Loading...
DGSewerDetail7-11ALL STEP TANKS SHALL BE H-20 LOAD RATED TANKS. THIS POLICY SHALL TAKE EFFECT ON MAY 31, 2007. GRADE 21"0 MIN.PVC RISER I WITH WATER TIGHT I LIDS II 14 GAUGE TONING I WRE TO SS C0~ ~ I V-1 I I I I I I N I I I I 4"OI OR FICE I I I i I ~ p ~ ~ ~ N I I o V 2 I ~B AFFLE I m (NOTE 1) ~ L--.-J TIGHT LID I~PUMP VAULT RISER j 14 GAUGE TONING I~WIRE TO SERVICE I BOX ~ 1 I 2 PART USE ORCNO TANK TO RISER ADAPTER FOR CONCRETE TANKS PUMP ASSEMBLY, SEE DWG. NO. 7-9 6" MIN BEDDING 1500 GAL 3000 GAL 4500 GAL D-7 2 60" 72" 72" D-2 2 43" 66" 55" D-3 2 50" 62" 62" V-1 400 GAL 600 GAL V-2 1100 GAL 2400 GAL NOTES: 1. DELETE BAFFLE FOR A 3000 GALLON TANK UTILIZED AS A TRIPLEX PUMP VAULT. 2. THE OWNER WILL REVIEW TOLERANCES IN EXCESS OF DIMENSIONS SHOWN. 3. THE TRIPLEX PUMP VAULT REQUIRES TWO VAULTS AND TWO COMPLETE RISERS. ONE VAULT CONTAINS FLOATS AND ONE PUMP. THE SECOND VAULT CONTAINS TWO PUMPS. 4. 4500 GALLON TANKS OR LARGER SHALL HAVE THREE RISERS AND LIDS. ON ALL TANKS LARGER THAN 1500 GALLONS THE LENGTH OF THE DOWN TURNED INLET PIPE WILL BE DETERMINED BY THE YELM SEWER DEPT. CITY OF YELM DEPT. OF PUBLIC WORKS 1500, 3000, 4500 GALLON STEP TANK/PUMP TANK APPROVED DWG. NO. PUBLIC WORKS DIRECTOR DATE DES. DWN. CKD. DATE JY JEG TP 4/2007