Community Center KrazanU-�aZM&Associates,Inc.
Geotechnical Engineering . Environmental Engineering
Construction Testing and Inspection
DATE: 4/28/2015
PROJECT* 06615047
PROJECT: Yelm Community Center
LOCATION: S01 2nd St. SE
KA P.M.: Bili Throne
FIELD
REPORT NO.: 15047DERO42815-BR
CONTRACTOR: Stetz Construction
PERMIT* 20140170
INSPECTOR: Bruce Ridgley
JURISDICTION: City of Yelm
WEATHER: Overcast TEMP: 56
Krazan and Associates on site for inspection as requested by client.
Reinforcing steel bar inspection for slab on grade and thicken footings between grids 2 through 7 / A through B
3.5 through 4.5 / B through C.
Upon arrival on site met with contractor and reviewed requirements and locations. Reinforcing was observed and
Appeared to be in place and in conformance with project plans and specifications for (Size, Grade, Lap splice, spacing)
DWG S2.01 notes and per RFI #8 and # 28.
Note: Clearances will need to be confirmed before placement of concrete.
Reviewed By:
ASTM Test #:
Equipment/Asset Numbegs):
To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements.
Superintendent/Representative:
Technician:
Offices Serving the Western United States
Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 m Puyallup (253) 939-2500
Daily Field Report Reriaion 8 Effective 0 211 3/201 3
Theih-1kwP-idedm Wn,WnTh Vag MY aol be>grodoeadmae,menetvaloftwdUmp=i—athcc1J=end X= 2&Aw6— Thi aim wdiweRre.a b sodm,u WmGiax cedwnllecCa
e-Kie- Tbl-mf elan w5objep to review 16-M Wal -haa'1 D, �ilwa6 wis--hmeda d---.1 m'Rbmiblhy fa smJidir/ a WO, "Iae same n4�snm aaa bem Nwidea h, a—an eek.
e! KrazangAssociates,Inc.
Geotechnical Engineering . Environmental Engineering
Construction Testing and Inspection
DATE: 4/29/2015
PROJECT #: 06615047
PROJECT: Yelm Community Center
LOCATION: 301 2nd St. SE
KA P.M.: Bill Throne
FIELD
REPORT NO.: 15047DFRO42915-BR
CONTRACTOR: Stetz Construction
PERMIT M 20140170
INSPECTOR: Bruce Ridgley
JURISDICTION: City of Yelm
WEATHER: Mostly Cloudy TEMP: 54'
Krazan and Associates representive on site for inspection as requested by client.
Concrete sampling and testing for slab on grade and thicken footings within slab.
Upon arrival met with contractor and reviewed placement location and requirements. The concrete was observed
Being placed via pump and adequately consolidated. Mix placed this date was #12500F from Miles. (1) set of 4x8
Cylinders were cast for compressive strength tests. For additional information refer to Krazan concrete report #
15047CR042915-BR. A total of 57cy placed this date.
Note: Clearances were maintained during concrete placement.
Note: Kitchen area to be placed at another date after reinforcing steel is installed and inspected.
Reviewed By:
To the best of my
ASTM Test M
Equipment/Asset Number(s):
the above WAS performed in accordance with the approved plans, specifications and regulatory requirements.
Superintendent/Representative.
Technician.
g it -Y-7
Offices Serving the Western United States
Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 - Puyallup (253) 939-2500
Deity Ficid Repon Revision 8 Ef .&q 02/1 Y2013
The h( dm Kmided m this rqm isX -W W the-dativeuseofeh fi t.76ia,epwt .y otth m,,& -d -i forma riWwe me w,nuar mmmu xmeaam aed Xr r ,,TM ndi—hm onwviim,na+vtma x,u. eemm si —dai—d womu«
attivme'.. 16b bf dm h��oawmY Vdir In Hoel sd,mimL 9Y sY�BNu,eOOM. muinm%dm does rolacrepl,w-pe'nvD@t'YGv wlidaYofremM1.c 73e s^the nfamaUov haeMm Novi0n7 tr: ulIlas oo ®z
Krr1�L�"aza&Associates,lnc.
Geotechnical Engineering *Environmental Engineering
Construction Testing and Inspection
DATE: 5/4/2015
PROJECT #: 66615047
PROJECT: Yelm Community Center
LOCATION: 301 2nd Street SE
KA P.M.: Bill Throne
FIELD
REPORT NO.: 15047DFRO50415-JB
CONTRACTOR: Stetz Construction
PERMIT #: 20140170
INSPECTOR: J. Bistryski
JURISDICTION: City of Yelm
WEATHER: Overcast TEMP: 61 °
& Associates, Inc. on site as requested for reinforcing steel bar inspection and concrete placement observation,
g and testing at the following locations:
- Kitchen Area — Slab On Grade
arrival on site met with contractor and reviewed plan details and inspection locations. The elements of the
rcement in the locations noted above were visually inspected and found to be in place with the correct size of bars,
.g and clearances as detailed in project plans.
to concrete was Class 3000 from Cal Portland and was observed being placed via truck chute. Consolidation was
rformed using mechanical vibration. Samples were obtained and tested from the point of placement. (1) Set of (5) 4x8
linders were cast for laboratory compressive strength testing. For additional testing information and sampling details,
Krazan Report #15047CR050415-JB.
Reviewed By:
ASTM Test #: Equipment/Asset Number(s):
To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements.
S uperintendent/Representative:
Technician:
Offices Serving the Western United States
Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Puyallup (253) 939-2500
Wdi ,Field Report RevisionB
E13'm4vc 02/19I2013
Tb,bf ;peW—Wft lh erclvsAenz ofthe ctimt. lb'I_W me, nN buMmdmadm®y Rr_tl dh tbw vrivmp="wditdiW d&-m&Nnda- Ibis tepw, hWi— m.'pa $Oben ditu atiapmdabaWdWftk dki—&WawVeM[
am,'-tix. "ibis iotdmetiw uwbpGto saiew �mi,r b+Hoel sWwtifL1 B, e�6md8 dLLsnyvS atQmtpeum do®mtan�lt pa�c�lnY @r �'�ddY OfmuM_ The®eu,Po�Nvb¢wpt�AdMolbmm&b&
♦- air a
motet. 1i1�
Krnmifrh aj; a `I .n r h� ` ,,t rR (,� Concrete Report
Number: 15047CRO42915BR
Date: 4129/2015
Project #:"066-15047
Project: Yelm Community Center
Location: 301 2nd Street SE
Krazan PM Bill Throne
Field Data
Concrete: F Slab
Supplier: I Miles
Contractor: Stetz Construction
Permit #: 20140170
Inspector: Bruce Ridgley
Jurisdiction: City of Yelm
Weather. Mostly Cloudy Temp: 50
Other I -
Plant No. 1 2068 1 Site Mix:
Slump Mix Air Unit
Time Truck # Ticket # % Air Inch Temp F Temp F Weight
10:25 1 68 1 213719 1 - 1 53/4 1 62 1 52 1 -
Placement Area
Location SLAB ON GRADE AND THICKENED FOOTINGS FOR BUILDING.
Remarks CAST (1) SET OF (5) 4X8 CYLINDERS FROM LOAD #1 (10CY)
76.40LBS OF COLOR ADDED TO MIX PER PLAN. COLOR IS
LISTED UNDER FIRST ADMIXTURE.
Please Refer To Field Repot Number: 15047DFRO42915BR
Inspector:1 B.RIDGLEY
Reported Batch DATA
Cement Type 1 1/II
Design �X Actual aX
Mix No. 1250OF 1250OF
Cern. Lbs. 489 490
F. Ash lbs. 122 121
C. Agg. Lbs 1530 1526
C. Agg. Lba 350 256
C. Agg. Lbs - -
Sand lbs 1370 1365
Water 245 lbs 231 lbs
Admixture 7.64 lbs 7.64 lbs
Admixture -
Admixture - -
Air Ent.
(OzJCWt.) Water Added On Job Site
(Gals.)
Field Test
ASTM Method
C143 X C138
C1064 X C173
C31 X OTHER
Laboratory Data Design Strength 3000 At 26 Days Date Specimens Recd 4/30/2015
Cyl.
Code
Test Field
Date Cure
A e Dim.
Area
Wt. Max Comp.
# Load Strength
Set Tested Brk
# By Typ
Test Method
ASTM C39 X
1476-1
5/6/15 -
7 4.00 12.57
- 63125
5020
1 MT 3
ASTM C109
1476-2
5127/15 -
28
-
1
ASTM C617
1476-3
5/27/15 -
28
-
1
ASTM C1231 X
1476-4
5/27/15 -
28
-
1
ASTM C1019
1476-5
-
H
-
1
AASHTO-T22
Test Results
Remarks:
Conforming
Results Reviewed By:
Date:
S i
Non -contorting
Code For Break
Types:
1 1XI
Cone
2. Cone
Split
3. Cone
Shear
4a.
Shear
coiumner
Split
Offices Serving The Western United States Cancrele Raped Re, 4 En. 10-21-00
Tha information pmNded on the raped ie prepeired for the exdud- uea of the diem, and —ynot be reproducad in any rermelwbout tho writion pa.-nizzion of the din and Kmzan 8 Aeendatns
Kr,
Date: 5/4/2015
Project M 066-15047
Project: Yelm Community Center
Location: 301 2nd Street SE
Krazan PM Bill Throne
Field Data
Concrete: F X
Supplier: I Calportland
- - fi :dr vJJ.f i5 In t,1rf �! Cs%t rn F• S
Other I-
Concrete Report
Number: 15047C R050415J B
Contractor: Stetz Construction
Permit #: 20140170
Inspector: Joe Bistryskl
Jurisdiction: City of Yelm
Weather: Overcast Temp: 51
Plant No. 1 272 Site Mix:
Slump Mix Air Unit
Time Truck# Ticket# %Air Inch Temp Temp Weight
11:45 1 7638 1 1140731 1 - 1 4 114 1 69 1 61
Placement Area
Location KITCHEN AREA - SLAB ON GRADE.
Remarks CAST (1) SET OF (5) 08 CYLINDERS FROM LOAD #1 (7.25CY)
ADMIXTURE AT RIGHT IS WRDA 64.
Please Refer To Field Repot Number: 15047D FROS0415J B
Inspector : I J.BISTRYSKI
Reported Batch DATA
Cement Type 1 1/11
Design a] Actual QX
Mix No, 63013 63013
cam. Lbs. 550 551
F. Ash lbs. - -
C. Agg. Lbs 1960 1953
C. Agg, Lba - -
C.Agg.Lbs - -
sand lbs 1330 1315
Water 250 [be 238 lbs
Admixture 15 oz 15 oz
Admixture - -
Admixture - -
Air Ent.
(Oztcwt.) -
Water Added On Job Site
(Gels.) 1=J
Field Test
ASTM Method
Age Dim.
C143
Wt. Max Comp.
# Load Strength
C138
Test Method
ASTM C39 X
C1064
TX
C173
- 61175
C31 OTHER
1 MT 3
Laboratory Data Design Strength 3000 At 28 Days Date Specimens Recd 5/5/2015
Cyl.
Code
Test Field
Date Cure
Age Dim.
Area
Wt. Max Comp.
# Load Strength
Set Tested Brk
# By Typ
Test Method
ASTM C39 X
1502-1
5/11115 -
7 4.00 12.57
- 61175
4870
1 MT 3
ASTM C109
1502-2
6/1/15 -
28
-
1
ASTM C617
1502-3
611/15 -
28
-
1
ASTM C1231 X
1502-4
6/1115 -
28
-
1
ASTM C1019
1502-5
-
H
-
1
AASHTO-T22
Test Results
Remarks:
Conforming
Results Reviewed By:
Da e:
57 - 11-15
Non -Conforming
Code For Break
Types:
12.
Cone
/ \
Cone
Split
3. Cone
Shear
/
4
Shear
zi
s. column er
Split
Offices Serving The Western United States Concrete Report Re, 4 En. 10.21.08
The information proAded on drls report is prepelred for the exdusiee rae of Itre diem, erd may mt be reproduced n any format uhhwd the written permission of the alien and Krezen _... seodates
Date: 4/15/2015
Project #: 066-15047
Project: Yelm Community Center
Location: 301 2nd Street SE
Krazan PM Bill Throne
rY ii11 uiT r Ta '!ee yt"e; r,'a T1s Concrete Report
+, +.;•: ,., r.__� Number: 15047CRO41515MM
Contractor: Stetz Construction
Permit #: 20140170
Inspector: Marty Mundy
Jurisdiction: City of Yelm
Weather: Sunny Temp: 55
Field Data
Concrete: �� - Other
Supplier: Miles Plant No. 2068 Site Mix:
Slump Mix Air Unit
Time Truck # Ticket # % Air Inch Temp F Temp F weight
12:55 1 M077 1 213369 - 1 5 1 64 1 55 1 -
Placement Area
Location SLAB
GRADE AT GRIDLINES 1 -2/A -B
Remarks
Please Refer To Field Repat Number: 150470FR041515MM
Inspector:1 M.MUNDY
Reported Batch DATA
Cement Type I Ill l
Design F X] Actual
Mix No. 1250OF 1250OF
Cam. Lbs. 489 494
F. Ash lbs. 122 121
C.Agg.Lbs 1530 1509
C. Agg. Lbs 350 362
C. Agg. Lbs - -
Sand Ibs 1370 1378
Water 213 213
Admixture - -
AdmixtJre -
Admixture
Air Ent
(Ozlcwt.y - -
Water Added On Job Site
(Gals.) 10
Field Test
ASTM Method
C143 X C138
C1064XI C173
X
C31 OTHER
Laboratory Data Design Strength 1 3000 At 28 Days Date Specimens Recad 4!1612015
Cyl.
Code
Test Field
Date Cure
Age Dim.
Area
Wt. Max Camp.
# Load Strength
Set
#
Tested
By
Birk
Typ
Test Method
ASTM C39 X
1422-1
4/22/15 -
7 4.00 12.57
- 48280 3840
1
JS
3
ASTM C109
1422-2
5/13/15 -
28 4.00 12.57
- 71130 5660
1
MT
3
ASTM C617
1422-3
5/13/15 -
28 4.00 12.57
- 71180 5660
1
MT
3
ASTM C1231 X
1422-4
5113115 -
128 4.00 12.57
- 70025 5570
1
MT
3
ASTM C1019
1422-5
-
H
-
1
AASHTO-T22
Test Results
Remarks:
X Conforming
Results Reviewed By:
Date:
1
— J
Non -Conforming
Code For Break
Types:
12.
Cone
/ \
Cone
Split
3. Cone
Shear
/
4
Shear
/
5. Columnar
Split
Offices Serving The Western United states Concrete Report Re, 4 Eff. 10-21-0e
The information provided on lhm report is prepalred for the exeYbWe use of the tiers, an 1 may rot be reproduoed in any format without the written permission of the digin and Kramn A Associates
�. IAI r
_.`
Date: 4/29/2015
Project* 066-15047
Project: Yelm Community Center
Location: 301 2nd Street SE
Krazan PM Bill Throne
Field Data
Concrete: Slab
Supplier: Miles
t Concrete Report
NiCie2+3�c<<inrkr
r: •t :. , . ;:..__o, Number: 15047CRO42915BR
Contractor: Stetz Construction
Permit #: 20140170
Inspector: Bruce Ridgley
Jurisdicdon: City of Yelm
Weather: Mostly Cloudy Temp: 50
Other I -
Plant No. I 2066 Site Mix:
Slump Mix Air Unit
Time Truck # Ticket # % Air Inch Temp F Temp F Weight
10:25 1 68 1 213719 1 - 1 5 314 1 fit 1 52 1 -
Placement Area
Location SLAB ON GRADE AND THICKENED FOOTINGS FOR BUILDING.
Remarks CAST (1) SET OF (5) 4X8 CYLINDERS FROM LOAD #1 (10CY)
76.40LBS OF COLOR ADDED TO MIX PER PLAN. COLOR IS
LISTED UNDER FIRST ADMIXTURE.
Please Refer To Field Repot Number: 15047DFR042915BR
Inspector: I B.RiDGLEY
Reported Batch DATA
Cement Type UI I
Design
a Actual EKI
MIXNo,
1250OF 1250OF
Cam. Lbs.
489 490
F. Ash lbs.
122 121
C. Agg, Lbs
1530 1526
C. Agg, lbs
350 256
C. Agg. Lbs
- -
sand lbs
1370 1365
water
245 lbs 231 lbs
Admixture
7.64 Ito 7.641bs
Admixture
- -
Admixture
-
Air Ent.
3
( oz I CWt.)
1476-4
Water Added On Job Site
28 4.00 12.57
(Gals.) o
Field Test
ASTM Method
C143 X C138
C1064 X C173
C31 1 X I OTHER
Laboratory Data Design Strength 1 3000 At 28 Days Date Specimens Recd 4/30/2015
Cyl-
Code
Test FieldWt.
Date Cure
Age Dim.
Area
Max Comp.
# Load Strength
Set Tested
# By
Brk
Typ
Test Method
ASTM C39 X
1476-1
516115 -
7 4.00 12.57
- 63125 5020
1 MT
3
ASTM C109
1476-2
5127115 -
28 4.00 12.57
- 80855 6430
1 JS
3
ASTM C617
1476-3
5/27/15 -
28 4.00 12.57
- 77220 6140
1 JS
3
ASTM C1231 X
1476-4
5/27/15 -
28 4.00 12.57
- 79400 6320
1 JS
3
ASTM C1019
1476-5
-
H
-
1
AASHTO-T22
Test Results
Remarks:
Ad
X Conforming
Results Reviewed By:
n.4-
y_ f
I-
Non -Conforming
Code For Break
Types:
1
Gone
X
/ \
2, Cone
Soli[
3. Cone
Shear
/
,X
Shear
If.column r
Split
Offices Serving The Western United States Concrete R.d rt Rev.4 EH. 10-21-08
The Infammtfon p—idad an thl, rapart %prepamd for the exdudn uw of the diart, and may not be repmdumd in any farmet wahout the written t*,,n%Mon of the digin and Kmmn & Associatee