20090078 Yelm Letter10.28.09
To: Terry Hetland
Re: Job#08-5054
Yelm Batting Cages
Window and Bolt Clarifications
To Whom It May Concern:
1. Windows, doors, vents, ect., provided by ATY Building Systems, Inc., are accessory
products designed to be field located. Therefore, their locations are not reflected on
PEMB drawings. They do not effect the structural design and are approved for use with
PEMB when installed to manufacturers specification, provided. The windows in
question, two (2) 6040 Hor Insul, are self framing and are supported by the wall sheeting.
As long as no wall girts have been altered for installation, said windows are acceptable.
2. The standard for tightening of joint connections for column to rafter and rafter to rafter
is Snug-Tightened Joints in accordance with the Research Council on Structural
Connections. Please refer to the "Specifications for Structural Joints Using ASTM A325
or A490 Bolts", Sections 4.1, 6.1, 9. 1, provided.
Please call with any questions.
Regards,
Terry Puccini
Architect
ATY Building Systems, Inc.