Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-0058 Planning Guide 043008
Page 1 of 1 John Rowland From: Duane Bishop [duane.bishop@nwlifts.com] Sent: Wednesday, April 30, 2008 4:16 PM To: John Rowland Subject: Elevator info from Duane Bishop as requested Attachments: Eclipse planning guide-2007.pdf Hello John, Here is a copy of the planning guide for the elevator that we discussed. Please look this over and feel free to call me if you have any questions Thanks, Duane Bishop Nationwide Lifts LLC P.O.Box1643 Gig Harbor, WA 98335 253.514.9722 Office/Cell 253.851.2215 Fax Nationwide Lifts .. .. _. •, ;ender •c. t-crne elevators. No virus found in this outgoing message. Checked by AVG. Version: 7.5.524 /Virus Database: 269.23.6/1407 -Release Date: 4/30/2008 11:35 AM 4/30/2008 ~~~SAVARIA D CONCORD Your Accessibility Partners ECLIPSE RESIDENTIAL ELEVATOR Planning Guide Applicable Codes: ASME A17.1/CSA-B44 Safety Code for Elevators and Escalators Section 5.3-Private Residential Elevators December 3, 2007 Part No.000623 t~ FILE Copyright ©2007- Savaria Concord, All Rights Reserved Purpose of this guide This guide assists architects, contractors, and lift professionals to incorporate the Eclipse Residential Elevator into a residential building design. The design and manufacture of the Eclipse Residential Elevator meets the requirements of the ASME A17.1/CSA-B44-Safety Code for Elevators and Escalators-specifically Section 5.3-Private Residence Elevators. We recommend that you contact your local authority having jurisdiction to ensure that you adhere to all local rules and regulations pertaining to residential elevators. How to use this guide 1 Determine your client's intended use of the lift. 2 Determine the local code requirements. 3 Determine the site installation parameters. 4 In this guide, determine the car type and hoistway size requirements. 5 In this guide, plan for electrical requirements. Eclipse Planning Guide 03-M12-2007 Table 1-0: Eclipse specifications (meets ASME A17.1 Part V Section 5.3 residential elevator requirements) Specification type Specification data Load capacity 750 lbs. (340 kg), 950 lbs. (431 kg),1000 lbs. (454 kg) Rated speed 40 fpm (0.20 mps) standard. Power supply 208 volt - 230 volt, single phase, 60 Hz, 20 amps (circuit supplied by others) Lighting supply 120 volt, 60 cycle, 15 amps (circuit supplied by others) Drive system Automatic 2HP-geared roller chain variable frequency drive, complete with counterweight Temperature operating range - 10 C to + 40 C / 14 O Cab size • W36" x L48" x H80" (914 mm x 1219 mm x 2032 mm), Type 1, 2, 3, 4, 5 • W36" x L54" x H80" (914 mm x 1371 mm x 2032 mm), Type 1, 2, 3, 4, 5 • W36" x L60" x H80" (914 mm x 1524 mm x 2032 mm), Type 1, 2, 3, 4, 5 • W40" x L54" x H80" (1067mm x 1371 mm x2032 mm), Type 1, 2, 3, 4, 5 Cab panel and finish Solid melamine or MDF Panels (standard), unfinished Oak veneer panels (optional), finished recessed veneer panels (optional), solid hardwood raised panels (optional) Maximum travel 50 feet (12.24 m) - 60 feet (18.29 m) available where code permits Control system Relay logic controller complete with diagnostic LEDs Levels and openings Up to 4 stops / up to 2 cab openings Pit depth requirement 6" (152 mm) minimum up to 96" (2845 mm) / 11" (279 mm) minimum with buffer springs Minimum overhead clearance 96" (2438 mm) for standard 80" cab, 114" (2896 mm) for 96" cab Hall station and control panel finish • clear or bronze anodized aluminum (standard) or stainless steel (optional) or brass (optional) • rectangular (standard) or oval (optional) hall stations, keyless (standard) or keyed (optional) Standard features • automatic cab on/off lighting • recessed gate pocket • digital display in car operating panel • clear or bronze anodized aluminum cab entrance trim and handrail • data plates, capacity tags • proximity floor selection, stopping and two-way levelling • motor access cover (locked and switched) • home landing feature • presentation drawings • modular rail sections • unfinished plywood sub-floor • white ceiling with four incandescent pot lights • melamine cab with six different color choices Safety features • cab gate safety switch • pit run/stop switch and car top run/stop switch • emergency stop and alarm buttons • uninterruptible power supply (UPS)/battery back-up system for lowering, automatic gate operation (if equipped), and electrical interlock operation and lighting in the event of a power failure. • upper and lower terminal limits • final limit switch • mechanical rail shoring blocks • sling: factory pre-assembled speedy sling c/w pre-set slack chain safety brake and switch. Options • 96" high cab • rated speed - (50 fpm (0.250 mps) available where code permits) • accordion car gate (choice of style) • stainless steel trim pack • brass trim pack • automatic gate operator (accordion gates only) • automatic swing landing door operator • buffer springs (11" pit depth minimum) • laminate flooring in finished Oak, Maple, or Cherry • finished oak hardwood flooring • interlocks for doors by others (Kwiklock or EMI) • keyed oNoff control panel and hall stations • cab interior in unfinished Oak, Birch, Cherry, or Maple veneer • recessed cab panels in Cherry, Oak, or Maple veneer • raised cab panels in solid Cherry, Oak, or Maple veneer • telephone cabinet to match trim • custom cab size Eclipse Planning Guide 03-M12-2007 Eclipse cab types Table 1-1: Type 1 left hand sizes 36 x 48 502 55 31** 294 36 36 x 54 502 61 33 294 36 36 x 60 502 67 36 294 36 40 x 54 542 61 33 334 36 * Note: * 36" at gate and 40" at cab Note: ** 30" if right hand motor Note: All measurements in Inches (~~). Table 1-2: Type 1 right hand sizes 36 x 48 502 55 31 ** 294 36 36 x 54 50 2 61 33 29 4 36 36 x 60 502 67 36 294 36 40 x 54 542 61 33 334 36 Note: * 36" at gate and 40" at cab Note: ** 30" if left hand motor Figure 1-4: Type 3 Table 1-3: Type 2 36 x 48 502 552 27a 2°~ 36 36 x 48 528 55 31** 28 6-34'a *348-36 36 x 54 50 2 612 30 a 29 4 36 36 x 54 52 8 61 33 2818 -40 4 *34 8 -36 36 x 60 502 672 334 294 36 36 x 60 528 67 36 28 s -464 `348 -36 40 x 54 54'- z 61'- z 303 a 33'- 36' a 40 x 54 568 61 33 318- 404 36 - 36 * Note: * 36" at gate and 40" at cab Note: * C side clear opening Note: ** 30" if left hand motor Eclipse Planning Guide 03-M12-2007 Figure 1-2: Type 1 right hand Figure 1-1: Type 1 left hand Table 1-4: Type 3 Figure 1-3: Type 2 Figure 1-5: Type 4 C of 36 x 48 528 55 31 ** 28 6 -344 *346 -36 36 x 54 528 61 33 28 e -404 *348 -36 36 x 60 52'-8 67 36 28 a -464 *348 -36 40 x 54 56 8 61 33 318 -40 4 36 - 36 Note: * A side clear ope ning Note: ** 30" if right han d motor Table 1-7: Type 5: left hand Table 1-6: Type 5 center 36 x 48 528 564 288 286 * 36 36 x 54 528 624 318 318 36 36 x 60 528 684 348 348 * 36 40 x 54 568 624 318 318 * 36 Note: * For gate stacked opposite use same dimensions but from Side A (mirror in~nge) Table 1-8: Type 5: right hand 36 x 48 528 55 272 334 36 36 x 48 528 55 272 334 36 36 x 54 528 61 302 394 36 36 x 54 528 61 302 394 36 36 x 60 52'-8 67 332 454 36 36 x 60 528 67 332 454 36 40 x 54 568 61 302 394 36 40 x 54 568 61 302 394 36 Eclipse Planning Guide 03-M12-2007 Table 1-5: Type 4 Figure 1-6: Type 5 center Figure 1-7: Type 5 left hand Figure 1-8: Type 5 right hand Figure 1-9: Eclipse hoistway with rail Hoistway type 1 right hand with rail Overhead from of top landing point of top of - 96"for 80"ca - 114"for 96"c 1 floor o lowest _~ hoistway b Hah call ~ ~ Landing ~ door To p Floor landin Total traveT~ Landing C Hall ~ call ~ door 88 88 o°Oo Bottom Floor landing Pit t a Motor « x ~ access door lotor Rail Brackets Modular rail system ounterweight ;ontroller Rails Eclipse Planning Guide 03-M12-2007 Figure 1-10: Eclipse hoistway mount Overhead 96" for 80" cab height or 114" for 96" cab height One 1/2" piece of plywood between the two 2" x 10" ~ Maximum vertic~ distance without additional suppo Eclipse mount Each vertical support stack requires: - two 2" x 1Q" , One 2" x 4" centre of st Maximum verticz distance without additional SUppO Pit two2"xd"on each stack Note: See Figure 1-11 for Eclipse mount overhead visible views General Contractor landing door J Finish door jam to inside clear General Contractor landing door J 12" Finish door jam to inside clear Pit -minimum depth 6" Eclipse Planning Guide 03-M12-2007 Figure 1-11: Eclipse top of hoistway view for wood construction ® ~ 0 v v o--o O ~ n ~ -~ n A m ~ ~ o o ~ ( D -~ ~ N N ~ m ~ ~ O ~ N tJ X X ~' n ~ N N N O ~ - O N ~ "~ X d I Y ni A ~ vL.I~IYIl--.- ~_ ~ ~_ N (n ~_ 2 G~ v O O 6 N ~~ d C (D Q 0 m -~. 0 c V J "S n r+ _~ S~• G 0 rn c~ .~ O v ® ®~ °~ N -n n O ~ O ~ x O O ~' fD O r~ -. A . ~p ~ tV rD f1 ~ N ~ X ~ O a X ,-. .p - 7 to ~ ? C ~ O .+ O~ Eclipse Planning Guide 03-M 12-2007 Figure 1-12: Wall configuration for wood construction (continued) (~ m p~ (n ~ o m - ~ ~ • • ~ ~, ~ o ~ o -' N7 ~ ~,Ntn(~ N =~ t ., m Q - ~, c ~ N N <D ~X ~~ O N N ~'~ S ~~O ~ LU X .3+N ~D~mQ°~~c :~ uSi'~~ ~ "'•v~i o co ~wm ~ N~ Q Q°~.OX`r C p~0 -O ~~a I"~f ^~ J P'~` ^~ ~.1J m ~ -a' CD ~ ~ m ~ ~ o ~, ~ O o ~ a~ a ~ m < v ~ ~• ,-+ ~ O ~ ~ v ~ - ~ n O ,-+ ~~ C CD Q Eclipse Planning Guide 03-M12-2007 gv~ ~~~ m n3 m '~ _ 7~ ~_ ~ ~ (D q' (D ~ mv~a a m 1 9 Safety first-3 & 5 rule The ASME A17.1/CSA-B44-Safety Code for Elevators and Escalators mandates the following maximum Hoistway door clearances: • clearance between the hoistway side of the landing door and the edge of the landing sill shall not exceed 3 in. (76 mm) • distance between the hoistway face of the landing door or gate and the car door or gate shall not exceed 5 in. (127 mm) • Eclipse Residential Elevator design is with a 1 inch running clearance and a 1 inch gate set back on the car; thus the hoistway doors must maintain a maximum set back of 3 inches. Note: Concrete block/masonry shafts and some commercial metal door frames often create 3 & 5 rule violations. Figure 1-13:3 & 5 rule Eclipse Planning Guide 03-M12-2007 10 ~ ~ "_' Y v O ~ ~- C Z C ~ c U N U X N H Q ~~ ~ Q N Y 0 o X Y° o X Y ~' Q d i "~ L ~ ~ O f•- •--• E U ~ l- ~ U !` ~ C ~ -p Q L ~ ~ ~ Q LO ~ V Q N Y U~ ~ ~ V O; C ~ N ++ ~~-+ N ~ ` ~ ~ L Nom,, C ~ ~ O ~ O~~ V ~• ~ O~ ~ O 3 'O N to .~ 0 ~~ ~ ~ ~ ~~Q3Q ~ •N~~~ Q ~ U t'..o ~~ ~ oQ O ~ E CCi oQ o ~ E ~~ ~ O (~ NM ~' O ~ = NM ~+O ~ O ~ Q L. 00 0 0 0 +-~ 00 O f6 O U ~ W ° d• ° N ~ ~ •~ N ONN~ C~ U NN~~ r _N ~ ~ ON C N ~ ~ v +• c~ N Q .- ~ ~ ~ ~ ? ~ N O ~ ~ ~ NU '/^~ ~ '~ ~ O N O to VJ ~ ~ ~ •~ (~ N (~ ~ L ~ X ~ L ~ m ~ ~ ~ v ~ ~ ~ ~ ~ ~Q ~ ~ Q~ ~ •~ ~ ~ Q ~ ~ m~ ~n ~ ~ Y (~ o ~ - E Y ~ cfl ~ ~ M Q N U J Q~ U~ ~ •i ~ N ~ ~ ~ W ~ ~ U ~ _ ~ ~ L ~~~ C ~, N Q `O C +'. X 0 0 •L >> ~. ~ Y o °N ~ o Y o N ~ }, 00 O ~ cn ~ ~ ON r ~ ~ O ~'O C ~ O >+ ~ C ~ .-~ ~ N L~ N O ~~~ N O ~ r r r N ~ (6 .~ ~ N N N ~- O L "a Q- O v~ >-000 ~3N°'~ ~'3~ o ~ •~ Q ~ O ~ '~ Q. C ~ w Q O a 0~ ~ C C'7 O O ~ Q Q~ N ~ ~' O Q ~ N M~ Y In L i i ~~~ ~ i i to ~ ~ ~ ~ ~ L ~ > ~ ~ ~ ~ ~ > O ~ 00 O O _ O ~ N N v C O ~ N N O C O ~ ~ ~ Eclipse Planning Guide 03-M12-2007 11 i-+ ~--~ L Q~ L ~--~ U L d~ .~^ 1.i ^~~ 'W^ V/ U L ~--i U N N Q~ !/~ U W ~Uo ~ Q N C ~ ~ .~ V ~ ~ ~ ~NXN.~ C ~ ~. C Q ~ ~~.~0 Q ~ln._N C LL ~ ~ ~ N J, U C N N L W _~ ~L a-+ .~ c 0 U a U W Eclipse Planning Guide 03-M12-2007 12 Eclipse Residential Elevator Specification PART 1 -GENERAL 1.01 SCOPE The product described herein, manufactured by Savaria Concord Lifts Inc., is a private residence home elevator designed and dimensioned to provide access to all levels of the home based on the individual's requirements. 1.02 References The Residential Elevator shall be designed and manufactured and installed in accordance with the following standards: 1. American Society of Mechanical Engineers (ASME)/Canadian Standards Association (CSA) 2. American National Standards Institute (ANSI) 3. National Electrical Code (NFPA 70)/Canadian Electrical Code 4. International Building Code (IBC)/Canadian Building Code (CBC) 5. Americans with Disabilities Act Architectural Guidelines (ADAAG) -where applicable 6. Local Codes and Regulations as applicable 1.03 System Description A: Drive System: Automatic 2 HP -Geared Roller Chain Variable Frequency Drive complete with counterweight, Relay Logic Controller and Diagnostic LEDs. B: Number of Stops: (specify) Two to Four C: Car Configuration: (specify) On/Off Same Side, Walk through, or 90 degree entry D: Maximum Travel: (specify) 50 feet (Up to 60 feet -where permitted) E: Rated Load: (specify) 750 Ibs or 1000 Ibs F: Rated Speed: (specify) 40 fpm - 50 fpm option available where permitted G: Car Size: 1. (specify): 36 x 48, 36 x54, 36 x 60, 40 x 54 or custom 2. (specify): 80" or 96" high ceiling H: Car Walls: specify) Solid Melamine or MDF Panels (Standard), Unfinished Oak Veneer Panels (optional), Finished Recessed Veneer Panels (Optional), Solid Hardwood Raised Panels (optional) I; Car Entrance Trim: (specify) Clear anodized aluminum or bronze anodized aluminum J: Car Ceiling: (specify) White or Wood Veneer to match wall panels K: Car Lighting: Four Recessed Incandescent Down Lights (specify) stainless steel or brass L: Handrail: (specify) Clear anodized aluminum, Bronze anodized aluminum, Stainless Steel or Brass M: Operating Features: 1. Car Operating Panel: (specify) Clear anodized aluminum, Bronze anodized aluminum, Stainless Steel or Brass panel with illuminated automatic controls, emergency stop switch, alarm button and car position and direction indicator and key lock. 2. Hall Stations: (specify) Clear anodized aluminum, Bronze anodized aluminum, Stainless Steel or Brass panel with illuminated automatic button (specify option) rectangular or oval design. 3. Pit Switch and Car top run/stop switch 4. Uninterruptible power supply (UPS)/Battery Back-up system for lowering, automatic gate operation (if equipped), and electrical interlock operation and lighting in the event of a power failure. 5. Automatic homing option to (specify) floor available. 6. Telephone Cabinet: (specify) Clear anodized aluminum, Bronze anodized aluminum, Stainless steel or Brass 7. Car Gate(s): (specify) Accordion folding gate with offset safety hinge and safety switch (specify style) Panelfold (clear anodized aluminum or bronze anodized aluminum with 3 clear acrylic inserts), Clearfold (clear anodized aluminum with clear acrylic inserts) or Visifold (bronze anodized aluminum with bronze acrylic inserts) or Black Scissor Gate complete with safety switch 8. Hoistway Door Interlocks: (specify) Electromechanical interlocks (Kwiklock or EMI) 9. Upper and Lower terminal limits 10. Final limits 11. Slack Chain safety with manual reset switch 12. Two-way leveling 13. Trip timer motor protection system 14. (specify option) Automatic accordion style gate operator(s) 15. (specify option) Automatic swing style landing door operator 16. (specify option) Hardwood cab flooring (specify) cherry, maple, or oak 17. (specify option) Buffer springs (requires 12" pit). 1.04 Quality Assurance A. Manufacturer: Provide elevator manufactured by a firm with a minimum of 20 years experience in fabrication of elevators equivalent to those specified. B. All designs, clearances, workmanship and material, unless specifically accepted, shall be in accordance with all codes having legal jurisdiction. C. All load ratings and safety factors shall meet or exceed those specified by all governing agencies with jurisdiction and shall be certified by a professional engineer. D. Elevator shall be subject to applicable state, local and city approval prior to installation and subject to inspection after installation. Determination of and adherence to these regulations is the responsibility of the elevator contractor. E. Welders certified in accordance with the (AWS D1.1/CWB 47.1) requirements shall perform all welding of all parts. F. Substitution: No Substitutions permitted 1.05 Warranty A. Savaria Concord Limited Warranty: Manufacturer shall warrant component parts of the Eclipse Residential Elevator for a period of 3 years from shipment from the manufacturing facility. 1.06 Maintenance A. The Eclipse Residential Elevator must be maintained in accordance with manufacturer's instructions. Part 2 Product 2.01 Manufacturer A. Provide the Eclipse Residential Elevator with variable frequency drive manufactured by Savaria Concord Lifts Inc. 1. Contact 107 Alfred Kuehne Blvd. Brampton, Ontario, Canada; Telephone: 1-800-661-5112; Fax: 1-905-791-2222; e-mail: info~concordelevator.com web site: www.savariaconcord.com 2.02 Material A. Guide Rail: Modular Guide Rail assembly incorporating 6 Ib machined elevator T" Rails B. Chain: 2 only #60 roller chains C. Sling: Factory pre-assembled speedy sling c/w pre-set slack chain safety brake D. Platform Floor: Unfinished recessed plywood flooring 2.03 Finishes A. Components shall be prepared with a 3 stage cleaning process and finished with an electrostatically applied baked polyster Concord White gloss powder. 2.04 Electrical Systems A. The electrical contractors shall provide: 1. 230 V AC, 20 Amp, 60 Hz, single phase disconnect complete with auxiliary disconnect, neutral and ground (4 wires) in the controller area. 2. 120 V AC, 20 Amp, 60 Hz, single phase disconnect in the controller area for the car lights. 3. Telephone circuit in the controller area. Eclipse Planning Guide 03-M12-2007 13 Part 3 Execution 3.01 Acceptable Installers A. Installers shall be experienced in performing work of this section who have specialized in work comparable to that required for this project. B. Installers shall be certified and trained by the manufacturer. 3.02 Examination A. Use field dimensions and approved manufacturer's shop drawings to examine substrates, supports and other conditions under which this work is performed. Do not proceed with work until unsatisfactory conditions are corrected. 3.03 Installation A. The Eclipse Residential elevator shall be installed in accordance with manufacturer's instructions and as specified and approved by architect. B. Hoistway doors shall be installed by others. 3.04 Demonstration A. The elevator contractor shall make a final check of the elevator's operation in accordance with the instruction outlined in the Installation and Maintenance Manual with the Owner or Owner's representative present prior to turning the elevator over for use. The elevator contractor shall determine that operating and safety devices are functioning properly. Note 1: It is the intent of this specification to broadly outline the equipment required. This specification does not cover the details of the design and construction. Note 2: Dimensions and specifications are subject to constant change and continually evolving codes and product applications. For additional technical information, contact Savaria Concord Lifts at 1-800-661-5112 or www.savariaconcord.com. Important notice This Planning guide provides nominal dimensions and specifications useful for the initial planning of a lift project. Dimensions and specifications are subject to constant change and continually evolving code and production applications. Before beginning actual construction of the hoistway, please consult Savaria Concord Lifts [nc. or the authorized Savaria Concord dealer in your area to ensure you receive site specific application drawings with the specifications and dimensions for your project. Visit our website for the most recent Eclipse drawings and dimensions. ~nd- Eclipse Planning Guide 03-M12-2007 Bavaria Concord Lifts Inc. Eclipse Planning Guide Copyright ©2007 -Bavaria Concord, All Rights Reserved Part No. 000623 03-M12-2007 Printed in Canada C]~C~SAVARIA D C~CONCORD Your Accessibility Partners