2019.0500.BP0036 DBO-MOORE-CALCS (1)James W. Ashley -Cole, P.E. CONSULTING ENGINEER CALCULATION SUBMITTAL For Moore Residence Canopy Addition 9975 Charles St. SE Yelm WA Prepared for: Steven Moore 9975 Charles St. SE Project No. 2019.121 Extent of Analysis: The structural details, general notes, and sealed engineering calculations included with this submittal have been prepared exclusively for the project referenced above. The scope of this submittal has been limited to an engineering analysis and design of the primary components of the canopy structure in accordance with the 2015 International Building Code. • All fl ashings, coatings, membranes and sealants are by the contractor. Design Criteria: Roof: 25 PSF Wind: 85 MPH, Exposure B, I = 1.0 Seismic: Sds (Seismic Design Category D) = 0.8334, R = 6.5,1= 1.0 525 Columbia Street NW, Suite 201 Olympia WA 98501 t. 360.709.0807 f. 360.786.8474 STRUCTURAL NOTES These structural notes apply to all structural components of the primary structural systems. Any discrepancies found among the drawings, these notes and the site conditions shall be reported to the Engineer of Record, who shall correct such discrepancy in writing. Any work done by the Contractor after discovery of such discrepancy, but prior to correction of such discrepancy, shall be done at the Contractor's risk. • The Contractor shall field locate and identify all site utilities prior to performing any site excavation or demolition. The Contractor shall be responsible for all safety precautions and methods, techniques, sequences or procedures required to perform the Contractor's work. The Consulting Engineer has no overall supervisory authority or actual and/or direct responsibility for the specific working conditions at the site and/or for any hazards resulting from the actions of any trade contractor. The Consulting Engineer has no duty to inspect, supervise, note, correct, or report any health or safety deficiencies to the Owner, Contractor, or other entities or persons at the project site. • It is the Contractor's responsibility to verify all field measurements and site conditions prior to fabrication of any structural elements. No allowance will be made for any items incorrectly fabricated or installed due to failure to perform such verification prior to commencing work. Contractor initiated changes shall be submitted to the Consulting Engineer in writing for approval prior to fabrication, construction or field modification. Changes shown on shop drawings only will not satisfy this requirement. Non-structural building systems, including: flashings, membranes, coatings, sealants or ventilation are not the responsibility of the Consulting Engineer, CONSTRUCTION STABILITY The design, adequacy and safety of erection bracing, shoring and all temporary supports is the sole responsibility of the Contractor, and has not been considered by the Consulting Engineer. The Contractor shall provide the bracing necessary to provide stability to the structure prior to the completed application of the lateral system. During construction the Contractor shall lceep loads within the design roof and floor loads limits shown on the drawings. CODES AND DESIGN All methods, materials and workmanship shall conform to the 2015 edition of the International Building Code (IBC) as amended and adopted by the local Building Department. All reference to other codes and standards, such as ACI, ASTM, AISC, etc. shall be for the latest or most current edition available. DESIGN LIVE LOADS Roof: 25 PSF Wind: 85 MPH (Allowable Stress Design), Exposure B. Seismic: Sds (Seismic Design Category D) = 0.8334, R = 6.5, I = 1.0 SOIL BEARING The foundation has been designed for 1500 PSF bearing. GENERAL FRAMING NOTES • Nails: Nails designated for roof and floor diaphragms, and in the shear all schedule, shall have the following minimum diameters; 16d common nail : Shank diameter = 0.162 inches minimum, Length = 3.5 inches. 16d galvanized box nail : Shank diameter = 0.135 inches minimum, Length = 3.5 inches. I Od common nail : Shank diameter = 0.148 inches minimum, Length = 3.0 inches. IOd galvanized box nail : Shank diameter = 0.128 inches minimum, Length = 3.0 inches. 8d common nail: Shank diameter = 0.131 inches minimum, Length = 2.5 inches. 8d _galvanized box nail : Shank diameter = 0.113 inches minimum, Length = 2.5 inches. • All fasteners in preservative treated material shall be either hot dipped galvanized, tumbled or stainless steel of American or Canadian manufactured only. • Minimum nail penetration in backing framing = 1 1/2 inches. • Sheathing Notes: Place sheathing with the long dimension perpendicular to the supports and with a staggered layout. All sheathing panels shall be 4 ft x 8 ft minimum. At edges of roof diaphragms where sheets may be smaller than 24 inches, unsupported sheathing edges shall be fully blocked and nailed per the shear wall schedule, or 6 inches o/c minimum. All call outs for nails in these notes and details correspond to COMMON type nails. • Dimensions; Contractor shall field verify and coordinate all dimensions shown with the existing conditions prior to fabrication of any structural components. STRUCTURAL CONCRETE Special Inspection not Required GENERAL All concrete shall meet the requirements of ACI -301, "Specifications For Structural Concrete For Buildings." Proportioning of ingredients for each concrete mix shall be by Method 2 or the alternate procedure given in ACI -301, Chapter Seven. Place concrete per ACI -304 and conform to ACI -306R for cold weather placement and ACI -305R for hot weather placement. All concrete thicker or deeper than 4 inches shall be vibrated during placement. Use internal mechanical vibrators. Do not over -vibrate. Inserts, bolts, boxes, pipes, conduits, and other accessories shall be securely installed and inspected prior to placing concrete. Remove water, debris, wood, and loose concrete from space where concrete is to be placed. Protect all concrete from premature drying, excessive hot or cold temperature. Curing should start immediately after the concrete has been finished and be continued for at least seven (7) days. PROPERTIES Footings, foundation walls and slab -on -grade: • f c 3000 PSI minimum at 28 days, 5 '/2 sack minimum mix Slump: 5 inches maximum 4 inches maximum at interior slab -on -grade water / cement: 0.45 maximum by weight air entrainment : 5% +/- 1% 3% +/- 1% at interior slab -on -grade 3/4 inch maximum size aggregate Cement: ASTM C150, normal — Type I or I-II Coarse and fine aggregate: ASTM C33 Water shall be clean and not detrimental to concrete. ADMIXTI]RES Water reducing admixture: ASTM C494, Type A. Admixtures shall be used in exact accordance with manufacturer's instructions. Air entrainment: ASTM C260 and ASTM C494, except those containing chlorides may not be used. No other admixture permitted unless approved by the Consulting Engineer. Do not use calcium chloride or related materials. PLACEMENT A. General: Comply with requirements of ACI 304 and as follows: 1. Schedule continuous placement and consolidation to prevent formation of cold joints. 2. Deposit concrete as close as possible to its final location, to avoid segregation. 3. Thoroughly consolidate without displacing reinforcing using internal vibrators. 4. Strike off and level concrete slab surfaces, using bull floats before bleed water can collect on surface. Do not work concrete further until finishing operations are commenced. REINFORCING STEEL Reinforcing steel shall conform to ASTM A615 Grade 60 new billet stock, deformed steel free of rust, scale or other bond -reducing coatings. Tie bars securely with #16 double annealed wire. Fabricate in accordance with ACI 315. Provide support as indicated or recommended by ACI STD 315. Reinforcing shall be placed in accordance with " CRSI Recommended Practice For Placing Reinforcing Bars." CONCRETE COVER The following concrete cover shall be provided for reinforcement: • Concrete cast against and permanently exposed to earth: 3 inches for footings 2 inches for interior slab -on -grade • Concrete exposed to earth or weather: 1'/2 inches for #5 bars and smaller and WWF CONCRETE DOWELING ADHESIVE (CDA) INTO CONCRETE AND SOLID MASONRY Adhesive anchors shall consist of a threaded anchor rod, nut, and washer and an injectable adhesive material. Manufacturer's instructions shall be followed for all installation steps including: material handling and storing, substrate drilling and cleaning, and adhesive installation. The injectable adhesive material shall be HIT HY 200 (A or R), as manufactured by Hilti, Inc or SET -PACK EZ, as manufactured by Simpson. 1. Only injection tools and static mixing nozzles recommended by the manufacturer shall be used. 2. Anchor rods shall be ASTM A36 furnished with two chamfered end so that either end will accept a nut and washer. C�.ZiZi77 ill\U 1 ► !!:\►1711i1►I - : _ 1 ► , Allowable stress required shall be in accordance with standard grading rules of West Coast Lumber No. 16. Moisture content shall be maximum 19%. All studs, plates and blocking at shear walls, load bearing and exterior studs and plates shall be of grade Douglas -fir #2 or better, unless noted otherwise. Wood framing details, not shown otherwise, shall be constructed to the minimum standards of the 2015 IBC and shall conform to the Fastening Schedule 2304.9.1. Unless noted otherwise, all nailing callouts refer to common type nails. Notations on drawings relating to framing clips, joist hangers and other connectors refer to catalog numbers manufactured by the Simpson Strong Tie Company, San Leandro, CA, Catalog C-2019. All hangers in contact with preservative treated lumber shall be "Z -MAX" galvanized with approved fasteners as noted. 1�7 Di.� i��iL•11 M �iLi�L11�11 Y Dl_I � � � 1 Preservative treatment: All lumber required to be preservative treated shall conform to the requirements of the applicable AWPA Standards, per the 2015 IBC Section 2302.1.8. Preservatives shall conform to AWPA P1/P13, P2, P5, P8, and P9. Preservative -treated wood shall bear the quality marls of an inspection agency per the 2015 IBC Section 2302.1.8.1. Each piece of treated lumber shall bear an approved quality mark or that of an approved inspection agency which maintains continuing supervision, testing and inspection over the quality of the product, as described in the IBC standards, and shall be identified as required by these standards. Where FDN lumber is cut or drilled after treatment, the cut surface shall be field treated with approved preservatives by repeated brushing, dipping or soaking until the wood absorbs no more preservative. Fasteners: Fasteners for preservative -treated wood shall be of hot -dipped zinc -coated galvanized steel, stainless steel, silicone bronze or copper. Fastenings for wood foundations shall be as required in AF & PA Technical Report No. 7. SECTIONS AND DETAILS Sections and details showing reinforcing, bolts, framing members, and connections are intended to illustrate specific detail. No attempt has been made to show all elements passing through a specific section or detail. Exposed bolted beam connections may have to be furred by the Contractor to conceal connector. Construction details not specifically shown on the drawings shall follow similar details or sections of this project as approved by the Consulting Engineer. James W. Ashley -Cole, P.E. rl�ZJ CONSULTING ENGINEER �CICYL/G «� • ?/V PROJECT DATE: /G/ SHEET C 4A /iC< f I <tl )4�3;2 I CONSULTING ENGINEER v '6507 �> so Of 3 PROJECT NUMBER:�� /Z 1 DATE: �z�� I SHEET , OF J�o fz:�2D.8 /rtr/ _ t1?ar_ Z wro . - f S i rem d to ill!oo 5 s /4 - g l James W. Ashley -Cole, P.E. CONSULTING ENGINEER PROJECT NUMBER:/ DATE:— SHEET 2 OF of F ''t �,UtL✓� GLI, _ P cS LVA _ �- �fw4c 4 (P ua°L r' _ ir3:: l 04000 > 7vz �o n i r TL - z /� mw Wpz� t�:3 P3 I`��� =w �) �� t