ep^9-2-08^090208^Prairie Park Hotel REPORT OF EPOXY INSPECTION Report #E 090208 CLIENT: Prairie Park Holdings, LLC  PROJECT: Prairie Park Hotel Expansion  ATTN: Bill Lindgren  PROJECT ADDRESS: 700 Prairie Park Lane  ADDRESS: P.O. Box 5210  PROJECT #: 08S035     DATE INSPECTED: September 2, 2008     PERMIT #: SPR-07-0275-4L   FIELD DATA Reason for epoxy inspection:  Shown on plans or specs  Intentionally omitted during original placement    Other:    Re-inspection*  Needs Engineer’s review and acceptance*   Product Name: Simpson Set 22 Approved by Engineer:   Yes  No  Batch #: 13518255 Manufacture Date:  Exp. Date or Shelf Life: 7/31/10  Batch #:  Manufacture Date:  Exp. Date or Shelf Life:   Location: PHD2 and PHD5 hold downs Hole Depth: 9 1/2 + Hole Diameter: 3/4"  Location:  Hole Depth:  Hole Diameter:      Threaded Rod  Reinforcing Bar   Holes properly cleaned prior to epoxy installation   Anchors installed in accordance with manufacturers instructions, specifications, and corresponding evaluation report (ER-1772)   *Any Deficiencies Noted:  Engineer’s Approval  Other REMARKS: Holes spaced throughout per plans for wall hold downs, 15 total.             REPORTED BY: B. Parnel, ACI Field Inspector  REVIEWED BY: M. Southard, WABO Technical Director   DISTRIBUTION: original: joant@prairiepark.com  cc: dennis@andersonboone.com  cc: mike@mc2-inc.com   cc: garyc@ci.yelm.wa.us  cc: amy@sheacarrjewell.com  cc: blindgren@cblconsultingservice.com