05-0458 Punchlist No 1 090707
City of Yelm
Community Development Department
105 Yelm Avenue West
P.O. Box 479
Yelm, WA 98597
September 7, 2007
Rainier General Development
14788 Berry Valley Road S.E.
Yelm, WA 98597
RE: Forrester Heights (Palisades West) Estates Subdivision – SUB-05-0458-YL
Preliminary Walk Thru
Mr. Bloom:
The City of Yelm Community Development Department has completed a Preliminary Walk Thru of the project site and listed some items that will need to be completed.
The following are items that need to be addressed:
After a preliminary walk thru of the project site, the following items need to be completed or replaced. These items are listed by the street in which they are located.
Water:
Has the developer paid for the Hydrant locks for this project.
The Booster Pump Station has not been built for this project. The water department will not final this project until it is operational.
Replace meter box
At lot 21, the irrigation control box and the sewer Carson box are only 2’ apart. 10’ of separation is required.
A broken Carson Box lid must be replaced at lot 22.
At lot 23, the irrigation control valve is 4’ from the sewer Carson box. 10’ of separation is required.
Sewer:
A broken Carson Box needs to be replaced at lot 7
A broken Carson Box needs to be replaced at lot 13
The valve needs to be exposed in the Carson box for lot 17
At lot 21, the irrigation control box and the sewer Carson box are only 2’ apart. 10’ of separation is required.
A broken Carson Box lid must be replaced at lot 22.
At lot 23, the irrigation control valve is 4’ from the sewer Carson box. 10’ of separation is required.
Civil items:
1. Pavement ADA ramp at bottom of the hill needs to be replaced as a 1” deep tire track in it, marked in Red.
2. Grade on the back of walk at lot # 24 needs to be brought up to 1 inch and 1 foot of back of walk.
Landscape items:
1. Hydroseeding required within stormpond and planter strips.
2. Remove or relocate debri adjacent to cul-de-sac area.
3. Trees along the east property line to be planted per conditions of approval prior to receiving certificate of occupancy for lots 11-16.
4. A sign for a residential development must not exceed 18 square feet in area and 5 feet in height. The existing sign must meet this criteria for approval.
Please review these items. If you have any questions or comments, please call me at (360) 458-8423 and I will be happy to further assist you.
Respectfully
City of Yelm Community Development
Steve Harrington
Civil Engineering Inspector
steveh@ci.yelm.wa.us