Loading...
2020.0024.BP0002 200128_FtStevensES_PermitFLOOR FINISH TRANSITION SHEET NOTE REVISION EXTERIOR ELEVATION DETAIL CALLOUT - SECTION CUT LINE DOOR NUMBER CALLOUT WALL TYPE CALLOUT WINDOW TYPE CALLOUT LOUVER TYPE CALLOUT CENTER LINE DETAIL CALLOUT - PLAN RELITE TYPE CALLOUT STOREFRONT TYPE CALLOUT INTERIOR ELEVATION 1 A-201 1 A-591 SIM 1 A-591 SIM ELEVATION MARKER DATUM POINT NAME ELEVATION 1 BREAK LINE, ROUND VCTCPTA-211 2 3 4 1 101L1 ROOF TYPE CALLOUT ROOM NAME/NUMBER CEILING HEIGHT SLOPE INDICATOR GRAPHIC SCALE SLOPE 6:12 12 6 SCALE: 0 4 8 16 1/8" = 1'-0" 11'-0" ROOM NAME 101 FLOOR/CEILING TYPE CALLOUT WALL SECTION BUILDING SECTION 1 A-311 A A-301 A A-301 6W1 R1 FC1 CLCL PLAN NORTH NORTH ARROW TRUE NORTH R1 SF1 1 SHEET NOTE - DEMOLITION1 W1 TRUE NORTH SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:13:41 PMG-101F 1.23.2020 19024.04 INDEX SHEET, PROJECT INFORMATION, PROJECT TEAM PERMITFORT STEVENS ELEMENTARY SCHOOL16525 100TH WAY SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 2GENERAL G-101F INDEX SHEET, PROJECT INFORMATION, PROJECT TEAM G-201F CODE INFORMATION A-111F SITE PLAN A-121F FIRST FLOOR PLAN - OVERALL A-401F ENLARGED PLANS A-501F DETAILS A-611F DOOR SCHEDULE AND TYPES, WALL AND ROOF ASSEMBLIES NUMBER SHEET DRAWING DESCRIPTION ARCHITECTURAL VICINITY MAP SHEET INDEX PROJECT TEAM ABBREVIATIONS ARCHITECTURAL SYMBOLS PROJECT INFORMATION AFF ABOVE FINISHED FLOOR CG CORNER GUARD DS DOWNSPOUT EQ EQUAL FV FIELD VERIFY GA GAUGE GWB GYPSUM BOARD MAX MAXIMUM MDF MEDIUM DENSITY FIBERBOARD MIN MINIMUM NIC NOT IN CONTRACT OC ON CENTER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OPP OPPOSITE PPT PRESSURE PRESERVATIVE TREATED SIM SIMILAR TB TACKBOARD TYP TYPICAL UNO UNLESS NOTED OTHERWISE WB WHITEBOARD SITE ADDRESS 16525 100TH WAY SE, YELM, WA 98597 PARCEL NO. 64303600300 JURISDICTION CITY OF YELM SCOPE OF WORK SAFETY AND SECURITY UPGRADES TO THE EXISTING SCHOOL, INCLUDING: NEW SECURITY VESTIBULE, NEW INTERIOR CORRIDOR AND CLASSROOM DOORS, ACCESS CONTROL SYSTEM ON DOORS, CCTV SYSTEM, MODIFICATIONS TO EXISTING LIGHTING AND FIRE SPRINKLER AS REQUIRED TO ACCOMMODATE NEW VESTIBULE. FORT STEVENS ELEMENTARY SCHOOL 16525 100TH WAY SE YELM, WA 98597 YELM COMMUNITY SCHOOLS OWNER 107 1ST STREET N YELM, WA 98597 BCRA, INC ARCHITECT 2106 PACIFIC AVENUE, SUITE 300 TACOMA, WA 98402 CONTACT: HEATHER HOCKLANDER PHONE: 253.627.4367 PCS STRUCTURAL SOLUTIONS STRUCTURAL 1250 PACIFIC AVENUE, SUITE 701 TACOMA, WA 98402 CONTACT: WES NEELEY PHONE: 253.383.2797 YELM COMMUNITY SCHOOLS OWNERS REP PO BOX 476 YELM, WA 98597 CONTACT: KASEY WYATT PHONE: 360.458.1900 BCE ENGINEERS ELECTRICAL 6021 12th ST. EAST, SUITE 200 FIFE, WA 98424 CONTACT: CARRIE TAYLOR PHONE: 253.922.0446 ADAMS CONSULTING DOOR HARDWARE 2337 N 57TH ST SEATTLE, WA 98103 CONTACT: GORDON ADAMS PHONE: 206.528.0244 T-001F SECURITY LEGEND LIGHTING FIXTURE SCHEDULE T-101F SITE PLAN - SECURITY T-111F FIRST FLOOR PLAN - AREA 1 - SECURITY T-112F FIRST FLOOR PLAN - AREA 2 - SECURITY T-113F FIRST FLOOR PLAN - AREA 3 - SECURITY TELECOM PERMIT - 1.23.2020 SAFETY & SECURITY IMPROVEMENTS 2 M-001 FIRST FLOOR MECHANICAL PLAN MECHANICAL 880 SF 45 OCC CLASSROOM 880 SF 44 OCC CLASSROOM 869 SF 44 OCC CLASSROOM 868 SF 44 OCC CLASSROOM 863 SF 44 OCC CLASSROOM 919 SF 46 OCC CLASSROOM 840 SF 43 OCC CLASSROOM 884 SF 45 OCC CLASSROOM 807 SF 41 OCC CLASSROOM 1055 SF CLASSROOM HALLWAYEXIT EXITTWO EXITS LEADING TO PUBLIC WAY PROVIDED FROM HALLWAY NEW DOOR NEW DOORS AND VESTIBULE. NO CHANGES TO EXISTING EXIT CAPACITY MAX OCC SIGNAGE PROVIDED: "MAXIMUM OCCUPANCY 49" 962 SF 49 OCC CLASSROOM860 SF 43 OCC CLASSROOM 900 SF 46 OCC CLASSROOM 887 SF 45 OCC CLASSROOM 898 SF 45 OCC CLASSROOM 868 SF 44 OCC CLASSROOM 49 OCC 2-HR RATED WALL, REFER TO DETAIL 3/A-501F 2-HR RATED WALL NEW KNOX BOX SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:32:29 PMG-201F 1.23.2020 19024.04 CODE INFORMATION PERMITFORT STEVENS ELEMENTARY SCHOOL16525 100TH WAY SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 2Author 1/16" = 1'-0"1 CODE PLAN OCCUPANCY GROUPS: PRIMARY: EDUCATIONAL (E) CONSTRUCTION TYPE: WOOD FRAMING, FULLY SPRINKLERED EGRESS: NO CHANGES TO EXISTING EXITING ROUTES. REFER TO PLAN FOR NEW DOORS BUILDING ROOFS: INSULATION ENTIRELY ABOVE DECK: R-VALUE: R-30ci *VESTIBULE IS AN UNCONDITIONED SPACE WALLS: ABOVE GRADE, WOOD FRAMED: R-VALUE: R-21 VERTICAL FENESTRATION: METAL FRAMING, FIXED: U-FACTOR: 0.38 METAL FRAMING, ENTRACE DOORS: U-FACTOR: 0.60 LIGHTING: NO MORE THAN 50 PERCENT OF THE LUMINAIRES ARE BEING REPLACED. NEW LUMINAIRES ARE REDUCED WATTAGE LED TYPE IN ACCORDANCE WITH C503.6. ENERGY CODE INFORMATION FIRE SPRINKLER, FIRESTOPPING DEFERRED SUBMITTALS SEPTIC DRAINFIELD SEPTIC DRAINFIELD SEPTIC RESERVE SEPTIC RESERVE 8" WATERMAIN 8" WATERMAIN F.H. F.H.10" WATERMAIN BY OTHERSF.H. 8" WATERMAIN 8 " W A T E R M A I N F.H. PROPOSED CONNECTION SANITARY SEWER PROPOSED CONNECTIONS STORM SYSTEMSSSSSSSSSTSTSTST S T ST STS T STSTSTSTS T 190 LF 12" PER F PIP E350'BASEBALL FIELD SOFTBALL FIELD PEA GRAVEL PIT PLAY AREA 350' CONVERTED PLAYSHED EXISTING ELEMENTARY SCHOOL FF=341.0PLANTER AREABUS PARKING ASPHALT PAVING PARKING MAZE GATE 50' EASEMENT FOR ELEC TRANS LINE PLANTER AREA ASPHALT PLAY AREA SERVICE (E) PLANTER AREA EXISTING PORTABLES FH FH FH PLANTER AREA NEW PLAYSHED NEW DOUBLE PORTABLES (E) PLANTER AREAS (E) PLANTER AREA (E) BRICK PAVED AREA MIDDLE ROAD SE LAWN LAWN LAWN P.P. P.P. P.P. OVERHEAD POWER LINE GUY WIRE D ISTRIC TSTO RA G EBUILD IN G 9000 S.F.FRONT YARD SET BACK 15'-0" TYPICAL NEW TYPE I LANDSCAPING CONCRETE WALKS GRAVEL ACCESS ROAD HOP A-401F 4 A-401F5 SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:13:37 PMA-111F 1.23.2020 19024.04 SITE PLAN PERMITFORT STEVENS ELEMENTARY SCHOOL16525 100TH WAY SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 2TRUE NORTH 1" = 50'-0"1 SITE PLAN 0 25 50 100 1" = 50'-0" SCALE: 118.2115 111 103.2102.2153.2158154.2154.1153.1 155.1 156.1 155.2 156.2 157.2 148.2 149.2 162168 167.1169.1307.1 301.1 306.1302.1167.2304.1169.2175.2 176.2 176.1 184.1 185.1 175.1187185.2 184.2 142.2182.1183.2 182.2181127.3 200.1 127.2 127.1 136202.2307.2306.2305.2301.2302.2303 304.2 305.1183.1101.2157.1 143 A-401F 1 147 100.1102.1 A-611F 1 TYP OF 5, THIS POD A-611F 1 TYP OF 4, THIS POD A-611F 1 TYP OF 6, THIS POD A-611F 1 SIM A-611F 1 SIM A-611F 1 A-611F 1 SIM SIM 2-HR RATED WALL 2-HR RATED WALL 1. ALL DOORS ARE EXISTING TO REMAIN U.N.O. PROTECT FROM DAMAGE DURING SCOPE OF WORK. NEW DOOR NOTE:NOT ALL LEGEND ITEMS MAY BE PRESENT ON THIS SHEET NEW RELITE / WINDOW NEW WALL NEW WALL EXISTING RELITE / WINDOW EXISTING DOOR EXISTING WALL EXISTING WALL 000.0 000.0 EXISTING DOOR RECIEVING UPDATES EXISTING WALL 2-HR RATED WALL, REFER TO DETAIL 3/A-501F SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:13:38 PMA-121F 1.23.2020 19024.04 FIRST FLOOR PLAN - OVERALL PERMITFORT STEVENS ELEMENTARY SCHOOL16525 100TH WAY SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 21/16" = 1'-0"1 FIRST FLOOR PLAN - OVERALL FLOOR PLAN GENERAL NOTES FLOOR PLAN LEGEND 0 8 16 32 1/16" = 1'-0" SCALE: PLAN NORTH T R U E N O R T H 101.2102.2 A-401F 4 RELOCATED DOWNSPOUT EXISTING ROOF ABOVEABOVENEW ROOFA-401F5 6 A-401F 6W1 NEW DOWNSPOUT. SAWCUT, PATCH, AND REPAIR AT BASEALIGN100.1102.1 ALIGN NEW WALK-OFF MAT EXISTING PAVING 1. ALL DOORS ARE EXISTING TO REMAIN U.N.O. PROTECT FROM DAMAGE DURING SCOPE OF WORK. NEW DOOR NOTE:NOT ALL LEGEND ITEMS MAY BE PRESENT ON THIS SHEET NEW RELITE / WINDOW NEW WALL NEW WALL EXISTING RELITE / WINDOW EXISTING DOOR EXISTING WALL EXISTING WALL EXISTING DOOR RECIEVING UPDATES EXISTING WALL 000.0000.0BRICK COURSINGMATCH EXISTINGSHEET METAL FLASHING AT TOP OF BRICK 6W1 6W1 SIM SF-1 NEW KNOX BOX EXISTING BRICK WALLS TO REMAIN EXISTING ROOF NEW ROOF TO MATCH SLOPE OF EXISTING ROOF SHEET METAL GUTTER EXISTING GLB NEW GWB CEILING 5-1/8"x12" GL 2x6 AT 24" O.C.10'-9"R1 A-501F 1 BEVELED PLATE OVER DOUBLE TOP PLATE BEYOND 6 A-401F EXISTING ROOF ABOVE NEW ROOF STRUCTURE REMOVE EXISTING PLYWOOD SOFFIT, INSTALL R-30 BATT INSULATION, MAINTAIN AIR SPACE NEW GWB LID NEW DOOR AND FRAME PER PLAN, CENTER IN EXISTING OPENING EXISTING WOOD TRIM, MAINTAIN NEW WALL, 6W2 EQ EQ CL 7 A-401P AT 'SIM': EXTEND NEW WALL TO ADJACENT GWB WALLS NEW DOOR AND FRAME PER PLAN, CENTER IN EXISTING OPENING EXISTING WOOD TRIM, MAINTAIN NEW WALL, 6W2 EQ EQ CL AT 'SIM': EXTEND NEW WALL VERTICALLY TO CEILING HEIGHT NOTE:NOT ALL LEGEND ITEMS MAY BE PRESENT ON THIS SHEET NEW RELITE / WINDOW NEW WALL EXISTING RELITE / WINDOW EXISTING WALL NEW 5/8" GWB LID A-401F 4 6 A-401F R1 EXISTING ROOF NEW ROOF SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:13:39 PMA-401F 1.23.2020 19024.04 ENLARGED PLANS PERMITFORT STEVENS ELEMENTARY SCHOOL16525 100TH WAY SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 2Author 1/4" = 1'-0"1 VESTIBULE FLOOR PLAN FLOOR PLAN GENERAL NOTES FLOOR PLAN LEGEND 0 2 4 8 1/4" = 1'-0" SCALE: PLAN NORTH REFLECTED CEILING PLAN LEGEND 1/4" = 1'-0"4 EXTERIOR ELEVATION 1/4" = 1'-0"5 INTERIOR ELEVATION 1/4" = 1'-0"6 VESTIBULE WALL SECTION 1/4" = 1'-0"2 VESTIBULE REFLECTED CEILING PLAN 1/4" = 1'-0"7 INFILL DOOR PLAN 1/4" = 1'-0"8 INFILL DOOR ELEVATION 1/4" = 1'-0"3 ROOF PLAN CONTINUOUS SILL GASKET SAWCUT AND REMOVE EXISTING CONCRETE SLAB ON GRADE AS REQUIRED FOR NEW FOOTING PPT 2x SILL PLATE WITH 5/8" AB AT 32" O.C. BACKER ROD AND SEALANT SEAL AIR/WATER BARRIER TO CONCRETE AND SILL PLATE WATERTIGHT (AIR BARRIER) (2) #5 REBAR LONGITUDINAL 6" WIDE STEM WALL WITH #4 AT 18" O.C. DOWELS AND (2) #5 REBAR AT TOP 6"12" MIN11"18"4"4" S.O.G WITH #4 AT 18" O.C. EACH WAY WALL NEW CONDUIT UL APPROVED AND TESTED SEALANT TO COMPLETELY FILL ANNULAR SPACE, PAINT TO MATCH ADJACENT AT EXPOSED TO VIEW CONDITIONS INTERIOR CONDITIONS: SEAL ANY PENETRATIONS THROUGH WALLS WITH FIRESTOPPING TO MAINTAIN EXISTING FIRE AND ACOUSTIC RATING OF WALL EXTERIOR CONDITIONS: SEALANT AS SPECIFIED IN SECTION 07 9000 SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:13:40 PMA-501F 1.23.2020 19024.04 DETAILS PERMITFORT STEVENS ELEMENTARY SCHOOL16525 100TH WAY SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 21 1/2" = 1'-0"1 FOOTING 3" = 1'-0"3 TYPICAL CONDUIT PENETRATION GL-1 1" INSULATED TEMPERED GLASS GL-2 1/4" TEMPERED GLASS 1. FIELD VERIFY ALL DOOR/FRAME OPENING SIZES. FINISH FLOOR 6"6"36"6"PER SCH PER SCH PER SCHPER SCH6"6"36"6"24"PER SCH C PER SCHBA ASSEMBLY TYPE AND DESCRIPTION ASSEMBLY COMPONENTS - PLAN VIEW INTERIOR 2X6 WOOD STUD WALL ASSEMBLY 6W2 SCALE: 1 1/2" = 1'-0" 5/8" TYPE 'X' GYPSUM BOARD 2X6 WOOD FRAMING @ 16" OC 5/8" TYPE 'X' GYPSUM BOARD ASSEMBLY TYPE AND DESCRIPTION ASSEMBLY COMPONENTS - PLAN VIEW EXTERIOR 2X6 WOOD STUD WALL ASSEMBLY 6W1 SCALE: 1 1/2" = 1'-0" BRICK CLADDING WITH 1" AIR GAP (FIBER CEMENT PANEL ON BATTENS AT 'SIM') AIR/WATER BARRIER (AIR BARRIER) 1/2" PLYWOOD SHEATHING WITH #8 AT 6" O.C. AT PANEL EDGE AND #8 AT 12" O.C. AT INTERMEDIATE FRAMING 2X6 WOOD FRAMING @ 16" OC, WITH R-21 BATT INSULATION 5/8" TYPE 'X' GYPSUM BOARD, WITH CLASS III VAPOR RETARDER PAINT INTERIOR EXTERIOR FINISH FLOOR FRAME: ALUMINUM FINISH: - GLAZING: GL-1 MATCH EXISTING 16'-4" ± 6'-0"PER SCHEDULEMATCH EXISTING8'-2" ±SF-1 1 FINISH FLOOR 2 SCHED. PER PER SCHED.SCHED. PER PER SCHED.4"EXISTING MATCH ASSEMBLY TYPE AND DESCRIPTION ASSEMBLY COMPONENTS - SECTION VIEW ASPHALT SHINGLES OVER WOOD STRUCTURE R1 SCALE: 1 1/2" = 1'-0" ASPHALT SHINGLE WITH UNDERLAYMENT RIGID FOAM INSULATION, WITH PLYWOOD NAILER TO MATCH EXISTING R-30 INSULATION/NAILER, MATCH EXISTING ROOF DEPTH 3/4" T&G SHEATHING WITH #10 AT 6" O.C. AT PANEL EDGE AND #10 AT 12" O.C. AT INTERMEDIATE FRAMING 2X6 AT 24" O.C. GWB SOFFIT ROOFING NAILER SCREWS AT 12" O.C. EMBED 1" MIN INTO ROOF FRAMING SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:13:41 PMA-611F 1.23.2020 19024.04 DOOR SCHEDULE AND TYPES, WALL AND ROOF ASSEMBLIES PERMITFORT STEVENS ELEMENTARY SCHOOL16525 100TH WAY SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 2DOOR SCHEDULE - FT STEVENS DOOR NUMBER DOOR FRAME DETAIL CALLOUT FIRE RATING LABEL HARDWARE GROUP REMARKS DOOR NUMBER WIDTH HEIGHT DEPTH TYPE MAT'L FINISH GLAZING TYPE MAT'L FINISH HEAD JAMB SILL100.1 6' - 0" 7' - 0" 1 3/4" C AL FF GL-1 SF-1 AL FF 1 B 100.1 101.2 6' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 2 B 101.2 102.1 3' - 0" 7' - 0" 1 3/4" A HM PT GL-2 2 HM PT 3 102.1 102.2 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 4 102.2 103.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 103.2 111 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 111 115 6' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT B 115 118.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 118.2 127.1 6' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT B 127.1 127.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 127.2 127.3 6' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT B 127.3 136 6' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 9 B 136 142.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT B 142.2 143 6' - 0" 7' - 0" 1 3/4" A WD ST -- EX HM PT A,B 143 147 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 147 148.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 148.2 149.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 149.2 153.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 5 153.1 153.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 153.2 154.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 6 154.1 154.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 154.2 155.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 6 155.1 155.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 155.2 156.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 6 156.1 156.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 156.2 157.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 6 157.1 157.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 157.2 158 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 158 162 6' - 0" 7' - 0" 1 3/4" A WD ST -- 1 HM PT 7 A,B 162 167.1 3' - 0" 7' - 0" 1 3/4" EX WD ST EX HM PT 5 167.1 167.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 167.2 168 6' - 0" 7' - 0" 1 3/4" A WD ST -- 1 HM PT 7 A,B 168 169.1 3' - 0" 7' - 0" 1 3/4" EX WD ST EX HM PT 5 169.1 169.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 169.2 175.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 5 175.1 175.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 175.2 176.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 5 176.1 176.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 176.2 181 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 181 182.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 6 182.1 182.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 182.2 183.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 5 183.1 183.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 183.2 184.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 5 184.1 184.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 184.2 185.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 5 185.1 185.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 185.2 187 6' - 0" 7' - 0" 1 3/4" A WD ST -- 1 HM PT 7 A,B 187 200.1 6' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT B 200.1 202.2 6' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 8 B 202.2 301.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 6 301.1 301.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 301.2 302.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 6 302.1 302.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 302.2 303 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 303 304.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 6 304.1 304.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 304.2 305.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 5 305.1 305.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 305.2 306.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 5 306.1 306.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 306.2 307.1 3' - 0" 7' - 0" 1 3/4" B WD ST GL-2 1 HM PT 5 307.1 307.2 3' - 0" 7' - 0" 1 3/4" EX HM PT EX HM PT 307.2 DOOR SCHEDULE GENERAL NOTES DOOR SCHEDULE REMARKS DOOR SCHEDULE ABBREVIATIONS AL ALUMINUM EX EXISTING FF FACTORY FINISH GL-# GLAZING TYPE HM HOLLOW METAL PT PAINT ST STAIN WD WOOD A. PROVIDE MAGNETIC HOLD OPEN B. PAIR OF DOORS GLAZING TYPES 1/4" = 1'-0"1 DOOR TYPES 1/4" = 1'-0"3 STOREFRONT TYPES 1/4" = 1'-0"2 DOOR FRAME TYPES 0 1 - 2 3 - 2 02 0 SYMBOLDESCRIPTIONSECURITY LEGENDCINTERIOR CCTV CAMERA - 'W' INDICATES WALL MOUNT, 'C' INDICATES CEILING MOUNT, 'CN' INDICATES CORNER MOUNT. SEETHE CCTV RISER DIAGRAM AND MOUNTING DETAILS FOR ADDITIONAL REQUIREMENTS. MAINTAIN THETELECOMMUNICATIONS OUTLET REQUIREMENTS. PROVIDE (1) DATA PORT AND (1) CAT6 CABLE WITH A 10-FOOT SERVICELOOP FOR EACH CAMERA SHOWN ON THE DRAWINGS. MAINTAIN THE TELECOMMUNICATIONS OUTLET REQUIREMENTS.PROXIMITY CARD READER - WALL MOUNT. (M INDICATES MULLION MOUNT). SEE ACCESS CONTROL RISER DIAGRAM AND RELATED DETAILS FOR MOREINFORMATION. MOUNT AT +48" UNLESS NOTED OTHERWISE.DOOR POSITION SWITCH (A DPDT SHALL BE PROVIDED AT EACH LOCATION SHOWN). CONNECT EXISTING INTRUSION CABLINGTO THE NEW DPDT SWITCH. PROVIDE NEW CABLING FOR ACCESS CONTROL MONITORING.ACCESS CONTROL READER I/O INTERFACE - WALL MOUNT ABOVE ACCESSIBLE CEILING SPACE - PROVIDE CABLING TO THENEAREST ACCESS CONTROL PANEL. SEE ACCESS CONTROL RISER DIAGRAM AND RELATED DETAILS FOR MOREINFORMATION.REQUEST TO EXIT - REX SHALL BE INTEGRAL TO THE DOOR HARDWARE AND PROVIDED BY DIVISION 8. PROVIDE NECESSARYCABLING FROM ACP/ ACRI AT EACH LOCATION.ACCESS CONTROL SYSTEM POWER SUPPLYELECTRIFIED EXIT DEVICE - SHOWN FOR REFERENCE ONLY. COORDINATE WITH DOOR HARDWARE FOR EXACT DEVICE AT EACHLOCATION.CACCESS CONTROL PANEL - MOUNTED ABOVE ACCESSIBLE CEILING SPACE. PROVIDE (1) DATA PORT AND (1) CAT6 CABLEWITH A 10-FOOT SERVICE LOOP AT EACH LOCATION. SEE ACCESS CONTROL RISER DIAGRAM AND RELATED DETAILS FORMORE INFORMATION.1.EXISTING ANALOG CCTV SYSTEM IN BUILDING 1 IS TO REMAIN FULLY OPERATIONAL UNTIL NEW IPCCTV SYSTEM IN BUILDING 1 IS FULLY OPERATIONAL. EXISTING ANALOG CCTV SYSTEM TOINCLUDE OLD CCTV CABLING SHALL BE DEMOLISHED AFTER THE VA HAS APPROVED THE NEW IPCCTV SYSTEM. TURN OVER ALL OLD CCTV DEVICES TO THE OWNER. PROVIDE NEW CEILING TILESAS REQUIRED. PATCH ANY WALL AND CEILING SURFACES IN HARD LID AREAS WHERE ANY OLDCAMERAS WHERE INSTALLED. PAINT TO MATCH ADJACENT SURFACE.2.SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR SHEET.3.REVIEW PLANS FOR LOCATIONS OF AREAS WITH ACCESSIBLE CEILING TILES, GWB, AND OPENCEILINGS. PROVIDE MANUFACTURER APPROVED BACK BOXES IN AREAS WITH CEILINGS THAT AREOPEN TO STRUCTURE. ALL CABLE/CONDUIT ROUTING SHALL USE THE EXISTING CORRIDORS ASTHE MAIN ROUTING PATH AS MUCH AS POSSIBLE BEFORE CROSSING INTO OTHER AREAS TO GETTO DEVICE/IDF LOCATIONS. LINE OF SIGHT ROUTING OF THE CABLE/CONDUITS WILL NOT BEACCEPTABLE.4.UTILIZE EXISTING CABLING TRAY WHEN EVER POSSIBLE IN BUILDINGS WITH CABLE TRAY. OPENCABLING IS ACCEPTABLE IN ACCESSIBLE CEILING SPACES ONLY. ANY AREA WITH OUT ACCESSIBLECEILING SPACE OR CABLE TRAY SHALL HAVE ALL CABLES RUN IN CONDUIT.5.ALL CONDUIT SHALL BE RUN PARALLEL OR PERPENDICULAR TO STRUCTURE.6.EC SHALL FIRE SEAL AROUND ALL CONDUITS PENETRATING THROUGH FLOORS, ROOF, AND FIRERATED WALLS.7.IN HARD LID CEILINGS, AND AREAS WITH CEILINGS THAT ARE OPEN TO STRUCTURE. PROVIDESURFACE-MOUNTED DEVICES AND THEIR RELATED SURFACE MOUNT BACK BOXES AND SURFACEMOUNTED CONDUIT IN AREAS WITH CEILINGS THAT ARE OPEN TO STRUCTURE. PAINT EACHBACKBOX AND CONDUIT TO MATCH THE ADJACENT SURFACE.8.ROOMS AND/OR AREAS WITH EXPOSED CEILINGS SHALL HAVE ALL CABLES ROUTED IN CONDUIT.CONDUIT SHALL BE TIGHT TO STRUCTURE, ROUTED PARALLEL AND ADJACENT TO STRUCTURE,AND SHALL BE PAINTED TO MATCH ADJACENT SURFACE. SURFACE MOUNTED CONDUITS SHALLNOT BE UTILIZED IN OCCUPIED SPACES.9.WHERE OPEN CABLING IS PERMITTED BY CODE, EACH LOW VOLTAGE SYSTEM SHALL HAVE THEIRCABLES SUSPENDED SEPARATE FROM OTHER LOW VOLTAGE SYSTEMS (I.E. FIRE ALARM CABLESIN ONE J-HOOK, INTRUSION ALARM IN ANOTHER J-HOOK, AND SO ON). ALL CABLES MUST BEROUTED IN CONDUIT IN AREAS WITH EXPOSED CEILINGS. CATEGORY RATEDTELECOMMUNICATIONS CABLING FOR DATA, VOICE, IP INTERCOM/CLOCK SPEAKER, CCTV ANDACCESS CONTROL MAY SHARE THE SAME J-HOOK AND PATHWAYS. EXISTING CABLE TRAY SHALLBE UTILIZED WHENEVER POSSIBLE. IF EXISTING J-HOOK/CABLE TRAY IS ALREADY FULL, THEN NEWJ-HOOK/CABLE TRAY SYSTEM SHALL BE PROVIDED FOR WIRING THIS PROJECT.10.ALL OUTLETS, SWITCHES AND DEVICES MOUNTED BACK TO BACK IN A WALL, MUST BE SPACED AMINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE BOX TOMEET ACOUSTICAL REQUIREMENTS.11.ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTSTHROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.12.SEE THE SITE PLANS FOR ADDITIONAL WORK.13.CAMERAS SHALL BE LOCATED AS SUCH TO AVOID RESTRICTING THE CAMERAS FIELD OF VIEWFROM: EXIT SIGNS, LIGHTING, DOOR HEADERS, BUILDING FEATURES, BANNERS, OR OTHER (ART)ITEMS HANGING FROM THE CEILING. COORDINATE WITH ALL TRADES AS REQUIRED PRIOR TOROUGH-IN.14.SEE THE ACCESS CONTROL SYSTEM RISER DIAGRAM, RELATED DETAIL SHEETS, AND THEELECTRICAL LEGEND, FOR EQUIPMENT THAT IS NOT SHOWN ON THE FLOOR PLANS, BUT SHALL BEPROVIDED AND INSTALLED FOR THIS PROJECT. MOUNT ACCESS CONTROL PANEL IN ACCESSIBLECEILING SPACE AS CLOSE AS POSSIBLE TO THE DOOR THE PANEL IS CONTROLLING.15.SEE ALL DETAIL SHEETS AND RISER DIAGRAMS FOR ADDITIONAL WORK REQUIRED BY SECTIONS271500.16.ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF. COPPERTELECOMMUNICATIONS CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH. ANY RUN LENGTHSEXCEEDING 295' SHALL USE 2 STRAND MULTI-MODE FIBER OPTIC CABLE WITH MEDIA CONVERTERSON BOTH ENDS AND A POWER CONDUCTOR FROM DEDICATED POWER SUPPLY SIZED TO MEETLOAD AND DISTANCE CAPACITY OF THE CCTV CAMERA AND MEDIA CONVERTER.17.ALL MEDIA CONVERTERS MOUNTED ON POLES OR EXTERIOR APPLICATIONS SHALL BE MOUNTEDIN NEMA 4 ENCLOSURES. ACTIVE ELECTRONIC COMPONENTS ARE REQUIRED TO BE MOUNTEDABOVE GRADE AND ARE NOT ALLOWED IN HANDHOLD OR SYSTEM VAULTS.18.MOUNT EXTERIOR CAMERAS AT 12' TO 15' AFF OR AS CLOSE AS POSSIBLE TO OBTAIN BEST VIEWFROM CAMERAS. MAINTAIN CONSTANT MOUNTING HEIGHT THROUGHOUT FOR EACH CAMERA. SEECAMERA MOUNTING DETAIL SHEET FOR MORE INFORMATION. COORDINATE WITH OWNER ASREQUIRED FOR EXACT CAMERA LOCATION AND ALL MOUNTING CONFLICTS.19.FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS REQUIREDFOR ROUTING OF CONDUIT. PROVIDE SURFACE MOUNTED METAL RACEWAY PAINTED TO MATCHADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.20.ALL WORK SHALL BE DONE IN A MANOR TO MINIMIZE THE IMPACT ON PATIENT CARE. COORDINATEWITH THE VA FOR BEST WORK TIME AND ACCESS TO SPACES. ALL WORK IN PATIENT SPACESSHALL CONFORM TO VA GUIDELINES FOR CLEAN SPACE REQUIREMENTS.21.SURFACE MOUNTED CONDUIT WITHIN VAULTED CEILINGS OF BUILDING 1 IS NOT ALLOWED.CONTRACTOR SHALL ROUTE THE CABLING TO ADJACENT ROOMS TO FACILITATE CABLEINSTALLATION.MAGNETIC DOOR HOLDERW/C/CNDUPLEX RECEPTACLEJUNCTION BOX - SIZE PER CODECONSTRUCTION NOTESW INDICATES WEATHERPROOF FOR ALL DEVICES, PROVIDE LOCKING COVER ON RECEPTACLES.WALL DEVICES WITH LIGHT LINE WEIGHT INDICATES EXISTING TO BE RETAINEDALL DEVICES WITH DASH LINE INDICATES EXISTING TO BE REMOVEDDEMOLITION NOTESELEVATION CALL OUT - A INDICATES ELEVATION DETAIL IDENTIFICATION, E4.01 INDICATES SHEETELEVATION DETAIL DRAWN ON11DATA OUTLET - (1) DATA PORT AND (1) CAT6 CABLES WITH 10' SERVICE LOOP IN CLOSEST ACCESSIBLE CEILING SPACE. NUMBERINDICATES IF DIFFERENT THAN 1#HANDHOLEUNDERGROUND CONDUITEMERGENCY LOCK DOWN CONTROL BUTTONW/C/CNEXTERIOR CCTV CAMERA - 'W' INDICATES WALL MOUNT, 'C' INDICATES CEILING MOUNT, 'CN' INDICATES CORNER MOUNT.SEE THE CCTV RISER DIAGRAM AND MOUNTING DETAILS FOR ADDITIONAL REQUIREMENTS. MAINTAIN THETELECOMMUNICATIONS OUTLET REQUIREMENTS. PROVIDE (1) DATA PORT AND (1) CAT6 CABLE WITH A 10-FOOT SERVICELOOP FOR EACH CAMERA SHOWN ON THE DRAWINGS. MAINTAIN THE TELECOMMUNICATIONS OUTLET REQUIREMENTS.ACRIACPACPSCRDREXEDELDPBDOOR RELEASE PUSH BUTTONCCTV MONITOR - MOUNT AT +60" AFF UNLESS NOTED OTHERWISE. PROVIDE AS SPECIFIED.MONT-001FSECURITY LEGENDLIGHTING FIXTURESCHEDULESHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY6/25/2019 12:49:34 PM 01.23.202019024PERMITFORT STEVENS ELEMENTARY SCHOOL 16525 100th Way SE YELM, WA 98597 SECURITY UPGRADES 1/23 /20 CCCCCCCCCSEPTICDRAINFIELDSEPTICDRAINFIELDSEPTICRESERVESEPTICRESERVE8" WATERMAIN8" WATERMAINF.H.F.H.10" WATERMAIN BY OTHERS F.H.8" WATERMAIN8" WATERMAIN F.H.PROPOSEDCONNECTIONSANITARYSEWERPROPOSEDCONNECTIONSSTORM SYSTEMSS S S SSSSST ST ST STSTST STSTST STSTSTSTST190 LF 12" PERF PIPE350'BASEBALL FIELDSOFTBALL FIELDPEA GRAVEL PITPLAY AREA350'CONVERTEDPLAYSHEDEXISTINGELEMENTARYSCHOOLFF=341.0PLANTER AREA BUS PARKINGASPHALT PAVINGPARKINGMAZE GATE50' EASEMENTFOR ELEC TRANSLINEPLANTER AREAASPHALT PLAY AREASERVICE(E) PLANTER AREAEXISTINGPORTABLESFHFHFHPLANTER AREANEWPLAYSHEDNEW DOUBLEPORTABLES(E) PLANTERAREAS(E) PLANTER AREA(E) BRICK PAVEDAREAMIDDLE ROAD SELAWNLAWNLAWNP.P.P.P.P.P.OVERHEADPOWER LINEGUY WIREDISTRICTSTORAGEBUILDING9000 S.F.FRONT YARDSET BACK15'-0" TYPICALNEW TYPE ILANDSCAPINGCONCRETEWALKSGRAVEL ACCESSROADT-101FSITE PLAN -SECURITYSHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY6/25/2019 12:49:34 PM 01.23.202019024PERMITFORT STEVENS ELEMENTARY SCHOOL 16525 100th Way SE YELM, WA 98597 SECURITY UPGRADESSCALE:N1FORT STEVENS ESSITE PLAN - SECURITY1" = 50'1/23 /20 DDDDDDDDDDDCCCEDC RDELDELDMONACP ACPACP2103411PB42T-111F3T-111FMDFEXISTING IDF RACK9310910910910910911111111191CCCCNCNCN119931191115111103.2102.2153.2158154.2154.1153.1155.1156.1155.2156.2157.2148.2149.2162157.1143CREDDDCRCREDADAADAA C PJJ1135ED 91011W91066SLIESLIEEX1WL187102.2T-111FFIRST FLOOR PLAN -AREA 1 - SECURITYSHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY6/25/2019 12:49:34 PM 01.23.202019024PERMITFORT STEVENS ELEMENTARY SCHOOL 16525 100th Way SE YELM, WA 98597 SECURITY UPGRADEST-113FT-111FT-112FSCALE:N1FORT STEVENS ES -FIRST FLOOR PLAN - AREA 1 - SECURITY1/8" = 1'CONSTRUCTION NOTESPROVIDE 120 VOLT POWER CONNECTION TO ADA DOOR OPERATOR AND PUSHBUTTONS.PROVIDE A DUPLEX RECEPTACLE AND 120 VOLT POWER FOR THE MONITOR.ACCESS CONTROL PANEL / INTERFACE AND POWER SUPPLY AS SPECIFIED. MOUNTABOVE ACCESSIBLE CEILING. PROVIDE 120 VOLT CIRCUIT.PROVIDE 24 VOLT MAGNETIC DOOR HOLD OPENS. CONNECT TO ACCESS CONTROLPOWER SUPPLY.EXISTING FIRE ALARM ANNUNCIATOR.DISCONNECT AND REMOVE EXISTING WALL MOUNTED LIGHT FIXTURES. EXTENDEXISTING CIRCUIT TO NEW LIGHT LOCATIONS.PROVIDE CONNECTION OF NEW LIGHTS TO EXISTING LIGHTING CIRCUIT IN ADJACENTSPACE.PROVIDE CONNECTION TO UNSWITCHED HOT LEG FOR BATTERY PACK.PROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA, ACCESS CONTROL PANEL,AND MONITOR LOCATION.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN IDF RACK.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN MDF.123456SCALE:N2FORT STEVENS ES - ENLARGED VESTIBULE - SECURITY PLAN1/4" = 1'SCALE:N3FORT STEVENS ES - ENLARGED VESTIBULE - LIGHTING PLAN1/4" = 1'78910111/23 /20 DDDDDDDDDC1111CNCNCW21212121169.1307.1301.1306.1302.1167.2304.1169.2307.2306.2305.2301.2302.2303304.2305.1T-112FFIRST FLOOR PLAN -AREA 2 - SECURITYSHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY6/25/2019 12:49:34 PM 01.23.202019024PERMITFORT STEVENS ELEMENTARY SCHOOL 16525 100th Way SE YELM, WA 98597 SECURITY UPGRADESSCALE:N1FIRST FLOOR PLAN - AREA 2 - SECURITY PLAN1/8" = 1'T-113FT-111FT-112FCONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN MDF.121/23 /20 DDDDDDDDDDDDDDDDDCREDCCCCREDCREDCCACPACPACPACPACP11112211111111111CCNCNCWWC35135353535343434343434118.2168167.1175.2176.2176.1184.1185.1175.1187185.2142.2182.1183.2182.2181127.3200.1127.2127.1136202.2183.1147T-113FFIRST FLOOR PLAN -AREA 3 - SECURITYSHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY6/25/2019 12:49:34 PM 01.23.202019024PERMITFORT STEVENS ELEMENTARY SCHOOL 16525 100th Way SE YELM, WA 98597 SECURITY UPGRADEST-113FT-111FT-112FSCALE:N1FIRST FLOOR PLAN - AREA 3 - SECURITY1/8" = 1'CONSTRUCTION NOTESACCESS CONTROL PANEL / INTERFACE AND POWER SUPPLY AS SPECIFIED. MOUNTABOVE ACCESSIBLE CEILING. PROVIDE 120 VOLT CIRCUIT.PROVIDE 24 VOLT MAGNETIC DOOR HOLD OPENS. CONNECT TO ACCESS CONTROLPOWER SUPPLY.PROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA AND ACCESS CONTROLPANEL.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN IDF RACK.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN MDF.123451/23 /20