Yelm Education Center TI 21063r.. N r� N M 0 M 0 0 0 0 YELM EDUCATION CENTER, TENANT IMPROVEMENT YELM COMMUNITY SCHOOLS NO. 2 PROJECT INFORMATION SITE ADDRESS CODES 107 1ST ST. YELM, WASHINGTON 98597 PARCEL NUMBER 64400100100 64421800100 SITE AREA 27,874 S.F. LEGAL DESCRIPTION UNIFORM BUILDING CODE: 1997 UNIFORM MECHANICAL CODE: CURRENT EDITION UNIFORM PLUMBING CODE: CURRENT EDITION UNIFORM ELECTRICAL CODE: CURRENT EDITION WASHINGTON STATE ENERGY CODE ZONING C -1 PARCEL NO.: 64400100100 LOTS 1 AND 2, BLOCK 1, MCKENZIE'S FIRST ADDITION TO THE TOWN OF YELM, THURSTON CO., WASHINGTON, AS RECORDED IN VOLUME 8 OF PLATS, PAGE 26. TOGETHER WITH THAT PORTION OF THE SOUTHERLY HALF OF JEFFERSON STREET AS VACATED PER TOWN OF YELM VACATION ORDINANCE NO. 65. PARCEL NO.: 64421800100 LOTS 1 AND 2, BLOCK 18, McKENZIE'S SECOND ADDITION TO YELM, WASHINGTON, AS RECORDED NOVEMBER 28, 1916, IN VOLUME 8 OF PLATS, PAGE 104, UNDER AUDITOR'S FILE NUMBER 77865. TOGETHER WITH THAT PORTION OF THE NORTHERLY HALF OF JEFFERSON STREET AS VACATED PER TOWN OF YELM VACATION ORDINANCE NO. 65. SITUATE IN THE COUNTY OF THURSTON, STATE OF WASHINGTON. SUBJECT TO EASEMENTS, RESTRICTIONS AND RESERVATIONS OF RECORD. NORTH VICINITY MAP SITE LOCATION-` L c.. 02001 MxoQt*0.wm. Im :02001 GIRT, Im. KEY PLAN UNFINISHED AREA 9,125 S.F. UNOCCUPIED DESIGN TEAM YELM COMMUNITY SCHOOLS 404 YELM AVENUE WEST P.O. BOX 476 YELM, WA 98597 (360) 458 -1900 (360) 458 -6178 (FAX) AREA OF TENANT IMPROVEMENT HIGH SCHOOL EDUCATIONAL AREA 10,325 S.F. E -1 OCCUPANCY (E) BUILDING SCOPE OF WORK The Work consists of: The Yelm Education Center project is a tenant improvement of half of the Wolf Building in Yelm, Washington, to provide classroom space for the Yelm Extension School. Inside, the work entails demolishing misc. existing interior walls and finishes. Interior improvements include wall framing and finishes along with flooring and ceilings as noted on the drawings. The wall dividing the improved side from the unimproved will be a 1-hour occupancy separation wall. Mechanically we will get new heating units mounted on the roof. Plumbing provides new fixtures for the bathroom along with water heater and associated piping and waste. Electrical work includes new power lighting and fixtures as specified. Also included will be fire alarm system, data and telephone rough -in, clock program system, and school intercom system. No other exterior work is included here. The building was recently re- roofed and the only work here would be the curbs and roof patches at the new mechanical units. The Work will be constructed under a single prime contract. At the completion of the project the Contractor will be responsible for having the existing site amenities, i.e. grass areas, concrete walks, curbing, asphalt paving, etc., in condition equal to or better than original condition at the beginning of project. Burden of proof of "original condition" is the responsibility of the Contractor. This could be in the form of photographs or video tape. A copy of these will be turned over to the Architect prior to the beginning of construction. If this does not happen then the Architect's decision as to "original condition" will govern. STATISTICS HIGH SCHOOL OCCUPANCY CLASSIFICATIONS INSTRUCTIONAL AREA WITH ADMINISTRATION E -1 BUILDING OCCUPANCY LOADS OCCUPANCY PER TABLE 10-A E -1 478 CONSTRUCTION TYPES TYPE VN (NOT SPRINKLED) ACTUAL / ALLOWABLE BUILDING AREAS E -1 OCCUPANCY ACTUAL 10,325 10,325 ALLOWABLE 9,100 (+ 7,053 SEPARATION 3 SIDES) 16,153 16,153>10,325 TYPE VN OK LEGEND 1 _ A3.0 SECTION SYMBOL ENTRY (E) ROOM NAME 2 A9.2 DETAIL SYMBOL D4 INTERIOR ELEVATION SYMBOL 1/EIA7.3 ELEVATION SYMBOL 0 - - - GRID LINE SYMBOL ENTRY REVISED ROOM NAME & ROOM NUMBER tot EXISTING NOTE ENTRY (E) ROOM NAME t 2 BUBBLE NOTE D4 AREA OF WORK AS NOTED N2 ELEVATION SYMBOL ARCHITECT ERICKSON McGOVERN, PLLC 120 SOUTH 131 ST STREET TACOMA, WASHINGTON 98444 (253) 531-0206 (253) 531 -9197 (FAX) CONTACT: STEVE STORAASLI 6' U.N.O. DOOR SYMBOL DOOR NUMBER EXISTING DOOR SYMBOL Et EXISTING NOTE �t DEMO NOTE Nt NEW NOTE Q2 RELITE SYMBOL, SEE A2.0 FOR LOCATION N2 & AID FOR TYPE WALL TYPE SYMBOL SEE A2.0 FOR LOCATION A.C.P. & A2.1 FOR ASSEMBLES ADJ. WALL TO BE DEMOLISHED A.F.F. WOOD STUD WALL FULL HT. TO UNDER SIDE 3 �,� MM051 _ ,: OF ROOF STRUCTURE U.N.O. 1 -HR OCCUPANCY SEPERATION WALL. FULL HT, FROM SLAB TO UNDERSIDE OF ROOF SHEATHING PARTIAL HT. WALL. SEE A2.0 FOR HEIGHTS EXISTING WALL MECH. /ELECTRICAL ENGINEER HULTZ / BHU, INC. 2407 NORTH 31ST STREET, SUITE 200 TACOMA, WA 98407 (253) 383-0257 (253) 383.3283 (FAX) CONTACT: TED VEACH (MECHANICAL) TOM URQUHART (ELECTRICAL) ABBREVIATIONS Q AT MECH. CENTERLINE O DIAMETER OR ROUND # POUND OR NUMBER A.B. ANCHOR BOLTS A.C.P. ACOUSTICAL CEILING PANEL ADJ. ADJUSTABLE A.F.F. ABOVE FINISH FLOOR BD. BOARD BIT. BITUMINOUS BLDG. BUILDING BLKG, BLOCKING BM. BEAM BOT. BOTTOM C.J. CONTROL JOINT C.L. CHAIN LINK CLNG. CEILING COL. COLUMN CONC. CONCRETE CONST. CONSTRUCTION CONT, CONTINUOUS CPT. CARPET C.T. CERAMIC TILE DBL. DOUBLE DIA. DIAMETER DO. DITTO DP. DEEP DS. DOWNSPOUT ETC, ETCETERA EA. EACH E.J. EXPANSION JOINT ELECT. ELECTRICAL ELEV. ELEVATION EQ. EQUAL EQUIP. EQUIPMENT EXH. EXHAUST (E) EXISTING EXT. EXTERIOR F.A. FIRE ALARM FNDN. FOUNDATION FIN. FINISH FIN.FL. FINISH FLOOR FT. FOOT OR FEET FTG. FOOTING FX. FIRE EXTINGUISHER GA. GAUGE GALV. GALVANIZED G.W.B. GYPSUM WALLBOARD HACP. HUNG ACOUSTICAL CEILING PANELS H.M. HOLLOW METAL HT. HEIGHT I.D. INSIDE DIAMETER IN. INCHES INSUL. INSULATION INT. INTERIOR JT. JOINT JST. JOIST LAM. LAMINATED LAV. LAVATORY Vrl l/ rr111n A TVLI r r\ITrb L.F. LINEAL FEET MAX. MAXIMUM M.B. MARKER BOARD MECH. MECHANICAL M.D.O. MEDIUM DENSITY OVERLAY MIN. MINIMUM OR MINUTE MTL. METAL N.I.C. NOT IN CONTRACT NO. NUMBER N.T.S. NOT TO SCALE O.C. ON CENTER OCC. OCCUPANCY O.F.C.I. OWNER FURNISH CONTRACTOR INSTALL O.F.O.I. OWNER FURNISH OWNER INSTALL OPP. HND. OPPOSITE HAND PAV. PAVEMENT P.L. PROPERTY LINE P.LAM. PLASTIC LAMINATE PLYWD. PLYWOOD PR. PAIR PT. PAINT P.W. PLYWOOD R.B. RUBBER BASE RECPT. RECEPTACLE READ. REQUIRED REV. REVISIONS S.C. SOLID CORE SCHED. SCHEDULE S.F. SQUARE FOOT SECT. SECTION SIM. SIMILAR SPEC. SPECIFICATION SQ. SQUARE S.S. STAINLESS STEEL STD. STANDARD STL. STEEL STOR. STORAGE STRUCT. STRUCTURAL OR STRUCTURE S.V. SHEET VINYL TB. TACKBOARD T &G TONGUE & GROOVE THK. THICK T.S. TUBE STEEL TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE VERT. VERTICAL VWC. VINYL WALL COVERING W. WIDE W/ WITH WD. WOOD WDW. WINDOW W.G. WIRE GROMMETS W.O.M. WALL OFF MAT W/O WITHOUT WST. WAINSCOT W.W.F. WELDED WIRE FABRIC SITE PLAN SCALE: 1" = 100' SCHEDULE OF DRAWINGS A0.1 TITLE SHEET - PROJECT INFORMATION A2.0 FLOOR PLAN A2.1 WALL TYPES/ ENLARGED PLANS & ELEVATIONS A5.0 RELITE /SPECIALTY FRAME TYPES, DOOR TYPES, DETAILS E3.1 AND DOOR SCHEDULE A6.0 REFLECTED CEILING PLAN A8.0 MISC. DETAILS MO.1 MECHANICAL LEGEND, NOTES & SCHEDULES M1.1 FLOOR PLAN - HVAC DEMOLITION M2.1 FOUNDATION PLAN -PLUMBING M3.1 FLOOR PLAN - PLUMBING M3.2 PLUMBING DETAILS M4.1 FLOOR PLAN - HVAC M4.2 HVAC DETAILS E0.1 ELECTRICAL LEGEND & FIXTURE SCHEDULE E1.1 ELECTRICAL DEMO LIGHTING PLAN E1.2 ELECTRICAL DEMO POWER & SIGNAL E2.1 ELECTRICAL LIGHTING PLAN E3.1 FLOOR PLAN - POWER & SIGNAL E5.1 ELECTRICAL ONE LINE DIAGRAM E7.1 ELECTRICAL DETAILS DRAWING NOTES DEMOLITION - REMOVE EXISTING Dl REMOVE EXISTING DOOR & FRAME FD-2--1 REMOVE EXISTING WALL ASSEMBLY TO EXTENT REQUIRED FOR NEW CONSTRUCTION. FD-37 REMOVE EXISTING SHEET VINYL FLOORING MASTIC & BASE. PREP. FOR NEW. NEW TO BE PROVIDED N 1 7 VISUAL DISPLAY BOARD - WIDTH NOTED BY 4'-0" HEIGHT U.N.O. FN_ 2 NEW FINISHES TO FLUSH & BLEND W/ (E) N3 2x FRAMING & FINISH TO MATCH ADJ. (E) N4 4' CONCRETE SLAB, VAPOR BARRIER & SLAB BASE COURSE PATCH /INFILL TO LOCATION & EXTENT REQUIRED FOR DEMOLITION OF EXISTING & INSTALL ON NEW MECHANICAL & ELECTRICAL SYSTEMS. SEE MECH & ELEC. DRAWINGS. MAKE LEVEL & PROVIDE SMOOTH TRANSITION. N5 PATCH (E) WALL SURFACES WHERE EXISTING WALL WAS DEMOLISHED. FINISHES TO MATCH ADJACENT. APPROVED AS NQTED , GENERAL NOTES 1) ANYTHING NOT SPECIFICALLY CALLED OUT AS EXISTING (E) IS NEW TO BE PROVIDED. EXISTING CONDITIONS THE DRAWINGS CONTAIN REFERENCE TO EXISTING CONDITIONS, MATERIALS, FURNISHINGS, AND EQUIPMENT. THE INFORMATION IS DEVELOPED FROM EXISTING DRAWINGS AND SITE AND BUILDING OBSERVATIONS, AND IS PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. IT IS TO BE ASSUMED THE BUILDING IS NOT LEVEL, SQUARE, OR PLUMB. SUBMITTING A BID SHALL INDICATE THE CONTRACTORS ACCEPTANCE OF THE EXISTING CONDITIONS, AND WILLINGNESS TO PROVIDE THE LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO COMPLETE THE WORK INTENDED BY THE CONTRACT DOCUMENTS. Z O_ t•--- 0 Z U O E-- L1J L_U J � N W 4t Z W 0 U0 ..ZU F_ Z ~ �_ 0 (� z `�' Z:) Q N Q zw0 w UUC Q L 0 w -� 3828 REGISTERED AR ITECT .,_ 40 J 11 V I V. STATE F WASHINGTON PROJECT 21063 DRAWN: GP DATE 3/27/03 PERMIT SET SHEET A0.1 OF: c o o E 0 t7f C. U h CO Cl) O UU N N U d O � U trC, O C> E 0 t � V �N -N z J ° C W o r +� C M a E I� CJ t CV o U J L t Z O_ t•--- 0 Z U O E-- L1J L_U J � N W 4t Z W 0 U0 ..ZU F_ Z ~ �_ 0 (� z `�' Z:) Q N Q zw0 w UUC Q L 0 w -� 3828 REGISTERED AR ITECT .,_ 40 J 11 V I V. STATE F WASHINGTON PROJECT 21063 DRAWN: GP DATE 3/27/03 PERMIT SET SHEET A0.1 OF: N M g N S 0 LEGEND 1 _ A3.0 2 A9.2 1/E/ ` V w o- ENTRY tot ENTRY 12 SECTION SYMBOL DETAIL SYMBOL INTERIOR ELEVATION SYMBOL – — GRID LINE SYMBOL REVISED ROOM NAME & ROOM NUMBER 1 7 6 5 4 3 2 1 \ 6" U.N.O. DOOR SYMBOL CAL, :� DOOR NUMBER (E) ROOM NAME WOOD STUD WALL FULL HT. TO UNDER SIDE OF ROOF STRUCTURE U.N.O. BUBBLE NOTE I -HR OCCUPANCY SEPERATION WALL. FULL HT. FROM SLAB TO UNDERSIDE OF ROOF SHEATHING AREA OF WORK AS NOTED PARTIAL HT. WALL. SEE A2.0 FOR HEIGHTS EXISTING WALL ELEVATION SYMBOL DRAWING NEW NOTES: NEW TO BE PROVIDED N1 VISUAL DISPLAY BOARD- WIDTH NOTED BY 4'-0" HEIGHT U.N.O. N2 NEW FINISHES TO FLUSH & BLEND W/ (E) N3 2x FRAMING & FINISH TO MATCH ADJ. (E) N4 4" CONCRETE SLAB, VAPOR BARRIER & SLAB BASE COURSE PATCH /INFILL TO LOCATION & EXTENT REQUIRED FOR DEMOLITION OF EXISTING & INSTALL ON NEW MECHANICAL & ELECTRICAL SYSTEMS. SEE MECH & ELEC. DRAWINGS. MAKE LEVEL & PROVIDE SMOOTH TRANSITION. N5 PATCH (E) WALL SURFACES WHERE EXISTING WALL WAS DEMOLISHED, FINISHES TO MATCH ADJACENT. FLOOR PLAN some: v8• - t -or Os q o v c EXISTING DOOR SYMBOL t t EXISTING NOTE �t DEMO NOTE rtt 1 NEW NOTE A RELTTE SYMBOL, SEE A2.0 FOR LOCATION N2 & A5.0 FOR TYPE WALL TYPE SYMBOL, SEE A2.0 FOR LOCATION � & A2.1 FOR ASSEMBLIES ______ WALL TO BE DEMOLISHED (E) ROOM NAME WOOD STUD WALL FULL HT. TO UNDER SIDE OF ROOF STRUCTURE U.N.O. BUBBLE NOTE I -HR OCCUPANCY SEPERATION WALL. FULL HT. FROM SLAB TO UNDERSIDE OF ROOF SHEATHING AREA OF WORK AS NOTED PARTIAL HT. WALL. SEE A2.0 FOR HEIGHTS EXISTING WALL ELEVATION SYMBOL DRAWING NEW NOTES: NEW TO BE PROVIDED N1 VISUAL DISPLAY BOARD- WIDTH NOTED BY 4'-0" HEIGHT U.N.O. N2 NEW FINISHES TO FLUSH & BLEND W/ (E) N3 2x FRAMING & FINISH TO MATCH ADJ. (E) N4 4" CONCRETE SLAB, VAPOR BARRIER & SLAB BASE COURSE PATCH /INFILL TO LOCATION & EXTENT REQUIRED FOR DEMOLITION OF EXISTING & INSTALL ON NEW MECHANICAL & ELECTRICAL SYSTEMS. SEE MECH & ELEC. DRAWINGS. MAKE LEVEL & PROVIDE SMOOTH TRANSITION. N5 PATCH (E) WALL SURFACES WHERE EXISTING WALL WAS DEMOLISHED, FINISHES TO MATCH ADJACENT. FLOOR PLAN some: v8• - t -or Os q o v c z Q J IL Q� 0 0 L.L ry N W 4t H � w0 U0 .. z U Fo>- z F- 0 < z F— U Z:) Q�� Z w0 o � oJ� W J :>: >- L>U- 3828 1 REGI STEVE LSTORAASLI' TATE Or WASHINGTON DRAWING DEMOLITION NOTES: = REMOVE EXISTING DOOR & FRAME PROJECT 21063 FD-2-1 REMOVE EXISTING WALL ASSEMBLY TO EXTENT REQUIRED FOR NEW CONSTRUCTION. DRAWN: GP D3 REMOVE EXISTING SHEET VINYL FLOORING MASTIC & BASE. PREP. FOR NEW. DATE 3/27/03 GENERAL NOTES: PERMIT SET 1. ANYTHING NOT SPECIFICALLY CALLED OUT AS EXISTING (E) IS NEW TO BE PROVIDED. SHEET 2. SEE MECHANICAL & ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION REQUIREMENTS. A24,0 3. CONTRACTOR IS REQUIRED TO PROVIDE FRAMING & PATCHING TO MATCH EXISTING ADJACENT SURFACE FINISHES AT ALL CONDITIONS OF MECHANICAL, ELECTRICAL, & ARCHITECTURAL DEMOLITION AND NEW INSTALLATIONS. OF: 4. FOR ROOFING & FLASHING DETAILS FOR NEW ROOF TOP MECHANICAL UNIT SEE DETAILS 6/A8.0, 7/A8.0, & 8/A8.0 y � L O N N U \ � N x C O 1 � � U \ O O C� O 0 \ V \ u N N \ ��J // lLC� �O C 1 � 0� Y � O V di N H � c Q O 4-a •r v N o L L z Q J IL Q� 0 0 L.L ry N W 4t H � w0 U0 .. z U Fo>- z F- 0 < z F— U Z:) Q�� Z w0 o � oJ� W J :>: >- L>U- 3828 1 REGI STEVE LSTORAASLI' TATE Or WASHINGTON DRAWING DEMOLITION NOTES: = REMOVE EXISTING DOOR & FRAME PROJECT 21063 FD-2-1 REMOVE EXISTING WALL ASSEMBLY TO EXTENT REQUIRED FOR NEW CONSTRUCTION. DRAWN: GP D3 REMOVE EXISTING SHEET VINYL FLOORING MASTIC & BASE. PREP. FOR NEW. DATE 3/27/03 GENERAL NOTES: PERMIT SET 1. ANYTHING NOT SPECIFICALLY CALLED OUT AS EXISTING (E) IS NEW TO BE PROVIDED. SHEET 2. SEE MECHANICAL & ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION REQUIREMENTS. A24,0 3. CONTRACTOR IS REQUIRED TO PROVIDE FRAMING & PATCHING TO MATCH EXISTING ADJACENT SURFACE FINISHES AT ALL CONDITIONS OF MECHANICAL, ELECTRICAL, & ARCHITECTURAL DEMOLITION AND NEW INSTALLATIONS. OF: 4. FOR ROOFING & FLASHING DETAILS FOR NEW ROOF TOP MECHANICAL UNIT SEE DETAILS 6/A8.0, 7/A8.0, & 8/A8.0 0 c � E o ° ^ O: p. E WALL TYPES EXISTING WALL TYPES H A o N N U d uu 0 O 0 N1 E1 r O 5/8" GWB TYPE W 5/8" GWB TYPE'X' c 0 2x6 @ I C O.C. 2x6 @ i G' O.C. R -19 BATT INSULATION - R -19 BATT1NSULATION 0 El El 5/8" GWB TYPE W 5/8" GWB TYPE'X' STORAGE �!N N 011 _ 1 -HR CONSTRUCTION 1-HR CONSTRUCTION GA FILE NO WP 3605 GA FILE NO WP 3605 2'-6" _ � r o N2 E2 av • ; �,..,: „�, Ste„ .,,,.*fin :°`, ` ;,*`.�!tu€a.o,,.i9X£"r -.,, ..: '> c- .r.:..,..� 'h'... r.;» z 2 x 6 WD. STUDS @ 16" O.C. 2x6 @ 16" O.C. � N 1 5/8 "GWB R 19 BAIT INSULATION Q, 4A� /A22 L1- SOUND ATTENUATION 5/8" GWB TYPE W ° REF. v -� NIC +� DELETE SOUND ATTENUATION °- as AT PARTIAL HT, WALLS, SEE A2.0 h +.0 EXISTING 3- COMPARTMENT SINK o CEILING TYPES O tj A� L C1 1/7' EXT PLYWOOD GLUED & NAILED 2x10 @16 "O.C. KITCHEN 1 9 i (2) LAYERS 5/8" GWB TYPE'X' N2 � HANDWASH 2 „ , SINK i N 1 -HR HORIZONTAL OCCUPANCY 51- 1 012A 2--_T u _ _ _ _ J SEPARATION VCT ASV I-H © GAFILE CONSTRUCTION RANGE NO RC 2601 j HOOD N1 N1 i © C2 :k O 1 © (D g� B TFfR00M A/ `� � 2 x FRAMING @ 16" O.C. PER 46/A2.2 NI 2 6„ FRAMING SCHEDULE ON A6.0 / s 0128 �� �b 5/8" GWB TYPE'X' - �jt SW VCT � \�� S O2 MICRO �y. __ _ ____ .---- - - - - -- - NIC kk 7 0120 MATCH ADJACENT 13'-0" N2 SURFACES Z O F- Q ENLARGED BATHROOM PLAN ENLARGED KITCHEN PLAN WALL TYPES &CEILING TYPES > � 2 � J Scale: 1/4" = 1' -0" Scale: 1/4" = 1' -0" Scale: 1" = 1' -O" W 06 N Z L RANGE HOODS SEE A5.0 A5.0 ABOVE CLG. COILING A5.0 A5.0 ABOVE CLG. COILING Q t/) MECH. FOR THROUGH DOOR HOUSING. DOOR HOUSING. -� Z J WALL VENT CONNECTIONS n-- - - - - -- ---- - - - - -- - -- i R - - -- - - ~- - - - - - -- n ANGLEINI4LL LL L O - o U O L - _ =- —_ _ — FRP F p� l�J .. Z tU FRP - - -- -- - -- - - _= Q FRP \ FRP - -- - _ _ -- - -- \ Z Z l,_ REF. i L1J O Z NIC i I- U 00 0 00 00 a 00 (n Q / i i NIC NIC / a- Z O F- Q LU L ----- J 6" S.V. EXISTING 3- COMPARTMENT J L1J OA O O A5.0 O A5.0 O COVE BASE SINK Q O J J w1j KITCHEN ELEVATIONS 4 Scale: 1/4" = 1' -O" 3828 1 REGI COLUMN 3' p" 0 FLUSH LEVER TO CEILING STATE OPEN SIDE OF TOILET 7-6" " 4'-0" 3 %0' 1 f�, 0 0 I��" r' zo 7g 4 - - - _ _ _ _ _ PROJECT 21063 :w - r _ En _ — DRAWN: GP DATE 3/27/03 F.F. OO O O O O n7 O 10 11 ? 12 13 • / � PERMIT SET MIRROR SOAP PAPER SEAT SANITARY SANITARY TOILET GRAB GRAB URINAL TOILET SHOWER BARRIER 18X30 DISP. TOWEL COVER NAPKIN NAPKIN PAPER BARS BARS PARTITION PARTITION CURTAIN FREE LAV. 6" S.V. SHEET g (U.N.O.) (O.F.CJ.) DISP. DISP. DISP. RECEPTACLE DISPENSER NOT USED NOT USED &ROD (INSULATE a (O.F.C.I.) NOT USED NOT USED (O.F.C.I.) NOT USED PIPES) COVEBASE ko 0 0 0 0 A2.1 ' BATHROOM ACCESSORY HEIGHTS BATHROOM ELEVATIONS s 6 5 OF: Scale: 1/4" = V-T Scale: 1/4" = 1' -0" Co N O 0 DOOR 001 NON -RATED 17-0" 3 A5,0 I� 2 SAFETY GLAZING TYP. v 8'-0" v 60 MIN. 60 MIN. WINDOW TREATMENT SEE SPEC. INSTALL ON OCCUPIED SIDE TYP. WINDOW STOP ON OCCUPANCY SIDE TYP. HM FRAME SOLID GROUT SEALANT TYP. SEE PLANS FOR WALL TYPE HEAD, JAMB &SILL @ RECITE Scale: 3' = 1'4" CEILING HT SEE A6 e� F- b CV COILING DOOR TYPES Scale: 1/4" = V-T WALL WIDTH PLUS 1" SEE PLANS FOR WALL TYPES SEALANT TYP. H.M. DOOR FRAME FILL W /STRUCTO -CITE DOOR. SEE SCHEDULE DOOR JAMB -INT. (HEAD SIM) Scale: 3" = 1'-T TYP. INTERIOR HM FRAME NOTE: SEE DOOR SCHEDULE FOR SIZE & FRAME TYPE. DOOR FRAME TYPES Scale: 1/4" = 1' -T CEILING DOOR HOOD BRACKET PLATE BY DOOR MANUFACTURER PROVIDE SOLID 2x BLOCKING FOR DOOR ATTACHMENT. 10' -7' A.F.F. ,` IV 9'-0'' A.F.F. GWB CEILING AT KITCHEN ACP @ SIM CONDITION COILING DOOR HEAD Scale 'l 1/2" = 1' -T 1x2 PLAM TRIM SILL BELOW (NO CONDITIONS) o a NOTE: SEE DOOR SCHEDULE FOR SIZE & FRAME TYPE. DOOR TYPES Scale: 1/4" = 1' -O" SEE PLAN FOR WALL TYPE CONT. 2x4 BLOCKING FOR TRACK ATTACHMENT 5/8" GWB TYPE 'X' 2x BLOCKING DOOR TRACK COILING DOOR PLAM WRAP @ HEAD & JAMB COILING DOOR JAMB Scale *1 1/2" = 1' -0" 7-7 7-611 A A NOTE: PROVIDE SAFETY GLASS @ RELITE CONDITION RECITE FRAMES Scale: 1/4" = 1'-0" COILING DOOR GWB WRAP @ TRACK PLAM OVER 1 1/4" PLYWOOD COUNTERTOP 5/8" GWB TYPE'X' OVER DBL 2x4 BLOCKING SEE PLANS FOR WALL TYPE COILING DOOR SILL Scale 1 1/2" = 1'-O" N uj H �1 �N ICI w CL Lu Q Iv u- An Lij IZ W Lu O J >ZQ > W cY 0 0o OZ OQ N W 41Z ~ J ZO W UO .. Z U 0 O >-- Z ~ F- 0 < z 1= U ZD Q IV o Z w0 w U 0 ]�j O -' W Z> >- >- REGIS "STEVEfO' . (STORAASE I STATE WASHINGTON PROJECT 21063 DRAWN: GP DATE 3/27/03 PERMIT SET SHEET A5.0 c Co '0 E o P U H Lo fl � A �uu� G N N U m o C O U O C� E cn N •N z b W ° L VU E � u V d p � o U o o E O L 4 N uj H �1 �N ICI w CL Lu Q Iv u- An Lij IZ W Lu O J >ZQ > W cY 0 0o OZ OQ N W 41Z ~ J ZO W UO .. Z U 0 O >-- Z ~ F- 0 < z 1= U ZD Q IV o Z w0 w U 0 ]�j O -' W Z> >- >- REGIS "STEVEfO' . (STORAASE I STATE WASHINGTON PROJECT 21063 DRAWN: GP DATE 3/27/03 PERMIT SET SHEET A5.0 ►2 G M 0 rn 8 N V4' O 9 8 T I I 6 5 4 3 2 1 I 1 I I I I I --� 1 - I I I 9 8 7 6 5 4 3 2 1 CEILING LEGEND 7 x N ACP TYPE 1 CEILING GRID LIGHTING EXISTING 7 x 4' ACP CEILING GRID D EXISTING LIGHTING GWB CEILING CEILING TYPES 7 x 7 ACP TYPE 2 CEILING GRID OGWB SEE A2.1 FOR ASSEMBLY 17' x 17' ACP TYPE 3 CEILING GRID CEILING FRAMING SCHEDULE LEDGER SIMPSON SPAN FRAMING (2) BLOCKING HANGER STUDS @ 16" O.C. STUDS i� 16" O.C. 0' TO 10' 2x6 @ 16" O.C. NA (2) 16d EA. STUD (3) 16d EA. STUD LUP 24 10' TO 15' I 2x8 @ 15 O.C. I MIDSPAN (3) 16d EA. STUD (4) l6d EA. STUD LUP 24 15' TO 20' 2x10 16" O.C. 1 /3 POINTS (4)16d EA. STUD (6) 16d EA. STUD LUP 26 GENERAL NOTES: 1) ANYTHING NOT SPECIFICALLY CALLED OUT AS EXISTING (E) IS NEW TO BE PROVIDED. CEILING FRAMING NOTES: 1) CEILING FRAMING LOADING 15 P.S.F. L.L. + 20 P.S.F. LIVE LOAD. 2) BLOCKING SHALL BE FULL DEPTH OF JOISTS AND SHALL BE END NAILS W /(3) 16d TYPICAL EA. JOIST SPACE. BLOCKING MAY BE OMITTED ON JOISTS W/ 1 /7' MIN. SHEATHING NAILED TO TOP OF JOIST. REFLECTED CEILING PLAN Sca . V80 0 .r -Ow �J \J L� J a i u W 8 Q cQ: SZ �^ O fl N 6 Lu Lo L Lo Lo N to N N V � o r U Lb O � O �O E v �n N .r. N r ep C • d7 L V i d i V L t z Q 12 z w U wil uj w J LL- ui w w N W U I— cn z -' w0 U0 s ..zu 0 0 �- Z 0Qz P=UZD Q�� 1V Q Z LLJ 0 w U 0 � � 0w Uj 12 >- >- 3828 1 REGISTERED 8?EVEN � AASLI STATE OF ASHINGTON PROJECT 21063 DRAWN: GP DATE 3/27/03 PERMIT SET SHEET A6.0 OF: �NSIIION IN PARTIAL HT. IN !Y 021 CARRY WD CAP & 'ERTICALLY UP EACH SIDE. ILLNOSE TYP. ALL CORNERS kPLE TRIM - STAIN. MITER ALL ERS R. MAPLE TRIM - STAIN. DE EASED EDGES AT ED CORNERS WALL CAP Scale: 3" = 1'-0" C� 0 0 _o N O FIBERGLASS COLUMN COVER 17' DIA. COLUMN @INTERIOR Scale: 3" = V-a' ACP @ 12'4" A.F.F. ot ACP @ 194" A.F.F. MECH'L UNI FLASHING C FLASHING II' BASE SHEET CANT STRIP (E) RIGID IN; VARIES (E) SURFACE 5/8" GWB TYP'X' 5/8" MDO PT. — 7-0" rnk IT 116. �.8 W/ 5/8" GWB TYPE'X' WRAP SOFFIT I� FOR ATTACHMENT TO STRUCTURE SEE 1 /A8.0 CONT. BLOCKING @ CLG. TERMINATION TYP. 2x6 @ 24" O.C. VERT. FRAMING CONT. 2x6 BLOCKING \ 20 KICKER @ J� 24" O.C. ` 2x4 @ 24" O.C. TYP, DETAIL r- Scale 1 1/2" = V-9' CURB FLASHING Scale: 3" = 1' -0" HVACI 3/4" PLl (E) PLYV 4X6SLELrLR T/- IV irtwaLJ. FrVrwLJnun Viv -- LOWER SIDE TO PROVIDE LEVEL PLATFORM FOR HVAC UNIT. SECTION THRU MECH UNIT CONT. 2x6 TYP. EXISTING TJI ROOF STRUCTURE 2x6 CROSS BLOCKING @ 24" O.C. 2X6 @ 24" O.C. VERT. FRAMING TYP. \ PROVIDE CONT. 2x BLOCKING @ CLG. TERMINATION TYP. SOFFIT DETAIL Scale *1 1/2" = 1' -O" Scale: 3/4" = 1' -T SOFFIT DETAIL 1 N Scale1 1/2" = 1' -T E ,In N a w z w CONT. 2x6 TYP. Lu EXISTING TJI ROOF STRUCTURE 2x6 CROSS BLOCKING @ 24" O.C. 2x6 @ 24" O.C. VERT. u FRAMING TYP. 2x CEILING FRAMING SEE A6.0 • z PROVIDE CONT. 2x BLOCKING @ CLG. 0 TERMINATION TYP. V v a DETAIL 1 N Scale1 1/2" = 1' -T E ,In N a w ULwt -Urr MW COORDINATE DUCT OPENING ---- W/MECH'L. DO NOT CUT TRUSS PLAN VIEW MECH UNIT ON ROOF Scale: 3/4" = 1' -0" _J Q W 0 U ►: = a o^ E CD �, o 0 E N C6 C6 o o N N V � � c 0 Lb y i � U O C�i o 'o E v cn N .v a� L t w CN U-1 Z -' w0 UO s .. Z U 0Qz I-- U= Z IV 0 z w0 W u 0�> O w ­2 >- >- 382 REGISTERED AR I I CT I STATE 40 WASHINGTON PROJECT 21063 DRAWN: GP DATE 3/27/03 PERMIT SET SHEET A8.0 ra (E) TRUSSES @ 37' O.C. uj 0 u- 0 0 7 A8.0 x6 (FLAT) SHORING FOR HVAC UNI TO SPAJ MIN. 8' 4- TRUSSES) FOR 46 UNITS AND 12' ( TRUSS E x NITS. WIDTH BETWEEN 4x6'S BASED 1014 HVAC UNIT URBS. min mp wvAr INIT 46 (FLAT) TO ULwt -Urr MW COORDINATE DUCT OPENING ---- W/MECH'L. DO NOT CUT TRUSS PLAN VIEW MECH UNIT ON ROOF Scale: 3/4" = 1' -0" _J Q W 0 U ►: = a o^ E CD �, o 0 E N C6 C6 o o N N V � � c 0 Lb y i � U O C�i o 'o E v cn N .v a� L t w CN U-1 Z -' w0 UO s .. Z U 0Qz I-- U= Z IV 0 z w0 W u 0�> O w ­2 >- >- 382 REGISTERED AR I I CT I STATE 40 WASHINGTON PROJECT 21063 DRAWN: GP DATE 3/27/03 PERMIT SET SHEET A8.0 ra GAS HEAT/ ELECTRIC COOLING UNIT SCHEDULE - PACKAGED TYPE SYMBOL SPECIFIED MANUFACTURER AND SERIES NUMBER ** AREA SERVED COOLING CAP. * HEATING CAP. SUPPLY FAN COMPRESSOR CONDENSOR FAN ELECTRICAL FILTERS MIN.OA MAX. WEIGHT REMARKS TOTAL MBH SENS. MBH SEER OUTPUT MBH AFUE CFM ESP HP QTY RLA EA QTY HP MCA V /PH TYPE MIN. SF HVAC -5 TRANE YSC 048 CLASSROOM 015 49.2 47.0 10.0 64.0 81 1480 �� 0.5 .60 1 14.6 1 .33 23.9 208/3 309 EFF 3.5 550 750 W/ 0 -100% OA ECONOMIZER, ROOF CURB 233 W _ DIRECT WALL SWITCH 50 115/1 10x10 1 200 ADJUSTABLE CORE RVR ROOF VENT GREENHECK WRH LOW PROFILE LOUVERED CLG CEILING RELIEF PENTHOUSE NOTES: 1. PROVIDE ALL DIRECT DRIVE FANS W/ SPEED CONTROL. 2. PROVIDE ALL ROOFTOP FANS W/ ROOF CURBS. 3. PROVIDE ALL FANS W/ BDD. WALL SUPPLY KRUEGER S580H HORIZ. FACE BARS 3/4" COP COMP COEFFICIENT OF PERFORMANCE COMPRESSOR GRILLE - -- O.C., 35' DEFLECTION AIR INLET & OUTLET SCHEDULE NOTES: 1. CEILING DIFFUSERS (CD) SHALL HAVE NO. & DIRECTION OF THROWS AS INDICATED ON PLANS. (E.G. CD -3 = 3 WAY THROW) 2. ALL AIR TERMINALS SHALL HAVE FACTORY FINISH, COLOR AS SELECTED BY ARCHITECT. 3. SEE LEGEND FOR TERMINOLOGY USED IN AIR TERMINAL CALL -OUTS ON DRAWINGS. 4. SEE ARCH. FINISH SCHEDULE FOR CEILING TYPES, PROVIDE AIR TERMINALS TO MATCH CEILING CONSTRUCTION INSTALLED IN. 5. SEE SECTION 15870 FOR SPECIFICATIONS. COLD WATER DEGREE FAHRENHEIT DKF- COMBINATION SHUT -OFF & BALANCING VALVE DIA, ff DN DIAMETER DOWN CHECK VALVE DWG DB DRAWING DRY BULB -- -1�'1- BUTTERFLY VALVE DL EA DOOR LOUVER EACH <y -il�- * COOLING CAPACITY IS ARI RATING: AT 80' F DB; 67' F WB ** MODEL NO.S ARE PRELIMINARY, CONTRACTOR SHALL PROVIDE LATEST MFR'S INDOOR COIL EAT AND 95' F OUTDOOR COIL EAT. MODELS, MEETING CAPACITIES & EFFICIENCIES SCHEDULED. FAN SCHEDULE SYMBOL SPECIFIED MANUFACTURER AND SERIES NUMBER TYPE AREA SERVED CFM ESP RPM WHEEL DIA ELECTRICAL DRIVE CONTROL MAX WEIGH IN LBS REMARKS HP V/ pH EF -4 COOK 100 TLC 15 ROOFTOP LOW PROFILE KITCHEN 012 500 0.375' 1550 - 1 /8 115/1 DIRECT TIME CLOCK 110 1 EF -5 COOK GC 140 CEILING EXHAUST TOILET 100 0.25" 1500 - 70 W 115/1 DIRECT TIME CLOCK 30 INDEECO QUA EF -6 COOK GC 620 CEILING EXHAUST LUNCH ROOM 007 340 0.25" 960 - 233 W 115/1 DIRECT WALL SWITCH 50 115/1 10x10 1 200 ADJUSTABLE CORE RVR ROOF VENT GREENHECK WRH LOW PROFILE LOUVERED CLG CEILING RELIEF PENTHOUSE NOTES: 1. PROVIDE ALL DIRECT DRIVE FANS W/ SPEED CONTROL. 2. PROVIDE ALL ROOFTOP FANS W/ ROOF CURBS. 3. PROVIDE ALL FANS W/ BDD. ELECTRIC DUCT HEATER SCHEDULE SYMBOL SPECIFIED MANUFACTURER AND MODEL NUMBER TYPE AREA /UNIT SERVED ELECTRICAL NOMINAL SIZE STAGES CFM REMARKS KW VOLTS /PH EDH -1 INDEECO QUA OPEN COIL LIBRARY 021 2.5 115/1 12x8 1 360 - 700 EDH -2 INDEECO QUA OPEN COIL OFFICE 001 1.0 115/1 10x10 1 160 16" 0 EDH -3 INDEECO QUA OPEN COIL LUNCH ROOM 012 3.0 115/1 1200 1 480 (2) 1 2" EDH -4 INDEECO QUA OPEN COIL KITCHEN 012 3.5 115/1 12x10 1 560 BLDG EDH -2 INDEECO QUA OPEN COIL RECEPTION 002 1.5 115/1 10x10 1 200 ADJUSTABLE CORE MECHANICAL GENERAL NOTES 1. VERIFY LOCATION OF PLUMBING FIXTURES WITH ARCH. DRAWINGS BEFORE BEGINNING WORK. ARCH. DWGS. GOVERN. 2. PLUMBING FIXTURE HEIGHTS SHALL BE AS SHOWN ON ARCH. DRAWINGS. 3. FOR TRANSFER DUCT DETAIL SEE DETAIL 1 SHEET M4.2. ALL TRANSFER DUCTS SHALL BE INTERNALLY LINED. 4. ALL FLOOR DRAINS, FUNNEL DRAINS, AND FLOOR RECEPTORS SHALL HAVE TRAP PRIMERS, SEE DETAIL 1 SHEET M3.2. 5. ALL DUCT WALL PENETRATIONS THRU WALLS AND ROOM WALLS /FLOORS SHALL BE PROVIDED WITH CLOSURE COLLARS AND BE TIGHTLY SEALED TO PREVENT THE TRANSMISSION OF NOISE. 6. CONTRACTOR SHALL CAREFULLY COORDINATE WORK W/ ALL OTHER TRADES, ESPECIALLY IN CEILING SPACES WHERE SPACE IS TIGHT. SHEET METAL CONTRACTOR SHALL HAVE PRIORITY OVER OTHER MECHANICAL TRADES IN CEILING SPACE WHERE CONFLICTS OCCUR. 7. ALL PIPING & DUCTWORK SHOWN IS SCHEMATIC, CONTRACTOR SHALL PROVIDE ALL OFFSETS /ELBOWS AS REQ'D TO ALLOW ROUTING AROUND STRUCTURE, ELECTRICAL, & OTHER INTERFERENCES. & FLEXIBLE DUCT LENGTH SHALL NOT EXCEED 8 FEET, AND MAY ONLY BE USED WHERE SPECIFICALLY SHOWN ON THE PLANS. 9. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE & SELECT FINAL LOCATIONS OF ALL AIR INLETS /OUTLETS. SHIFT AIR INLETS/ OUTLETS FROM LOCATIONS SHOWN AS REQ'D TO AVOID CONFLICTS W/ STRUCTURE, LIGHTS, & OTHER ITEMS. SUCH SHIFTS SHALL MAINTAIN SYMMETRY OF AIR TERMINALS & SHALL HAVE PRIOR APPROVAL OF ARCHITECT /ENGINEER. 10. FOR HVAC EQUIP. CURBS AND SUPPORTS, SEE DETAILS 4,5, AND 6 SHEET M4.2. 11.. PROVIDE MANUAL VOLUME DAMPERS IN ALL BRANCH DUCTS AND SPLITS IN MAIN DUCTS AND WHERE REQ'D BY BALANCERS; ONLY SOME OF THE REQ'D DAMPERS ARE SHOWN ON THE PLANS. 12. UNSIZED DUCTS SHALL MATCH THE SIZE OF THE LARGEST ADJACENT DUCT THAT IS SIZED. WHERE THE ADJACENT DUCT SIZE -IS NOT SHOWN, PROVIDE THE FOLLOWING SIZED DUCTS (OR EQUIVALENT RECTANGULAR). CFM DUCTS TO AIR OTHER INLETS /OUTLETS DUCT 0 - 100 6" 0 6" 0 101 - 150 8" o 8" 0 151 - 250 10 " o 8" 0 ' 251 - 400 12" 0 10" o 401 - 500 14" 0 12" 0 501 - 700 16" 0 12" 0 701 - 900 18" o 14" 0 901 - 1200 20" 0 16" 0 1201 - 1500 - - -- 18" 0 13. VERIFY LOCATIONS OF ITEMS INSTALLED IN CEILINGS WITH ARCHITECTURAL REFLECTED CEILING PLANS PRIOR TO BEGINNING WORK. NOTIFY ARCHITECT OF DISCREPANCIES. 14. MECHANICAL EQUIPMENT 1/2 HP AND LESS SHALL HAVE ANY REQUIRED STARTER /CONTROL RELAY PROVIDED BY SECTION 15900 (EXCEPT WHERE SPECIFICALLY SHOWN OR SPECIFIED OTHERWISE). 15. UNSIZED PLUMBING PIPING SHALL MATCH THE SIZE OF THE LARGEST ADJACENT CONNECTING PIPE SIZE SHOWN, WHERE THE ADJACENT PIPE IS NOT SHOWN (OR NOT CLEAR), THE PIPE SIZE SHALL BE BASED ON THE GPM FLOWING IN THE PIPE (USE TOTAL OF COILS SERVED FOR HYDRONIC SYSTEM, USE FIXTURE UNITS AND CORRESPONDING GPM PER THE UPC FOR DOMESTIC WATER SYSTEMS, USE WASTE FIXTURE UNITS & UPC TABLES FOR WASTE /VENT SYSTEM), AND A VELOCITY NO GREATER THAN 4 FEET PER SECOND. USE UPC CURVES FOR GPM /VELOCITY FOR APPROPRIATE PIPING MATERIAL INVOLVED. 16. PROVIDE SHUT -OFF VALVES ON ALL BRANCH CW & HW LINES. ONLY SOME OF THE REQUIRED VALVES ARE SHOWN. PLUMBING FIXTURE SCHEDULE SYMBOL DESCRIPTION W V CW HW REMARKS P -1A WATER CLOSET 4" 2" 1" - WALL MOUNT- HANDICAP P -3A LAVATORY 2" 1 -1/2" 1/2" 1/2" HANDICAP ACCESSIBLE P -36 HAND SINK 2" 1 -1/2" 1/2" 1/2" WALL MOUNT P -5A PREP' SINK 2" 1 -1/2" 1/2" 1/2" SINGLE 'COMPARTMENT P -5B DISH SINK (3)2" - (2) 1/290 (2) 1 2" THREE COMPARTMENT INDIRECT WASTE P -12A REFRIGERATOR CONNECTION i - 1/2" - GRILLE r o N BLDG RCD It ROUND CEILING KRUEGER RA2 ROUND LOUVERED FACE CAP CAPACITY DIFFUSER ADJUSTABLE CORE RVR ROOF VENT GREENHECK WRH LOW PROFILE LOUVERED CLG CEILING RELIEF PENTHOUSE WSG WALL SUPPLY KRUEGER S580H MECHANICAL LEGEN D OA VENTILATION DESCRIPTION AREA OCCUPANTS OA /PERSON WASTE OR SOIL (W) CLASSROOMS 30 /ROOM 15 CFM AND MODEL NUMBER MEETINGS 5 20 CFM CEILING COMMONS 50 15 CFM APPROXIMATELY ENERGY CODE REQUIREMENTS: A. THERMOSTAT /TIME CLOCK CONTROL SHALL BE PROVIDED. SYSTEM SHALL PROVIDE 365 CRG DAY CONTROL OF ALL EQUIPMENT (SEE SPEC SEC 15900). B. ALL HVAC UNITS SHALL HAVE 100% OA CAPABLE ECONOMIZERS UNLESS NOTED. 1 /2 "x1 /2 "x1 /2" CUBE CORE CONTROLS SHALL EVALUATE OA TEMP TO ALLOW FOR ECONOMIZER OPERATION. C. DUCTWORK SHALL BE SEALED IN ACCORDANCE W/ CODE, & PER SPECIFICATION N REQIREMENTS (SEE SPEC SECTION 15840). D. DUCT INSULATION R -VALUE SHALL BE IN ACCORDANCE W/ CODE, & PER CEILING EXH. SPECIFICATION REQUIREMENTS. (SEE SPEC SECTION 15250) E. PIPE INSULATION R -VALUE SHALL BE IN ACCORDANCE W/ CODE, BOTTOM OF DUCT & PER SPECIFICATION REQUIREMENTS. (SEE SPEC SECTION 15250) F. MOTORS 1 HP & LARGER SHALL BE ENERGY EFFICIENT TYPE, IN ACCORDANCE W/ CODE. MECHANICAL LEGEN D AIR INLET & OUTLET SCHEDULE DESCRIPTION ABBREV. DESCRIPTION MANUFACTURER WASTE OR SOIL (W) SYMBOL ABOVE FINISHED FLOOR TYPE AND MODEL NUMBER REMARKS CD CEILING KRUEGER SERIES SH LOUVER FACE, SQUARE NECK W/ STRAIGHTENING GRID APPROX APPROXIMATELY DIFFUSER mN E ARCH CRG m v 7 CEILING RETURN KRUEGER SERIES EGC -5 1 /2 "x1 /2 "x1 /2" CUBE CORE AUTO AUTOMATIC GRILLE N AAV CEG o C), CEILING EXH. KRUEGER SERIES EGC -5 1 /2 "x1 /2 "x1 /2" CUBE CORE B.O.D. BOTTOM OF DUCT GRILLE BTU TG TRANSFER KRUEGER SERIES EGC -5 1 /2 "x1 /2 "x1 /2" CUBE CORE BTUH BRITISH THERMAL UNIT /HOUR GRILLE r o N BLDG RCD It ROUND CEILING KRUEGER RA2 ROUND LOUVERED FACE CAP CAPACITY DIFFUSER ADJUSTABLE CORE RVR ROOF VENT GREENHECK WRH LOW PROFILE LOUVERED CLG CEILING RELIEF PENTHOUSE WSG WALL SUPPLY KRUEGER S580H HORIZ. FACE BARS 3/4" COP COMP COEFFICIENT OF PERFORMANCE COMPRESSOR GRILLE - -- O.C., 35' DEFLECTION AIR INLET & OUTLET SCHEDULE NOTES: 1. CEILING DIFFUSERS (CD) SHALL HAVE NO. & DIRECTION OF THROWS AS INDICATED ON PLANS. (E.G. CD -3 = 3 WAY THROW) 2. ALL AIR TERMINALS SHALL HAVE FACTORY FINISH, COLOR AS SELECTED BY ARCHITECT. 3. SEE LEGEND FOR TERMINOLOGY USED IN AIR TERMINAL CALL -OUTS ON DRAWINGS. 4. SEE ARCH. FINISH SCHEDULE FOR CEILING TYPES, PROVIDE AIR TERMINALS TO MATCH CEILING CONSTRUCTION INSTALLED IN. 5. SEE SECTION 15870 FOR SPECIFICATIONS. MECHANICAL LEGEN D SYMBOL DESCRIPTION ABBREV. DESCRIPTION a 0 WASTE OR SOIL (W) AFF ABOVE FINISHED FLOOR •N N AHJ AUTHORITY HAVING JURISDICTION rcl - - - - - - VENT (V) APPROX APPROXIMATELY ti mN E ARCH ARCHITECTURAL m v 7 � - COLD WATER (CW) AUTO AUTOMATIC .2 3 N AAV AUTOMATIC AIR VENT o C), bM -- HOT WATER (HW) B.O.D. BOTTOM OF DUCT BTU BRITISH THERMAL UNIT Z am -- HOT WATER CIRCULATING (HWC) BTUH BRITISH THERMAL UNIT /HOUR G r o N BLDG BUILDING It RG REFRIGERANT GAS CAP CAPACITY CH CHR CHILLED WATER SUPPLY CHILLED WATER RETURN RL REFRIGERANT LIQUID CLG CEILING CO CLEANOUT GATE TYPE EXCEPT WHERE INDICATED TO BE Q ISOLATION VALVE A DIFFERENT TYPE - SEE DETAILS & SPECS COP COMP COEFFICIENT OF PERFORMANCE COMPRESSOR - -- ->t:l- GLOBE CONN CONT CONNECTION CONTINUE, CONTINUATION - -�Oi -- BALL VALVE CFM CT CUBIC FEET PER MINUTE CLOSED TRANSITION ANGLE VALVE CW DEC F, F COLD WATER DEGREE FAHRENHEIT DKF- COMBINATION SHUT -OFF & BALANCING VALVE DIA, ff DN DIAMETER DOWN CHECK VALVE DWG DB DRAWING DRY BULB -- -1�'1- BUTTERFLY VALVE DL EA DOOR LOUVER EACH <y -il�- UNION EFF ELEC EFFICIENCY ELECTRICAL, ELECTRIC RELIEF VALVE OR SAFETY VALVE EER EAT ENERGY EFFICIENCY RATIO ENTERING AIR TEMPERATURE Q MANUAL AIR VENT EWB EDB ENTERING WET BULB ENTERING DRY BULB STRAINER EOL EXH END OF LINING EXHAUST CONCENTRIC REDUCER EXIST EXISTING HOSE BIBB ESP EXTERNAL STATIC PRESSURE F FV FIRE FACE VELOCITY P.D.I.'A' WATER HAMMER ARRESTOR P.D.I. SIZE AS SHOWN FPM FEET PER MINUTE _ i' PRESSURE GAUGE FLEX FLEXIBLE FL FLOOR THERMOMETER FCO FLOOR CLEAN OUT FLA GAL FULL LOAD AMPS GALLON 20/12 DUCT (FIRST FIGURE, SIDE SHOWN) GALV. HP GALVANIZED HORSE POWER 20/12L* LINED DUCT (DIM. FOR NET FREE AREA) EOL= END OF LINING HW HWC HOT WATER HOT WATER CIRCULATION - Rs� RISE (R) OR DROP (D) ARROW IN DIRECTION OF FLOW HWS HWR HOT WATER SUPPLY HOT WATER RETURN DUCT SECTION (SUPPLY) INTEGR. IN INTEGRAL INCH DUCT SECTION (EXHAUST OR RETURN) I.E. KW INVERT ELEVATION KILOWATT _ 0 ROUND DUCT LAT LDB LEAVING AIR TEMPERATURE LEAVING DRY BULB VOLUME DAMPER (MANUAL) LWT LWB LEAVING WATER TEMPERATURE LEAVING WET BULB MOTORIZED DAMPER MFR MAX MANUFACTURER MAXIMUM FLEXIBLE CONNECTION MBH THOUSAND BTUH COMBINATION FIRE /SMOKE DAMPER MECH MECHANICAL MIN MINIMUM �7�JZl1I' FLEXIBLE DUCT MCA MINIMUM CIRCUIT AMPS MUA NO MAKE UP AIR NORMALLY OPEN 17= ELBOW W /TURNING VANES NC NO. NORMALLY CLOSED NUMBER slzE,sYMBOL ® CEILING OUTLET (WHERE 2 CFM'S SHOWN, 1st = HIGH SPEED CFM 2nd = LOW SPEED CFM) NTS OBD NOT TO SCALE OPPOSED BLADE DAMPER Z sIZE,SYMBOL CEILING INLET CFM OA OUTSIDE AIR SIZE ,SYMBOL WALL OUTLET (OR INLET) PH PHASE P.D.I. PD PLUMBING AND DRAINAGE INST. PRESSURE DROP O QOA THERMOSTAT G= WITH GUARD (D A= AVERAGED NTH OTHER R RLA RETURN RATED LOAD AMPS O SWITCH REF REFERENCE 2 DETAIL IDENTIFICATION NUMBER REQ'D REQUIRED SHEET ON WHICH DETAIL IS SHOWN RA RETURN AIR M3. RPM REVOLUTIONS PER MINUTE RM RG ROOM REFRIGERANT GAS A SECTION IDENTIFICATION LETTER RL REFRIGERANT LIQUID SHEET ON WHICH SECTION IS SHOWN S SUPPLY SA SUPPLY AIR SCO SURFACE CLEANOUT S.O. SCREENED OPENING SQ FT SQUARE FOOT TEMP TEMPERATURE TD TRANSFER DUCT TG TRANSFER GRILLE TYP TYPICAL UNO UNLESS NOTED OTHERWISE VTR VENT THROUGH ROOF V VOLTS, VOLTAGE, VENT WCO WALL CLEAN OUT W WASTE WA WATT WB WET BULB W/ WITH I.' W W V J 1 0 J = Q U C,.) Z Z w U w CW ii­- 7 cz N W z W 0 U0 r .. Z u 0 0 �- Z f - F-- 0 QZ t= U Z:) Q � fV n Z W 0 U O J W J Lu >_ >- PROJECT U Z MEK o a 0 i W M O •N N rcl v ti mN E rC'j m v 7 � � Y z V) r v .2 3 N o C), bM C� a a O o3'= Z am G r o N 0 It J z Q 0 a, J CL N <y W W V J 1 0 J = Q U C,.) Z Z w U w CW ii­- 7 cz N W z W 0 U0 r .. Z u 0 0 �- Z f - F-- 0 QZ t= U Z:) Q � fV n Z W 0 U O J W J Lu >_ >- PROJECT U 0inN N MEK DATE MI i W M O N v ti mN E G m v 7 � � Y z V) v N4� N bM M a' C a s - o3'= Z am G r o N 0 It J W W V J 1 0 J = Q U C,.) Z Z w U w CW ii­- 7 cz N W z W 0 U0 r .. Z u 0 0 �- Z f - F-- 0 QZ t= U Z:) Q � fV n Z W 0 U O J W J Lu >_ >- PROJECT 21049 DRAWN: MEK DATE 3/27/02 SHEET M0.1 :SIN E UNFINISHED AREA (FUTURE EXPANSION) m RL 80 V V r —� I i I I I I L J E)AC -1 B ON ROOF I -- a---- - - - - -- NORTH I� ll WOMEN UP TO (E) EF -3 ON ROOF - - - -- UP TO (E) HVAC -4 ON ROOF O �1 n 1 UZD I I IUP ON ROOF UP TO (E)HVAC -3 ON ROOF TO (E) FLOOR PLAN - MECHANICAL DEMOLITION 1/811 = 1' -0" GENERAL DEMOLITION NOTES UP TO (E)EF -1 ON ROOF 1. DEMOLITION DRAWINGS ARE INTENDED TO ONLY GIVE A GENERAL REPRESENTATION OF THE DEMOLITION INVOLVED, AND DO NOT CONSTITUTE A FULL LISTING 8. EXIST. DUCTS, AIR INLETS /OUTLETS, PLUMBING FIXTURES SHOWN DASHED REPRESENT (J OF ALL ITEMS. 21049 MAJOR MECHANICAL ITEMS TO BE REMOVED. SEE NOTES AND BUBBLE NOTES WHICH 2. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW SITE CONDITIONS AND TO IDENTIFY 3/27/02 COVER ALL OTHER MISCELLANEOUS MECHANICAL ITEMS TO BE REMOVED. u ALL DEMOLITION WORK AND INCLUDE IN HIS BID ALL COSTS FOR DEMOLITION. 9. SEE MECHANICAL FLOOR PLANS FOR HVAC DUCTS THAT ARE BEING REUSED. 3. CONTRACTOR SHALL VERIFY THE LOCATIONS & CONNECTIONS OF ALL ITEMS NOTED TO BE DEMOLITIONED. 10. WHERE EXIST. DUCTS ARE REUSED, AND EXIST. BRANCH DUCTS ARE REMOVED, PROVIDE SHEET METAL PATCH WITH INSULATION AT UNUSED CONNECTION (INSULATION REQUIRED ON SUPPLY AIR DUCTS ONLY). 4. ALL EXIST. ITEMS NOT BEING REUSED SHALL BE REMOVED. THIS INCLUDES SUCH ITEMS O O AS THERMOSTATS, CONTROL DEVICES, DUCTS, FANS, PIPING, GRILLES, SUPPORTS, 11. HOLD ALL REMOVED ITEMS FOR OWNERS REVIEW. ITEMS SELECTED BY OWNER FOR VALVES, CURBS, AND RELATED ACCESSORIES. SALVAGE SHALL BE MOVED BY THE CONTRACTOR TO THE OWNERS STORAGE ROOM 5. ABANDONED ITEMS, ANCHORS, INSERTS, PIPE STUBS, AND OTHER PROJECTIONS NOT (VERIFY EXACT LOCATION WITH OWNER). ITEMS NOT SELECTED BY OWNER FOR SALVAGE SHALL BE DISPOSED OF OFF SITE BY CONTRACTOR. BEING CONCEALED BY NEW CONSTRUCTION SHALL BE REMOVED TO 1" BELOW THE N ADJACENT FINISHED SURFACE, AND THE DISTURBED AREA PATCHED. 6. PATCH ALL WALL /FLOOR /CEILING OPENINGS LEFT BY REMOVAL OF EXIST. ITEMS. PATCH SO AS TO MATCH FINISH OF ADJACENT UNDISTURBED AREA. 7. REFERENCE ARCHITECTURAL DRAWINGS FOR WHERE CEILING /WALL AND OTHER GENERAL DEMOLITION WORK IS BEING DONE. KEYED NOTES: �1 EXIST UNIT TO REMAIN. 2O REMOVE EXIST DIFFUSER AND REUSE AT NEW LOCATION. SEE FLOOR PLAN M4.1. O3 REMOVE EXIST DUCTWORK AND ASSOCIATED ACCESSORIES. FOR NEW DUCTWORK SEE FLOOR PLAN M4.1. U Q Z QO CL r J 00 0:2 W � Q N W Il'— L40') Z --1 WO U0 .. Z U 00C/) 0Qz F- U Q�� IV 0 zWO Ez W 0 —� W J >— >— cxr 11�!: - 0-4 - I CT (J PROJECT 21049 EV N v E W) , O 0 3/27/02 u C4 O r-- U CD o 0 E O O N A a, V � a t 5 � v � U a > "' 0 a +-' 4I U t; 3 r s c 0 E v Q U Q Z QO CL r J 00 0:2 W � Q N W Il'— L40') Z --1 WO U0 .. Z U 00C/) 0Qz F- U Q�� IV 0 zWO Ez W 0 —� W J >— >— cxr 11�!: - 0-4 - I PROJECT 21049 DRAWN: MEK DATE 3/27/02 SHEET M1.1 Ns UP TO FC0 2 "V UP W (E)4 � O4 "W La) r"Al M (E)4 "W 1777') L: i, rr) (E) WATER METER IN VAULT FOUNDATION PLAN --PLUMBING 1/8" = F-0" i i 5 GENERAL NOTES: 1. SEE STRUCTURAL DRAWINGS FOR LOCATIONS /VARIATIONS OF FOUNDATION COMPONENTS SHOWN ON THIS DRAWING. 2. INVERT ELEVATIONS ARE BASED ON A FINISHED FLOOR ELEVATION OF 0.0 FEET. 3. PATCH ALL WALL /FLOOR /CEILING OPENINGS AFTER INSTALLING NEW PIPES IN EXIST STRUCTURE. 4. SAWCUT CONCRETE TO INSTALL ALL NEW BELOW GRADE PLUMBING. KEYED NOTES: �1 VERIFY DEPTH OF (E) WASTE LINE PRIOR TO INSTALLING ANY WASTE PIING. O2 SAW CUT EXISTING SLAB TO INSTALL NEW WASTE LINE. U z Fr i I p P E U I I I I I , � � O vD W p f (E) WATER METER IN VAULT FOUNDATION PLAN --PLUMBING 1/8" = F-0" i i 5 GENERAL NOTES: 1. SEE STRUCTURAL DRAWINGS FOR LOCATIONS /VARIATIONS OF FOUNDATION COMPONENTS SHOWN ON THIS DRAWING. 2. INVERT ELEVATIONS ARE BASED ON A FINISHED FLOOR ELEVATION OF 0.0 FEET. 3. PATCH ALL WALL /FLOOR /CEILING OPENINGS AFTER INSTALLING NEW PIPES IN EXIST STRUCTURE. 4. SAWCUT CONCRETE TO INSTALL ALL NEW BELOW GRADE PLUMBING. KEYED NOTES: �1 VERIFY DEPTH OF (E) WASTE LINE PRIOR TO INSTALLING ANY WASTE PIING. O2 SAW CUT EXISTING SLAB TO INSTALL NEW WASTE LINE. V Z m �G. J IL Z Q _J CL z 0 1- Q Q Z) 0 ce N W* Z v' J (W O i V O .. Z U I­ O z 0Qz 1= U Q�� IV Q zW0 W U 0 �E � � G W WRES 88 -14-03 PROJECT 21049 DRAWN: MEK DATE 3/27/02 SHEET M2.1 U z p P E U _N rt I � � O vD W p p ai f�V N v � m v E _c) O v (c� O O O O N U GC 0) U C 4. = • N °3= N Z C; r � r y C 0 0 OU I Q N F�- Qj U a y1 � � y }.j p N a < ° o E v W�o� V Z m �G. J IL Z Q _J CL z 0 1- Q Q Z) 0 ce N W* Z v' J (W O i V O .. Z U I­ O z 0Qz 1= U Q�� IV Q zW0 W U 0 �E � � G W WRES 88 -14-03 PROJECT 21049 DRAWN: MEK DATE 3/27/02 SHEET M2.1 U 0 if) _N rt I � � O vi 7 M v � m v E +~ v I Z ul �o N GC 0) U C 4. = °3= Z C; r � r y C 0 0 OU I N F�- V Z m �G. J IL Z Q _J CL z 0 1- Q Q Z) 0 ce N W* Z v' J (W O i V O .. Z U I­ O z 0Qz 1= U Q�� IV Q zW0 W U 0 �E � � G W WRES 88 -14-03 PROJECT 21049 DRAWN: MEK DATE 3/27/02 SHEET M2.1 �E) UNFINISHED AREA (FUTURE EXPANSION) G i ,--(E)2"CW �n RECEPTION 002 I� �u I I,� _ JL.I \VLI \I VVJ� -, I I P -5113 MEETING ! go, - 1. PROVIDE WALL CLEANOUT BENEATH SINK FOR ALL COUNTER AND LUNCH < o WALL MOUNTED SINKS. U N 3 o 2. FOR PIPING SIZES TO INDIVIDUAL PLUMBING FIXTURES, SEE � 3 o WORK "PLUMBING FIXTURE SCHEDULE" SHEET M1 1 w N ° � ( 1/2" "CW IN LIEU OF THE DESIGN SHOWN (REFERENCE FOUNDATION PLANS). PROVIDE END -OF -LINE CLEANOUTS TO PROVIDE CLEANOUT oo in N _ E)1 N M i P -12A I l - E)1 /2 "HWC - (E)4 "VTR BUILDING THAT IS BEING DEMOLISHED. REVISE BRANCH JAN. /MECH. LINES AS REQUIRED TO MAINTAIN SPRINKLERING OF N E EXISTING BUILDING. L 005 m-- � r. V) -- -- STOP AT SINK ROUGH -INS. STAFF E��oB N o CN b M 00 i ,_ E)2 1 "CW o � � Zom 1/2"HW r 0 y P -3A MEN d 0 KEYED NOTES: L "Fa 1 � (E)2 "CW, 1- 1 /4 "HW CONN TO (E)2 "CW-/ EXIST (TYP) T-, G i ,--(E)2"CW �n RECEPTION 002 I� �u I I,� _ - I ,` �n 3. ALL ISOLATION VALVES SHALL BE ACCESSIBLE. PLUMBING NORTH nl - ( ( I - == (E) 3" FLOOR SINK f RECEIVING STORAGE WOMEN - - -- - - - -? 015 � ppqq 010 I u - A -P-5A - -- _ ----- - - - --� CLASSROOM I �_ G -- - - -- - - -� 013 ; - - - -- -- - - - „ -- '±-- — - -- (E) 2 _ AFt IL�L� G iHVAC -5i 14 "G ------ FLOOR PLAN - PLUMBING 1/81, = 1' -0" CLASSROOM 019 I — I _ i CLASSROOM 016 -- (E)3/4" HVAC -21 ----------- (K) ------------------------ ---------- ----(C ) I U I I i , ---------------------- I---- - - - - --- i i i ---------------- - - - - -- I , i z lu t 0 z 0 GENERAL NOTES: , . . 3. ALL ISOLATION VALVES SHALL BE ACCESSIBLE. PLUMBING go, 1. PROVIDE WALL CLEANOUT BENEATH SINK FOR ALL COUNTER AND o < o WALL MOUNTED SINKS. U N 3 o 2. FOR PIPING SIZES TO INDIVIDUAL PLUMBING FIXTURES, SEE � 3 o o "PLUMBING FIXTURE SCHEDULE" SHEET M1 1 w N ° 0 PIPE HW DIN IN CHASE TO WITHIN 5' OF LAVATORIES. V Z m n.. Z C Oe 0 0 � � P tT w U N N o U C? C� O � In d L V r- V L w (N W H C/) Z w0 U0 .. Z U �I O p � OQZ U 5� Q IV 0 Z L_LJ 0 w U 0 w uj PROJECT 21049 DRAWN: MEK DATE 3/27/02 SHEET M3.1 OF: , . . 3. ALL ISOLATION VALVES SHALL BE ACCESSIBLE. PLUMBING CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO INSURE VALVES ARE ACCESSIBLE. PROVIDE ACCESS DOORS AS SPECIFIED. " 4. OFFSET VTR'S AND PIPING AS REQUIRED TO AVOID DUCTWORK AND " OTHER OBSTRUCTIONS. 5. AT MAIN RESTROOMS, CONTRACTOR MAY USE HORIZONTAL DISCHARGE WASTE CARRIERS AND ABOVE FLOOR WASTE PIPING IN LIEU OF THE DESIGN SHOWN (REFERENCE FOUNDATION PLANS). PROVIDE END -OF -LINE CLEANOUTS TO PROVIDE CLEANOUT oo in N ACCESS EQUAL TO DESIGN. [ N M i 6. CAP FIRE MAINS SERVING THE PORTION OF THE EXISTING x y n BUILDING THAT IS BEING DEMOLISHED. REVISE BRANCH LINES AS REQUIRED TO MAINTAIN SPRINKLERING OF N E EXISTING BUILDING. L 7. PROVIDE CAPPED WASTE STUBOUT, HW STOP, AND CW � r. V) STOP AT SINK ROUGH -INS. v N o CN b M 00 [ c L o � Zom C I r 0 y O d 0 KEYED NOTES: "Fa 0 PIPE HW DIN IN CHASE TO WITHIN 5' OF LAVATORIES. V Z m n.. Z C Oe 0 0 � � P tT w U N N o U C? C� O � In d L V r- V L w (N W H C/) Z w0 U0 .. Z U �I O p � OQZ U 5� Q IV 0 Z L_LJ 0 w U 0 w uj PROJECT 21049 DRAWN: MEK DATE 3/27/02 SHEET M3.1 OF: E {' UNFINISHED AREA (FUTURE EXPANSION) m �1-- - �---�- -'� 5 �__ `-q � -10/4 DN (TYP) 12 10 12/10_, ANGE HOOD (TYP) z1 22x10 TG 0 ,� o � MEETING 017 C� 4 1 N COMMONS O - 022 16"0 22x22 CRG 1030 _C 24/28L i (E) 16" RCD UP TO HVAC -1 i i 1000 (TYP. 2) `• �_ -- ON ROOF J d- ..M - -- UP TO (E) HVAC -3 UP TO HVAC -5 - -- r- - - - -_, ON ROOF HALL UP TO HVAC -2 UP TO HVAC -4 ON ROOFO I I 022E ON %ROOF L_ _ 8 0 -�� I 120 CFM L - ON ROOF i 16 "0 i t 1120 CFM OFFICE 001 12x8 CONN 10 "0 12X12 EDH_2 TG TO EXIST CD -4�- _ . i 10/10 i i i i i 9 8 7 6 5 NORTH O - - �,.. 6x6 CD -2 8x8 w CONN TO r - - -� 100 8/4 CRG EXIST (TYP) + -j 95 ` Q 6 "0 AV STORAGE 018 I - -- 22x22 CRG 2 18L G (E)22/12L 750 � - { i CONN TO (E)FIRE DAMPER EXIST (TYP) 20/10L I ) / 22x22 CEG 1202 CD-4 00 (TYP 4 12/8 I EDH -1 j CLASSROOM 12/8 12 "0 (TYP) 019 4 IF 8 "0(TYP i FLOOR PLAN - HVAC 1 /8" = 1 ' -0" i i U ----- - - - - -_ GENERAL NOTES: 1. LOCATE MOTORIZED DAMPERS AND DUCT HEATERS TO BE ACCESSIBLE. 2. CFM'S SHOWN REPRESENT AIRFLOWS WITH SYSTEM IN "OCCUPIED" MODE. 3. VERIFY MOUNTING HEIGHTS OF ALL EXPOSED DUCTWORK & WALL GRILLES /WALL CAPS W/ ARCHITECT PRIOR TO BEGINNING WORK. 4. PROVIDE TRANSITIONS AT DUCT CONNECTIONS TO ALL COILS, FANS & OTHER EQUIPMENT TO MATCH UNIT CONNECTIONS. TRANSITIONS SHALL BE LINED WHERE CONNECTING DUCTS ARE LINED. 5. WHERE ROUND BRANCH DUCTS CONNECT TO ROUND OR RECTANGULAR DUCTS PROVIDE CONICAL CONNECTIONS (EXCEPT FOR BRANCH DIFFUSER DUCTS WHERE SPIN -IN FITTINGS ARE USED). WHERE RECTANGULAR BRANCH DUCTS CONNECT TO RECTANGULAR DUCTS PROVIDE 45' FLARED CONNECTIONS. WHERE RECTANGULAR DUCTS CONNECT TO ROUND DUCTS, PROVIDE A CONICAL ROUND CONN & TRANSITION FROM ROUND TO RECTANGULAR. 6. PROVIDE ACCESS DOORS IN CEILING /SOFFITS TO ALL DUCT COILS, DAMPERS, FANS & SIMILAR ITEMS REQUIRING ACCESS. CLASSROOM 016 - — - — - — --- (a) i i I - - - - -- ----- - - - - -� �. i i I i i i J KEYED NOTES: O1 PROVIDE LINED TRANSITION FROM DUCT SIZE SHOWN TO MATCH UNIT SIZE. O 12X12 TG WITH 12X10L TRANSFER DUCT. 03 BALANCE CFM FROM EXISTING UNIT AS SHOWN. 04 EXISTING RELOCATED CEILING DIFFUSER, BALANCE CFM AS SHOWN. O5 22x22 TG WITH 20/8L TRANSFER DUCT. u 0r-N N C: z U V 17 OM � U roNet/7 z U Oa>- A J Q L=J Q.i • O tj 2 .. Il 0 > ,. O U N IV 0 r oo rj OD ; 0) v rn C) o E i I U � � zom J w -' r E\ t, iI v ee� UP TO (E)EF -1 I ON ROOF -------- ---i�1 M _ N RECEIVING STORAGE 015 R /SCIENCE /PE z r- i i 014 Q L._J CD , O O 9x9 -1 150 . � a — ' -- - -- � 18/14L LE L J y 3 d o in E o nnn L J d- ..M - -- UP TO (E) HVAC -3 UP TO HVAC -5 - -- r- - - - -_, ON ROOF HALL UP TO HVAC -2 UP TO HVAC -4 ON ROOFO I I 022E ON %ROOF L_ _ 8 0 -�� I 120 CFM L - ON ROOF i 16 "0 i t 1120 CFM OFFICE 001 12x8 CONN 10 "0 12X12 EDH_2 TG TO EXIST CD -4�- _ . i 10/10 i i i i i 9 8 7 6 5 NORTH O - - �,.. 6x6 CD -2 8x8 w CONN TO r - - -� 100 8/4 CRG EXIST (TYP) + -j 95 ` Q 6 "0 AV STORAGE 018 I - -- 22x22 CRG 2 18L G (E)22/12L 750 � - { i CONN TO (E)FIRE DAMPER EXIST (TYP) 20/10L I ) / 22x22 CEG 1202 CD-4 00 (TYP 4 12/8 I EDH -1 j CLASSROOM 12/8 12 "0 (TYP) 019 4 IF 8 "0(TYP i FLOOR PLAN - HVAC 1 /8" = 1 ' -0" i i U ----- - - - - -_ GENERAL NOTES: 1. LOCATE MOTORIZED DAMPERS AND DUCT HEATERS TO BE ACCESSIBLE. 2. CFM'S SHOWN REPRESENT AIRFLOWS WITH SYSTEM IN "OCCUPIED" MODE. 3. VERIFY MOUNTING HEIGHTS OF ALL EXPOSED DUCTWORK & WALL GRILLES /WALL CAPS W/ ARCHITECT PRIOR TO BEGINNING WORK. 4. PROVIDE TRANSITIONS AT DUCT CONNECTIONS TO ALL COILS, FANS & OTHER EQUIPMENT TO MATCH UNIT CONNECTIONS. TRANSITIONS SHALL BE LINED WHERE CONNECTING DUCTS ARE LINED. 5. WHERE ROUND BRANCH DUCTS CONNECT TO ROUND OR RECTANGULAR DUCTS PROVIDE CONICAL CONNECTIONS (EXCEPT FOR BRANCH DIFFUSER DUCTS WHERE SPIN -IN FITTINGS ARE USED). WHERE RECTANGULAR BRANCH DUCTS CONNECT TO RECTANGULAR DUCTS PROVIDE 45' FLARED CONNECTIONS. WHERE RECTANGULAR DUCTS CONNECT TO ROUND DUCTS, PROVIDE A CONICAL ROUND CONN & TRANSITION FROM ROUND TO RECTANGULAR. 6. PROVIDE ACCESS DOORS IN CEILING /SOFFITS TO ALL DUCT COILS, DAMPERS, FANS & SIMILAR ITEMS REQUIRING ACCESS. CLASSROOM 016 - — - — - — --- (a) i i I - - - - -- ----- - - - - -� �. i i I i i i J KEYED NOTES: O1 PROVIDE LINED TRANSITION FROM DUCT SIZE SHOWN TO MATCH UNIT SIZE. O 12X12 TG WITH 12X10L TRANSFER DUCT. 03 BALANCE CFM FROM EXISTING UNIT AS SHOWN. 04 EXISTING RELOCATED CEILING DIFFUSER, BALANCE CFM AS SHOWN. O5 22x22 TG WITH 20/8L TRANSFER DUCT. u 0r-N N C: N U V 17 OM � U .. z U Oa>- A J 4' .0 z1�-� F� .. Il 0 � �I N IV 0 r oo rj OD ; 0) v rn uJ 0 ic U � zom J w -' r E\ 0 r 0�_ o v U Q s z d 0 0 EXQIRES 8 -1403 PROJECT 21049 DRAWN: MEK DATE 3/27/02 SHEET M OF: w N W U w0 U .. z U Oa>- z1�-� 0Qz �_UZ:) Q::) :�i IV 0 12 Z uJ 0 w U � 0 J w -' EXQIRES 8 -1403 PROJECT 21049 DRAWN: MEK DATE 3/27/02 SHEET M OF: EXTEND DUCT UP TO TOP OF CURB, SEAL AT BOTH SIDES OF DUCT BACKDRAFT DAMPER, ANCHOR TO CURB & DUCT, 12" O.C. TRANSITION AS NECESSARY TO SUIT FAN DAMPER & CURB SIZE DUCT SIZE PER PLAN ROOF FAN MOUNTING DETAII 1-1/2$1=10-019 DDC CONTROLLER TO FMCS TO ROOM ' SENSOR i DUCT SIZE PER \ ACTUATOR PLAN (TYP) \ / 2x DAMPER DIA i 2x DAMPER DIA MIN hm MIN / AIR I \ FLOW � I � I � CHANGE -OVER TEMP SENSOR TRANSITION ZONE DAMPER, SIZE PER PLAN ZONE DAMPER DETAIL K__3 �.2 NOT TO SCALE 1, n. 2 EXTEND DUCT UP TO TOP OF CURB, SEAL AT BOTH SIDES OF DUCT BACKDRAFT DAMPER, ANCHOR TO CURB & DUCT, 12" O.C. TRANSITION AS NECESSARY TO SUIT FAN DAMPER & CURB SIZE DUCT SIZE PER PLAN ROOF VENT MOUNTING DETAIL 1-1/2"=l'-o" PROVIDE ADDED ELBOWS/ OFFSETS /FIRE DAMPERS AS MAY BE SHOWN ON PLAN i z - — — — — — — — — — — I ~' w I I I I L - - -J z a J CL af w d w N TRANSFER DUCT NOT TO SCALE 20 GA. S.S. FLASHING, FASTEN TO NAILER AT TOP 3" MIN. HEIGHT HOLD —DOWN STRAP, 2" WIDE x 16 GAUGE GALV. STEEL, FASTEN WITH (3) #10 S.M. SCREWS TO UNIT & CURB (TYP. 4 PLACES). ROOFING, SEE ARCHITECHTURAL PLANS ............ ............. ............... ................ .................. ................... ..................... RIGID FOAM INSULATION (OR WOOD CANT) TAPERED TO ALLOW ROOF DRAINAGE AWAY FROM UNIT AREA HVAC UNIT SOUND -LINED DUCT, SIZE PER PLAN. WHERE SIZE NOT SHOWN MATCH GRILLE SIZE. NET SIZE SHOWN AFTER LINING. V) PARTITION WALL DETAIL J - - - _I- 6 CURB DETAIL. M4.2 NTS FINISHED CEILING CURB, FURNISHED WITH HVAC UNIT RIGID INSULATION ANCHOR CURB TO BEAM W/ 16d, 12" O.C., SEE DETAIL 1 THIS SHEET r4�� M4.2 LEVEL CURB SEE STRUCTURAL PLANS v J a > N C6 o m o � � 3 a •H v v C L � N 0 O u J Q n U Q IMP w V u 0 vle W 01AN NMI mt70 4 M un W v 7 JJ ' Z y 1� 0 N O M � O 031 Z p m E� r0 0« 04F- -I o � U O ®1 � O E v t1') N I � r a v ;q ce N W V) Z —I w0 U O .. Z U 00� Z�F- 0QZ 1= U Q tV Q z uu 0 w U C) Q � J :�E >- >- I m PROJECT 21049 DRAWN: SCR DATE 3/27/02 SHEET M4.2 OF: z Q J a. ~' w IL w N V) PARTITION WALL DETAIL J - - - _I- 6 CURB DETAIL. M4.2 NTS FINISHED CEILING CURB, FURNISHED WITH HVAC UNIT RIGID INSULATION ANCHOR CURB TO BEAM W/ 16d, 12" O.C., SEE DETAIL 1 THIS SHEET r4�� M4.2 LEVEL CURB SEE STRUCTURAL PLANS v J a > N C6 o m o � � 3 a •H v v C L � N 0 O u J Q n U Q IMP w V u 0 vle W 01AN NMI mt70 4 M un W v 7 JJ ' Z y 1� 0 N O M � O 031 Z p m E� r0 0« 04F- -I o � U O ®1 � O E v t1') N I � r a v ;q ce N W V) Z —I w0 U O .. Z U 00� Z�F- 0QZ 1= U Q tV Q z uu 0 w U C) Q � J :�E >- >- I m PROJECT 21049 DRAWN: SCR DATE 3/27/02 SHEET M4.2 OF: ELECTRICAL LEGEND SYMBOL DESCRIPTION 0 LIGHTING OUTLET — CEILING D FLUORESCENT FIXTURE (TO SCALE ON DRAWINGS) 0 RECESSED FIXTURE - ROUND rs SURFACE FIXTURE - WALL ® EXIT FIXTURE - WALL MOUNT WITH DIRECTIONAL ARROWS �A AS INDICATED ON DRAWINGS. �► EMERGENCY FIXTURE - TWIN HEAD A— IDENTIFYING NUMBER FLUORESCENT FIXTURE WITH EMERGENCY LIGHTING UNIT XXX FIXTURE SYMBOL FLUORESCENT FIXTURE - LAY -IN S SINGLE POLE TOGGLE S3 THREE -WAY TOGGLE SK KEY OPERATED SWITCH AND TOP, WHITE ENAMEL FINISH, INDICATES TO PROVIDE ROOM OCCUPANCY SENSOR(S). (SEE DETAIL). OUTLETS KD: DUPLEX RECEPTACLE (NEMA 5 -20R) COMPUTER PURPOSE FOURPLEX RECEPTACLE GFCI DUPLEX RECEPTACLE (NEMA 5 -20R) kcc COMPUTER PURPOSE DUPLEX RECEPTACLE (NEMA 5 -20R) POLYCARBONATE (SEE GENERAL NOTE 2) j ASTERISK INDICATES COUNTER HEIGHT OUTLET � (DUPLEX RECEPTACLE SHOWN) gD:REF REFRIGERATOR RECEPTACLE (NEMA 5 -20R) Q JUNCTION BOX - CEILING -OQ JUNCTION BOX - WALL ® EQUIPMENT CONNECTION O SCHEDULED EQUIPMENT CONNECTION OR SYMBOL F32T8 (INCLUDES FEEDER, DISCONNECT, STARTER, AND OTHER 65/61 REQUIREMENTS AS SCHEDULED) V SIGNAL METALUX GP SERIES TELECOMMUNICATIONS TERMINAL BOARD VOICE (TELEPHONE) OUTLET • OUTLET - COUNTER HEIGHT /P PUBLIC TELEPHONE OUTLET ♦w WALL PHONE OUTLET (+ 54 INCHES) a DATA (COMPUTER) OUTLET WITH JACK FIRE ALARM EAR SYMBOL FOR FIRE ALARM CONTROL PANEL 10 MANUAL STATION HORN WITH VISUAL SIGNAL (STROBE) -�► VISUAL SIGNAL (STROBE) © HEAT DETECTOR <g> SMOKE DETECTOR ® DOOR RELEASE FA CONNECTION DISTRIBUTION AND CIRCUITING PANELBOARD — SURFACE CROSS LINES INDICATE NUMBER OF CONDUCTORS IF BALLAST: ELECTRONIC MORE THAN TWO WIRE CIRCUIT. LONG DENOTES NEUTRAL. DOT DENOTES GROUND. CONDUIT IS 1/2" AND CONDUCTOR IS #12 AWG UNLESS OTHERWISE NOTED OR SCHEDULED. FR2 WIRING CONCEALED IN CEILING OR WALL HOMERUN 120 FLEXIBLE WIRING CONNECTION _t ISOLATED GROUND SYM DESCRIPTION MANUFACTURER LAMP TYPE VOLTS VA /WATTS REMARKS FS1K SURFACE /PENDANT MOUNTED, FAILSAFE FRS SERIES OR F32T8 120 65/61 �A BUBBLE NOTE TAG SYMBOL: 1'X4', 2 —LAMP, RAPID START APPROVED EQUAL A— IDENTIFYING NUMBER ELECTRICAL DEMOLITION FLUORESCENT UNIT, METAL SIDES N � AND TOP, WHITE ENAMEL FINISH, u METAL FRAMED ONE PIECE CLEAR POLYCARBONATE o � BALLAST: ELECTRONIC CD FL2 RECESSED, LAY —IN, 2'X4', 2 —LAMP LITHONIA GT SERIES F32T8 120 65/61 V RAPID START FLUORESCENT STATIC METALUX GP SERIES TROFFER, HINGED POSITIVE LATCH COLUMBIA J SERIES REGRESSED METAL FRAMED ONE N PIECE PRISMATIC TYPE 12 (0.125 INCH THICK) ACRYLIC LENS. BALLAST: ELECTRONIC oo' FR2 SAME AS FL2 EXCEPT WITH F32T8 120 65/61 RECESS PLASTER FRAME OPTION FL3 SAME DESIGN AND MANUFACTURE F32T8 120 100/95 J AS FIXTURE FL2 EXCEPT 3 —LAMP V UNIT ' v, co o. FL5 SAME DESIGN AND MANUFACTURE F31 T8 /U 120 65/61 AS FIXTURE FL2 EXCEPT 2'X2' UNIT 3 .c FW1 WALL MOUNTED, 5.25" X 49 ", FAIL SAFE FWW SERIES F32T8 120 65/61 MOUNT 6" BELOW CLG. 2 —LAMP RAPID START OR APPROVED EQUAL UNLESS OTHERWISE FLUORESCENT UNIT, WHITE ENAMEL Q NOTED METAL HOUSING, WRAP AROUND PRISMATIC ABUSE RESISTANT LENS. UL DAMP LOCATION LABEL. BALLAST: ELECTRONIC FC CABLE SUSPENDED, 2 —LAMP CORELITE NAVIGATOR SERIES F32T8 120 65/61 +10' -0" AFF UNLESS LINEAR FIXTURE WITH CONTINUOUS OTHERWISE NOTED EXTRUDED ALUMINUM HOUSING (UP TO 12 FT) AND CAST ALUMINUM END PLATES. PARABOLIC LOUVER DOWNLIGHT COMPONENT WHITE ENAMEL FINISH WITH A MINIMUM OF 92 % REFLECTANCE. BALLAST: ELECTRONIC R32 RECESSED 8 —INCH DIAMETER PORTFOLIO C7132 F32TT 120 33/26 1 —LAMP COMPACT FLUORESCENT OR APPROVED EQUAL REGRESSED LENS DOWN LIGHT, CLEAR ALZAK LOW IRIDESCENT REFLECTOR LISTED FOR THRU WIRING BALLAST. ELECTRONIC SL2 FLUORESCENT STRIP LIGHT,4', COLUMBIA CS SERIES F32T8 120 65/61 2 —LAMP RAPID START, STANDARD LITHONIA C SERIES CHANNEL. METALUX SS SERIES BALLAST: ELECTRONIC DAY —BRITS T SERIES LIGHTOLIER SW SERIES MOUNTING HEIGHTS HEIGHT OF OUTLETS MEASURED TO CENTER OF BOX, UNLESS OTHERWISE INDICATED COUNTER HEIGHT ( *) CASEWORK AND OTHER OUTLETS WIRING DEVICES SWITCHES AND DIMMERS RECEPTACLES THERMOSTATS SIGNAL VOICE (TELEPHONE) DATA (COMPUTER) WALL PHONE FIRE ALARM MANUAL STATIONS SIGNALING DEVICES REMOTE ALARM LIGHTS +3 INCHES ABOVE SPLASH AS DIRECTED 48 INCHES 18 INCHES 54 INCHES 18 INCHES 18 INCHES 48 INCHES 48 INCHES TO TOP 80 INCHES TO BOTTOM 80 INCHES TO BOTTOM REMODEL SYMBOL LEGEND SYMBOL EXAMPLE REMARKS HEAVY LINE WEIGHT DETAIL SYMBOL: NEW WORK STANDARD LINE WEIGHT A- IDENTIFYING NUMBER EXISTING TO REMAIN UNLESS NOTED B -SHEET WHERE DETAIL TAKEN OTHERWISE. (SEE REMODEL NOTES) �A BUBBLE NOTE TAG SYMBOL: N CROSS HATCH LINE WORK A— IDENTIFYING NUMBER ELECTRICAL DEMOLITION REFERENCE SYMBOL LEGEND SYMBOL DESCRIP11ON REMARKS o Q DETAIL SYMBOL: AS INDICATED ON DRAWINGS B `-� A- IDENTIFYING NUMBER I- B -SHEET WHERE DETAIL TAKEN �A BUBBLE NOTE TAG SYMBOL: N A— IDENTIFYING NUMBER LIGHTING CONTROL NOTES: 1. THE FOLLOWING NOTES REFERENCE APPLICABLE SECTIONS OF THE WASHINGTON STATE ENERGY CODE. 2. PROVIDE EACH ROOM WITH LOCAL LIGHTING CONTROL AT THE ENTRY /EXIT DOOR UNLESS OTHERWISE NOTED AS AN EXCEPTION (SECTION 1513.1) 3. THE MAXIMUM LIGHTING LOAD CONTROLLED BY A SINGLE SWITCH OR AUTOMATIC CONTROL SHALL NOT EXCEED 16 AMPS. (SECTION 1513.2) 4. PROVIDE SEPARATE CONTROL OF DAYLIGHTED ZONES INDEPENDENT OF GENERAL AREA LIGHTING. — INDICATES BOUNDARY OF DAYLIGHTED ZONES. (SECTION 1513.3) 5. PROVIDE OCCUPANCY SENSORS IN SCHOOL CLASSROOMS TO AUTOMATICALLY TURN OFF LIGHTS WHEN ROOM IS UNOCCUPIED. SET TIME DELAY FOR 10 MINUTES (SECTION 1513.6) 6. COMMISSIONING REQUIREMENTS FOR DAYLIGHT AND OCCUPANT SENSING AUTOMATIC CONTROLS, OCCUPANCY SENSORS, AUTOMATIC 11ME SWITCHES: THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. PREPARE A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS AND SUBMIT TO THE OWNER. (SECTION 1513.7) GENERAL ELECTRICAL NOTES: 1. SEE ARCHITECTURAL PLANS FOR LOCATION OF FIRE RATED CONSTRUCTION. 2. BRANCH CIRCUIT NOTES: A. ONLY BRANCH CIRCUIT HOMERUNS INDICATE CONDUCTOR COUNT IF MORE THAN TWO WIRE CIRCUIT PLUS GROUND. CONTINUE WIRE COUNT TO OUTLETS AS REQUIRED TO PROVIDE INDICATED PHASE, NEUTRAL, ISOLATED GROUND AND EQUIPMENT GROUND CONDUCTORS PER CODE BASED ON CIRCUIT DESIGNATIONS INDICATED. B. FOR SWITCHED OUTLETS, PROVIDE ADDITIONAL CONDUCTOR COUNT REQUIRED FOR SWITCH LEGS TO ACCOMMODATE SWITCH CONTROL INDICATED. MAINTAIN UNSWITCHED LEG IN LIGHTING BRANCH CIRCUITS TO EXIT, EMERGENCY, AND NIGHT LIGHTING SHOWN. C. NEUTRAL CONDUCTOR SIZE FOR MULTI -WIRE BRANCH CIRCUITS SERVING COMPUTER PURPOSE OUTLETS SHALL BE #10 AWG MINIMUM. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR COMPUTER PURPOSE CIRCUITS WHERE COMPUTER PURPOSE AND GENERAL PURPOSE CIRCUITS SHARE THE SAME CONDUIT. 3• MINIMUM CONDUIT SIZE FOR HOMERUNS SHALL BE 3/4 INCH. 4. WHERE ROOM OCCUPANCY SENSORS ARE INDICATED, PROVIDE QUANTITY AND LOCATION OF DEVICES PER MANUFACTURER'S RECOMMENDATION FOR COMPLETE ROOM COVERAGE AND TO MINIMIZE FALSE ACTIVATION THRU OPEN DOORS. 5. REFER TO ARCHITECTURAL PLANS FOR LIGHT FIXTURE LOCATIONS AND FOR MOUNTING HEIGHT OF SUSPENDED AND WALL MOUNTED LIGHT FIXTURES. REFER TO REFLECTED CEILING PLANS, INTERIOR ELEVATIONS, EXTERIOR ELEVATIONS, ROOM SECTIONS. AND DETAILS SHOWN ON ARCHITECTURAL CONTRACT DOCUMENTS PRIOR TO ROUGH -IN. REPORT CONFLICTS TO ARCHITECT /ENGINEER FOR RESOLUTION. 6. REFER TO ARCHITECTURAL ELEVATIONS FOR LOCATION AND MOUNTING HEIGHT OF WIRING DEVICES. REPORT CONFLICTS TO ARCHITECT /ENGINEER FOR RESOLUTION. 7. VERIFY EXACT LOCATION OF OUTLETS LOCATED IN KNEE SPACES AND CASEWORK. OBTAIN ARCHITECT APPROVAL PRIOR TO ROUGH -IN. 8. VERIFY BACK BOX REQUIREMENTS OF EQUIPMENT FURNISHED UNDER OTHER THAN DIVISION 16 SECTIONS AND EQUIPMENT FURNISHED BY OWNER. 9. SEE MECHANICAL PLANS FOR QUANTITY AND LOCATION OF SMOKE DAMPERS. PROVIDE 120 VOLT CONNECTION TO EACH DAMPER. REMODEL ELECTRICAL NOTES: 1, REPLACE EXISTING WIRING DEVICES AND FACEPLATES WITH NEW WHERE INDICATED AS HEAVY LINE WEIGHT. 2, FIRE ALARM SYSTEM IS EXISTING. SYMBOLS SHOWN IN HEAVY LINE WEIGHT INDICATE NEW DEVICE AND TRIM. EXCEPT, REMOVE AND SALVAGE EXISTING DEVICE FOR RE -USE WHERE INDICATED. REPLACE WIRING WITH NEW. EXISTING RACEWAY SYSTEM MAY BE REUSED. 3, EXISTING BRANCH CIRCUIT WIRING MAY INTERFERE WITH NEW HVAC DUCTS AFTER ALLOWANCE FOR OFF -SET. INCLUDE LABOR AND MATERIALS FOR RELOCATING 150 FEET OF CONDUIT, 500 FEET OF CONDUCTORS, AND 5 OUTLET BOXES, BASED ON MAXIMUM 3/4" CONDUIT AND #10 THWN CONDUCTORS. vJ v o r ao Ntv0 •- M I X10 ti N L N � 4' .0 I v y p u m MO„ < U " 0 a� o3 _ L I O � Z ox �••� c o o N aV u N i0- x J ZD 0 r l U W X LL r) W J Q U W J W w CN W 4t WO U0 .. Z U 0 <z I= U�< =) Q C hJ Q Ciew0 Q O J C W W :�E >- >- i MPUMM 4/27/0+ PROJECT 21049 DRAWN: DATE 3/25/03 SHEET EOO I OF: Z o Q E U I- o. ral� N C6 0 N N � o u o � CD o V N oo' J Q�Q W V ' v, co o. 4 ) 0 m 3 .c O M E V U o .O Q vJ v o r ao Ntv0 •- M I X10 ti N L N � 4' .0 I v y p u m MO„ < U " 0 a� o3 _ L I O � Z ox �••� c o o N aV u N i0- x J ZD 0 r l U W X LL r) W J Q U W J W w CN W 4t WO U0 .. Z U 0 <z I= U�< =) Q C hJ Q Ciew0 Q O J C W W :�E >- >- i MPUMM 4/27/0+ PROJECT 21049 DRAWN: DATE 3/25/03 SHEET EOO I OF: rAfAT;wl , C- t - BUBBLE NOTES: SALVAGE FOR RELOCATION, SEE E2.1 GENERAL -NOTE: 1. UNLESS OTHERWISE NOTED, SALVAGE ALL DEMOLISHED LIGHT FIXTURES EITHER FOR RE-USE OR TO DELIVER TO OWNER. igollAN XNA NORTH ELECTRICAL DEMO LIGHTING PLAN 1/811 = 1 1 - 0 11 7 owl O ry 04 IL BUBBLE NOTES: SALVAGE FOR RELOCATION, SEE E2.1 GENERAL -NOTE: 1. UNLESS OTHERWISE NOTED, SALVAGE ALL DEMOLISHED LIGHT FIXTURES EITHER FOR RE-USE OR TO DELIVER TO OWNER. igollAN XNA NORTH ELECTRICAL DEMO LIGHTING PLAN 1/811 = 1 1 - 0 11 w VJ O ry 04 IL ui u 0 0 to (o lro�: U (.4 C'4 0 41 M O .3 'CID V) C=l 4; d) E U Z L 00; W 41 z0~ 41 It 0 ti > 00 < be 11) 00 � U (7) -c 0 < CC r-4 Z ml Z E 0 Oo 0 • u tq 75 o � � 0 LLJ UR4 u o. MUM 4/VAfl PROJECT 21049 z DRAWN' DATE 3/25/03 0 V (L 4- r= 0 u 0 4-J Q 0 A c: o �2— 0 t1i w VJ O ry 04 IL ui u 0 0 to (o U (.4 C'4 0 41 M .3 'CID V) 4; d) E U Z L 00; W 41 z0~ 41 It 0 ti It c 00 < be 11) 00 � U (7) -c 0 < CC r-4 Z ml Z E 0 Oo 0 u tq 75 o � � SHEET E1.1 OF: ry 04 IL ui 7 w0 (.)o U 0 00; z0~ o 00 < Z � U Z:) < r-4 Z U-J 0 u c� o � � 0 LLJ UR4 o. MUM 4/VAfl PROJECT 21049 DRAWN' DATE 3/25/03 SHEET E1.1 OF: EXIST J SERVICE POLE ca I r EXIST TELEPHONE PEDESTAL EXIST METER EXIST AERIAL SECONDARY SERVICE �— M l wWH i L L2 WH � =10� 2 2 YI P CT 3 TV HEAD END 2,� 2,27 __� ELEC. � MEN MTV-+ - i ya 006 009 SERVER WOKEN F EF - -- - ON ROOF JAN JME? H. I SEE PARTIAL PLAN ; ; ; - -- _., F ON THIS SHEET. 3 WAREHOUSE L2 -15,19 L2 -22 L 5 pfl 15 19 L2 -17 15 13 (TYP) 6 L2 -26 -28 +48" 13 L2 -4 6,7 4 w CLASSROOM 013 +48" 3 13j Lr l� L2 -8,10 -13,15 8 L2 -5 2 -23 U L2 -3 MEETING i 017 5 WP 5 VA ON ROOF 5 ON OOF 5 VA 3 L2 -11 _ RECEIVING STORAGE 015 +48" 10 CLASSROOM 10 016 +48" 12 10 Vyp 12 L2 -12,14 VA ON ROOF 14 i 11 0 1 16 G BUBBLE NOTES: !� `1 ) �} ) O1 DEMO O2 EXIST GEAR, SEE E5.1 Q3 SALVAGE FOR RELOCATION, SEE E3.1 r i 4 - �. _ - - -- J -- - - -- - — - -I - - - -- -- G ) n_ n, s_- i J 1 ELECTRICAL DEMO POWER AND SIGNAL 1/8 "= 1 ' -0" Est 1449 NAL E Z PROJECT o E Q U DRAWN: DATE 3/25/03 a L0 N N U v OnOD NN in O p —� J 4D 0 O r 16 E U O � v Z � C> N l o a` O n �o F�1 0 q N� aL 03 1 � N a Z o� x m O O U N u N H = J Q z Z O V) Q, Q N Z W 4t OD J w w0 3: UO O IL .. Z U 0 0 ro V. 7 N O n (n L W Z ~ ~ w Est 1449 NAL E 4/'7/04 PROJECT 21049 DRAWN: DATE 3/25/03 L0 v OnOD NN in O p J 4D 0 16 E � v Z b N l o M n �o F�1 0 q N� aL 03 1 a Z o� x m O O U u N H = J Q Z V) Q N Z W 4t Z J w w0 3: UO O IL .. Z U 0 0 0 }- Z ~ ~ w Q Z o � U� Q N U Zw0 U w W 0 ``J -� w `Wr Est 1449 SHEET El 02 NAL E 4/'7/04 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET El 02 ""1 0 C r - WAREHOUSE i I I BUBBLE NOTES: 01 REINSTALL SALVAGE FIXTURE 02 EXISTING BRANCH CKT. TO REMAIN SEE E1.1 FOR MORE INFORMATION i 4 U BUBBLE NOTES: 01 REINSTALL SALVAGE FIXTURE 02 EXISTING BRANCH CKT. TO REMAIN SEE E1.1 FOR MORE INFORMATION �i NORTH ELECTRICAL LIGHTING 1 /8'I= I I - OII OFFICE BUILDING NO WORK HERE ZE i 4 U Cri �i NORTH ELECTRICAL LIGHTING 1 /8'I= I I - OII OFFICE BUILDING NO WORK HERE ZE 4 U Cri a E v N h � N C U �uu 0. O Lu � 3 ONO Nr� � Lu (� f� w � to E •O L7 u b J V) a v r ci o C z ro d hQ �+ 17 00 y N �. < 3 I a , ? Ln Z dr om CID [ O o V .. :3 u N !0- MMRIM 4/R7/04 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E2.1 U rrVJ vJ � v 0 0 >I" OD 0. U � � 3 ONO Nr� � E (� w � to MMRIM 4/R7/04 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E2.1 rrVJ vJ 0 ONO Nr� I N :$ Z b J V) J v r ci o C hQ �+ 17 00 y N �. < 3 I a , ? Ln Z dr om CID [ O o V .. :3 u N !0- CV W 41-- I- V) Z --I w0 Uo C.� .. Z U z 0 0 `) 0 0Qz Q N U -c� w0 ULLJ�CC W w 0 --� W J W < WIIIIIIIIIIIIIIII MMRIM 4/R7/04 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E2.1 D wma-3111mwo E 33 RECEPTION BUBBLE NOTES: INTERCEPT AND EXTEND EXIST CKT. RECONNECT EXISTING SMOKE DAMPER INSTALL DEVICES IN CUT—OUT PROVISION IN BASE OF COLUMN. L2— 14 31 401 KI I UMN 012 MAI 2 L2-29,31.33 4> _4 G c 41 IRARY 021 1 CLASSROOM CLASSROOM �i Oa ELECTRICAL POWER -& SIGNAL 1/8 "= I ' -0" Q� CN uj * < C/) ZI w0 c/) U0 06 r ..Z u Oe 0 0 v) w Z 0 0<2 I N < U _Z Lu 0 w ce U w U w 1 0 w NAL LL, Li F=nF= 4/R7/041 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E301 OF: E 0 0 U0 0 rn 00 10 (o 15D 0 4r OD M L E > bt .0 4J �o It be V) 00 di 0 L 0 Z r� Em 0 O 0 , v 0 :) x 0 OD u < c 0 0 C) Q� CN uj * < C/) ZI w0 c/) U0 06 r ..Z u Oe 0 0 v) w Z 0 0<2 I N < U _Z Lu 0 w ce U w U w 1 0 w NAL LL, Li F=nF= 4/R7/041 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E301 OF: 0 U0 0 rn 00 10 (o .2 0 4r OD M L E Z bt .0 4J �o It be V) 00 di L 0 Z r� Em 0 O 0 , v 0 :) x Q� CN uj * < C/) ZI w0 c/) U0 06 r ..Z u Oe 0 0 v) w Z 0 0<2 I N < U _Z Lu 0 w ce U w U w 1 0 w NAL LL, Li F=nF= 4/R7/041 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E301 OF: PANEL SCHEDULE NOTES: 1. HEAVY LINE WORK INDICATES NEW WORK IN EXISTING PANELS. PROVIDE NEW BREAKERS AND UP DATED TYPED INDEX CARDS FOR ALL PANEL BOARDS. PNL -L (E) 120/240V 10 (E)CT W /BUSSING 800A, 240V 30 PNL -L2 (E) j 120/240V 10 PNL -P (E) 240V 30 1 EXIT i i 5 GUTTER 4 - 7 EXIST ELECTRICAL RISER DIAGRAM SCALE: NTS TO UTILITY POLE MOUNT SERVICE XI O EXIST SERVICE DR( 1000A/700A LOAD SUMMARY (REVISED) DESCRIPTION I KVA I DEMAND I NEC REF( KVA I 3 PHASE LOADS PANEL P SUBTOTAL SINGLE PHASE PANEL SCHEDULE SCHEDULE 183.4 1 PHASE LOADS PANEL L ID: ID: L REVISED Enclosure: Voltage: 120/240, 3W Amps Assembly Rating: 200 Amps Assembly AIC: ❑Flush Section: 1 OF 1 ❑Flush 3 #2/0, 1#1/0 GND. []Main Lugs ❑10K ❑Main Lugs Location: ❑X Surface ❑10K ❑X Isolated Gnd Location: ti OSurface Olsolated Gnd ❑X Main Breaker ❑X Main Breaker ❑NEMA 3R E] 22K ❑TVSS ❑NEMA 3R ❑NEMA 3R Lugs ❑ TVSS ❑X Feed Thru Lugs X❑ Feed Thru Lugs 12/3R ❑ 42K ❑200% Neutral ❑NEMA 12/3R ❑NEMA 12/3R ❑200% Neutral CODE DESCRIPTION []Double Lugs BKR DESCRIPTION CKT CODE DESCRIPTION BKR VA BKR DESCRIPTION CKT PHASE CKT BKR u VA DESCRIPTION HVAC /1 1 CODE L LTG 1 975 20/1 2 1 A 2 20/1 540 970 LTG 3 C L L LTG 500 400 20/1 C 3 C 4 20/1 20/1 960 LTG A 6 L L LTG REC -COMP 1200 20/1 R 5 A 6 20/1 970 LTG 8 20/1 L L LTG 7 1600 20/1 REC -CONY 7 C 8 20/1 9 1200 LTG 20/1 L L LTG C 520 20/1 10 9 A 10 20/1 C 402 LTG - EXTERIOR 500 L L LTG R 670 20/1 720 11 C 12 A 14 20/1 SPACE 500 REC -COMP 200 C SPACE REC -CONY W 1080 20/1 13 A 14 20/1 20/1 260 LTG - UNFINISHED AREA o�g L R SPACE 15 360 20/1 16 15 C 16 20/1 O 250 SPACE DISPOSER C R M EF /1 900 480 20/1 19 17 A 18 500 REC -COMP SPACE C R REC -CONY LM EF /2, CP /1, WH /1 (GAS) 1060 20/1 A 19 C 20 500 FIRE ALARM CONTROL PANEL 0 SPACE REC -COMP 250 M EF /3 23 696 20/1 20/1 21 A 22 M M SPACE SPACE 860 20/1 L LTG A 465 20/1 24 23 C 24 M C REC -TTB, MDF, MTC, TV SPACE 500 20/1 L LTG 28 780 20/1 1500 25 A 26 C REC -COMP SPACE 20/1 29 L LTG 20/1 1170 20/1 REC -SMALL APPLIANCE 27 C 28 REC -COMP 750 SPACE SPACE 31 C L LTG 29 1252 20/1 30 29 A 30 900 20/1 SPACE 33 A 34 L LTG 31 1030 20/1 32 31 C 32 750 20/1 M SPACE C 36 L LTG SPACE 1200 20/1 C 33 A 34 20/1 37 SPACE 38 SPARE 35 20/1 REC -CONV 35 C 36 39 C SPACE SPACE SPACE SPARE 37 R 20/1 38 37 A 38 41 A 42 SPACE SPACE SPACE SPACE 39 B 40 39 C 40 I C PHASE SPACE SPACE 12.8 1 SPACE 41 1 1 42 41 A 42 SPACE TOTAL KVA AMPS Code Description KVA C A KVA I C PHASE CONNECTED 25.8 107.3 9.7 L 1 8.6 0.0 KVA CONNECTED 0.0 KVA CONNECTED LOAD SUMMARY 107.2 LOAD SUMMARY R Receptacles 10.0 X TOTAL A VA AMPS AMPS Code Description KVA KVA KVA Receptacles over 10KVA 0.8 X 50% CONNECTED 18.3 76.1 L Lighting 16.0 X 125% 20.0 8.5 X 100% 8.5 CALCULATED 22.5 93.9 SPARE R Receptacles 0.0 X 100% 0.0 X 100% 3.0 R C Receptacles over 1OKVA 0.0 Computers 0.0 R Receptacles over 1OKVA 0.0 X 50% 0.0 125% 1.9 REMARKS: C Computers 0.0 X 100% 0.0 31.9 SPARE CAPACITY: 53.1% N M Motors 1.2 X 100% 1.2 0 Other LM Largest Motor 1.1 X 125% 1.3 REMARKS: Remainder 0.0 K Kitchen 0.0 X 100% 0.0 Remainder 3.8 N Noncoincident 0.0 X 0% 0.0 0 Other 0.0 X 100% 0.0 Remainder 0.0 X 100% 0.0 PANEL SCHEDULE NOTES: 1. HEAVY LINE WORK INDICATES NEW WORK IN EXISTING PANELS. PROVIDE NEW BREAKERS AND UP DATED TYPED INDEX CARDS FOR ALL PANEL BOARDS. PNL -L (E) 120/240V 10 (E)CT W /BUSSING 800A, 240V 30 PNL -L2 (E) j 120/240V 10 PNL -P (E) 240V 30 1 EXIT i i 5 GUTTER 4 - 7 EXIST ELECTRICAL RISER DIAGRAM SCALE: NTS TO UTILITY POLE MOUNT SERVICE XI O EXIST SERVICE DR( 1000A/700A LOAD SUMMARY (REVISED) DESCRIPTION I KVA I DEMAND I NEC REF( KVA I 3 PHASE LOADS PANEL P SUBTOTAL SINGLE PHASE PANEL SCHEDULE SCHEDULE 183.4 1 PHASE LOADS PANEL L ID: L2 REVISED Enclosure: Voltage: 120/240, 3W Voltage: 120/240, Rating: 200 Amps Assembly AIC: Amps Section: 1 OF 1 ❑Flush Section: 1 OF 1 []Flush 3 #2/0, 1#1/0 GND. []Main Lugs ❑10K Location: ❑X Surface ❑X Isolated Gnd X❑Surface ti X❑Main Breaker ❑22K ❑X Main Breaker ❑NEMA 3R ❑TVSS ❑NEMA 3R ❑Feed Thru Lugs X❑42K ❑X Feed Thru Lugs ❑NEMA 12/3R ❑200% Neutral ❑NEMA 12/3R []Double Lugs ❑Double CODE DESCRIPTION VA BKR DESCRIPTION CKT PHASE CKT BKR CKT VA DESCRIPTION BKR CODE R REC -CONY u 900 20/1 HVAC /1 1 A 2 20/1 1 750 REC -COMP 2 C R REC -CONY 540 20/1 M 3 C 4 20/1 500 REC -COMP B C R REC -CONY F 720 20/1 M 5 A 6 20/1 500 REC -COMP C R REC -CONY 2149 900 20/1 7 C 8 20/1 2870 500 REC -COMP 7 C, R REC -CONY 80/3 540 20/1 0 9 A 10 20/1 500 REC -COMP C R REC -CONV 10 900 20/1 11 C 12 20/1 500 REC -COMP C R REC -CONY -ROOF C 720 20/1 8514 13 A 14 20/1 0 500 REC -COMP 200 C R REC -CONY W 1080 20/1 15 C 16 20/1 500 REC -COMP o�g C R REC -CONY 15 360 20/1 16 17 A 18 20/1 O 250 REC -COMP DISPOSER C R REC -CONY 900 20/1 C 19 C 20 20/1 500 REC -COMP M C R REC -CONY 20/1 540 20/1 21 A 22 20/1 500 FIRE ALARM CONTROL PANEL 0 C REC -COMP 250 20/1 23 C 24 20/1 800 FIRE /SMOKE DAMPERS M M SEWER PUMP (1 /3HP) SPACE 860 20/1 25 A 26 20/1 24 650 REFRIGERATOR EWH /1 M C REC -TTB, MDF, MTC, TV 500 20/1 27 C 28 20/1 A 1500 FREEZER 1875 LM C REC -COMP 750 20/1 29 A 30 20/1 1500 REC -SMALL APPLIANCE 0 C REC -COMP 750 20/1 SPACE 31 C 32 20/1 29 650 REC- REFRIGERATOR 30 M R REC -CONV 900 20/1 33 A 34 31 SPACE A 32 C REC -COMP 750 20/1 M 35 C 36 SPACE B C REC -COMP 2149 500 20/1 37 A 38 SPACE 35 R REC -CONV 900 20/1 39 C 40 SPACE SPACE 37 R REC -CONV 38 900 20/1 SPACE 41 A 42 SPACE SPACE 39 B 40 A I C PHASE SPACE 12.8 1 1 12.9 41 KVA CONNECTED 42 LOAD SUMMARY TOTAL KVA AMPS Code Description KVA C PHASE KVA CONNECTED 25.8 107.3 L Lighting 0.0 X 125% 0.0 KVA CONNECTED CALCULATED 25.7 107.2 LOAD SUMMARY R Receptacles 10.0 X 100% 10.0 KVA AMPS Code Description KVA R Receptacles over 10KVA 0.8 X 50% 0.4 67.5 162.5 L Lighting 0.0 X C Computers 8.5 X 100% 8.5 73.9 177.8 SPARE CAPACITY: 46.4% 0.0 X M Motors 3.0 X 100% 3.0 R C Receptacles over 1OKVA 0.0 Computers 0.0 X X 50% 100% LM Largest Motor 1.5 X 125% 1.9 REMARKS: K Kitchen 0.0 X 100% 0.0 31.9 REMARKS: N Noncoincident 0.0 X 0% 0.0 0.0 0 Other 2.0 X 100% 2.0 0.0 Remainder 0.0 X 100% 0.0 5.5 PANEL SCHEDULE NOTES: 1. HEAVY LINE WORK INDICATES NEW WORK IN EXISTING PANELS. PROVIDE NEW BREAKERS AND UP DATED TYPED INDEX CARDS FOR ALL PANEL BOARDS. PNL -L (E) 120/240V 10 (E)CT W /BUSSING 800A, 240V 30 PNL -L2 (E) j 120/240V 10 PNL -P (E) 240V 30 1 EXIT i i 5 GUTTER 4 - 7 EXIST ELECTRICAL RISER DIAGRAM SCALE: NTS TO UTILITY POLE MOUNT SERVICE XI O EXIST SERVICE DR( 1000A/700A LOAD SUMMARY (REVISED) DESCRIPTION I KVA I DEMAND I NEC REF( KVA I 3 PHASE LOADS PANEL P SUBTOTAL THREE PHASE PANEL SCHEDULE 183.4 1 PHASE LOADS PANEL L PANEL ID: P REVISED Enclosure: Voltage: 120/240, 4W PHASE Rating: 400 Amps Assembly AIC: C Section: 1 OF 1 []Flush 3 #2/0, 1#1/0 GND. []Main Lugs ❑10K Location: X❑Surface ti ❑Isolated Gnd ❑X Main Breaker ❑22K ❑NEMA 3R ❑TVSS ❑X Feed Thru Lugs ❑X 42K �e ❑NEMA 12/3R ❑200% Neutral ❑Double Lugs CODE DESCRIPTION 0 VA BKR CKT PHASE CKT BKR VA DESCRIPTION u CODE M HVAC /1 2870 30/3 1 A 2 20/3 2149 HVAC /3 CN M M 2870 3 B 4 V) 2149 F o b M M 2870 WO 5 C 6 2149 0 S M M HVAC /2 2870 30/3 7 Z A 8 80/3 8514 HVAC /4 0 � LM M 2870 � 9 B 10 8514 0<z LM M 0 2870 U 11 C 12 I-- Q 8514 U_ LM 0 GAS RANGE 200 20/1 13 W A 14 SPACE 0 DISHWASHER o�g 1500 20/1 15 B 16 SPACE O W M DISPOSER 1 /2HP 1180 20/1 17 C 18 20/2 1875 EWH /2 0 M DISHWASHER 1500 20/1 19 A 20 1875 SPACE 21 B 22 SPACE SPACE 23 C 24 20/2 1875 EWH /1 0 SPACE 25 A 26 1875 SPACE 27 B 28 SPACE SPACE 29 C 30 20/3 2149 HVAC /5 M SPACE 31 A 32 2149 M SPACE 33 B 34 2149 M SPACE 35 C 36 SPACE SPACE 37 A 38 SPACE SPACE 39 B 40 SPACE SPACE 41 C 42 ISPACE A B C PHASE 24.0 20.1 23.5 KVA CONNECTED LOAD SUMMARY TOTAL LOAD KVA AMPS Code Description KVA KVA CONNECTED 67.5 162.5 L Lighting 0.0 X 125% 0.0 CALCULATED 73.9 177.8 R Receptacles 0.0 X 100% 0.0 R C Receptacles over 1OKVA 0.0 Computers 0.0 X X 50% 100% 0.0 0.0 SPARE CAPACITY: 55.5% M Motors 32.8 X 100% 32.8 LM Largest Motor 25.5 X 125% 31.9 REMARKS: K Kitchen 0.0 X 100% 0.0 N Noncoincident 0.0 X 0% 0.0 0 Other 5.5 X 100% 5.5 Remainder 3.8 X 100% 3.8 PANEL SCHEDULE NOTES: 1. HEAVY LINE WORK INDICATES NEW WORK IN EXISTING PANELS. PROVIDE NEW BREAKERS AND UP DATED TYPED INDEX CARDS FOR ALL PANEL BOARDS. PNL -L (E) 120/240V 10 (E)CT W /BUSSING 800A, 240V 30 PNL -L2 (E) j 120/240V 10 PNL -P (E) 240V 30 1 EXIT i i 5 GUTTER 4 - 7 EXIST ELECTRICAL RISER DIAGRAM SCALE: NTS TO UTILITY POLE MOUNT SERVICE XI O EXIST SERVICE DR( 1000A/700A LOAD SUMMARY (REVISED) DESCRIPTION I KVA I DEMAND I NEC REF( KVA I 3 PHASE LOADS PANEL P SUBTOTAL 107.3 44.0 183.4 1 PHASE LOADS PANEL L PANEL L2 SUBTOTAL GUTTER. TOTALS EXISTING PHASE A PHASE B PHASE C NOTES: 1. SEE PANFI_ SCHEDULE 67.5 162.3 NOTE 1 73.9 177.7 NOTE 1 67.5 162.3 73.9 177.7 18.3 76.1 25.8 107.3 44.0 183.4 SERVICE POINT UTILITY SECONDARY (E) 36,084 A!r 345.8 1 62.3 44 5,,3 NOTE 1 NOTE 1 22.5 25.7 48.3 EXIST ELECTRICAL ONE -LINE DIAGRAM SCALE: NTS O1 BUBBLE NOTES: METER EXIST UTILITY O2 EXIST SERVICE SECONDARY. O EXISTING CT WITH 800A BUSSING ® EXISTING GUTTER. �5 EXISTING 4 "C, 4#600KCM AND 1#11/0 GND. ® EXISTING 4 "C, 6 #2/0, 11#11/0 GND AND 1#1/0 ISOL. GND. (D EXISTING 2 "C, 3 #2/0, 1#1/0 GND. 93.9 107.2 201.1 376.8 1777,7 7'8 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E5.1 w E 0 Q .n A C A c%) o u � ° o v ti r. �e n U7 0 z z dT 0 o o� u .+ Nh�-= CN F- V) F o b J WO o o U 0 S PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E5.1 w w v ti r. �e n 0 z dT 0 o o� u .+ Nh�-= CN F- V) J WO U 0 Uj Z U Z .. 0 0 � � W Z I- 0<z 0 U J I-- Q U_ Np� W 0 U o�g -� O W w PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E5.1 w MECHANICAL EQUIPMENT MANUAL �TA)iONS 2 MANUAL_ STATIONS 3 SMOi';E UETE"'TORS 4 SMOKE DETE`t,TORS 5 CONNECTION SCHEDULE SPRINKLER AMPEP (SUPERVISORY) 7 SPRINKLER LOW AID; (SUPERVIS ',PY) L DUCT SMOKE DETE :TC; —. r SPARE 10 SP ARE MAXIMUM RATINGS SPARE FEEDER DISCONNECT CONTROL SYMBOL DESCRIPTION LOCATION SIZE FLA MCA MOP VOLT /PH 1/2 "C, x!12 EACH PHASE, NEUTRAL, PLUS GROUND UNLESS OTHERWISE INDICATED BELOW vwi Q CL v F REMARKS I p �%_ u.j P w to N VA 5 HEAT PUMP ROOF -TOP 15.5 20.0 240/3 I M EQUIPMENT CONNECTION SCHEDULE_ NOTES: 1. OUTLETS, DISCONNECTS, CONTROLLERS, AND EQUIPMENT CONNECTIONS FOR ROOF TOP AND OTHER OUTDOOR EQUIPMENT SHALL BE WEATHER PROOF. 2. LOCATION OF OUTLETS, DISCONNECTS, CONTROL DEVICES, AND EQUIPMENT CONNECTIONS ARE DIAGRAMMATIC AND TO BE LOCATED IN FIELD BY THE CONTRACTOR AS APPROVED BY THE ENGINEER. UNLESS OTHERWISE INDICATED ON PLANS, INSTALL SCHEDULED DISCONNECTS AND CONTROL DEVICES INSIGHT OF EQUIPMENT. ARRANGE WIRING AND EQUIPMENT TO AVOID INTERFERENCE WITH OTHER WORK AND TO MAXIMIZE ACCESSIBILITY FOR MAINTENANCE AND REPAIRS. 3. COORDINATE WITH THE OTHER INSTALLING CONTRACTORS TO ENSURE NEC REQUIRED ACCESS TO DISCONNECTS IS PROVIDED FOR EACH PIECE OF EQUIPMENT. 4. PROVIDE SMOKE DUCT DETECTORS IN HEATING AND COOLING SYSTEMS PER UNIFORM MECHANICAL CODE. SEE DIVISION 15 EQUIPMENT SCHEDULES FOR ADDITIONAL UNITS RATED OVER 2000 CFM AND PROVIDE DUCT DETECTOR AS REQUIRED.. 5. WIRING BETWEEN EQUIPMENT DISCONNECT AND POINT OF CONNECTION SHALL COMPLY WITH NEC BASED ON EQUIPMENT NAMEPLATE RATING EXCEPT MINIMUM BRANCH CIRCUIT RATING SHALL BE 20 AMPERES. 6. SIZE OF DISCONNECT SWITCH AND MOTOR STARTER SHALL BE SIZED TO COMPLY WITH NEC REQUIREMENTS. 7. SCHEDULE LEGEND: • = FURNISH AND INSTALL NEW UNDER DIVISION 16 O = INSTALL UNDER DIVISION 16; FURNISHED WITH EQUIPMENT OR BY OTHERS X = FURNISH AND INSTALL BY OTHERS (NOT DIVISION 16) * = EXISTING, RELOCATED EQUIPMENT. CONTROL WIRING /-ULTRASONIC CEILING SENSOR. LOCATE PER MANUFAC7JRER'`_ I 0rnq MAXIMUM COVERAGE WITHIN ROOM RECOMMENDA°R(: NS Ar'^ TC MINIMIZE FALSE ACTIVATION THPP i OPEN DOORS AS PECOMMENDED 13) VIAN' tFACTURER. SENSORS SHALL TO ADDITIONAL AE'" VE 12 FEES'. i RELAY(S) AS REQUIRED! ACDDI I :f" AL SENSORS AS REQUIREF FOR ROOM COVE:'4 ?.GE i I POWER RELAY -� ATC INTERFACE BY DIV 15 LINE 120/277VAC NEUT NL WA —_L SWITCH C, )NTROLS i,T ENTI-Y DOC I :" 3 PER P,,AN WIRING DIAGRAM ADDITIONAL RELAY(S) AS REQUIRED I-- — ROOM LIGHTING OUTLET WITH SWITCH LEADS 120/277V POWER RELAY — --� ADDITIONAL SENSOR SENSORS AS REQUIRED ONE -LINE DIAGRAM ROOM OCCUPANCY SENSOR SCALE: NTS 1 MANUAL �TA)iONS 2 MANUAL_ STATIONS 3 SMOi';E UETE"'TORS 4 SMOKE DETE`t,TORS 5 SPRINKLER f= '...OW E SPRINKLER AMPEP (SUPERVISORY) 7 SPRINKLER LOW AID; (SUPERVIS ',PY) L DUCT SMOKE DETE :TC; —. r SPARE 10 SP ARE 11 SPARE 12 SPARE ATC FAN SHUT DOWN 120V VERIFY WITH SPRINKLER PIV CONTRACTOR F - - --1 L - - -J DDCV VAULT YROViDE NEW DEVICES ;,T "r 7su �n 1 v n , �> I. ZONES 5, 6, 7 YIrl r ! UPGRADE EXISTING , AS REQUIRED DIGITAL `!MTR TELEPHONE LINE #1 TELEPHONE LINE #2 PROVIDE PROGRAMMING TO EXIST PANEL AS REQUIRED EXIST FIRE ALARM RISER DIAGRAM SCALE: NTS Cle o N U 41 � O Q` � U C/'`j O o O -� v cn e U � � J 4 � I 0 '^> N on P �% r < U H 3 ^ c G O (J V O i+, E �i O W r0- lJ Q 4 r ".•Ili:;: "91� ^. "�= :�v�':�ii$ i? v G ; bc N O ec M 0 < b Li N NQ�j N� o�" w ZC;m a[ 0 0 N 0 v N F = Q LIU Q U J w 1, F, ;w w 04 ui Z —� w0 U0 .. Z U I— O >- Z H I- 0 < 1= U N � Zw�O w U Q L 11. 4/97/04 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E7.1 OF: z U E CJ� 4 4 a Uo E 4 r ".•Ili:;: "91� ^. "�= :�v�':�ii$ i? v G ; bc N O ec M 0 < b Li N NQ�j N� o�" w ZC;m a[ 0 0 N 0 v N F = Q LIU Q U J w 1, F, ;w w 04 ui Z —� w0 U0 .. Z U I— O >- Z H I- 0 < 1= U N � Zw�O w U Q L 11. 4/97/04 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E7.1 OF: Q LIU Q U J w 1, F, ;w w 04 ui Z —� w0 U0 .. Z U I— O >- Z H I- 0 < 1= U N � Zw�O w U Q L 11. 4/97/04 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E7.1 OF: L 11. 4/97/04 PROJECT 21049 DRAWN: DATE 3/25/03 SHEET E7.1 OF: