Loading...
20190047 CALCULATIONS DESIGN PACKAGE BUILDER: NPR HOLDINGS CUSTOMER: OB MUFREJ JOB NUMBER: 16-B-78515 TABLE OF CONTENTS Page Design Criteria 1 Notes on Drawings 2,3 Deflection Criteria 4 Building B 5-17 Original Design Completed thru Change Order # 0 Revision History Rev # Update Reactions? Reason for Revision Pages Revised Date Revised Eng. Project Engineer: Doug McAffrey (Oklahoma City) Checking Engineer: Allen Hurtz Signing Engineer: Allen Hurtz, P.E. 16-B-78515 8600 South I-35 Service Road  Oklahoma City, OK 73149  405.636.2010  starbuildings.com November 08, 2018 NPR HOLDINGS 3655 E MARGINAL WAY S SEATTLE, WA 98134-1150 16-B-78515 OB MUFREJ YELM, WA 40'0" x 80'0" x 18'0" To Whom It May Concern: This is to certify that materials for the subject structure have been designed in accordance with the order documents, specifically as shown per the attached Engineering Design Criteria Sheet. Aspects of code compliance as related to use or occupancy, such as sprinkler requirements, are not addressed by these documents. These materials, when properly erected on an adequate foundation in accordance with the erection drawings as supplied and using the components as furnished, will meet the attached loading requirements. This certification does not cover field modifications or the design of materials not furnished by Star Building Systems. The attached design criteria and calculations are to remain with and form part of this Letter of Certification. The calculations and the metal building they represent are the product of Star Building Systems or a division of its affiliate NCI Building Systems. The engineer whose seal appears hereon is employed by either Star Building Systems or a division of its affiliate NCI Building Systems and is not the engineer of record for this project. Cordially, Star Building Systems Materials for Metal Buildings An NCI Company Allen D. Hurtz, P.E. Director of Engineering Job Number ........................ 16-B-78515 Builder ........................... NPR HOLDINGS Jobsite Location .................. OB MUFREJ, YELM, Washington Building Code ..................... 2015 IBC Building Risk Category ............ Normal (Risk Category II) Roof Dead Load Superimposed ................. 2.48 psf Collateral ................... 3.00 psf (3.00 psf Other) Roof Live Load .................... 20.00 psf no reduction Snow Ground Snow Load (Pg) ........ 25.00 psf Snow Load Importance Factor (I) 1.00 Flat Roof Snow Load (Pf) ..... 21.00 psf (per code) Minimum Roof Snow Load (Pf) .. 25.00 psf (used in design) Snow Exposure Factor (Ce) .... 1.00 Thermal Factor (Ct) .......... 1.20 Wind Ultimate Wind Speed (Vult) ... 110.00 mph Nominal Wind Speed (Vasd) .... 85 mph (IBC section 1609.3.1) Serviceability Wind Speed .... 72 mph Wind Exposure Category ....... B Internal Pressure Coef (GCpi) 0.18/-0.18 Loads for components not provided by building manufacturer Corner Areas (within 4.00' of corner) 19.92 psf pressure -26.56 psf suction Other Areas 19.92 psf pressure -21.58 psf suction These values are the maximum values required based on a 10 sq ft area. Components with larger areas may have lower wind loads. Seismic Seismic Importance Factor (Ie) 1.00 Seismic Design Category ...... D Soil Site Class .............. D Stiff Soil Ss ........................... 1.245 g Sds ..... 0.832 g S1 ........................... 0.495 g Sd1 ..... 0.497 g Analysis Procedure ........... Equivalent Lateral Force Column Line 1 2-5 SWA & SWC Basic Force Resisting System B3 C4 B3 Response Modification Coefficient (R) 3.25 3.50 3.25 Seismic Response Coefficient (Cs) 0.256 0.238 0.256 Design Base Shear in kips (V) 1.60 5.59 6.71 Basic Structural System (from ASCE 7-10 Table 12.2-1) B3 - Ordinary Steel Concentrically Braced Frame C4 - Ordinary Steel Moment Frame 1 11/8/2018 Material properties of steel bar, plate, and sheet used in the fabrication of built-up structural framing members conform to ASTM A529, ASTM A572, ASTM A1011 SS, or ASTM A1011 HSLAS with a minimum yield point of 50 ksi. Material properties of hot rolled structural shapes conform to ASTM A992, ASTM A529, or ASTM A572 with a minimum specified yield point of 50 ksi. Hot rolled angles, other than flange braces, conform to ASTM 36 minimum. Hollow structural shapes conform to ASTM A500 grade B, minimum yield point is 42 ksi for round HSS and 46 ksi for rectangular HSS. Material properties of cold-formed light gage steel members conform to the requirements of ASTM A1011 SS Grade 55, ASTM A1011 HSLAS Grade 55 Class 1, ASTM A653 SS Grade 55, or ASTM A653 HSLAS Grade 55 Class 1 with a minimum yield point of 55 ksi. For Canada, material properties conform to CAN/CSA G40.20/G40.21 or equivalent. Bolted joints with A325 Type 1 bolts greater than 1/2" diameter are specified as pre-tensioned joints in accordance with the Specification for Structural Joints Using ASTM A325 or A490 Bolts, December 31, 2009. Pre-Tensioning can be accomplished by using the turn-of-nut method of tightening, calibrated wrench, twist-off-type tension-control bolts or direct-tension-indicator as acceptable to the Inspecting Agency and Building Official. Installation inspection requirements for pre-tensioned joints (Specification for Structural Joints Section 9.2) using turn-of-nut method is suggested. The connections on this project are not slip critical. Using 7 x 7 eave gutter with 4 x 5 downspouts, the roof drainage system has been designed using the method outlined in the MBMA Metal Building Systems Manual. Downspout locations have not been located on these drawings. The downspouts are to be placed on the building sidewalls at a spacing not to exceed 80.0 feet with the first downspout from both ends of the gutter run within 40.0 feet of the end. Downspout spacing that does not exceed the maximum spacing will be in compliance with the building code. The gutter and downspout system as provided by the manufacturer is designed to accommodate 4.0 in/hr rainfall intensity. Design criteria as noted is as given within order documents and is applied in general accordance with the applicable provisions of the model code and/or specification indicated. Neither the metal building manufacturer nor the certifying engineer declares or attests that the loads as designated are proper for local provisions that may apply or for site specific parameters. The design criteria is supplied by the builder, project owner, or an Architect and/or Engineer of Record for the overall construction project. The metal building manufacturer has not designed the structure for snow accumulation loads at the ground level which may impose snow loads on the wall framing provided by the manufacturer. This metal building system is designed as enclosed. All exterior components (i.e. doors, windows, vents, etc.) must be designed to withstand the specified wind loading for the design of components and cladding in accordance with the specified building code. 2 11/8/2018 The materials by the manufacturer will be fabricated in a facility that has received certification of accreditation for the Manufacturers of Metal Building Systems (AC472) from International Accreditation Service (IAS). This certification is recognized under Section 1704 of the IBC for approved fabricators. Framed openings, walk doors, and open areas shall be located in the bay and elevation as shown in the erection drawings. The cutting or removal of girts shown on the erection drawings due to the addition of framed openings, walk doors, or open areas not shown may void the design certifications supplied by the metal building manufacturer. The rigid frame at building B at grid line 5 is designed as a non-expandable rigid frame. Corresponding frame reactions are calculated based upon actual tributary area. 3 11/8/2018 Job Number.......................: 16-B-78515 Builder..........................: NPR HOLDINGS Jobsite Location.................: OB MUFREJ, YELM, WA The material supplied by the manufacturer has been designed with the following minimum deflection criteria. The actual deflection may be less depending on actual load and actual member length. BUILDING DEFLECTION LIMITS.......: BLDG-B Roof Limits Rafters Purlins Panels ------------------------------- -------- ------- ------ Live: L/ 180 150 60 Snow: L/ 180 180 60 Serviceability Wind: L/ 180 180 60 Total Gravity: L/ 120 120 60 Total Uplift: L/ N/A N/A 60 Frame Limits Sidesway ------------------------------- -------- Live: H/ 60 Snow: H/ 60 Serviceability Wind: H/ 60 Seismic Drift: H/ 50 Total Gravity: H/ 60 Service Seismic: H/ 50 Wall Limits Limit ------------------------------- -------- Total Wind Panels: L/ 60 Total Wind Girts: L/ 90 Total Wind EW Columns: L/ 120 The Service Seismic limit as shown here is at service level loads. 4 11/8/2018 5 11/8/2018 Star Building Systems, OKC, OK Design Summary Program User: admcaffrey Job Number: 78515B Design Summary Report Version: 7.04.3 run01 Date: 11/07/18 Start Time: 02:17:53 R:\..\16-B-78515\ver01-admcaffrey\BLDG-B\run01\78515B_bldg_B_01.cds ------------------------------------------------------------------------------- B U I L D I N G - B - D E S I G N S U M M A R Y R E P O R T All connections use ASTM A325N bolts, unless noted otherwise. All anchor rods are checked according to ASTM F1554 Gr. 36 strengths. ROOF PLANE ------- RPA R:\jobs\Active\Eng\16-B-78515\ver01-admcaffrey\BLDG-B\run01\BroofRPA_01.edf Panel .................... UDEK Panel Width .............. 24 in Panel Gage ............... 24 ga Purlins .................. 55.0 ksi Yield Strength Eave Struts .............. 55.0 ksi Yield Strength PURLIN SPACING : 4@4.6906 1.2378 Bay Length Member Size Brace L Lap R Lap # (ft) Identification Locations Exten Exten --------------------------------------------------------------------- 1 20.000 8X2.5Z16 2 points S 0.000 2.479 C 2 20.000 8X2.5Z16 2 points C 2.479 1.479 C 3 20.000 8X2.5Z16 2 points C 1.479 2.479 C 4 20.000 8X2.5Z16 2 points C 2.479 0.000 S Purlin Clip Use 2 A325 Bolts @ Level 2,3,4,5 @ Supports: 1,2,3,4,5 Purlin Stiffened Clips @ Level 2,5 @ Supports: 1,2,3,4,5 Purlin Backup Plate @ Level 2,5 @ Supports: 2,3,4 6 11/8/2018 Star Building Systems, OKC, OK Design Summary Program User: admcaffrey Job Number: 78515B Design Summary Report Version: 7.04.3 run01 Date: 11/07/18 Start Time: 02:17:53 R:\..\16-B-78515\ver01-admcaffrey\BLDG-B\run01\78515B_bldg_B_01.cds ------------------------------------------------------------------------------- ROOF PLANE ------- RPC R:\jobs\Active\Eng\16-B-78515\ver01-admcaffrey\BLDG-B\run01\BroofRPC_01.edf Panel .................... UDEK Panel Width .............. 24 in Panel Gage ............... 24 ga Purlins .................. 55.0 ksi Yield Strength Eave Struts .............. 55.0 ksi Yield Strength PURLIN SPACING : 2@4.6905 2@4.6906 1.2378 Bay Length Member Size Brace L Lap R Lap # (ft) Identification Locations Exten Exten --------------------------------------------------------------------- 1 20.000 8X2.5Z16 2 points S 0.000 2.479 C 2 20.000 8X2.5Z16 2 points C 2.479 1.479 C 3 20.000 8X2.5Z16 2 points C 1.479 2.479 C 4 20.000 8X2.5Z16 2 points C 2.479 0.000 S Purlin Clip Use 2 A325 Bolts @ Level 2,3,4,5 @ Supports: 5,4,3,2,1 Purlin Stiffened Clips @ Level 2,5 @ Supports: 5,4,3,2,1 Purlin Backup Plate @ Level 2,5 @ Supports: 4,3,2 RPC Purlin Strut @ 20.000 (ft) :8X2.5Z16 Bays 1 RPC Purlin Strut @ 20.000 (ft) :8X2.5Z16 Bays 2 RPC Purlin Strut @ 20.000 (ft) :8X2.5Z16 Bays 3 RPC Purlin Strut @ 20.000 (ft) :8X2.5Z16 Bays 4 SWA Eave Strut @ 18.000 (ft) :8X3.5E14 Bays 1 SWA Eave Strut @ 18.000 (ft) :8X3.5E14 Bays 2 SWA Eave Strut @ 18.000 (ft) :8X3.5E14 Bays 3 SWA Eave Strut @ 18.000 (ft) :8X3.5E14 Bays 4 SWC Eave Strut @ 18.000 (ft) :8X3.5E14 Bays 1 SWC Eave Strut @ 18.000 (ft) :8X3.5E14 Bays 2 SWC Eave Strut @ 18.000 (ft) :8X3.5E14 Bays 3 SWC Eave Strut @ 18.000 (ft) :8X3.5E14 Bays 4 Note: 1) All Purlin strut locations for all roof planes are measured from back sidewall. 2) All purlin strut rows use the same lap lengths as the main purlin design. Eave strut interior connection at SWA uses (2)-1/2" A325 bolts. Eave strut interior connection at SWC uses (2)-1/2" A325 bolts. Eave strut connection at end-frame uses (4)-1/2" A325 bolts. BRACING ---- Roof: 1 bay Rod Plane SWA : 1 bay Rod: Hillside Washers Plane SWC : 1 bay Rod: Hillside Washers Plane EWB : 1 bay Rod Plane EWD : End Frame 7 11/8/2018 Star Building Systems, OKC, OK Design Summary Program User: admcaffrey Job Number: 78515B Design Summary Report Version: 7.04.3 run01 Date: 11/07/18 Start Time: 02:17:53 R:\..\16-B-78515\ver01-admcaffrey\BLDG-B\run01\78515B_bldg_B_01.cds ------------------------------------------------------------------------------- SIDEWALL PLANE SWA -- ( 8.250" Inset columns ) R:\jobs\Active\Eng\16-B-78515\ver01-admcaffrey\BLDG-B\run01\BwallSWA_01.edf Panel .................... PBR Panel Width .............. 36 in Panel Gage ............... 26 ga Girts .................... 55.0 ksi Yield Strength GIRTS SPACINGS : 7'6 6'0 Bay Elev. Length Member Size Brace L Lap R Lap # (ft-in) (ft) Identification Locations Exten Exten --------------------------------------------------------------------- 1 7'6 20.000 8X2.5Z16 None S 0.000 1.479 C 2 7'6 20.000 8X2.5Z16 None C 1.479 0.000 S 3 7'6 20.000 8X2.5Z16 F.O. S 0.000 0.000 S 1 13'6 20.000 8X2.5Z16 None S 0.000 1.479 C 2 13'6 20.000 8X2.5Z16 None C 1.479 1.479 C 3 13'6 20.000 8X2.5Z16 None C 1.479 0.000 S Note : Maximum Distance To Extend Girt From Adjacent Bay is 36.00 inches. FRAMED OPENINGS: Width Height Sill Ht Jamb Header/Sill Bay Distance 10'0 8'0 N/A 8X3.5C14 8X2.5C16 3 4'1 OPEN AREAS: OPEN TO REMAIN Size Wall Distance 20'0 x 18'0 SWA 60'0 8 11/8/2018 Star Building Systems, OKC, OK Design Summary Program User: admcaffrey Job Number: 78515B Design Summary Report Version: 7.04.3 run01 Date: 11/07/18 Start Time: 02:17:53 R:\..\16-B-78515\ver01-admcaffrey\BLDG-B\run01\78515B_bldg_B_01.cds ------------------------------------------------------------------------------- SIDEWALL PLANE SWC -- ( 8.250" Inset columns ) R:\jobs\Active\Eng\16-B-78515\ver01-admcaffrey\BLDG-B\run01\BwallSWC_01.edf Panel .................... PBR Panel Width .............. 36 in Panel Gage ............... 26 ga Girts .................... 55.0 ksi Yield Strength GIRTS SPACINGS : 7'6 6'0 Bay Elev. Length Member Size Brace L Lap R Lap # (ft-in) (ft) Identification Locations Exten Exten --------------------------------------------------------------------- 2 7'6 20.000 8X2.5Z16 None S 0.000 1.479 C 3 7'6 20.000 8X2.5Z16 None C 1.479 1.479 C 4 7'6 20.000 8X2.5Z16 None C 1.479 0.000 S 2 13'6 20.000 8X2.5Z16 None S 0.000 1.479 C 3 13'6 20.000 8X2.5Z16 None C 1.479 1.479 C 4 13'6 20.000 8X2.5Z16 None C 1.479 0.000 S Note : Maximum Distance To Extend Girt From Adjacent Bay is 36.00 inches. OPEN AREAS: OPEN TO REMAIN Size Wall Distance 20'0 x 18'0 SWC 0'0 9 11/8/2018 Star Building Systems, OKC, OK Design Summary Program User: admcaffrey Job Number: 78515B Design Summary Report Version: 7.04.3 run01 Date: 11/07/18 Start Time: 02:17:53 R:\..\16-B-78515\ver01-admcaffrey\BLDG-B\run01\78515B_bldg_B_01.cds ------------------------------------------------------------------------------- Endwall Plane EWB Design ........ BEARING FRAME R:\jobs\Active\Eng\16-B-78515\ver01-admcaffrey\BLDG-B\run01\BwallEWB_01.edf Panel .................... PBR Panel Width .............. 36 in Panel Gage ............... 26 ga RAFTERS ----- Mem Description Length Start End # Member Size Identification (ft) (ft) (ft) ------------------------------------------------------------- 1 W8X10 50.0 ksi 18.959 0.000 18.959 Connections... Left : Type-IV SEP 6.000" X 3/8" (2)-1/2" A325N Bolts Right: Type-III SEP 6.000" X 3/8" (4)-1/2" A325N Bolts 2 W8X10 50.0 ksi 18.959 18.959 37.918 Connections... Left : Type-III SEP 6.000" X 3/8" (4)-1/2" A325N Bolts Right: Type-IV SEP 6.000" X 3/8" (2)-1/2" A325N Bolts Flange Braces at following purlins (horizontal distance from eave) : PLANE SWA: 14.072 FB = C TYPE PLANE SWC: 14.072 FB = C TYPE Girts ..................... 55.0 ksi Yield Strength Girts Spacings : 7'6 6'0 Bay Elev. Length Member Size Brace L Lap R Lap # (ft-in) (ft) Identification Locations Exten Exten --------------------------------------------------------------------- 1 7'6 19.312 8X2.5Z16 None S 0.000 1.479 C 2 7'6 19.312 8X2.5Z16 None C 1.479 0.000 S 1 13'6 19.312 8X2.5Z16 None S 0.000 1.479 C 2 13'6 19.312 8X2.5Z16 None C 1.479 0.000 S Note : Maximum distance to extend girt from 'adjacent bay is 36.00 inches. 10 11/8/2018 Star Building Systems, OKC, OK Design Summary Program User: admcaffrey Job Number: 78515B Design Summary Report Version: 7.04.3 run01 Date: 11/07/18 Start Time: 02:17:53 R:\..\16-B-78515\ver01-admcaffrey\BLDG-B\run01\78515B_bldg_B_01.cds ------------------------------------------------------------------------------- COLUMNS ----- ( 8.250" Bypass columns ) Col Dist. Description Base Elev Base plate design information # from left Member Size Ident. (ft) Thickness & rods ----------------------------------------------------------------------------- 1-C 0.000' W8X10 50.0 ksi 0.0000' 0.375" BP thk w/( 4)-0.625" A36 1-B 20.000' W8X10 50.0 ksi 0.0000' 0.375" BP thk w/( 4)-0.625" A36 Flange Brace @ 7.5, 13.50 elev. FB = C TYPE 1-A 40.000' W8X10 50.0 ksi 0.0000' 0.375" BP thk w/( 4)-0.625" A36 ENDWALL COLUMN TO BRIDGE CHANNEL CONNECTIONS: STRUT-TO-COLUMN CLIP COL. NO. ENDWALL PLANE 1 --------- -------------------- PLANE SWC: 1-B AT PEAK, TYPE 3 CONN.,(4)-1/2" A325N CF Brdg Channel (0.3750") (4)-3/4" A325N W8X10 COLUMN EXTENSION w/ 12.000 " LAP LENGTH; 8X2.5C12 BRIDGE CHANNEL PLANE SWA: 11 11/8/2018 Star Building Systems, OKC, OK Design Summary Program User: admcaffrey Job Number: 78515B Design Summary Report Version: 7.04.3 run01 Date: 11/07/18 Start Time: 02:17:53 R:\..\16-B-78515\ver01-admcaffrey\BLDG-B\run01\78515B_bldg_B_01.cds ------------------------------------------------------------------------------- CL 4 PARTITION ........ R:\jobs\Active\Eng\16-B-78515\ver01-admcaffrey\BLDG-B\run01\BwallEWD_01.edf Panel .................... PBR Panel Width .............. 36 in Panel Gage ............... 26 ga Girts ..................... 55.0 ksi Yield Strength Girts Spacings : 7'6 6'0 Bay Elev. Length Member Size Brace L Lap R Lap # (ft-in) (ft) Identification Locations Exten Exten --------------------------------------------------------------------- 1 7'6 19.312 8X2.5Z14 None S 0.000 0.000 S 2 7'6 19.312 8X2.5Z16 F.O. S 0.000 0.000 S 1 13'6 19.312 8X2.5Z14 None S 0.000 0.000 S 2 13'6 19.312 8X2.5Z13 None S 0.000 0.000 S FRAMED OPENINGS: Width Height Sill Ht Jamb Header/Sill Bay Distance 12'0 12'0 N/A 8X3.5C14 8X2.5C16 2 4'0 COLUMNS ----- ( 0.000" Flush columns ) Col Dist. Description Base Elev Base plate design information # from left Member Size Ident. (ft) Thickness & rods ----------------------------------------------------------------------------- 4-B 20.000' ROTATED INTERIOR FRAME COLUMN – SEE CL 4 PROFILE ENDWALL COLUMN TO BRIDGE CHANNEL CONNECTIONS: LOCATE TO INSIDE FLANGE OF COLUMN STRUT-TO-COLUMN CLIP COL. NO. ENDWALL PLANE 5 --------- -------------------- PLANE SWA: 4-B AT PEAK, TYPE 3 CONN.,(4)-1/2" A325N CF Brdg Channel (0.3750") (4)-3/4" A325N W8X10 COLUMN EXTENSION w/ 12.000 " LAP LENGTH; 8X2.5C12 BRIDGE CHANNEL PLANE SWC: 12 11/8/2018 Star Building Systems, OKC, OK Design Summary Program User: admcaffrey Job Number: 78515B Design Summary Report Version: 7.04.3 run01 Date: 11/07/18 Start Time: 02:17:53 R:\..\16-B-78515\ver01-admcaffrey\BLDG-B\run01\78515B_bldg_B_01.cds ------------------------------------------------------------------------------- Endwall Plane EWD Design ........ RIGID BEARING FRAME R:\jobs\Active\Eng\16-B-78515\ver01-admcaffrey\BLDG-B\run01\BwallEWD_01.edf OPEN AREAS: OPEN TO REMAIN Size Wall Distance 40'0 x 20’6 EWD 0'0 FRAMES ----- Type Span Live Wind Eave Trib Grid Labels CS 40.000 20.00/110.00 18.00/ 20.00 2-3 MS 40.000 20.00/110.00 18.00/ 19.42 4 MS 40.000 20.00/110.00 18.00/ 10.58 5 Note: Use square anchor rod layout. 13 11/8/2018 Building: BLDG-B CDS file name: 16-B-78515_BLDG-B_Eds2Xds.cds Eds2Xds User: admcaffrey Job Number: 16-B-78515 Oklahoma City Date: 11/07/2018 03:40:28 PM Relative path: \\OKCSNA01\TS\jobs\Active\Eng\16-B-78515 ---------------------------------------------------------------------------------------------------------------------------- Planes Name File SWA \ver01-admcaffrey\BLDG-B\run01\BwallSWA_01.edf EWD \ver01-admcaffrey\BLDG-B\run01\BwallEWD_01.edf SWC \ver01-admcaffrey\BLDG-B\run01\BwallSWC_01.edf EWB \ver01-admcaffrey\BLDG-B\run01\BwallEWB_01.edf RPA \ver01-admcaffrey\BLDG-B\run01\BroofRPA_01.edf RPC \ver01-admcaffrey\BLDG-B\run01\BroofRPC_01.edf Frames Frame Line Left Frame Left File Right Frame Right File 2 E \ver01-admcaffrey\BLDG- B\DRFTG\x02L E \ver01-admcaffrey\BLDG- B\DRFTG\x02L 3 E \ver01-admcaffrey\BLDG- B\DRFTG\x02L E \ver01-admcaffrey\BLDG- B\DRFTG\x02L 4 F \ver01-admcaffrey\BLDG- B\DRFTG\x03L F \ver01-admcaffrey\BLDG- B\DRFTG\x03L 5 G \ver01-admcaffrey\BLDG- B\DRFTG\x04L G \ver01-admcaffrey\BLDG- B\DRFTG\x04L Portal Frames Plane Name Bay Frame File 14 11/8/2018 20'1234567CCCLLLSymm.FrameI.F.WEB LEN.WEB THK.O.F.I.F.WEB LEN.WEB THK.O.F.0.1340.1850.13410.0'6.169'18.661'6X0.255X0.256X0.255X0.2510'0"6.169'8.661'10'0"16'2"18'51/2"CMCC18' E.H.1.512Star Building SystemsStar Building SystemsStar Building SystemsFRAME ID #FRAME ID #2USER NAME:USER NAME:admcaffreyDATE:DATE:11/ 7/18TIME:TIME:15:18:30PAGE:PAGE:2-18600 S. I-35, Oklahoma City, OK 73149cs 40./18./20. 20./110./25.JOB NAME:JOB NAME:78515BFILE:FILE:frames_2_3.fraLOCATION: GridlinesLOCATION:23DETAIL FILE:tive\ENG\16-B-78515\ver01-admcaffrey\BLDG-B\Drftg\x02LDETAIL FILE:BOLTS:A325 FULLY TIGHTWEIGHT:1383 lbsPURLINS(horz. from eave) :8"-Z2@4'8 5/16",2@4'8 5/16"GIRTS (vert. from floor): 8"-Z7'6",6'(8.25")(1) All sectional dimensions are in inches.(2) All Flange lengths are measured along outer flange.CONNECTION DETAILS :CONNECTION DETAILS :CONNECTION DETAILS : GRIDLINES * =23LocationLocationWeb Dep.Web Dep.TypeTypePlate(DN)PlatePlate(UP)PlateBoltsBolts11.0BASE6.0X0.375N/A(4)-3/411.0SPLICEN/AN/AN/A11.0HORZ STF2.75X0.25N/AN/AN/ACAP (EXT)6.0X0.25N/AN/A15.52E/2E6.0X0.756.0X0.75(8)-3/415.5SPLICEN/AN/AN/A15.52E/2E6.0X0.56.0X0.5(8)-3/4*-C123456715 11/8/2018 WEB THK 0.156L.F. 6 x 1/4R.F. 6 x 1/420'1234567CCCLLLSymm.Frame89I.F.WEB LEN.WEB THK.O.F.I.F.WEB LEN.WEB THK.O.F.0.1560.1340.15616.342'13.598'5.0'6X0.255X0.256X0.255X0.2510'0"6.342'13.598'5'0"16'41/8"18'03/8"CCCC18' E.H.1.512Star Building SystemsStar Building SystemsStar Building SystemsFRAME ID #FRAME ID #3USER NAME:USER NAME:admcaffreyDATE:DATE:11/ 8/18TIME:TIME:13:03:22PAGE:PAGE:3-18600 S. I-35, Oklahoma City, OK 73149ms1 40./18./19.417 20./110./25.JOB NAME:JOB NAME:78515BFILE:FILE:frame_4.fraLOCATION: GridlinesLOCATION:4DETAIL FILE:tive\ENG\16-B-78515\ver01-admcaffrey\BLDG-B\Drftg\x03LDETAIL FILE:BOLTS:A325 FULLY TIGHTWEIGHT:1647 lbsPURLINS(horz. from eave) :8"-Z2@4'8 5/16",2@4'8 5/16"GIRTS (vert. from floor): 8"-Z7'6",6'(8.25")(1) All sectional dimensions are in inches.(2) All Flange lengths are measured along outer flange.CONNECTION DETAILS :CONNECTION DETAILS :CONNECTION DETAILS : GRIDLINES * =4LocationLocationWeb Dep.Web Dep.TypeTypePlate(DN)PlatePlate(UP)PlateBoltsBolts11.5BASE6.0X0.375N/A(4)-3/411.5SPLICEN/AN/AN/A11.5HORZ STF2.75X0.25N/AN/AN/ACAP (EXT)6.0X0.25N/AN/A13.52E/2E6.0X0.756.0X0.75(8)-3/413.5SPLICEN/AN/AN/A20.67692E/1I6.0X0.3756.0X0.375(6)-3/47.5BASE6.0X0.375N/A(4)-3/47.5CAP/STF6.0X0.3752.25X0.3125(4)-1/2*-C1234567*-B8916 11/8/2018 WEB THK 0.134L.F. 6 x 1/4R.F. 6 x 1/420'1234567CCCLLLSymm.Frame89I.F.WEB LEN.WEB THK.O.F.I.F.WEB LEN.WEB THK.O.F.0.1340.1560.13410.0'6.61'13.772'5.0'6X0.255X0.256X0.255X0.2510'0"6.61'13.772'5'0"16'73/8"18'37/8"CCC18' E.H.1.512Star Building SystemsStar Building SystemsStar Building SystemsFRAME ID #FRAME ID #4USER NAME:USER NAME:admcaffreyDATE:DATE:11/ 8/18TIME:TIME:13:03:49PAGE:PAGE:4-18600 S. I-35, Oklahoma City, OK 73149ms1 40./18./10.583 20./110./25.JOB NAME:JOB NAME:78515BFILE:FILE:frame_5.fraLOCATION: GridlinesLOCATION:5DETAIL FILE:tive\ENG\16-B-78515\ver01-admcaffrey\BLDG-B\Drftg\x04LDETAIL FILE:BOLTS:A325 FULLY TIGHTWEIGHT:1531 lbsPURLINS(horz. from eave) :8"-Z2@4'8 5/16",2@4'8 5/16"GIRTS (vert. from floor): 8"-Z(8.25")(1) All sectional dimensions are in inches.(2) All Flange lengths are measured along outer flange.CONNECTION DETAILS :CONNECTION DETAILS :CONNECTION DETAILS : GRIDLINES * =5LocationLocationWeb Dep.Web Dep.TypeTypePlate(DN)PlatePlate(UP)PlateBoltsBolts9.0BASE6.0X0.375N/A(4)-3/49.0SPLICEN/AN/AN/A9.0HORZ STF2.75X0.25N/AN/AN/ACAP (EXT)6.0X0.25N/AN/A10.02E/2E8.0X0.758.0X0.75(8)-3/410.0SPLICEN/AN/AN/A17.23072E/1I6.0X0.3756.0X0.375(6)-3/411.0BASE6.0X0.375N/A(4)-3/411.0CAP/STF6.0X0.3752.25X0.3125(4)-1/2*-C1234567*-B8917 11/8/2018 Rev G 7/01/13 REACTIONS BUILDER: NPR HOLDINGS CUSTOMER: OB MUFREJ JOB NUMBER: 16-B-78515 Notes 1) The reactions provided are based on the Order Documents at the time of mailing. Any changes to building loads or dimensions may change the reactions. The reactions will be superseded and voided by any future mailing. 2) The reactions provided have been created with the following layout (unless noted otherwise). a) A reaction table is provided with the reactions for each load group. b) Rigid Frames (1) Gabled Buildings (a) Left and Right columns are determined as if viewing the left side of the building, as shown on the anchor rod drawing, from the outside of the building. (b) Interior columns are spaced from left side to right side. (2) Single Slope Buildings (a) Left column is the low side column. (b) Right column is the high side column. (c) Interior columns are spaced from low side to high side. c) Endwalls (1) Left and Right columns are determined as if viewing the wall from the outside. (2) Interior columns are spaced from left to right. d) Anchor rod size is determined by shear and tension at the bottom of the base plate. The length of the anchor rod and method of load transfer to the foundation are to be determined by the foundation engineer. e) Anchor rods are ASTM F1554 Gr. 36 material unless noted otherwise on the anchor rod layout drawing. f) X-Bracing (1) Rod Bracing reactions have been included in values shown in the reaction tables. (2) For IBC and UBC based building codes, when x-bracing is present in the sidewall, individual longitudinal seismic loads (RBUPEQ and RBDWEQ) do not include the amplification factor, 0. (3) For IBC and UBC based building codes, when x-bracing is present in the endwall, individual transverse seismic loads (EQ) do not include the amplification factor, 0. 3) Reactions are provided as un-factored for each load group applied to the column. The foundation engineer will apply the appropriate load factors and combine the reactions in accordance with the building code and design specifications to determine bearing pressures and concrete design. The factors applied to load groups for the steel column design may be different than the factors used in the foundation design. a) For projects using ultimate design wind speeds such as 2012 IBC, 2015 IBC, or 2014 Florida building code, the wind load reactions are at a strength value with a load factor of 1.0. b) For IBC codes, the seismic reactions provided are at a strength level and do not contain the rho factor. c) For NBCC codes, the seismic reactions provided do not contain the R d*Ro factor. The manufacturer does not provide "maximum" load combination reactions. However, the individual load reactions provided may be used by the foundation engineer to determine the applicable load combinations for his/her design procedures and allow for an economical foundation design. FRAME DESCRIPTION: USER NAMEiadMcaffr DATEi11/07/18 PAGEiEW-1 Endwall EWB J❑B NAME178515B FILEsREW3BLDG1 PATHS R;\,Jobs\Active\Eng\16-B-78515\ver01-adMcaffrey\BLDG-B\run01\ SUPPORT REACTIONS FOR EACH LOAD GROUP NOTE, A l l reactions are in kips and kip -ft. TIMET 141 171 52 REACTION NOTATIONS HL 1-C 1-B 1-A LOAD GROUP REACTION TABLE LOAD GROUP D DESCRIPTION DEAD L❑AD C COLLATERAL L❑AD L LIVE L❑AD S DESIGN SN❑W L❑AD SBAL BALANCED RO❑F SN❑W SUR UNBALANCED SN❑W - WIND FR❑M RIGHT T❑ LEFT SUL UNBALANCED SN❑W - WIND FR❑M LEFT T❑ RIGHT W+ WIND L❑AD AS AN INWARD ACTING PRESSURE W- WIND L❑AD AS AN OUTWARD ACTING SUCTI❑N WR WIND F❑RCE FR❑M THE RIGHT WL WIND F❑RCE FR❑M THE LEFT E+ EARTHQUAKE F❑RCE ACTING INWARD E- EARTHQUAKE F❑RCE ACTING OUTWARD ER EARTHQUAKE F❑RCE FR❑M RIGHT EL EARTHQUAKE F❑RCE FR❑M LEFT FRAME ID #2 USER NAME;admcaffreyDATE;ll/ 7/18 PAGE;2-2 I cs 40. /18. /20. 20. /110. /25. JOB NAME; 78515B FILE; frames -2-3, fra SUPPORT REACTIONS FOR EACH LOAD GROUP YALOCATI❑N; Gridllnes, 2 3 NOTES+ ( 1) A l ( react i ons are i n k i pps and k i p -ft. TIME; 15, 18, 30 (2) The seismic overstrength factor (❑mega) is not included in the 'RBDWEQ' and 'RBUPEQ' Load Group reactions. Seismic 'BASE -ONLY' combination reactions include an overstrength factor of; 2.000 (3) Primary wind load cases are not concurrent. (4) X -bracing reactions (RBPULW and RBUPEQ) are combined with LWL and LEQ groups only. REACTION NOTATIONS HL 1 VL F -1 c LOAD GROUP REACTI❑N TABLE GRIDLINES * = 2 3 COLUMN DESCRIPTION Roof Dead Load )K -C COLL )K -A Load LOAD GROUP HL VL LNL HR VR LNR DL 0. 3 1. 6 0. 0 -0.3 1.6 0. 0 C❑LL 0.3 1. 2 0. 0 -0.3 1.2 0. 0 SNOW 2. 3 10, 0 0. 0 -2. 3 10. 0 0. 0 LL 1.8 8. 0 0. 0 -1.8 8.0 0. 0 RBDWEQ -0.0 3. 0 0. 0 0.0 3.0 0. 0 EQ -0.8 -0. 7 0. 0 -0.8 0. 7 0. 0 RBUPEQ 0.0 -3. 0 -3. 4 -0.0 -3.0 -3. 4 WL 1 -3. 1 -6. 9 0. 0 -1. 4 -3. 7 0. 0 WL2 -3.6 -4. 3 0. 0 -1.0 -1.0 0. 0 WL3 1.4 -3. 7 0. 0 3. 1 -6.9 0. 0 WL4 1.0 -1. 0 0. 0 3.6 -4. 3 0. 0 LWL 1 0. 8 -5. 7 0. 0 -0. 6 -4. 8 0. 0 RBUPLW 0.0 -2. 8 -3. 1 -0.0 -2.8 -3. 1 LWL2 0.6 -4. 8 0. 0 -0.8 -5. 7 0. 0 LWL3 0.4 -3. 1 0. 0 -0. 1 -2. 1 0. 0 LWL4 0. 1 -2. 1 0. 0 -0.4 -3. 1 0. 0 RS 1.5 4. 5 0. 0 -1.5 8. 1 0. 0 LS 1.5 8, 11 0. 0 -1.5 4.5 0. 0 LOAD GROUP DL DESCRIPTION Roof Dead Load COLL Roof Collateral Load SNOW Roof Snow Load LL Roof Live Load RBDWEQ Downward Acting Rod Brace Load from Long. Seismic EQ Lateral Seismic Load [parallel to plane of frame] RBUPEQ Upward Acting Rod Brace Load from Long. Seismic WL1 Wind from Left to Right with +GCpi WL2 Wind from Left to Right with -GCpi WL3 Wind from Right to Left with +GCpi WL4 Wind from Right to Left with -GCpi LWL1 Windward Corner Left with +GCpi RBUPLW Upward Acting Rod Brace Load from Long. Wind LWL2 Windward Corner Right with +GCpi LWL3 Windward Corner Left with -GCpi LWL4 Windward Corner Right with -GCpi RS Unbalanced Right Roof Snow Load LS Unbalanced Left Roof Snow Load FRAME ID #2 USER NAME;admcaffreyDATE;ll/ 7/18 PAGE12-3 I cs 40. /18. /20. 20. /110. /25. JOB NAME; 78515B FILE; frames -2-3. fra SUPPORT REACTIONS FOR EACH LOAD GROUP wLOCATI❑N; Gridlines; 2 3 NOTES1 (1) A l l reactions are in kips and kip -ft. TIMET 15; 18; 30 (2) The seismic overstrength factor (Omega) s not included in the "RBDWEQ' and "RBUPEQ' Load Group reactions. Seismic "BASE -ONLY' combination reactions include an overstren gth factor of; 2.000 (3) Primary wind load cases are not concurrent. (4) X -bracing reactions (RBPULW and RBUPEQ) are combined with LWL and LEQ groups only. REACTION NOTATIONS VR \ F. --A- LOAD GROUP REACTION TABLE GRIDLINES x = 2 3 COLUMN )K -C -A LOAD GROUP HL VL LNL HR VR LNR RBDWLW -0. 01 2, 81 0. 0 0. 01 2. 8 0. 0 LOAD GROUP DESCRIPTION RBDWLW Downward Acting Rod Brace Load from Long. Wind FRAME ID #3 USER NAMEsadmcaffreyDATEill/ 8/18 PAGE13-2 msl 40. /18. /19. 417 20./110. JOB NAME1 78515B FILES frame -4. fro. SUPPORT REACTIONS FOR EACH LOAD GROUP YALOCATI❑N: Gridlines: 4 NOTES+ ( 1) A l l reactions are in kips and kip -ft. TIMES 131 031 22 (2) Primary wind Load cases are not concurrent. (3) X -bracing reactions (RBPULW and RBUPEQ) are combined withLWL and LEQ groups only. REACTION NOTATIONS HL f H1 � HR 1VL 1V1 �VR -C -B --A LOAD GROUP REACTI❑N TABLE GRIDLINES * = 4 COLUMN DESCRIPTION Roof Dead Load )K -C C❑LL Roof Collateral )K -A SNOW Roof Snow Load -B LL LOAD GROUP HL VL LNL HR VR LNR H1 V1 LN1 DL 0. 0 0. 8 0. 0 -0. 0 0. 8 0. 0 0. 0 1. 7 0. 0 C❑LL 0.0 0. 5 0. 0 -0.0 0.5 0. 0 -0.0 1. 3 0. 0 SNOW 0. 3 4. 3 0. 0 -0. 3 4. 3 0. 0 0. 0 10. 8 0. 0 LL 0.2 3. 4 0. 0 -0.2 3. 4 0. 0 -0.0 8. 7 0. 0 EQ -0. 8 -0, 7 0. 0 -0. 8 0. 7 0. 0 -0. 0 -0. 0 -0. 2 WL 1 -2. 1 -4. 0 0. 0 -2. 4 -0. 9 0. 0 0. 0 -5. 4 0. 0 WL2 -2. 9 -2. 5 0. 0 -1. 5 0. 7 0. 0 0. 0 -3. 4 0. 0 LWL1 1.6 -3. 4 0. 0 -1.3 -2.5 0. 0 0.0 -4.2 -3. 3 LWL2 1. 3 -2. 5 0. 0 -1. 6 -3. 4 0. 0 0. 0 -4. 2 -3. 3 LWL3 0.8 -1. 9 0. 0 -0.5 -0.9 0. 0 -0.0 -2.2 3. 3 LWL4 0.5 -0. 9 0. 0 -0.8 -1.9 0. 0 -0.0 -2.2 3. 3 WL3 2. 4 -0. 9 0. 0 2. 1 -4. 0 0. 0 -0. 0 -5. 4 0. 0 WL4 1 , 51 0. 7 0. 0 2.9 -2.5 0. 0 -0.0 -3. 4 0. 0 RS 0.2 0. 7 0. 0 -0.2 4.2 0. 0 -0. 01 7. 3 0. 0 LS 0. 21 4. 2 0. 0 -0. 2 0. 7 0. 0 0. 01 7. 31 0. 0 LOAD GROUP DL DESCRIPTION Roof Dead Load C❑LL Roof Collateral Load SNOW Roof Snow Load LL Roof Live Load EQ Lateral Seismic Load [parallel to plane of frame] WL1 Wind from Left to Right with +GCpi WL2 Wind from Left to Right with -GCpi LWL1 Windward Corner Left with +GCpi LWL2 Windward Corner Right with +GCpi LWL3 Windward Corner Left with -GCpi LWL4 Windward Corner Right with -GCpi WL3 Wind from Right to Left with +GCpi WL4 Wind from Right to Left with -GCpi RS Unbalanced Right Roof Snow Load LS Unbalanced Left Roof Snow Load FRAME ID #4 USER NAME:admcaffreyDATE:ll/ 8/18 PAGE:4-2 msl 40. /18. /10. 583 20./110. JOB NAME: 78515B FILE: frame -5. fro, SUPPORT REACTIONS FOR EACH LOAD GROUP YALOCATI❑N: Gridllnes: 5 NOTES+ ( 1) A l l react i ons are i n k i ps and k i p -ft. TIME: 13: 03: 49 (2) Primary wind load cases are not concurrent, (3) X -bracing reactions (RBPULW and RBUPEQ) are combined withLWL and LEQ groups only, REACTION NOTATIONS HL H1 � HR �VL iV1 iVR F--C--B I --A LOAD GROUP REACTI❑N TABLE GRIDLINES x = 5 COLUMN DESCRIPTION Roof Dead Load )K -C C❑LL Roof Collateral )K -A SNOW Roof Snow Load -B LL LOAD GROUP HL VL LNL HR VR LNR H1 V1 LN1 DL 0. 0 0. 6 0. 0 -0. 0 0. 6 0. 0 0. 0 1. 2 0. 0 C❑LL 0.0 0. 3 0. 0 -0.0 0. 3 0. 0 0.0 0. 7 0. 0 SNOW 0. 2 2. 3 0. 0 -0. 2 2. 3 0. 0 0. 0 6. 0 0. 0 LL 0. 1 1. 8 0. 0 -0. 1 1. 8 0. 0 0. 0 4. 8 0. 0 EQ -0.5 -0. 4 0. 0 -0.5 0. 4 0. 0 -0.0 -0.0 -0. 2 WL1 -1.8 -3. 1 0. 0 -1.8 -0. 4 0. 0 0.0 -4.2 0. 0 WL2 -2. 3 -2. 3 0. 0 -1. 3 0. 4 0. 0 0. 0 -3. 1 0. 0 LWL1 0.9 -2. 5 0. 0 -0.7 -1.6 0. 0 0.0 -3.5 -3. 3 LWL2 0.7 -1. 7 0. 0 -1.0 -2.5 0. 0 0.0 -3.5 -3. 3 LWL3 0.5 -1. 7 0. 0 -0.2 -0.8 0. 0 -0.0 -2. 3 3. 3 LWL4 0. 2 -0. 8 0. 0 -0. 5 -1. 7 0. 0 -0. 0 -2. 3 3. 3 WL3 1. 8 -0. 4 0. 0 1. 8 -3. 1 0. 0 -0. 0 -4. 2 0. 0 WL4 1.3 0. 4 0. 0 2.3 -2. 3 0. 0 -0.0 -3. 1 0. 0 RS 0. 1 0. 4 0. 0 -0. 1 2.2 0. 0 -0.0 4.0 0. 0 LS 0. 1 2. 2 0. 0 -0. 1 0. 4 0. 0 0. 0 LOAD GROUP DL DESCRIPTION Roof Dead Load C❑LL Roof Collateral Load SNOW Roof Snow Load LL Roof Live Load EQ Lateral Seismic Load [parallel to plane of frame] WL1 Wind from Left to Right with +GCpi WL2 Wind from Left to Right with -GCpi LWL1 Windward Corner Left with +GCpi LWL2 Windward Corner Right with +GCpi LWL3 Windward Corner Left with -GCpi LWL4 Windward Corner Right with -GCpi WL3 Wind from Right to Left with +GCpi WL4 Wind from Right to Left with -GCpi RS Unbalanced Right Roof Snow Load LS Unbalanced Left Roof Snow Load