Loading...
2020.0026.BP0003 200128_MillPondES_PermitFLOOR FINISH TRANSITION SHEET NOTE REVISION EXTERIOR ELEVATION DETAIL CALLOUT - SECTION CUT LINE DOOR NUMBER CALLOUT WALL TYPE CALLOUT WINDOW TYPE CALLOUT LOUVER TYPE CALLOUT CENTER LINE DETAIL CALLOUT - PLAN RELITE TYPE CALLOUT STOREFRONT TYPE CALLOUT INTERIOR ELEVATION 1 A-201 1 A-591 SIM 1 A-591 SIM ELEVATION MARKER DATUM POINT NAME ELEVATION 1 BREAK LINE, ROUND VCTCPTA-211 2 3 4 1 101L1 ROOF TYPE CALLOUT ROOM NAME/NUMBER CEILING HEIGHT SLOPE INDICATOR GRAPHIC SCALE SLOPE 6:12 12 6 SCALE: 0 4 8 16 1/8" = 1'-0" 11'-0" ROOM NAME 101 FLOOR/CEILING TYPE CALLOUT WALL SECTION BUILDING SECTION 1 A-311 A A-301 A A-301 6W1 R1 FC1 CLCL PLAN NORTH NORTH ARROW TRUE NORTH R1 SF1 1 SHEET NOTE - DEMOLITION1 W1 TRUE NORTH SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:06:40 PMG-101M 1.23.2020 19024.03 INDEX SHEET, PROJECT INFORMATION, PROJECT TEAM PERMITMILL POND ELEMENTARY909 MILL ROAD SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1YELM COMMUNITY SCHOOLS OWNER 107 1ST STREET N YELM, WA 98597 BCRA, INC ARCHITECT 2106 PACIFIC AVENUE, SUITE 300 TACOMA, WA 98402 CONTACT: HEATHER HOCKLANDER PHONE: 253.627.4367 PCS STRUCTURAL SOLUTIONS STRUCTURAL 1250 PACIFIC AVENUE, SUITE 701 TACOMA, WA 98402 CONTACT: WES NEELEY PHONE: 253.383.2797 YELM COMMUNITY SCHOOLS OWNERS REP PO BOX 476 YELM, WA 98597 CONTACT: KASEY WYATT PHONE: 360.458.1900 BCE ENGINEERS ELECTRICAL 6021 12th ST. EAST, SUITE 200 FIFE, WA 98424 CONTACT: CARRIE TAYLOR PHONE: 253.922.0446 GENERAL G-101M INDEX SHEET, PROJECT INFORMATION, PROJECT TEAM A-111M SITE PLAN A-121M FIRST FLOOR PLAN - OVERALL A-401M ENLARGED VIEWS A-501M DETAILS A-611M DOOR SCHEDULE & WALL ASSEMBLIES NUMBER SHEET DRAWING DESCRIPTION ARCHITECTURAL VICINITY MAP SHEET INDEX PROJECT TEAM ABBREVIATIONS ARCHITECTURAL SYMBOLS PROJECT INFORMATION AFF ABOVE FINISHED FLOOR CG CORNER GUARD DS DOWNSPOUT EQ EQUAL FV FIELD VERIFY GA GAUGE GWB GYPSUM BOARD MAX MAXIMUM MDF MEDIUM DENSITY FIBERBOARD MIN MINIMUM NIC NOT IN CONTRACT OC ON CENTER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OPP OPPOSITE PPT PRESSURE PRESERVATIVE TREATED SIM SIMILAR TB TACKBOARD TYP TYPICAL UNO UNLESS NOTED OTHERWISE WB WHITEBOARD SITE ADDRESS 909 MILL ROAD SE, YELM, WA 98597 PARCEL NO. 21725140100 JURISDICTION CITY OF YELM SCOPE OF WORK SAFETY AND SECURITY UPGRADES TO THE EXISTING SCHOOL, INCLUDING: NEW SECURITY VESTIBULE, ACCESS CONTROL SYSTEM ON DOORS, CCTV SYSTEM, MODIFICATIONS TO EXISTING LIGHTING AND FIRE SPRINKLER AS REQUIRED TO ACCOMMODATE NEW VESTIBULE. MILL POND ELEMENTARY 909 MILL RD SE YELM, WA 98597 PERMIT - 1.23.2020 ADAMS CONSULTING DOOR HARDWARE 2337 N 57TH ST SEATTLE, WA 98103 CONTACT: GORDON ADAMS PHONE: 206.528.0244 TELECOM T-001M SECURITY LEGEND LIGHTING FIXTURE SCHEDULE T-101M SITE PLAN - SECURITY T-111M FIRST FLOOR PLAN - AREA 1 - SECURITY T-112M FIRST FLOOR PLAN - AREA 2 - SECURITY T-113M FIRST FLOOR PLAN - AREA 3 - SECURITY SAFETY & SECURITY IMPROVEMENTS 1 CODE INFORMATION OCCUPANCY GROUPS: PRIMARY: EDUCATIONAL (E) PER 305.1, STUDENTS THROUGH 12TH GRADE OTHER: ASSEMBLY (A-3) PER 303.1.3, ASSEMBLY AREA ACCESSORY TO GROUP E ARE NOT CONSIDERED A SEPARATE OCCUPANCY. CONSTRUCTION TYPE: E OCCUPANCY AREA: TYPE VB, FULLY SPRINKLERED A-3 OCCUPANCY AREA: TYPE VA, FULLY SPRINKLERED EGRESS: NO CHANGES TO EXISTING EXITING CAPACITY BUILDING WALLS: ABOVE GRADE, WOOD FRAMED: R-VALUE: R-21 VERTICAL FENESTRATION: METAL FRAMING, FIXED: U-FACTOR: 0.38 METAL FRAMING, ENTRACE DOORS: U-FACTOR: 0.60 LIGHTING: NO MORE THAN 50 PERCENT OF THE LUMINAIRES ARE BEING REPLACED. NEW LUMINAIRES ARE REDUCED WATTAGE LED TYPE IN ACCORDANCE WITH C503.6. ENERGY MECHANICAL M-001 FIRST FLOOR MECHANICAL PLAN FIRE SPRINKLER, FIRESTOPPING DEFERRED SUBMITTALS SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:06:37 PMA-111M 1.23.2020 19024.03 SITE PLAN PERMITMILL POND ELEMENTARY909 MILL ROAD SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1Reviewer TRUE NORTH N.T.S.1 SITE PLAN - FOR REFERENCE ONLY DWDF DFDF16.522.303.203.123.230.268.267.269.272.2 73.2 84.2 75.277.285.2 5986.287.288.2 51.2 50.249.247.237.2 46.244.239.20105.2 15.216.316.4 36.204.2 58 02.1 02.2 A-401M 300A-401M 1 17.1 04.1 2-HR RATED WALL 2-HR RATED WALL 1. ALL DOORS ARE EXISTING TO REMAIN U.N.O. PROTECT FROM DAMAGE DURING SCOPE OF WORK.00.000.0NEW DOOR NOTE:NOT ALL LEGEND ITEMS MAY BE PRESENT ON THIS SHEET NEW RELITE / WINDOW NEW WALL NEW WALL EXISTING RELITE / WINDOW EXISTING DOOR EXISTING WALL EXISTING WALL EXISTING DOOR RECIEVING UPDATES EXISTING WALL 2-HR RATED WALL, REFER TO DETAIL 3/A-501M 1-HR RATED AREA, REFER TO DETAIL 3/A-501M SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:06:37 PMA-121M 1.23.2020 19024.03 FIRST FLOOR PLAN - OVERALL PERMITMILL POND ELEMENTARY909 MILL ROAD SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 11/16" = 1'-0"1 FIRST FLOOR PLAN - OVERALL FLOOR PLAN GENERAL NOTESFLOOR PLAN LEGEND 0 8 16 32 1/16" = 1'-0" SCALE: PLAN NORTH 0105.2 36.204.2 A-401M 3 A-401M4 005 A-401M EXISTING MASONRY VENEER EXTERIOR WALLS, TYP. NEW ALUMINUM STOREFRONT 04.1 3'-6"DEMOLISH EXISTING HANDRAIL BUILT-UP STUD AT JAMB, (2) 2X6 FULL HEIGHT AND (2) 2X6 CRIPPLES VESTIBULE EXISTING CONCRETE SLAB ON GRADE. PREP EXISTING CONCRETE SURFACE FOR WALK OFF MAT, CUT OUT EXISTING FIBEROUS ASPHALT EXPANSION JOINTS, FILL WITH CEMENTITIOUS UNDERLAYMENT SAWCUT AND REMOVE EXISTING CONCRETE SLAB ON GRADE AS REQUIRED FOR NEW FOOTING A-501M 5 RELOCATED KNOX BOX FROM INSIDE NEW VESTIBULE WALL, PATCH AND REPAIR BRICK FROM REMOVAL 1. ALL DOORS ARE EXISTING TO REMAIN U.N.O. PROTECT FROM DAMAGE DURING SCOPE OF WORK. 5 A-401M REMOVE EXISTING PLYWOOD SOFFIT AS REQUIRED TO INSTALL WOOD BACKING FOR SECURING TOP OF EXTERIOR WALL PATCH OPENINGS IN SOFFIT TO MATCH EXISTING, PAINT TO MATCH EXISTINGRIDGEEXISTING LIGHT FIXTURE, TYP. EXISTING FIRE SPRINKLER HEAD, TYP. LIGHT FIXTURE - REFER ALSO TO ELECTRICAL NEW DOOR AS SCHEDULED / OPENING, PER PLAN EXISTING WALL TO REMAIN EXISTING DOOR/OPENING TO REMAIN EXISTING RELITE / WINDOW TO REMAIN NEW RELITE / WINDOW / STOREFRONT AS SCHEDULED NEW WALL PER PLAN 1. - RELOCATED DEDICATION PLAQUE FROM OUTSIDE NEW VESTIBULE WALL, PATCH AND REPAIR BRICK FROM REMOVAL DEMOLISH EXISTING HM FRAME SAWCUT SILL FOR NEW DOOR; PATCH DRYWALL AT INTERIOR; PROVIDE ALUMINUM THRESHOLD(S) SPANNING FROM LOBBY FLOOR FINISH TO WALK-OFF MAT HOLLOW METAL FRAME AND RELITE ROUGH OPENING MATCH EXISTING ROUGH OPENINGMATCH EXISTINGSALAVGE BRICK AT DEMO FOR REUSE AT JAMBS FIBER CEMENT SIDING, 6" EXPOSURE FIBER CEMENT TRIM, 6" WIDTH ALUMINUM STOREFRONT 5 A-401M SF-1 5 A-501M 4 A-501M 4 A-501M 6 A-501M 6W1 THICKENED SLAB FOOTING 6x12 HEADER 2x6 TOP PLATE, REMOVE AND PATCH SOFFIT TO ADD BLOCKING BETWEEN EXISTING STRUCTURE A-501M 1 A-501M 2 NEW DOOR NOTE:NOT ALL LEGEND ITEMS MAY BE PRESENT ON THIS SHEET NEW RELITE / WINDOW NEW WALL NEW WALL EXISTING RELITE / WINDOW EXISTING DOOR EXISTING WALL EXISTING WALL EXISTING DOOR RECIEVING UPDATES EXISTING WALL00.000.0DEMOLISH RELITE / WINDOW DEMOLISH EXISTING WALL DEMOLISH EXISTING DOOR DEMOLISH EXISTING WALL SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:06:38 PMA-401M 1.23.2020 19024.03 ENLARGED VIEWS PERMITMILL POND ELEMENTARY909 MILL ROAD SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1Author 1/4" = 1'-0"1 FLOOR PLAN - VESTIBULE 0 2 4 8 1/4" = 1'-0" SCALE: PLAN NORTH FLOOR PLAN GENERAL NOTES FLOOR PLAN LEGEND 1/4" = 1'-0"2 REFLECTED CEILING PLAN - VESTIBULE REFLECTED CEILING PLAN GENERAL NOTES REFLECTED CEILING PLAN LEGEND 1/4" = 1'-0"4 INTERIOR ELEVATION 1/4" = 1'-0"3 EXTERIOR ELEVATION 1/4" = 1'-0"5 EXTERIOR VESTIBULE WALL SECTION ROOM FINISH SCHEDULE ROOM NAME BASE FLOOR NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING COMMENTSMATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH VESTIBULE RB FF EX WOM EX EX EX EX GWB PT EX EX EX EX 18" WIDE X 18" TALL THICKENED SLAB FOOTING WITH (2) #5 TOP AND BOTTOM 3" MIN.TYP.3" CLR,TYP. 3" CLR, CONTINUOUS SILL GASKET SAWCUT AND REMOVE EXISTING CONCRETE SLAB ON GRADE AS REQUIRED FOR NEW FOOTING BUILT-UP COLUMN PRESSURE-TREATED SILL PLATE BACKER ROD AND SEALANT SEAL AIR/WATER BARRIER TO CONCRETE AND SILL PLATE WATERTIGHT (AIR BARRIER) CONTINUOUS 1-3/4" LVL BETWEEN WALL AND RIDGE, RIP WIDTH TO FIT BETWEEN EXISTING ROOF FRAMING 16d AT 12" O.C., TYP 16d AT 8" O.C., STAGGER 2X6 TOP PLATE INTERIOR EXTERIOR BACKER ROD AND SEALANT PREFINISHED SHEET METAL TRIM SET IN CONTINUOUS SEALANT BACKER ROD AND SEALANT SEAL WITH SPRAY FOAM SEALANT SEALANT SHIM AS REQUIRED ALUMINUM STOREFRONT PER ELEVATIONS SHIM AS REQUIRED EXISTING WALL ASSEMBLY PER PLAN SELF ADHERED FLASHING SEALANT AIR/WATER BARRIER (AIR BARRIER) FIBER CEMENT TRIM 6"FIBER CEMENT SIDING PER ELEVATIONS SHEET METAL FLASHING 4/4 X 6" FIBER CEMENT TRIM PREFINISHED SHEET METAL COUNTER FLASHING PRIMARY SEALANT (AIR BARRIER) LIQUID FLASHING (AIR BARRIER) ALUMINUM CURTAINWALL PER ELEVATIONS EXTERIORINTERIOR 6"1/2"CONTINUOUS PLASTIC VENT STRIP ALONG BOTTOM EDGE OF PLASTIC BATTENS WRAP SELF ADHERED MEMBRANE FULL PERIMETER OF OPENING, TYP (AIR BARRIER) PREFINISHED SHEET METAL HEAD FLASHING SECONDARY SEALANT (AIR BARRIER) WALL TYPE PER PLAN AIR & WATER BARRIER OVER HEAD FLASHING (AIR BARRIER) 6X12 HEADER MULLION BEYOND DOOR - REFER TO SCHEDULE ADA ACCESSIBLE THRESHOLD, SET IN CONTINUOUS BED OF BUTYL SEALANT WALL BEYOND EXTERIORINTERIOR STOREFRONT PER SCHEDULE WITH SUBSILL SET IN CONTINUOUS BED OF SEALANT FINISH AS SCHEDULED OVER EXISTING CONCRETE SLAB EXISTING WALL ASSEMBLY HM FRAME SEALANT SPRAY FOAM ALIGN AT 'SIM', SAWCUT BRICK AS REQUIRED FOR NEW HM DOOR FRAME DOOR (GLAZING AT 'OPP') FINISH AS SCHEDULED OVER EXISTING CONCRETE SLAB DOOR AND FRAME PER SCHEDULE ADA ACCESSIBLE ALUMINUM THRESHOLD, SPANNING FROM LOBBY FLOOR FINISH TO WALK- OFF MAT, SET IN CONTINUOUS BED OF BUTYL SEALANT EXPANSION JOINT MATERIAL FINISH AS SCHEDULED OVER EXISTING CONCRETE SLAB SEALANT SPRAY FOAM HM FRAME EXISTING WALL ASSEMBLY EXISTING WALL ASSEMBLY HM FRAME SEALANT SPRAY FOAM ALIGNWALL NEW CONDUIT UL APPROVED AND TESTED SEALANT TO COMPLETELY FILL ANNULAR SPACE, PAINT TO MATCH ADJACENT AT EXPOSED TO VIEW CONDITIONS INTERIOR CONDITIONS: SEAL ANY PENETRATIONS THROUGH WALLS WITH FIRESTOPPING TO MAINTAIN EXISTING FIRE AND ACOUSTIC RATING OF WALL EXTERIOR CONDITIONS: SEALANT AS SPECIFIED IN SECTION 07 9000 SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:06:39 PMA-501M 1.23.2020 19024.03 DETAILS PERMITMILL POND ELEMENTARY909 MILL ROAD SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 11 1/2" = 1'-0"1 FOOTING 1 1/2" = 1'-0"2 TOP OF WALL 3" = 1'-0"5 STOREFRONT JAMB 3" = 1'-0"6 STOREFRONT HEAD 3" = 1'-0"4 STOREFRONT THRESHOLD AND SILL 3" = 1'-0"8 HM DOOR JAMB 3" = 1'-0"7 HM DOOR THRESHOLD 3" = 1'-0"9 HM DOOR HEAD 3" = 1'-0"11 HM FRAME SILL 3" = 1'-0"3 TYPICAL CONDUIT PENETRATION GL-1 1" INSULATED TEMPERED GLASS GL-2 1/4" TEMPERED GLASS 1. FIELD VERIFY ALL DOOR/FRAME OPENING SIZES. ASSEMBLY TYPE AND DESCRIPTION ASSEMBLY COMPONENTS - PLAN VIEW RATED ASSEMBLY REQUIREMENTS REFER TO G-201 FOR LOCATIONS OF WALLS REQUIRING FIRE-RATED CONSTRUCTION EXTERIOR 2X6 WOOD STUD WALL ASSEMBLY 6W1 SCALE: 1 1/2" = 1'-0" FIBER CEMENT LAP SIDING AIR/WATER BARRIER (AIR BARRIER) 1/2" PLYWOOD SHEATHING 2X6 WOOD FRAMING @ 16" OC, WITH R-21 BATT INSULATION 5/8" TYPE 'X' GYPSUM BOARD, WITH CLASS III VAPOR RETARDER PAINT INTERIOR EXTERIOR FINISH FLOOR FRAME: ALUMINUM FINISH: CLEAR ANNODIZED GLAZING: GL-1 PROJECTION: NONE SHADING: NONE 7'-2"EQ EQ SCHEDULE PER SF-1 EQEQEQEQ1 FINISH FLOOR ROUGH OPENING MATCH EXISTING ROUGH OPENINGMATCH EXISTINGEQEQSCHEDULE PER 7 A-501M 11 A-501M 8 A-501M 9 A-501M 8 A-501M 8 A-501M SIM OPP FINISH FLOOR A 6"6"36"6"24"12"PER SCH PER SCHSHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:06:40 PMA-611M 1.23.2020 19024.03 DOOR SCHEDULE & WALL ASSEMBLIES PERMITMILL POND ELEMENTARY909 MILL ROAD SEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1DOOR SCHEDULE - MILL POND DOOR NUMBER DOOR FRAME DETAIL CALLOUT FIRE RATING LABEL HARDWARE GROUP REMARKS DOOR NUMBER WIDTH HEIGHT DEPTH TYPE MATERIAL FINISH GLAZING TYPE MATERIAL FINISH HEAD JAMB SILL00 6' - 0" 7' - 0" 1 3/4" A AL FF GL-1 SF-1 AL FF 18 B 00 01 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B, C 01 02.1 4' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 02.1 02.2 4' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 02.2 03.1 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 19 B 03.1 03.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 03.2 04.1 3' - 0" 7' - 0" 1 3/4" A HM PT GL-2 1 HM PT ## 04.1 04.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 04.2 05.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 05.2 15.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 15.2 16.3 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 16.3 16.4 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 16.4 16.5 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 16.5 17.1 3' - 6" 7' - 0" 1 3/4" EX HM EX EX HM EX 17.1 22.3 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 22.3 23.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 23.2 30.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 30.2 36.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 36.2 37.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 37.2 39.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 39.2 44.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 44.2 46.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 46.2 47.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 47.2 49.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 49.2 50.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 50.2 51.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 51.2 58 8' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX A,B 58 59 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 59 67.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 67.2 68.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 68.2 69.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 69.2 72.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 72.2 73.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 73.2 75.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 75.2 77.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 77.2 84.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 84.2 85.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 85.2 86.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 86.2 87.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 87.2 88.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 88.2 DOOR SCHEDULE GENERAL NOTES DOOR SCHEDULE REMARKS DOOR SCHEDULE ABBREVIATIONS AL ALUMINUM EX EXISTING FF FACTORY FINISH GL-# GLAZING TYPE HM HOLLOW METAL PT PAINT ST STAIN WD WOOD A. PROVIDE MAGNETIC HOLD OPEN B. PAIR OF DOORS C. REMOVE EXISTING WEATHERSTRIPPING GLAZING TYPES 1/4" = 1'-0"3 STOREFRONT TYPES 1/4" = 1'-0"2 DOOR FRAME TYPES 1/4" = 1'-0"1 DOOR TYPES 0 1 - 2 3 - 2 02 0 SYMBOLDESCRIPTIONSECURITY LEGENDCINTERIOR CCTV CAMERA - 'W' INDICATES WALL MOUNT, 'C' INDICATES CEILING MOUNT, 'CN' INDICATES CORNER MOUNT. SEETHE CCTV RISER DIAGRAM AND MOUNTING DETAILS FOR ADDITIONAL REQUIREMENTS. MAINTAIN THETELECOMMUNICATIONS OUTLET REQUIREMENTS. PROVIDE (1) DATA PORT AND (1) CAT6 CABLE WITH A 10-FOOT SERVICELOOP FOR EACH CAMERA SHOWN ON THE DRAWINGS. MAINTAIN THE TELECOMMUNICATIONS OUTLET REQUIREMENTS.PROXIMITY CARD READER - WALL MOUNT. (M INDICATES MULLION MOUNT). SEE ACCESS CONTROL RISER DIAGRAM AND RELATED DETAILS FOR MOREINFORMATION. MOUNT AT +48" UNLESS NOTED OTHERWISE.DOOR POSITION SWITCH (A DPDT SHALL BE PROVIDED AT EACH LOCATION SHOWN). CONNECT EXISTING INTRUSION CABLINGTO THE NEW DPDT SWITCH. PROVIDE NEW CABLING FOR ACCESS CONTROL MONITORING.ACCESS CONTROL READER I/O INTERFACE - WALL MOUNT ABOVE ACCESSIBLE CEILING SPACE - PROVIDE CABLING TO THENEAREST ACCESS CONTROL PANEL. SEE ACCESS CONTROL RISER DIAGRAM AND RELATED DETAILS FOR MOREINFORMATION.REQUEST TO EXIT - REX SHALL BE INTEGRAL TO THE DOOR HARDWARE AND PROVIDED BY DIVISION 8. PROVIDE NECESSARYCABLING FROM ACP/ ACRI AT EACH LOCATION.ACCESS CONTROL SYSTEM POWER SUPPLYELECTRIFIED EXIT DEVICE - SHOWN FOR REFERENCE ONLY. COORDINATE WITH DOOR HARDWARE FOR EXACT DEVICE AT EACHLOCATION.CACCESS CONTROL PANEL - MOUNTED ABOVE ACCESSIBLE CEILING SPACE. PROVIDE (1) DATA PORT AND (1) CAT6 CABLEWITH A 10-FOOT SERVICE LOOP AT EACH LOCATION. SEE ACCESS CONTROL RISER DIAGRAM AND RELATED DETAILS FORMORE INFORMATION.1.EXISTING ANALOG CCTV SYSTEM IN BUILDING 1 IS TO REMAIN FULLY OPERATIONAL UNTIL NEW IPCCTV SYSTEM IN BUILDING 1 IS FULLY OPERATIONAL. EXISTING ANALOG CCTV SYSTEM TOINCLUDE OLD CCTV CABLING SHALL BE DEMOLISHED AFTER THE VA HAS APPROVED THE NEW IPCCTV SYSTEM. TURN OVER ALL OLD CCTV DEVICES TO THE OWNER. PROVIDE NEW CEILING TILESAS REQUIRED. PATCH ANY WALL AND CEILING SURFACES IN HARD LID AREAS WHERE ANY OLDCAMERAS WHERE INSTALLED. PAINT TO MATCH ADJACENT SURFACE.2.SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR SHEET.3.REVIEW PLANS FOR LOCATIONS OF AREAS WITH ACCESSIBLE CEILING TILES, GWB, AND OPENCEILINGS. PROVIDE MANUFACTURER APPROVED BACK BOXES IN AREAS WITH CEILINGS THAT AREOPEN TO STRUCTURE. ALL CABLE/CONDUIT ROUTING SHALL USE THE EXISTING CORRIDORS ASTHE MAIN ROUTING PATH AS MUCH AS POSSIBLE BEFORE CROSSING INTO OTHER AREAS TO GETTO DEVICE/IDF LOCATIONS. LINE OF SIGHT ROUTING OF THE CABLE/CONDUITS WILL NOT BEACCEPTABLE.4.UTILIZE EXISTING CABLING TRAY WHEN EVER POSSIBLE IN BUILDINGS WITH CABLE TRAY. OPENCABLING IS ACCEPTABLE IN ACCESSIBLE CEILING SPACES ONLY. ANY AREA WITH OUT ACCESSIBLECEILING SPACE OR CABLE TRAY SHALL HAVE ALL CABLES RUN IN CONDUIT.5.ALL CONDUIT SHALL BE RUN PARALLEL OR PERPENDICULAR TO STRUCTURE.6.EC SHALL FIRE SEAL AROUND ALL CONDUITS PENETRATING THROUGH FLOORS, ROOF, AND FIRERATED WALLS.7.IN HARD LID CEILINGS, AND AREAS WITH CEILINGS THAT ARE OPEN TO STRUCTURE. PROVIDESURFACE-MOUNTED DEVICES AND THEIR RELATED SURFACE MOUNT BACK BOXES AND SURFACEMOUNTED CONDUIT IN AREAS WITH CEILINGS THAT ARE OPEN TO STRUCTURE. PAINT EACHBACKBOX AND CONDUIT TO MATCH THE ADJACENT SURFACE.8.ROOMS AND/OR AREAS WITH EXPOSED CEILINGS SHALL HAVE ALL CABLES ROUTED IN CONDUIT.CONDUIT SHALL BE TIGHT TO STRUCTURE, ROUTED PARALLEL AND ADJACENT TO STRUCTURE,AND SHALL BE PAINTED TO MATCH ADJACENT SURFACE. SURFACE MOUNTED CONDUITS SHALLNOT BE UTILIZED IN OCCUPIED SPACES.9.WHERE OPEN CABLING IS PERMITTED BY CODE, EACH LOW VOLTAGE SYSTEM SHALL HAVE THEIRCABLES SUSPENDED SEPARATE FROM OTHER LOW VOLTAGE SYSTEMS (I.E. FIRE ALARM CABLESIN ONE J-HOOK, INTRUSION ALARM IN ANOTHER J-HOOK, AND SO ON). ALL CABLES MUST BEROUTED IN CONDUIT IN AREAS WITH EXPOSED CEILINGS. CATEGORY RATEDTELECOMMUNICATIONS CABLING FOR DATA, VOICE, IP INTERCOM/CLOCK SPEAKER, CCTV ANDACCESS CONTROL MAY SHARE THE SAME J-HOOK AND PATHWAYS. EXISTING CABLE TRAY SHALLBE UTILIZED WHENEVER POSSIBLE. IF EXISTING J-HOOK/CABLE TRAY IS ALREADY FULL, THEN NEWJ-HOOK/CABLE TRAY SYSTEM SHALL BE PROVIDED FOR WIRING THIS PROJECT.10.ALL OUTLETS, SWITCHES AND DEVICES MOUNTED BACK TO BACK IN A WALL, MUST BE SPACED AMINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE BOX TOMEET ACOUSTICAL REQUIREMENTS.11.ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTSTHROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.12.SEE THE SITE PLANS FOR ADDITIONAL WORK.13.CAMERAS SHALL BE LOCATED AS SUCH TO AVOID RESTRICTING THE CAMERAS FIELD OF VIEWFROM: EXIT SIGNS, LIGHTING, DOOR HEADERS, BUILDING FEATURES, BANNERS, OR OTHER (ART)ITEMS HANGING FROM THE CEILING. COORDINATE WITH ALL TRADES AS REQUIRED PRIOR TOROUGH-IN.14.SEE THE ACCESS CONTROL SYSTEM RISER DIAGRAM, RELATED DETAIL SHEETS, AND THEELECTRICAL LEGEND, FOR EQUIPMENT THAT IS NOT SHOWN ON THE FLOOR PLANS, BUT SHALL BEPROVIDED AND INSTALLED FOR THIS PROJECT. MOUNT ACCESS CONTROL PANEL IN ACCESSIBLECEILING SPACE AS CLOSE AS POSSIBLE TO THE DOOR THE PANEL IS CONTROLLING.15.SEE ALL DETAIL SHEETS AND RISER DIAGRAMS FOR ADDITIONAL WORK REQUIRED BY SECTIONS271500.16.ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF. COPPERTELECOMMUNICATIONS CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH. ANY RUN LENGTHSEXCEEDING 295' SHALL USE 2 STRAND MULTI-MODE FIBER OPTIC CABLE WITH MEDIA CONVERTERSON BOTH ENDS AND A POWER CONDUCTOR FROM DEDICATED POWER SUPPLY SIZED TO MEETLOAD AND DISTANCE CAPACITY OF THE CCTV CAMERA AND MEDIA CONVERTER.17.ALL MEDIA CONVERTERS MOUNTED ON POLES OR EXTERIOR APPLICATIONS SHALL BE MOUNTEDIN NEMA 4 ENCLOSURES. ACTIVE ELECTRONIC COMPONENTS ARE REQUIRED TO BE MOUNTEDABOVE GRADE AND ARE NOT ALLOWED IN HANDHOLD OR SYSTEM VAULTS.18.MOUNT EXTERIOR CAMERAS AT 12' TO 15' AFF OR AS CLOSE AS POSSIBLE TO OBTAIN BEST VIEWFROM CAMERAS. MAINTAIN CONSTANT MOUNTING HEIGHT THROUGHOUT FOR EACH CAMERA. SEECAMERA MOUNTING DETAIL SHEET FOR MORE INFORMATION. COORDINATE WITH OWNER ASREQUIRED FOR EXACT CAMERA LOCATION AND ALL MOUNTING CONFLICTS.19.FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS REQUIREDFOR ROUTING OF CONDUIT. PROVIDE SURFACE MOUNTED METAL RACEWAY PAINTED TO MATCHADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.20.ALL WORK SHALL BE DONE IN A MANOR TO MINIMIZE THE IMPACT ON PATIENT CARE. COORDINATEWITH THE VA FOR BEST WORK TIME AND ACCESS TO SPACES. ALL WORK IN PATIENT SPACESSHALL CONFORM TO VA GUIDELINES FOR CLEAN SPACE REQUIREMENTS.21.SURFACE MOUNTED CONDUIT WITHIN VAULTED CEILINGS OF BUILDING 1 IS NOT ALLOWED.CONTRACTOR SHALL ROUTE THE CABLING TO ADJACENT ROOMS TO FACILITATE CABLEINSTALLATION.MAGNETIC DOOR HOLDERW/C/CNDUPLEX RECEPTACLEJUNCTION BOX - SIZE PER CODECONSTRUCTION NOTESW INDICATES WEATHERPROOF FOR ALL DEVICES, PROVIDE LOCKING COVER ON RECEPTACLES.WALL DEVICES WITH LIGHT LINE WEIGHT INDICATES EXISTING TO BE RETAINEDALL DEVICES WITH DASH LINE INDICATES EXISTING TO BE REMOVEDDEMOLITION NOTESELEVATION CALL OUT - A INDICATES ELEVATION DETAIL IDENTIFICATION, E4.01 INDICATES SHEETELEVATION DETAIL DRAWN ON11DATA OUTLET - (1) DATA PORT AND (1) CAT6 CABLES WITH 10' SERVICE LOOP IN CLOSEST ACCESSIBLE CEILING SPACE. NUMBERINDICATES IF DIFFERENT THAN 1#HANDHOLEUNDERGROUND CONDUITEMERGENCY LOCK DOWN CONTROL BUTTONW/C/CNEXTERIOR CCTV CAMERA - 'W' INDICATES WALL MOUNT, 'C' INDICATES CEILING MOUNT, 'CN' INDICATES CORNER MOUNT.SEE THE CCTV RISER DIAGRAM AND MOUNTING DETAILS FOR ADDITIONAL REQUIREMENTS. MAINTAIN THETELECOMMUNICATIONS OUTLET REQUIREMENTS. PROVIDE (1) DATA PORT AND (1) CAT6 CABLE WITH A 10-FOOT SERVICELOOP FOR EACH CAMERA SHOWN ON THE DRAWINGS. MAINTAIN THE TELECOMMUNICATIONS OUTLET REQUIREMENTS.ACRIACPACPSCRDREXEDELDPBDOOR RELEASE PUSH BUTTONCCTV MONITOR - MOUNT AT +60" AFF UNLESS NOTED OTHERWISE. PROVIDE AS SPECIFIED.MONSHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024MILL POND ELEMENTARY SCHOOL 909 MILL RD SE YELM, WA 98597 SECURITY UPGRADES PERMITSECURITY LEGENDLIGHTING FIXTURESCHEDULET-001M1/23 /20 CCCCCCC CSHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024MILL POND ELEMENTARY SCHOOL 909 MILL RD SE YELM, WA 98597 SECURITY UPGRADES PERMITT-101MSITE PLAN - SECURITYSCALE:N1SITE PLAN - SECURITY1" = 30'1/23 /20 DF DF DFDDDDDDDDDDDDDDDDDDDDCRCRCRCCCCCADAEDEDDCRADAEDEDEDC RELDPBPBELDMON3ACP ACPACPACPACPJJ5511166IC24124124141414141414141414142411111111111111124CNCNCNCNWWCCCONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTVCAMERA, ACCESS CONTROL PANEL, AND MONITORLOCATION.ACCESS CONTROL PANEL / INTERFACE AND POWERSUPPLY AS SPECIFIED. MOUNT ABOVE ACCESSIBLECEILING SPACE. PROVIDE 120 VOLT CIRCUIT.PROVIDE A DUPLEX RECEPTACLE AND 120 VOLTPOWER FOR THE MONITOR.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL INMEZZANINE MDF.PROVIDE 120 VOLT POWER CONNECTION TO ADA DOOROPERATOR & PUSH BUTTONS.PROVIDE 24 VOLT MAGNETIC DOOR HOLD OPENS.CONNECT TO ACCESS CONTROL POWER SUPPLY.PROVIDE CONNECTION OF NEW LIGHTS TO EXISTINGLIGHTING CIRCUIT IN SPACE.PROVIDE CONNECTION TO UNSWITCHED HOT LEG FORBATTERY PACK.12345678DEMOLITION NOTESRELOCATE EXISTING RECEPTACLE TO NEW LOCATION.EXTEND EXISTING CIRCUIT.RELOCATE EXISTING LIGHTING FIXTURE TO NEWLOCATION. EXTEND EXISTING CIRCUIT.12EX1SL1ESL1E7812SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024MILL POND ELEMENTARY SCHOOL 909 MILL RD SE YELM, WA 98597 SECURITY UPGRADES PERMITFIRST FLOOR PLAN -AREA 1 - SECURITYSCALE:N1FIRST FLOOR PLAN - AREA 1 - SECURITY1/8" = 1'T-113MT-112MT-111MT-111MSCALE:21/8" = 1'ENLARGED VESTIBULE - LIGHTING PLAN1/23 /20 DWDDDDDDDDDC11CNC1212MDF IN MEZZANINECONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA, ACCESS CONTROL PANEL,AND MONITOR LOCATION.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN MEZZANINE MDF.12SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024MILL POND ELEMENTARY SCHOOL 909 MILL RD SE YELM, WA 98597 SECURITY UPGRADES PERMITFIRST FLOOR PLAN -AREA 2 - SECURITYSCALE:N1FIRST FLOOR PLAN - AREA 2 - SECURITY1/8" = 1'T-113MT-112MT-111MT-112M1/23 /20 DDDDDDDDDDCRHIGH MOUNTEDDACP11111CNCNW23131313CONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA, ACCESS CONTROL PANEL,AND MONITOR LOCATION.ACCESS CONTROL PANEL / INTERFACE AND POWER SUPPLY AS SPECIFIED. MOUNTABOVE ACCESSIBLE CEILING SPACE. PROVIDE 120 VOLT CIRCUIT.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN MEZZANINE MDF.123SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024MILL POND ELEMENTARY SCHOOL 909 MILL RD SE YELM, WA 98597 SECURITY UPGRADES PERMITFIRST FLOOR PLAN -AREA 3 - SECURITYT-113MT-112MT-111MSCALE:N1FIRST FLOOR PLAN - AREA 3 - SECURITY1/8" = 1'T-113M1/23 /20