20190053 2019-50 Customer Approval Set 5-30-19MOD A2019-50-1AMOD B2019-50-1BMOD C2019-50-1CTRUCKHITCHENDTRUCKHITCHENDTRUCKHITCHENDELEC.PANELOUTDOORHEAT PUMPSTYP.CONC. SIDEWALK/LANDINGSSAN. SEWER(VERIFY)WATER(VERIFY)MOD AA1011SIM101A1011Ref1Ref1Ref1Ref0NameElevation11A101SIM1A101SIM1iELEVATION BUBBLESECTION BUBBLEDETAIL BUBBLEDETAIL CALLOUTGRID BUBBLEELEVATION LEVELMODULE TAGDOOR TAGWINDOW TAGREVISION TAGCENTERLINE1iWALL TAG1KEYNOTENORTH ARROWTYPICAL SYMBOLS LEGENDGENERAL NOTES1.THE TERM IBC SHALL APPLY TO THE CURRENT EDITION OF THE INTERNATIONAL BUILDING CODE (IBC) AS AMENDED BY THE STATES OF OREGON AND WASHINGTON. FOR PROJECTS IN ALL OTHER STATES IT SHALL APPLY TO THE CURRENT EDITION OF THE UBC OR IBC AS ADOPTED BY THAT STATE.2.ALL CONTROLS AND HARDWARE SHALL BE ACCESSIBLE TO PERSONS WITH DISABILITIES.3.LOCAL JURISDICTION TO DETERMINE COMPLIANCE WITH IBC CHAPTER 29 (WITH REGARD TO ADJACENT FACILITIES) IN ACCORDANCE WITH THEIR CURRENTLY ADOPTED EDITION OF THE IBC.4.WHERE REQUIRED, PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN ACCORDANCE WITH 2015 IFC SECTION 9065.PER WAC 296-150F-0605 REQUIRES TOILET FACILITIES LOCATED IN AN ADJACENT FACILITY TO BE NOTED ON THE PLAN SUBMITTAL AND THAT THE REQUIREMENTS OF IBC CHAPTER 29, SECTION 2902, TABLE 2902.1 OF THE STATE BUILDING CODE MUST BE VERIFIED BY THE LOCAL JURISDICTION BUILDING OFFICIAL AND SHOWN ON THE NLEA.6.IF APPLICABLE, FIRE ALARM SYSTEM TO BE FIELD INSTALLED (BY OTHERS) PER 2015 IBC SECTION 907.2.3, GROUP E. SEE ELECTRICAL PLAN FOR DEVICE LOCATIONS. FIRE ALARM INSPECTION AND APPROVAL PER LOCAL AUTHORITY HAVING JURISDICTION.7.IF APPLICABLE, FIRE SAFETY AND EVACUATION PLANS SHALL BE PROVIDED BY OWNER PRIOR TO CERTIFICATE OF OCCUPANCY PER 2015 IFC SECTION 4038.AN ACCESSIBLE ROUTE SHALL BE PROVIDED TO THE BUILDING AREA AS REQUIRED IN 2015 IBC SECTION 1104ABBREVIATIONSA.B.ADJ.A.F.F.ALBABD.BLK.B.O.BOT.BRCHBV.CDR.CJCLCLG.CLR.CMUC.O.CONC.CONT.CPTDBL.DFDIA.DIM.DSDTLDWEA.ELEC.ELEV.EQUIP.EXIST.EXT.E.W.ANCHOR BOLTADJUSTABLEABOVE FINISH FLOORALUMINUMBRONZE ANODIZEDBOARDBLOCKBOTTOM OFBOTTOMBIRCHBOTTOM VENTCEDARCONTROL JOINTCENTERLINECEILINGCLEARCONCRETE MASONRY UNITCLEAN OUTCONCRETECONTINUOUSCARPETDOUBLEDRINKING FOUNTAINDIAMETERDIMENSIONDOWNSPOUTDETAILDISHWASHEREACHELECTRICALELEVATIONSEQUIPMENTEXISTINGEXTERIOREACH WAYFDFDNF.E.F.E.C.FGLFLR.FIN.F.O.FIN.F.O.FRMFSGA.GALV.GLBGYP.HBHCHFHMHSSINFO.INSUL.INT.KDL.LAVLHLHOSLVLFLOOR DRAINFOUNDATIONFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFIBERGLASSFLOORFINISHFACE OF FINISHFACE OF FRAMINGFLOOR SINKGAUGEGALVANIZEDGLULAM BEAMGYPSUMHOSE BIBHOLLOW COREHEM FIRHOLLOW METALHOLLOW STRUCTURAL SECTIONINFORMATIONINSULATIONINTERIORKNOCK DOWNLONGLAVATORYLEFT HANDLEFT HAND OUT SWINGLAMINATED VENEER LUMBERMAX.MECH.MFR.MIN.MISC.MODMPLMTL.MVN.I.C.NOM.NRWNTSOBSO.C.OFCIOFOIOPP.O.S.B.PDPFPLAMPLCSPLYWDPNTP.T.REFRIG.REQ'DRHRHOSR.O.MAXIMUMMECHANICALMANUFACTURERMINIMUMMISCELLANEOUSMODULEMAPLEMETALMIXING VALVENOT IN CONTRACTNOMINALNARROW (LITE)NOT TO SCALEOBSCUREON CENTEROWNER FURNISHED CONTRATOR INSTALLEDOWNER FURNISHED OWNER INSTALLEDOPPOSITEORIENTED STRAND BOARDPUNCH & DIMPLEPREFINISHEDPLASTIC LAMINATEPLACESPLYWOODPAINTPRESSURE TREATEDREFRIGERATORREQUIREDRIGHT HANDRIGHT HAND OUT SWINGROUGH OPENINGSCSFSHSHT.SHTG.SIM.SIMP.SQ.S.S.STN.STRUCT.TIM.TMPT.O.TTPTYP.U.N.O.URVCTV.C.VWSW/WCWD.WHSOLID CORESTOREFRONTSINGLE HUNGSHEETSHEATHINGSIMILARSIMPSONSQUARESTAINLESS STEELSTAINSTRUCTURALTIMELYTEMPERED SAFETY GLAZINGTOP OFTAPE, TEXTURE & PAINTTYPICALUNLESS NOTED OTHERWISEURINALVINYL COMPOSITION TILEVINYL COATEDVINYL WRAP SURROUNDWITHWATER CLOSETWOODWATER HEATERSYSTEM COMMISSIONING NOTES1.PRIOR TO CONSTRUCTION, A COMMISSIONING PLAN SHALL BE DEVELOPED PER WSEC C408.1.2. THE COMMISSIONING PLAN SHALL BE USED DURING CONSTRUCTION TO INSURE PROPER INSTALLATION, TESTING AND BALANCING OF BUILDING SYSTEMS AS FOLLOWS:MECHANICAL SYSTEM PER WSEC C408.2NOT REQUIRED (EXCEPTION)LIGHTING AND CONTROLS PER WSEC C408.3NOT REQUIRED (EXCEPTION #1 AND #2)SERVICE WATER HEATING PER WSEC C408.4NOT REQUIRED (EXCEPTION #1)ENERGY METERING PER WSEC C408.6NOT REQUIRED (PER C409.1)ENERGY CODE NOTES1.ALL BUILDING THERMAL ENVELOPE INSULATION SHALL BE MARKED INACCORDANCE WITH OEESC 303.1.1 AND/OR WSEC C303.1.1 AND INSTALLEDPER OEESC 303.1.2 AND/OR WSEC C303.1.22.BLOWN-IN INSULATION SHALL BE INSTALLED AND CERTIFIED PER OEESC 303.1.1.1 AND/OR WSEC C303.1.1.13.ALL AIR BARRIER MATERIALS SHALL BE ASTM E2178 RATED OR AS LISTED IN OEESC 502.4.1.2.1 AND/OR WSEC C402.5.1.14.AIR BARRIER COMPLIANCE OPTIONS:CONTINUOUS AIR BARRIER FOR THE OPAQUE BUILDING ENVELOPE SHALL COMPLY WITH OEESC 502.4.1.2.1AIR BARRIER TESTING AND REPORTING TO BE CONDUCTED PER WSECC402.5.1.2 FOR THE STATE OF WASHINGTON5.PENETRATIONS OF THE AIR BARRIER SHALL BE CAULKED, GASKETED OR SEALED PER OEESC 502.4.2 AND/OR WSEC C402.5.1.16.ALL FENESTRATION ASSEMBLIES SHALL BE LABELED BY THE MANUFACTURER PER OEESC 303.1.3 AND 502.4.1 AND/OR WSEC C303.1.3 AND C402.4.37.AIR ECONOMIZER SHALL BE CAPABLE OF PROVIDING 100% OUTSIDE AIR PER OEESC 503.3.1 AND/OR WSEC C403.3.3.18.ECONOMIZER HIGH-LIMIT SHUTOFF CONTROL IS ELECTRONIC ENTHALPY PER MANUFACTURER'S SPECIFICATIONS AND WSEC C403.3.3.39.MECHANICAL VENTILATION SYSTEM SHALL HAVE THE CAPABILITY TO REDUCE THE OUTSIDE AIR SUPPLY TO THE MINIMUM REQUIRED PER OEESC 503.2.5 AND WSEC C403.510.OUTSIDE AIR AND EXHAUST AIR DAMPERS SHALL BE RATED PER OEESC 502.4.4 AND 503.2.4.5 AND/OR WSEC C402.5.5 AND C403.2.411.THIS PROJECT PROVIDES TWO ADDITIONAL EFFICIENCY PACKAGE OPTIONS PER 2015 WSEC, SECTION C406.A.ENERGY ADD OPTION #1 IS WSEC C406.1 (ITEM #2); C406.3 REDUCED LIGHTING POWER DENSITY. INSTALLED LIGHTING WATTAGE IS LESS THAN 75% OF ALLOWED INTERIOR LIGHTING WATTAGE WSEC C405.4.2(1) OR C404.4.2(2)B.ENERGY ADD OPTION #2 IS WSCE C406.1 (ITEM #3); C406.4 ENHANCED LIGHTING CONTROLS. NO LESS THAN 90% OF ALL INTERIOR LIGHTING IS CONTROLLED WITH CONTINUOUS DIMMING ALONG WITH EXCEPTION #3 OF WSEC 406.412.THIS PROJECT MEETS DEDICATED OUTDOOR AIR SYSTEM REQUIREMENTS PER WSEC C403.6, EXCEPTION #1, NATURAL VENTILATION AREAS AT OPERABLE WINDOWS IS GREATER THAN 4% OF FLOOR AREA (SEE NATURAL VENTALATION SCHEDULE IN THE MECHANICAL SHEETS) OR OUTDOOR AIR BY ERV AS SHOWN ON MECHANICAL DRAWINGSPLEASE REVIEW AND COMMENT ON THESEDOCUMENTS. PLEASE RETURN APPROVED SETOR COMMENTS BY 05-31-19FAILURE TO RESPOND BY THIS DATE COULDCAUSE DELAYS, INCREASED COSTS, INABILITYTO INCORPORATE YOUR CHANGES OR ALLOF THE ABOVEDATEBYAPPROVEDCUSTOMER APPROVALAPPROVED EXCEPT AS NOTEDREVISE AS NOTED & RESUBMITJOB#SHEET #DATESHEETPROJ.ADDRESSREUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION.DRWTELEPHONE: (503) 749-4949 FAX: (503) 749-4950P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com MODERN BUILDING SYSTEMS, INC. 2019MODERN BUILDING SYSTEMS, INC.© 2019-DH-50A 0.05/30/19 PRELIM.COVER SHEET401 COATES AVE. NW, YELM, WA 98597YELM SD VIIITS42' x 68' MODULAR OFFICESHEET INDEXSHT. NO. SHEET NAME Current Rev. Rev Issued ByA 0.0 COVER SHEETA 0.1 FIRE & LIFE SAFETY PLANA 1.0 FLOOR PLANA 2.0 EXTERIOR ELEVATIONSA 3.0 FINISH NOTES AND DETAILSA 4.0 INTERIOR ELEVATIONSE 0.1 ELEC. PANELS & LOAD CALCS.E 1.0 ELEC. POWER & LIGHTING PLANSM 1.0 HVAC PLAN AND NOTESKCDA - YELM SD VIII42' x 68' MODULAR OFFICE 1/8" = 1'-0"1SITE LAYOUTREV. DESCRIPTIONDATE BY 10' - 0"8' - 0"9' - 0"14' - 0"9' - 0"2' - 6"4' - 6"21' - 0"23' - 0"11' - 6"15' - 0"7' - 6"15' - 0"10' - 6"10' - 0"23' - 0"11' - 6"15' - 0"11' - 6"10' - 0"14AFBCDE2964B227'-0"B241'-0"B248'-0"B426'-6"B253'-6"B229'-6"B1437'-0"B1161'-0"BREAKROOMJAN.OFFICE #1OFFICE #2OFFICE #3WORK ROOMOFFICE #4OFFICE #5RESTROOM#1RESTROOM#2OPEN OFFICE23HALLWAYGENERAL:CONSTRUCTION TYPEOCCUPANCY GROUPOCCUPANCY LOADDISTANCE TO PROPERTY LINE OR ASSUMED PROPERTY LINEELECTRICAL:ELECTRICAL SERVICE LOADMECHANICAL:VENTILATION OCCUPANCY LOADCLIMATE ZONEHEATINGAIR-CONDITIONINGPLUMBING:PLUMBING OCCUPANCY LOADQUANTITY OF PLUMBING FIXTURESSTRUCTURAL:SPECIAL INSPECTIONS REQUIREDFLOOR LIVE LOADWIND LOADVB (NON-SPRINKLERED)B39NORTH: 10' MIN.SOUTH: 10' MIN.EAST: 10' MIN.WEST: 10' MIN.200A / 120/208V / 3 PH.30.0 kVA54C/5BSPV/HPYES40 (20 MALE/20 FEMALE)7Lambda = 1.0Vult = 140 MPH(Vasd = 108 MPH)3 SECOND GUST - EXP. BBEARING WALL SYSTEM:SS = 1.251,Fa = 1.000SDS = 0.834, RISK CATEGORY IIDESIGN CRITERIASEISMICCEILING GRID W/ BERC CLIPS, STEEL COLUMN WELDING50 PSF, 15 PSF (PARTITION), 100 PSF (ASSEMBLY & HALLWAY)Ie = 1.0, SEISMIC DESIGN CATEGORY D, SITE CLASS DEXTERIOR WALL RATING (TABLE 602)FIRE SEPARATION DISTANCE 10' OR GREATER, NO RATING REQUIREDEXITS REQUIRED1EXIT ACCESS TRAVEL DISTANCE200 FEETROOF SNOW LOAD30 PSFBUILDING AREA2839 SQ. FT.EXIT LOADCOMMON PATH DISTANCEFIRE AND LIFE SAFETY SYMBOLS LEGENDOCC. GROUPOCC. LOADCOMMON PATH OF EGRESSEXIT ACCESS PATH OF EGRESSEGRESS START POINTEGRESS DIRECTIONXXX'-X"X'-X"EXIT ACCESS DISTANCE10FIRE AND LIFE SAFETY PLAN NOTES1.FIRE DEPARTMENT KEY BOX AND LOCATION TO BE PROVIDED BY OTHERS2.FIRE EXTINGUISHERS TO BE 5LB 2A:108:C - BY OTHERS3.BUILDING ADDRESS IDENTIFICATION AND LOCATION TO BE PROVIDED AND MAINTAINED BY OTHERSKENNETHA.RASMU S S E NSTATEOFWASHINGTON 21543REGISTEREDP R O FESSIONALENGINEERJOB#SHEET #DATESHEETPROJ.ADDRESSREUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION.DRWTELEPHONE: (503) 749-4949 FAX: (503) 749-4950P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com MODERN BUILDING SYSTEMS, INC. 2019MODERN BUILDING SYSTEMS, INC.© 2019-DH-50A 0.15/30/19 PRELIM.FIRE & LIFE SAFETY PLAN401 COATES AVE. NW, YELM, WA 98597YELM SD VIIITS42' x 68' MODULAR OFFICE 1/4" = 1'-0"1FIRE & LIFE SAFETY PLANOCCUPANT LOAD SCHEDULEFUNCTION OF SPACE AreaLOADFACTOROCCUPANTLOADASSEMBLY (UNCONCENTRATED) 195 SF 15 14BUSINESS 2503 SF 100 26Total39REV. DESCRIPTIONDATE BY 14AFBCDE5' - 0"6' - 0"5' - 0"4' - 0"6' - 0"4' - 0"9' - 6"5' - 6"6' - 0"5' - 0"3' - 0"6' - 0"3' - 0"3' - 10"6' - 0"4' - 0"1' - 2"6' - 0"2' - 6"1' - 10"4' - 9"6' - 0"1' - 3"4' - 0"6' - 0"3' - 10"3' - 0"10' - 10"13' - 10"2"13' - 10"2"13' - 10"41' - 10"18' - 0"6' - 0"32' - 0"12' - 0"68' - 0"BREAKROOMOPEN OFFICEOFFICE #1OFFICE #2OFFICE #3WORK ROOMOFFICE #4OFFICE #5RESTROOM#1RESTROOM#2A 4.043A 4.01A 4.054' - 9"6' - 7 1/2"6' - 7 1/2"4' - 2"9' - 8"6' - 0"7' - 10"4' - 10"9' - 0"9' - 0"17' - 0"6' - 0"6' - 0"6' - 0"7' - 0"6' - 0"8' - 0"6' - 0"5' - 0"1510238976BBBBBABCCCB4'-0" x 6'-8"FINISHEDOPENING3'-0" x 6'-8"FINISHEDOPENINGPRINTER/COPIERJAN.42' - 5"2' - 5"ELEC. PANELCLR. FLR.SPACE20 GAL. WH ONSHELF ABV.MOP SINKA 4.02REFRIG.(BYOTHERS)MOD AMOD BMOD C2' - 4" +/-4' - 6" +/-6' - 0" +/-A 1.02OUTDOORHEAT PUMPSTYP.234'-2" x 6'-8"FINISHEDOPENINGHALLWAY2 x 6 PLUMB. WALL - TYP.16' - 0"14' - 0"26' - 0"12' - 0"SIMP. HRS416Z W/ (6)1/4" DIA. x 3" L. SDS SCREWSEA. END, (2) PLACESVERTICAL TIE-DOWN(2) PLACES(7) 5/8" DIA. M.B.'S W/ NUTS ANDWASHERS - 1'-0" FROM ENDSAND EA. SIDE OF COLUMNSMARRIAGE LINE WALLSW/ 7/16" O.S.B. SHTG.W/ 15 GA. STAPLESAT 6" & 8" - TYP.SIMP. CS18 W/ (4) N10'SEA. END, FROM STUDTO FLOOR RIM - TYP.O.S.B. SHTG.ON THIS SIDEOF WALLDRINKING FOUNTAINW/ BOTTLE FILLER(BY OTHERS)EQ.EQ.1' - 11 1/2"HEATPUMPWALL BRACKET W/ (3) SIMP. 1/4" DIA. x 4-1/2" L. SDS SCREWS AT EA. LEG (6) SCREWS TOTALALIGN 2 x 6 STUDS W/WALL BRACKET - TYP.VERIFY WIDTH OF FOROUTDOOR UNIT USEDKENNETHA.RASMU S S E NSTATEOFWASHINGTON 21543REGISTEREDP R O FESSIONALENGINEERJOB#SHEET #DATESHEETPROJ.ADDRESSREUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION.DRWTELEPHONE: (503) 749-4949 FAX: (503) 749-4950P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com MODERN BUILDING SYSTEMS, INC. 2019MODERN BUILDING SYSTEMS, INC.© 2019-DH-50A 1.05/30/19 PRELIM.FLOOR PLAN401 COATES AVE. NW, YELM, WA 98597YELM SD VIIITS42' x 68' MODULAR OFFICE 1/4" = 1'-0"1FLOOR PLAN 1 1/2" = 1'-0"2HEAT PUMP MOUNTING DETAILREV. DESCRIPTIONDATE BY Sub-Floor0' - 0"Roof / Plate8' - 1 1/8"14WINDOW TRIM - TYP.CORNER BATT - TYP.MIN.6' - 0"19' - 0"18' - 0"19' - 0"MIN.6' - 0"ROOF FALL PROTECTION ANCHOREACH MOD (8) TOTAL23Sub-Floor0' - 0"Roof / Plate8' - 1 1/8"AFBCDESHIPPING HEIGHT= +/- 15' - 8 1/2"123MOD BATT W/ (2) ROWSOF 6d AT 6" O.C. - TYP.Sub-Floor0' - 0"Roof / Plate8' - 1 1/8"14P.T. 2 x 8 x 8'-0" UNDER DOORSIN PLACE OF OFFSET RIM - TYP.23Sub-Floor0' - 0"Roof / Plate8' - 1 1/8"AFBCDETYP. INSIGNIALOCATION12312" x 12" OPENING FORO/A AND E/A (2) PLACES4' - 9" TYP.2' - 10 1/2" +/-7' - 1" +/-3' - 10 1/2" +/-9' - 9 1/2" +/-KENNETHA.RASMU S S E NSTATEOFWASHINGTON 21543REGISTEREDP R O FESSIONALENGINEERJOB#SHEET #DATESHEETPROJ.ADDRESSREUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION.DRWTELEPHONE: (503) 749-4949 FAX: (503) 749-4950P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com MODERN BUILDING SYSTEMS, INC. 2019MODERN BUILDING SYSTEMS, INC.© 2019-DH-50A 2.05/30/19 PRELIM.EXTERIOR ELEVATIONS401 COATES AVE. NW, YELM, WA 98597YELM SD VIIITS42' x 68' MODULAR OFFICE 1/4" = 1'-0"4WEST ELEVATION 1/4" = 1'-0"3NORTH ELEVATION 1/4" = 1'-0"1EAST ELEVATION 1/4" = 1'-0"2SOUTH ELEVATIONREV. DESCRIPTIONDATE BY ROOF CONSTRUCTION (MODS 'A' & 'C')ROOFING: FIBERGLASS COMP. SHINGLES OVER (2) LAYERSSYNTHETIC FELT (MIN. CLASS B), (6) STAPLESSHEATHING: 7/16" O.S.B. (24/16) AND CEDAR TEXTURE PANEL (NO GROOVES) FACE DOWN AT EXPOSED OVERHANGS(ACTS AS AIR BARRIER)FRAMING: 2 x 10 DF #2 AT 24" O.C.BEAMS: (2) MURPHY LVL 3100 Fb 2.0E, 1-1/2" W x 24" D(ESR-1387 AND ESR-2913)INSULATION: R-42 (CELLULOSE) W/ FS-25(ACTS AS 1 PERM MAX. VAPOR BARRIER)OVERHANG: 16"ROOF PITCH: 3 IN 12CORNER BATTS: 1 x 4FASCIA: 1 x 6BARGE: 1 x 6WINDOW/DOOR TRIM: 1 x 4GUTTERS: 4" K-LINE (PREFINISHED)DOWNSPOUTS: 2" x 3" RECT. (PREFINISHED)FLOOR CONSTRUCTIONFINISH: SHEET VINYL AT RESTROOM, BALANCE BY OTHERSBASE: BY OTHERSUNDERLAYMENT: 11/32" CCP AT SHEET VINYLSUBFLOOR: 23/32" APA RATED SHEATHING (24)(ACTS AS 1 PERM MAX. VAPOR BARRIER)(ACTS AS AIR BARRIER)JOISTS: 2 x 8 DF #2 AT 16" O.C., DBL. 2 x 8 AT ENDS (U.N.O.)RIM JOISTS: DBL. MURPHY LVL 3100 Fb - 2.0E, 1-1/2" W x 7-1/4" D (ESR-1387 AND ESR-2913)OFFSET RIMS: 2 x 4 DF (U.N.O.)INSULATION: R-30 U (FIBERGLASS BATTS)BOTTOM CLOSURE: FS-25EXTERIOR WALL CONSTRUCTIONPLATE HEIGHT: 8'-1 1/8"SIDING: 15/32" T1-11 (16) W/ 8" VERT. GROOVESSHEATHING: NONESTUDS: 2 x 6 DF STUD GRADE AT 16" O.C. W/ BARRIER WRAP AT EXTERIOR (ACTS AS A WATER RESISITIVE BARRIER)INSULATION: R-21 U (FIBERGLASS BATTS)HEADERS TO BE (2) 2x W/ MIN. R-10 INSULATION BETWEEN. SEE DOOR AND WINDOW SCHEDULE FOR SIZE.INTERIOR FINISH: 5/8" V.C. GYPSUM BOARD(ACTS AS 1 PERM. MAX. VAPOR BARRIER)(ACTS AS AIR BARRIER)SKIRT: 15/32" P.T. PLYWOOD, PRIME & PAINT (SAND FINISH)INTERIOR WALL CONSTRUCTIONPLATE HEIGHT: FULL HEIGHTSTUDS: 2 x 4 HF STUD GRADE AT 16" O.C. (U.N.O.)INSULATION: R-11 MINERAL WOOL SOUND BATTSINTERIOR FINISH: 5/8" V.C. GYPSUM BOARDF.R.P. OVER WATER RESISTANT GYPSUM BOARD AT RESTROOMSCEILING NOTESCEILING HEIGHT: NOMINAL 8'-0" (U.N.O.)CEILING: SUSPENDED T-GRID W/ ACOUSTIC TILE(REF: ESR-1308)INSTALL ARMSTRONG 7301 HEAVY DUTY MAIN W/ 7/8" ANGLE & BERC CLIPSSPECIAL INSPECTION REQUIRED IN SEISMIC DESIGN CATEGORIES C, D, E & F EXTERIOR NOTESSUB-ROOF CONSTRUCTION (MODS 'B')ROOFING: FULLY ADHERED 45 MIL EPDM OR TPOSHEATHING: 7/16" O.S.B. (24/16) (ACTS AS AIR BARRIER)FRAMING: 2 x 10 DF #2 AT 24" O.C.BEAMS: (4) MURPHY LVL 3100 Fb 2.0E, 1-1/2" W x 24" D(ESR-1387 AND ESR-2913) DISCONTINUOUS AT GRID '3'INSULATION: R-42 (CELLULOSE) W/ FS-25(ACTS AS 1 PERM MAX. VAPOR BARRIER)OVERHANG: NONEROOF PITCH: NONEROOF CONSTRUCTION (MOD 'B')ROOFING: FIBERGLASS COMP. SHINGLES OVER (2) LAYERSSYNTHETIC FELT (MIN. CLASS B), (6) STAPLESSHEATHING: 7/16" O.S.B. (24/16) AND CEDAR TEXTURE PANEL (NO GROOVES) FACE DOWN AT EXPOSED OVERHANGS(ACTS AS AIR BARRIER)FRAMING: 2 x 4 DF #2 AT 24" O.C.BEAMS: NONEINSULATION: NONEOVERHANG: 16"ROOF PITCH: 3 IN 12DOOR ROUGH OPENING SCHEDULEAR.O. WIDTHR.O. HEIGHTEXTERIOR DOORSBCDE1E2FGINTERIOR DOORS12345NOTE: ALL TRIMMER HEIGHTS = R.O. CALL SIZE MINUS 1-1/2"METAL DOORS W/ HOLLOW METAL FRAME (WELDED)CALL SIZE + 4-1/2"CALL SIZE + 2-1/8"R.O. WIDTHR.O. HEIGHTDBL. METAL DOORS W/ HOLLOW METAL FRAME (WELDED)CALL SIZE + 4-1/2"CALL SIZE + 2-1/8"R.O. WIDTHR.O. HEIGHTSTOREFRONT DOORCALL SIZE + 4-1/2"CALL SIZE + 2-1/8"R.O. WIDTHR.O. HEIGHTTIMELY SPLIT MEDIA DOORCALL SIZE + 1-1/4"CALL SIZE + 1"R.O. WIDTHR.O. HEIGHTMETAL DOOR W/ WOOD FRAME (PEASE AND STANLEY) (INSWING)CALL SIZE + 2"CALL SIZE + 2"R.O. WIDTHR.O. HEIGHTMETAL DOOR W/ WOOD FRAME (PEASE AND STANLEY) (OUTSWING)CALL SIZE + 2"CALL SIZE + 1-9/16"R.O. WIDTHR.O. HEIGHTMETAL DOOR W/ METAL FRAME (FAST-FRAME)CALL SIZE + 1-1/4"CALL SIZE + 1"R.O. WIDTHR.O. HEIGHTMETAL DOOR W/ HOLLOW METAL FRAME (KNOCK-DOWN)CALL SIZE + 2"CALL SIZE + 1"R.O. WIDTHR.O. HEIGHTHOLLOW / SOLID WOOD DOOR W/ WOOD FRAMECALL SIZE + 2"CALL SIZE + 2-1/8"R.O. WIDTHR.O. HEIGHTTIMELY FRAMECALL SIZE + 1-1/4"CALL SIZE + 1"R.O. WIDTHR.O. HEIGHTPOCKET DOOR2x CALL SIZE + 2"CALL SIZE + 4"R.O. WIDTHR.O. HEIGHTBI-PASS DOORCALL SIZECALL SIZE + 2-1/8"R.O. WIDTHR.O. HEIGHTBI-FOLD DOORCALL SIZECALL SIZE + 5/8"RIM JOIST TO FLOOR JOISTJOIST TO JOISTBLOCKINGSTUDS TO PLATES - END NAILSTUDS TO PLATES - END NAILBLOCKINGJAMB STUD TO 4x HEADERJAMB STUD TO 2x HEADERSTUD TO STUD (CRIPPLE, ETC.)UPPER TOP PLATE TO LOWERTOP PLATEBOTTOM PLATE TO FLOORRIM JOIST TO RAFTERRIM JOIST TO TRUSSRAFTER TO RAFTERBLOCKING2 x 4 LEDGER2x BRACE TO RAFTER3 PER JOIST2 ROWS AT 12" O.C.2 EACH END2 EACH END AT 2 x 43 EACH END AT 2 x 62 EACH ENDMIN. 4 EACH ENDMIN. 2 EACH END8" O.C.2 EACH SIDE OF STUD2 EACH SIDE OF STUD3 PER RAFTERMIN. 2 PER TRUSS2 ROWS AT 12" O.C.2 EACH END2 ROWS AT 6" O.C.4 AT RAFTERCONNECTIONNO. / SPACINGFLOORWALLROOFMINIMUM NUMBER OF NAILS FOR WOOD MEMBERS(EXCEPT AS NOTED ON DRAWINGS)NOTES: 1.ALL FASTENERS ARE 12d (.131), USE HDG FASTENERS OR EQUAL AT P.T. MEMBERS2.SUBSTITUTION OF CONNECTORS SPECIFIED IN THIS DRAWING SET IS ALLOWED FOR EQUAL OR BETTER CONNECTOR PRODUCTSSTANDARD SHEATHING FASTENING - U.N.O.SPACINGTYPEMIN.LENGTHFLOOR SHEATHING (UNBLOCKED)23/32" CDX OR O.S.B. ORSTURDI - FLOOR T&G6" EDGE8" FIELD8d (.113)RING-SHANK2-3/8"FLOOR UNDERLAYMENT (GLUE AND STAGGER JOINTS)11/32" CCP8" EDGE8" FIELD#7 SCREWSSIDING(U.N.O.) (ALL EDGES SUPPORTED)15/32" T1-116" EDGE12" FIELDROOF SHEATHING (UNBLOCKED)7/16" O.S.B.6" EDGE8" FIELD15 GA. STAPLEMIN. 7/16" CROWN1-5/8"2"FROM ESR-1539 JULY 2018FASTENING/SCHEDULE8d (.113)GALVANIZED2-1/2"SIDING AT GRID '4' (ALL EDGES SUPPORTED)15/32" T1-114-1/2" EDGE8" FIELD8d (.113)GALVANIZED2-1/2"HARDWARE SCHEDULEGROUP #1HINGES:1-1/2 PAIR, MODERN STANDARDLEVERSET: (ENTRANCE)CORBIN RUSSWIN CL3351,NEWPORT 626, LFICSTRIKE: ANSICLOSER: LCN 1461WEATHER-STRIP: MODERN STANDARDDOOR SWEEP: MODERN STANDARDADA THRESHOLD: MODERN STANDARDDOORS: 1,2,3GROUP #2DOORS: 4GROUP #3DOORS: 5,8,9,10HINGES:1-1/2 PAIR, MODERN STANDARDLEVERSET: (PRIVACY)CORBIN RUSSWIN CL3340,NEWPORT 626STRIKE: FULL LIPDOOR STOP: MODERN STANDARDDOORS: 6,7HINGES:1-1/2 PAIR, MODERN STANDARDLEVERSET: (PASSAGE)CORBIN RUSSWIN CL3310,NEWPORT 626STRIKE: FULL LIPDOOR STOP: MODERN STANDARDGROUP #4HINGES:1-1/2 PAIR, MODERN STANDARDLEVERSET: (STOREROOM)CORBIN RUSSWIN CL357,NEWPORT 626, LFICSTRIKE: FULL LIPDOOR STOP: MODERN STANDARDSIDINGSTUDSINT. FINISHDOOR FRAME(6-3/4" THROAT)SIDINGINT. FINISHHEADERJAMBHEADDOOR FRAME(6-3/4" THROAT)PAN FLASHING& FLASHINGTHRESHOLD SETIN SEALANTDOOR FRAME(6-3/4" THROAT)THRESHOLD'Z' METALP.T. 2 x 8 RIMSIDINGWINDOW TRIMSTUDSINT. FINISHWINDOW TRIMSIDINGWINDOWINT. FINISHHEADERJAMBHEADSILLWINDOWSILLINT. FINISHWINDOWWINDOW TRIMSIDINGWINDOW SURROUNDWINDOWSURROUNDWINDOWSURROUND'Z' METALKENNETHA.RASMU S S E NSTATEOFWASHINGTON 21543REGISTEREDP R O FESSIONALENGINEERJOB#SHEET #DATESHEETPROJ.ADDRESSREUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION.DRWTELEPHONE: (503) 749-4949 FAX: (503) 749-4950P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com MODERN BUILDING SYSTEMS, INC. 2019MODERN BUILDING SYSTEMS, INC.© 2019-DH-50A 3.05/30/19 PRELIM.FINISH NOTES AND DETAILS401 COATES AVE. NW, YELM, WA 98597YELM SD VIIITS42' x 68' MODULAR OFFICEWINDOW SCHEDULEMark Count Width Height Type Frame Glass SHGC U-VAL Air Leakage Ext. Trim Int. Trim Window Header CommentsA 1 6' - 0" 4' - 0" XO VINYL DUAL / LOW E / TMP 0.30 0.34 .18 CFM/SF 1 x 4 HF (2) 2 x 8 DF #2 HORIZ. MINI-BLINDSB 7 6' - 0" 4' - 0" XO VINYL DUAL / LOW E 0.30 0.34 .18 CFM/SF 1 x 4 HF (2) 2 x 8 DF #2 HORIZ. MINI-BLINDSC 3 6' - 0" 2' - 0" XO VINYL DUAL / LOW E 0.30 0.34 .18 CFM/SF 1 x 4 HF (2) 2 x 8 DF #2 HORIZ. MINI-BLINDSNOTES:1.CAULK AND SEAL ALL EXTERIOR DOORS2.ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT (U.N.O.)3.ALL DOOR LEADS 4-1/2" (U.N.O.)4.ALL DOORS TO HAVE A OPENING FORCE NOT EXCEED 5 POUNDS5.DOOR SURFCES WITHIN 10" OF THE FLOOR MEASURED VERTICALLY, SHALL BE SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR PER SECT. A117.1 404.2.9NOTES:1.CAULK AND SEAL ALL EXTERIOR WINDOWSWALL SCHEDULEDESCRIPTION LENGTHEXTERIOR 2x6217' - 9"EXTERIOR 2x, SKIRTWALL 219' - 4"INTERIOR 2x4214' - 10"INTERIOR 2x636' - 9"ROOF SCHEDULEDESCRIPTION AREAROOFING 3241 SFAREA SCHEDULE (Gross Building)AREA TYPE AREAGross Building Area 2839 SFDOOR SCHEDULEMark Width Height Thickness Door Swing Core Lite Size Lite Glass Face Door Finish Frame Type Frame Finish Throat R.O. Type Hdw Group Fire Rating Door Header U-Value Remarks1 3' - 0" 6' - 8" 1 3/4" RHOS HM / INSUL NRW CLR / TMP MTL PT HM / PD PT 6 3/4" A 1 - (2) 2 x 8 DF #2 .222 3' - 0" 6' - 8" 1 3/4" RHOS HM / INSUL NRW CLR / TMP MTL PT HM / PD PT 6 3/4" A 1 - (2) 2 x 8 DF #2 .223 3' - 0" 6' - 8" 1 3/4" LHOS HM / INSUL NRW CLR / TMP MTL PT HM / PD PT 6 3/4" A 1 - (2) 2 x 8 DF #2 .224 3' - 0" 6' - 8" 1 3/4" LH SC - - BRCH PF HF PF 4 3/4" 1 2 - - -5 3' - 0" 6' - 8" 1 3/4" LH SC - - BRCH PF HF PF 4 3/4" 1 3 - - -6 3' - 0" 6' - 8" 1 3/4" LH SC - - BRCH PF HF PF 4 3/4" 1 4 - - -7 3' - 0" 6' - 8" 1 3/4" LH SC - - BRCH PF HF PF 4 3/4" 1 4 - - -8 3' - 0" 6' - 8" 1 3/4" RH SC - - BRCH PF HF PF 4 3/4" 1 3 - - -9 3' - 0" 6' - 8" 1 3/4" LH SC - - BRCH PF HF PF 4 3/4" 1 3 - - -10 3' - 0" 6' - 8" 1 3/4" LH SC - - BRCH PF HF PF 4 3/4" 1 3 - - - 1 1/2" = 1'-0"1EXTERIOR DOOR DETAILS 1 1/2" = 1'-0"2WINDOW DETAILSREV. DESCRIPTIONDATE BY INTERIOR ELEVATION NOTES1. DIMENSIONS TO FLOOR, WALLS ANDCEILING ARE TO FACE OF FINISH (U.N.O.)2. PROVIDE WOOD BLOCKING FOR ALLACCESSORIES MOUNTED IN GYPSUMBOARD PARTITIONS. MAINTAIN INTEGRITYOF FIRE RATING WHERE ACCESSORIES AREIN RATED WALLS.PAPER TOWELDISPENSERSURFACE-MOUNTEDMIRRORSURFACE-MOUNTEDTOILET SEATCOVERDISPENSERSURFACEMOUNTEDSOAPDISPENSERRESTROOMDOOR HOOKAEFGHTOILET PAPER HOLDERSIDE & VERTICAL GRAB BARBACK GRAB BARBCCDSCHEDULE OF ACCESSORIESI.D.ITEMSAPAPER TOWEL DISPENSER (N.I.C.)BTOILET TISSUE DISPENSERCHORIZONTAL GRAB BARDVERTICAL GRAB BARESOAP DISPENSER (N.I.C.)FMIRRORGTOILET SEAT COVER DISPENSER (N.I.C.)HHOOK (N.I.C.)ISHOWER SEAT (N.I.C.)BACK GRAB BAR/SEATSIDE GRAB BARC CDI1 1/4" TO2" NOM.DIAMETERWALLGRAB BAR SECTIONPLAN VIEWNOTE:1.DIMENSIONS TO FLOOR AND WALLS ARE TO FACE OF FINISH (U.N.O.)2.NOT ALL ACCESSORIES MAY BE PRESENT IN THIS PARTICULAR BUILDING.TO REFLECTIVESURFACECONTROLSMIN.18"1 1/2" MIN.42" MAX.MIN.24"33"-36"MIN.18"39"-41"12"MIN.42"39"-41"54" MIN.33"-36"MIN.12"MIN.24"36" MIN.SEAT17"-19"3' - 4"3' - 4" MAX.ADA STALL3' - 4" MAX.3' - 4"5'-0" REGULAR4' - 0" MAX. ADAMIN.15"MIN.17"19" MAX.30" MIN.48" MIN.*NOTE: IF A MINIMUM 9 INCHES HEIGHTOF TOE CLEARANCE IS PROVIDED, AMAXIMUM OF 6 INCHES OF THE 48INCHES OF CLEAR FLOOR SPACEREQUIRED AT THE FIXTURE MAYEXTEND INTO THE TOE SPACE.KNEE CLEARANCETOE CLEARANCE*SIDE VIEWLAVATORY KNEE CLEARANCE27" MIN.MIN.9"34" MAX.6" MAX.8" MIN.MIN.17"33"-36"18"4" MAX.3"-6"MIN.18"15" MAX.38" MIN.48" MAX.1 1/2"17"-19"REFRIG.(BYOTHERS)3' - 0"3' - 0"3' - 0"2' - 6"1' - 8"2' - 10"3' - 0"3' - 0"3' - 0"5' - 6"23/32" PLYWD. SHELFWATER HEATER2 x 4 FRAMING ALL AROUND4'-0" HIGH FRP WAINSCOTOVER WATER RESISTANTGYPSUM BOARD, ALL THREESIDES OF MOP SINKMOP SINK4' - 9" MIN.T.P. DISP.GRAB BARS4'-0" HIGH FRP WAINSCOTOVER WATER RESISTANTGYPSUM BOARD - TYP.1' - 6"5' - 8 1/2"1' - 3"4' - 4" MIN.MAX.2' - 9"PROVIDE PROTECTIVEINSUL. AT WATER SUPPLYAND DRAINPIPES18" x 36" MIRROR3' - 0"3' - 0"3' - 0"2' - 6"1' - 8"2' - 10"3' - 0"3' - 0"3' - 0"2' - 4"SPOUT HT.36" MAX.SPOUT HT.38" - 43"DRINKING FOUNTAINW/ BOTTLE FILLER(BY OTHERS). KENNETHA.RASMU S S E NSTATEOFWASHINGTON 21543REGISTEREDP R O FESSIONALENGINEERJOB#SHEET #DATESHEETPROJ.ADDRESSREUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION.DRWTELEPHONE: (503) 749-4949 FAX: (503) 749-4950P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com MODERN BUILDING SYSTEMS, INC. 2019MODERN BUILDING SYSTEMS, INC.© 2019-DH-50A 4.05/30/19 PRELIM.INTERIOR ELEVATIONS401 COATES AVE. NW, YELM, WA 98597YELM SD VIIITS42' x 68' MODULAR OFFICE 3/8" = 1'-0"6ADA MOUNTING HEIGHTS 1/4" = 1'-0"1BREAK ROOM - NORTH 1/4" = 1'-0"2JANITOR - SOUTH 1/4" = 1'-0"3TYP. RESTROOM - WEST 1/4" = 1'-0"4TYP. RESTROOM - NORTH 1/4" = 1'-0"5OPEN OFFICE - SOUTHREV. DESCRIPTIONDATE BY ELECTRICAL NOTES1.CONDUIT SHALL BE ELECTRICAL METALLIC TUBING AND METAL CLAD CABLE2.EXTERIOR RECEPTACLES SHALL BE WEATHER RESISTANT TYPE W/ IN USE WEATHERPROOF COVER3.FLUORESCENT LUMINAIRES WITH DOUBLE ENDED LAMPS THAT CAN BE SERVICED IN PLACE AND SHALL HAVE AN INTERNAL OR EXTERNAL DISCONNECT PER NEC 410.130G4.BUILDING SERVICE SHALL BE SERVED BY ONLY ONE SERVICE OR FEEDER PER NEC 225.30 AND 230.25.SERVICE OR FEEDER DISCONNECT SHALL BE INSTALLED PER NEC 230.70. FOR BUILDINGS IN THE STATE OF WASHINGTON SERVICE OR FEEDER DISCONNECT SHALL BE INSTALLED PER WAC 296-46B-2306.PERMANENT MEANS OF LOCKING OUT DISCONNECT TO MECHANICAL UNIT(S) SHALL BE PROVIDED PER NEC 424.197.PERMANENT MEANS OF LOCKING OUT DISCONNECT TO WATER HEATER(S) SHALL BE PROVIDED PER NEC 422.31(B)8.GASKET ALL EXTERIOR WALL BOX PLATE COVERS9.PER NEC 110.26D, ILLUMINATION FOR PANEL BOARDS, SWITCH-BOARDS, AND SERVICE EQUIPMENT SHALL NOT BE CONTROLLED BY AUTOMATIC MEANS ONLY. A MANUAL MEANS TO BYPASS THE AUTOMATIC CONTROL IS REQUIRED.10. PER NEC 406.9(B)(1) 15 AND 20 AMP RECEPTACLES INSTALLED IN WET LOCATION SHALL HAVE AN ENCLOSURE THAT WEATHER-PROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. AN OUTLET BOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND SHALL BE IDENTIFIED AS EXTRA DUTY". RECEPTACLES SHALL BE LISTED AS WEATHER-RESISTANT TYPE.11. PER NEC 110.26, WORKING SPACE FOR EQUIPMENT OPERATING AT 600 VOLTS, NOMINAL, OR LESS TO GROUND AND LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED SHALL COMPLY WITH THE DIMENSIONS OF 110.26(A)(1), (A)(2), AND (A)(3)12. PER NFPA 72, NEC 760 AND WAC 296-46B-760 DEVICE AND JUNCTION BOXES FOR FIRE ALARM SYSTEMS OTHER THAN SURFACE RACEWAY TYPE MUST BE SUBSTANTIALLY RED IN COLOR BOTH INSIDE ANDOUTSIDE. POWER LIMITED FIRE PROTECTIVE SIGNALING CIRCUIT CONDUCTORS MUST BE DURABLY AND PLAINLY MARKED IN OR ON JUNCTION BOXES OR OTHER ENCLOSURES TO INDICATE THAT IT IS POWER LIMITED FIRE PROTECTIVE SIGNALING CIRCUIT.13. PER NEC 110.22 AND WAC 296-46B-220-032 IDENTIFICATION PLATES ON DISCONNECTING MEANS ARE TO SHOW DESIGNATION OF CIRCUIT SOURCE PANEL BOARD THAT SUPPLIES DISCONNECT AND IDENTIFY WHAT IT IS DISCONNECTING. MUST BE AN IDENTIFICATION PLATE14. PER NEC 406.3E, ALL NONLOCKING TYPE, 125 VA, 15 AMP, AND 20 AMP RECEPTACLES THAT ARE CONTROLLED BY AN AUTOMATIC CONTROL DEVICE, OR THAT INCORPORATE CONTROL FEATURES THAT REMOVE POWER FROM THE OULET FOR THE PURPOSE OF ENERGY MANAGEMENT OR BUILDING AUTOMATION, SHALL BE MARKED WITH THE SYMBOL SHOWN IN FIGURE 406.3E AND LOCATED ON THE CONTROLLED RECEPTACLE OUTLET WHERE VISIBLE AFTER INSTALLATION200 AMPMAIN BREAKER120/208VTHREE PH.W/ PVCSTUB-OUTONE-LINE DIAGRAMNO SCALE(BY MODERN)200 AMPSERVICEDISCONNECT120/208VTHREE PH.#4 CU BARE UFERGROUND ON SITESERVICE (3) 3/0 THWN +(1) #4 THWN2" PVC CONDUIT(BY OTHERS)1.EMT CONDUIT SHALL NOT BE USED WITH UNFUSED CONDUCTORS INSIDE BUILDING LINES2.FIELD VERIFY AIC RATING REQUIREMENTS3.BUILDING / SERVICE DISCONNECTING MEANS MUST BE LOCATED ON OR WITHIN 15 FEET OF THE BUILDING AND MUST HAVE LABEL IDENTIFYING IT'S FUNCTION AS THE BUILDING DISCONNECT PER WAC 296-46B-2254.GROUNDING TO BE IN ACCORDANCE TO NEC 2505.SITE INSTALLED PORTION OF ELECTRICAL DISTRIBUTION SYSTEM DESIGN IS GENERIC. SUBJECT TO APPROVAL OF ELECTRICAL LOCAL AUTHORITY HAVING JURISDICTION PLAN REVIEW AND/OR INSPECTION OF SITE INSTALLED ELECTRICAL DISTRIBUTION SYSTEM(BY OTHERS)SEE NOTE #5ABOVEONE-LINE DIAGRAM NOTESKENNETHA.RASMU S S E NSTATEOFWASHINGTON 21543REGISTEREDP R O FESSIONALENGINEERJOB#SHEET #DATESHEETPROJ.ADDRESSREUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION.DRWTELEPHONE: (503) 749-4949 FAX: (503) 749-4950P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com MODERN BUILDING SYSTEMS, INC. 2019MODERN BUILDING SYSTEMS, INC.© 2019-DH-50E 0.15/30/19 PRELIM.ELEC. PANELS & LOAD CALCS.401 COATES AVE. NW, YELM, WA 98597YELM SD VIIITS42' x 68' MODULAR OFFICETOTAL AMPS = 83 A TOTAL AMPS = 83 ATOTAL VA = 29877 VA TOTAL VA = 30399 VACONNECTED LOADCALCULATED LOADREFRIGERATOR 1000 VA 100.00% 1000 WDRINKING FOUNTAIN 500 VA 100.00% 500 WPRINTER/COPIER 1000 VA 100.00% 1000 WWATER HEATER 4500 VA 100.00% 4500 WMISCELLANEOUS14800 VA 100.00% 14800 WTOTAL HEAT & A/C LOADHEATING & A/C (Per Mfg's Specs)LARGEST MOTOR 8 VA 25.00% 2 VAEXHAUST FAN 16 VA 100.00% 16 WMOTORS & COMPRESSORSDED. RECEPTACLE0 WRECEPTACLE 5940 VA 100.00% 5940 WSIGN CIRCUIT 1200 VA 125.00% 1500 WLIGHTS 913 VA 125.00% 1141 WITEM CONNECTED LOAD DEMAND FACTOR CALCULATED LOADMAIN BREAKER 200 APHASE 3BUSS SIZEVOLTAGE 120/208 WyeTOTAL PANEL VA=29869 VA83 A=TOTAL PANEL AMPS9863 VA 10102 VA 9904 VAA29A30A27A28Printer Receptacle 20 A A25 1 180 VAA26Printer/Copier 20 A A23 11000... 1000... 1 A24 20 A Refrigerator (GFCI)A21180 VA 1 A22 20 A Printer ReceptacleERV-2 20 A A19 1 180 VA 120 VA1 A20 20 A ERV-1Receptacles 20 A A17 1540 VA 500 VA 1 A18 20 A Drinking FountainReceptacles 20 A A15 1 1260... 2250... -- A16 -- --Receptacles 20 A A13 1 1080... 2250...2 A14 20 A Water HeaterReceptacles 20 A A11 1900 VA 2486... -- A12 -- --Receptacles 20 A A9 1 1080... 2486... 2 A10 25 A OU-2CERV Service Receptacles 20 A A7 1 360 VA 2278...-- A8 -- --Sign Circuit 20 A A5 11200... 2278... 2 A6 25 A OU-2BExterior Receptacles 20 A A3 1 360 VA 2486... -- A4 -- --Lighting / Exhaust Fans 20 A A1 1 929 VA 2486...2 A2 25 A OU-1ALoad Name RatingCircuitNumberNumberof PolesA B CNumberof PolesCircuitNumberRating Load NameMOUNTINGRecessedDATE:5/30/19 PRELIM.MAIN DISTRIBUTION PANELPANEL APROJECT NO:2019-DH-50REV. DESCRIPTIONDATE BY JJJGFCIGFCIGFCIGFCICRCRCR CR CRCR CRCRCRCRCRCRCRCRCRCRCRCRCRCR CRCRCRCRCRCRJJJCCCLCLCLCLC LCLCLC33OS OSOS14AFBCDEMOD AMOD BMOD CBREAKROOMOPEN OFFICEOFFICE #1OFFICE #2OFFICE #3WORK ROOMOFFICE #4OFFICE #5RESTROOM#1RESTROOM#2PRINTERPRINTERPRINTER/COPIERPPPPPPPPPPPPPPCAT5 TOLIGHTING OSCAT5 TOLIGHTING OSCAT5 TOLIGHTING OSCAT5 TOLIGHTING OSCAT5 TOLIGHTING OSCAT5 TOLIGHTING OS+42"+48"+42"+42"+42"CAT5 TOLIGHTING OSPPCAT5 TOLIGHTING OSSIGN CIRCUIT ABV. CEILINGTYP. AT EXTERIOR DOORS20 GAL. WHREFRIG.(BYOTHERS)PANEL A120/208V / 200ATHREE PHASEJAN.A5A5A5A17A17A17A9A9A9A9A9A9A11A11A11A11A11A13A13A13A13A13A13A15A15A15A15A15A15A15GFCI/WP/WRGFCI/WP/WROU-1AOU-2BOU-1CA2,4A6,8A10,12A14,16A20A19A3A3A7A7A23A24A18ABV. CEILINGFOR ERV-1ABV. CEILINGFOR ERV-123HALLWAY+84"OU-1COU-1AOU-2BERV-2ERV-1A25A2214AFBCDEMOD AMOD BMOD CBREAKROOMOPEN OFFICEOFFICE #1OFFICE #2OFFICE #3WORK ROOMOFFICE #4OFFICE #5RESTROOM#1RESTROOM#2JAN.OSOSOSOSDL-POSDL-POSDL-POSDL-POSDL-POSDL-POSDL-POSDL-POSDL-PDL-PDL-PDL-PDL-PDL-PWP/PCWP/PCWP/PCA1A1A1A1A1EF-1A1EF-1A1A1 A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A123HALLWAYDAYLIGHTPRIMARYZONE - TYP.DAYLIGHTSECONDARYZONE - TYP.ELECTRICAL SYMBOLS LEGENDDUPLEX RECEPTACLE +17" A.F.F. (U.N.O.)GFCI = GROUND FAULT CIRCUIT INTERRUPTERWP = IN USE WEATHERPROOF COVERWR = WATER RESISTANT RECEPTACLEJUNCTION BOXINDOOR UNIT CONTROLLERPHONE/DATA BOX - 3/4" CONDUIT UP (RACEWAY ONLY) DISCONNECTJCCONTROLLED RECEPTACLE POWER PACKCRCONTROLLED DUPLEX RECEPTACLE 50% OF RECEPTACLE CONTROLLED BY SENSOR AND VISIBLY DIFFERENTIATED PER WSEC 405.10TR = TAMPER RESISTANTPPSYMBOLDESCRIPTIONHEIGHT ℄ (U.N.O)+17"--+48" TOP-+17"+17"ERV WALL SWITCH+48" TOPERVLIGHTING SYMBOLS LEGENDOCCUPANCY SWITCH SENSOR: - W/ MANUAL ONOS2' x 4' LED LAY-IN FIXTURE - CONTINUOUS DIMINGDL-P = DAYLIGHT ZONE - PRIMARYDL-S = DAYLIGHT ZONE - SECONDARY13" LED SURFACE MOUNT FIXTURE2' x 4' LED LAY-IN FIXTURE W/ INTEGRAL nLIGHT DAYLIGHT AND OCCUPANCY SENSORSOSDLEXTERIOR LED WALL MOUNT LIGHT FIXTURE PC = PHOTOCELLWP = WEATHERPROOFLIGHTING CONTROL WALL SWITCHLCSYMBOLDESCRIPTIONHEIGHT ℄ (U.N.O)CEILINGCEILINGCEILING+92"+48" TOP+48" TOPOFFICE, BREAK34 WATT x (23) = 782 WATTSRESTROOMS, JAN.28 WATT x (3) = 84 WATTSELECTRICAL LIGHTING SUMMARYTOTAL INTERIOR INPUT WATTS = 866 WATTS EXTERIOR LIGHTING17 WATT x (3) = 51 WATTSTOTAL EXTERIOR INPUT WATTS = 51 WATTS CONTINUOUS DIMMING PER WSEC C406.4(782/866 = 90%) = NOT LESS THAN 90%REDUCED LIGHTING POWER DENSITY MEETS WSEC C406.3(838) WATTS ≤ (1405) WATTS = (75%) x (0.66 WATT/FT2) x 2839/FT2)1. THIS BUILDING PROVIDES LIGHTING "ADDITIONAL EFFICIENCY PACKAGE OPTIONS" PER C406.3 AND C406.4, TOINCLUDE WAC 51-11C, SECTION C406.4 #2, EXCEPTION #32.LIGHT LEVELS TO MEET WAC 246-366-115 TABLE 23.OCCUPANCY SENSOR(S) IN EACH ROOM WILL BE WIRED TO CONTROL ALL LIGHT FIXTURES IN THAT ROOM.4.LIGHT WIRING AS SHOWN IS FOR GENERAL CONTROL CLARIFICATION ONLY. ACTUAL WIRING FOR CONTROLS (I.E.: SWITCHES, OCCUPANCY SENSORS AND DAYLIGHT SENSORS) SHALL BE PER CONTROL MANUFACTURER'S SPECIFICATIONS AND AS NECESSARY TO MEET THE CODE REQUIREMENTS FOR EACH CONTROL AND THE LIGHT FIXTURES CONNECTED TO IT.5.DAYLIGHTING AND OCCUPANCY SENSORS ARE INTEGRAL TO EACH LIGHT FIXTURE AS SHOWN AND PROGRAMMED TO COVER EACH DAYLIGHT ZONE. OCCUPANCY SENSORS ARE PROGRAMMED TO CONTROL ALL FIXTURES IN THE SPACELIGHTING PLAN NOTES120V POWERCAT5 CABLELIGHT FIXTURE WIRING LEGENDKENNETHA.RASMU S S E NSTATEOFWASHINGTON 21543REGISTEREDP R O FESSIONALENGINEERJOB#SHEET #DATESHEETPROJ.ADDRESSREUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION.DRWTELEPHONE: (503) 749-4949 FAX: (503) 749-4950P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com MODERN BUILDING SYSTEMS, INC. 2019MODERN BUILDING SYSTEMS, INC.© 2019-DH-50E 1.05/30/19 PRELIM.ELEC. POWER & LIGHTING PLANS401 COATES AVE. NW, YELM, WA 98597YELM SD VIIITS42' x 68' MODULAR OFFICE 3/16" = 1'-0"1ELECTRICAL PLAN 3/16" = 1'-0"2LIGHTING PLANREV. DESCRIPTIONDATE BY CCC14AFBCDEMOD AMOD BMOD CBREAKROOMOPEN OFFICEOFFICE #1RESTROOM#1RESTROOM#2OFFICE #5OFFICE #4WORK ROOMOFFICE #3OFFICE #2JAN.OU-1AOU-2BOU-1CERV-1ERV-2EF-1EF-1IU-2A2IU-2A3IU-2A4IU-2B3IU-1A1IU-2B1IU-2B2IU-2C1IU-2C2IU-2C3IU-2C430" MIN.SERVICEACCESS40 CFM4"ø40 CFM4"ø80 CFM6"ø80 CFM6"ø6"øR/A80 CFM6"ø80 CFM6"ø6"øF/A6"øE/A4"øEA6"øE/A6"øR/A6"øS/A3'-0" MIN.11122222222222234"øO/A4"øE/A3HALLWAY6"øE/A6"øO/AOU-1COU-1AOU-2BERV-2ERV-145555MECHANICAL NOTES1.CONTROLS:OU-1 & OU-2: DAIKIN BRC1E73 - WIRE REMOTE CONTROLLERERV1:CONTROLLED INTERNALLY, WALL SWITCH ENABLE/DISABLEERV-2: CONTROLLED INTERNALLY, WALL SWITCHENABLE/DISABLE2.DUCTWORK:MATERIAL:1" FIBERGLASS (R-4.3) OR 24 GA. SHEET METAL W/ 26 GA. SHEET METAL ROUNDS AND FLEX DUCT ROUNDS AT DIFFUSERSINSULATING AND SEALING:DUCTWORK TO BE INSULATED AND SEALED PER WSEC C403.2.8.1 AND C403.2.8.2CONSTRUCTION:DUCTWORK TO BE CONSTRUCTED ASLOW PRESSURE DUCT SYSTEM PERWSEC C403.2.8.3.13.VOLUME DAMPERS:PROVIDE VOLUME DAMPERS TO CONTROL AIRFLOW AT EACH TAKE-OFF4.DESIGN: MECHANICAL EQUIPMENT TO MEET NC-35NOISE CRITERION AND MECHANICAL BACKGROUNDNOISE AT OR BELOW 45 DBA.LOCATE BUILDINGS AWAY FROM NOISE AND POLLUTION SOURCES5.ERV: (DOAS) PER WSEC C403.6ERV-1: SET SUPPLY & RETURN AT 100 CFMTIME ON = 60 MIN. PER HOURERV-2: WALL SWITCH PROVIDES 100% AIRCAPACITYERV3/8" DIA. THREADEDROD W/ WASHER & NUT - TYP.3/8" VERTICAL THREADED ROD FASTENER, MIN. EMBED 2" (ALLOWABLE TENSION LOAD 322# EA.)12-1/2 GA. WIRE EA.SIDE BOTHDIRECTION - TYP.11+/-RAFTERERV3/8" DIA. THREADEDROD W/ WASHER & NUT - TYP.3/8" VERTICAL THREADED ROD FASTENER, MIN. EMBED 2" (ALLOWABLE TENSION LOAD 322# EA.)RAFTERS3/8" STRUT NUT W/ 3/8" FLAT WASHER -TYP. 3/8" NUT W/LOCK WASHER-TYP.1-13/16" CHANNEL STRUT AS REQ'D - TYP.11+/-12-1/2 GA. WIRE EA.SIDE BOTHDIRECTION - TYP.HVAC SYMBOLS LEGENDSYMBOLDESCRIPTIONHEIGHT ℄ (U.N.O)CEILING+48" TOPLAY-IN SUPPLY DIFFUSER, SEE PLAN FOR SIZELAY-IN RETURN GRILLE, SEE PLAN FOR SIZEFLEX DUCTINDOOR UNIT CONTROLLERERV WALL SWITCHCEILING-+48" TOPERVCHVAC PLAN KEYNOTESRUN REFRIGERANT LINES TO INDOOR UNITS IN EXTERIOR WALLS AND ABOVE CEILING PER MANUFACTURER'S INSTRUCTIONSGRAVITY DRAIN CONDENSATE TO EXTERIORMIN. 30" SERVICE CLEARANCE UNDER ERV.COORDINATE WITH CEILING GRID PLACMENT TO PROVIDE REQUIRED ACCESS SPACE.PANASONIC WALL CAP FV-WC04VE1 FOR SINGLE O/A & E/A WALL PENETRATIONMOTORIZED DAMPERS AT O/A AND E/A.FAMCO ADC6120 AND ADC4120 OR EQUAL12345RAFTERDUCT24 GA. DRIVE CLEATAT 6'-0" O.C., EA. SIDE11BELLYSTRAPKENNETHA.RASMU S S E NSTATEOFWASHINGTON 21543REGISTEREDP R O FESSIONALENGINEERJOB#SHEET #DATESHEETPROJ.ADDRESSREUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION.DRWTELEPHONE: (503) 749-4949 FAX: (503) 749-4950P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com MODERN BUILDING SYSTEMS, INC. 2019MODERN BUILDING SYSTEMS, INC.© 2019-DH-50M 1.05/30/19 PRELIM.HVAC PLAN AND NOTES401 COATES AVE. NW, YELM, WA 98597YELM SD VIIITS42' x 68' MODULAR OFFICE 1/4" = 1'-0"1HVAC PLANHVAC EQUIPMENT SCHEDULEMark Count Description Manufacturer ModelHeatingEfficiencyCoolingEfficiencyWeight (LBS)HeatingCapacity(Btu/h)CoolingCapacity(Btu/h)CFM MCA MOP Volts Phase NotesOU-1 2 4 PORT, 3-TON OUTDOOR HEAT PUMP DAIKIN 4MXS36RMVJU HSPF = 12.2 SEER = 17.7 139 36,000 36,000 - 23.9 25 208 1OU-2 1 3 PORT, 2-TON OUTDOOR HEAT PUMP DAIKIN 3MXS24RMVJU HSPF = 12.5 SEER = 18 137 24,000 24,000 - 21.9 25 208 1IU-1 1 1.25-TON CEILING MOUNTED INDOOR UNIT DAIKIN FFQ15Q2VJU - - 36 15,000 15,000 - - - -IU-2 10 .75-TON CEILING MOUNTED INDOOR UNIT DAIKIN FFQ09Q2VJU - - 36 9,000 9,000 - - - -ERV-1 1 ENERGY RECOVERY VENTILATOR PANASONIC FV-10VE1 - -48 - - 100 1 15 120 1 MARK WALL SWITCH AS 'ERV-1"ERV-2 1 ENERGY RECOVERY VENTILATOR SOLER & PALAU TR200 -- 70 - - 200 1.5 15 120 1 MARK WALL SWITCH AS 'ERV-2"EF-1 2 EXHAUST FANPANASONIC FV-0510VS1 - - 9 - - 80 .39 20 120 1 MOTORIZED DAMPER: FAMCO ADC4120NATURAL VENTILATION SUMMARYName Area4% Of Floor Area(Required)Window Clr. Opening(Provided)OFFICE #1 158 SF 6.34 SF 10.35 SFOFFICE #2 145 SF 5.80 SF 10.35 SFOFFICE #3 184 SF 7.35 SF 20.7 SFOFFICE #4 188 SF 7.54 SF 10.35 SFOFFICE #5 194 SF 7.76 SF 20.7 SFOUTSIDE AIR CALCULATIONName AreaOcc. Density(#/1000 FT2)People AirflowRate(CFM/Person)Area OutdoorAirflow Rate(CFM/FT2)Exhaust AirflowRate(CFM/FT2)Qty.FlushFixt.Occ.LoadOcc. Airflow(CFM)Area Airflow(CFM)ExhaustAirflow(CFM)BREAK ROOM 238 SF 50 5 0.06 0 0 12 60 14 0HALLWAY 153 SF0 0 0 0JAN. 35 SF 0 0 0 0 0 0 0 0 0OFFICE #1 158 SF 5 5 0.06 0 0 1 5 10 0OFFICE #2 145 SF 5 5 0.06 0 0 1 5 9 0OFFICE #3 184 SF 5 5 0.06 0 0 1 5 11 0OFFICE #4 188 SF 5 5 0.06 0 0 1 5 11 0OFFICE #5 194 SF 5 5 0.06 0 0 1 5 12 0OPEN OFFICE 1026 SF 5 5 0.06 0 0 6 30 62 0RESTROOM #1 59 SF 0 0 0 70 1 0 0 0 70RESTROOM #2 59 SF 0 0 0 70 1 0 0 0 70WORK ROOM 350 SF 5 5 0.06 0 0 2 10 21 025 125 149 140 3/4" = 1'-0"2ERV MOUNTING 3/4" = 1'-0"3ERV MOUNTING - ALTERNATE 1" = 1'-0"4DUCT SUPPORTREV. DESCRIPTIONDATE BY