Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
08-0074 Bldg B Fire Alarm Overview 031308 001 bad file
:. TABLE OF CONTENTS 1. COPY OF APPL/CAT/ON (1 PAGE1 2. SCOPE OF WORK (1 PAGE1 3, MAP OF LOCAT/ON (1 PAGEI 4. M/RCOM FX-2000 SPEC SHEETS (1 O PAGESI 5, M/RCOM SMOKE AND HEAT DETECTOR SPEC SHEETS (2 PAGESI 6, M/RCOM PULL STAT/ON SPEC SHEETS (2 PAGESI 7, WHEELOCK ZNS & ZRS HORN/STROBE AND STROBE SPEC SHEETS (4 PAGES) B. WHEELOCK RSSWP OUTDOOR STROBE SPEC SHEETS (Z PAGESI 9, WHEELOCK OUTDOOR BELL SPEC SHEETS (Z PAGESI G RECEIVED NAR 13 2008 FIRE ONE, INC. 1 ^7 WASHIINGTON BLVD. ALGONA WA, 98001 206-575-0331 F,4x - 253-735-4976 SCOPE OF WORK FOR: BERNETT RD. BLDG. B 9144 BERNETT RD. SE YELM WA, 98597 OVERVIEW THE SCOPE OF TH/S PROJECT /S TO /NSTALL A NEW F/RE ALARM CONTROL PANEL (F.acP), ADD /N/T/AT/NG DEV/CES TO THE FRCP AND ADO /ND/CAT/NG DEV/CES TO THE FRCP, FOR THE PURPOSE OF NEW CONSTRUCT/ON BU/LD/NG F/RE ALARM PROTECT/ON. CONTROL PANEL: THE CONTROL PANEL W/LL BEAM/RCOM FX-2006- 1 Z W/TH AN /NTEGRATED DUAL L/NE D/G/TAL D/ALER. WIRING: ALL W/R/NG W/LL BE FPLP RATED AND S/ZED AS FOLLOWS: /N/T/AT/NG C/RCU/TS W/LL BE AWG 1 6 OR GREATER /NO/CAT/NG C/RCU/TS W/LL BE AWG 14 OR GREATER INSTALLATION: /NSTALLAT/ON W/LL BE PERFORMED /N ACCORDANCE W/TH NFPA 70, NFPA 72 AND APPLICABLE PROV/S/ONS OF THE WASH/NGTON ADM/N/STRAY/ON CODE. TECHN/C/ANS FROM F/RE ONE, /NC., CERT/F/ED BY THE STATE OF WASH/NGTON AND UNDER PERM/T BY THE AUTHOR/TY HAV/NG JUR/SO/CT/ON W/LL PERFORM ALL /NSTALLAT/ON. TESTI N G AND WARRANTY: A COMPLETE TEST W/LL BE PERFORMED /N THE PRESENCE OF THE OWNER, AND ANY OTHER AUTHOR/TY HAV/NG JUR/SD/CT/ON DEEMED APPROPR/ATE. FOLLOW/NG AN ACCEPTABLE TEST RESULT, THE OWNER AND F/RE ONE, /NC. W/LL SET THE TERMS FOR WARRANTY SERV/CE ANO ARRANGE A CONE/DENCE TEST/NG SCHEDULE. F/RE ONE, /NC. W/LL PROV/OE SYSTEMS TRA/N/NG TO THE OWNER TO ENSURE PROPER OPERAT/ONS. 0 9144 Burnett Rd SE, Yelm, WA 98597, USA - Google Maps Page 1 of 2 Address 9144 Burnett Rd SE ~~ Yelm, WA 98597 Ma s ~btlih Ave SE ~ _ _ ..... rlStA Ave_SE . 4 ~~ ~ .. ~ rn V t 1 € g-_ Prwrr vmta Loon < t S C G se- ... Pr m m.._. . ,._..._. d_rZr m ~^' Sttt ~o~o_ -'- x c .~~ ~ n -t.. ~! i m 316 ~ ~. y ' ` '~ I ~ m a j SF . "~ ~ j ~ ~\ sc~~ s ~v -- _ ~ Dam Ave SE ~B3rd Ave SE ~-~- .. __._ 510 '~_ Lv p i S' e ~9~ e N m C2rA8 GOO0k • Map data 02008 NAVTEO^' • Teimx of Use r, . _.,, A A ~ ri____ _~~ ~ n a ~ or. ~ v,.i.... -~t~ n ~nocn~ it is n ~.~.,- iii ni~nnQ ' ~.. I<tirtGo~~ ~ .66. `,~~xco~zcxz l~ Description Mircom's FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements while also providing easy installation and operation at a cost- effective price. The FX-2000 base panel consists of one intelligent analog loop controller capable of supporting 99 Analog Sensors and 99 Addressable Modules which can be wired in ClassA (Style 6 or 7) or Class B (Style 4). The system can be expanded by adding additional Analog Loop Controller Modules. In addition the base panel supports 16 conventional hardwire adder modules such as the DM-1008A Initiating Circuit Module, SGM- 1004A Indicating Circuit Module and the RM-1008A Relay Circuit Module. Additional conventional hardwire adder modules can be added with the ALC-H16 Adder Hardwire Loop Controller Module, which allows the system to support an additional 16 conventional adder modules. The base panel also consists of 4 Class A/B (Style Z/Y) Indicating Circuits rated at 1.7 Amps each and either a 6 or 12 Amp Power Supply. Equipped with a large 4 x 20 Back-lit Alphanumeric LCD display, the FX-2000 utilizes a simple Menu system complete with a directional keypad, common control switches and LEDs, Alarm Queue switches and LEDs, two configurable input switches and 16 configurable zone LEDs. Large system capacity Modular design Each Analog Loop is capable of supporting 99 Analog Sensors and 99 Addressable Modules which can be wired in Class A (Style 6 or 7) or Class B (Style 4) Base system supports 16 conventional hardwired modules with the provision to add more using theALC- H16Hardwire Loop Controller Module 6 or 12 Amp power supply Four Class A/B (Style Z/Y) Indicating Circuits rated at 1.7 Amps each Configurable for Two Stage operation Three level password protection with field programmable definition which enables the installer to determine what functions are accessible for each password level Panel Security to protect site configurations Manual Control Enable which allows password protection for all front panel function switches Correlatable Switch Inputs which allows for multi- functional outputs FourAlarrn Queues with selector switches and LEDs for Alarm, Supervisory, Monitor and Trouble Auxiliary relay contacts for Common Alarm, Common Supervisory and Common Trouble RS-232 output for remote system printer or CRT Two Event History Logs comprised of a 1000 Alarm History Log for alarm related events and a 2000 Event Log for all events Front Panel Auto-Configure and/or Computer laptop Programmable Large 4 by 20 character Back-lit LCD Display with user friendly menu Common Control switches and/or indicating LEDs for System Reset, Signal Silence, Fire Drill, Acknowledge, General Alarm, Lamp Test, A.C. On, Pre-Alarm and Ground Fault Built-in One Man Walk Test operation Configurable for Coded Operation 16 zone configurable LED annunciator complete with individual slide-in labels for zone definition Supports an RS-485 interface to the QX-5000 Voice Evacuation System Panel selection for Canadian (ULC) or U.S.A. (UL) requirements for smoke sensors (sensitivity) via computer laptop Capability to adjust Intelligent Smoke Detector sensitivity level FM ~' Noa~o City of UL U~~ :rte' 3013980 Chicago ' IV p~~~J M EA Class I (Con) E15095 Class II ((ApCon))) E15096 57010 S7010 71651477:111 approved Class II(Add) E150 8 7170-1477:119 313-97-E Highrise CATALOG NUMBER 59,E 0 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Features Operation The FX-2000 is field programmable via the front panel auto configuration or a laptop computer. In addition, it allows for a three level password protection that can be field defined via a laptop computer. This unique feature allows the installer to determine what functions are accessible for each password level. The system is also equipped with two Event History Logs; one for Alarm and the other for full panel sequence events. The Alarm History Log (1000 events) contains all alarm related functions while the Event Log (2000 events) provides a full sequence log of all operations, as well as alarms and troubles. Both Event History Logs can be used during the One Man Walk Test operation. This allows the event logs to be downloaded to a laptop or printer for a permanent record. The FX-2000 is a very flexible system which supports both internal and external annunciation modules. The internal annunciation modules consist of the RAX-1048 Programmable Zone LED Annunciator, the IPS-2424 Programmable Input Switches Module, the FDX-008 Fan Damper Module and theAGD-048 Adder Graphic Driver Module. Input Correlations All input circuits (addressable or hardwired) can be configured for non-verified alarm, verified alarm, waterflow, latching/non-latching supervisory, monitor, trouble only or remote switch inputs. All of the input configuration types listed above, with the exception of remote switch can be programmed to operate relays, signal and strobe circuits for hardwired or addressable devices. Please refer to the chart below for correlations. The input circuits configured asnon- latching will cause the output circuits configured to them to follow the state of the input device. This feature allows for the connection of multiple panels together for signal operation. All of these modules mount within the panel and are driven from the main LCD display. The extemal annunciator modules include the RAM-1032 and RAX-1048 LED Remote Annunciators, the MGD-32 Master Graphic Driver Module, the MGDS-16/16 Master Graphic Driver Module and the RAX-LCD Remote LCD Shared Display. The RAX-LCD Remote LCD Shared Display provides the same features as the main display on the FX-2000. In addition the RAX-LCD also acts as a driver module that allows forthe RAX-1048, IPS-2424, FDX-008 andAGD-048 to be connected to it. The RAX-LCD is required as a driver module any time any of the above mentioned external annunciator modules are programmed differently from those on the main panel or are mounted remote from the main panel. In addition to these adder modules, the FX-2000 also supports the UDACT-300A Digital Communicator Module and the PR-300 Polarity Reversal/City Tie Module. The FX-2000 also supports an RS-485 interface to the QX-5000 Emergency Zoned Audio System. The Remote Switch input, which must be momentary, allows any input tyke device (addressable or hardwired) to be configured as a common control functions such as fire drill, system reset, signal silence etc. The remote switches operate in a momentary mode like the control switches on the FX- 2000 main panel. For functions such as fire drill, the remote switch functions in a toggle mode, with one press for "on" and one press for "off'. The remote switch is supervised for"stuck in on"positions, where the switch input is activated (stuck) for more than 30 seconds. If this occurs, a trouble is generated and clears when the input goes away. Intelligent or Conventional Output C l S i h Input Types Relay Signal Strobe ontro w tc es Non-Verified Alarm Yes Yes Yes No Verified Yes Yes Yes No Waterflow Yes Yes Yes No Non-Latching Supervisory Yes Yes Yes No Latching Supervisory Yes Yes Yes No Monitor Yes Yes Yes No Trouble Only Yes Yes Yes No Remote Switch Input No No No Yes CAT. 5910 PURPOSES. page 2 of 10 FX-2000 Standard Series FX-2003-6/FX-2003-12 Compact Main Chassis The FX-2003-6/FX-2003-12 Compact Main Chassis comes complete with one Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and either a 6 Amp Power Supply which charges 10-24 AH batteries or a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2003-6/FX- 2003-12snpports 16 conventional adder modules and provides space for 3 adder modules. The FX-2003- 6/FX-2003-12 mounts in the BBX-1024 enclosure. FX-2017-12A Mid-Size Main Chassis The FX-2017-12A Mid-Size Main Chassis comes complete with one Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2017- 12A supports 16 conventional adder modules and has space for up to 17 adder modules and 3 internal annunciator adder modules. The FX-2017-12Amounts in the BBX-1072A enclosure. FX-2009-12 Large Size Main Chassis The FX-2009-12 Large Size Main Chassis comes complete with one Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2009-12 supports 16 conventional adder modules and provides space for up to 9 adder modules and 2 internal annunciator adder modules. The FX-2009-12 mounts in the BB- 5000 Series enclosures. ECX-0012 Expander Chassis The ECX-0012 Expander Chassis for the FX-2009-12/ FX-2009S-12 supports up to 12 adder modules and has space for 2 internal annunciator modules. The ECX- 0012 mounts in the BB-5000 series enclosures. FX-2000 Standard Series System Maximums • 500 Input Circuits • 150 Output Circuits • 5 IntelligentAddressable Loops • 4 Remote LCD Annunciators • 4 Main LED Annunciators • 100 Manual Control Switches NOTE: Refer to page 4 for Enhanced Series Maximums M' NOT TO BE USED FOR WSTAlLAT10N PURPOSES. CAT. 591 O ~`~/`~ COM .+ page 3 of 10 FX-2000 Enhanced Series Mircom's FX-2000 Enhanced Series feature a powerful CPU which increases the processing of inputs/outputs to provide faster response times and allow for larger FX-2003S-12 Enhanced Series Compact Main Chassis The FX-2003S-12 Enhanced Compact Main Chassis comes complete with 4 Class A/B (Style Z/1~ Indicating Circuits (1.7 Amps each), a 4 line by 20 character back- lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2003S-12 provides space for 3 ALC-396S Dual Loop Controller Modules. The FX-2003S-12 mounts in the BBX-1024 enclosure. ECX-0012 Expander Chassis The ECX-0012 Expander Chassis for the FX-2009-12/ FX-2009S-12 supports up to 12 adder modules and has space for 2 internal annunciator modules. The ECX- 0012 mounts in the BB-5000 series enclosures. FX-2017S-12A Enhanced Series Midsize Main Chassis The FX-2017S-12A Mid-Size Main Chassis comes complete with 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2017S-12A provides space for up to 17 adder modules/Dual Loop Controllers and 3 internal annunciator adder modules. The FX-2017S- 12Amounts in the BBX-1072A enclosure. FX-2009S-12 Enhanced Series Large Size Main Chassis The FX-2009S-12 Enhanced Large Size Main Chassis comes complete with 4 ClassA/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2009S-12 electrically supports 16 conventional adder modules and provides space for up to 9 adder modules and 2 internal annunciator adder modules. The FA-2009S-12 mounts in the BB-5000 Series enclosures. FX-2000 Enhanced Series System Maximums • 1500 Input Circuits • 300 Output Circuits • 30 Intelligent Addressable Loops • 24 Remote LCD Annunciators • 4 Main LED Annunciators • 300 Manual Control Switches /~~~`/ ~'~®~y NOT TO BE USED FORINSTALLATIONPURPOSES. CAT. 5910 page 4 of 10 system capacities. The Main Chassis are available in the same configurations as the standard FX-2000 Series. Adder Loop Controller Modules Adder Hardwire Modules ~ J~ r ~ ` ~J r~ d J cl _~ ~~~ :-~t~s....ca. rw. i ALC-198S Single Analog Loop Controller Module The ALC-198S Single Analog Loop Controller Module provides an additional analog loop to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules. The ALC-198S occupies one module slot in the FX-2000 main or expander chassis. DM-1008A Eight Initiating Circuit Module The DM-1008A provides 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits configurable for Alarm, Supervisory orTroublezones. The DM-1008A occupies one module slotinthe FX-2000 main orexpanderchassis. ALC-396S Dual Analog Loop Controller Module The ALC-396S Dual Analog Loop Controller Module provides two additional analog loops to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules per loop. The ALC-396S occupies one module slot in the FX-2000 main or expander chassis. :~ ,~> ~i ~ ~ - --~ ~ I ~T - ' ~~ iII[' v ~ ~~. ~^ .. ; f ~, la:. .:IF~,'i: ALC-H16 Hardwire Loop Controller Module TheALC-H16 Hardwire Loop Controller Module allows the FX-2000 to support an additional sixteen (16) conventional hardwire adder modules. The hardwire modules consist of the DM-1008 Eight Initiating Circuit Module, SGM- 1004 Four Indicating Circuit Module and the RM-1008 Eight Relay Circuit Module. TheALC-H16 occupies one module slot in the FX-2000 main or expander chassis. Adder Auxiliary Modules SGM-1004A Four Indicating Circuit Module The SGM-1004A provides 4 Class A/B (Style Z/1') Indicating Circuits configurable as Silenceable or Non-Silenceable. Each Indicating Circuits is rated at 1.7 Amps. Each of the indicating circuits have individual signal silence inputs which are jumper selectable. The SGM-1004A occupies one module slot in the FX-2000 main or expander chassis. RM-1008A Eight Relay Circuit Module The RM-1008A provides the FX-2000 with 8 individual configurable relays per module. Each relay provides one Form C contact rated at 28 VDC @1 Amp (resistive load). The RM-1008A occupies one module slot in the FX-2000 main or expander chassis. t r I •i y - "t. UDACT-300A Digital Alarm Communicator Module The UDACT-300A Digital Alarm Communicator Module allows the FX-2000 to transmit addressable point information to a central station. The UDACT 300A can be configured locally via the on-board keypad and the CFG- 300 Configuration Tool or with a UIMA programming tool and a computer with an available serial or USB port. The UDACT-300A occupies one module slot in the FX-2000 main or expander chassis. PR-300 Polarity Reversal/City Tie Module The PR-300 Polarity Reversal/City Tie Module provides the system with a supervised City Tie (24 VDC/200 mA max.) and Polarity Reversal connection (24 VDC (open circuit), 8 mA max. (shorted)). The PR-300 mounts in the FX-2000 main chassis. ~~! !/ ~ NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 59~ 0 ///~{/(i MI~OM page5or10 Programmable Modules a RAX-1048 Programmable Zone LED Annunciator Module The RAX-1048 Programmable Zone LEDAnnunciator Module provides 48programmable bi-coloured LEDs. The RAX-1048 connects to the main panel or the RAX-LCD Shared Display when mounted remotely. The RAX-1048 occupies one display position in the BB-1000 or BB-5000 enclosures. FDX-024 Fan Damper Module The FDX-024 Fan Damper Module provides 24 individually programmable switches which can be used for fan or damper control. Each circuit has 24 Bi-Coloured LEDs (Green/Amber) and 24 Amber Select LEDs. The FDX-024 connects to main panel or the RAX-LCD when mounted remotely.The FDX- 024 occupies one display position in the BB-1000 or BB-5000 enclosures. FDX-008 Fan Damper Module The FDX-008 Fan Damper Module provides individually programmed circuits which can be used for fan or damper control. Each circuit has aslide-in label, a three position selector switch, green "run or open" LED and an amber "off or closed" LED. The three-position selector switch has a centre "auto" position, a left "off or close" position and a right "on or open" position. The FDX-008 connects to the main panel or the RAX- LCD when mounted remotely. It uses MIX-M5000H for control of fans or dampers and two MIX-M501Afor status. The FDX-008 occupies one display position in the BB-1000 or BB-5000 enclosures. III ~ 'VI IPS-2424 Programmable Input Switches Module The IPS-2424 Programmable Input Switches Module provides 24 programmable switches that can be configured for ancillary functions such as zone bypass or added common control functions. The switches operate in a toggle operation with one press for "on" and one press for "off". The IPS-2424 connects to main panel or the RAX-LCD when mounted remotely. The IPS-2424 occupies one display position in the BB-1000 or BB-5000 enclosures. Electrical Ratings Current Consumption Model Standby Alarm FX-2003-6/FX-2003-12 230 mA 380 mA FX-2017-12A 230 mA 380 mA FX-2009-12 230 mA 380 mA ALC-198S/ALC-396S 35 mA 50 mA ALC-H16 35 mA 50 mA DM-1008A 80 mA 100 mA SGM-1004A 35 mA 150 mA RM-1008A 25 mA 150 mA PR-300 50 mA 300 mA UDACT-300A 40 mA 60 mA RAX-LCD 100 mA 150 mA IPS-2424 10 mA 144 mA FDX-008 10 mA 100 mA MGD-32 35 mA 1.6 Amps AGD-048 25 mA 2.4 Amps RAM-1032 50 mA 150 mA RAX-1048 15 mA 100 mA M'~O~ ~ NOT To BE uSED FOR WSTALLATION PURPOSES. CAT. 591 O ~~~~~!/ page 6 of 10 C Remote Annunciators RAX-LCD Remote Shared Display The RAX-LCD Remote Shared Display is a remote annunciator that provides the same functions as the main display on the fire alarm control panel, less the 16 zone LEDs. In addition to operating as a remote annunciator, it can also be used as a driver module for standard LED annunciation or reduced zone annunciation (different from the main panel annunciation), graphicdriversprogrammed differentfrom the main annunciators, programmable switch modules with a unique configuration and fan damper control also with a unique configuration. Each time a different type of annunciation configuration is needed an additional RAX-LCD is required. The RAX-LCD occupies one display position in the BB-1000 or BB-5000 enclosures. RAM-1032 Main Remote LED Annunciator The RAM-1032 Main Remote LED Annunciator provides common annunciator functions and 32 points of LED annunciation. Each display point can be identified by the slide-in label that slides in beside the LED. The RAM- 1032 is equipped with sealed membrane-like buttons for Common Control functions. The RAM-1032 allows for the control switches to be disabled on a per function basis for areas that do not require certain common control functions to be remotely located from the fire alarm control panel. The RAM-1032 can be programmed differently than the main panel annunciator or a remote RAX-LCD. All RAM-1032 remote annunciators on the system must be programmed the same. The RAM-1032 occupies one display position in the BB-1000 or BB-5000 enclosures. ' L- ~~L_._._ H_s ~ - _ ~9 ~~ ~ d ~.: .~- RAX-1048 Adder Remote LED Annunciator The RAX-1048 Adder Remote LED Annunciator provides an additional 48 points of LED annunciation. The RAX-1048 is an expandible module that connects to the RAM-1032. The RAX-1048 occupies one display position in the BB-1000 or BB-5000 enclosures. ~I~//~i MI^~~~y NOT Graphic Annunciator Driver Modules 1~~, .~- ,, =; r~ '.,sue,,,,.-` rr ~ t. e ~ ,~ .~, ~ ,i t( 'S.~`~` ,,~,,~k ~ s ~ 1 ~j•Y ~ w~J MGD-32 Master Graphic Driver Module The MGD-32 Master Graphic Driver Module provides common control inputs for the common control switches such as System Reset, Signal Silence, Auxiliary Disconnect, Fire Drill, Lamp Test, Acknowledge and General Alarm. Any or all of these switch inputs can be used. There are supervised outputs for all of the support LEDs and the common control switches. The MGD-32 can also drive up to 32 supervised outputs. These output points are capable of driving LEDs or incandescent lamps. Mounts in a graphic annunciator wallbox or in the BB-5000 enclosures. External power supply required for incandescent lamps and lamp test. AGD-048 Adder Graphic Driver Module The AGD-048 Adder Graphic Driver Module can be used with either the MGD-32 or MGDS-16/16 Master Graphic Driver modules, or if located remotely it must be connected and mounted with the RAX-LCD Shared Display. The AGD-048 will support an additional 48 supervised outputs. As with the master modules, the AGD-048 will support both LEDs and incandescent lamps. Mounts in a graphic annunciator wallbox or in the BB-5000 enclosures. NOTE: The combined total of RAM-1032 and MGD-32 per system is eight. All RA-1000 Series annunciators or Graphic driver modules must have the zoned LED orgraphic LED correlated to the same combination ofaddressable devices orhardwired zones . However, the zoned LED annunciator on the FX- 2000 main panel can be programmed differently from the annunciators mounted remotely. CAT. 5910 page 7 of 10 Enclosures BBX-1024 The BBX-1024 enclosure is capable of handling one FX- 2003-6 or FX-2003-12 Compact Main Chassis and up to 17AH Batteries. The FA-UNIV TRB Semi-Flush Trim Ring is required for semi- flush mounting. The cabinet features the universal CAT 30 lock and a removable door for easy installation and servicing. The cabinet is available in a beige or red exterior (BBX-1024R). Dimensions: 26"H x 14 1/2"W x 4 1/2"D ~,,,~, fil'F_~D~[QC~ ~~ ~~~ c~c.=oom occ~oo - -:srr_ ~~~~ ~~ ao°°~~ ~ o G~i~i~i~g B B-5008 The BB-5008 is a lobby control centre enclosure which is capable of handling one FX-2009-12 Large Main Chassis which supports 2 internal annuciator modules such as the IPS-2424, FDX-008, RAX-1048, etc. In addition the BB-5008 allows for 4 footprints for mounting Audio Lobby Control modules, Fire Fighter's Lobby Control modules and FX-20001ntemalAnnunciatormodules. The cabinet hold up to 24AH batteries. Door and Chassis hardware are ordered seperately. Dimensions: 36"H x 30"W x 7"D BBX-1072A The BBX-1072A enclosure is capable of handling one FX-2017-12A Mid-Size Main Chassis, as well as up to 40 AH Batteries. The cabinet features the universal CAT-30 lock and a removable door for easy installation and servicing. The cabinet is available in a beige or red exterior (BBX-1072AR). Dimensions: 32 1/2"H x 25°W x 6112"D -~ °o°~ ~~~ a ~ I~~ a~ ~~``-"W~i ~ (~o~~ccc Gc '"cc'• ra- ~~ °1 --- - - ~~ ~=~~ ~ - ~~GO° '~~~iJ~~ - ~ r~-- ~ ~:~ ~`p~ ~~~ coo coo OGOOO G'C:OO~ ~_ OGGG ~ ~~ ~ ~; GC'oLL ~~ 'I r ~ I = ~_ ------ a~``°~o~ ~~$ BB-5014 The BB-5014 is a lobby control centre enclosure which is capable of handling one FX-2009-12 Large Main Chassis which supports 2 intemal annuciator modules such as the IPS-2424, FDX-008, RAX-1048, etc. In addition the BB- 5014allows for 10 footprints for mounting Audio Lobby Control modules, Fire Fighter's Lobby Control modules and FX-2000 Internal Annunciator modules. The BB- 5014can also support a graphic annunciator in place of these modules. The cabinet holds up to 24AH batteries. Door and Chassis hardware are ordered seperately. Dimensions: 60"H x 30"W x 7"D Other Enclosures BB-1001:9"H x 12.75"W x 1.2"D BB-1002: 18"H x 12.75"W x 1.2"D BB-1003: 26.4"H x 12.75"W x 1.2"D ~ BB-1008: 33"H x 22.5"W x 1.25"D BB-1012: 45"H x 22.5"W x 1.25"D ~`~``~ Mi~~M ~ NOTTO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 8 of 10 Typical FX-2000 Panel Wiring Class B (Style 4} Grapfdc Amunciatu ~` ~ Wd~aOX rJw graphic 88.1001 enclosure rJw RAM•1032 snnundatm. MGD-72 Master Graphic Driver mMute and AGO-04a ~~ Graptzc Dever LED Annunciator modwes M500X © F MSOOM Conventional Heat Sensors l P ll S d M ti an anua ons u ta t- --LJ ~~ 4th Floor ---t-- - I------------------ ---- I I L ~ ~ 88.5008 enclosure dw RAX•LCD. _ RAX-048, IPS•2424 and FDX-048. I - ~ ~"~ C"rails I sa4 I ~ ~ ~ ~ M500S ~ ~~ X M500S 2 Pair M502M I MSOOX F Q p p p F 3rd Floor -- -~- -- - t------------------ ----- 21 VDC Rorer Non ResettaWe Power t- BB-1003 enclosure clw 21 voc ~ RAX-LCD. RAX-048 and Riser _C- -~ IPS-2424 Reservable Power I ("~ - - I I Conventional devices ~~ffX" CcnveMional Flardrried Indicating Cacult e2 t I • • /~ /~ ^ ^ ~~ lr.--1, (~--~), ,'~-!) '-~~, I ° Conventional devices " Signal Ctrcwts ~~FFX Data t°°p ~ b 2 " 2nd Floor Il I Convenoonal Hardw ved Indicating Circud it ~ ° . r_ . r_ . r_ r_ . . . . r_ . . . . . . . ~ 1 Par for RS•185 1 Pair for 24 VDC Graphic Annunciator clw AGD-048 modules r.°e.°,.o,. s.w.. s.eo .u. • c,,.n,-,o, w.,. s.m. FX-2009-12 Large Main Chassis in a OAad..>.u. rr.s~w ss.,o wn ©°'°°"°"""°°"' BB-5014 enclosure c/w ECX-0012 Ex ander Chassis RAX•048 IPS•2424 ®~v«,-+e~s"...:..e ^^~^ ~, MsooM s.o p , , , M501M rn'.~Maew FDX•006 and AGD-048. Includes DM-1008 Conventional Indicating Circuit Modules. MsozM ~,.,.o M.~.. External power supply is required for MSOOX r^+'+~~+°1^~• „~OS~ds M5005 ceva wmk incandescent lamps and lamp test. rwnt P ~~~/~`/ ~' a ®~ ~ NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 591 O y page 9 of 10 0 Ordering Information Model Description FX-2000 Standard Series FX-2003-6 Compad Main Chassis dw one Intelligent Analog Loop Contrdler (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Badcait LCO display, 4 Class AB (Style Z!Y) Indcating Cirwits (7.7 Amps each), 16 LED annundation pdMs and a 6 Amp power supply Supports up to 16 Conventional Adder ModtLes. Provides space for 3 Adder Modules. Mounts in the BBX-1024 enclosure. FX-2003-12 Same as above with 12 Amp Power Supply. FX-2017-72A Mid-Size Main Chassis Gw one IMepigent Analog Loop ControOer (99 Analog Sensors end 99 Addressable Modules), 4 x 20 Badc-lit LCD FX-20012 ECX-0012 Expander Chassis for the FX-2009-12 dw space to add up to 12 adder modules and 2 Intemal Annundation modules. Mounts in the BB-5000 FX-2003S-6 Compad Main Chassis c/w 4 x 20 Badc-lit LG) display, 4 Gass AB (Style Z/Y) Indicating Cirwits (1.7 Amps each), 16 LED annundation points and a 6 Amp power supply. Provides space for 3 ALG396S Dual Loop Contrdler Modules. Mounts in the BBX-1024 enclosure. FX-2003572 Same as above with 12 Amp Power Supply. FX-2017512A Mid-S¢e Main Chassis cJw 4 x 20 Badc4it LCD display 4 Gass AIB (Style Z/Y) Indcating Ciraits (7.7 Amps each), 16 LED annunda6on pdMs and a 12 Amp power supply Provides space for 17 Adder ModuleslDual Loop ConUdler Modules and 3 Intemal Annurx9ation modules. Mounts in the BBX-1072A enclosure. FX-2009512 Large Main Chassis dw 4 x 20 Bade-lit LCD display, 4 Gass AB (Style Z11~ Indicating CiraBs (1.7 Amps each), 16 LED annundation pdnts and a 12 Amp power supply Provides space for 9 Adder ModuleslDual Loop Contre~er Modules and 2 Intemal Annundation modules. Mounts in the BB-5000 series enclosures. ECX-0012 Expander Chassis for the FX-2009-12 cJw space to add up to 12 adder modules and 2 Intemal Annundation modules. Mounts in the 86-5000 Adder Loop Controller Modules ALG198S Single Loop Intelligent Analog Loop ConUoOer Module (99 Analog Sensors and 99 Addressable Modules) ALC-3965 Dual Loop Intelligent Analog Loop Contrdler Module (198 Analog Sensors and 198 Addressable Modules) ALC-H16 Hardwire Loop Corttroper Module. Supports 16 Conventional Hardwired Modules. Adder Hardwire Modules DM-1 OOSA Eight Class B (Style B) w 4 Class A (Style D) Initiating Circuit Module SGM-1004A Four Class A/B (Style Z/Y) Indicating Circud Module (Rated at 1.7 Amps per dreuit) RM-1008A Eight Relay Circuit Module dw eight form C relays (Rated for 28 VDC @ 1 Amp max. per relay) Adder Auxiliary Modul es UDACT-300A Digital Alarm Communicator TransmitterlDialer Module PR-300 Polarity Reversal and City Tie Module Programmable Modules RAX-1048 Programmable Zone LED Annundator Module clw 48 bi-coloured LEDs IP52424 Programmable Input Switches Module dw 24 seledw swtches and ~ brodoured LEDs FDX-008 Fan Damper Contrd Module c/w 6 programmabe switches FDX-024 Fan Damper Contrd Module c/w 24 programmable switches Remote Annunciators RAM-1032 Main Annundator Chassis dw Common ConUd Features, Indcators and 32 Bi-Cdoured LEDs RAX-1048 AdderAnnundator Chassis dw 48 Br-Cdoured LEDs RTI-1 Remote Troude Indicator Remote Shared Display Annunciators RAX-LCD Remde Shared Display LCD Annundator dw Display Queues and Common ConVds. Graphic Annunciator Driver Modules MGD•32 Master Graphic Driver Module e/w Fire Alarm Common Contrd Switch Inputs and 32 Supervised Outputs AGD-048 Adder Graphic Driver Module dw 48 Supervised Outputs Enclosures BBX-1024 Black backbox enclosure for FX-2000 dw removable door and CAT-30 kxk and key. Houses one FX-2003-6, FX-2003-12, FX-200356 w FX-2003512 Compad Man Chassis and up to 17 AH batteries. White door. (Add suffix "R" for red door BBX-1072A Blade backbox enclosure for FX-2000 dw removable door and CAT-30 lode and key. Houses one FX-2017-12A or FX-2017512A Mid-Size. Main Chassis, and up to 40 AH batteries. White door. (Add sulfix 'R"tor red door) B&5008 Lobby Contrd Centre Wallbox Enclosure. Supports 8 Module Footprints. DOX-SOOBM White Metal Dow for BB-5008 CCH-5008 Custom Mounting Kit for B&5008. One required per BB-5008. BB-5014 Lobby Contrd Centre Wallbox Enclosure. Supports 14 Module Fodprints. DOX-5014M White Metal Door for BB-5014 CCFI-5014 Custom Mounting Kit for 88-5014. One reglrired per B&5014. FA-UNIV-TRB Universal Blade Semi-Flush Trim Ring for BBX-1024 Badcbox NOT TO BE USED FOR INSTAIIATION PURPOSES. ////i~, COM a MIiZ-_ Distributed by Canada U.S.A. 25 Interchange Way 60 Industrial Parkway Vaughan, Ontario L4K 5W3 Cheektowaga, New York 14227 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http:llwww.mircom.com Email: mail~mircom.com CAT. 59to Iso 9ooi:zooo (;~;~ ___ f Rev.S REGISTERED INTELLIGENT LOW PROFILE SENSORS MIX-200 SERIES Mircom's MIX-200 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. Detector sensitivity is continuously monitored and reported to the FX-2000 Fire Alarm Control Intelligent Low Profile Ionization Smoke Sensor (MIX-1251 B) The Intelligent Ionization Smoke Sensor is constantly monitored to measure any change in its sensitivity due to the environment (dirt, aging, temperature, humidity, etc.) It can give an advance indication to the FX-2000 analog control panel of the need for maintenance and can be specific as to where the maintenance is needed. It can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. f ~~ Intelligent Thermal Sensors (MIX-5251 B/MIX-5251 RB/MIX-5251 H) The Intelligent Thermal Sensors contain a dual thermistor sensing circuit for fast response. They provide open area protection with 50 foot spacing. The sensors rapid response characteristic virtually eliminates the thermal lag which is characteristic of conventional heat detectors and insures operation as soon as the temperature reaches its set point (MIX-5251 B), or upon a temperature rise of 15°F per minute (MIX-5251 RB). The MIX-5251 H provides fixed high temperature detection at 190°F. These sensors can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. Panel. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level. Intelligent Low Profile Photoelectronic Smoke Sensor(MIX-22516) The Intelligent Photoelectronic Smoke Sensor is constantly monitored to measure any change in its sensltivity due to the environment (dirt, aging, temperature, humidity, etc.) It can give an advance indication to the FX-2000 analog control panel of the need for maintenance and can be speck as to where the maintenance is needed. It can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. j ~ '~ ~~~~ .>t Intelligent Low Profile Photoelectronic Smoke Sensor with Thermal (MIX-225176) The MIX-225178 has the same features as the MIX- 2251 B and includes a 135°F thermal sensor. It can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. U~ ~ ~C ~`~~ M EA MSFM approved 2, 5, a roved PP (Mix-,zs,el 2131 56295 56965 7271-1477:122 148-03E (Mlx-2zsleire) (MIX-12518, (MIX-12518. (MIX-f 2518) (MIX-12518) MIX-22518 6 MIX-22518 6 7271-1477:117 219.02-E F M MIX-225176) S6299 (MIX-51518AR8M) MIX-215178) 57498 (MIX.525f8iR8M) (MIX-11518/r8) 7271-1477:114 (MUC-SIS1fl?2BM) (MIX-12518RB) 390-02•E (MIX-52518iRBM) NrxwEo Sa~7996 CATALOG NUMBER 5904 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Specifications Height 2.0 inches (51 mm) C Diameter 6.1 inches (155 mm) Installed in 6210LP Base 4.1 inches (104 mm) Installed in 8501 Base Shipping Weight Heat: 4.8 oz. (137 g) Photo/Photo with Heat: 5.2 oz. (147 g) Ion: 5.4 oz. (154 g) Operating Temperature Range Ion/Photo: 32°F to 120°F (0°C to 49°C) Photo with Thermal: 32°F to 100°F (0°C to 38°C) Thermal: -4°F to 100°F (-20°C to 38°C) High Temperature: -4°F to 100°F (-20°C to 66°C) UL Listed Velocity Range Ion: 0 -1200 fpm (0 - 5.1 m/sec) Photo/Photo with Thermal: 0 - 4000 fpm (0 - 20 m/sec) Relative Humidity 10% - 93% noncondensing Insect Screen Hole Size Photo: 0.016 inch (0.41mm) nominal Ion: 0.035 inch (0.89mm) nominal Thermal Ratings Fixed Temperature Setpoint: 135°F (57°C) Rate of Rise Detection: 15°F/min. (8.3°C/min.) High Temperature: 190°F (88°C) Voltage Range 15 - 32 volts DC peak Standby Current lonlThermal: 150 uA @ 24 VDC (without communication, LED off) 200 uA @ 24 VDC (one communication every 5 sec. with LED enabled) Photo/Photo with Thermal: 250 uA @ 24 VDC (without communication, LED oft? 300 uA @ 24 VDC (one communication every 5 sec. with LED enabled) LED Current (max.) 6.5 mA @ 24 VDC (on) Note: Mounting sensors outside of the specified temperature ranges will cause sensor failures and erratic panel operation. Ordering Information Model Description Intelligent Addressable Analog Sensors MIX-1251 B Intelligent Low Profile Ionization Smoke :,ansor MIX-2251 B Intelligent Low Profile PhotoelectronicSrnoke Sensor MIX-2251T6 Intelligent Low Profile Photoelectronic Smoke Sensor c/w 135°F Fixed Temp. Thermal Sensor MIX-5251 B Intelligent Low Profile Fixed Temp. Thermal Sensor 135°F MIX-5251 RB Intelligent Low Profile Fixed Temp. and Rate of Rise Thermal Sensor 135°F MIX-5251 H Intelligent Low Profile High Temperature Thermal Sensor 190°F Intelligent Analog Bases 6210LP Intelligent Flanged Mounting Base 6224BI Intelligent Isolator Base 6224R6 Intelligent Relay Base' 8501 Intelligent Flangeless Mounting Base 8501 BH Intelligent Sounder Base 6501 BHT Intelligent Temporal Tone Sounder Base Accessories RA-4002 Remote LED Annunciator Note: For Canadian models add suffix A". 'When used with the M500X Fault Isolator Module, the number of relay bases behr~een fault isolators is limited to 12. NOT TO BE USED FOR INSTALLATON PURPOSES. /~~/~`/ // ~' ~~~ r Distributed by: Canada U.S.A. 25 Interchange Way 60 Industrial Parkway Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Cheektowaga, New York 14227 Toll Free: (888) 660-4655 ` Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http:llwww.mircom.com Email: mail~mircom.com CAL 5soa ISO 9007:2000 r;==1 Rev. 5 REGISTERED v INTELLIGENT ADDRESSABLE MANUAL STATIONS MS-700ADU SERIES Description Mircom's MS-700ADU Series provide manual fire reporting. These high quality, die-cast metal Intelligent Fire Alarm Manual Stations are available in either single or dual action configurations with a permanently attached addressable module. The MS-700ADU Series stations are available as single or dual-action devices with key resets and a permanently attached addressable module .The addressable manual station has a pair of rotary decimal switches which allows for two digit address setting. Pulling the handle initiates the operation of the addressable module. All models are available with CAT-30 keys and mount on a standard single gang backbox, Mircom model BB-700 interior surface metal backbox, or BB-700WP weather proof backbox. C7 Features Single or Dual Action Key resettable Permanently Attached Intelligent Addressable Module High-gloss red enamel finish Plastic breakrod Meets ADA 5 Ib. maximum manual-force Mounts on standard single gang box, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox Operation The MS-701ADU Single Action Intelligent Manual Station is operated by pulling down the handle marked "PULL HANDLE" on the front of the station. The MS-710U Dual Action Intelligent Manual Station is operated by pushing the bar labelled "PUSH BAR" and then pulling down the handle marked "PULL HANDLE". The MS-700ADU Series Manual Stations are reset by opening the station with the key, placing the handle in the normal upright position and re- locking the station. Specifications The manual station shall be Mircom's MS-700ADU Series. Operating instructions shall be in raised English lettering and the unit shall be constructed of high quality die-cast metal and finished in red enamel paintto provide quick identification. Pulling the handle shall initiate immediate operation of the intelligent addressable module. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL codes, as well as all other applicable national or local codes. Final acceptance is subject to the local authority having jurisdiction. l7 L kvL S7005 57005 ~15a1a7r1zs CATALOG NUMBER 5928 Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. MS-701 ADU MS-710ADU Intelligent Addressable Intelligent Addressable Single Action Manual Station Dual Action Manual Station Specifications Switch Rating: Manual Station Dimensions: Color: Current Consumption: Surface Mount Backboxes 1 Amp @ 30 VDC 0.1 Amp @ 125 VAC 4.9" H x 3.5" W x 2.0" D Red with raised white letters, white Manual bar with raised red letters. Standby: 400 uA Alarm: 5.5 mA BB-700 Surface Mount Backbox Dimensions: 5° H x 3.6" W x 2.0" D Typical Wiring Diagram BB-700WP Weatherproof Surtace Mount Backbox Dimensions: 5" H x 3.6" W x 2.2" D MS-701ADU and MS-710ADU FROM r ~ Reo PREVIOUS ( TO NEXT STATION OR } eLK STATION ` %'~f Y END OF LINE DEVICE BLACK eu< g 4 ADDRESSABLE MODULE + RED ~ NOTES: 1. WIRE AS SHOWN SO THAT SUPERVISION PuR o ~ OF CONNECTIONS IS MAINTAINED. yE~ y ~ 2. MOUNT STATION TO 4' SQUARE x 1 112' DEEP ~ OUTLET BOX WITH PLASTER RING RAISED 112". ~--' YELLOW 3. SWRCH RATING: ALL MODELS to aQ 30VDC, 0.1A (c~ 125VAC N.O. 4. MAXIMUM WIRE SIZE: No. 12 AWG. SWITCH 5. REFER TO FIRE ALARM CONTROL PANEL MANUAL FOR ADDRESSABLE MODULE SETTING. Ordering Information Model Description MS-701ADU Intelligent Addressable Key Resettable Single Action Manual Station MS-702ADU Intelligent Addressable Key Resettable Dual Stage Single Action Manual Station MS-710ADU Intelligent Addressable Key Resettable Dual Action Manual Station BB-700 Series 700 Interior Surface Mount Backbox, Red Finish BB-700WP Series 700 Weatherproof Surface Mount Backbox, Red Finish Add suffix "NY" for New York Versions NOT TO BE USED FOR INSTALLATION PURPOSES. !/~~/!/ // ~'i /~/~~,,. •V^ Distributed by: Canada U.S.A. 25 Interchange Way 60 Industrial Parkway Vaughan, Ontario L4K 5W3 Cheektowaga, New York 14227 Telephone: (905) 6603655 Toll Free: (888) 660655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http:/ANww.mircom.com Email: mail~mircom.com CAT. 5928 ISO 9001:2000 Rrr. 2 ~ REGISTERED Series ZRS Strobes, ZNS Horn Strobes and Series ZNH Horns SNAP'S The EZ Mount Series ZNS Series ZNH ~(1' •, ,_ :. ~. sM- .;~- :J Series ZRS Series ZRS Description The Wheelock Series Z notification appliances feature an easy snap on base that is designed to simplify the installation and testing of horns, strobes, and horn/strobes. The separate Series Z snap on base can be pre-wired so circuit wiring can be fully tested before the appliance is installed and before the walls are covered. Once all surrounding work is complete, the appliance can be simply installed by snaping it on the base. Shorting contacts in the base, which provide continuity for circuit testing, are permanently opened when the appliance is installed so any subsequent removal of the appliance will indicate a trouble condition on that circuit at the control panel when circuit supervision is enabled. The same base is used for all Series Z horns, strobes and horn/strobes to provide consistent installation and easy replacement of appliances if required. A locking screw is also included for the appliance to provide extra secure installation. The Wheelock Series Z appliances incorporate the same dependable circuitry and high efficiency optics that are used in Wheelock RSS strobes, NS horn/strobes and NH horns and have the same high performance ratings. The Series Z appliances are compatible with all UL listed "Regulated" panels and all panels that are compatibility listed with Wheelock RSS, NS and NH appliances. Features Approvals include: UL Standard 1971, UL Standard 464, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP). See approvals by model number in Specifications and Ordering Information ADA/NFPA/UFC/ANSI and OSHA 29, Part 1910, 165 compliant EZ Mount SNAP design, with separate base plate, provides ability to pre-wire the base and test the circuit wiring before the walls are covered The base plate is protected by a disposable cover and the appliances can quickly snap onto the base after the walls are painted. Patented EZ Mount Universal Mounting Plate -uses single plate for ceiling and wall mount installations Wall Mount models feature field selectable candela settings of 15/30/75/110cd and 135/185cd Ceiling Mount models feature field selectable candela settings of 15/30/75/95cd and 115/177cd Strobes can be synchronized using the Wheelock sync modules or power supplies with built-in sync protocol 2 and 24 VDC models with UL "Regulated Voltage" using filtered DC or unfiltered VRMS input voltage Strobes produce 1 flash per second over the "Regulated Voltage" range (ZNS, ZRS models) Selectable Continuous Horn or Temporal (Code-3) Tones with selectable 90 or 95 dBA setting (ZNH, ZNS models) Selectable 12 or 24VDC in 1 appliance (ZNH model) CATALOGUE NUMBER 5262 NOT TO BE USED FOR INSTALLATION PURPOSES. :ircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. NOTE: All CAUTIONS and WARNINGS are identified by the symbolA. All warnings are printed In bold capital letters. © WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT YVWW.000PERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. 0 General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series ZNS Strobe products are listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (t 2%). • Series ZNH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Series ZNS Ratings Per UL Standard 1971 Table 2: Series ZNS/ZNH Horn dBA Ratings Model Input Voltage VDC Regulated Voltage Ran a VDCIFWR Strobe Candela CD ( ) Description Volume Reverberant dBA @ 10ft er UL 464 p 12 24 VDC VDC Anechoic dBA 10 ft e° 12 24 VDC VDC ZNS-MCW 24 16.0 - 33.0 15/30/75/110 Continuous High 83 87 89 95 ZNS-MCWH 24 16.0 - 33.0 135/185 Horn Low 76 81 84 90 ZNS-MCC 24 16.0 - 33.0 15/30/75/95 Code 3 High 79 82 89 95 ZNS-MCCH 24 16.0 - 33.0 115/177 Horn Low 72 76 84 90 able 3: Series ZNS Average RMS Current* Audible Wall Mount Strobe Models Ceiling Mount Strobe Models Series ZNS/ZNH 24 VDC ZNH-12/24 ZNS-MCW ZNS-MCWH ZNS-MCC ZNS-MCCH @24VDC 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd High (95) dBA 24VDC 0.044 0.074 0.107 0.184 0.244 0.350 0.477 0.082 0.124 0.209 0.275 0.350 0.477 ow (90) dBA 24VDC 0.018 0.066 0.101 0.177 0.232 0.306 0.429 0.071 0.114 0.201 0.261 0.306 0.429 Audible Series ZNSIZNH 12VDC ZNH-12124 ~I @12V High (89) dBA 12 VDC 0.021 ' ow (84) dBA 12VDC 0.012 Table 4: Series ZRS Average RMS Current* ZRS -Wall Mount ZRS -Ceiling Mount ZRS 24VDC Models MCW MCWH MCC MCCH 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24 vdc 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 ' RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. M~RCOM f' CAT. 5262 //~~~~, ~~~v„~ NOT TO BE USED FOR INSTALLATION PURPOSES. page 2 Of 4 e Wiring Diagrams# ZNS2NH APPLIANCE + + TO NEXT FROM _ APPLIANCE PRECEDING OR EOLR APPLIANCE, SM/DSM, PS-24-SMC OR FACP + - SIGNAL ULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILEN FEATURE SM F ~ STROBE - STROBE A Strobe NAC Circuit NS NH C (Audible P EOLR Audible -Audble NAC NOTE: ZNS2NH must be set on Code3 hom tone to achieve synchronized temporal (Code3) tone. Refer to Installation Instruction (P83983, P83600 respectively). ' For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84662 for PS-24-8MC. :] Model Number Order Strobe Sync w/ SM, DSM or 24 12 Mounting Agency Approvals - Code Candela pS-24-8MC VDC VDC Options# UL MEA CSFM FM BFP ZNS-h1CW-FR 0304 15/30/75/110 X X - B, D, E, F X X • ZNS-h1CW-FW 0305 15/30/75/110 X X - B, D, E, F X X ZNS-MCWH-FR 0306 1351185 X X - B, D, E, F X X ' ZNS-h1CWH-FW 0307 135/185 X X - B, D, E, F X X ' ZNH-R 0300 - X X X B, D, E, F X ' X ZNH-VY 0301 - X X X B, D, E, F X X ' ZNS-MCC-FR 0310 15/30/75/95 X X - B, D, E, F X ' X ZNS-h1CC-FW 0311 15/30/75/95 X X - B, D, E, F X X ' ZNS-MCCH-FR 0312 115/177 X X - B, D, E„F X X ZNS-h1CCH-FW 0313 115/177 X X - B, D, E, F X X ' ZRS-h1CW-FR 4085 15/30/75/110 X X - B, D, E, F X X ' ZRS-MCW-FW 0302 15/30/75/110 X X - B, D, E, F X X ZRS-h1CWH-FR 5242 135/185 X X - B, D, E, F X X ' ZRS-MCWH-FW 0303 135/185 X X - B, D, E, F X X ' ZRS-h1CC-FW 0309 15/30/75/95 X X - B, D, E, F X X ' ZRS-MCC-FR 0308 15/30175/95 X X - B, D, E, F X • X ZRS-MCCH-FR 5240 115/177 X X - B, D, E, F X X ZRS-MCCH-FW 0314 115/177 X X - B, D, E, F X X • 'Pending #The ZRS, ZNS and ZNH will mount to single-gang, double-gang, 4" octal, 4" square and 3-1/2" octal back boxes. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. r CAT. 5262 ~~~~~~, M ~ R COM NOT TO BE USED FOR INSTALU4TION PURPOSES. page 3 d 4 Specifications and Ordering Information Architects and Engineers Specifications General AudibleNisual notification appliances shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. These appliances shall be listed under UL Standard 1971, (Standard for Safety Signaling Devices for Hearing Impaired) and UL Standard 464 (Fire Protective Signaling). The appliances shall use a Patented Universal EZMount backplate that shall allow mounting to a single-gang, double-gang, 4-inch square, 4° octal, or a 3-1/2" octal backbox. Two wire appliance wiring shall be capable of directly connecting to the mounting back plate. Continuity checking of the entire NAC circuit prior to attaching any audible/visual notification appliances shall be allowed. A dust cover shall fit and protect the mounting plate. The dust cover shall be easily removed when the appliance is installed over the backplate. Removal of an appliance shall result in an alarm condition by the Fire Alarm Control Panel (FACP). Strobes Strobe appliances shall produce a minimum flash rate of 60 flashes per minute (1 flash per second) over the Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube enclosed in a rugged l_exan lens. The strobes shall be available with two or four field selectable settings in one unit and shall be rated, per UL 1971, for up to 185 cd for wall mounting and 177 cd for ceiling mounting. The strobes shall op- erate over an extended temperature range of 32°F to 120°F (0°C to 49°C) and be listed for maximum humid- ity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Audibles and Audible/Strobe Combinations Horns and horn/strobes shall be listed for Indoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 2 sound level settings of 90 and 95 dBA. Synchronization Modules When synchronization of strobes or temporal Code-3 audibles is required, the appliances shall be compat- ible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-24-8MC Power Supply with built-in, patented sync protocol. The strobes shall not drift out of synchronization at any time during operation. Audibles and strobes shall be able to be ~vnchronized on a 2-wire circuit with the capability to silence the au- dible if required. If the sync module or power supply fails to operate (i.e., contacts remain closed), the strobes shall revert to anon-synchronized flashrate. NOT TO BE USED FOR INSTALLATION PURPOSES. //~///<<, MIRCOM` Canada U.S.A. 25 Interchange Way 60 Industrial Parkway Vaughan, Ontario L4K 5W3 Cheektowaga, New York 14227 Telephone: (905) 660-4655 Toll Free: (888) 660655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com '~~SO 9007:2000 /:~:~ RCVI~ 1 CRC~J \~~~/ WEATHERPROOF STROBES/AUDIBLE STROBES MT/RSS/AH/AS SERIES Features Series ASWP Series AHWP Series MTWP Description Tt~;; Weatherproof Strobe,Audible Strobe, Audible Hom and Multitone Strobe appliances have an extended temperature range of-31 °F to 150°F (-35°C to 66°C) that will satisfy virtually all outdoor and severe environment applications. All strobes are Indoor/Outdoor UL Standard 1638 Listed and rated for 180 candela on axis @ 78°F (25°C) and 75 candela at -31°F (-35°C) with low current draw. These Weatherproof Appliances are designed for maximum performance, reliability, and cost effectiveness while meeting or exceeding the latest requirements of NFPA 72 (National Fire Alarm Code), UL Standard 1638 (Standard for Vsual Signaling Appliances), and UL Standard 464 (Standard for Audible Signaling Appliances). Weatherproof Strobe Series RSSWP is UL Standard 1638 approved for Indoor/Outdoor use. The appliances use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan®lens to provide maximum visibility and reliability for effective visual signaling. The Series RSSWP mounts to a Series WPSBB Weatherproof Backbox. Approvals include: UL Standard 1971, California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP) Designed to meetorexceed NFPA,/UFC/ANSI 117.1! OSHA Part 29, 1910.165, and ADA requirements UL Standard 1638 and UL Standard 464 listed with extended temperature range of-31° to 150°F (-35°C to 66°C) 24 VDC with new UL "Regulated" Voltage Range of 16-33 VDC using filtered DC or unfiltered FWR voltage Selectable dBA settings Selectable alert signals IN and OUT wiring termination that accepts two #12-18AWG wires at each terminal Inputs are polarized for compatibility with industry standard reverse polarity supervision Weatherproof Audible Strobe and Audible Series ASWP is UL Standard 1638 and UL Standard 464 approved for Indoor/Outdoor use and offers a field selectable choice of continuous horn or temporal pattern (Code 3) when constant voltage from the Fire Alarm Control Panel (FACP) is applied. Additionally, the audible has three (3) selectable dBA settings of 99, 95, and 90 dBA in both tones. The Series ASWP mounts to a WPBB Weatherproof Backbox. Weatherproof Multitone Strobe and Multitone Horn Series MTWP are UL Standard 1638 and UL Standard 464 approved for Indoor/Outdoor use and offer a field selectable choice of 8 nationally and internationally recognized alerting signals. Additionally, the audible has 2 installer selectable sound output levels: Standard and high covering a range (depending on selected signal) of 76-94 dBA reverberant. The Series MTWP is a true 4 wire appliance. The Series MTWP mounts to a series 106 Backbox. ~L U ~C '~~~ M EA ~ v approved CATALOG NUMBER 5253 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Engineering Specifications The Weatherproof Strobe appliances shall be Series RSSWP-2475W strobes or approved equals. The Series RSSWP shall meet and be listed for UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use. The strobe appliances shall produce a flash rate of 30-62 flashes per minute over the Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube enclosed in a rugged Lexan~ lens. The strobe shall be rated at 75cd and shall operate over an extended temperature range of -31 °F to 150°F (-35°C to 66°C). All inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel. The Series RSSWP shall be mounted only to the WPSBB-R Backbox. The WeatherproofAudibleSfrobe and Audible appliances shall be SeriesASWP-2475WAudible Strobes or approved equals. The Series ASWP shall meet and be listed for UL Standard 1638 (Standard for usual Signaling Appliances) for Indoor/Outdoor use. The strobe appliances shall produce a flash rate of 30-62 flashes per minute over the Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube enclosed in a rugged Lexan'~ lens. The strobe shall be rated 180cd @ 77°F (25°C) and 75cd at -31 °F (-35°C) and shall operate over an extended temperature range at -31 °F to 150°F (-35°C to 66°C) and be listed for maximum humidity at 95% RH. All inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The Series ASWP shall be mounted only to the WPBB-R Backbox. The weatherproof audible strobe appliances shall be designed for two-wire operation and shall provide either a continuous or temporal (Code 3) tone when constant voltage from a Notification Appliance Circuit (NAC) of the Fire Alarm Control Panel (FACP) is applied. They shall be designed so that the audible signal may be silenced while maintaining strobe activation. The Weatherproof Multitone Strobe and Multitone Audible appliances shall be a Series MTWP or equivalent. The Series MTWP shall meet and be listed for UL Standard 1638 (Standard for ~lsual Signaling Appliances) for indoor/ outdoor use. The strobe portion of the appliance shall produce a flash rate of 30-62 flashes per minute over the listed voltage range of 20-31 VDC and shall incorporate a Xenon flash tube enclosed in a rugged Lexan®lens. The strobe shall be rated 180cd @ 77°F (25°C) and 75cd at -31 °F (-35°C) and shall operate over an extended temperature range at -31 °F to 150°F (-35°C to 66°C) and be listed for maximum humidity at 95% RH. All inputs shall be polarized for compatibility with industry standard reverse polarity of circuit wiring by a Fire Alarm Control Panel. The audible portion of the Series MTWP shall provide eight field selectable alarm signals. The signals shall consists of: Hom, Bell, March Time, Code 3 Hom, Code 3 Tone, Slow Whoop, Siren and Hi/Lo. Tone selection shall be by a durable dip switch assembly. Clips or Jumpers are not acceptable. The appliance shall provide two output sound levels: Standard and High dBA. The range of c1BA shall be 75 to 94 dBA. The Series MTWP shall have an operating voltage of 24 VDC (nominal). Both models shall have provisions for In/Out field wiring using terminals that accept #12 to #18 AWG wiring. The Series MTWP shall be mounted only to the IOB-R Backbox. Ordering Information Model Number Strobe cd @ -31°F (-35°C) Strobe cd @ 77°F (25°C) dBA Input Voltage Color Strobe RSSWP-2475W-FR 75cd 180cd - 24 VDC Red Audible Strobe ASWP-2475W-FR 75cd 1480cd 90, 95, 99 24 VDC Red Horns/Audibles AH-24VdP-R N/A N/A 90, 95, 99 24 VDC Red AH-12WP-R 90, 95, 99 24 VDC Red Multitone Strobe MTWP-2475W-FR 75cd 180cd 76-94 24 VDC NOT TO BE USED FOR INSTALLATION PURPOSES. /1~~/<<, MIRC~~ M Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 60 Industrial Parkway Cheektowaga, New York 14227 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Web page: http:IPowaw.mircom.wm Email: mail~mircom.wm REGISTERED ~~~ Rev.1 Series MB Motor Bells RSSP REMOTE PLATE Description The Wheelock Series MB Motor Bells provide a better engineered motor bell for fire and life safety alarm systems. The Wheelock Series MB Bells include higherdBA, low current draw, built-in trimplate for semi-flush mounting, low frequency aluminum shells, and low RFI noise. The motor for Series MB Bells is a durable, high torque permanent magnet motor selected for its high performance and long life. These DC vibrating Series MB Motor Bells are offered in 6" and 10" shell sizes in both 12 and 24 VDC models. Series RSSP Sync/Non-Sync retrofit plates are used in conjunction with the Series MB Motor Bell when combination appliances are required. The Series RSSP retrofit plates are available with either Multi-Candela or single candela strobes and easily mount to a 4" square or Wheelock SBL-2 backbox. All Series RSSP strobe appliances meet or exceed the requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard forAccessible and Usable Buildings and Facilities), ADA (Americans with DisabilitiesAct) and UL Standard 1971 (Signaling Devices for the Hearing Impaired). The Series RSSP retrofit plates may be synchronized when installed with the Wheelock Series SM, DSM, Sync Modules orthe PS-24-8MC Power Supply with Wheelock patented sync protocol. Wheelock synchronized strobes offer an easy way to comply with ADA requirements concerning photo-sensitive epilepsy. Ordering Information Features • Approvals include: UL Standard 464, Factory Mutual (FM), Califor nia State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP) • Meets OSHA 29 Part 1910.165 High sound output with low current draw Low frequency aluminum shells for better audibility through walls, doors and other structures 6" and 10" shell sizes in 12 or 24 VDC models Integral RFI suppression to minimize included noise on the NAC circuit Mounting options for surface, semi-flush, outdoor, and concealed conduit installation Built-in trimplate makes semi-flush mounting simpler and less expensive Screw terminals permit fast in-out field wiring of #12 to 18 AWG wire Polarized for DC supervision of NAC circuits Operates on filtered or unfiltered DC For combined audible (bell) and visual signaling, convenient retrofit plate assemblies are available with Multi-Candela or Single candela strobes (Refer to Fire Alarm Products Catalog for Series RSSP Sync/Non-Sync Strobes specifications and technical information) NOTES: 1. Typical dBA at 10 feet is measured in an anechoic chamber. 2. For bells all 12 VDC models are UL rated for 9.0 to 15.6 VDC and all 24 VDC models for 18.0 to 31.0 VDC. Model Number Order Code Shell Size Input Voltage (VDC) Average RMS Current UL Max* dBA @ 10 Ft. Mounting Options MB-G6-12-R 3942 6" 12 0.060 0.090 MB-G6-12-S 4221 6" 12 0.060 0.090 MB-G6-24-R 3941 6" 24 0.030 0.040 MB-G6-24-S 4222 6° 24 0.030 0.040 MB-G10-12-R 3944 10" 12 0.060 0.090 92 D,E,J,K,N,O,P,R,S MB-G10-12-S 4223 10" 12 0.060 0.090 MB-G10-24-R 3943 10" 24 0.030 0.040 MB-G10-24-S 4224 10° 24 0.030 0.040 - , ne<m _%a ~''• ~"~' FM UL °,~); ® IVI EA APPROVED E5946 151-92-E 71350785:113 • RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. COOPER Notification Architects The alarm appliances shall be Wheelock Series MB vibrating Motor Bells or approved equal. They shall be UL Standard 464 Listed for Fire Protective Service. Shells shall be aluminum in 6" or 10" diameter. Sound output at 10 feet shall be 92 dBA. The bells shall incorporate a permanent magnet motor and suppression circuitry to minimize RFI. They shall include abuilt-in trimplate for semi-flush mounting to a standard 4° square backbox, or surface mounting to Wheelock's indoor BB backbox or outdoor WBB backbox. r bell strobe applications, retrofit plates Wheelock Series RSSP with Multi-Candela or Single Candela strobes shall be used. All bell models shall be polarized for line supervision and shall have screw terminals for in-out field wiring of #12 to #18 AWG wire. Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be textured enamel. Model Number Order Code Nominal Voltage (VDC) Strobe Candela Average Current (AMPS) at listed VDC UL Max* "'Mounting Options RSSP-24MCW FR 9402 24 15/30/75/110 .041/.063/.109/.140 .060/.092/.165/.220 D,E,Z RSSP-241575W FR 7793 24 15 (75 on-axis) .060 .090 D,E,Z RSSP-121575W-FR 7798 12 15 (75 on-axis) .152 .255 D,E,Z RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). Wiring For unfiltered FWR ratings, see installation instructions. Fig. 1 Bell Models -~^ FRDMO TO NE%TO PRECEDING? ff APPLIANCED APPLIANCE) l }~ END-OF-LIr OR FAC FJ RESISTDRO (EDLR)0 Fig. 2 Retrofit Strobe Plate Models AUDIBLEO STRDBEO ~+a-~ +a J FFsQ PkE_E'vlNYJ T NE`1C1 PFFL: N:,S :4a rTtiFa ~ LIFw'fC ~ ` E:ava iFUG " PFE.Y IN~.a T IIE: Ti 3TE.EC JFa 1 ~n¢ GFa F>: FCI T ~ Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Assodation (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes inducting, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Q WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In accordance with Wheelock Inc. standard terms and conditions. /~~~~'1 JAI I!~ WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY 51500 MB 02/08 ~[~ Cooper Notification is WheelOCk' MmC $AFEPATH' wnvi~ ~' i'"a COOPERNotification