08-0030 HVAC Floor Plans 021208MM Oki HVAC ROOF Plan Scale: N.T.S. GAS PIPE LAYOUT �EGEN D LLJ PLUMBING FIXTURE COLD WATER PIPE (CW) HOT WATER PIPE (HW) C 0 HOT WATER RECIRC PIPE (HWC) SANITARY PIPE (SAN) VENT PIPE (V) 00 STORM PIPE (S) RAIN LEADER (RL) >< ROOF DRAIN (RD) --------- - ------ - OVERFLOW DRAIN (OD) CL GAS PIPE (G) STEAM PIPE (STM) --- - -- ---- CONDENSATE RTN. PIPE (COND) LO - - --------- HOSE BIBB/WALL HYDRANT oU BALL VALVE GATE VALE I GATE VALVE w/CAP E BALANCING VALVE GAS COCK/VALVE GLOBE VALVE 4-1 ANGLE GLO BE VALVE A,i -------- --- 3-WAY MOTORIZED VALVE U CONTROL VALVE T CHECK VALVE PRESSURE RELIEF VALVE ---- ------- PRESSURE REDUCING VALVE PRESSURE REDUCING STATION In'! BACKFLOW PREY. STATION PIPE CAP PIPE BREAK K PIPE UP PIPE DOWN PIPE TEE UP --------------- ­ ------ ---- ------- .. .... --- - - ----- PIPE TEE DOWN PIPE FLANGE UNION FLEX CONNECTION (PIPE) STRAINER AIR VENT PRESSURE GUAGE 11 THERMOMETER -_. _ - ----- HVAC EQUIPMENT NUMBER/ PLUMBING FIXTURE DESIGNATION RECTANGULAR DUCT SIZE ROUND/SPIRAL DUCT SIZE OVAL DUCT SIZE ...... ..... _7 1,F -- - ----- . ...... - -------- --- ----------- CEILING DIFFUSER SQUARE CEILING DIFFUSER ROUND d-4 LINEAR/SLOT DIFFUSER ------ ----- RETURN AIR/EXHAUST GRILLE WEATHER LOUVER/WALL GRILLE SUPPLY AIR ARROW RETURN AIR/EXHAUST ARROW THERMOSTAT/SENSOR -_-------_ _ ---------- --- - SPIN-IN w/VOLUME DAMPER .. ............ 01MMI FLEX DUCT - ----- 7_17 '_ -- -------- DUCT, RECT ROUND ---- - ----- SOUNDLINED DUCT DUCTBORD SUPPLY AIR DUCT DOWN ......... . .. SUPPLY AIR DUCT UP RET/EXH DUCT DOWN ---------- RET/EXH DUCT UP -- ---- ----- ROUND/SPIRAL DUCT DOWN 'J ROUND/SPIRAL DUCT UP J, RECT DUCT BREAK ROUND/SPIRAL DUCT BREAK RECT ELBOW w/TURN VANES RADIUS ELBOW TRANSITION SQUARE-ROUND TRANSITION FLEX CONNECTOR 0 EQPT. FIRE DAMPER SMOKE DAMPER VOLUME DAMPER (VD) VOL. DMPR. w/REMOTE OPER. _j MOTORIZED DAMPER HYDRONIC WATER SUPPLY I Wr ' HYDRONIC WATER RETURN CONDENSER WATER SUPPLY ------ ---- ------ - ------ CONDENSER WATER RETURN CHILLED WATER SUPPLY CHILLED WATER RETURN MM Oki HVAC ROOF Plan Scale: N.T.S. GAS PIPE LAYOUT fn a 0 0 0 U) X W Zz 0 I.- W 04 CD 4-J _0 Uj V) CL L_ 0 0 E: U 2/7 L 40- e-11 Q) LLJ In z;-- X 0 LL- 00 C 0 0 L0 M LO 00 (C) r10 C14 (0 n 0 00 0 if) - LO < >< 0-r - rl- a: :3 _00000 CL Z 0 n V) __' -t >,a) LO — LO :3 :3 C-4 N 0 LO V) 0- -'_� . V) fn a 0 0 0 U) X W Zz 0 I.- W 04 CD 4-J _0 Uj V) CL L_ 0 0 E: U 2/7 L 40- 0 Z 0) C C 0 4_j 0 0 U >< CL fn a 0 0 0 U) X W Zz 0 I.- W 04 CD 4-J _0 Uj V) CL L_ 0 0 E: U 2/7 L 40- 0) U >< CL Uj Uj E W oU 3) < q_ E CD 4-1 Uj LU U') fu r- U 108 Permit Drawings These drawings have been developed for the exclusive use of Sound Heating & Air Conditioning, Inc. I The drawings are conceptual & schematic in scope and are to be ONLY used with written permission M-1 RECEIVE of Sound Heating & Air Conditioning, Inc. F4`68 1008 RTU 1,3 RTU 2 R-3 i t� a 3/4" PVC CONDINSATI DRAIN I YORK / DJ0361408P YORK / DJ060N10P 37 1 26 59 1 43 13.5 1 G SEER 13.4 1 G SEER d RTU 100K I 79K i 80.5 i 1200 i .6 i 1.5 125K I 99K 1 80.5 1 2000 1 .6 1 1.5 N I LEGEND L,.._ PLUMBING FIXTURE - COLD WATER PIPE (CW) E HOT WATER PIPE (HW) _.,_ ...:.:w .._._. HOT WATER- PIPE (HWC) -` At,! TRECIRC SANITARY PIPE (SAN) _..._ __...._ _..._ _ VENT PIPE (V) i STORM PIPE (S) ' d Ifl RAIN LEADER (RL) s, ROOF DRAIN (RD) 7 L� _. _ . - -- __ _._ _ _ ._. _ .._ _. _... __ _ _ ._ __. .. ..... OVERFLOW DRAIN (OD) N� GAS PIPE (G) V) :3 STEAM PIPE (STM) 01,0 CONDENSATE RTN. PIPE (COND) -WHOSE BI BB /WALL HYDRANT s(,,- --- ._ ------ _ BALL VALVE is - GATE VALE r i I GATE VALVE w /CAP I ° I ._..____.. ........ ___... BALANCING VALVE r..- GAS COCK /VALVE 1 1. 1 -.... GLOBE VALVE �..__ _ ANGLE GLOBE VALVE 3 —WAY MOTORIZED VALVE CONTROL VALVE j-, CHECK VALVE ,^ } PRESSURE RELIEF VALVE - �: -- - PRESSURE REDUCING VALVE { - - PRESSURE REDUCING STATION c5- -- BACKFLOW PREY. STATION 1I PIPE CAP : PIPE BREAK t ,< PIPE UP PIPE DOWN PIPE TEE UP PIPE TEE DOWN PIPE FLANGE UNION - E FLEX CONNECTION (PIPE) STRAINER _._..;s....— AIR VENT PRESSURE GUAGE THERMOMETER HVAC EQUIPMENT NUMBER/ PLUMBING FIXTURE DESIGNATION ' { I - RECTANGULAR DUCT SIZE 1 I ROUND /SPIRAL DUCT SIZE OVAL DUCT SIZE l @kij CEILING DIFFUSER — SQUARE 4� z1 CEILING DIFFUSER — ROUND LINEAR /SLOT DIFFUSER f RETURN AIR EXHAUST GRILLE WEATHER LOUVER /WALL GRILLE SUPPLY AIR ARROW .___ ......_._ ... RETURN AIR /EXHAUST ARROW 1j) THERMOSTAT /SENSOR SPIN IN w /VOLUME DAMPER I!' 00h FLEX DUCT (^-) ry DUCT, RECT (') / ROUND (N) SOUNDLINED DUCT /DUCTBORD SUPPLY AIR DUCT DOWN g'E 1 SUPPLY AIR DUCT UP RET /EXH DUCT DOWN (`) _ RET /EXH DUCT UP (`) 1 ROUND /SPIRAL DUCT DOWN (N) ROUND/SPIRAL DUCT _r d VUP RECT DUCT BREAK 1 ROUND /SPIRAL DUCT BREAK ' 1 RECT ELBOW w TURN VANES _r RADIUS ELBOW 1 � t" TRANSITION I I. SQUARE —ROUND TRANSITION FLEX CONNECTOR 0 EQPT FIRE DAMPER ._. _ SMOKE DAMPER VOLUME DAMPER VD } 66F VOL. DMPR. w /REMOTE OPER. MOTORIZED DAMPER _.H WIS HYDRONIC WATER SUPPLY HYDRONIC WATER RETURN t; CONDENSER WATER SUPPLY f Vs1 CONDENSER WATER RETURN EI'= CHILLED WATER SUPPLY I -CA 11,-� - CHILLED WATER RETURN RTU 1,3 RTU 2 R-3 i t� a 3/4" PVC CONDINSATI DRAIN I YORK / DJ0361408P YORK / DJ060N10P 37 1 26 59 1 43 13.5 1 G SEER 13.4 1 G SEER d RTU 100K I 79K i 80.5 i 1200 i .6 i 1.5 125K I 99K 1 80.5 1 2000 1 .6 1 1.5 HVAC Floor Plan Scale: N.T.S. 17.9 29.1 208/3 1 ECONO 1 695 1 w/24 HR — 7 DAY PROG T —STAT 208/3 1 ECONO 1 710 1 w/24 HR — 7 DAY PROG T —STA J 1 I s I t i i DUCT INSULATION MUST MEET THE REQUIREMENTS OF WSEC, SENTION 1414.2 & TABLE 14 -5 DUCT WORK INSULATION FOR CONDITION SPACES R -4, UNCONDITIONED SPACE IS R -8 AUTOMATIC SHUT —OFF, SMOKE DETECTOR(S) IN THE MAIN RETURN AIR DUCTS ARE NEEDED IF THE UNIT(S), SHARE THE SAME COMMON AIR ATMOSPHERE OR ZONE, IF THE UNIT(S) ARE GREATER THEN 2000 CFM. INTERNATIONAL MECHANICAL CODE 2003 SECTION, 606,606.2.1 HVAC UNIT OR A COOLING UNIT HAVING OVER 1900 CFM, OR 54 MBH WILL NEED AN ECONOMIZER. WSEC, SECTION, 1423 EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTIONS. ALL HVAC EPUIPMENT TO BE LABELED TO THE SPACE SERVED. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE — VERTICAL AT 12' -0" MAX., HARIZONTAL AT 10' -0" MAX.WITH STRAP, OR 7' -0" MAX. PROVIDE AN ANGLE TYPE SEISMIC BRACE. SMACNA STANDARDS. THERMOSTAT TO HAVE NIGHT SETBACK AND SEVEN DAY TYPE, WITH 5 DEGREE DEADBAND. MAXIMUM OF THERMOSTAT MUST BE SET NO MORE THAN 48" ABOVE FLOOR WITH CLEAR REACH RANGE, UNOBSTRUCTED IN FRONT. SECTION 308, ANSI A117 -1 THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 1416 WXEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS —BUILT DRAWINGS, SUBMITTALS, 0 & M MANUALS, SYSTEM BALANCE REPORT, AND A COMMISSIONING REPORT. SUBMITTED TO THE OWNER BEFORE A FINAL INSPECTION IS CALLED IN FOR. MECHANICAL EQUIPMENT ON A ROOF OR NEAR THE EDGE. GUARDS SHALL BE PROVIDED WHERE APPLIANCES, EPUIPMENT, FANS OR OTHER COMPONENTS THAT REQUIRE SERVICE ARE LOCATTED WITHIN 10 FEET (3048) OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE BELOW. THEGUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A 21— INCH — DIAMETER (533 MM) SPHERE. IBC — 06 ED, SECTION 1013.5 DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC 1414.1 DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -18. EXTENT OF SEALING IS AS FOLLOWS: 1. STATIC PRESSURE: 1/2" TO 2 ": SEAL TRANSVERSE JOINTS. 2. STATIC PRESSUR 2: 2" TO 3 ": SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. 3. STATIC PRESSURE: ABOVE 3 ": SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS. N I r U � In 4-- X i, 0L HVAC Floor Plan Scale: N.T.S. 17.9 29.1 208/3 1 ECONO 1 695 1 w/24 HR — 7 DAY PROG T —STAT 208/3 1 ECONO 1 710 1 w/24 HR — 7 DAY PROG T —STA J 1 I s I t i i DUCT INSULATION MUST MEET THE REQUIREMENTS OF WSEC, SENTION 1414.2 & TABLE 14 -5 DUCT WORK INSULATION FOR CONDITION SPACES R -4, UNCONDITIONED SPACE IS R -8 AUTOMATIC SHUT —OFF, SMOKE DETECTOR(S) IN THE MAIN RETURN AIR DUCTS ARE NEEDED IF THE UNIT(S), SHARE THE SAME COMMON AIR ATMOSPHERE OR ZONE, IF THE UNIT(S) ARE GREATER THEN 2000 CFM. INTERNATIONAL MECHANICAL CODE 2003 SECTION, 606,606.2.1 HVAC UNIT OR A COOLING UNIT HAVING OVER 1900 CFM, OR 54 MBH WILL NEED AN ECONOMIZER. WSEC, SECTION, 1423 EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTIONS. ALL HVAC EPUIPMENT TO BE LABELED TO THE SPACE SERVED. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE — VERTICAL AT 12' -0" MAX., HARIZONTAL AT 10' -0" MAX.WITH STRAP, OR 7' -0" MAX. PROVIDE AN ANGLE TYPE SEISMIC BRACE. SMACNA STANDARDS. THERMOSTAT TO HAVE NIGHT SETBACK AND SEVEN DAY TYPE, WITH 5 DEGREE DEADBAND. MAXIMUM OF THERMOSTAT MUST BE SET NO MORE THAN 48" ABOVE FLOOR WITH CLEAR REACH RANGE, UNOBSTRUCTED IN FRONT. SECTION 308, ANSI A117 -1 THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 1416 WXEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS —BUILT DRAWINGS, SUBMITTALS, 0 & M MANUALS, SYSTEM BALANCE REPORT, AND A COMMISSIONING REPORT. SUBMITTED TO THE OWNER BEFORE A FINAL INSPECTION IS CALLED IN FOR. MECHANICAL EQUIPMENT ON A ROOF OR NEAR THE EDGE. GUARDS SHALL BE PROVIDED WHERE APPLIANCES, EPUIPMENT, FANS OR OTHER COMPONENTS THAT REQUIRE SERVICE ARE LOCATTED WITHIN 10 FEET (3048) OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE BELOW. THEGUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A 21— INCH — DIAMETER (533 MM) SPHERE. IBC — 06 ED, SECTION 1013.5 DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC 1414.1 DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -18. EXTENT OF SEALING IS AS FOLLOWS: 1. STATIC PRESSURE: 1/2" TO 2 ": SEAL TRANSVERSE JOINTS. 2. STATIC PRESSUR 2: 2" TO 3 ": SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. 3. STATIC PRESSURE: ABOVE 3 ": SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS. 0 C 0 0 •X a y 3 0 a� a M Q} . ID O p C: V Q � W CL ��U O O L_ @ LL ` IU Cc� wO� Q l w >! 0� QCw _ (� F-- U V) }- I RE s Permit 2/7/08 Drawings These drawings have been developed for the exclusive use of Sound Heating & Air Conditioning, Inc. !" F;NWflf, _" The drawings are conceptual & schematic in scope and are to be ONLY used with written permission M-1 of Sound Heating & Air Conditioning, Inc. #: N Li.l U � In 4-- X 0L w co E 0) 0Lnm LO 00� +, 0 Q raj O c0 �L0 Lr)Q I < 0-r-- r-- = :3 00 00 0 N� �L�::) V) :3 —1 NN0 s Ln0a. .V) 0 C 0 0 •X a y 3 0 a� a M Q} . ID O p C: V Q � W CL ��U O O L_ @ LL ` IU Cc� wO� Q l w >! 0� QCw _ (� F-- U V) }- I RE s Permit 2/7/08 Drawings These drawings have been developed for the exclusive use of Sound Heating & Air Conditioning, Inc. !" F;NWflf, _" The drawings are conceptual & schematic in scope and are to be ONLY used with written permission M-1 of Sound Heating & Air Conditioning, Inc. #: LEGEND !. ?_ PLUMBING FIXTURE i - COLD WATER PIPE (CW) - HOT WATER PIPE (HW) - - HOT WATER RECIRC PIPE (HWC) :.ties-# - SANITARY PIPE (SAN) VENT PIPE (V) - STORM PIPE (S) 4)14 RAIN_ LEADER (RL) Rf i ROOF DRAIN _(RD_).__ OVERFLOW DRAIN (OD) 4' PLUMBING FIXTURE DESIGNATION - - GAS PIPE (G) I r'' °•� STEAM PIPE (STM) f" 12,­ CONDENSATE _ RTN PIPE (COND) j I HOSE BIBB /WALL HYDRANT 41) BALL VALVE I - GATE VALE GATE VALVE w /CAP T, BALANCING VALVE a { GAS COCK /VALVE {.� GLOBE VALVE 4 ANGLE GLOBE VALVE ' 3-WAY MOTORIZED VALVE -- CONTROL VALVE ,__ .._....._..._u_._.. _ CHECK VALVE ,._ _ _... _..,_... r_.__----- _.__._.__ .,.._ __ _ ..._.... ------------ . PRESSURE RELIEF VALVE _. _ _....._._ __._. `I .I _ ..._ _. _....... _.. PRESSURE REDUCING VALVE ( l PRESSURE REDUCING STATION - "iii - BACKFLOW PREY. STATION -° .. PIPE CAP -- PIPE BREAK i PIPE UP PIPE DOWN __ _ EF -1,2 NUTONE QTXEN110 (V. T. O.) e 00, :I i i� 500 CFM 500 CFM HVAC Floor Plan Scale: 1/4"=V-0" DUCT INSULATION MUS ",," MEET THE REQUIREMENTS OF WSEC, SENTION 1414.2 & TABLE 14 -5 DUCT WORK INSULATION FOR CONDITION SPACES R -4, UNCONDITIONED SPACE IS R -8 AUTOMATIC SHUT -OFF, SMOKE DETECTOR(S) IN THE MAIN RETURN AIR DUCTS ARE NEEDED IF THE UNIT(S), SHARE THE SAME COMMON AIR ATMOSPHERE OR ZONE. IF THE UNIT(S) ARE GREATER THEN 2000 CFM. INTERNATIONAL MECHANICAL CODE 2003 SECTION, 606,606.2.1 HVAC UNIT OR A COOLING UNIT HAVING OVER 1900 CFM, OR 54 MBH WILL NEED AN ECONOMIZER. WSEC, SECTION, 1423 EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTIONS. ALL HVAC EPUIPMENT TO BE LABELED TO THE SPACE SERVED. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE - VERTICAL AT 12' -0" MAX., HARIZONTAL AT 10' -0" MAX.WITH STRAP, OR 7' -0" MAX. PROVIDE AN ANGLE TYPE SEISMIC BRACE. SMACNA STANDARDS. THERMOSTAT TO HAVE NIGHT SETBACK AND SEVEN DAY TYPE, WITH 5 DEGREE DEADBAND. MAXIMUM OF THERMOSTAT MUST BE SET NO MORE THAN 48" ABOVE FLOOR WITH CLEAR REACH RANGE, UNOBSTRUCTED IN FRONT. SECTION 308, ANSI A117 -1 THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 1416 WXEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, 0 & M MANUALS, SYSTEM BALANCE REPORT, AND A COMMISSIONING REPORT. SUBMITTED TO THE OWNER BEFORE A FINAL INSPECTION IS CALLED IN FOR. MECHANICAL EQUIPMENT ON A ROOF OR NEAR THE EDGE. GUARDS SHALL BE PROVIDED WHERE APPLIANCES, EPUIPMENT, FANS OR OTHER COMPONENTS THAT REQUIRE SERVICE ARE LOCATTED WITHIN 10 FEET (3048) OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE BELOW. THEGUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A 21- INCH - DIAMETER (533 MM) SPHERE. IBC - 06 ED, SECTION 1013.5 DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC 1414.1 DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -18. EXTENT OF SEALING IS AS FOLLOWS: 1. STATIC PRESSURE: 4/2" TO 2 ": SEAL TRANSVERSE JOINTS. 2. STATIC PRESSUR 2: 2" TO 3 ": SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. 3. STATIC PRESSURE: ABOVE 3 ": SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS, NREC FORMS, DUCTING PLANS (BALANCING FEATURES) AS WELL AS VIAQ INFORMATION IS REQUIRED ALONG NTH A MECHANICAL PERMIT AT THE TIME OF THE TENANT IMPROVEMENT PERMIT. IMC, SENTION, 306.5 EQUIPMENT AND APPLIANCES ON ROOFS OR ELEVATED STRUCTURSES. WHERE EQUIPMENT AND APPLIENCES REQUIRING ACCESS ARE INSTALLED ON ROOFS OR ELECVATED STRUCTURES AT A HEIGHT EXCEEDING 16 FEET (4877 MM), SUCH ACCESS SHALL BE PROVIDED BY A PERMANENT APPROVED MEANS OF ACCESS, THE EXTENT OF WHICH SHALL BE FROM GRADE OR FLOOR LEVEL TO THE EQUIPMENT AND APPLIANCES. LEVEL SERVICES SPACE. SUCH ACCESS SHALL NOT REQUIRE CLIMBING OVER OBSTRUCTIONS GREATER THAN 30 INCHES (762 MM) HIGH OR WALKING ON ROOFS HAVING A SLOPE GREATER THAN 4 UNITS VERTICAL IN 12 UNITS HARIZONTAL (33- PERCENT SLOPE). PERMANENT LADDERS INSTALLED TO PROVIDE THE REQUIRED ACCESS SHALL COMPLY WITH THE FOLLOWING MINIMUM DESIGN CRITERIA: 1. THE SIDE RAILING SHALL EXTEND ABOVE THE PARAPET OR ROOF EDGE NOT LESS THAN 30 INCHES (762 MM) 2. LADDERS SHALL HAVE A RUNG SPACING NOT TO EXCEED 14 INCHES (356 MM) ON CENTER. 3. LADDERS SHALL HAVE A TOE SPACING NOT LESS THATN 6 INCHES (152 MM) DEEP. 4. THERE SHALL BE A MINIMUM OF 18 INCHES (457 MM) BETWEEN RAILS. 5. RUNGS SHALL HAVE A MINIMUM 0.75 -INCH (19 MM) DIAMETER AND BE CAPABLE OF WITHSTANDING A 300 -PUND (136.1 KG) LOAD. 6. LADDERS OVER 30 FEET (9144 MM) IN HEIGHT SHALL BE PROVIDED WITH OFFSET SECTIONS AND LANDINGS CAPABLE OF WITHSTANDING 100 POUNDS (488.2 KG /M2) PER SQUARE FOOT. 7. LADDERS SHALL BE AGAINST CORROSION BY APPROVED MEANS. CATWALKS INSTALLED TO PROVIDE THE REQUIRED ACCESS SHALL BE NOT LESS THAN 24 INCHES (610 MM) WIDE AND SMALL HAVE RAILINGS AS REQUIRED FOR SERVICE PLATFORMS. EXCEPTION: THIS SECTION SHALL NOT APPLYTO GROUP R -3 OCUUPANCIES. 306.6 SLOPED. _.__.._ _ ----- ____ _ _....___ _....__.. _._..___._._._. _.._._ ___._ _ ._._. I These drawings have been developed for the exclusive use of Sound Heating & Air Conditioning, Inc. The drawings are conceptual & schematic in scope and are to be ONLY used with written permission of Sound Heatina & Air Conditioning Inc PIPE TEE UP i - PIPE TEE DOWN II PIPE FLANGE UNION t - FLEX CONNECTION (PIPE) STRAINER - `,` AIR VENT 00 PRESSURE GUAGE 'I¢ . THERMOMETER __... ... - -------- _. HVAC EQUIPMENT NUMBER/ 4' PLUMBING FIXTURE DESIGNATION N RECTANGULAR DUCT SIZE I r'' °•� ROUND /SPIRAL DUCT SIZE f" 12,­ OVAL DUCT SIZE CEILING DIFFUSER - SQUARE {`$ CEILING DIFFUSER - ROUND m- .0 LINEAR /SLOT DIFFUSER RETURN AIR /EXHAUST GRILLE WEATHER LOUVER /WALL GRILLE U SUPPLY AIR ARROW RETURN AIR /EXHAUST ARROW T THERMOSTAT /SENSOR ` SPIN -IN w /VOLUME DAMPER !IIIIi110 FLEX DUCT e.... DUCT, RECT (') / ROUND (N) SOUNDLINED DUCT /DUCTBORD `I .I SUPPLY AIR DUCT DOWN ( l SUPPLY AIR DUCT UP 1 l RET /EXH DUCT DOWN _I RET /EXH DUCT UP (') ROUND /SPIRAL DUCT DOWN (N) i ROUND /SPIRAL DUCT UP RECT DUCT BREAK ROUND /SPIRAL DUCT BREAK RECT ELBOW w /TURN VANES i r RADIUS ELBOW N I. TRANSITION i SQUARE ROUND TRANSITION FLEX CONNECTOR a EQPT i FIRE DAMPER 1 � SMOKE DAMPER j VOLUME DAMPER VD -.. FS. `= VOL. DMPR. w /REMOTE OPER. 1I, MOTORIZED DAMPER `1 HYDRONIC WATER SUPPLY -"I IWR HYDRONIC WATER RETURN rws CONDENSER WATER SUPPLY CONDENSER WATER RETURN i iIE> CHILLED WATER SUPPLY CHILLED WATER RETURN __ _ EF -1,2 NUTONE QTXEN110 (V. T. O.) e 00, :I i i� 500 CFM 500 CFM HVAC Floor Plan Scale: 1/4"=V-0" DUCT INSULATION MUS ",," MEET THE REQUIREMENTS OF WSEC, SENTION 1414.2 & TABLE 14 -5 DUCT WORK INSULATION FOR CONDITION SPACES R -4, UNCONDITIONED SPACE IS R -8 AUTOMATIC SHUT -OFF, SMOKE DETECTOR(S) IN THE MAIN RETURN AIR DUCTS ARE NEEDED IF THE UNIT(S), SHARE THE SAME COMMON AIR ATMOSPHERE OR ZONE. IF THE UNIT(S) ARE GREATER THEN 2000 CFM. INTERNATIONAL MECHANICAL CODE 2003 SECTION, 606,606.2.1 HVAC UNIT OR A COOLING UNIT HAVING OVER 1900 CFM, OR 54 MBH WILL NEED AN ECONOMIZER. WSEC, SECTION, 1423 EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTIONS. ALL HVAC EPUIPMENT TO BE LABELED TO THE SPACE SERVED. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE - VERTICAL AT 12' -0" MAX., HARIZONTAL AT 10' -0" MAX.WITH STRAP, OR 7' -0" MAX. PROVIDE AN ANGLE TYPE SEISMIC BRACE. SMACNA STANDARDS. THERMOSTAT TO HAVE NIGHT SETBACK AND SEVEN DAY TYPE, WITH 5 DEGREE DEADBAND. MAXIMUM OF THERMOSTAT MUST BE SET NO MORE THAN 48" ABOVE FLOOR WITH CLEAR REACH RANGE, UNOBSTRUCTED IN FRONT. SECTION 308, ANSI A117 -1 THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 1416 WXEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, 0 & M MANUALS, SYSTEM BALANCE REPORT, AND A COMMISSIONING REPORT. SUBMITTED TO THE OWNER BEFORE A FINAL INSPECTION IS CALLED IN FOR. MECHANICAL EQUIPMENT ON A ROOF OR NEAR THE EDGE. GUARDS SHALL BE PROVIDED WHERE APPLIANCES, EPUIPMENT, FANS OR OTHER COMPONENTS THAT REQUIRE SERVICE ARE LOCATTED WITHIN 10 FEET (3048) OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE BELOW. THEGUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A 21- INCH - DIAMETER (533 MM) SPHERE. IBC - 06 ED, SECTION 1013.5 DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC 1414.1 DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -18. EXTENT OF SEALING IS AS FOLLOWS: 1. STATIC PRESSURE: 4/2" TO 2 ": SEAL TRANSVERSE JOINTS. 2. STATIC PRESSUR 2: 2" TO 3 ": SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. 3. STATIC PRESSURE: ABOVE 3 ": SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS, NREC FORMS, DUCTING PLANS (BALANCING FEATURES) AS WELL AS VIAQ INFORMATION IS REQUIRED ALONG NTH A MECHANICAL PERMIT AT THE TIME OF THE TENANT IMPROVEMENT PERMIT. IMC, SENTION, 306.5 EQUIPMENT AND APPLIANCES ON ROOFS OR ELEVATED STRUCTURSES. WHERE EQUIPMENT AND APPLIENCES REQUIRING ACCESS ARE INSTALLED ON ROOFS OR ELECVATED STRUCTURES AT A HEIGHT EXCEEDING 16 FEET (4877 MM), SUCH ACCESS SHALL BE PROVIDED BY A PERMANENT APPROVED MEANS OF ACCESS, THE EXTENT OF WHICH SHALL BE FROM GRADE OR FLOOR LEVEL TO THE EQUIPMENT AND APPLIANCES. LEVEL SERVICES SPACE. SUCH ACCESS SHALL NOT REQUIRE CLIMBING OVER OBSTRUCTIONS GREATER THAN 30 INCHES (762 MM) HIGH OR WALKING ON ROOFS HAVING A SLOPE GREATER THAN 4 UNITS VERTICAL IN 12 UNITS HARIZONTAL (33- PERCENT SLOPE). PERMANENT LADDERS INSTALLED TO PROVIDE THE REQUIRED ACCESS SHALL COMPLY WITH THE FOLLOWING MINIMUM DESIGN CRITERIA: 1. THE SIDE RAILING SHALL EXTEND ABOVE THE PARAPET OR ROOF EDGE NOT LESS THAN 30 INCHES (762 MM) 2. LADDERS SHALL HAVE A RUNG SPACING NOT TO EXCEED 14 INCHES (356 MM) ON CENTER. 3. LADDERS SHALL HAVE A TOE SPACING NOT LESS THATN 6 INCHES (152 MM) DEEP. 4. THERE SHALL BE A MINIMUM OF 18 INCHES (457 MM) BETWEEN RAILS. 5. RUNGS SHALL HAVE A MINIMUM 0.75 -INCH (19 MM) DIAMETER AND BE CAPABLE OF WITHSTANDING A 300 -PUND (136.1 KG) LOAD. 6. LADDERS OVER 30 FEET (9144 MM) IN HEIGHT SHALL BE PROVIDED WITH OFFSET SECTIONS AND LANDINGS CAPABLE OF WITHSTANDING 100 POUNDS (488.2 KG /M2) PER SQUARE FOOT. 7. LADDERS SHALL BE AGAINST CORROSION BY APPROVED MEANS. CATWALKS INSTALLED TO PROVIDE THE REQUIRED ACCESS SHALL BE NOT LESS THAN 24 INCHES (610 MM) WIDE AND SMALL HAVE RAILINGS AS REQUIRED FOR SERVICE PLATFORMS. EXCEPTION: THIS SECTION SHALL NOT APPLYTO GROUP R -3 OCUUPANCIES. 306.6 SLOPED. _.__.._ _ ----- ____ _ _....___ _....__.. _._..___._._._. _.._._ ___._ _ ._._. I These drawings have been developed for the exclusive use of Sound Heating & Air Conditioning, Inc. The drawings are conceptual & schematic in scope and are to be ONLY used with written permission of Sound Heatina & Air Conditioning Inc N W U� U) 4= X 500 CFM 500 CFM HVAC Floor Plan Scale: 1/4"=V-0" DUCT INSULATION MUS ",," MEET THE REQUIREMENTS OF WSEC, SENTION 1414.2 & TABLE 14 -5 DUCT WORK INSULATION FOR CONDITION SPACES R -4, UNCONDITIONED SPACE IS R -8 AUTOMATIC SHUT -OFF, SMOKE DETECTOR(S) IN THE MAIN RETURN AIR DUCTS ARE NEEDED IF THE UNIT(S), SHARE THE SAME COMMON AIR ATMOSPHERE OR ZONE. IF THE UNIT(S) ARE GREATER THEN 2000 CFM. INTERNATIONAL MECHANICAL CODE 2003 SECTION, 606,606.2.1 HVAC UNIT OR A COOLING UNIT HAVING OVER 1900 CFM, OR 54 MBH WILL NEED AN ECONOMIZER. WSEC, SECTION, 1423 EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTIONS. ALL HVAC EPUIPMENT TO BE LABELED TO THE SPACE SERVED. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE - VERTICAL AT 12' -0" MAX., HARIZONTAL AT 10' -0" MAX.WITH STRAP, OR 7' -0" MAX. PROVIDE AN ANGLE TYPE SEISMIC BRACE. SMACNA STANDARDS. THERMOSTAT TO HAVE NIGHT SETBACK AND SEVEN DAY TYPE, WITH 5 DEGREE DEADBAND. MAXIMUM OF THERMOSTAT MUST BE SET NO MORE THAN 48" ABOVE FLOOR WITH CLEAR REACH RANGE, UNOBSTRUCTED IN FRONT. SECTION 308, ANSI A117 -1 THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 1416 WXEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, 0 & M MANUALS, SYSTEM BALANCE REPORT, AND A COMMISSIONING REPORT. SUBMITTED TO THE OWNER BEFORE A FINAL INSPECTION IS CALLED IN FOR. MECHANICAL EQUIPMENT ON A ROOF OR NEAR THE EDGE. GUARDS SHALL BE PROVIDED WHERE APPLIANCES, EPUIPMENT, FANS OR OTHER COMPONENTS THAT REQUIRE SERVICE ARE LOCATTED WITHIN 10 FEET (3048) OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE BELOW. THEGUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A 21- INCH - DIAMETER (533 MM) SPHERE. IBC - 06 ED, SECTION 1013.5 DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC 1414.1 DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -18. EXTENT OF SEALING IS AS FOLLOWS: 1. STATIC PRESSURE: 4/2" TO 2 ": SEAL TRANSVERSE JOINTS. 2. STATIC PRESSUR 2: 2" TO 3 ": SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. 3. STATIC PRESSURE: ABOVE 3 ": SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS, NREC FORMS, DUCTING PLANS (BALANCING FEATURES) AS WELL AS VIAQ INFORMATION IS REQUIRED ALONG NTH A MECHANICAL PERMIT AT THE TIME OF THE TENANT IMPROVEMENT PERMIT. IMC, SENTION, 306.5 EQUIPMENT AND APPLIANCES ON ROOFS OR ELEVATED STRUCTURSES. WHERE EQUIPMENT AND APPLIENCES REQUIRING ACCESS ARE INSTALLED ON ROOFS OR ELECVATED STRUCTURES AT A HEIGHT EXCEEDING 16 FEET (4877 MM), SUCH ACCESS SHALL BE PROVIDED BY A PERMANENT APPROVED MEANS OF ACCESS, THE EXTENT OF WHICH SHALL BE FROM GRADE OR FLOOR LEVEL TO THE EQUIPMENT AND APPLIANCES. LEVEL SERVICES SPACE. SUCH ACCESS SHALL NOT REQUIRE CLIMBING OVER OBSTRUCTIONS GREATER THAN 30 INCHES (762 MM) HIGH OR WALKING ON ROOFS HAVING A SLOPE GREATER THAN 4 UNITS VERTICAL IN 12 UNITS HARIZONTAL (33- PERCENT SLOPE). PERMANENT LADDERS INSTALLED TO PROVIDE THE REQUIRED ACCESS SHALL COMPLY WITH THE FOLLOWING MINIMUM DESIGN CRITERIA: 1. THE SIDE RAILING SHALL EXTEND ABOVE THE PARAPET OR ROOF EDGE NOT LESS THAN 30 INCHES (762 MM) 2. LADDERS SHALL HAVE A RUNG SPACING NOT TO EXCEED 14 INCHES (356 MM) ON CENTER. 3. LADDERS SHALL HAVE A TOE SPACING NOT LESS THATN 6 INCHES (152 MM) DEEP. 4. THERE SHALL BE A MINIMUM OF 18 INCHES (457 MM) BETWEEN RAILS. 5. RUNGS SHALL HAVE A MINIMUM 0.75 -INCH (19 MM) DIAMETER AND BE CAPABLE OF WITHSTANDING A 300 -PUND (136.1 KG) LOAD. 6. LADDERS OVER 30 FEET (9144 MM) IN HEIGHT SHALL BE PROVIDED WITH OFFSET SECTIONS AND LANDINGS CAPABLE OF WITHSTANDING 100 POUNDS (488.2 KG /M2) PER SQUARE FOOT. 7. LADDERS SHALL BE AGAINST CORROSION BY APPROVED MEANS. CATWALKS INSTALLED TO PROVIDE THE REQUIRED ACCESS SHALL BE NOT LESS THAN 24 INCHES (610 MM) WIDE AND SMALL HAVE RAILINGS AS REQUIRED FOR SERVICE PLATFORMS. EXCEPTION: THIS SECTION SHALL NOT APPLYTO GROUP R -3 OCUUPANCIES. 306.6 SLOPED. _.__.._ _ ----- ____ _ _....___ _....__.. _._..___._._._. _.._._ ___._ _ ._._. I These drawings have been developed for the exclusive use of Sound Heating & Air Conditioning, Inc. The drawings are conceptual & schematic in scope and are to be ONLY used with written permission of Sound Heatina & Air Conditioning Inc U n Z Q 7 �c ,4"a O :' III O U Q V 1 0 0 V Cr X q) E 3 O a N co 0 N �r 0 iii .f V O O LL U Q „; ¢2/7 am O 4- N W U� U) 4= X 0)OL,m ��(0 4 N � P7 0 0 00 I Q LO LO �-��_ 00 00 p 4' Q N TLo Lo :) LO > >NNO LO V) 0- __ �U) U n Z Q 7 �c ,4"a O :' III O U Q V 1 0 0 V Cr X q) E 3 O a N co 0 N �r 0 iii .f V O O LL U Q „; ¢2/7 am O 4- Q Uj W E a aco U O��Q C1 E C M -1 (A".