Loading...
McCammant FourplexesIPM.Note McCammant Fourplexes Roberta Allen Steve Harrington Roberta Allen EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=STEVEH McCammant Fourplexes EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_ALLEN EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_ALLEN Steve Harrington EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=STEVEH Jim Gibson Roberta Allen McCammant Fourplexes Roberta: Here are my comments for the McCammant Fourplexes. Item # 4 Water: 1. Please show sizing criteria to show how a 1 ½” to 2” fire line is going to be adequate for a fire sprinkler system for these units. Please include fire protection system drawings. 2. Please provide info showing the 2 - 2” water meters are going to be Master Meters or if they will have meters for each unit. If these are going to be Master Meters, they will also be required to have double check valve assemblies installed behind the meters. Item # 10 Sewer: 1. Please revise sewer connection note on sheet 1 of 5 on the drawing referring “SEE DETAIL # 7- ? This will need to show the complete number of the detail being called out. Item # 11 Sewer: 1. The location of the step sewer Carson Boxes must be shown on plans. Item # 18 Storm Treatment: 1. The Bay Saver Separation Storm Treatment Device, currently is not approved for use in the City of Yelm. Please look at other storm treatment devices such as AquaShield (AquaSwirl) which are currently approved for use in the City of Yelm. Please size your storm treatment adequately for the size of your project. Item # 20 Storm Treatment: 1. Please show infiltration gallery plan and profile for paved parking area, be sure to size accordingly for intended use to handle parking, drainage and other run off. Item # 24 Storm Treatment: 1. Please see City of Yelm Standard 7-20 for Typical End of Line Clean Out. Item # 26 Storm Treatment: 1. We have not received any revised plans for Landscape. Item # 29 Storm Treatment: 1. Plans need to show the location of the Fire Department Connection (FDC). Also needed are the criteria showing that the fire protection system is adequate for these buildings. All Sheets: Please revise title box on all sheets to read the proper title for what is being show on that plan sheet. <DC90029353CCCD468AA2A2858FFCD8F5329E44@server1.ci.yelm.wa.us> McCammant Fourplexes.EML Roberta Allen Roberta Allen 11.0 Roberta Allen EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_allen r_allen@ci.yelm.wa.us r_allen 458-3835 Community Development Roberta Allen Roberta Allen r_allen Jim Gibson EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Gibson jimg@ci.yelm.wa.us jimg 458-8438 Community Development Jim Gibson Jim Gibson Gibson