Loading...
Water FW T T Fairway Multi-Family Housing Plan Review Public Works docIPM.Note Water FW: T T Fairway Multi-Family Housing Plan Review Public Works.doc Roberta Allen Jim Gibson Roberta Allen EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=GIBSON T T Fairway Multi-Family Housing Plan Review Public Works.doc EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_ALLEN EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_ALLEN Jim Gibson EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=GIBSON Edward Smith Roberta Allen Water FW: T T Fairway Multi-Family Housing Plan Review Public Works.doc Roberta here is the email from smitty for Fairway Estates Jim Gibson P.E. City of Yelm, Development Review Engineer PO Box 479 Yelm,WA. 98597 Ph. 360.458.8438 Fx. 360.458.3144 jimg@ci.yelm.wa.us ________________________________ From: Edward Smith Sent: Monday, December 03, 2007 10:57 AM To: Tim Peterson Cc: Deonne Hardy; Kevin Ray; Jim Gibson; Steve Harrington Subject: T T Fairway Multi-Family Housing Plan Review Public Works.doc Plan review for TT Fairway Multi-Familt Housing from water department. ________________________________ City of Yelm Public Works Department 901 Rhoton Road P.O. Box 479 Yelm, WA 98597 (360) 458-8406 Fax: (360) 458-8417 Public Works Inspection Report Date: 3-Dec-2007 Page 1 Location: TT Fairway Multi-Family Housing Department: Water Contractor: Rep: 1. The developer is responsible for the cost of the fire hydrant locks and the City of Yelm Water Department will order and install them. The project will not be final until the City of Yelm has received the payment in full for the fire hydrant locks. 2. Eliminate the existing ten main to the blow off at the end, and at station 0 + 70.28 install a gate valve and 22 1/2 bend. 3. Deflect the main from station 0 + 70.28 to station 2 + 44.19 too eliminating the bends. 4. At station 4 + 06.50, the Tee must be an ten by ten by eight inch Tee, with eight inch gate valve and pipe to the fire hydrant. 5. The Tee at fire hydrant at station 4 + 06.54 must be eight by eight by six inch Tee. 6. All of the fire hydrant runs must be eight inch pipe with eight by eight by six inch Tees at the fire hydrants. 7. The irrigation meter will need a Double Check Valve Assembly behind the water meter setter. 8. At stations 6 + 54.09 and 5 + 29 .37 need to have two inch gate valves on the Tees. 9. The thrust block at station 18 + 50.44 need to be a ecology block, so the water may be turned back on after the connection is done. 10. The connection to the existing main on sheet 14 - drawing C6.3 is a ten inch main. Reviewed by: Edward Smith, John I Signed by: Edward Smith <DC90029353CCCD468AA2A2858FFCD8F54F4116@server1.ci.yelm.wa.us> Water FW%3A T T Fairway Multi-Family Housing Plan Review Public Works.doc.EML Jim Gibson Roberta Allen 11.0 Roberta Allen EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_allen r_allen@ci.yelm.wa.us r_allen 458-3835 Community Development Roberta Allen SMTP r_allen@ci.yelm.wa.us Roberta Allen r_allen Edward Smith EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=Smitty smitty@ci.yelm.wa.us smitty Public Works Edward Smith Edward Smith Smitty image001.gif .gif image001.gif image001.gif image/gif image001.gif@01C8359B.3906D050 image002.gif .gif image002.gif image002.gif image/gif image002.gif@01C8359B.3906D050 image003.gif .gif image003.gif image003.gif image/gif image003.gif@01C8359B.3906D050