Loading...
20090078 Yelm Letter10.28.09 To: Terry Hetland Re: Job#08-5054 Yelm Batting Cages Window and Bolt Clarifications To Whom It May Concern: 1. Windows, doors, vents, ect., provided by ATY Building Systems, Inc., are accessory products designed to be field located. Therefore, their locations are not reflected on PEMB drawings. They do not effect the structural design and are approved for use with PEMB when installed to manufacturers specification, provided. The windows in question, two (2) 6040 Hor Insul, are self framing and are supported by the wall sheeting. As long as no wall girts have been altered for installation, said windows are acceptable. 2. The standard for tightening of joint connections for column to rafter and rafter to rafter is Snug-Tightened Joints in accordance with the Research Council on Structural Connections. Please refer to the "Specifications for Structural Joints Using ASTM A325 or A490 Bolts", Sections 4.1, 6.1, 9. 1, provided. Please call with any questions. Regards, Terry Puccini Architect ATY Building Systems, Inc. Illinois Office: 1315 E. Park St. - Taylorville, 1L 62568 To// Free - 800.487.8171 - Loco? - 217.7183990 Fox - 217.824.9712 Colorado Office: P.O. Box 22976 - Denver, CO 80222-0976 ToU.,"rep-800.761,6199. Locol-301922,5111 Fox -- 303.9215160 wwwzty steel builditigs.com