20090194 Roof Framing Plans 061608TRUSSES PEP PLAN
10d ~ 6" O.C.
ROOF SHEATHING
WI NDOW l DOOR
FRAMING
WINDOW /DOOR
HEADER
WELLER CONSULTING
ENGINEERS, P.C.
21925 8TH PL W • BOTHELL, WA 98021
PH. (425) 488 - 9868 • FAX (425) 486 - 6715
DETAIL A
VENTED BLOCKING
H1 C~ 24" O.C.
r
J
Q
Q
W
S
W
J
F-
U
w
W
JOI3 NAME DONA /PLAN 3072
JOE3 NUME3ER 08-062 PREPARED E3Y MW
DA"i'E 6 / 16 / 08 SHEET NO.:~ '~ OF t~i
PROVIDE (2) ROWS OF
8d C~ 2" O.G. SHEAR
WALL TO HEADER
DETAIL 6
WELLER CONSUL"f ING
ENGINEERS, P.C.
21925 8TH PL W • BOTHELL, WA 98021
PH. (425) 488 - 9868 • FAX (425) 486 - 6715
w
Q
Q
w
w
~-
U
W
LL
w
W
JOB NAMF, DONA /PLAN 3072
JOB NUMBER 08-062 PREPARED BY MW
DATE 6 / l6 / 08 SHEET NO. ~__`=~ OF t...:r
WINDOW /DOOR
HEADER
WINDOW /DOOR
FRAMING
ADD C516 STRAP FULL
WIDTH OF SHEAR WALL
PLUS 16" END LENGTH,
TYP.
PROVIDE 2 x _
BLOCKING BEHIND
C516 STRAP, TYP.
DETAIL C
WELLER CONSULTING
ENGINEERS, P.C.
21925 8TH PL W • BOTHELL, WA 98021
PE{. (425) 48$ - 9868 • FAX (42S) 486 - 67l S
(2) 2 x _ HF # 2STUDS
PHD6 HOEDOWN
~/8" Q ALL-THREAD
RIM JOIST W/ SOLID BLOCKING
P.T. SILL PLATE
JOB NAME DONA !PLAN 3072
JOB NUMBF,R 08-062 PREPARED BY MW
DA"I'E 6 / 16 / 08 SHEET NO. ~~ OF ~_
(2)2x_HF#2STUDS
HTT 22 HOEDOWN
5/g' ~ ALL-THREAD
(OK TO SU6STITUTE SSTB24)
S.E.T. EPOXY GROUT
PER MANUFACTURERS
RECOMMENDATIONS
RIM JOIST W/ SOLID BLOCKING
SILL PLATE
DETAIL D
COUPLER AS REQUIRED
~/8' f~i WEDGE-ALL
(OK TO SUBSTITUTE
SSTB28)
(2)2x_HF#2STUDS
HTT 22 HOEDOWN
5/8".6'7 ALL-THREAD
(OK TO SUBSTITUTE SSTB24)
S.E.T. EPOXY GROUT
PER MANUFACTURERS
RECOMMENDATIONS
P.T. SILL PLATE
I - a
c0 ° a <
a
'k~ a
°a
J
O
DETAIL F
a ~~ a
a
- a a
d I~ a d
~ d
DETAIL E
WELLER CONSULTING
ENGINEERS, P.C.
21925 8TH PL W • BOTHELL, WA 98021
PH. (425) 488 - 9868 • FAX (425) 486 - 6715
4x6DF#2
HDQS HOEDOWN
~/8'.C~ ALL-THKEAD
S.E.T. EPOXY GROUT
PER MANUFACTUKEf~S
PECOMMENDATIONS
RIM J015T W/ 50LID BLOCKING
51LL PLATE
a a
`Io a
a
'K~ _ a
a
0
a~
d
JOB NAME DONA /PLAN 3072
JOB NUMBER 08-062 PREPARED BY MW
DATE 6 / 16 / 08 SHEET NO. =~; OF L4 ~
DETP~IL G
N
,4,i.`
~~ W
~I
~~
3
v
1
ti~
~/~ M. I _
...~
J
!~ Q
A
~ ~
•- O ~ O
~ ~ O o w
~C~ U C7 Z ~
'r 0 W Z ~1
O ,.~ Z ~
~ Q '4
O O Q
~ O
O _ ~ ~ w O
~ ~ w ~ U J
O ~
v~o c
n ~ a
.
N O n N J W F- -1
WELLER CONSULTING
ENGINEF,RS, P.C.
2]925 8TH PL W • BOTHELL, WA 98021
PH. (425) 488 - 9868 • FAX (425) 486 - 671 S
3/8".~CAPPIAGE BOLTS
C~ 32" O.C. STAGGEPED
EACH SIDE OF THE WEB
2 X _ HF # 2 TOP PLATE
AS PEQUIPED
(TO MATCH FLANGE WIDTH)
2 X _ HF # 2 BOTTOM PLATE
AS PEQUIPED
(TO MATCH FLANGE WIDTH)
3!8" Ql CAPPIAGE 80LT5
C~ 48" O.C. STAGGEPED
EACH SIDE OF THE WEB
GrEEL BEAM PEP PLAN
" B x 6" LAG BOLT
,CH 51DE OF WEB
i5T PEP PLAN
DETAIL 52
JOB NAME DOHA /PLAN 3072
JOB NUMBER 08-062 PREPARED BY MW
DATE 6 ! l6 ! 08 SHEET NO. '~ =~; _ OF
DETAIL 51
~/ ({.,
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 ROOF FRAMING
GT1 (FOR REACTIONS ONLY) Date: 6/14/08
Selection 3-1/8x 27 GLB 24F-V4 DFIDF Lu = 0.0 Ft
Conditions
Min Bearing Area R1= 14.7 inz R2= 14.7 inz DL Defl 0.40 in Suggested Camber 0.60 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Beam Span 28.0 ft Reaction 1 LL 5775 # Reaction 2 LL 5775 #
Beam Wt per ft 20.5 # Reaction 1 TL 9527 # Reaction 2 TL 9527 #
Bm Wt Included 574 # Maximum V 9527 #
Max Moment 66689 '# Max V (Reduced) 7996 #
TL Max Defl L / 240 TL Actual Defl L 1330
LL Max Defl L / 360 LL Actual Defl L / 544
Section (in') Shear (inz) TL Defl (in) LL Defl
379.69 84.38 1.02 0.62
354.20 49.97 1.40 0.93
OK OK OK OK
93% 59% 73% 66%
ro tpsil rv (psi) t (psi x mn) I-c ~ (psi)
Base Values 2400 240 1.8 650
Base Ad'usted 2259 240 1.8 650
Cv Volume 0.941
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 413 Uniform TL: 660 = A
Uniform Load A
0
R1 = 9527 R2 = 9527
SPAN = 28 FT
Uniform and partial uniform loads are Ibs per lineal ft.
`,/ ~(
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 ROOF FRAMING
GT2 (FOR REACTIONS ONLl7 Date: 6/14/08
Selection 3-1/8x 18 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions
Min Bearing Area R1= 3.4 in2 R2= 3.4 in2 DL Defl 0.57 in Suggested Camber 0.86 in
Dafa
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Beam Span 33.0 ft Reaction 1 LL 1238 # Reaction 2 LL 1238 #
Beam Wt per ft 13.67 # Reaction 1 TL 2206 # Reaction 2 TL 2206 #
Bm Wt Included 451 # Maximum V 2206 #
Max Moment 18196'# Max V (Reduced) 2005 #
TL Max Defl L / 240 TL Actual Defl L / 304
LL Max Defl L / 360 LL Actual Defl L / 542
Section (in') Shear (in2) TL Defl (in) LL Defl
168.75 56.25 1.30 0.73
82.03 10.90 1.65 1.10
OK OK OK OK
49% 19% 79% 66%
ro tpsi) rv (psi) t (psi x mil) Fc i (psi)
Base Values 2400 240 1.8 650
Base Ad'usted 2662 276 1.8 650
Cv Votume 0.964
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 75 Uniform TL: 120 = A
Uniform Load A
Q
R1 = 2206 R2 = 2206
SPAN = 33 FT
Uniform and partial uniform loads are Ibs per lineal ft.
~~`;
BeamChek v20051icensed to: Weller Consulting Engineers, P. C. Reg # 5234-65//y
DONA /PLAN 3076 ROOF FRAMING
GT3 (FOR REACTIONS ONLY) Date: 6/14!08
Selection 3-1/8x 13-112 GLB 24F-V4 DFIDF Lu = 0.0 Ft
Conditions
Min RPafln(] Area R1= 2.4 in2 R2= 2.4 in2 DL Defl 0.57 in Suggested Camber 0.86 in
Data
Beam Span 28.0 ft Reaction 1 LL 875 # Reaction 2 LL 875 #
Beam Wt per ft 10.25 # Reaction 1 TL 1544 # Reaction 2 TL 1544 #
Bm Wt included 287 # Maximum V 1544 #
Max Moment 10805'# Max V (Reduced) 1419 #
~
TL Max Defl L ! 240 TL Actua{ Defl L / 255
I
LL Max Defl L / 360 LL Actual Defl L / 449
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Section (in') Shear (inZ) TL Defl (in) LL Uetl
94.92 42.19 1.32 0.75
46.98 7.71 1.40 0.93
OK OK OK OK
49% 18% 94% 80%
Fb (psi) Fv (psi) t (psi x mu) rc! tpsi!
Base Values 2400 240 1.8 650
Base Ad'usted 2760 276 1.8 650
Cv Volume 1.000
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 63 Uniform TL: 100 = A
Uniform Load A
R ~44
R 1 = 1544
SPAN = 28 FT
Uniform and partial uniform loads are Ibs per lineal ft.
~..1
BeamChek v20051icensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 ROOF FRAMING
GT4 (FOR REACTIONS ONLY) Date: 6/14/08
Selection 3-1t8x 25-1/2 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions
Min Bearing Area R1= 11.9 inzR2= 14.7 inz DL Defl 0.60 in Suggested Camber 0.89 in
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span 28.0 ft Reaction 1 LL 3565 # Reaction 2 LL 5510 #
Beam Wt per ft 19.36 # Reaction 1 TL 7709 # Reaction 2 TL 9560 #
Bm Wt Included 542 # Maximum V 9560 #
Max Moment 67256'# Max V (Reduced) 8116 #
TL Max Defl L ! 240 TL Actual Defl L / 262
LL Max Defl L / 360 LL Actual Defl L ! 490
Section (in'} Shear (ins) TL Uetl (in) LL Uetl
338.67 79.69 128 0.69
308.85 44.11 1.40 0.93
OK OK OK OK
91% 55% 91% 73%
Values
Adjustments
Fb (psi) Fv (psq t (psi x miq rc! tpsi/
Base Values 2400 240 1.8 650
Sase Ad'usted 2613 276 1.8 650
Cv Volume 0.947
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Loads
Point TL Distance Par Unif LL Par Unif TL Start End
B = 2206 6.0 413 H = 660 6.0 28.0
H
Pt loads:
R1 -7709 R2 -9560
SPAN = 28 FT
Uniform and partial uniform loads are Ibs per lineal ft.
v»
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65iiy
DONA /PLAN 3076 ROOF FRAMING
TYPICAL HEADER Date: 6/14/08
Selection 4x 8 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2001
Min RParln^ Area R1= 3.1 in2 R2= 3.1 in2 DL Defl 0.03 in
Data
Beam Span 5.5 ft Reaction 1 LL 1203 # Reaction 2 LL 1203 #
Beam Wt per ft 6.17 # Reaction 1 TL 1942 # Reaction 2 TL 1942 #
Bm Wt Included 34 # Maximum V 1942 #
Max Moment 2670'# Max V (Reduced) 1515 #
TL Max Defl L ! 240 TL Actual Defl L / 809
LL Max Defl L ! 360 LL Actual Defl L / > 1000
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Section (in') Shear {in2) TL Defl (in) LL Detl
30.66 25.38 0.08 0.05
23.81 10.98 0.28 0.18
OK OK OK OK
78% 43% 30% 28%
Fb (psi) Fv (psi) E (psi x miq rc! tpsil
Base Values 900 180 1.6 625
Base Ad'usted 1346 207 1.6 625
CF Size Factor 1.300
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 438 Uniform TL: 700 = A
Uniform Load A
R ~42
R1 = 1942
SPAN = 5.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
u
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 ROOF FRAMING
H1 (ELEV A) Date: 6/14/08
Selection 3-1/8x 9 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions
Min Bearino Area R1= 4.6 inz R2= 4.6 inz DL Defl 0.09 in Suggested Camber 0.14 in
Data
Beam Span 8.5 ft Reaction 1 LL 1859 # Reaction 2 LL 1859 #
Beam Wt per ft 6.83 # Reaction 1 TL 3004 # Reaction 2 TL 3004 #
Bm Wt Included 58 # Maximum V 3004 #
Max Moment 6384'# Max V (Reduced) 2474 #
TL Max Defl L / 240 TL Actual Defl L t 421
LL Max Defl L / 360 LL Actual Defl L ! 679
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Section (in') Shear (inz) TL Defl (in) LL Detl
42.19 28.13 0.24 0.15
27.75 13.45 0.43 0.28
OK OK OK OK
66% 48% 57% 53%
Fb (psi) Fv (psi) t (psi x mil) rc! (psil
Base Values 2400 240 1.8 650
Base Ad'usted 2760 276 1.8 650
Cv Volume 1.000
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 438 Uniform TL: 700 = A
Uniform Load A
0 0
R 1 = 3004 R2 = 3004
SPAN = 8.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
Ve }
BeamChek v20051icensed fo: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 ROOF FRAMING
H1 (ELEV B) Date: 6/14/08
Selection 3-1 /8x 9 GLB 24F-V4 DF/OF Lu = 0.0 Ft
Conditions
Min Bearing Area R1= 5.5 inz R2= 5.2 inZ DL Defl 0.19 in Suggested Camber 0.28 in
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span 8.5 ft Reaction 1 LL 1177 # Reaction 2 LL 1770 #
Beam Wt per ft 6.83 # Reaction 1 TL 3597 # Reaction 2 TL 3377 #
Bm Wt Included 58 # Maximum V 3597 #
Max Moment 8069'# Max V (Reduced) 3532 #
~ TL Max Defl L ! 240 TL Actual Defl L / 313
LL Max Defl L / 360 LL Actual Defl L l 734
Section (in') Shear (n~) TL Uetl (in) LL Ue11
42.19 28.13 0.33 0.14
35.08 19.19 0.43 0.28
OK OK OK OK
83% 68% 77% 49%
Values
Adjustments
Fb (psi) Fv (psq t (psi x mn) rc! tpsil
Base Values 2400 240 1.8 650
Base Ad~usted 2760 276 1.8 650
Cv Volume 1.000
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Loads
Point TL Distance Par Unif LL Par Unif TL Start End
B = 2206 2.0 50 H = 80 0 2.0
438 I = 700 2.0 8.5
I
H
Pt loads:
R1 = 3597 R2 = 3377
SPAN = 8.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
~i
BeamChek v2005 licensed to: Wetler Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 ROOF FRAMING
H2 Date: 6/14/08
Selection 4x 10 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2001
Min Bearino Area R1= 4.2 inz R2= 2.8 inz DL Defl 0.04 in
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span 5.5 ft Reaction 1 LL 938 # Reaction 2 LL 404 #
Beam Wt per ft 7.87 # Reaction 1 TL 2623 # Reaction 2 TL 1771 #
Bm Wt Included 43 # Maximum V 2623 #
Max Moment 4538 '# Max V (Reduced) 2078 #
TL Max Defl L / 240 TL Actual Defl L / >1000
LL Max Defl L / 360 LL Actual Defl L / >1000
Section (in') Shear (inz) TL Defl (in) LL uetl
49.91 32.38 0.06 0.01
43.84 15.06 0.28 0.1$
OK OK OK OK
88% 47% 21% 8%
Values
Adjustments
Fb (psi) Fv (psi) t (psi x mn) rc! (psi)
Base Values 900 180 1.6 625
Base Ad'usted 1242 207 1.6 625
CF Size Factor 1.200
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Loads
Point TL Distance Par Unif LL Par Unif TL Start End
B = 2206 2.75 438 H = 700 0 2.75
50 I = 80 2.75 5.5
I
H
Pt loads:
0
R1 = 2623 R2 = 1771
SPAN = 5.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
Vt4G
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 UPPER FLOOR FRAMING
TYPICAL JOIST Date: 6/14/08
Selection 2x 10 HF #2 @ 16 in. oc Lu = 0.0 Ft
Conditions Repetitive Use, NDS 2001
Min Bearing Area R1= 1.2 in2 R2= 1.2 in2 DL Defl 0.09 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Beam Span 14.0 ft Reaction 1 LL 373 # Reaction 2 LL 373 #
Beam Wt per ft 0 # Reaction 1 TL 467 # Reaction 2 TL 467 #
Bm Wt Included 0 # Maximum V 467 #
Max Moment 1633'# Max V (Reduced) 415 #
TL Max Oefl L / 240 TL Actua- Defl L / 376
LL Max Defl L / 360 LL Actual Defl L / 469
Section (in') Shear (inZ) TL Defl (in) LL Defl
21.39 13.88 0.45 0.36
18.23 4.15 0.70 0.47
OK OK OK OK
85% 30% 64% 77%
ro tpsi) rv (psi) t (psi x miq t-c! (psi)
Base Values 850 150 1.3 405
Base Ad~usted 1075 150 1.3 405
CF Size Factor 1.100
Cd Duration 1.00 1.00
Cr Repetitive 1.15
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 53 Uniform TL: 67 = A
Uniform Load A
0
R1 = 467 R2 = 467
SPAN = 14 FT
Uniform and partial uniform loads are Ibs per lineal ft.
of
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 UPPER FLOOR FRAMING
TYPICAL HEADER Date: 6!14108
Selection 4x 8 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2001
Min Bearing Area R1= 1.9 inZ R2= 1.9 ins DL Defl 0.04 in
Data
Beam Span 8.5 ft Reaction 1 LL 935 # Reaction 2 LL 935 #
Beam Wt per ft 6.17 # Reaction 1 TL 1195 # Reaction 2 TL 1195 #
Bm Wt Included 52 # Maximum V 1195 #
Max Moment 2539'# Max V (Reduced) 1025 #
TL Max Deft L / 240 TL Actual Defl L / 550
LL Max Defl L / 360 LL Actual Defl L / 703
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Section {in') Shear (in2) TL Defl (in) LL Defl
30.66 25.38 0.19 0.15
26.04 8.54 0.43 028
OK OK OK OK
85% 34% 44% 51%
Fb (psi) Fv (psi) E (psi x mil) Fc! (psi)
Base Values 900 180 1.6 625
Base Ad~usted 1170 180 1.6 625
CF Size Factor 1.300
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 220 Uniform TL: 275 = A
Uniform Load A
0 0
R1 = 1195 R2 = 1195
SPAN = 8.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
0
BeamChek v2005 licensed to: Welter Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3072 UPPER FLOOR FRAMING
H3 Date: 6/15108
Selection 4x 10 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2001
Min Bearing Area R1= 4.8 inZ R2= 2.6 inz DL Defl 0.05 in
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span 6.5 ft Reaction 1 LL 1083 # Reaction 2 LL 894 #
Beam Wt per ft 7.87 # Reaction 1 TL 3002 # Reaction 2 TL 1654 #
Bm Wt Included 51 # Maximum V 3002 #
Max Moment 4395 '# Max V (Reduced) 2784 #
TL Max Defl L / 240 TL Actual Defl L / 895
LL Max Defl L / 360 LL Actual Defl L / >1000
Values
Adjustments
Section {in') Shear (in2) TL Defl (in) LL Defl
49.91 32.38 0.09 0.04
42.47 20.17 0.33 0.22
OK OK OK OK
85% 62% 27% 17%
t-b (psi) F-v (psi) E (psi x mil) Fc ~ (psi)
Base Values 900 180 1.6 625
Base Ad'usted 1242 207 1.6 625
CF Size Factor 1.200
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Loads Uniform LL: 220 Uniform TL: 275 = A
Point TL Distance Par Unif LL Par Unif TL Start End
B = 1942 1.5 438 H = 700 1.5 2.75
Uniform Load A
Pt loads:
0
R1 = 3002 R2 = 1654
SPAN = 6.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
7
j
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3072 UPPER FLOOR FRAMING
H4 (ELEV A) Date: 6/15/08
Selection 3-1/8x 9 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions
Min Bearing Area R1= 5.1 in2 R2= 3.6 in2 DL Defl 0.05 in Suggested Camber 0.07 in
Data
Attribufes
Actual
Critical
Status
Ratio
Beam Span 5.5 ft Reaction 1 LL 1617 # Reaction 2 LL 1016 #
Beam Wt per ft 6.83 # Reaction 1 TL 3327 # Reaction 2 TL 2365 #
Bm Wt Included 38 # Maximum V 3327 #
Max Moment 5248'# Max V (Reduced) 2553 #
TL Max Defl L / 240 TL Actual Defl L / 871
LL Max Defl L / 360 LL Actual Defl L / >1000
Section (in') Shear (in2) TL Defl (in) LL Defl
42.19 28.13 0.08 0.03
22.82 13.88 0.28 0.18
OK OK OK OK
54% 49% 28% 16%
Values
Adjustments
ro tpsil rv tpsi/ t tpsi x mu/ rc! tpsil
Base Values 2400 240 1.8 650
Base Ad'usted 2760 276 1.8 650
Cv Volume 1.000
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Loads Uniform LL: 260 Uniform TL: 325 = A
Point TL Distance Par Unif LL Par Unif TL Start End
B = 1942 2.75 438 H = 700 0 2.75
H
Uniform Load A
Pt loads:
0 0
R1 = 3327 R2 = 2365
SPAN = 5.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
v~ ~~
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3072 UPPER FLOOR FRAMING
H4 (ELEV B) Date: 6/15/08
Selection 3-118x 9 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions
Min Bearing Area R1= 5.6 inz R2= 4.2 inZ DL Defl 0.06 in Suggested Camber 0.09 in
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span 5.5 ft Reaction 1 LL 1617 # Reaction 2 LL 1016 #
Beam Wt per ft 6.83 # Reaction 1 TL 3668 # Reaction 2 TL 2705 #
Bm Wt Included 38 # Maximum V 3668 #
Max Moment 6185 '# Max V (Reduced) 2894 #
TL Max Defl L / 240 TL Actual Defl L / 753
LL Max Defl L / 360 LL Actual Defl L / >1000
Values
Adjustments
Section (in') Shear (in2) TL Defl (in) LL Defl
42.19 28.13 0.09 0.03
26.89 15.73 0.28 0.18
OK OK OK OK
64% 56% 32% 16%
ro tpsil rv tpsil t tps~ x mnl rc! tpsil
Base Values 2400 240 1.8 650
Base Ad'usted 2760 276 1.8 650
Cv Volume 1.000
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Loads Uniform LL: 260 Uniform TL: 325 = A
Point TL Distance Par Unif LL Par Unif TL Start End
B = 2623 2.75 438 H = 700 0 2.75
H
Uniform Load A
Pt loads:
0 0
R1 = 3668 R2 = 2705
SPAN = 5.5 FT
Uniform and partial uniform loads are fbs per lineal ft.
V~~~
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 UPPER FLOOR FRAMING
H5 Date: 6/14/08
Selection 3-1/2x 18 2.0E TJ Parallam E.S. PSL Lu = 0.0 Ft
Conditions
Min Bearing Area R1= 11.3 in2R2= 11.3 inZ DL Defl 0.18 in
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span 16.5 ft Reaction 1 LL 5569 # Reaction 2 LL 5569 #
Beam Wt per ft 19.69 # Reaction 1 TL 8495 # Reaction 2 TL 8495 #
Bm Wt included 325 # Maximum V 8495 #
Max Moment 35042 '# Max V (Reduced) 6950 #
TL Max Defl L ! 240 TL Actual Defl L 1377
~
LL Max Defl L / 360 LL Actual Defl L / 576
Section (in') Shear (in2) TL Defl (in) LL Defl
189.00 63.00 0.53 0.34
131.90 31.26 0.83 0.55
OK OK OK OK
70% 50% 64% 63%
Values
Adjustments
Fb (psi) Fv (psi) E (psi x mil) rc! (psil
Base Values 2900 290 2.0 750
Sase Ad'usted 3188 334 2.0 750
CF Size Factor 0.956
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
Cf Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Loads Uniform LL: LUU unirorm I L L~U = H
Par Unif LL Par Unif TL Start End
475 H = 760 0 16.5
H
Uniform Load A
R ~95
R 1 = 8495
SPAN = 16.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
v~~~~
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 UPPER FLOOR FRAMING
N6 Date: 6/14/08
Selection 4x 10 DF-L #2 Lu = 0.0 Ft _
Conditions NDS 2001
Min Searing Area R1= 3.3 in2 R2= 3.3 in2 DL Defl 0.03 in
Data
Beam Span 8.0 ft Reaction 1 LL 1600 # Reaction 2 LL 1600 #
Beam Wt per ft 7.87 # Reaction 1 TL 2031 # Reaction 2 TL 2031 #
Bm Wt Included 63 # Maximum V 2031 #
Max Moment 4063 '# Max V (Reduced) 1640 #
TL Max Defl L / 240 TL Actual Defl L / 759
~LL Max Defl L / 360 LL Actual Defl L / 963
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Section (in') Shear (inz) TL Defl (in) LL Defl
49.91 32.38 0.13 0.10
45.14 13.67 0.40 0.27
OK OK OK OK
90°1° 42°!° 32% 37°I°
rd tpsil rv tpsq t tpsi x mn) rc! tpsil
Base Values 900 180 1.6 625
Base Ad'usted 1080 180 1.6 625
CF Size Factor 1.200
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 400 Uniform TL: 500 = A
Uniform Load A
0
R1 = 2031 R2 = 2031
SPAN = 8 FT
Uniform and partial uniform loads are Ibs per lineal ft.
V'~~ t
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 UPPER FLOOR FRAMING
g 1 Date: 6/14/08
Selection 5-1/8x 10-112 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions
Min Bearing Area R1= 4.7 inZ R2= 4.7 inZ DL Defl 0.22 in Suggested Camber 0.33 in
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span 16.5 ft Reaction 1 LL 2145 # Reaction 2 LL 2145 #
Beam Wt per ft 13.08 # Reaction 1 TL 3078 # Reaction 2 TL 3078 #
Bm W1 Included 216 # Maximum V 3078 #
Max Moment 12696 '# Max V (Reduced) 2751 # i
~ TL Max Defl L / 240 TL Actual Defl L / 277
'~ LL Max Defl L / 360 LL Actual Defl L / 398
Section (in') Shear (inz) TL Defl (in) LL Defl
94.17 53.81 0.72 0.50
55.20 14.95 0.83 0.55
OK OK OK OK
59% 28% 87% 90%
Values
Adjustments
Fb (psi) Fv (psi) E (psi x mil) rc! (psi)
Base Values 2400 240 1.8 650
Base Ad'usted 2760 276 1.8 650
Cv Volume 1.000
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Loads Urntorm LL: i tiu urnrorm i ~: ~uu = H
Par Unif LL Par Unif TL Start End
100 H = 160 0 16.5
H
Uniform Load A
0
R1 = 3078 R2 = 3078
SPAN = 16.5 F7
Uniform and partial uniform loads are Ibs per lineal ft.
u
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 UPPER FLOOR FRAMING
B2 Date: 6/14/08
Selection 6x 12 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2001
Min Bearing Area R1= 2.2 inZ R2= 2.2 inZ DL Defl 0.24 in
Data
Beam Span 20.0 ft Reaction 1 LL 750 # Reaction Z LL 750 #
Beam Wt per ft 15.37 # Reaction 1 TL 1354 # Reaction 2 TL 1354 #
Bm Wt Included 307 # Maximum V 1354 #
Max Moment 6768 '# Max V (Reduced) 1224 #
TL Max Defl L / 240 TL Actual Defl L ! 447
LL Max Defl L / 360 LL Actual Defl L / 807
Attributes
Actual
Critical
Status
Ratio
Vatues
Adiustments
Loads
Section (in') Shear (inZ) TL Defl (in) LL Defl
12123 63.25 0.54 0.30
80.72 9.39 1.00 0.67
OK OK OK OK
67% 15% 54% 45%
ro tpsil rv tpsil t tpsi x mul rc ~ tpsil
Base Values 875 170 1.3 625
Base Ad~usted 1006 196 1.3 625
CF Size Factor 1.000
Cd Duration 1.15 1.15
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 75 Uniform TL: 120 = A
Uniform Load A
R1 = 1354 R2 = 1354
SPAN = 20 FT
Uniform and partial uniform loads are Ibs per lineal ft.
~/ :. ~1 t
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 UPPER FLOOR FRAMING
B3 Date: 6/14/08
Selection 6-3/4x 13-112 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions
Min Bearing Area R1= 8.0 inz R2= 8.0 inz DL Defl 0.18 in Suggested Camber 0.26 in
Data
Beam Span 20.0 ft Reaction 1 LL 4000 # Reaction 2 LL 4000 #
Beam Wt per ft 22.14 # Reaction 1 TL 5221 # Reaction 2 TL 5221 #
Bm Wt Included 443 # Maximum V 5221 #
Max Moment 26107'# Max V (Reduced) 4634 # ',
TL Max Defl L / 240 TL Actual Defl L / 319
LL Max Defl L 1360 LL Actual Defl L / 416
Attributes
Actual
Critical
Status
Ratio
Values
Adiusfinents
Loads
Section (in') Shear (inz) TL Defl (in) LL Defl
205.03 91.13 0.75 0.58
135.11 28.96 1.00 0.67
OK OK OK OK
66% 32% 75% 87%
f-b (psq Fv (psi) E (psi x mil) Fc ~ (psi)
Base Values 2400 240 1.8 650
Base Ad~usted 2319 240 1.8 650
Cv Volume 0.966
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 400 Uniform TL: 500 = A
Uniform Load A
0 0
R1 = 5221 R2 = 5221
SPAN = 20 FT
Uniform and partial uniform loads are Ibs per lineal ft.
,~
~-
BeamChek v2005 Licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3072 UPPER FLOOR FRAMING
B4 Date: 6/15/08
Selection (2) 2x 10 HF #2 Lu = 0.0 Ft
Conditions NDS 2001
Min Bearing Area R1= 1.9 inZ R2= 1.9 in2 DL Defl 0.03 in
Data
Beam Span 10.0 ft Reaction 1 LL 600 # Reaction 2 LL 600 #
Beam Wt per ft 6.74 # Reaction 1 TL 784 # Reaction 2 TL 784 #
Bm Wt Included 67 # Maximum V 784 #
Max Moment 1959'# Max V (Reduced) 663 #
TL Max Defl L / 240 TL Actual Defl L / 877
LL Max Defl L / 360 LL Actual Defl L / >1000
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Section (in') Shear (in`) TL Defl (in) t_L Ueti
42.78 27.75 0.14 0.10
25.15 6.63 0.50 0.33
OK OK OK OK
59% 24% 27% 31%
Fb (psi) Fv (psi) t (psi x mu) rc ~ tpsi)
Base Values 850 150 1.3 405
Base Ad'usted 935 150 1.3 405
CF Size Factor 1.100
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress NIA
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 120 Uniform TL: 150 = A
Uniform Load A
0
R1 = 784 R2 = 784
SPAN = 10 FT
Uniform and partial uniform loads are Ibs per lineal ft.
~~~
BeamChek v20051icensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3072 UPPER FLOOR FRAMING
g5 Date: 6/15!08
Selection (2) 2x 10 HF #2 Lu = 0.0 Ft
Conditions NDS 2001
Min Bearing Area R1= 1.9 in2 R2= 1.4 in2 DL Defl 0.10 in
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span 9.5 ft Reaction 1 LL 190 # Reaction 2 LL 190 #
Beam Wt per ft 6.74 # Reaction 1 TL 765 # Reaction 2 TL 558 #
Bm Wt Included 64 # Maximum V 765 #
Max Moment 2331 '# Max V (Reduced) 721 #
TL Max Defl L / 240 TL Actual Defl L / 897
LL Max Defl L / 360 LL Actual Defl L / >1000
Section (in') Shear (ins) TL Defl (in) LL Defl
42.78 27.75 0.13 0.03
29.91 7.21 0.48 0.32
OK OK OK OK
70°l0 26% 27% 9%
Values
Adjustments
Fb (psi) Fv (psi) E (psi x mil) Fc ~ (psi)
Base Values 850 150 1.3 405
Base Ad~usted 935 150 1.3 405
CF Size Factor 1.100
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
C1 Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Loads Uniform LL: 4U Uniform I L 5U = A
Point TL Distance
B = 784 3.5
Uniform Load A
Pt loads:
0
R1 = 765 R2 = 558
SPAN = 9.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
~:-
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3072 UPPER FLOOR FRAMING
B6 Date: 6/15/08
Selection (2) 2x 10 HF #2 Lu = 0.0 Ft
Conditions NDS 2001
Min Bearing Area R1= 0.8 inZ R2= 0.8 in2 DL Defl <0.01 in.
Data
Beam Span 6.0 ft Reaction 1 LL 240 # Reaction 2 LL 240 #
Beam Wt per ft 6.74 # Reaction 1 TL 320 # Reaction 2 TL 320 #
Bm Wt Included 40 # Maximum V 320 #
Max Moment 480 '# Max V (Reduced) 238 #
TL Max Defl L ! 240 TL Actual Defl L / > 1000
LL Max Defl L / 360 LL Actual Defl L / >1000
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Section (in') Shear (in2) TL Defl (in) LL Defl
42.78 27.75 0.01 <0.01
6.16 2.38 0.30 0.20
OK OK OK OK
14% 9% 4% 5%
Fb (psi) Fv (psq t (psi x mu) rc! tpsil
Base Values 850 150 1.3 405
Base Ad~usted 935 150 1.3 405
CF Size Factor 1.100
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N!A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 80 Uniform TL: 100 = A
Uniform Load A
0 0
R1 = 320 R2 = 320
SPAN = 6 FT
Uniform and partial uniform loads are Ibs per lineal ft.
v-
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3072 UPPER FLOOR FRAMING
67 Date: 6!15/08
Selection 5-1/8x 9 GLB 24F-V4 DF/DF Lu = 0.0 Ft ~~
Conditions
Min Bearing Area R1= 4.6 inz R2= 4.6 inz DL Defl 0.06 in Suggested Camber 0.09 in
Data
Beam Span 10.5 ft Reaction 1 LL 2363 # Reaction 2 LL 2363 #
Beam Wt per ft 11.21 # Reaction 1 TL 3012 # Reaction 2 TL 3012 #
Bm Wt Included 118 # Maximum V 3012 #
Max Moment 7906'# Max V (Reduced) 2582 #
TL Max Defl L / 240 TL Actual Defl L / 451
~ LL Max Defl L / 360 LL Actual Defl L t 575
Attributes
Actual
Critical
Status
Ratio
Values
Adlustmenfs
Loads
Section (in') Shear (inz) TL Defl (in) LL Defl
69.19 46.13 0.28 0.22
39.53 16.14 0.53 0.35
OK OK OK OK
57°I° 35% 53% 63%
ro tpsi) rv tpsi/ t tpsi x mul rc ~ tpsi/
Base Values 2400 240 1.8 650
Base Ad'usted 2400 240 1.8 650
Cv Volume 1.000
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 450 Uniform TL: 563 = A
Uniform Load A
0
R1 =3012 R2=3012
SPAN = 10.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
U~:.~
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3072 UPPER FLOOR FRAMING
B7A Date: 6/15/08
Selection 5-1/4x 9-1/4 2.0E TJ Parallam E.S. PSL Lu = 0.0 Ft
Conditions
Min Bearing Area R1= 3.1 in2 R2= 4.9 in2 DL Defl 0.22 in
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span 14.0 ft Reaction 1 LL 1454 # Reaction 2 LL 2586 #
Beam Wt per ft 15.18 # Reaction 1 TL 2362 # Reaction 2 TL 3669 #
8m Wt Included 212 # Maximum V 3669 #
Max Moment 11659 '# Max V (Reduced) 3223 #
TL Max Defl L ! 240 TL Actual Defl L / 278
LL Max Defl L / 360 LL Actual Defl L / 439
Values
Adjustments
Section (in') Shear (in2} TL Defl (in) LL Defl
74.87 48.56 0.60 0.38
46.87 16.67 0.70 0.47
OK OK OK OK
63% 34% 86% 82%
f ti (psp t-v (psq t (psi x mu/ rc! tpsil
Base Values 2900 290 2.0 750
Base Ad~usted 2985 290 2.0 750
CF Size Factor 1.029
Cd Duration 1.Q0 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Loads
Point TL Distance Par Unif LL Par Unif TL Start End
B = 765 6.0 120 H = 150 0 6.0
310 1 = 388 6.0 8.0
450 J = 563 8.0 14.0
J
H
Pt loads:
R1 = 2362 R2 = 3669
SPAN = 14 FT
Uniform and partial uniform loads are Ibs per lineal ft.
I""'I
BeamChek v2005 licensed to: Welter Consulting Engineers, P C. Reg # 5234-65779
DONA /PLAN 3072 UPPER FLOOR FRAMING
gg Date: 6/15/08
Selection W 8x 24 36 ksi Wide Flange Steel Lateral Support at: Lc = 6.9 ft max.
Conditions Actual Size is 6-1/2 x 7-7/8 in.,
Min Bearing Length R1= 0.9 in. R2= 0.9 in. DL Defl 0.25 in Suggested Camber 0.38 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Beam Span 20.0 ft Reaction 1 LL 3600 # Reaction 2 LL 4000 #
Beam Wt per ft 24.0 # Reaction 1 TL 5019 # Reaction 2 TL 5519 #
Bm Wt Included 480 # Maximum V 5519 #
Max Moment 27740 '# Max V (Reduced) N!A
TL Max Defl L / 240 TL Actual Defl L ! 283
LL Max Defl L / 360 LL Actual Defl L / 402
Section (in') Shear (inz) TL Defl (in) LL Defl
20.90 1.94 0.85 0.60
14.01 0.38 1.00 0.67
OK OK OK OK
67% 20°Jo $5% 90%
Fb (psi) Fv (psi) E (psi x mil)
Base Value Fy
Base Ad'usted 36000
23760 36000 29.0
14400 29.0
YP Factor, Lc 0.66 0.40
At Point Loads: Provide these minimum bearing lengths in inches or provide web stiffeners.
B = 0.9
Loads
Point TL Distance Par Unif LL Par Unif TL Start End
B = 558 10.0 340 H = 425 0 10.0
420 I = 525 10.0 20.0
I
H
Pt loads:
0 0
R1 =5019 R2=5519
SPAN = 20 FT
Uniform and partial uniform loads are Ibs per lineal ft.
v~y
BeamChek v2005 licensed to: Weller Consulting Engineers, P_ C. Reg # 5234-65779
DONA /PLAN 3076 MAIN FLOOR FRAMING
TYPICAL JOIST Date: 6/14/08
Selection 2x 10 HF #2 @ 16 in. oc Lu = 0.0 Ft
Conditions Repetitive Use, NDS 2001
Min Bearing Area R1= 1.0 in2 R2= 1.0 in2 DL Defl 0.06 in
Data
Beam Span 12.5 ft Reaction 1 LL 333 # Reaction 2 LL 333 #
Beam Wt per ft 0 # Reaction 1 TL 417 # Reaction 2 TL 417 #
Bm Wt Included 0 # Maximum V 417 #
Max Moment 1302'# Max V (Reduced) 365 #
TL Max Defl L ! 240 TL Actual Defl L J 528
LL Max Defl L / 360 LL Actual Defl L ! 660
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Section (in') Shear (in2) TL Defl (in) LL Defl
21.39 13.88 0.28 0.23
14.53 3.65 0.63 0.42
OK OK OK OK
68% 26% 45% 55%
rn (psi) rv (psi) t (psi x mu) rc! (psq
Base Values 850 150 1.3 405
Base Ad~usted 1075 150 1.3 405
CF Size Factor 1.100
Cd Duration 1.00 1.00
Cr Repetitive 1.15
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform LL: 53 Uniform TL: 67 = A
Uniform Load A
0 0
R1 =417 R2=417
SPAN = 12.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
a
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3076 MAIN FLOOR FRAMING
TYPICAL BEAM Date: 6/14/08
Selection 4x 10 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2001
Min Bearing Area R1= 4.2 inZ R2= 4.2 inZ DL Defl <0.01 in.
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span 5.0 ft Reaction 1 LL 2100 # Reaction 2 LL 2100 #
Beam Wt per ft 7.87 # Reaction 1 TL 2645 # Reaction 2 TL 2645 #
Bm Wt Included 39 # Maximum V 2645 #
i Max Moment 3306'# Max V (Reduced) 1829 #
TL Max Defl L ! 240 TL Actual Defl L / >1000
LL Max Defl L / 360 LL Actual Defl L / > 1000
Section (in') Shear (inZ) TL Defl (in) LL Defl
49.91 32.38 0.04 0.03
36.73 15.24 0.25 0.17
OK OK OK OK
74% 47% 16% 19%
Values
Adjustments
Loads
Fb (psi) --v (psp t (psi x mn) rc ~ tpsil
Base Values 900 180 1.6 625
Base Ad'usted 1080 180 1.6 625
CF Size Factor 1.200
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Unifiorm LL: 840 Uniform TL: 1050 = A
Uniform Load A
0 0
R 1 = 2645 R2 = 2645
SPAN = 5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
vim.
BeamChek v2005 licensed to: Weller Consulting Engineers, P. C. Reg # 5234-65779
DONA /PLAN 3072 MAIN FLOOR FRAMING
TYPICAL BEAM Date: 6/16/08
Selection 4x 10 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2001
Min Bearing Area R1= 3.8 in2 R2= 3.1 in2 DL Defl 0.03 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Beam Span 5.0 ft Reaction 1 LL 775 # Reaction 2 LL 775 #
Beam Wt per ft 7.87 # Reaction 1 TL 2406 # Reaction 2 TL 1933 #
Bm Wt Included 39 # Maximum V 2406 #
Max Moment 4021 '# Max V (Reduced) 2101 #
TL Max Defl L / 240 TL Actual Defl L / >1000
LL Max Defl L / 360 LL Actual Defl L / >1000
Section (n') Shear (inz) TL Defl (in) LL Defl
49.91 32.38 0.04 0.01
44.68 17.51 0.25 0.17
OK OK OK OK
90% 54% 17% 7%
r4 tpsil rv tpsi) t (psi x mn) rc i (psq
Base Values 900 180 1.6 625
Base Ad usted 1080 180 1.6 625
CF Size Factor 1.200
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0 0
Loads Uniform LL: 310 Uniform TL: 388 = A
Point TL Distance
B = 2362 2.0
Uniform Load A
Pt loads:
R1 = 2406 R2 = 1933
SPAN = 5 FT
Uniform and partial uniform loads are Ibs per lineal ft.