Performance Systems Integration LLC
Fire Alarm Submittal Guide Prestige Care Rosemont 215 Killion Road SE Yelm, WA 98597 Scope of work: Replace existing fire alarm control panel. All field devices are compatible and will remain. Prepared By: 19310 North Creek Pkwy #109 Bothell, WA 98011 Phone: 425-368-4201 Fax: 425-368-4208 5/10/2019 Fire Alarm Project Material List Prestige Care Rosemont 215 Killion Road SE Yelm, WA 98597 Part Number Description SLC95-PM APOLLO SLC PERONALITY MODULE DACT-E3 DIGITAL ALARM COMMUNICATOR TRANSMITTER LCD-SLP LCD TOUCHSCREEN DISPLAY UNIT A2 E3 GAMEWELL-FCI E3 FIRE ALARM CONTROL PANEL 19310 North Creek Pkwy #109 Bothell, WA 98011 Phone: 425-368-4201 Fax: 425-368-4208 5/10/19 DACT-E3 DACT-E3 Digital Alarm Communicator Transmitter Analog and Networking Systems General The Digital Alarm Communicator Transmitter (DACT-E3) is a digital communications circuit. It is an optional component of the following systems. • E3 Series® Expandable Emergency Evacuation System • S3 Series Small Addressable Fire Alarm Control Panel The DACT-E3 sends digital signals over the telephone network that transmits to a central station. This module can be located in the main cabinet or remotely located via a local RS-485 serial interface. The DACT-E3 is compatible with digital alarm communicator receivers (DACRs) that receive the following signaling formats: In addition to the DACT-E3 being compatible with digital signaling formats, the DACT- E3 features numerous formats for communication to a central station. As a digital communicator, the DACT-E3 complies with FCC Part 8, Telecommunication Standards for DC and AC Ringer Equivalence. Installation The DACT-E3 is adaptable for installation in the standard E3 Series and S3 Series System cabinets. Typically, the DACT-E3 module mounts on standoffs on top of the left side of the ILI-MB-E3/ILI95-MB-E3 or SLP (Smart Loop Panel) module. Either unit can be easily connected to the backbox or sub-assembly plate depending on the cabinet module. For instructions on how to install the DACT-E3, refer to the following documents: • E3 Series Expandable Emergency Evacuation Manual, P/N:LS10080-051GF-E • DACT-E3 Installation Instructions, P/N:9000-0581 • S3 Series (Small Addressable Fire Alarm Control Panel) UL Listing Document, P/N:LS10005-051GF-E Ordering Information DACT-E3: Digital Alarm Communicator Transmitter FEATURES & BENEFITS • Listed under UL®® Standard 864, 9th Edition • Transmits and verifies data to the central station • Communicates with the following sub- assemblies via the RS- 485: - E3 Series - ILI-MB-E3 - ILI95-MBE3 - S3 Series, SLP • Sends information in a variety of formats (including full Contact ID) • Offers pre- programmed dialing to the central station phone number • Performs on and off- hook status to the phone lines • Traces proper central station “ACK” and “Kiss-off” tone • Activates hang-up and release phone lines • Compatible with the IPDACT Internet Communicator • SIA DC8 • 3+1 2300 Hz • SIA DCS20 • 4+2 1400 Hz • Ademco Contact ID • 4+2 2300 Hz • 3+1 1400 Hz DACT-E3 Technical Specifications 9020-0610 | L | 09/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series® and Gamewell-FCI ® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s DACT-E3 and other products available by visiting www.Gamewell-FCI.com SYSTEM Operating Voltage: 24 VDC (from the PM-9/ PM-9G power supply) Operating Current: 0.018 amp Alarm Current: 0.018 amp Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 0 to 93%, non-condensing at 90° F (32° C) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for opera- tion at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme tem- perature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The DACT-E3 is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 FM Approved: 3025415 MEA Approved, Fire Dept. of New York: COA# 6077 CSFM: 7165-1703-0125 City of Chicago: Class 1, Class 2 and High Rise City of Denver E3 Series® Cabinets E3 Series® Cabinets Cabinets used for the E3 Series Analog and Networking Systems General The E3 Series® Expandable Emergency Evacuation System by Gamewell-FCI offers several cabinet size options. The E3 Series System is a modular design that allows a wide range of configurations to form an integrated, distributed fire alarm system. These cabinet options allow for sturdy and modern installations. The E3 Series cabinet assembly is a compact, wall-mounted enclosure. A typical cabinet includes a backbox and an outer locking door. In addition, there are several inner door options and mounting plates to accommodate a variety of E3 Series sub-assemblies. Each cabinet backbox includes mounting patterns for plates to allow the installer to arrange and secure the sub-assemblies to the backbox. The backbox knockouts are also positioned at numerous points to allow a conduit access into the enclosure. The following four Annunciator cabinet sizes provide the maximum flexibility that can meet any application. • Cabinet AA offers 2-slot or 3-slot options to accommodate any of the following configurations: – Inner door, 2-slots allows space for one LCD-E3 or LCD-SLP and one ASM-16 – Inner door, 3-slots allows space for any combination of three modules: ASM-16, NGA or an ANU-48 • Cabinet A1 houses one NGA or one ASM-16/ANU-48. • Cabinet A2 accommodates a single LCD-E3. • E3BB-FLUSH-LCD or E3BB-NGA-FLUSH. The E3BB-R-BSlim or B-Slim contains the 600 Series cabinet. Cabinet B includes a mounting plate that contains a space for the following modules: • ILI-MB-E3/ILI95-MB-E3 •PM-9/PM-9G sub-assemblies • Batteries set inside the backbox Additional sub-assembly options mounted on the backbox include the DACT-E3 and RPT-E3. The 2-slot inner door houses the following options: FEATURES & BENEFITS • IBC Seismic Certified • 16-gauge steel backbox •Contains removable outer and inner doors •Lexan® windows appear on the doors of most cabinets, except the Cabinet “C” and “D” INX cabinets and the INX CAB-B cabinet which contain louvered doors • Built with an inner door bonding strap used to provide electrical continuity for grounding • Cabinets are available in either black or red • Backbox and door ground studs provide positive grounding, and 180° opening door with full clearance • Offers 90° opening door with zero clearance • Includes a keylock with quarter turn latch •Trim Ring accessories available • one LCD-E3 module and• either one ASM-16/ANU-48 or one NGA module 2 General Both the C and D-size Command Center cabinets house a variety of E3 Series Broadband sub- assemblies that can be used in multiple configurations that provide a solution to a wide range of applications. Two flexible inner door panel selections are available for C and D-size Command Center cabinets that may contain any of the following: • fire fighter’s phone handset •microphone • optional modules to meet the facility operation requirements Refer to the Inner Door and Backbox Mounting Capacities in the Ordering Information Section. Ordering Information Inner Door Mounting Capacity Part Number Description Cabinet “AA” Size Dimensions:19 1/4” W x 10” H x 4 1/2” D (49 W x 25 H x 11.4 D cm) E3BB-BAA Enclosure, Black, “AA” (LOC) Size E3BB-RAA Enclosure, Red, “AA” (LOC) Size E31D2-TA Inner Door, 2-slots (INCC-TEL & ASM-16) E3ID2-A Inner Door, 2-slots (LCD-E3 or LCD-SLP & ASM-16) E3ID3-A Inner Door, 3-slots (NGA, ASM-16 and MIC) Cabinet “AA1” Size: Dimensions:8 3/4” W x 10” H x 4 1/2” D (22 W x 25 H x 11.4 D cm) E3BB-BAA1 Remote Enclosure, Black, w/Inner Door, 1 slot, (NGA) E3BB-RAA1 Remote Enclosure, Red, w/Inner Door, 1-slot, (NGA) Cabinet “A2” Size: Dimensions:13 1/4” W x 10” H x 4 1/2” D (40 W x 25 H x 11.4 D cm) E3BB-BA2 Remote Enclosure, Black, w/Inner Door, 1-slot, (LCD-E3 or LCD-SLP) E3BB-RA2 Remote Enclosure, Red, w/Inner Door, 1-slot, (LCD-E3 or LCD-SLP) Flush Cabinet A2 Annunciators: Dimensions:13 1/4” W x 10” H x 4 1/2” D (40 W x 25 H x 11.4 D cm) E3BB-FLUSH-LCD CAB A2 Remote Flush LCD ANN with Key switch operation E3BB-NGA-FLUSH CAB A2 Remote Flush NGA ANN with Password protected Cabinet “B-Slim” Size: (Retrofit Kits) Dimensions:14” W x 20” H x 4 1/2: D (35.5 W x 50.8 H x 11 D cm) E3BB-RBSLIM Assy, Enclosure, B-SLIM, Red with Backplate and LCD-E3 Keyswitch plate IF600-RETROFIT Door and Cab mounting plates, disable key switch and door lock (PK-625) for E3 Series upgrade. Cabinet “B” Size: Dimensions:19 3/8”W x 19 3/8”H x 4 1/2”D (49 W x 49 H x 11 D cm) E3BB-BB Assy, Backbox Enclosure, Black,“B” Size E3BB-RB Assy, Backbox Enclosure, Red, “B” Size E3ID2-B Inner Door, 2-slots, “B” Size 1100-0458 B Size INCC Command Center enclosure, black 1100-0459 B Size INCC Command Center enclosure, red door 1100-0460 INX-Transponder 19” (cm) Backbox with Door, Black Ordering Information (Continued) Part Number Description Cabinet “B” Size (Continued) Dimensions:19 3/8”W x 19 3/8”Hx4 1/2”D (49 W x 49 H x 11.43 D cm) Cabinet “C” Size: Dimensions:19 3/8” W x 30” H x 4 1/2” D (49 W x 76 H x 11 D cm) E3BB-BC/INCC Enclosure, Command Ctr, Black, “C” Size E3BB-RC/INCC Enclosure, Command Ctr, Red, “C” Size E3ID2-C Assy, Inner Door, Command Ctr.2- Bay “C” Size E3ID3-C Assy, Inner Door, Command Ctr, 3-Bay “C” Size E3BB-BC/INX Assy, Transponder, Black, “C” Size E3BB-RC/INX Assy, Transponder, Red, “C” Size E3-INCC-CPLATE Command Center module mounting plate, “C” Size E3-INX-CPLATE Transponder mounting plate, “C” Size Inner Door Mounting Capacity E3-ILI-CPLATE Intelligent loop module mounting plate “C” Size Cabinet “D” Size: Dimensions:19 3/8” W x 41” H x 4 1/2” D (49 W x 104 H x 11 D cm) E3BB-BD/INCC Enclosure, Command Ctr, Black, “D” Size E3BB-RD/INCC Enclosure, Command Center, Red, “D” Size E3ID2-D Assy, Inner Door, 2-Bay, “D” Size E3ID3-D Assy, Inner Door, 3-Bay, “D” Size E3BB-BD/INX Enclosure, Transponder, Black “D” Size E3BB-RD/INX Enclosure, Transponder, Red, “D” Size E3-INCC-D-PLATE Command Center module mounting plate, “D” Size E3-INX-D-PLATE Transponder module mounting plate, “D” Size Optional Extender Plates AM-50 Plate AM-50 Extender Plate FPT-GATE-3-EXT FPT-GATE-3 Extender Plate Optional Accessories 1100-0450 Command Center, blank plate, single size E3-BP Inner door panel, blank, double size 90375 PM-9/PM-9G Adapter Plate Kit,Hardware E3-TRIMKIT-A Trim kit for “A”/”AA” size enclosure, black E3-TRIMKIT-A1 Trim kit for “AA1” size enclosure, black E3-TRIMKIT-A2 Trim kit for “A2” size enclosure, black E3-TRIMKIT-B Trim kit for “B” size enclosure, black E3-TRIMKIT-C Trim kit for “C” size enclosure, black E3-TRIMKIT-D Trim kit for “D” size enclosure, black Bulk Amplification AA-100 100 W Audio Amp.@70.7 VRMS w/120 VAC AA-120 120 W Audio Amp. @25 VRMS w/ 120 VAC ACT-1 Audio coupling transformer, for audio systems w/multiple supplies FCI-CHG-120 Battery Charger, 25-120 A/H Gel cell FCI-LBB Battery box, accommodates batteries up to 55 A/H, (Black) Cabinet C: FCI-DR-C4B Large Battery Backbox,blank door,lock and keys for backbox accepting 3 chassis, (Black) FCI-DR-C4BR Blank door, lock and keys, for backbox accepting 3 chassis, (Red) SBB-C4 Backbox, 3 chassis, (Black) Cabinet D: FCI-DR-D4B Blank door, lock and keys, for backbox accepting 4 chassis, (Black) FCI-DR-D4BR Blank door, lock and keys, for backbox accepting 4 chassis, (Red) SBB-D4 Backbox, 4 chassis, (Black) 90516 7100-Slim 7A/H Seismic Battery Bracket Kit Seismic Battery Bracket Kits Part Number Description E3 B-Slim 7 A/H Seismic Battery Bracket Kit 90517 7100-Slim 12 A/H Seismic Battery Bracket Kit E3 B-Slim 12 A/H Seismic Battery Bracket Kit 90518 E3 CAB-B 7 A/H Seismic Battery Bracket Kit 3 Ordering Information (Continued) Seismic Battery Bracket Kits (Continued) Part Number Description E3 CAB-C 7 A/H Seismic Battery Bracket Kit E3 CAB-D 7 A/H Seismic Battery Bracket Kit NetSOLONS-INX-7A/H Seismic Battery Bracket Kit NetSOLO-7100-7A/H Seismic Battery Brckt Kit 90519 E3 CAB-C (INX only) 12 A/H Seismic Battery Bracket Kit E3 CAB-D (INX only) 12 A/H Seismic Battery Bracket Kit NetSOLO NS-INX 12 A/H Seismic Battery Bracket Kit 90520 E3 CAB-B 18 A/H Seismic Battery Bracket Kit E3 CAB-C 18 A/H Seismic Battery Bracket Kit E3 CAB-D 18 A/H Seismic Battery Bracket Kit Retrofit Kits For information on the Gamewell and 7200 Retrofit Kits, refer to the following Data Sheets. 9021-60678 Gamewell Retrofit Kits Data Sheet 9021-60733 7200 Retrofit Kits Data Sheet Inner Door Mounting Capacity Part Number Components Cabinet AA E3ID2-A Cabinet AA, Inner Door, 2-slots 1 LCD-E3 Display and 1 ASM-16/ANU-48 E3ID2-TA Assembly, Door, Inner, TEL-E3 E3ID3-A,Cabinet A, Inner Door, 3-slots 1 NGA or ASM-16 2 ASM-16s/ANU-48 Cabinet AA1 E3ID-A1 Cabinet AA1,Inner Door (Includes Box) 1 NGA or ASM-16 Cabinet A2 E3ID-A2 Cabinet A2, Inner Door, (Includes Box) 1 LCD-E3 Cabinet B E3ID2-B Cabinet B, Inner Door, (Includes Box) 1 LCD-E3 Display and one ASM-16/ANU-48 1 NGA and one ASM-16/ANU-48 B-Slim Cabinet 1 LCD-E3 Display & one RPT-E3 or one DACT-E3 1 ILI-MB-E3 or one ILI95-MB-E3 1 PM-9 or one PM-9G Cabinet C E3ID2-C Cabinet C, Inner Door, 2-slots 1 LCD-E3 Display and 5 Any combination of ASM-16/ANU-48, NGA or Microphone Assemblies 1 Telephone Assembly E3ID3-C Cabinet C, Inner Door, 3-slots 7 Any Combination of ASM-16/ANU-48, NGA, or Microphone Assemblies 1 Telephone Assembly Cabinet D E3ID2-D Cabinet D, Inner Door, 2-slots 1 LCD-E3 Display 11 Any Combination of ASM-16/ANU-48, or NGA or Microphone and 1 Telephone Assembly E3ID3-D Cabinet D, Inner Door, 3-slots 13 Any Combination of ASM-16/ANU-48, NGA or Microphone Assemblies 1 Telephone Assembly 1 Loop Interface or ANX or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater Backbox Mounting Capacity E3BB-BAA Enclosure ‘AA’ (LOC) Size Black 1 INI-VG Series Voice Gateway E3BB-BAA1 AA1 Size Box/Door, Black 1 RPT-E3 Network Repeater E3BB-BB B-Size Box/Door, Black 1 PM-9/PM-9G Power Supply 1 ILI-MB-E3/ILI95-MB-E3 and Backbox Mounting Capacity (Continued) Part Number Components E3BB-BB B-Size Box/Door, Black 1 Additional ILI-MB-E3/ILI95-MB-E3 1 Loop Interface or ANX or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater INX CAB-B Mounting Plate 1 PM-9 or PM-9G 1 INI-VGX 4 AM-50 Series amplifiers E3-INCC-C Plate 1 PM-9/PM-9G Power Supply 1 INI-VG Series Voice Gateway 1 ILI-MB-E3/ILI95-MB-E3 Loop Interface and Additional ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater 1 Optional AM-50 or FPT-GATE-3 Extender Plate E3-ILI-C Plate 1 PM-9/PM-9G Power Supply 1 ILI-MB-E3 or ILI95-MB-E3 2 Additional ILI-MB-E3/ILI95-MB-E3 or ILI-S-E3/ILI95-S-E3 or ANX 1 DACT-E3 1 RPT-E3 1 Optional FPT-GATE-3 Extender Plate E3-INX-C Plate 1 PM-9/PM-9G Power Supply with one PM-9/PM-9G Adapter Plate 1 INI-VGX Voice Gateway 1 ILI-MB-E3 Loop Interface and 1 Additional ILI-MB-E3/LI95-MB-E3/ANX 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater 4 AM-50 Series Amplifier 1 Optional FPT-GATE-3 Extender Plate E3-INCC-D Plate 1 PM-9/PM-9G Power Supply 1 ILI-MB-E3 or ILI95-MB-E3 4 Additional ILI-E3 or ILI95-E3 Series or ANX 1 DACT-E3 Digital Communicator 1 RPT-E3 Network Repeater 1 INI-VG Series 1 Optional AM-50 or FPT-GATE-3 Extender Plate E3-INX-D Plate 1 PM-9/PM-9G Power Supply 1 ILI-MB-E3 or ILI95-MB-E3 1 DACT-E3 Digital Communicator 1 RPT-E3 Network Repeater 1 INI-VG Series 4 AM-50 Series Amplifier 1 Optional FPT-GATE-3 Plate E3BB-BD D-size Box/Command Center (Voice), Black 1 PM-9/PM-9G Power Supply 1 INI-VG Series Voice Gateway 4 ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface 1 Additional ILI-MB-E3/ILI95-MB-E3/ ANX Loop Interface or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater 1 Optional FPT-GATE-3 Plate E3BB-BD D-size Box/Command Center, Black 1 PM-9/PM-9G Power Supply 7 ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface & Additional ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface or 1 DACT-E3 Digital Communicator and 1 RPT-E3 Network Repeater Optional Extender Plates AM-50 Extender Plate 1 AM-50-25 or AM-50-70 FPT-GATE-3 Extender Plate 1 FocalPoint® Gateway 1 PNET-1 1 Optional FPT-GATE-3 Extender Plate E3 Series® Cabinets Technical Specifications 9020-0649 | W | 06/18 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, FocalPoint® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. Lexan® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s E3 Series® Cabinets and other products available by visiting www.Gamewell-FCI.com STANDARDS The E3 Series fire alarm control panel cabinets are designed to comply with the following standards: UL Standards: UL 864 9th Edition: Automatic Fire Detector Alarm Manual Fire Alarm Waterflow Alarm Supervisory Releasing Device Service Releasing/Pre-Action Deluge Releasing/Agent Releasing Automatic Smoke Alarm, Non-coded and Master Coded Operation Underwriters Laboratories Standard UL 2572 (Mass Notification Systems). UUKL for Smoke Control UL2572 1st Edition NFPA Standards NFPA 13 - Standard for Installation of Sprinkler Systems NFPA 16 - Standard for Foam-Water Sprinkler and Foam Water Spray Systems NFPA 72 - National Fire Alarm Code: Central Station Fire Alarm Systems Auxiliary Fire Alarm Systems Proprietary Fire Alarm Systems Local Fire Alarm Systems Remote Station Fire Alarm Systems NFPA 13 Sprinkler NFPA 12A Halon 1301 NFPA 15 Water Spray NFPA 16 Foam Water NFPA 750 Water Mist NFPA 2001 Clean Agent NFPA 12 CO2 Carbon Dioxide NFPA 17 Dry Chemical/17A Wet Chemical Seismic Codes International Building Codes: IBC 2013 IBC 2009 IBC 2006 IBC 2003 IBC 2000 (Seismic) California Building Code CBC 2007 (Seismic) STANDARDS The E3 Series Cabinets are designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S1869 MEA Approved: 6177 Fire Dept. of New York: COA# 6077 CSFM: 7165-1703-0125 FM Approved: 3025415 City of Chicago City of Denver VMA Seismic Certified ISO 9001 Certification LCD-SLP STANDBY PRE-ALRM P-RELEASE RELEASE ABORT FIRE ALARM HAZARD SUPERVISORY TROUBLE AC SILENCED MENU DRILL RESET LCD-SLP LCD Touchscreen Annunciator Display Analog and Networking Systems General The Gamewell-FCI, Liquid Crystal Display, Smart Loop Panel (LCD-SLP) is a touchscreen annunciator display used with the S3 Series and E3 Series® Systems. The LCD-SLP provides an easy-to-use, intuitive interface for the operator’s control. The 4.3” (10.92 cm) color touchscreen display shows the following: The following identify the LED Indicators that display on the panel. The five fully-programmable front panel switch/LED combinations provide a direct access to perform the following tasks: The display features the following physical switches. Installation The LCD-SLP panel’s adaptable design allows it to be mounted in a variety of S3 Series, E3® Series or Retrofit cabinet installations. For additional information, refer to the E3 Series Cabinets Data Sheet, P/N:9020-0649. Ordering Information LCD-SLP: LCD Touchscreen display unit E3BB-BA2: Remote enclosure with inner door, black, one LCD slot E3BB-RA2: Remote enclosure with inner door, red, one LCD slot E3BB-FLUSH-LCD: Remote flush mounting enclosure, black, LCD slot FEATURES & BENEFITS • Listed per ANSI/UL® Standard 864 9th Edi- tion • UL Listed and FM approved for Pre- Action/Deluge and Agent Releasing • Provides 4.3” (10.92 cm) color touchscreen dis- play of System Events • Includes five custom function buttons with LEDs for direct access to system controls. • Shows the Hazard LED to indicate gas, carbon monoxide or other toxic gases • Both the E3 Series (ILI- MB-E3/ILI95-MB-E3) and the S3 Series (SLP) support up to 15 LCD- SLP displays via the RS- 485 serial interface • Offers the following installation options: – Locally mounted in the E3 Series and S3 Series panels – Remotely mounted in the E3 Series, A2 cabinet – LCD Flush enclosure • Displays the following six LED indicators: – AC Power – Alarm – Hazard – NAC Silence – Supervisory – Trouble • System Status • Event Details • Service Modes • AC (green) • Fire Alarm (red) • Hazard (blue) • Supervisory (yellow) • Trouble (yellow) • Silenced (yellow) • Device Bypass • Lamp Test • Enable/Disable Groups or Devices • Menu • System Reset • Drift Walk Test • Five Programmable Switches •S3 Series Cabinets – SLP-BB basic system enclosure – S3BB-BB/S3BB-RB system enclosure • E3 Series® Cabinets – AA size cabinet (E3BB-BAA, E3BB-RAA) – A2 size cabinet (E3BB-BA2, E3BB-RA2) – A size flush cabinet (E3BB-FLUSH-LCD) – B-Slim cabinet (E3BB-RBSLIM) – B size cabinet (E3BB-BB, E3BB-RB) – C size cabinet (E3BB-BC/INCC, E3BB-RC/INCC) – D size cabinet (E3BB-BD/INCC, E3BB-RD/INCC) • Retrofit Cabinets – 600-RETROFIT – 7200-B-RETROFIT – 7200-C-RETROFIT LCD-SLP Technical Specifications 9021-60782 | F | 09/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s LCD-SLP and other products available by visiting www.Gamewell-FCI.com SPECIFICATIONS Operating Voltage: 24 VDC FWR Operating Current: 0.030 amp Alarm Current: 0.065 amp Operating Temperature: 32°to120° F (0°to49° C) Relative Humidity: 0 to 93%,non-condensing at 90° F (32° C) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The LCD-SLP is designed to comply with the following standard: UL Standard: UL 864 9th Edition: AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 FM Approved MEA FDNY: COA # 6162 CSFM: 7165-1703:0176 City of Chicago Approved: Class 1 Reference Certificate of Compliance: VMA 45894-02C ISO 9001 Certification SLC-PM (System Sensor) SLC95-PM (Apollo) SLC-PM/SLC95-PM SLC Personality Loop Modules Analog and Networking Systems General The Gamewell-FCI®, S3 Series (Small Addressable Fire Alarm Control Panel) signaling line circuits (SLCs) provide the communication between the S3 Series fire alarm control panel and the SLC devices. Each SLP-E3 (Smart Loop Panel) main board supports either one or two of the following plug-in SLC-Personality Modules. • SLC-PM (Signaling Line Circuit Personality Module) • SLC95-PM (Signaling Line Circuit-95-Personality Module) The SLC-PM/SLC95-PM modules provide one SLC loop in Class B or Class A wiring. The SLC-PM supports the following devices: • Up to 318 System Sensor Velociti® devices. - 159 sensors and 159 modules • Up to 198 System Sensor CLIP devices. - 99 sensors and 99 modules The SLC95-PM supports the following devices: • Up to 126 Apollo XP95 devices. - 126 sensors and modules Installation The SLC-PM/SLC95-PM modules are designed to be plugged into the Smart Loop Panel-Main Board (SLP-E3). This feature allows you to expand the S3 Series (Small Addressable Fire Alarm Control System without the need to remove or replace hardware. Ordering Information SLC-PM: System Sensor, Signaling Line Circuit-Personality Module with up to 318 devices SLC95-PM: Apollo SLC Personality Module with up to 126 devices FEATURES & BENEFITS • Listed per ANSI/UL® Standard 864 9th Edition • SLC-PM supports the System Sensor Velociti protocol using up to 318 devices – Uses up to 159 sensors and 159 modules • SLC95-PM supports the Apollo XP95 protocol using up to 126 devices – Uses up to 126 sensors and modules • Supports Class A or Class B Wiring • Offers a simple, plug-in installation feature SLC-PM/SLC95-PM Technical Specifications 9021-60781 | E | 09/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx Velociti® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s SLC-PM/SLC95-PM and other products available by visiting www.Gamewell-FCI.com SYSTEM TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The SLC-PM/SLC95-PM are designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 FM Approved MEA FDNY: COA # 6162 CSFM: 7165-1703:0176 City of Chicago Approved: Class 1 Reference Certificate of Compliance: VMA 45894-02C ISO 9001 Certification SLC-PM SLC95-PM Operating Current: 0.014 amp 0.016 amp Alarm Current:0.014 amp 0.016 amp Line Impedance:40 Ohms Line Capacitance:0.5 uf max. Operating Voltage:24 VDC FWR Operating Temperature:32° to 120° F (0° to 49° C) Relative Humidity:0 to 93%,non-condensing at 90° F (32° C)