Loading...
SRP-05-0673 Engineering Review No 2 092607IPM.Note Steve -Comments for Del's Farm Supply Review # 2 Roberta Allen Steve Harrington Roberta Allen EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=STEVEH Comments for Del's Farm Supply Review # 2 EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_ALLEN EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_ALLEN Steve Harrington EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=STEVEH Roberta Allen Steve -Comments for Del's Farm Supply Review # 2 Roberta: The following are 2nd review comments for the Del’s Farm Supply. 1. Item number 24 from the previous review # 1comments list, the infiltration pond elevation is at 346 this only 2 feet higher than the high ground water. This does not meet the City of Yelm or the 1992 D.O.E. requirements. 2. Item number 30 from the previous review # 1 comments list, the bottom of the wet pond elevation does not meet the required 6 feet of separation between the high ground water mark and bottom of wet pond. This does not meet the City of Yelm or the 1992 D.O.E. requirements. 3. Item # 44 from the previous review # 1 comments, the pavement design should be submitted on the current set of civil plans being reviewed. 4. Item # 45 from the previous review # 1 comments, the wet pond does not meet separation requirements. 5. Item # 49 from the previous review # 1 comments, should this be included in the step sewer plans? Step sewer has an end of line clean out, water lines have blow-offs. 6. Item # 50 from the previous review # 1 comments, I believe the location of the step line coming out of the step tank should not be coming out of the side of the step tank as shown on plans and should be located at the front of the step tank to meet City of Yelm requirements. This item should also be included in the step sewer items, not water items. 7. Item # 58 from the previous review # 1 comments please check the City of Yelm Step Tank Details 7-9 and 7-11 for step tank installation. 8. Item # 65 from the previous review # 1 comments The City of Yelm Standards or Details for sewer installation are located on the Step Sewer Details sheet on sheet 10 of 13. 9. Item # 66 from the previous review # 1 comments, clean out detail # 7-20 has been added to sheet 11 of 13 not, sheet 13. 10. Item # 71 from the previous review # 1 comments, please add Backflow Devices Detail to the water detail sheet 12 of 13. Thank you, Steve H <DC90029353CCCD468AA2A2858FFCD8F5426999@server1.ci.yelm.wa.us> Comments for Del's Farm Supply Review %23 2.EML Steve Harrington Roberta Allen 11.0 Roberta Allen EX /O=CITYOFYELM/OU=FIRST ADMINISTRATIVE GROUP/CN=RECIPIENTS/CN=R_allen r_allen@ci.yelm.wa.us r_allen 458-3835 Community Development Roberta Allen Roberta Allen r_allen