Addendum no.2 12-1-03 001
City of Yelm
105 Velm Avenue W
Yelm, Washington 98597
City of Yelm, City Hall Improvements Building
December V, 2003
ADDENDUM NO. 2
This Addendum forms a part of the Contract Documents and modifies the original Contract
Documents dated November 12"', 2003 as noted below. Acknowledge receipt of this Addendum
in the space provided on the Form of Proposal. Failure to do so may subject Bidder to
disqualification.
This Addendum is issued to all known Plan Holders.
This Addendum consists of 2 pages.
ATTACHMENTS
L None
PREVIOUS ADDENDUMS
1. Addendum No. 1, dated November 21, 2003
SPECIFICATIONS
No changes
DRAWINGS
1. Sheet AL02 Wall Types Legend: Remove the entire text of all three wall types,
including modifications from Addendum No. I and replace each with text italicized
and in quotation marks below.
Firstwalltype: "Existing Walls"
GA metal studslm l6"O.C. with 518" GWB each side
Second wall type: -3Y "X' 15
& 2 % "sound hart insulation. Partition wall as.sembiv to extend continuously
front finished Jioor to underside of roof deck above (see exceptions in RLII
Type General Notes), including GWB and sound hall. Insulation, refer to
Specification section 09250.
Third wall type: "6"25 GA metal studs la. 16" O.C. with 518" GV6"B EA. Side with
2 % "sound ball insulation. Partition wall assemblies to extend eonlinuonsh'
from lni.shed floc to underside of roof deck above, including GWB and sound
bast. Insulation, refer to Spec bu ano n seslion 09250
Page 1 of 2
Addendum N2
03011 City of Yelm: City Hall Improvements
2. Sheet AL02 Wall Types Legend: Add the following text at the end of the Wall
Types Legend:
"Wall Types legend, General Notes
1. Wall assemblies in haunts 115, 116, 117, 125, 126 and 127. Wall assemblies
may letntinate at bauom chord ofscissor front) trusses. The elevation of the
underside of the trusses van, between ±9'3 " and t 11 '-6
l: Wall Assennbhes in Rooms 113, 114, 118, 122, and 123.' Elevation of the
underside of coal deck varies between 311''' 6" and t14'-6"
3. Wall assemblies in Rooms 105, 106, 107, 108, 109, 110, and 111 Elevation of
the underside of roof- deck varies heNven t9'3 " and tl l '-6 "
END OF ADDENDUM NO 2
Page 2 of 2
Addendum H2
03011 -City of Yelm: City Hall Improvements