08-0030 Mechanical Summary 0212082006 2006 Washington State NorimsYdential Energy Code Compliance Foms State Nonresidential Energy Code Compliance Form July 2007 Project Info Project Address 1304 YELL AVE Date 2]7/2008 BUILDING ,X For Building Dept Use 3 - Fill out this line an PRJ -SUM Applicant Name: SOUND HEATING s A/c INC Applicant Address 5526 184TH s 8 PUPAS LUP NA Applicant Phone: 253 -e75-3350 Project Description ROOF TOP KNITS FOR SHELL FREEZE PROTECTION Briefly describe mechanical system type and features. 0 Includes Plans IDrawings must contain notes requireing compliance with commissioning requirements - Section 1416 Simple System 0 Complex System 0 Systems Analysis Compliance Option (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple s complex systems. ) Equipment Schedules The following Information is required to be incorporated with the mechanical equipment schedules on the plans_ For projects without plans, fill in the required information below. Coolin g Equipment Schedule Equip. ID Brand Name' Model No.' Capacity2 Muth Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location RTU 1611 YORK DJ036NOSP 100K 1200 LCONO 100 79 80.500 Heatin g Equipment Schedule Equip. ID Brand Name' Model No.' Capacity2 Btufh TOW CFM OSA cfm or Econo? Input Btuh Output Btuh Efflcienc a RTU 1611 YORK DJ036NOSP 100K 1200 LCONO 100 79 80.500 Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HPIGHP Flow Controls Location of Service ' If available. 2 As tested according to Table 14 -1A through 14 -1 G. 3 If required. ° Cop, HSPF, Combustion Efficiency, or AFIIE, as applicable. s Flow control types: variable air volume(VAV), constant volume (CV), of variable speed (VS). 2006 Washington State Nonresidential Energy Code Compliance Form System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling D Constant vol? [] Air cooled? ❑ Packaged sys? [] X20,000 Btuh? or Cooling Only. 0 Split system ? --Q Economizer included? if Heating Only: ] 5000 cfm? X70 / outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. =R�nce Heating Only <6000 Yes drn? No No 4- 84,000 Btuh? 'M 00b> -No or o—Ln Ad3acent to Yes Reference No 5ec�on1423 Total CE wo econor <240,OOO 1 or 10% Yes 054,000 Use Complex I Systems (section 1430) Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems Complex Systems requirements are applicable to this project, 2006 Washington State Nonresidential Energy Code Compliance Form Permit Plans r Mechanical cklist 2048 Wmehinl;Wn State Non residenbal Energy Code Cornpillsnce Farm Revised July 2007 Project Address 1.304 rases Ave Da4e 2/7%2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code I Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Mi n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flueldraft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans Ml yes 1412.2 Deadband control Indicate 5 degree deadband minimum Mi n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 dill. day types Mi a . 1412.4.1 Dampers Indicate damper location and auto, controls & max. leakage a. 1412.4.2 Optimum Start Indicate optimum start controls a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule a. 1412.6 Combustion htg. Indicate modulating or staged control a. 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas n. a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule mi 1413 Air economizers yes 14131 Air Econo Operation Indicate 100% capability on schedule a • 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb a. 14132 Water Econo Doc Indicate clg load & water econoe & clg tower performance a. 1413.3 Integrated operation Indicate capability for partial cooling a. 1413.4 Humidification Indicate direct evap or fog atomization wl air economizer 1414 Ducting systems no 1414.1 Duct sealing Indicate seating necessary a. 1414.2 Duct insulation Indicate R -value of insulation on duct . a. 1415.1 Piping insulation Indicate R -value of insulation on piping Completion Requirements a . 1416.2.1 Commissioning Provide commissioning plan a. 1416.2.2 -3 Sys. Bal & Func.Test Indicate air and water system balancing & functional testing a • 1416. 2.4 Commissioning Indicate O &M manuals, record drawings, staff training yes 1 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report M-1 n.a. 1 1434 ISeparate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATEV POOLS ec Ions 1440 Service water htg. a. 1441 Elec. water heater Indicate R -10 insulation under tank a . 1442 Shut -off controls indicate automatic shut -off a. 1443 Pipe Insulation Indicate R -value of insulation on piping . a. 1452 Heat Pump COP Indicate minimum COP of 4.0 a. 1452 Heater Efficiency Indicate pool heater efficiency a . 1453 Pool heater controls Indicate switch and 65 degree control a. 1454 Pool covers Indicate vapor retardant cover no 1454 1 Pools 30+ degrees Indicate R -12 pool cover 2006 State Nonresidential Energy Cade Compbonde Fo£n4 State Nonresidential Energv Code Compliance f=orm Revised .luty 2007 Project Info Project Address 1304 Yela Ave Date 2/7/2008 building A For Building Dept. Use Relm We Applicant Name: sound Beating i A/C Inc Applicant Address: 5526 184th St E Puyallup Ma Applicant Phone: 253 - 875 -3356 Project Description roof top unit and duct for 2,1741 sq ft T.I. Briefly describe mechanical system type and features. 0 Includes Plans (Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Q simple System 0 Complex System 0 Systems Analysis Compliance Option (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple 8 complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Coolin g Equipment Schedule Equip. IO Brand Name' Model No.' Capacity Btulh Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location RTU 1 YORE Iis06omioP -- - 59 H5H 2000 .YES 13.4 SEER ROOF Heatin g Equipment Schedule Equip- ID Brand Name' Model No.' Capacity Btuih Total CFM OSA cfm or Econo? input Btuh Output Btuh E ffiCiency s NoTONE QTWR116 110 0.50 LOCAL SWITCH TOILET ROODS Fan E ui ment Schedule Equip. ID Brand Name' Model No.' CFM Sp' HP /BHP Flow Controt5 Location of Service Er 1 -2 NoTONE QTWR116 110 0.50 LOCAL SWITCH TOILET ROODS 'If available. z As tested according to Table 14 -1A through 14 -1 G. 3 If required. ° COP. HSPF, Combustion Efficiency, orAFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). RECEIVED 2006 Washington State Nonresidential Energy Code Compliance Form d i System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: Constant vol? Split system? J Air cooled? Packaged sys? 11 <20,000 Btuh? 61 Economizer included? If Heating Only: <5000 cfm? ❑ <70% outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. START <70% OSA No <- 84,000 Btuh? I Ca '[u moors <20,000 N f tub? �utdoor , Yes Deference No Section 1423 <240,000 7 or 10°1 Y Simple System Yes <54,000 Use Complex Systems (section 1430) Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems Complex Systems requirements are applicable to this project. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist 2 O179 Weahingtvn State Now"denbal. Energy Code Compliance Forms Revised July 2007 ProjactAddress 1344 Ye1m Ave Date 2/7/'2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Cottle I Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401.1424) 1411 Equipment performance . a . 1411.4 Pkg. elec. htg.& clg. List treat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M1 n.a. 1411.1 Combustion Mg. Indicate intermittent ignition, flueldraft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans 141 yes 1412.2 Headband control Indicate 5 degree deadband minimum MI n. a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 dill. day types M-1 yes 1412.4,1 Dampers Indicate damper location and auto. controls & max. leakage rs1: a. 1412.4.2 Optimum Start Indicate optimum start controls a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule . a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans Ki 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas . a . 1422 Thermostat interlock indicate thermostat interlock on plans yea 1423 Economizers Equipment schedule M1 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule M1 yes 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 lHumidification Indicate direct evap or Fog atomization wl air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary M-1 yes 1414.2 Duct insulation Indicate R -value of insulation on duct M1 a . 1415.1 - - - Piping insulation Indicate R -value of insulation on piping Completion Requirements - Yes 1416.2.1 Commissioning Provide commissioning plan M1 yes 1416.21-3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing M1 yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training yes 1416.2.5 Gomm. Report Indicate requirements for prelim. & final commissioning report n. A. 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form linputJoutput, Completed and attached. Equipment schedule with types. efficiency. cfm, hp. economizer SERVICE WATER HEATING AN[) HEATEI) POOLS (Sections 1440 Service water htg. a. 1441 Elec, water heater Indicate R -10 insulation under tank a • 1442 Shut -off controls Indicate automatic shut -off a. 1443 Pipe Insulation Indicate R -value of insulation on piping a • 1452 Heat Pump COP Indicate minimum COP of 4.0 . a . 1452 Heater Efficiency Indicate pool heater efficiency a • 1453 Pool heater controls Indicate switch and 65 degree control a. 1454 Pool covers Indicate vapor retardant cover a. 1454 Pools 90+ degrees Indicate R -12 pool cover