Loading...
08-0004 Hydralic Calcs.December 31, 2007 Mr. Gary Carlson Building Official City of Yelm P.O. Box 479 Yelm, WA 98597 TOWNZEN & ASSOCIATES FIRE & BUILDING CODE SOLUTIONS RE: Fire Sprinkler Creek Street Plaza Building A Dear Gary: qqµ., JA44 The project listed above is approved for release of the permit; with no red line comments noted on the plans. If you have any questions, please give me a call. Sincerely, Townzen & Associates es ownzen, FPS President 410 11th AVE SE, SUITE 202 * OLYMPIA, WA 98501 * TEL: 360- 754 -2335 * FAX: 360- 754 -7722 www.townzen-consulting.com 5F5 SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East Tacoma, Washington 98424 (253) 926 -1880 FAX (253) 926 -2350 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME CREEK STREET PLAZA BUILDING A JOB NO. TC7040 DATE 11/27/07 ADDRESS 1304 YELM AVE. E. BY JAMES NULL YELM, WA. 98597 SYSTEM DESIGNATION: WET SYSTEM HAZARD DESCRIPTION: FUTURE SHOPS HAZARD CLASS PER NFPA 13: ORDINARY GROUP 2 SPECIFIC RULING: RULING MADE BY: OF DENSITY: .20 GPM OVER THE MOST HYDRAULICALLY REMOTE 1036 SQ. FT. (16' -0.5" ROOF) ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: INSIDE HOSE GPM OUTSIDE HOSE 250 GPM CITY CONNECTION IN -RACK SPRINKLER DEMAND GPM SYSTEM TYPE: WET TOTAL NUMBER OF SPRINKLERS THIS SYSTEM 180 "C" FACTOR OVERHEAD : 120 "C" FACTOR UNDERGROUND: 140 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: 121.50 SQUARE FEET SPRINKLER MANUFACTURER: RELIABLE MODEL: F1 FR TEMPERATURE: 200 ° F K- FACTOR: 8.0 ORIFICE SIZE: 17/32" WATER SUPPLY: STATIC 50 PSI RESIDUAL 40 PSI FLOW 1100 GPM ELEVATION OF TEST: DATE OF TEST: 2004 DATA PROVIDED BY: CITY OF YELM LOCATION OF TEST: 106T" STREET AND NE CREEK STREET BASE OF RISER DEMAND 266.59 GPM REQUIRED AT 32.35PS1 (INCLUDING 0 GPM FOR HOSE STREAMS) SUMMARY 516.59 GPM REQUIRED AT 38.71 PSI AT CONNECTION TO TEST HYDRANT (INCLUDING 250 GPM FOR TOTAL HOSE STREAMS) �,,,•C � s o �w �L nre a 3604 r - ell SWIM CERTIFICATE OF COMPETENCY STAMP U) a_ Z W W U) W rr a_ VOLUME IN GPM X 110 WATER SUPPLY DATA JOB NAME CREEK STREET PLAZA S STATIC 50 PSI ADDRESS 1304 YELM AVE. E. YELM, WA. 98597 RESIDUAL 40 PSI JOB NO. TC7040 90 SMITH FIRE SYSTEMS, INC. FLOWING 1100 GPM SYSTEM /AREA TREE ' 1 S YSTEM DEMAND @ BASE OF RISER t 266.59GP M A S 32.3 PS I ( INCLUDES 0 GPM FORHOSE STREAMS ) ; I 1 T -- - SYSTEM DEMAND @ CITY CONNECTION — - i- 2 E 516.59 GPM AT 38.71 PSI 70+ . (IN CLUDES 250 GPM TOTAL HOSE STREAMS) t , 4-. T T t gn i Tr - — r i f ' j 0 1 2 3 4 5 6 7 8 9 10 VOLUME IN GPM X 110 SUBMITTAL SERIAL NO:2244HY1 CREEK STREET PLAZA TREE .20/1036 TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLAI FLOW TEST RESULTS Water Supply STATIC 50.00 PSI RESIDUAL 40.00 PSI @ 1100.00 GPM CITY PRESSURE AVAILABLE AT 516.6 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K- FACTOR PRESSURE - -- 301 - - -- 25.75 - - -- 24.30 -- - - - - -- -- 8.00 - - - - -- 10.36 302 25.05 24.30 8.00 9.81 303 24.59 24.30 8.00 9.44 304 24.36 24.30 8.00 9.27 305 24.30 24.30 8.00 9.23 306 28.74 24.30 8.00 12.90 307 28.50 24.30 8.00" 12.69 308 28.42 24.30 8.007 12.62 309 28.42 24.30 8.00 12.62 310 28.47 24.30 8.00 12.67 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 3 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 10 TO 21 47.53 PSI 266.59 GPM 250.00 GPM 516.59 GPM 38.71 PSI 0.00 PSI 14.84 FPS 11 -26 -2007 PAGE 1 SUBMITTAL SERIAL NO:2244HY1 11 -26 -2007 PAGE 2 CREEK STREET PLAZA TREE .20/1036 TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLAI Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI /Ft PSI 304 305 2.185 L 9.00 C =120 PT 9.23 (305) Q 24.30 F =O F 0.00 PE 0.00 BN T 9.00 0.0052 PF 0.05 303 304DQ 24.36 2.185 L 9.00 C =120 PT 9.28 (304) Q 48.66 F =0 F 0.00 PE 0.00 BN T 9.00 0.0189 PF 0.17 302 303DQ 24.59 2.185 L 9.00 C =120 PT 9.45 (303) Q 73.25 F =0 F 0.00 PE 0.00 BN T 9.00 0.0403 PF 0.36 301 302DQ 25.05 2.185 L 8.00 C =120 PT 9.81 (302) Q 98.30 F =0 F 0.00 PE 0.00 BN T 8.00 0.0695 PF 0.56 34 301DQ 25.75 2.185 L 39.75 C =120 PT 10.37 (301) Q 124.05 F =0 F 0.00 PE 0.00 BN T 39.75 0.1068 PF 4.25 PT 14.62 ( 34) --------------- 308 309 - -- 2.185 L 9.00 C =120 PT 12.62 (309) Q 1.89 F =O F 0.00 PE 0.00 BL T 9.00 0.0000 PF 0.00 307 308DQ 28.42 2.185 L 9.00 C =120 PT 12.62 (308) Q 30.31 F =0 F 0.00 PE 0.00 BL T 9.00 0.0079 PF 0.07 306 307DQ 28.50 2.185 L 8.00 C =120 PT 12.69 (307) Q 58.80 F =0 F 0.00 PE 0.00 BL T 8.00 0.0268 PF 0.21 35 306DQ 28.74 2.185 L 39.75 C =120 PT 12.90 (306) Q 87.54 F =0 F 0.00 PE 0.00 BL T 39.75 0.0561 PF 2.23 207 35DQ -61.49 2.185 L 132.25 C =120 PT 15.13 ( 35) Q 26.05 F =T F 14.00 PE 0.00 BL1 T 146.25 0.0060 PF 0.88 208 207 2.185 L 9.00 C =120 PT 16.01 (207) Q 26.05 F =0 F 0.00 PE 0.00 BL1 T i 9.00 0.0060 PF 0.05 SUBMITTAL SERIAL NO:2244HY1 11 -26 -2007 PAGE 3 CREEK STREET PLAZA TREE .20/1036 TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLAI Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI /Ft PSI 209 208 2.185 L 9.00 C =120 PT 16.06 (208) Q 26.05 F =0 F 0.00 PE 0.00 BL1 T 9.00 0.0060 PF 0.05 210 209 2.185 L 6.00 C =120 PT 16.11 (209) Q 26.05 F =0 F 0.00 PE 0.00 BL1 T 6.00 0.0060 PF 0.04 211 210 2.185 L 7.50 C =120 PT 16.15 (210) Q 26.05 F =0 F 0.00 PE 0.00 BL1 T 7.50 0.0060 PF 0.05 212 211 2.185 L 7.50 C =120 PT 16.20 (211) Q 26.05 F =0 F 0.00 PE 0.00 BL1 T 7.50 0.0060 PF 0.05 45 212 2.185 L 2.08 C =120 PT 16.25 (212) Q 26.05 F =0 F 0.00 PE 0.00 BL1 T 2.08 0.0060 PF 0.01 PT 16.26 ( 45) --------------- 201 34 - -- 2.185 L 132.25 C =120 PT 14.61 ( 34) Q 33.69 F =T F 14.00 PE 0.00 BL1 T 146.25 0.0096 PF 1.40 202 201 2.185 L 9.00 C =120 PT 16.01 (201) Q 33.69 F =0 F 0.00 PE 0.00 BL1 9.00 0.0096 PF 0.09 203 202 2.185 L 9.00 C =120 PT 16.10 (202) Q 33.69 F =0 F 0.00 PE 0.00 BL1 T 9.00 0.0096 PF 0.09 204 203 2.185 L 6.00 C =120 PT 16.19 (203) Q 33.69 F =0 F 0.00 PE 0.00 BL1 T 6.00 0.0096 PF 0.06 205 204 2.185 L 7.50 C =120 PT 16.25 (204) Q 33.69 F =0 F 0.00 PE 0.00 BL1 T 7.50 0.0096 PF 0.07 206 205 2.185 L 7.50 C =120 PT 16.32 (205) Q 33.69 F =0 F 0.00 PE 0.00 BL1 T 7.50 0.0096 PF 0.07 SUBMITTAL SERIAL NO:2244HY1 11 -26 -2007 PAGE 4 CREEK STREET PLAZA TREE .20/1036 TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLAI Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI /Ft PSI 44 206 2.185 L 2.08 C =120 PT 16.39 (206) Q 33.69 F =0 F 0.00 PE 0.00 BL1 T 2.08 0.0096 PF 0.02 PT 16.41 ( 44) --------------- 310 309 - -- 2.185 L 7.96 C =120 PT 12.62 (309) Q 26.53 F =0 F 0.00 PE 0.00 BL T 7.96 0.0062 PF 0.05 60 310DQ 28.47 2.185 L 1.10 C =120 PT 12.67 (310) Q 55.00 F =E F 7.00 PE 0.00 BL T 8.10 0.0237 PF 0.19 61 60 2.185 L 4.50 C =120 PT 12.86 ( 60) Q 55.00 F =T F 14.00 PE 1.95 BL T 18.50 0.0237 PF 0.44 59 61 2.185 L 3.83 C =120 PT 15.25 ( 61) Q 55.00 F =E F 7.00 PE 0.00 BL T 10.83 0.0237 PF 0.26 58 59 2.185 L 2.92 C =120 PT 15.51 ( 59) Q 55.00 F =E F 7.00 PE 0.00 BL T 9.92 0.0237 PF 0.24 57 58 2.185 L 8.10 C =120 PT 15.75 ( 58) Q 55.00 F =0 F 0.00 PE 0.00 BL T 8.10 0.0237 PF 0.19 56 57 2.185 L 9.50 C =120 PT 15.94 ( 57) Q 55.00 F =0 F 0.00 PE 0.00 BL T 9.50 0.0237 PF 0.23 55 56 2.185 L 9.50 C =120 PT 16.17 ( 56) Q 55.00 F =0 F 0.00 PE 0.00 BL T 9.50 0.0237 PF 0.23 36 55 2.185 L 48.58 C =120 PT 16.40 ( 55) Q 55.00 F =2E F 14.00 PE -0.43 BL T 62.58 0.0237 PF 1.48 26 36DQ -11.47 2.185 L 3.00 C =120 PT 17.45 ( 36) Q 43.53 F =2T F 28.00 PE -1.30 BL T 31.00 0.0154 PF 0.48 SUBMITTAL SERIAL NO:2244HY1 CREEK STREET PLAZA TREE .20/1036 TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLAI Location Flow Pipe Fittings in Size & From To GPM IN Devices 25 26 2.709 Q 43.53 F =0 CM ------------------ 45 36 Friction 2.185 Q 11.47 F =9E Ft BL1 44 45DQ 26.05 2.185 C =120 PT Q 37.52 F F =0 PE 0.00 CM2 T 43 44DQ 33.69 2.185 Q 71.21 PT F =0 25) L 189.41 CM2 PT 42 43DQ -17.45 2.185 PE Q 53.75 T F =0 0.0013 PF 0.33 CM2 L 52 42 PT 2.185 45) F Q 53.75 PE F =2EE T 13.50 BL1 PF 41 52DQ -20.24 2.185 C =120 PT Q 33.52 F F =T /T PE 0.00 BL1 T 31 41 PF 2.185 L Q 33.52 PT F =E,T 43) F 0.00 BL1 PE 21 31 T 2.185 0.0227 PF Q 33.52 L F =2T C =120 PT 17.24 ( RN1 F ------------------ 33 43 PE 2.185 T Q 17.45 PF F =T L 6.50 BL1 PT 23 33 F 2.185 PE Q 17.45 T F =2T' 0.0095 PF 0.33 RN1 L 11 -26 -2007 PAGE 5 Equiv Friction Pressure Length Loss Summary Ft PSI /Ft PSI 5.58 C =120 PT 16.63 ( 26) F 0.00 PE 0.00 T 5.58 0.0054 PF 0.03 PT 16.66 ( 25) L 189.41 C =120 PT 17.43 ( 36) F 63.00 PE -1.52 T 252.41 0.0013 PF 0.33 L 13.50 C =120 PT 16.24 ( 45) F 0.00 PE 0.00 T 13.50 0.0117 PF 0.16 L 13.50 C =120 PT 16.40 ( 44) F 0.00 PE 0.00 T 13.50 0.0383 PF 0.52 L 14.21 C =120 PT 16.92 ( 43) F 0.00 PE 0.00 T 14.21 0.0227 PF 0.32 L 41.00 C =120 PT 17.24 ( 42) F 6.00 PE 0.00 T 47.00 0.0227 PF 1.07 L 6.50 C =120 PT 18.31 ( 52) F 28.00 PE 0.00 T 34.50 0.0095 PF 0.33 L 136.67 C =120 PT 18.64 ( 41) F 21.00 PE 0.00 T 157.67 0.0095 PF 1.50 L 1.50 C =120 PT 20.14 ( 31) F 28.00 PE 0.65 T 29.50 0.0095 PF 0.28 PT 21.07 ( 21) L 173.33 C =120 PT 16.92 ( 43) F 14.00 PE 0.00 T 187.33 0.0028 PF 0.52 L 1.50 C =120 PT 17.44 ( 33) F 28.00 PE 0.65 T 29.50 0.0028 PF 0.08 PT 18.17 ( 23) SUBMITTAL SERIAL NO:2244HY1 11 -26 -2007 PAGE 6 CREEK STREET PLAZA TREE .20/1036 TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLAI Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI /Ft PSI ------------------ 32 52 2.185 L 130.67 C =120 PT 18.31 ( 52) Q 20.24 F =0 F 0.00 PE 0.00 BL1 T 130.67 0.0037 PF 0.48 22 32 2.185 L 1.50 C =120 PT 18.79 ( 32) Q 20.24 F =2T F 28.00 PE 0.65 RN1 T 29.50 0.0037 PF 0.11 PT 19.55 ( 22) ------------------ 25 35 2.185 L 1.50 C =120 PT 15.13 ( 35) Q 61.49 F =2T F 28.00 PE 0.65 RN1 T 29.50 0.0292 PF 0.86 24 25DQ 43.53 2.709 L 13.50 C =120 PT 16.64 ( 25) Q 105.02 F =0 F 0.00 PE 0.00 CM1 T 13.50 0.0276 PF 0.37 PT 17.01 ( 24) ------------------ 24 34 2.185 L 1.50 C =120 PT 14.61 ( 34) Q 90.37 F =2T F 28.00 PE 0.65 RN1 T 29.50 0.0594 PF 1.75 23 24DQ 105.02 2.709 L 13.50 C =120 PT 17.01 ( 24) Q 195.38 F =0 F 0.00 PE 0.00 CM1 T 13.50 0.0869 PF 1.17 22 23DQ 17.45 2.709 L 13.50 C =120 PT 18.18 ( 23) Q 212.84 F =0 F 0.00 PE 0.00 CM1 - 13.50 0.1018 PF 1.37 21 22DQ 20.24 2.709 L 12.50 C =120 PT 19.55 ( 22) Q 233.07 F =0 F 0.00 PE 0.00 CM1 T 12.50 0.1204 PF 1.50 PT 21.05 ( 21) ------------------ 4 3 8.265 L 473.00 C =140 PT 38.58 ( 3) Q 168.99 F= 2EE,2GV,2T F 142.00 PE 0.00 LU T 615.00 0.0002 PF 0.12 1 4 10.275 L 15.00 C =140 PT 38.70 ( 4) Q 168.99 F =0 F 0.00 PE 0.00 LU T 15.00 0.0001 PF 0.00 PT 38.70 ( 1) SUBMITTAL SERIAL NO:2244HY1 11 -26 -2007 PAGE 7 CREEK STREET PLAZA TREE .20/1036 TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLAI Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI /Ft PSI ------------------ 2 3 8.265 L 43.00 C =140 PT 38.58 ( 3) Q 347.60 F =T,GV F 58.00 PE 0.00 LU T 101.00 0.0008 PF 0.08 1 2 10.275 L 180.00 C =140 PT 38.66 ( 2) Q 347.60 F =0 F 0.00 PE 0.00 LU T 180.00 0.0003 PF 0.05 PT 38.71 ( 1) ------------------ 10 21 2.709 L 13.71 C =120 PT 21.07 ( 21) Q 266.59 F =2E F 20.00 PE 0.00 FM1 T 33.71 0.1544 PF 5.20 8 10 3.320 L 12.10 C =120 PT 26.27 ( 10) Q 266.59 F =0 F 0.00 PE 5.24 FR T 12.10 0.0573 PF 0.69 7 8 3.320 L 0.29 C =120 PT 32.20 ( 8) Q 266.59 F =0 F 0.00 PE 0.13 FR T 0.29 0.0573 PF 0.02 6 7 6.155 L 202.00 C =140 PT 32.35 ( 7) Q 266.59 F =4EE,E F 53.00 PE 2.60 UN T 255.00 0.0021 PF 0.54 5 6 6.000 L 4.00 C =140 PT 35.49 ( 6) Q 266.59 F =DD1 F 0.00 PE 0.00 UN T 4.00 0.0024 PF 0.01 6" WILKINS MODEL 350DA DOUBLE DETECTOR ASSEMBLY 2.93 3 5 6.155 L 18.00 C =140 PT 38.43 ( 5) Q 266.59 F =GV,T F 47.00 PE 0.00 UN T 65.00 0.0021 PF 0.14 PT 35.64 ( 3) ------------------ 0 1 10.275 L 0.01 C =140 PT 38.71 ( 1) Q 516.59 F =Q 0.00 PE 0.00 UN T 0.01 0.0006 PF 0.00 PT 38.71 ( 0) SMITH FIRE SYSTEMS, INC. JOB NO. TC7040 CREEK STREET PLAZA AUXILIARY CALCULATED AREA # 1 AUXILIARY HYDRAULIC CALCULATION DESIGN DENSITY: .20 GPM / 1036 SQ. FT. SYSTEM DEMAND AT BASE OF RISER 246.58 GPM AT 27.17PS1 U) d Z W Cc U) U) W VOLUME IN GPM X 110 WATER SUPPLY DATA JOB NAME CREEK STREET PLAZA S STATIC 50 PSI ADDRESS 1304 YELM AVE. E. YELM, WA. 98597 RESIDUAL 40 PSI JOB NO. TC7040 SMITH FIRE SYSTEMS, INC. FLOWING 1 100 GPM SYSTEM /AREA GRID 90 1 SYSTEM DEMAND @ BASE OF RISER 246 58 GPM AT 27.17 PSI � f I ( INCLUDES 0 GPM FOR HOSE STREAMS ) ... 2. SYSTEM DEMAND @ CITY CONNECTION 496.58 GPM AT 33.53 PSI ' I ' (INCLUDES 250 GPM TOTAL HOSE STREAMS) Rn I r -- tc 4 I HI I I L I- i I I , T I I - 1. I ... I I r • I 0 1 2 3 4 5 6 7 8 9 10 VOLUME IN GPM X 110 AUXILIARY SUBMITTAL SERIAL NO:2244HY1 CREEK STREET PLAZA GRID .20/1036 TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLA2 FLOW TEST RESULTS Water Supply STATIC 50.00 PSI RESIDUAL 40.00 PSI @ 1100.00 GPM CITY PRESSURE AVAILABLE AT 496.6 GPM TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 2 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 10 TO 21 47.70 PSI 246.58 GPM 250.00 GPM 496.58 GPM 33.53 PSI 0.00 PSI 13.73 FPS 11 -26 -2007 PAGE 1 SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K- FACTOR PRESSURE - -- 201 - - -- 25.02 - - -- 24.30 -- - - - - -- 8.00 -- - - - - -- 9.78 202 24.96 24.30 8.00 9.73 203 24.96 24.30 8.00 9.73 204 25.00 21.17 8.00 9.77 207 24.38 24.30 8.00 9.29 208 24.30 24.30 8.00 9.23 209 24.30 24.30 8.00 9.23 210 24.33 21.17 8.00 9.25 211 24.49 21.17 8.00 9.37 212 24.84 21.17 8.00 9.64 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 2 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 10 TO 21 47.70 PSI 246.58 GPM 250.00 GPM 496.58 GPM 33.53 PSI 0.00 PSI 13.73 FPS 11 -26 -2007 PAGE 1 AUXILIARY SUBMITTAL SERIAL NO:2244HY1 11 -26 -2007 PAGE 2 CREEK STREET PLAZA GRID .20/1036 TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLA2 FROM TO FLOW LENGTH FITTING DIAM TYPE PSI /Ft S -LOSS PRESSURES --------------- 210 209 - 20.48 - - -- 6.00 0.0 2.185 BL1 0.004 0.00 9.25 9.23 211 210 44.81 7.50 0.0 2.185 BL1 0.016 0.00 9.37 9.25 212 211 69.29 7.50 0.0 2.185 BL1 0.036 0.00 9.64 9.37 45 212 94.14 2.08 0.0 2.185 BL1 0.064 0.00 9.77 9.64 --------------- 208 209 - 3.82 - - -- 9.00 0.0 2.185 BL1 0.000 0.00 9.23 9.23 207 208 28.13 9.00 0.0 2.185 BL1 0.007 0.00 9.29 9.23 35 207 52.51 132.25 14.0 2.185 BL1 0.022 0.00 12.48 9.29 --------------- 203 202 - 0.66 - - -- 9.00 0.0 2.185 BL1 0.000 0.00 9.73 9.73 204 203 25.62 6.00 0.0 2.185 BL1 0.006 0.00 9.76 9.73 205 204 50.62 7.50 0.0 2.185 BL1 0.020 0.00 9.91 9.76 206 205 50.62 7.50 0.0 2.185 BL1 0.020 0.00 10.06 9.91 44 206 50.62 2.08 0.0 2.185 BL1 0.020 0.00 10.10 10.06 --------------- 201 202 - 24.30 - - -- 9.00 0.0 2.185 BL1 0.005 0.00 9.78 9.73 34 201 49.31 132.25 14.0 2.185 BL1 0.019 0.00 12.62 9.78 24 34 49.31 1.50 28.0 2.185 RN1 0.019 0.65 13.84 12.62 --------------- 306 35 - 10.15 - - -- 39.75 0.0 2.185 BL 0.001 0.00 12.51 12.47 307 306 10.15 8.00 14.0 2.185 BL 0.001 0.00 12.53 12.51 308 307 10.15 9.00 14.0 2.185 BL 0.001 0.00 12.55 12.53 309 308 10.15 9.00 14.0 2.185 BL 0.001 0.00 12.57 12.55 310 309 10.15 7.96 0.0 2.185 BL 0.001 0.00 12.58 12.57 60 310 10.15 1.10 7.0 2.185 BL 0.001 0.00 12.59 12.58 61 60 10.15 4.50 14.0 2.15 BL 0.001 1.95 14.56 12.59 59 61 10.15 3.83 7.0 2.185 BL 0.001 0.00 14.57 14.56 58 59 10.15 2.92 7.0 2.185 BL 0.001 0.00 14.58 14.57 57 58 10.15 8.10 0.0 2.185 BL 0.001 0.00 14.59 14.58 56 57 10.15 9.50 0.0 2.185 BL 0.001 0.00 14.60 14.59 55 56 10.15 9.50 0.0 2.185 BL 0.001 0.00 14.61 14.60 36 55 10.15 48.58 14.0 2.185 BL 0.001 -0.43 14.24 14.61 -------------------- 36 45 37.58 189.41 63.0 2.185 BL 0.012 1.52 14.25 9.78 26 36 47.74 3.00 28.0 2.185 RN 0.018 -1.30 13.52 14.25 25 26 47.74 5.58 0.0 2.709 CM 0.006 0.00 13.56 13.52 -------------------- 44 45 56.56 13.50 0.0 2.185 CM2 0.025 0.00 10.12 9.78 43 44 107.17 13.50 0.0 2.185 CM2 0.082 0.00 11.22 10.12 42 43 69.14 14.21 0.0 2.185 CM2 0.036 0.00 11.73 11.22 52 42 69.14 41.00 6.0 2.185 BL1 0.036 0.00 13.43 11.73 41 52 37.54 6.50 28.0 2.185 BL1 0.012 0.00 13.83 13.43 31 41 37.54 136.67 21.0 2.185 BL1 0.012 0.00 15.67 13.83 21 31 37.54 1.50 28.0 2.185 RN1 0.012 0.65 16.67 15.67 -------------------- 33 43 38.03 173.33 14.0 2.185 BL1 0.012 0.00 13.46 11.21 23 33 38.03 1.50 28.0 2.185 RN1 0.012 0.65 14.46 13.46 AUXILIARY SUBMITTAL SERIAL NO:2244HY1 CREEK STREET PLAZA GRID .20/1036 TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLA2 11 -26 -2007 PAGE 3 FROM TO FLOW LENGTH FITTING DIAM TYPE PSI /Ft S -LOSS -------------------- 32 52 31.60 130.67 0.0 2.185 BL1 0.009 0.00 22 32 31.60 1.50 28.0 2.185 RN1 0.009 0.65 -------------------- 25 35 42.35 1.50 28.0 2.185 RN1 0.015 0.65 24 25 90.09 13.50 0.0 2.709 CM1 0.021 0.00 23 24 139.40 13.50 0.0 2.709 CMl 0.047 0.00 22 23 177.43 13.50 0.0 2.709 CM1 0.073 0.00 21 22 209.04 12.50 0.0 2.709 CM1 0.098 0.00 -------------------- 4 3 110.44 473.00 107.0 8.265 LU 0.000 0.00 1 4 110.44 15.00 0.0 10.275 LU 0.000 0.00 -------------------- 2 3 136.14 43.00 58.0 8.265 LU 0.000 0.00 1 2 386.14 180.00 0.0 10.275 LU 0.000 0.00 -------------------- 10 21 246.58 13.71 20.0 2.709 FM1 0.134 0.00 8 10 246.58 12.10 0.0 3.320 FR 0.050 5.24 7 8 246.58 0.29 0.0 3.320 FR 0.050 0.13 6 7 246.58 202.00 40.0 6.155 UN 0.002 2.60 5 6 246.58 4.00 0.0 6.000 UN 0.003 0.00 6" WILKINS MODEL 350DA DOUBLE DETECTOR ASSEMBLY 3 5 246.58 18.00 35.0 6.155 UN 0.002 0.00 -------------------- 0 1 496.58 0.01 0.0 10.275 UN 0.001 0.00 PRESSURES 14.54 13.43 15.44 14.54 13.55 12.47 13.83 13.55 14.46 13.83 15.44 14.46 16.67 15.44 33.51 33.45 33.51 33.51 33.46 33.45 33.51 33.46 21.19 16.68 27.03 21.19 27.17 27.03 30.37 27.17 30.38 30.37 2.95 33.46 33.33 33.53 33.53 SMITH FIRE SYSTEMS, INC. JOB NO. TC7040 CREEK STREET PLAZA AUXILIARY CALCULATED AREA # 2 AUXILIARY HYDRAULIC CALCULATION DESIGN DENSITY: .20 GPM / 7 SPRINKLERS IN CANOPY SYSTEM DEMAND AT BASE OF RISER 106.85 GPM AT 17.44 PSI U) a_ z W U) w cr- CL VOLUME IN GPM X 110 WATER SUPPLY DATA JOB NAME CREEK STREET PLAZA SSTATIC 50 PSI ADDRESS 1304 YELM AVE. E. YELM, WA. 98597 RESIDUAL 40 PSI JOB NO. TC7040 90 SMITH FIRE SYSTEMS, INC. FLOWING 1100 GPM SYSTEM /AREA CANOPY .:1 ::: is � • I I 1 SYSTEM DEMAND @ BASE OF RISER } —— — 106.85 GPM AT 17.44 PSI - I _• ( INCLUDES 0 GPM FOR HOSE STREAMS ) - 2 SYSTEM DEMAND (p CITY CONNECTION - - - 356.85 GPM AT 24.77 PSI ( INCLUDES 250 GPM TOTAL HOSE STREAMS) I - - I {_.• - - - - -- -�•- -• : -.I .l :.. -. 1 ! - -�.. T. I'I :... -_ 1 - -_ - i I 1. I `.hViJll..:. _ I ... _. : ... ..._ 4 I. oo . ... i i . . . ..... 1 , -. in t 0 1 2 3 4 5 6 7 8 9 10 VOLUME IN GPM X 110 AUXILIARY SUBMITTAL SERIAL NO:2244HY1 11 -26 -2007 PAGE 1 CREEK STREET PLAZA CANOPY .20/7 HEADS TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLA2 FLOW TEST RESULTS Water Supply STATIC 50.00 PSI RESIDUAL 40.00 PSI @ 1100.00 GPM CITY PRESSURE AVAILABLE AT 356.9 GPM 48.75 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K- FACTOR PRESSURE - -- - - -- - - -- -- - - - - -- -- - - - - -- 401 15.55 15.20 5.60 7.71 402 15.35 15.20 5.60 7.51 403 15.24 15.20 5.60 7.40 404 15.20 15.20 5.60 7.37 405 15.19 14.82 5.60 7.36 406 15.17 14.82 5.60 7.34 407 15.16 14.82 5.60 7.33 TOTAL WATER REQUIRED FOR SYSTEM 106.85 GPM OUTFLOWS AT 3 250.00 GPM TOTAL WATER REQUIREMENT 356.85 GPM PRESSURE REQUIRED AT 0 24.77 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.00 PSI MAXIMUM VELOCITY FROM 26 TO 36 6.14 FPS AUXILIARY SUBMITTAL SERIAL NO:2244HY1 CREEK STREET PLAZA CANOPY .20/7 HEADS TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLA2 FROM TO 58 404 63 407 62 63 62 406 61 62 59 405 57 403 56 402 55 401 61 59 60 61 310 60 309 310 308 309 307 308 306 307 35 306 207 35 208 207 209 208 210 209 211 210 212 211 45 212 44 45 206 44 205 206 204 205 203 204 202 203 201 202 34 201 24 34 58 59 57 58 56 57 55 56 36 55 43 44 FLOW LENGTH FITTING 15.20 1.92 5.0 15.16 1.92 5.0 15.16 7.50 0.0 15.17 1.92 5.0 30.33 3.67 0.0 15.19 1.92 5.0 15.24 1.92 5.0 15.35 1.92 5.0 15.55 1.92 5.0 7.71 3.38 7.0 38.04 4.50 14.0 38.04 1.12 0.0 38.04 7.96 0.0 38.04 9.00 0.0 38.04 9.00 0.0 38.04 8.00 0.0 38.04 39.75 7.0 38.04 132.25 0.0 38.04 9.00 0.0 38.04 9.00 0.0 38.04 6.00 0.0 38.04 7.50 0.0 38.04 7.50 0.0 38.04 2.08 14.0 35.07 13.50 0.0 4.57 2.08 14.0 4.57 7.50 0.0 4.57 7.50 0.0 4.57 6.00 0.0 4.57 9.00 0.0 4.57 9.00 0.0 4.57 132.25 0.0 4.57 1.50 28.0 7.49 2.92 7.0 22.69 8.10 0.0 37.93 9.50 0.0 53.27 9.50 0.0 68.82 48.58 14.0 30.50 13.50 0.0 11 -26 -2007 PAGE 2 DIAM TYPE PSI /Ft S -LOSS PRESSURES 1.049 AO 0.078 0.00 7.91 7.37 1.049 AO 0.078 0.00 7.87 7.33 2.185 BN 0.002 0.00 7.89 7.87 1.049 AO 0.078 0.00 7.88 7.34 2.185 BN 0.008 0.00 7.91 7.88 1.049 AO 0.078 0.00 7.90 7.36 1.049 AO 0.079 0.00 7.94 7.40 1.049 AO 0.080 0.00 8.06 7.51 1.049 AO 0.082 0.00 8.28 7.71 2.185 CM 0.001 0.00 7.91 7.90 2.185 BL 0.012 -1.95 6.18 7.91 2.185 BL 0.012 0.00 6.19 6.18 2.185 BL 0.012 0.00 6.29 6.19 2.185 BL 0.012 0.00 6.40 6.29 2.185 BL 0.012 0.00 6.51 6.40 2.185 BL 0.012 0.00 6.61 6.51 2.185 BL 0.012 0.00 7.17 6.61 2.185 BL1 0.012 0.00 8.76 7.17 2.185 BL1 0.012 0.00 8.87 8.76 2.185 BL1 0.012 0.00 8.98 8.87 2.185 BL1 0.012 0.00 9.05 8.98 2.185 BL1 0.012 0.00 9.14 9.05 2.185 BL1 0.012 0.00 9.23 9.14 2.185 BL1 0.012 0.00 9.42 9.23 2.185 CM2 0.010 0.00 9.56 9.42 2.185 BL1 0.000 0.00 9.56 9.56 2.185 BL1 0.000 0.00 9.56 9.56 2.185 BL1 0.000 0.00 9.56 9.56 2.185 BL1 0.000 0.00 9.56 9.56 2.185 BL1 0.000 0.00 9.56 9.56 2.185 BL1 0.000 0.00 9.56 9.56 2.185 BL1 0.000 0.00 9.59 9.56 2.185 RN1 0.000 0.65 10.25 9.59 2.185 BL 0.001 0.00 7.91 7.90 2.185 BL 0.005 0.00 7.95 7.91 2.185 BL 0.012 0.00 8.06 7.95 2.185 BL 0.022 0.00 8.27 8.06 2.185 BL 0.036 -0.43 10.09 8.27 2.185 CM2 0.008 0.00 9.66 9.55 AUXILIARY SUBMITTAL SERIAL NO:2244HY1 11 -26 -2007 PAGE 3 CREEK STREET PLAZA CANOPY .20/7 HEADS TC7040 ORDINARY GROUP 2 (MERCANTILE) CRKPLA2 FROM TO FLOW LENGTH FITTING DIAM TYPE PSI /Ft S -LOSS PRESSURES 42 43 22.35 14.21 0.0 2.185 CM2 0.004 0.00 9.72 9.66 52 42 22.35 41.00 6.0 2.185 BL1 0.004 0.00 9.93 9.72 41 52 13.68 6.50 28.0 2.185 BL1 0.002 0.00 9.99 9.93 31 41 13.68 136.67 21.0 2.185 BL1 0.002 0.00 10.27 9.99 21 31 13.68 1.50 28.0 2.185 RN1 0.002 0.65 10.97 10.27 -------------------- 36 45 2.97 189.41 63.0 2.185 BL 0.000 0.65 10.09 9.41 26 36 71.79 3.00 28.0 2.185 RN 0.039 -1.30 9.99 10.09 25 26 71.79 5.58 0.0 2.709 CM 0.014 0.00 10.07 9.99 24 25 71.79 13.50 0.0 2.709 CM1 0.014 0.00 10.25 10.07 23 24 76.36 13.50 0.0 2.709 CM1 0.015 0.00 10.46 10.25 -------------------- 33 43 8.14 173.33 14.0 2.185 BL1 0.001 0.00 9.79 9.66 23 33 8.14 1.50 28.0 2.185 RN1 0.001 0.65 10.46 9.79 22 23 84.50 13.50 0.0 2.709 CM1 0.018 0.00 10.71 10.46 -------------------- 32 52 8.67 130.67 0.0 2.185 BL1 0.001 0.00 10.03 9.93 22 32 8.67 1.50 28.0 2.185 RN1 0.001 0.65 10.70 10.03 21 22 93.17 12.50 0.0 2.709 CM1 0.022 0.00 10.98 10.70 4 3 116.85 473.00 142.0 8.265 LU 0.000 0.00 24.77 24.71 1 4 116.85 15.00 0.0 10.275 LU 0.000 0.00 24.77 24.77 -------------------- 2 3 240.00 43.00 58.0 8.265 LU 0.000 0.00 24.75 24.71 1 2 240.00 180.00 0.0 10.275 LU 0.000 0.00 24.77 24.75 -------------------- 10 21 106.85 13.71 20.0 2.709 FM1 0.029 0.00 11.94 10.98 8 10 106.85 12.10 0.0 3.320 FR 0.011 5.24 17.31 11.94 7 8 106.85 0.29 0.0 3.320 FR 0.011 0.13 17.44 17.31 6 7 106.85 202.00 53.0 6.155 UN 0.000 2.60 20.14 17.44 5 6 106.85 4.00 0.0 6.000 UN 0.000 0.00 20.14 20.14 6" WILKINS MODEL 350DA DOUBLE DETECTOR ASSEMBLY 4.54 3 5 106.85 18.00 47.0 6.155 UN 0.000 0.00 24.71 24.68 -------------------- 0 1 356.85 0.01 0.0 10.275 UN 0.000 0.00 24.77 24.77 _j 11mabi� Model F1 FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model F1 FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals 1. Listed by Underwriters Laboratories: Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (U LC) 3. Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) 5. NYC BS &A No. 587 -75 -SA 6. Meets MIL- S -901C and MIL -STD 167 -1 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258 -93 -E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV Patents: US Patent No. 6,374,920 Applies to Model F1 FR Vertical Sidewall Sprinklers. Product Description Reliable Models F1 FR and F1 FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1 FR and F1 FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR and F1 FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- Bulletin 136 Kiev 0 Model F1FR Model F1 FR Recessed Quick Response Sarinklers Upright Pendent Vertical Sidewall Conventional Horizontal Sidewall Recessed Pendent HSW 1 Deflector (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb; causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2 -8N or other applicable standards. Quick response sprinklers and standard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 DD N I ,s Upright Pendent Vertical Sidewall Conventional Horizontal Sidewall Recessed Pendent HSW 1 Deflector (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb; causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2 -8N or other applicable standards. Quick response sprinklers and standard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 DD N I Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench - Upright Pendent Conventional Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Factor Sprinkler Identification Sprinkler Type — Sprinkler Identification Sprinkler Approval I Number SIN Metric US Metric Height 9 Or anization g - - 5,6 80 2 2„ (56mm) 1,2,3,45,7,8 R3615 (20mrr) SSU SSP Standard - Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position ;' NPT (R'',,' 4,2 " (15mm) Standard Orifice with y' NPT (R);) Thread S 6 80 22" (56mm) 1,2,3 4 5,6,7 R3625t 83615 - - -- — " (20mm ) Large Orifice with,';" NPT (R' /.,)Thread 8.0 115 2.3" (58mm) 1,2,3,4,7,8 - - R3622t't R3612 "(17mm ) Small Orifice with,,-," NPT (R:,) Thread ' Z 60 1 22" (56mm) 1.2,8 R3623 "� R3613 (10mm) Small Orifice %dth NPT (R _) Thread 2.8 40 22" (56mm) 1,2,8 R3621 10mm Orifice XLH with R'"" Thread 4.2 60 56mrn 4,6,7 R3624 R3614 Conventional- Install in Upright or Pendent Position 10mm Orifice XLH with R „ Thread 4.2 60 56mm R367,1 15mrr Standard Orifice v.ith r," NPT (R') Thread 5,6 80 56mm 4,6,7 R3675 20mm Large Orifice with ,' NPT (R;,)Thread 8 0 115 58mm 1 7 R3672 Polyester coated upright UL and ULC listed corrosion resistant. - Upright Pendent Conventional Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler A royal Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) (15mm) ° NPT (R;: >l - 5,6 80 2 2„ (56mm) 1,2,3,45,7,8 R3615 (20mrr) : NPT (R/) 8 0 115 2 3" (58mm) 1,2,3,8 j R3612 :," (11 mm) ;' NPT (R'',,' 4,2 - I 60 2 2" (56mm) 128 8 - P3613 (10mm) ��" NPT (RY�) 2.8 - 40 - 2 2" (56mm), - - 1,2,6 R3611 10mm R': 4,2 60 56mm 4,7 i 83614 o ' `'1 Refer to escutcheon data table for approvals and dimensions. Model F1 FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Thread K Factor Sprinkler Approval Sprinkler Identification Orifice Size - US Metric Height Organizations -- Number (SIN) _ NPT (R'G) 5 -6 80 22" (56mm) 1.2, 3, 6, 8 - —r - - -- —_ R3685 15mrn NPT (R' /_) 5.6 80 2.2" (56mm) 4 r) LPC Approval is for Pendent position only. Vertical Sidewall US Patent No. 6,374,920 Orientation Upright Pendent Deflector to Ceiling Dimension (Min. - Max.) - — 4 ( 12" 102mm - 305r m) 6' 12'(152rmn- :30r,rn) Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations K Factor and Type of Approval Sprinkler -- -- Identification Nominal Thread Sprinkler Light T Ordinary Number (SIN) Orifice Size US Metric Length Hazard Hazard f (15mm) NPT(R %2) 5.6 80 2 63" (67n,m) 1.2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use vvith F1 or F2 recessed escutcheon. 7 Horizontal Sidewall 41 "x h M, .; 7- 0, ?i? k( ,�' ALS A ✓ u'fAE�1f nPi�- 41 Installation Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2 -81N or other applicable standards. Quick response sprin- klers and standard response sprinklers should not be inter- mixed. The Model F1 FR Recessed Quick Response Sprinklers are to be installed as shown. The Model F1 or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model F1 FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. When installing Model F1 FR Sprinklers, use the Model D Sprin- kler Wrench. When installing Model F1 FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR 1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Sprinkler Max. Ambient Bulb Classification Temperature Temp. Color I °C °F Ordinary 57 35 100 -,F(38`C) Orange Ordinary to Ceiling or I 68 155 I00`F(38'C) Red Inten7iediate 79 175 150`F(66 1C) yellow Intermediate (38.1rnm) '� C' 93 200 150'F (66'C) Green igh ('i 141 286 225T(i0 "c') Rue t'1 Not available for recessed sprinklers Escutcheon Data No Dimensional Figure for FP Maintenance The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical. Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes "' "' Standard Finishes Sprinkler -- Escutcheon Bronze Brass Chrome Plated Chrome Plated White Polyester Coatedinl 'White Painted rst Special Application Finishes Sprinkler Escutcheon Bright Brass ,Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome Othef finishes and colors are available or special o,dei Consult the factory for details - ? FM Approvals is limited to bronze and brass, chrome or black plated finishes only. isi FP Push -on ?Th read -off escutcheon. a) UL and ULC listed corrosion resisiance. SIN nun bers R3621, R3622, R3623, R3625. Note: For /1/2" orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 014. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6, Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Note: When Model F1 FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is ;o 0c it alled in accordance ✓ ith tae latest oeriincnt ;turd <ar1; of the National Fire Protection Association, Factory 1r + -_ al R(.sca- Corporation, or other similar organization- a,,)d also , rl? the provisions of governmental codes _:r ordina u, whe -ever applicable. Products manufactured and di,.trihuted by Reliable have been protec?ing life and property for over 80 ye- - r. _;nd ere - rstalled and ,e viced h7 ,ernost higi ly qunhhed e d rep,ta- ble sprinkler contractors located thmugho, it the United States. Canada and foreign countries Manufactured by Reliable The Reliable Automatic Sprinkler Co., Inc. (800)431 -1588 Sales Offices (800)848 -6051 Sales Fax (914)829 -2042 Corporate Offices wwva- reliablesprinklercorn Internet Address �i Revision lines In lc aae .jpdaied o., nem data FG. P­ 'ec ir. U.S.' llr;7 P /NY 99997' D:) P7 Face of Fitting Escutcheon on Approvals Adjustment to Ceiling or I Dimension Wall Dimension 1y' F7 1,2,4,8 Max Recess (38.1rnm) '� C' Min Recess %„ (Srnni 24rnm) _ 19.1m,,rn) -_ -- ___ - -- F2 1 L3,4,5,7'8 Max Recess f (38 Imm) Min Recess (5mm 17mn-i) Fp 1,2 Max Recessed 1 ✓, "(a3 1mm) i (11mm Push on! Threadcrf P Min Re c scd 1"(2b_4mm) �- - L- — (24rrIrn - - -- No Dimensional Figure for FP Maintenance The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical. Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes "' "' Standard Finishes Sprinkler -- Escutcheon Bronze Brass Chrome Plated Chrome Plated White Polyester Coatedinl 'White Painted rst Special Application Finishes Sprinkler Escutcheon Bright Brass ,Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome Othef finishes and colors are available or special o,dei Consult the factory for details - ? FM Approvals is limited to bronze and brass, chrome or black plated finishes only. isi FP Push -on ?Th read -off escutcheon. a) UL and ULC listed corrosion resisiance. SIN nun bers R3621, R3622, R3623, R3625. Note: For /1/2" orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 014. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6, Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Note: When Model F1 FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is ;o 0c it alled in accordance ✓ ith tae latest oeriincnt ;turd <ar1; of the National Fire Protection Association, Factory 1r + -_ al R(.sca- Corporation, or other similar organization- a,,)d also , rl? the provisions of governmental codes _:r ordina u, whe -ever applicable. Products manufactured and di,.trihuted by Reliable have been protec?ing life and property for over 80 ye- - r. _;nd ere - rstalled and ,e viced h7 ,ernost higi ly qunhhed e d rep,ta- ble sprinkler contractors located thmugho, it the United States. Canada and foreign countries Manufactured by Reliable The Reliable Automatic Sprinkler Co., Inc. (800)431 -1588 Sales Offices (800)848 -6051 Sales Fax (914)829 -2042 Corporate Offices wwva- reliablesprinklercorn Internet Address �i Revision lines In lc aae .jpdaied o., nem data FG. P­ 'ec ir. U.S.' llr;7 P /NY 99997' D:) P7