking for more than 20 vehicles.
Site Plan Review
Chapter 17.84 YMC establishes the Site Plan Review process for new and expanded land uses within Yelm. Site Plan Review is an administrative process which is heard by the Site Plan
Review Committee, comprised of staff from the Community Development Department. The minimum application requirements are located in Section 17.84.060 YMC and are listed on the application
form, attached. A project of this size can expect completed review in approximately 10 to 12 weeks. Land use approval typically contains conditions of approval that the applicant must
complete prior to receiving a building permit.
Upon satisfactory completion of all conditions of land use approval, the applicant can submit building plans for approval.