Loading...
Trump Energy FormsPrescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative _________________________________________________ Date ___________________________ 1. Small Dwelling Unit: 1.5 credits 2. Medium Dwelling Unit: 3.5 credits 3. Large Dwelling Unit: 4.5 credits 4. Additions less than 500 square feet: .5 credits Option Credit(s) 1a Efficient Building Envelope 1a 0.5 1b Efficient Building Envelope 1b 1.0 1c Efficient Building Envelope 1c 2.0 1d Efficient Building Envelope 1d 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 1.5 5d Efficient Water Heating 5d 0.5 6 Renewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 3.50 Slabd R-Value & Depth 49j 21 int 21/21h 30g 10, 2 ft Ceilingk Wood Frame Wallg,m,n Mass Wall R-Valuei Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Dwelling units exceeding 5000 square feet of conditioned floor area. Description Table R406.2 Summary Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. 3113-A C & E Development All Climate Zones 0.029 0.042 n/a 10/15/21 int + TB n/a n/a n/a 0.056 0.30 0.50 n/a 0.026 0.056 Floor Below Grade Wallc,m Glazed Fenestration SHGCb,e Fenestration U-Factorb Skylight U-Factor U-FactoraR-Valuea Window, Skylight and Door Schedule Project Information Contact Information Width Height Ref.U-factor Qt.Feet Inch Feet Inch Area UA Exempt Swinging Door (24 sq. ft. max.)0.30 1 3 0 6 8 20.0 6.00 0.0 0.00 Vertical Fenestration (Windows and doors) Component Width Height Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA 0.30 3 6 0 5 0 90.0 27.00 0.30 2 1 3 5 0 12.5 3.75 0.30 2 2 6 5 0 25.0 7.50 0.30 1 4 0 3 6 14.0 4.20 0.30 1 2 0 4 0 8.0 2.40 0.30 1 6 0 6 8 40.0 12.00 0.30 2 4 0 4 0 32.0 9.60 0.30 2 2 6 4 6 22.5 6.75 0.30 2 1 6 1 6 4.5 1.35 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Vertical Fenestration Area and UA 248.5 74.55 Vertical Fenestration Area Weighted U = UA/Area 0.30 Overhead Glazing (Skylights) Component Width Height Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.000.0 0.00 0.0 0.00 Sum of Overhead Glazing Area and UA 0.0 0.00 Overhead Glazing Area Weighted U = UA/Area 0.00 268.5 80.55Total Sum of Fenestration Area and UA (for heating system sizing calculations) 3113-A C & E Development 6050 1350 2650 4036 2040 6068 Sliding Door 4040 2646 1616 Exempt Glazed Fenestration (15 sq. ft. max.) (07/01/13) Simple Heating System Size: Washington State Project Information Contact Information Heating System Type: To see detailed instructions for each section, place your cursor on the word "Instructions". Design Temperature Instructions Design Temperature Difference (∆T)55 ∆T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft)1,791 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft)9.0 16,119 Glazing and Doors U-Factor X Area =UA Instructions 0.30 269 80.55 Skylights U-Factor X Area =UA Instructions 0.50 0 --- Insulation Attic U-Factor X Area =UA Instructions 0.026 1,085 28.21 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No selection 0 --- Above Grade Walls (see Figure 1)U-Factor X Area UA Instructions 0.056 2,007 112.39 Floors U-Factor X Area UA Instructions 0.029 1,035 30.02 Below Grade Walls (see Figure 1)U-Factor X Area UA Instructions ---0 --- Slab Below Grade (see Figure 1)F-Factor X Length UA Instructions ---0 ________ Slab on Grade (see Figure 1)F-Factor X Length UA Instructions ---0 ________ Location of Ducts Instructions Duct Leakage Coefficient 1.10 Sum of UA 251.17 Envelope Heat Load 13,814 Btu / Hour Sum of UA X ∆T Air Leakage Heat Load 9,575 Btu / Hour Volume X 0.6 X ∆T X .018 Building Design Heat Load 23,389 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 25,728 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 36,019 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. 3113-A C & E Development Above Grade Below Grade Figure 1. All Other Systems Heat Pump Rainier, Longmire Unconditioned Space No Slab on Grade in this project. No Slab Below Grade in this project. No Below Grade Walls in this project. R-30 R-21 Intermediate Select R-Value R-49