T T Fairway Multi-Family Housing Plan Review Public Works docIPM.Note
T T Fairway Multi-Family Housing Plan Review Public Works.doc
Steve Harrington
Edward Smith
Steve Harrington
EX
/O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=SMITTY
T T Fairway Multi-Family Housing Plan Review Public Works.doc
EX
/O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=STEVEH
EX
/O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=STEVEH
Edward Smith
EX
/O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=SMITTY
Deonne Hardy; Kevin Ray; Jim Gibson; Steve Harrington
Tim Peterson
T T Fairway Multi-Family Housing Plan Review Public Works.doc
00000002SERVER1/o=CITYOFYELM/ou=first administrative group/cn=Recipients/cn=smittyMicrosoft Exchange Server
00000002SERVER1/o=CITYOFYELM/ou=first administrative group/cn=Recipients/cn=smittyMicrosoft Exchange Server
Plan review for TT Fairway Multi-Familt Housing from water department.
_____
City of Yelm
Public Works Department
901 Rhoton Road
P.O. Box 479
Yelm, WA 98597
(360) 458-8406 Fax: (360) 458-8417
Public Works Inspection Report
Date: 3-Dec-2007 Page 1
Location: TT Fairway Multi-Family Housing Department: Water
Contractor: Rep:
1. The developer is responsible for the cost of the fire hydrant locks and the City of Yelm Water Department will order and install them. The project will not be final until
the City of Yelm has received the payment in full for the fire hydrant locks.
2. Eliminate the existing ten main to the blow off at the end, and at station 0 + 70.28 install a gate valve and 22 1/2 bend.
3. Deflect the main from station 0 + 70.28 to station 2 + 44.19 too eliminating the bends.
4. At station 4 + 06.50, the Tee must be an ten by ten by eight inch Tee, with eight inch gate valve and pipe to the fire hydrant.
5. The Tee at fire hydrant at station 4 + 06.54 must be eight by eight by six inch Tee.
6. All of the fire hydrant runs must be eight inch pipe with eight by eight by six inch Tees at the fire hydrants.
7. The irrigation meter will need a Double Check Valve Assembly behind the water meter setter.
8. At stations 6 + 54.09 and 5 + 29 .37 need to have two inch gate valves on the Tees.
9. The thrust block at station 18 + 50.44 need to be a ecology block, so the water may be turned back on after the connection is done.
10. The connection to the existing main on sheet 14 - drawing C6.3 is a ten inch main.
Reviewed by: Edward Smith, John I
Signed by: Edward Smith
<DC90029353CCCD468AA2A2858FFCD8F5051423@server1.ci.yelm.wa.us>
T T Fairway Multi-Family Housing Plan Review Public Works.doc.EML
Edward Smith
Edward Smith
11.0
Microsoft Exchange Server
00000002SERVER1/o=CITYOFYELM/ou=first administrative group/cn=Recipients/cn=smitty
Tim Peterson
EX
/O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Tim
tim@ci.yelm.wa.us
tim
458-8499
Public Works
Tim Peterson
Tim Peterson
tim
Deonne Hardy
EX
/O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Deonne
deonne@ci.yelm.wa.us
deonne
Public Works
Deonne Hardy
Deonne Hardy
deonne
Kevin Ray
EX
/O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Kevin
kevin@ci.yelm.wa.us
kevin
458-8412
Public Works
Kevin Ray
Kevin Ray
kevin
Jim Gibson
Jim Gibson
EX
/O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Gibson
jimg@ci.yelm.wa.us
jimg
Jim Gibson
Jim Gibson (jimg@ci.yelm.wa.us)
jimg@ci.yelm.wa.us
Steve Harrington
EX
/O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Steveh
steveh@ci.yelm.wa.us
steveh
458-8423
Community Development
Steve Harrington
Steve Harrington
steveh
image001.gif
.gif
image001.gif
image001.gif
image/gif
image001.gif@01C8359B.3906D050
image002.gif
.gif
image002.gif
image002.gif
image/gif
image002.gif@01C8359B.3906D050
image003.gif
.gif
image003.gif
image003.gif
image/gif
image003.gif@01C8359B.3906D050