Loading...
20090246 Permit Pkg 121709City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360)458-3144 Applicant: Name: RIGHT CHOICE CONSTRUCTION Address: 15004 129TH LANE SE YELM WA 98597 Property Information: Site Address: 16445 GREENBRIAR ST SE 37 Assessor Parcel No.: 56510003700 Subdivision: Contractor Information: Name: RIGHT CHOICE CONSTRUCTION Address: DAVID RIELAND 15004 129TH LANE SE YELM WA 98597 Contractor License No.: RIGHTCC961 P7 Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: SFR, PLAN #1434 LOT 37 Phone: 360-400-0612 Owner: JOHN'S MEADOWS 50 LLC JOHNS MEADOWS Lot: 37 Phone: 360-400-0612 Expires: 12/31 /2010 Sq. Ft. per floor: First 1434 Heat Type (Electric, Gas, Other) Second Third Garage 352 Basement Fees: Item Contractor NEW RESIDENTIAL BUILDING RIGHT CHOICE CONSTRUCTION MECHANICAL KLIEMANN BROS. PLUMBING RICK THE PLUMBER GAS TOTAL FEES: Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure i in conformity with all applicable City of Yelm regulations including those governing zoni~-an a~divisio and in addition, all covenants, easements and restriction cor . / p~ s a tractor, I furth r certify that I am currently registered in the,St.~e of Washingtgrr. Si nature _ =-~ ~/~f Date ~ ~ 4 )t c ~'/ Firm Permit Ivo.: 20090246 Issue Date: 12/16/2009 (Work must be started within 180 days) Fees $12,108.55 $ 71.75 $ 97.00 $ 12,277.30 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: File Edit Options Functions Help ~,~F ~-~ _ _ _ _ _ __ Project # 20090246 ~ Description NEW RESIDENTIAL BUILDING _._ Property 16445 GREENBRIAR ST SE 37 ~~~ Issued to 'RIGHT CHOICE CONSTRUCTION General ~ Segments Financial Property Info ~ Information Comments ~ History ~ Footprint Conditions Description Segment Description Status Fee Payments Balance NEW RESIDENTIAL BUILDING ' Not Started j _ iz,ios. ss' 755.13CR 11,353.42 MECH PL MECHANIC4L PLUMBING Not Started Not Started _ ~71.75 97 _ o0 ~ 71.75 97.00 3 records I 12,277.30 ' 755.13CR 11,522.17 ~. k~lt+ Edit This Record ; ~ Clear View ': iohnr i ~ ~r~4e `{~;~fi ~~ ~ ..- ..... ~~_:i_i: _... ..- ... r::. ~_.a~.~ - __ --- --- ,~ era: ~~_ ~ - .~ .... ~_l~Y ~~ ~~i(~ ~`rt D ` ~'i t L~~I'1. l!I 11. 7C~~e,~n .j~e,~;iiilt; ~JiL~.!'~~j `%~j`9j•fL~+. ^.t ;f~iJCY7ii' ~~~ 1 ,i' .. ~~i7_il,t ~I jiil~!~ n~ftn'[P~;~~fyT ~•~t~ 1G~':~- ir:C~yyIT.''sT+[ yi ter- ^n T:.~~ ~i_C~rri1 n~^ ~ ,!n~, ?~rJl irk ~f w nrl' a ^ nt err„`, __.. _._____-_.....__......F ^ ;-:~; n::-~~' to ~.'l.('}li~a li ~4~ . "`''- ~oog o 2L(, to CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: 16446 Greenbriar St . SE SUbdIVISIOn: JOHN'S MEADOWS LOt #: 37 Parcel #: 64303600700 Zoning; R-6 New Construction L Re-Model / Re-Roof /Addition ~~ Home Occupation Sign - Plumbing -Mechanical ~ Mobile /Manufactured Home Placement C Other PrOJect DeSCrlptlOn/SCOpe Of Work: SINGLE FAMILY HOME Project Value: PORCH Building Area (sq. ft) 15` Floor 1434 2"d Floor Garage 362 D"~C o Basement Carport ati # Bedrooms 3 # Bathrooms 3 Heati ~ GAS/OTHER o ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? No If yes, a completed environmental checklist must accompany permit application BUILDING OWNER NAME: MICHAEL MASTRO ADDRESS 51o RAINER AvE S EMAIL JimseCcanyon.iohnlscott.com CITY SEATTLE STATE WA ZIP 98144 TELEPHONE (253) 539-2217 ARCHITECT/ENGINEER Residential Group LICENSE # ADDRESS 33919 9th Ave. South, Ste. 102 EMAIL btran@residetialgrp.com CITY Federal way STATE wA ZIP9soo3 TELEPHONE (253)835-1516 GENERAL CONTRACTOR Right choice const. TELEPHONE (360)400-0612 ADDRESS 15004 129th Lane SE EMAIL davidrielandCCOmcast.net CITY Yelm STATE WA ZIP 98597 FAX (360) 872-8357 CONTRACTOR'S LICENSE #RIGHTCC961P7 EXP DATElo/1CITY LICENSE # 09-002403.0 PLUMBING CONTRACTOR RICK THE PLUMBER TELEPHONE (253) 847-7239 ADDRESS 17711 85Th Ave E EMAIL rickQricktheplumberco.com CITY PUYALLUP STATE WA ZIP 98373 FAX (253)846-3137 CONTRACTOR'S LICENSE # RICKPCID32KN EXP DATES 1(CITY LICENSE # MECHANICAL'CONTRACTOR KLIEMANN BROS. TELEPHONE (263) 637-o6ss ADDRESS 4703 116th ST E EMAIL karen@kliemannbros.com CITY TACOMA STATE wA ZIP 98446 FAX (253) 539-3861 CONTRACTOR'S LICENSE # KLIEMBH021BT EXP DATE1 1(CITY LICENSE # Os-001649.0 Copy of mitigation agreement with Yelm Community Schools, if applicable. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. Appli n e Date Own / ont actor / ner's Agent /Contractor's Agent (Please circle one.) All permits are non-transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days ^, m. 105 Yelm Avenue West (360) 458-383" PO Box 479 (360) 458-314 F ~„ -'~ '" i ~, ~~ Yelm, WA 98597 www.ci.yelm.wa.us- "` ` 0~ 37 1 0445 G~CENBF~IA~ ST. ~E PA(~CEL # 64303600700 PLAN 1434 ~, a SCALE: I :20 i ~ ~' i , i i i i i i e \ ~ ~. ~ ,c 1 ,.Q / ~ / ~~ / / v f ~`~ ,\ \ F~ ,/ t ~ a / ~ / ~~ f ~`~ ~ \ ~ ~ti O ~~'' / b ~'~, ~ ~' L r ~ `'~` ~ /'~ ; i } € ? ` \ ~..,r ~ E r Ef ~ 0 {..ri ~.~.~. ~ ; ~f S t ...! t,~^' I 1..~~ L.e.s' if I 0 E i G~ i.,.._ ! B ~/ ~~_ _i~W~.._ .._ 0 ,~o _. JONN'S MEADOWS THURSTON COUNTY DEVELOPMENT SERVICES 2006 WSEC PRESCRIPTIVE COMPLIANCE FORM z'tnnv crnn~rrY n i i i n r ~ ~.-~~.c .: ~ .(/ ~ era as APPLICANT NAME: ~~~ rtt7ivrt~, INC. / \ , ~' ~ fi C-- t~.~ C f' PROJECT ADDRESS: 16445 GreeAbriar St. SE. (Lot 37) HEATING SYSTEM TYPE (Check one): ^ Forced Air Furnace ~ Zone Heat ^ Other: MAXIMUM HEATING SYSTEM SIZE (BTU/Hr): 29,453.28 MECHANICAL VENTILATION SYSTEM TYPE (Check one): ~ Intermittent Whole House Ventilation Using Exhaust Fans (2006 VIAQ 303.4.1) ^ Intermittent Whole House Ventilation Integrated With A Forced Air System (2006 VIAQ 303.4.2) ^ Intermittent Whole House Ventilation Using A Supply Fan (2006 VIAQ 303.4.3) ^ Intermittent Whole House Ventilation Using A Heat Recovery Ventilation System (2006 VIAQ 303.4.4) This project complies with the following: ^ The project is asingle-family residence or duplex. ^ The project is wood frame OR all the insulation is interior or exterior of the framing. ^ All building components will meet the requirements of the table below. ^ The building will meet all other provisions of the WSEC and VIAQ. WASHINGTON STATE ENERGY CODE PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS°'' Re uirements based on 2006 WSEC Table 6-1, O tion IV Glazing Glazing U-Factor Door° Ceiling2 Vaulted Wall12 Wall Wall Floors Slabs Area10 % U- Ceiling' Above Int' Ext` On of Floor Vertical Overhead" Factor Grade Below Below Grade Grade Grade Unlimited 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 'Adv' denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1-inch vented airspace above the insulation . Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U-factors from Table 10-6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U-factor of U=0.40 or less is not included in glazing area limitations. ~-~ 11. Overhead glazing shall have U-factors determined in accordance with NFRC 100 or as specified in Section 50 1.~!;~ ~ ~ ,~, <t °~...:. 12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement. - _ ~ ~- ~~~ i THURSTON COUNTY DEVELOPMENT SERVICES 2006 WSEC PRESCRIPTIVE HEATING SYSTEM CALCULATION FORM ~ . ., ~ txxurrt~ APPLICANT NAME: ~~ e 5 k T ~ ~ ~' ~ PROJECT ADDRESS: 16445 GREENBRIAR ST. SE (LOT 3 ) INSTRUCTIONS: STEP 1: Determine TOTAL ENVELOPE COMPONENT UA. ^ Multiply the PRESCRIPTIVE U-VALUE by the AREA of each component to find the ENVELOPE COMPONENT UA. For SLAB ON GRADE, multiply the PRESCRIPTIVE SLAB F-VALUE by the SLAB PERIMETER. ^ Add the ENVELOPE COMPONENT UA's to find the TOTAL ENVELOPE COMPONENT UA. ENVELOPE COMPONENT PRESCRIPTIVE U-VALUE AREA (square feet) ENVELOPE COMPONENT UA WALL R-21 0.06 1349 80.94 FLOOR R-30 0.029 1434 41.58 VAULTED CEILING (R-30 500 SF MAX. 0.034 0 CEILING R-38 0.031 1434 44.54 WINDOWS 0.35 134.5 47.08 DOORS 0.20 79.5 15.9 SKYLIGHTS 0.58 0 PRESCRIPTIVE ' SLAB F-VALUE SLAB PERIMETER lineal feet SLAB ON GRADE R-10 0.54 0 TOTAL ENVELOPE COMPONENT UA 230.04 STEP 2: Determine MAXIMUM HEATING SYSTEM SIZE. ^ Enter the TOTAL ENVELOPE COMPONENT UA (taken from table above) as the VALUE for both ENVELOPE COMPONENTS and DUCTS. Enter 0 (zero) as the VALUE for DUCTS if the building does not have a ducted heating system. ^ Enter the volume of conditioned space in the building, in cubic feet, as the VALUE for AIR LEAKAGE. Volume of conditioned space =Conditioned floor area x Average ceiling height. ^ Multiply each VALUE by the modifier(s) to its right to find the HEAT LOAD CONTRIBUTION for each HEAT LOSS PATH. ^ Add the HEAT LOAD CONTRIBUTION's to find the DESIGN HEAT LOAD for the building. ^ Multiply the DESIGN HEAT LOAD by 1.5 to find the MAXIMUM HEATING SYSTEM SIZE. HEAT LOSS- VALUE DT ACH ADJUSTMENT HEAT LOAD PATH DEG. F. FACTOR CONTRIBUTION ENVELOPE 230 04 53 12192.12 COMPONENTS . AIR LEAKAGE 12906 53 0.6 0.018 7,397.39 DUCTS 230.04 0.2 46.01 DESIGN HEAT LOAD 19645.52 X 1.5 = MAXIMUM HEATING SYSTEM SIZE 29,453.28 BTU/H r 50~r1 YELM COMMUNITY SCH020^ L i ~ 20~ LOCAL RECEIPT DATE Received from ~ .... ~~ ~,`~~ ~ -'V ,y~F,O~~R ~ ~ -] ~ ©pTl 1 1 ~ ~L.iJf ~ ~I ~ `.1/ ~ V- 1O1~ ~~~ ~~_r ~~ ~ v~fM1 C1-~C1N DOLLA AMOUNT CASH CHECK I ~ ~ ~ (~1,:7 ACCOUNT CODE 1 ~~ `) ~ l/S(-7( )~""~ - ~-~. ~j/ ~/ ~ ~ yEL~-~ ~ UNITY SCHOOLS ~t By