ep^9-2-08^090208^Prairie Park Hotel
REPORT OF EPOXY INSPECTION
Report #E 090208
CLIENT:
Prairie Park Holdings, LLC
PROJECT:
Prairie Park Hotel Expansion
ATTN:
Bill Lindgren
PROJECT ADDRESS:
700 Prairie Park Lane
ADDRESS:
P.O. Box 5210
PROJECT #:
08S035
DATE INSPECTED:
September 2, 2008
PERMIT #:
SPR-07-0275-4L
FIELD DATA
Reason for epoxy inspection:
Shown on plans or specs
Intentionally omitted during original placement
Other:
Re-inspection*
Needs Engineer’s review and acceptance*
Product Name:
Simpson Set 22
Approved by Engineer:
Yes No
Batch #:
13518255
Manufacture Date:
Exp. Date or Shelf Life:
7/31/10
Batch #:
Manufacture Date:
Exp. Date or Shelf Life:
Location:
PHD2 and PHD5 hold downs
Hole Depth:
9 1/2 +
Hole Diameter:
3/4"
Location:
Hole Depth:
Hole Diameter:
Threaded Rod
Reinforcing Bar
Holes properly cleaned prior to epoxy installation
Anchors installed in accordance with manufacturers instructions, specifications, and corresponding evaluation report (ER-1772)
*Any Deficiencies Noted: Engineer’s Approval Other
REMARKS:
Holes spaced throughout per plans for wall hold downs, 15 total.
REPORTED BY:
B. Parnel, ACI Field Inspector
REVIEWED BY:
M. Southard, WABO Technical Director
DISTRIBUTION: