08-0045 Fire Alarm System 013108MyffY E L E C T K/ C Inc_ COMMERCIAL•I N DUSTRIAL Kirby Electric Inc. PROPOSAL 4826 "B" St. NW Ste. 101 Telephone 12531 B59 -2000 Auburn, WA 98001 Fm (2531859-2363 SUBMITTALS FOR CREEK ST. PLAZA BLDG. A 1304 YELM AVE. SE YELM, WA FIRE ALARM SYSTEM SILENT KNIGHT 5700 ADRESSABLE PANEL SILENT KNIGHT ADRESSABLE SMOKE DETECOR SILENT KNIGHT ADRESSABLE PULL STATION SYSTEM SENSOR HORN /STORBES SYSTEM SENSOR STROBE ONLY SYSTEM SENSOR MODULE PLANS BATTERY CALCULATIONS VOLTAGE DROP CALCULATIONS January 30, 2007 DEREK MCCOY KIRBY ELECTIC 4826 B ST. NW, STE. 101 AUBURN, WA 98001 253.859.2000 RECEIVED JAN 312008 N C IntelliKnight® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control panel solution. IntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control /communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built -in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 600 -446 -6444, or in Minnesota, call 763 -493 -6435. Description 5700 performs drift compensation and calibration checks on each of the sensors in the system. The basic IntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial /parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 also features a powerful built -in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Up to 50 addressable points • Up to 125 zones and 125 output groups • Uses standard wire --no shielded or twisted pair required • Buift4n digital communicator. • Central station reporting by point or by zone • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC • Distributed, intelligent power • Drift compensation • 13 pre - programmed output cadences (including ANSI -3.41) and 4 programmable outputs • Notifcation circuits configurable as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power • Built -in synchronization for AMSECO, Gentex®, Faraday, System Sensors and Wheelock@ appliances • Built-in annunciator with 80- character LCD display RS-485 bus provides communication to system accessories • Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) • Improvements in SKSS deliver five times faster upload /downloads • Built-in RS -232 interface for programming via PC Built -in Form C trouble relay rated at 2.5A at 27.4 VDC • Two built -in Form C programmable relays rated at 2.5A at 27.4 VDC • Programmable date setting for Daylight Saving Time Electrical Specifications Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC Notification Power: 2.5A @ 27.4 VDC, power - limited Standby Current: 200 mA Alarm Current: 325 mA Notification /Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power - limited Battery Charging Capacity: 7.0 -35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet. Mechanical Specifications Dimensions: 12.75'W x 15.2 "Hx3.4'D (32.39 W x 38.42 H x 8.57 D cm) Weight: 11.5 Ibs.(5.2 kg) Color: Red MOdel 57DO Telephone Requirements FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, 8 NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfow, sprinkler supervisory (DACT non - coded) signalling services. Other Approvals: UL Listed; CSFM 7170- 0559:144; MEA 429 -92 -E Vol. XVL SILENT KNIGHT by Honeywell SLC Detectors S0505 -APS Addressable photoelectric smoke detector. SD505 -AIS Addressable ionization smoke detector. SD505 -AHS Absolute temperature heat detector Nat goes into alarm immediately if the temperature exceeds the programmable trip point. Trip point range Rom 135T -15TF (0- C -3PC). SD505 -6AB Six inch base for use with detector heads SD505 -APS, SD505 -AIS and SD505 -AHS. SD505-4AB Four inch base for use with detector heads SD505 -APS, SD505 -AIS, and SD505 -AHS. SDSO5 -BSB Six -inch sounder base hr use with existing sensor and base. Operates in single and multi - station modes and/or as a system sounder Requires 2 additional wires for power. SD505-61B Short circuit isolator base for SD505 -AHS, SD505 -APS, and SD505 -AIS rated... SDSO"RB Six -inch relay base for use with existing sensor and base. Provides one Form C co md. SD505-ADH Dud housing that date= smoke in HVAC ducts, SD505 -ADHR Dud detector base with relay. Provides Form C alarm contact. For use with SD505 -APS and 50505 -AIS sensors. Compatible with SD508 -DTS remote test switch. SD50g- PS /SD500 -PSDA SD5W-PS is a single action pull station and SD500 -PSDA is a dual action pull station. SLC Modules Model SD500 -AIM Dry contact input module for use with normally open dry contacts. It features an indicator LED W show alarm status. SDS00 -MIM Mini dry contact input module is a small version of the SD500 -AIM. For use with pull stations and other normally open dry contact inputs. SD500 -ANM Addressable notification module providing a single Class A or Class B notification circuit on the SLC. 50500 -ARM Addressable relay module that features two Form C output relays. Provides indicator LED to show output status. SDS00 -SDM Two -wire detector input module. Allows for the connection of conventional 2 -wire detectors on the SLC loop. Requires two additional wires for power. SD500 -LIM A short circuit isolator module for SLC devices. When a short occurs on the SLC loop, it is detected as a trouble, but all SLC devices protectetl by the isolator module continue to operate. 50500 -LED An LED driver capable of driving 80 LEDs through the SLC Icop. Up to 40 SD500 -LEDs can be used per system. S -BUS Accessories 5860 /R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighters key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expender that provides four additional power - limited notification appliance circuit outputs. 5880 LED00 Module Features 40 LED outputs, 8 normally open dry coread inputs and one piezo output. 58653 and 5865-4 Remote LED Annunciator Features 30 zi Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865,1 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial /Parallel Printer Interface Module Provides one parallel and one RS -232 serial port for connecting a printer to 5808. Use to print a real -time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite User - friendly Windows software for remote programming of 5700s using a PC. Upload and vies panel account information, event history, and detector status. 5670 Silent Knight Software Suite End -user facility management software allows viewing of detector status and event history As modem or direct connection. RIBS Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16- Wx10 -H x6-D (406 mm W x 254 mm H x 152 mm D) SD505 -DTS Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505 -ADHR. SILENT This document is not intended to be used for installation purposes. We by to ®.KNIGHT keep our product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 4.+ b/ Honeywell 7550 Meridian Circle Suite t W, Maple Grove, Mn 553694927. Phone. (800)328 -0103. Fax: (763)493 -6475. IntelliKnight 8 JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight MADE IN AMERICA FORMA 350392 Rev. D, 04106 Copyright 0 2006 Silent Knight Addressable , Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505 -APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505 -APS compensates automatically for contamination in the environment. And detector testing is simple even from a remote site. Like other IntelliKnight detector models, the SD505 -APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal - resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 -APS Analog / Addressable Photoelectric Type Smoke Detector The SD505 -APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsT based downloading software). Operation The SD505 -APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features • Low profile, 2 inches, including base • Simple and reliable addressing without mechanical switches • Automatic compensation for sensor contamination • Built -in fire test feature • Simple detector calibration testing through the control panel or remotely through a WindowsTm based computer software. • Vandal- resistance locking features • Field cleanable • UL listed, meets NFPA 72 Ch 7 requirements • CSFM approved • MEA approved • FM Approved LY SD505 -APS Smoke Detector Specifications Operating Voltage: 17-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Ambient Temperature: 32°F to 120 °F (0^C to 49^C) Mounting: 4" Square, 4" OCT. Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: 0 - 300 FPM Compatible Bases: SD505 -6AB (Sold Separately) (6" Base) SD505.4AB (4" Base) SILENT KNIGHT by Honeywell Model SD505 -APS Addressable Photoelectric Type Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505 -APS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505 -AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505 -APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. L01 Model SD505 -6AB Detector Base (front view) Diameter= 3- 15116' o_ • ' 1' Height • 2 inches, including base Model SD505 -APS Detector Head (front view) SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are ° -° subject to change without notice. For more information, contact Silent Knight by Honeywell 7650 Mandan Circe Suite 100, Maple Grove, Mn 553694927. Phone: (800)328 -0103, Fax: 17631493 -6475. MADE IN AMERICA FORM# 350225 Rev C,, 05/05 Copyright ® 2005 Silent Knight SD500 -PS and SD500 -PSDA Addressable Pull- Station IntelliKnight's addressable pull stations combine fast response with pin -point location ID. The SD500 -PS and SD500 -PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500- PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500 -PS /PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500 -PS & SD500 -PSDA Addressable Pull Station The SD500 -PS is a single action addressable fire pull station, and the SD500 - -PSDA is a dual action addressable fire pull station. The SD500- PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an IntelliKnight control panel. The SD500- PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold- plated to avoid risk of corrosion. The SD500- PS /PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features • UL Listed • CSFM listed • ADA compliant • Key reset (Same key as Silent Knight enclosures) • Surface mount back box available Terminals - accept up to 14 gauge wire • Extremely easy to operate • Corrosion - resistant gold - plated contacts. • Reflective label makes it easier to locate in low light Operation The SD500 -PS /PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500 -PS /PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDC Standby Current 55mA Alarm Current: .55mA SD500 -PS Ambient Temperature: 32 -F to 120 -F (WC to 49 °C) Mounting: Single gang box - Optional Red Sudace Mount Box P&SMBB SILENT KNIGHT SD500 -PS and SD500 -PSDA Addressable Pull- Station Engineering Specifications Manual pull station shall be addressable Module SD500- PS/SD500 -PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel. The label shall contain the words Fire Alan and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. R r III I �C-0 Mounting to Single Mounting to Optional Gang Electrical Box Surface Mount Box tVlf SD500 -PSDA I Installing SD500 -LK SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 800 - 446 -6444 or in Minnesota 763- 493 -6435 FAX 763- 493 -6475 World Wide Web: httpWrivin .silentknighLCOm e Wiwi �a..Ynr N'P-r Dimensions ° MADE IN AMERICA FORM# 3503x2, Re, 09103 Copyright 0 2003 Silent Knight Wiring xnrr e Wiwi �a..Ynr N'P-r Dimensions ° MADE IN AMERICA FORM# 3503x2, Re, 09103 Copyright 0 2003 Silent Knight f� SYSTEM Z4 SENSOR Selectable Output Horns, Strobes, and Horn /Strobes SpectrAlert'Advance selectable- output horns, strobes, and horrvstrobes are rich with features guaranteed to cut installation times and maximize profits. The SpectrAll Adlrana swMs of notification appliances is designed to simplify installations, with features such as plug in 0 designs, instant feedback messages to ensure correct installation of individual devices, and 11 field - selectable candela settings for wall and ceiling strobes and horNetrobes. When installing Advance products, first attach a universal mounting plate to a four -inch square, four inch octagon or double -gang junction box. The two -wire mounting plate attaches to a single -gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by Inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn7strobev (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. N Features • Electrically compatible with existing SpectrAlert products • Automatic selection of 12 -or 24-volt operation at 15 and 15/75 candela • Plug -in design • Field selectable candela settings on wall and ceiling units: 15,15/75, 30, 75, 95,110,115,135, 150,177,185 • Same mounting plate for wall- and ceiling -mount units • Shorting spring on mounting plate for continuity check before installation • Tam per resistant construction • Outdoor wall and ceiling products rated from -4TF to 151 °F • Design allows minimal intrusion into the back box Horn rated at 88 +dbA at 16 volts • Rotary switch for horn tone and three volume selections • Outdoor products UL listed to UL 1638 (strobe) and UL464 (horn) outdoor requirements • Outdoor products rainproof per UL 50 (NEMA 3R) • Compatible with MDL sync module Agency Listings draxWMa uL FM MEA orkel 1® LISTED arvawev approved '.. SpectrAlen Advance horn schoose, and horn /avobee shall mount to a standard � x I:.; inch back box, flinch octagon back box or double e -gang back box Two -wire products shall also mount to a Single going 2 x4 x 17 /vAreh back box. A universal mounting plate shall be Used for mounting ceiling and wall Voters. The notification appliance d¢uh win Ing shall terminate at the universal mounting plate. Alva, Sidi Alert Advance products, when used with the Sync{Trculf Module accessory shall be powered from a nonmded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Syna-C'acun Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and ITS vdb; 24-volt rated notification appliance credit outputs shall operate between 17 and 33 volts. Indoor Spectoden Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated a, or full -wave rectified, unfiltered power supply Strobes and horn /strobes shall have fieldselectable candela settings including 15,15/75.30 75.95. 110, 115,135, 150, 177, 1 U. strobe The strobe shall be a System Sensor SpectrNert Advance Model_ listed to Ill 1971 and shall be approved for fire protective semice.The strobe shell be wired as a primarysignaling notification appliance and romplywith the Americans wish Disabilities Aet requirements for visible signaling appliances, flashing at I Hzover the strobes entire operating voltage range. The strobe light shall consist of a xenon Flash tube and associated lens/reflectorsyuem Re horn/strobe robe COrobiro a S The horn /strobe shall be a System Sensory- sagnAlert Advance Model_ listedpl UAL 1971 and UL 464 and shall be approved for fire protective servfce. ThehoMSUObeshall bho,aas a pryer the Craning notification apg voltaandR withthe Americans with Disabilities A¢requirementsociateible Signaling applian<es.f1 he h ,at 1 Hz over the strobe's entire operating voltage range, to Swit a strobe light shall oral tnee- xenon ash tube and associated lente rnThssystemhiehorn Shall have three itions itop tionsandheprodutswi shbetweenatemporaltlnee-sand and aesoundporal(cornOnus) pattern.Theseopnonsare se[ bye multiple position switch.Onfour -wire pmtluas, the strobe shall be powered independently ofMe sountler.The horn on horn /strobe models shall operate on a coded or non -coded power supply Outdoor Products Spec[nAlen Advance outdoor horns, strobes and horNStrobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheicthe products shall Witted for use with a System Sensor outdoorAVeatherproof back box with half inch and three - fourths inch conduit entries. syrchronimtlon Module The module shall be a System Sensor Synctirmit model MDL listed to UL 464 and shall be approved for fire protective seryl module shall synchronize O 5peccouen strobes at l HZ and horns at temporal three. All while operating the st robes, the module shall silence the horns on horNS[robe models over single pair of wires The module shall mount to a 411/16 x 4 1/m x 2' /i inch bad box.The module shall also control two Style Y(class By circuits or one Style Z (doss A) circuit The module shall syndvouide multiple zone, Daisy chaining two or made synchronization modules together will synchronize all me mines they Notes: I. full Wave RCaified TWR) voltage is a non regulated, time varying power source that is used on some power supply and panel outputs. 2. P, 5, PC, and SC products will operate at 12V nominal only for 15 and 15/75 cd N L C UL Current Draw Data Temporal High I% 155 88 97 112 168 1% 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 % 101 160 184 194 201 Nointem;dcal High 142 161 103 112 126 181 203 221 229 Nor,temporal Medium 134 155 85 95 110 166 189 208 216 Non terni Low 132 154 % 90 105 161 IM 202 211 Candela Denting Horn Tones and Sound Output Data For K series products used atlow temperatures, listed osdi Faunas must be reduced In so,smance with this table ,..._...__.__, Temporal Listed Candela Candela rating at -40 °F 15 Do not use below 32°F 1595 30 75 95 95 O 8- 17.SVolts 1633yota 115 115 e- 17.5Wha t5- 33V0lU 15a Candela i MR Ix MR Sound Pattern dB K FWR DC FWR Standard 15' 123 128 66 71 Temporal High 57 55 69 25 Candela Range 1595- 142 148 77 81 Temporal Medum 44 49 58 69 31 NA NA 94 96 Temporal Low 38 44 44 48 75' NA NA 158 153 Non- temporal High 57 56 69 75 95' NA NA 181 176 Norrtemporal Medium 42 50 60 69 ma NA NA 202 195 Nomtemporal Low 41 44 50 50 115 NA NA 210 205 Coded Hqh 57 55 69 75 Temporal High I% 155 88 97 112 168 1% 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 % 101 160 184 194 201 Nointem;dcal High 142 161 103 112 126 181 203 221 229 Nor,temporal Medium 134 155 85 95 110 166 189 208 216 Non terni Low 132 154 % 90 105 161 IM 202 211 Candela Denting Horn Tones and Sound Output Data For K series products used atlow temperatures, listed osdi Faunas must be reduced In so,smance with this table ,..._...__.__, 8 -17.5 16-33 Switch Volts Volts Pasition Sound Patnm dB a fail a 2 Temporal Listed Candela Candela rating at -40 °F 15 Do not use below 32°F 1595 30 75 95 95 O Ila 110 115 115 135 76 15a 0 177 77 185 185 8 -17.5 16-33 Switch Volts Volts Pasition Sound Patnm dB a fail a 2 Temporal Medium 74 74 % 80 % m 95 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Norrtemporal High 82 82 88 98 93 92 100 100 5 Norntemporal Medium 78 78 85 85 90 90 98 98 6 Noretemporal Low 75 75 81 81 88 84 95 92 7' Cooled High 82 82 88 88 93 92 101 101 81 Coded Medium 76 78 85 85 SO 90 97 % 9' Ceded Low 75 75 81 81 88 85 96 92 15ectings 7,8, and 9 are not available on 2 -wire horNSttobe C SpectrAlert Advance Dimensions Sfi Wall-mi hohn/sttobes Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Wall weatherproof back box calling weatherproof back box Ceiling HorNStrobes (conVd.) PC2W^ 2 -wire HoMStrobe, Standard cd, White PC2WH^ 2 -wi1e Hiaw5trobe, High cd, Mine Wall Strobes 5R^ Strobe, Standard cd, Red SRH't Strobe, High cd, Red SRK Strobe, Standard cd, Red. Outdoor SRHK Strobe, High cd, Red, Outdoor SW Strobe, Standard cd, White SWH' Strobe, High on, White Ceiling HO trobes PC2R' 2 -wire HoMStrobe, Standard cd, Red PC2RH' 2,,m HOrNStrobe, Hach cd, Red PORK 2wna Horn/Stnobe, Standard od, Red, Outdoor PC2RHK 2-wire H.mrSadbe, High Per Red, Outdoor BE Back Bid Skirt, Wa11,Red BB5W -2 Back Box Skirt Well,White BBSC -2 Back Box Skirt, Ceiling. Red BBSCW -2 Back Be. Skirt, Ceiling. Whhe HRes: ' Add ' -F'to model number for plain housing (no FIRE'marking on cover), mg., P2R -P t Mel' SP'to model number for FUEGO'marking on co er, e.g. P2R -SP 3'Stardad cdf refers to strobes that include 15.1595130175,95, 110, arM 115 candela settlngs.Fllgh cd' refers to strobes that Include 135,150,177, and 1 BS candela settings. Al outdoor units ending in'rindude a weatherproof back box. SYSTEM 3825 Mao Avenue• 5t, Charles, IL Wp4 SE/VSOR Phone80USENSOR2•EaZ6 377fi495 BATTERY CALCULATIONS STANDBY DEVICES CURRENT CURRENT TOTAL(STANDBYI TOTAL (ALARM) 24 19.32 STANDBY ALARM 0.0833 0.342196 SK -5700 1 0.2 0.325 0.2 0.325 SK -MIM 3 0.055 0.055 0.165 0.165 SK -PULL STATION 7 0.055 0.055 0.385 0.385 SK -SMOKE 1 0.055 0.055 0.055 0.055 P2R 15 /30CD 4 0 0.079 0 0.316 15CD STROBE ONLY 7 0 0.066 0 0.462 P2R 75CD 4 0 0.176 0 0.704 P2R 110CD 8 0 0.212 0 1.696 SUM COLUMN FOR: 0.805 4.108 TOTAL LOAD REQUIREMENTS TOTAL STANDBY LOAD (AMPS) 0.805 24 19.32 ALARM LOAD (AMPS) 4.108 0.0833 0.342196 BATTERY AMP HOUR: 19.6622 TOTAL AMP HOURS REQUIRED: 23.59464 * Batteries will be 2 18amp /hr batteries