Loading...
20090003 Permit Pkg 011209fry r~fr~i71r7~ Selfr~li~Jir~li~J r~(r~lr~lr~ir~ (f71~ I~ r~ I~ I~i~l CITY OF YELM -BUILDING DEPARTMENT RESIDENTIAL CERTIFICATE OF OCCUPANCY Building Address Owner Name Owner Address Building Permit Number BLD-09-0003-YL Plan Number Plan Cottage# 1, Lot 36 Areas Special Building Official: G. Carlson Date: June 10, 2009 This structure is incompliance with the International Residential Code (Chapter 51-51 WAC) as adopted by the Washington State Building Code Council pursuant to Chapters 19.27 and 70.92 RCW, effective July 1, 2004 f~pF TtrFpA~ City of Yelm c~ 7 a 07 City: Auburn ~ Community Development Department Building Division Phone: (380)458-84 YELM Fax: (360) 458-3144 Applicant: Name: Triance Homes Address: 12639 SE 307th St. Prooerty Information: Site Address: 10130 Terra Glenn St. SE Assessor Parcel No. 81780003800 Name: Triance Homes Address: 4200 6th Ave SE # 301 Contractor License No: TRAN6194800 Project Information: Project: Vintage Greens, Plan Cottage #1 Description of Work: SFR, lot 36, Plan Cottage #1 Sq. Ft. per floor: (1st) 1208 (2nd) 0 Heat Type (Electric, Gas, Other): GAS Fees: Item Item Fee Building Permit 100-SOOk 1,178.96 Building Plan Review 11.19 Mechanical Permit 71.75 Plumbing Permit 90.00 Sewer Inspection 145.00 Water ERU 1,500.00 Water Meter (SFD) 300.00 State Building Fee 4.50 Fire District Impact Fee 534.08 Sewer ERU 6,050.00 Traffic Facilities Charge 1,334.21 TOTAL FEES: $11,219.69 Subdivision: Vintage Greens Permit No: BLD-09-0003-YL Issue Date: 01/12/2009 (Wo rk must be started within 180 days) Receipt No: 57921 Phone: 206-618-0483 State: WA Zip 98092 Lot: 36 Phone: 360-493-6002 State: WA Zip: 98503 Business License: 2940 Garage 461 Basement 0 Contact: Lee, Dan City: Lacey Expires: 0310310883 (3rd) 0 Unit Rate No. Units Unit Desc 5.6000 33.0730 $1,000 0.0000 0.0000 0.0000 0.0000 7.0000 10.0000 Fixture 145.0000 1.0000 ERU 1,500.0000 1.0000 ERU 0.0000 0.0000 0.0000 0.0000 0.3200 1,669.0000 square foot 6,050.0000 1.0000 ERU 1,321.0000 1.0100 Peak PM Trip SCANNED o t Zoe Base Amt Unit Fee 993.75 185.21 0.00 0.00 0.00 0.00 20.00 70.00 0.00 145.00 0.00 1,500.00 300.00 0.00 4.50 0.00 0.00 534.08 0.00 6,050.00 0.00 1,334.21 Applicant's Affadavit: OFFICIAL USE ONLY I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of # Sets of Prints: Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I futher certify that I am currently registered in the State of Washington. i Final Inspection: Date Date: ~ /O Firm ~OFTHFp~~ City of Yelm Permit Fees Schedule ~~ ~ Community Development Department Permit No: BLD-09-0003-YL Building Division Phone: (360) 458-8407 E L Fax: (360)458-3144 Applicant: Name: Triance Homes Phone: 206-618-0483 Address: 12639 SE 307th St. City: Auburn State: WA Zip 98092 Project Information: Project: Vintage Greens, Plan Cottage #1 Description of Work: SFR, lot 36, Plan Cottage #1 Site Address: 10130 Terra Glenn St. SE Assessor Parcel No. 81780003600 Fees: Item Acct Code Item Fee Base Amt Unit Fee Unit Rate No. Units Unit Desc Building Permit 100-500k 032 001-322-10-00 1,178 96 993.75 185.21 5.6000 33.0730 $1,000 Building Plan Review 100 001-345-83-00 11.19 0.00 0.00 0.0000 0.0000 Mechanical Permit 032 001-322-10-00 71.75 0.00 0.00 0.0000 0.0000 Plumbing Permit 032 001-322-10-00 90.00 20.00 70.00 7.0000 10.0000 Fixture Sewer Inspection 805 412-343-80-00 145.00 0.00 145.00 145.0000 1.0000 ERU Water ERU 715401-343-80-02 1,500.00 0.00 1,500.00 1,500.0000 1.0000 ERU Water Meter (SFD) 712 401-343-80-01 300.00 300.00 0.00 0.0000 0.0000 State Building Fee 160 001-386-00-00 4.50 4.50 0.00 0.0000 0.0000 Fire District Impact Fee 105 001-345-85-00 534.08 0.00 534.08 0.3200 1 ,669.0000 square foot Sewer ERU 802 412-343-50-01 6,050.00 0.00 6,050.00 6,050.0000 1.0000 ERU Traffic Facilities Charge 420 120-345-85-00 1,334.21 0.00 1,334.21 1,321.0000 1.0100 Peak PM Trip TOTAL FEES: $11,219.69 105 Yelm Ave. W. Yelm, WA 98597 RECEIPT No. 5 360-458-3244 RECEIVED ****ELEVEN THOUSAND TWO HUNDRED NINETEEN DOLLARS & 69 CENTS RECEIVED FROM DATE REC. NO. AMOUNT REF. NO. TRIANCE HOMES 01/12/09 57921 11.219.69 CHECK 12215 18741 NUTMEG ST SW ROCHESTER WA 98579 BUDGETARY BLD-09-0003-YL CITY OF YELM 2RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: ~L'~J G ~C~X1~ ~7~E~Z; t~ ~T~ ~ Parcel #: g ~ 7~C~036 OO Subdivision: I~/NTA~~ ~~~~"fN5 Lot #: 3'6 Zoning; ~ 4 New Construction ! Re-Model / Re-Roof /Addition Home Occupation Sign i i Plumbing i Mechanical Mobile /Manufactured Home Placement// ~ Other Project Descripti /Scope of Work: ~ S~O~eY ~~l~ED Z~A7 /~ (~/fg~ ~ ) Project Value: ~ZZdi OD O Building Area (sq. ft) 1S` Floor Jl~~ 2"d Floor Garage '~ ~ Deck Basement Carport Patio # Bedrooms ~ # Bathrooms t Heating: GASJOTHER or ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? ~ o If yes, a completed environmental checklist must accompany permit application. BUILDING OWNER NAME: T~IgN(_t:' c~2~;~P ADDRESS 4-Zi~~' ~~~ .l~C '~E -3~t' EMAIL CITY L/Ct `1 STATE ~--~~~ ZIP C'~~' ~~ TELEPHONE 0 93--EGO2 GENERAL CONTRACTOR %+UR/tt~~ t i~PUI>A TELEPHONE .~`E ate' . ADDRESS d7UC ~'t r+ H ~e 5~ ~ 30l EMAIL CITY ~1(e`1 STATE UJ.9 ZIP `18;0 FAX arc •-2476 CONTRACTOR'S LICENSE # T~IA~te`i J %~~GG EXP DAT .'CITY LICENSE # PLUMBING CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # ~~>;~ GF~.T:_ C;I~~'~` ;. ~==NEE #- MECHANICAL CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE_ ZIP FAX CONTF:A~'TOR~;~~ Li;,~~.~NSE ~' EXP DATE CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. Applicant's Signature Date Owner /Contractor /Owner's Agent /Contractor's Agent (Please circle one.) All permits are non-transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days 105 3'elm Ac~enue W'esf. PO Bo1 479 Yelm, 4i~A 9859? (360) 45b-3149 FAQ u~u•w.ci;velm.u!a.u~==~ ~ I THURSTON COUNTY DEVELOPMENT SERVICES 2006 WSEC PRESCRIPTIVE COMPLIANCE FORM ~._ I':, _ ::: _ ~nrt~srniN cxxttvn ~~ ~~ APPLICANT NAME: ( ~ (~ ~U CF t7 ~U iJ r - PROJECT ADDRESS: 1 ~ ~ / b TE2,e~ ~ L~ N/~/ ST 5~ HEATING SYSTEM TYPE (Check one): ~ Forced Air Furnace ^ Zone Heat ^ Other: MAXIMUM HEATING SYSTEM SIZE (BTU/Hr): 256 99 ~ yg MECHANICAL VENTILATION SYSTEM TYPE (Check one): ^ Intermittent Whole House Ventilation Using Exhaust Fans (2006 VIAO 303.4.1) ^ Intermittent Whole House Ventilation Integrated With A Forced Air System (2006 VIAQ 303.4.2) ^ Intermittent Whole House Ventilation Using A Supply Fan (2006 VIAQ 303.4.3) ^ Intermittent Whole House Ventilation Using A Heat Recovery Ventilation System (2006 VIAQ 303.4.4) This project complies with the following: ^ The project is asingle-family residence or duplex. ^ The project is wood frame OR all the insulation is interior or exterior of the framing. ^ All building components will meet the requirements of the table below. ^ The building will meet all other provisions of the WSEC and VIAQ. WASHINGTON STATE ENERGY CODE PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS°'~ /C~cni~irnmcn4c hacPrl nn ~nnF V1/SFC' TahlP F-1. Ontinn IV) Glazing ,... .... ......- Glazing U-Factor . .... _____ Door _.. ____ Ceiling2 -_-_ Vaulted Wall12 Wall Wall " Floors B Slab AreatO % U- Ceiling' Above d Int° l B Ext l B On Grade of Floor Vertical Overhead" Factor Gra e e ow e ow Grade Grade ' Unlimited 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 'Adv' denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1-inch vented airspace above the insulation . Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturers specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U-factors from Table 10-6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Ovefiead glazing with U-factor of U=0.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U-factors determined in accordance with NFRC 100 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement. ~ ~ I ~:= THURSTON COUNTY DEVELOPMENT SERVICES _- '- 2006 WSEC PRESCRIPTIVE HEATING SYSTEM CALCULATION FORM '~~~~~~ pp p o~ APPLICANT NAME: Thy A N C£ ~ ~ ~ U I PROJECT ADDRESS: /O / 30 T~RR~ ~ C f ryN 5T x INSTRUCTIONS: STEP 1: Determine TOTAL ENVELOPE COMPONENT UA. ^ Multiply the PRESCRIPTIVE U-VALUE by the AREA of each component to find the ENVELOPE COMPONENT UA. For SLAB ON GRADE, multiply the PRESCRIPTIVE SLAB F-VALUE by the SLAB PERIMETER. ^ Add the ENVELOPE COMPONENT UA's to find the TOTAL ENVELOPE COMPONENT UA. 3~Z Zoe. 3 ~ STEP 2: Determine MAXIMUM HEATING SYSTEM SIZE. ^ Enter the TOTAL ENVELOPE COMPONENT UA (taken from table above) as the VALUE for both ENVELOPE COMPONENTS and DUCTS. Enter 0 (zero) as the VALUE for DUCTS if the building does not have a ducted heating system. Enter the volume of conditioned space in the building, in cubic feet, as the VALUE for AIR LEAKAGE. Volume of conditioned space =Conditioned floor area x Average ceiling height. ^ Multiply each VALUE by the modifier(s) to its right to find the HEAT LOAD CONTRIBUTION for each HEAT LOSS PATH. ^ Add the HEAT LOAD CONTRIBUTION'S to find the DESIGN HEAT LOAD for the building. Multiply the DESIGN HEAT LOAD by 1.5 to find the MAXIMUM HEATING SYSTEM SIZE. ~ FILE TERRA GLENN ST SE N ~~ h ~~. ® ~^ ~ - t~ ~ h ^ ._.. ~ . ^~ ~~ ~ ~ ~ ' ~ 1 _ _ (~ ~; ~ STE TANK 6' ~ `~ --. 6' ~j ~^^ o V~ ~~ ~/~+ 1 ~ o0 50.0' CALE: 1 "=20 FEET 0 10 20 SCA CONSULTING VINTAGE GREENS DRAWN BY: DPC CHECKED BY: SCA ~ ! GROUP LOT #36 1 DATE: 9/23/08 FILE NAME: alts plans 4200 BTH AVE SUITE 301 ~~'~~ LACEY, WA 98503 10130 TERRA GLENN ST SE CONSULTING GROUP360.493.8002 • 360.493.2476 FAX YELM, WA 98597 SCALE: AS NOTED: 1 -' YELM COMMUNITY SCHOOLS PO BOX 476 YELM WA 98597 Clerk: Croy Terminal; 1 Receipt: 86244 Manual Receipt: NTRIANCE N206-618-0483 TRIANCE GROUP INCORPORATED 12639 S~ 307TH ST AUBURN, UJA 98092 1/12/'009 10:01 AM Oty Item ________ __ ________Price 1 CPF2900 2140.00 MITIGATION 05-028 - VINTAGE GREEN - LOT 35 1 CPF290U 2140.00 MITIGATION 05-U28 - VINTAGE GREEN - LOT 36 subtotal: 4280.00 Tax: 0.00 Total: 4280.00 Check 4280.00 1221 a Change Due: 0.00 THANK YOU CITY OF YELM INSPECTION LOG PROJECT' / '~ ~ (O PERMIT NUMBER ADDRESS SET BACKS Date: ~ ~ ~ ~/ Corrections ' Z, l~ b ~ n ~t UNDER FLOOR ~ Corrections DRY WELL ~_~ Corrections j ~~~/~' FOOTING REBAR _ Date: ~~i~~ ~ WALL REBAR Footing ^ 12" ^ 16" Wall ^ 6" ^ 8" Required vents_ Corrections ,Date: ~ /~~/°' ~! Other Other_ ~" COMBINED FRAME/ XTE IOR SHEAR WALL INSPECTI N Hold downs ~~io L° 5 Shear Nailing ~_~ 7%' ~ Frame 3/L v Gas/Propane ~ .7/`-Y ~~~ j Plumbing ~ 2 ~~ S Mechanical ~~0 Corrections: INSULATION Gas ^Electric ^Other Foam and Seal ^Vapor barrier ^PVA Corrections:_3 ,Z~ ( ~! SHEET 120CK/SHEAR WALL NAIL Corrections://i~ c~ j FINAL ^Sewer Final ^Electrical ^ Civil Final ^Landscape Final ®C of O ^Address ^ Insulation ^ Site Drainage ^ Sidewalk Corrrections: