Loading...
T T Fairway Multi-Family Housing Plan Review Public Works docIPM.Note T T Fairway Multi-Family Housing Plan Review Public Works.doc Steve Harrington Edward Smith Steve Harrington EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=SMITTY T T Fairway Multi-Family Housing Plan Review Public Works.doc EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=STEVEH EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=STEVEH Edward Smith EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=SMITTY Deonne Hardy; Kevin Ray; Jim Gibson; Steve Harrington Tim Peterson T T Fairway Multi-Family Housing Plan Review Public Works.doc 00000002SERVER1/o=CITYOFYELM/ou=first administrative group/cn=Recipients/cn=smittyMicrosoft Exchange Server 00000002SERVER1/o=CITYOFYELM/ou=first administrative group/cn=Recipients/cn=smittyMicrosoft Exchange Server Plan review for TT Fairway Multi-Familt Housing from water department. _____ City of Yelm Public Works Department 901 Rhoton Road P.O. Box 479 Yelm, WA 98597 (360) 458-8406 Fax: (360) 458-8417 Public Works Inspection Report Date: 3-Dec-2007 Page 1 Location: TT Fairway Multi-Family Housing Department: Water Contractor: Rep: 1. The developer is responsible for the cost of the fire hydrant locks and the City of Yelm Water Department will order and install them. The project will not be final until the City of Yelm has received the payment in full for the fire hydrant locks. 2. Eliminate the existing ten main to the blow off at the end, and at station 0 + 70.28 install a gate valve and 22 1/2 bend. 3. Deflect the main from station 0 + 70.28 to station 2 + 44.19 too eliminating the bends. 4. At station 4 + 06.50, the Tee must be an ten by ten by eight inch Tee, with eight inch gate valve and pipe to the fire hydrant. 5. The Tee at fire hydrant at station 4 + 06.54 must be eight by eight by six inch Tee. 6. All of the fire hydrant runs must be eight inch pipe with eight by eight by six inch Tees at the fire hydrants. 7. The irrigation meter will need a Double Check Valve Assembly behind the water meter setter. 8. At stations 6 + 54.09 and 5 + 29 .37 need to have two inch gate valves on the Tees. 9. The thrust block at station 18 + 50.44 need to be a ecology block, so the water may be turned back on after the connection is done. 10. The connection to the existing main on sheet 14 - drawing C6.3 is a ten inch main. Reviewed by: Edward Smith, John I Signed by: Edward Smith <DC90029353CCCD468AA2A2858FFCD8F5051423@server1.ci.yelm.wa.us> T T Fairway Multi-Family Housing Plan Review Public Works.doc.EML Edward Smith Edward Smith 11.0 Microsoft Exchange Server 00000002SERVER1/o=CITYOFYELM/ou=first administrative group/cn=Recipients/cn=smitty Tim Peterson EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Tim tim@ci.yelm.wa.us tim 458-8499 Public Works Tim Peterson Tim Peterson tim Deonne Hardy EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Deonne deonne@ci.yelm.wa.us deonne Public Works Deonne Hardy Deonne Hardy deonne Kevin Ray EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Kevin kevin@ci.yelm.wa.us kevin 458-8412 Public Works Kevin Ray Kevin Ray kevin Jim Gibson Jim Gibson EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Gibson jimg@ci.yelm.wa.us jimg Jim Gibson Jim Gibson (jimg@ci.yelm.wa.us) jimg@ci.yelm.wa.us Steve Harrington EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Steveh steveh@ci.yelm.wa.us steveh 458-8423 Community Development Steve Harrington Steve Harrington steveh image001.gif .gif image001.gif image001.gif image/gif image001.gif@01C8359B.3906D050 image002.gif .gif image002.gif image002.gif image/gif image002.gif@01C8359B.3906D050 image003.gif .gif image003.gif image003.gif image/gif image003.gif@01C8359B.3906D050