Loading...
Steve FW Comments for Tahoma Terra Fairway Multi-Family Review # 2IPM.Note Steve FW: Comments for Tahoma Terra Fairway Multi-Family Review # 2 Roberta Allen Steve Harrington Roberta Allen EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=STEVEH Comments for Tahoma Terra Fairway Multi-Family Review # 2 EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_ALLEN EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_ALLEN Steve Harrington EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=STEVEH Roberta Allen Steve FW: Comments for Tahoma Terra Fairway Multi-Family Review # 2 Roberta: Here are the comments for Tahoma Terra Fairway Multi-Family Review # 2. I sent them to Jim on 12/06/07, it was my understanding he requested them from me? You will find them below on this e-mail to Jim. Thank you, Steve ________________________________ From: Steve Harrington Sent: Thursday, December 06, 2007 4:22 PM To: Jim Gibson Subject: Comments for Tahoma Terra Fairway Multi-Family Review # 2 Jim: The following are review comments for the Tahoma Terra Fairway Multi-Family Review # 2. 1. Item # 2 from the 1st review still needs to be addressed. This section discusses the pervious area only, does not cover the treatment or infiltration. 2. Item # 7 from the 1st review still needs to be addressed for treatment and infiltration. 3. Item # 8 from the 1st review still needs to be addressed and show, concerning storage volume. 4. Detail on sheet C4.2 (5) Trail Detail callouts are cut off. 5. Item # 30 from the 1st review, the given elevations, appear to have storm run off running up into the interceptor swale? 6. Item # 32 from the 1st review has the roof drains running into the parking lot. Is this typical for all buildings? 7. Should the irrigation meter on the domestic water line have a back flow prevention device on it, after the meter? 8. Item # 50 from the 1st review still needs to be addressed. 9. All cleanouts on the side sewers, need to be shown on plans. Thank you, Steve Harrington Engineering / Civil Inspector City of Yelm Office (360) 458-8423 / Field (360) 561-4264 <DC90029353CCCD468AA2A2858FFCD8F54F412B@server1.ci.yelm.wa.us> Steve FW%3A Comments for Tahoma Terra Fairway Multi-Family Review %23 2.EML Steve Harrington Roberta Allen 11.0 Roberta Allen EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_allen r_allen@ci.yelm.wa.us r_allen 458-3835 Community Development Roberta Allen Roberta Allen r_allen