05-0770 Water Review No. 2 121407 From: Deonne Hardy
Sent: Friday, December 14, 2007 2:56 PM
To: Tim Peterson
Cc: deonneh@ci.yelm.wa.us; Kevin Ray; Steve Harrington; Jim Gibson
Subject: Samantha Ridge, Review #2
Attachments: image003.wmz; oledata.mso
Water review for Samantha Ridge
????r
City of
Yelm Public Works Department
901 Rhoton Road
P.O. Box
479
Yelm
, WA 98597
(360) 458-8406 Fax: (360) 458-8417
Public Works Inspection Report
Date: 14 December 20007 Page 1 of
Location:
Samantha Ridge Department: Water
Contractor Rep:
This property has a Reclaimed Water main running through it. All of the water meter will need a Reduced Pressure Backflow Assembly behind them.
At station 2 + 17.39- the sewer is too close to the water main.
From station 0 + 54.45, need to run the new water main straight to the existing main under Crystal Spring Road and hot tap the old water main. Will need to cut and cap or
plug the old main at the gate valve under Crystal Springs Road.
The valves shown on the one inch service lines should be Corp Stops not gate valves.
The irrigation shows the backflow assembly before the water meter, this needs to be behind the meter.
This property has Reclaimed Water going through the project; can this be used for the irrigation system?
Reviewed by: John I, Tim R and Edward Smith
Signed by Edward Smith