Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20090247 Permit Pkg 121709
City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360)458-3144 Applicant: Name: RIGHT CHOICE CONSTRUCTION Address: 15004 129TH LANE SE YELM WA 98597 Property Information: Site Address: AQR~ rC~f:HR~NF ~VF SF 19 Assessor Parcel No.: 64303600700 Subdivision: Contractor Information: Name: RIGHT CHOICE CONSTRUCTION Address: DAVID RIELAND 15004 129TH LANE SE YELM WA 98597 Contractor License No.: RIGHTCC961 P7 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: SFR, PLAN #1922 LOT 19 Sq. Ft. per floor: First 840 Second Third Garage Basement Fees: Item NEW RESIDENTIAL BUILDING MECHANICAL PLUMBING 1082 711 Permit No.: 20090247 Issue Date: 12/16/2009 (Work must be started within 180 days) Phone: 360-400-0612 Owner: JOHN'S MEADOWS 50 LLC JOHNS MEADOWS Lot: 19 Phone: 360-400-0612 Expires: 12/31 /2010 Heat Type (Electric, Gas, Other): GAS Contractor RIGHT CHOICE CONSTRUCTION KLIEMANN BROS. RICK THE PLUMBER TOTAL FEES: Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applyingas-8'~ont~ctor, I further certify that I am currently registered in the State p Vllash__i _ngton Signature'f z~ ~~ _____ Date ~~ >e~ (~Cr Firm Fees $12,974.24 $ 84.75 $ 111.00 $ 13,169.99 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: File Edit Options Functions Help W .,~___ .... _ Project # 20090247 Property 9935 COCHRANE AVE SE 19 oo ~~ _ _ _._ __ Description NEW RESIDENTIAL BUILDING Issued to RIGHT CHOICE CONSTRUCTION o0 General Segments Financial ~ Property Info ~ Information ~ Comments History ~ Fookprint ~ Conditions ~ Description Segment Description Status , Fee Payments Balance NEW RESIDENTIAL BUILDING Not Started ~ iz,9~a_ z4 i,io4. zzcR' ll,s7o_ 02 ` ~MECH MECHANICAL NokStarted s4 75 s4.75 __ ,PL PLUMBING Not Started ~~~. oo ~ 111.00 __ _. -_ _ 3 records 13.169.99 _ 1,104.22CR 12.065.77 Ok ~ ~ Cancel Edit ~ johnr ~i T;; ~~~ ~~ 1 P~s °~~~ ~~ Idill :1,~ it !r..~r, ir~r1r.•nt~ ~~~ }:: _ ~~ ~~~ ~~ Y~1r~ (iFrn¢ n;. ~i C,~ i,r, : ~n,~s~ 77 ~~ ~i Lf}, ±~Ii r~~,~ a.?liil Gt+t ~va Fi.'_i ~~ /(-~ i , { ~;r; .;~ . ~r <, . t ~'1n J -~;~ 1 ' ... t... ,.,E 1 `. ,ti_ i •~ -~ 1~ a nrir[t ~.f { i_. i~..L~e . ~ ~i .1. j q =' !t2 1n ~i.IP' _ _._.... -~ _,~' ~qOZ~~ CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: 993s Cochrane Ave SE Parcel#: 64303600700 SUbdIVISIOn: JOHN'S MEADOWS LOt #: 19 Zoning; R-6 ~ New Construction -~ Re-Model / Re-Roof /Addition L Home Occupation Sign J Plumbing ._ Mechanical -Mobile /Manufactured Home Placement r~ Other PrOJect DeSCI'IptlOn/SCOpe Of Work: SINGLE FAMILY HOME Project Value: PORCH Building Area (sq. ft) 1St Floor s4o 2"d Floor 1082 Garage 711 D"`C o Basement Carport ati # Bedrooms 3 # Bathrooms? .. s Heati ~ GAS/OTHER o ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? No If yes, a completed environmental checklist must accompany permit application. BUILDING OWNER NAME: MICHAEL MASTRO ADDRESS Slo RAINER AvE S EMAIL Jimse@canyon.~ohnlscott.com CITY SEATTLE STATE WA ZIP 98144 TELEPHONE (253) 539-2217 ARCHITECT/ENGINEER Residential Group LICENSE # ADDRESS 33919 9th Ave. South, Ste. 102 EMAIL btran@residetialgrp.com CITY Federal way STATE wA ZIP98oo3 TELEPHONE (253) 835-1516 GENERAL CONTRACTOR Right choice Const. TELEPHONE (360)400-0612 ADDRESS 15004 129th Lane SE EMAIL davidrieland@comcast.net CITY Yelm STATE WA ZIP 98597 FAX (360) 400-0613 CONTRACTOR'S LICENSE #RIGHTCC961P7 EXP DATElo/1CITY LICENSE # 09-002403. o PLUMBING CONTRACTOR Rlcx THE PLUMBER TELEPHONE (253) 847-7239 ADDRESS 17711 85Th Ave E EMAIL rick@ricktheplumberco.com CITY PUYALLUP STATE WA ZIP 98373 FAX (253) 846-3137 CONTRACTOR'S LICENSE # RICKPCID32KN EXP DATES 1~ITY LICENSE # MECHANICAL CONTRACTOR KLIEMANN BROS. TELEPHONE (2s3) s37-o6ss ADDRESS 4703 116th ST E EMAIL karen@kliemannbros . com CITY TACOMA STATE wA ZIP 98446 FAX (2s3) 539-3861 CONTRACTOR'S LICENSE # KLIEMBH021BT EXP DATE 1 1~ITY LICENSE # os-001649.0 Copy of mitigation agreement with Yelm Community Schools, if applicable. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. Appli n e Date Own / ont actor / ner's Agent /Contractor's Agent (Please circle one.) All permits are non-transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days 105 Yelm Avenue West (360) 458-3 PO Box 479 (360) 458-3144 FAX Yelm, WA 98597 www.ci.yelm.w~s}~;~ ~. :_ ~~~~ DoT 19 993 5 COCK fZAN E AVE 5E PAf~CEL # 64303600700 PLAN 1922 ._, r ~ ~'• ~ ~ ~. ~~ ~~ / ~~ ~ ~ Q~~. ~ / ~~ ~~ o ,, a -". a / \ , a '[\ ~ ~, \ \~ \ ~j° / ~ /,, ~\ ~ ~`~ ~\ ~b~ ~ FI L ~- MEADOWS THURSTON COUNTY DEVELOPMENT SERVICES 2006 WSEC PRESCRIPTIVE COMPLIANCE FORM 1 >~- t ~ APPLICANT NAME: S; tPd~ ~ ~ 7 ~ ~ ~ C ~ PROJECT ADDRESS: 9935 CQChtRANE AVE SE. (Lot 19) HEATING SYSTEM TYPE (Check one): ^ Forced Air Furnace rr7 Zone Heat ^ Other: MAXIMUM HEATING SYSTEM SIZE (BTU/Hr): 34,516.25 MECHANICAL VENTILATION SYSTEM TYPE (Check one): 6d Intermittent Whole House Ventilation Using Exhaust Fans (2006 VIAQ 303.4.1) ^ Intermittent Whole House Ventilation Integrated With A Forced Air System (2006 VIAQ 303.4.2) ^ Intermittent Whole House Ventilation Using A Supply Fan (2006 VIAQ 303.4.3) ^ Intermittent Whole House Ventilation Using A Heat Recovery Ventilation System (2006 VIAQ 303.4.4) This project complies with the following: ^ The project is asingle-family residence or duplex. ^ The project is wood frame OR all the insulation is interior or exterior of the framing. ^ All building components will meet the requirements of the table below. ^ The building will meet all other provisions of the WSEC and VIAQ. WASHINGTON STATE ENERGY CODE PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS°'' (Requirements based on 2006 WSEC Table 6-1, Option IV) Glazing Glazing U-Factor Door9 Ceiling2 Vaulted Wall'Z Wall Wall Floors Slabfi Area10 % U- Ceiling' Above Int° Ext° On of Floor Vertical Overhead" Factor Grade Below Below Grade Grade Grade Unlimited 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 'Adv' denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1-inch vented airspace above the insulation . Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U-factors from Table 10-6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U-factor of U=0.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U-factors determined in accordance with NFRC 100 or as specified in Section 52 ~.5: ~ ~+~;"'' " ~`° '" 12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement. :. .. _~ ~.,~ ~, ~ ~~~ ~ THURSTON COUNTY DEVELOPMENT SERVICES 2006 WSEC PRESCRIPTIVE HEATING SYSTEM CALCULATION FORM ~ ~ d/ APPLICANT NAME: ~°•-~a'~RE~C~ ~ ; ;%"mow, INC. /~ ~ ~',~j `~ C /) ~= - ~ ~° PROJECT ADDRESS: 9935 COCHRANE AVE SE (LOT 191 .......... ~ cxnn-m INSTRUCTIONS: STEP 1: Determine TOTAL ENVELOPE COMPONENT UA. ^ Multiply the PRESCRIPTIVE U-VALUE by the AREA of each component to find the ENVELOPE COMPONENT UA. For SLAB ON GRADE, multiply the PRESCRIPTIVE SLAB F-VALUE by the SLAB PERIMETER. ^ Add the ENVELOPE COMPONENT UA's to find the TOTAL ENVELOPE COMPONENT UA. ENVELOPE COMPONENT PRESCRIPTIVE U-VALUE AREA (square feet) ENVELOPE COMPONENT UA WALL R-21 0.06 1949 116.94 FLOOR R-30 0.029 1082 31.38 VAULTED CEILING (R-30 500 SF MAX. 0.034 p CEILING R-38 0.031 1082 33.54 WINDOWS 0.35 168 58.8 DOORS 0.20 87 17.4 SKYLIGHTS 0.58 0 PRESCRIPTIVE SLAB F-VALUE SLAB PERIMETER lineal feet SLAB ON GRADE R-10 0.54 0 TOTAL ENVELOPE COMPONENT UA 258.06 STEP 2: Determine MAXIMUM HEATING SYSTEM SIZE. ^ Enter the TOTAL ENVELOPE COMPONENT UA (taken from table above) as the VALUE for both ENVELOPE COMPONENTS and DUCTS. Enter 0 (zero) as the VALUE for DUCTS if the building does not have a ducted heating system. ^ Enter the volume of conditioned space in the building, in cubic feet, as the VALUE for AIR LEAKAGE. Volume of conditioned space =Conditioned floor area x Average ceiling height. ^ Multiply each VALUE by the modifier(s) to its right to find the HEAT LOAD CONTRIBUTION for each HEAT LOSS PATH. ^ Add the HEAT LOAD CONTRIBUTION's to find the DESIGN HEAT LOAD for the building. ^ Multiply the DESIGN HEAT LOAD by 1.5 to find the MAXIMUM HEATING SYSTEM SIZE. HEAT LOSS. VALUE DT ACH ADJUSTMENT HEAT LOAD PATH DEG. F. FACTOR CONTRIBUTION ENVELOPE 06 258 53 13677.18 COMPONENTS . AIR LEAKAGE 16216 53 0.6 0.018 9282.04 DUCTS 258.06 0.2 51.61 DESIGN HEAT - LOAD 23010.83 X 1.5 = MAXIMUM HEATING SYSTEM SIZE 34,516.25 BTU/Hr 5081 YELM COMMUNITY 5CH0(L4L i ~ 20 ~~G LOCAL RECEIPT DATE ~ .~~ -J ^ Received from - ~ ~ G~ ~ ~ ©rl ~~y 11 1 . S ~~ < <.~/ 18,19 ~-~l I.ti~_.. 4.~ ~..,~f.~.i Q-~Ct'V ~ DOLLAF~ AMOUNT CASH CHECK ACCOUNT CODE Q(~~ I (~ ~ \J Yw"~ ~ ~t ~ ~~'7 I ~ ~ UNITY SCHOOLS YELAT By