20190071 Permit Pkg (4)ROOF ASSEMBLIES TABLE R905.1.1(2 UNDERLAYMENT APPLICATION ROOF COVERING SECTION MAXIMUM ULTIMATE DESIGN WIND SPEED, V„ rt < 140 MPH MAXIMUM ULTIMATE DESIGN WIND SPEED, V„„ >_ 140 MPH For roof slopes from two units vertical in 12 units horizontal (2:12), up to four units vertical in 12 units horizontal (4:12), underlayment shall be two layers applied in the following manner: apply a 19 -inch strip of underlayment felt paral- lel to and starting at the eaves. Starting at the eave, apply 36 -inch -wide sheets of underlay- ment, overlapping successive sheets 19 inches. Distortions in the underlayment shall not inter- Same as Maximum Ultimate Design Wind Speed, Asphalt shingles R905.2 fere with the ability of the shingles to seal. V„1< < 140 mph except all laps shall be not less For roof slopes of four units vertical in 12 than 4 inches. units horizontal (4:12) or greater, underlayment shall be one layer applied in the following man- ner: underlayment shall be applied shingle fash- ion, parallel to and starting from the eave and lapped 2 inches, Distortions in the underlayment shall not interfere with the ability of the shingles to seal. End laps shall be 4 inches and shall be offset by 6 feet. For roof slopes from two and one-half units ver- tical in 12 units horizontal (21/2:12), up to four units vertical in 12 units horizontal (4:12), under- layment shall be a minimum of two layers applied as follows: starting at the eave, apply a 19 -inch strip of underlayment parallel with the eave. Starting at the eave, apply 36 -inch -wide strips of Same as Maximum Ultimate Design Wind Clay and concrete tile R905.3 underlayment felt, overlapping successive sheets Speed, Vu„ < 140 mph except all laps shall be not 19 inches. less than 4 inches. For roof slopes of four units vertical in 12 units horizontal (4:12) or greater, underlayment shall be a minimum of one layer of underlayment felt applied shingle fashion, parallel to and starting from the eaves and lapped 2 inches. End laps shall be 4 inches and shall be offset by 6 feet. Metal roof shingles R905.4 For roof slopes from two units vertical in 12 units horizontal (2:12), up to four units vertical in 12 units horizontal (4:12), underlayment shall Mineral -surfaced roll R9055 be two layers applied in the following manner: roofing . apply a 19 -inch strip of underlayment felt paral- lel to and starting at the eaves. Starting at the Slate and slate -type R905.6 eave, apply 36 -inch -wide sheets of underlay - shingles Apply n accordance with the manufacturer's PPYi installation instructions. ment, overlapping successive sheets 19 inches, and fastened sufficiently to hold in place. Wood shingles R905.7 For roof slopes of four units vertical in 12 units horizontal (4:12) or greater, underlayment shall be one layer applied in the following man - Wood shakes R905.8 ner: underlayment shall be applied shingle fash- ion, parallel to and starting from the eave and lapped 4 inches. End laps shall be 4 inches and Metal panels P R905.10 shall be offset by 6 feet. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. 2015 INTERNATIONAL RESIDENTIAL CODE® 415