Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2020.0027.BP0004 200128_YelmHS_Permit
FLOOR FINISH TRANSITION SHEET NOTE REVISION EXTERIOR ELEVATION DETAIL CALLOUT - SECTION CUT LINE DOOR NUMBER CALLOUT WALL TYPE CALLOUT WINDOW TYPE CALLOUT LOUVER TYPE CALLOUT CENTER LINE DETAIL CALLOUT - PLAN RELITE TYPE CALLOUT STOREFRONT TYPE CALLOUT INTERIOR ELEVATION 1 A-201 1 A-591 SIM 1 A-591 SIM ELEVATION MARKER DATUM POINT NAME ELEVATION 1 BREAK LINE, ROUND VCTCPTA-211 2 3 4 1 101L1 ROOF TYPE CALLOUT ROOM NAME/NUMBER CEILING HEIGHT SLOPE INDICATOR GRAPHIC SCALE SLOPE 6:12 12 6 SCALE: 0 4 8 16 1/8" = 1'-0" 11'-0" ROOM NAME 101 FLOOR/CEILING TYPE CALLOUT WALL SECTION BUILDING SECTION 1 A-311 A A-301 A A-301 6W1 R1 FC1 CLCL PLAN NORTH NORTH ARROW TRUE NORTH R1 SF1 1 SHEET NOTE - DEMOLITION1 W1 TRUE NORTH SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:08:57 PMG-101H 1.23.2020 19024.03 INDEX SHEET, PROJECT INFORMATION, PROJECT TEAM PERMITYELM HIGH SCHOOL1315 W YELM AVEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1GENERAL G-101H INDEX SHEET, PROJECT INFORMATION, PROJECT TEAM A-011H SITE PLAN A-111H FIRST FLOOR PLAN - AREA 100 A-121H SECOND FLOOR PLAN - AREA 200 A-131H FIRST FLOOR PLAN - AREA 300 A-141H FIRST FLOOR PLAN - AREA 400 A-151H FLOOR PLANS - AREA 500 A-401H ENLARGED VIEWS A-501H DETAILS A-611H DOOR SCHEDULE AND TYPES, RELITE TYPES, WALL ASSEMBLIES NUMBER SHEET DRAWING DESCRIPTION ARCHITECTURAL VICINITY MAP SHEET INDEX PROJECT TEAM ABBREVIATIONS ARCHITECTURAL SYMBOLS PROJECT INFORMATION AFF ABOVE FINISHED FLOOR CG CORNER GUARD DS DOWNSPOUT EQ EQUAL FV FIELD VERIFY GA GAUGE GWB GYPSUM BOARD MAX MAXIMUM MDF MEDIUM DENSITY FIBERBOARD MIN MINIMUM NIC NOT IN CONTRACT OC ON CENTER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OPP OPPOSITE PPT PRESSURE PRESERVATIVE TREATED SIM SIMILAR TB TACKBOARD TYP TYPICAL UNO UNLESS NOTED OTHERWISE WB WHITEBOARD SITE ADDRESS 1315 WEST YELM AVE, YELM, WA 98597 PARCEL NO. 21724210500 JURISDICTION CITY OF YELM SCOPE OF WORK SAFETY AND SECURITY UPGRADES TO THE EXISTING SCHOOL, INCLUDING: NEW SECURITY VESTIBULE, ACCESS CONTROL SYSTEM ON DOORS, CCTV SYSTEM, MODIFICATIONS TO EXISTING LIGHTING AND FIRE SPRINKLER AS REQUIRED TO ACCOMMODATE NEW VESTIBULE. YELM HIGH SCHOOL 1315 WEST YELM AVE YELM, WA 98597 ELECTRICAL TELECOM E-0.10 SITE PLAN - LEGEND, LIGHT FIXTURE SCHEDULE E-1.10 SITE PLAN - SECURITY LIGHTING E-1.11 SITE PLAN - SECURITY LIGHTING E-1.12 SITE PLAN - SECURITY LIGHTING E-1.13 SITE PLAN - SECURITY LIGHTING T-001H SECURITY LEGEND T-111H FIRST FLOOR PLAN - AREA 1 - SECURITY T-112H FIRST FLOOR PLAN - AREA 2 - SECURITY T-113H FIRST FLOOR PLAN - AREA 3 - SECURITY T-121H SECOND FLOOR PLAN - AREA 4 - SECURITY T-122H SECOND FLOOR PLAN - AREA 5 - SECURITY T-123H SECOND FLOOR PLAN - AREA 6 - SECURITY T-131H FIRST FLOOR PLAN - AREA 1 - SECURITY T-132H FIRST FLOOR PLAN - AREA 2 - SECURITY T-133H FIRST FLOOR PLAN - AREA 3 - SECURITY T-141H FIRST FLOOR PLAN - OVERALL - SECURITY T-151H FIRST FLOOR PLAN - AREA 1 - SECURITY T-152H FIRST FLOOR PLAN - AREA 2 - SECURITY YELM COMMUNITY SCHOOLS OWNER 107 1ST STREET N YELM, WA 98597 BCRA, INC ARCHITECT 2106 PACIFIC AVENUE, SUITE 300 TACOMA, WA 98402 CONTACT: HEATHER HOCKLANDER PHONE: 253.627.4367 PCS STRUCTURAL SOLUTIONS STRUCTURAL 1250 PACIFIC AVENUE, SUITE 701 TACOMA, WA 98402 CONTACT: WES NEELEY PHONE: 253.383.2797 YELM COMMUNITY SCHOOLS OWNERS REP PO BOX 476 YELM, WA 98597 CONTACT: KASEY WYATT PHONE: 360.458.1900 BCE ENGINEERS ELECTRICAL 6021 12th ST. EAST, SUITE 200 FIFE, WA 98424 CONTACT: CARRIE TAYLOR PHONE: 253.922.0446 ADAMS CONSULTING DOOR HARDWARE 2337 N 57TH ST SEATTLE, WA 98103 CONTACT: GORDON ADAMS PHONE: 206.528.0244 PERMIT - 1.23.2020 SAFETY & SECURITY IMPROVEMENTS 1 CODE INFORMATION OCCUPANCY GROUPS: PRIMARY: EDUCATIONAL (E) CONSTRUCTION TYPE: STEEL FRAMING, FULLY SPRINKLERED EGRESS: NO CHANGES TO EXISTING EXITING ROUTES OR COMPONENTS BUILDING VERTICAL FENESTRATION: METAL FRAMING, FIXED: U-FACTOR: 0.38 METAL FRAMING, ENTRACE DOORS: U-FACTOR: 0.60 LIGHTING: NO MORE THAN 50 PERCENT OF THE LUMINAIRES ARE BEING REPLACED. NEW LUMINAIRES ARE REDUCED WATTAGE LED TYPE IN ACCORDANCE WITH C503.6. ENERGY E X IS T IN G E X IT IN G M A IN T A IN E D EXISTING EXITING MAINTAINED NEW DOOR NEW WALL AND DOOR NEW WALL MECHANICAL M-001 FIRST FLOOR MECHANICAL PLAN FIRE SPRINKLER, FIRESTOPPING DEFERRED SUBMITTALS EXISTING KNOX BOX EXISTING EXITING MAINTAINED S T O P ST O P ST O PSTOPS T O P S T O P STOP RFI 632-044 N 01°13'58" E519.63'N 88°30'01" W1719.08'400.01'S 88°31'01" E837.28'S 50°11'24" E599.20'cccccccccccccccccccccccccccccccccccccccccPPH.C.H.C.H.C.H.C.H.C.H.C.K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4330KINGSTONC_TOILETSVITREOUS CHINA K-3312-4LYRICSIN K S S T A I N L E S S S T E E L K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KING STO NC _TO ILETSVITREO US C HINAK-4330KING STO NC _TO ILETSVITREO US C HINA J601 300 SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:08:10 PMA-011H 1.23.2020 19024.03 SITE PLAN PERMITYELM HIGH SCHOOL1315 W YELM AVEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1Reviewer 1" = 50'-0"1 SITE PLAN - FOR REFERENCE ONLY 0 25 50 100 1" = 50'-0" SCALE: PLAN NORTH H.C.H.C.H.C.H.C.H.C.H.C.K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-3312-4LYRICSINKSSTAINLESS STEEL K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KING STO NC _TO ILETSVITREO US C HINAK-4330KING STO NC _TO ILETSVITREO US C HINA J1. ALL DOORS ARE EXISTING TO REMAIN U.N.O. PROTECT FROM DAMAGE DURING SCOPE OF WORK. NEW DOOR NOTE:NOT ALL LEGEND ITEMS MAY BE PRESENT ON THIS SHEET NEW RELITE / WINDOW NEW WALL NEW WALL EXISTING RELITE / WINDOW EXISTING DOOR EXISTING WALL EXISTING WALL EXISTING DOOR RECIEVING UPDATES EXISTING WALL 101.3101.2101.1125.1142.1 142.2 143152.2101.8101.7190177.2186.2187.3197.6 197.4 101.5 101.6 101.4 A-401H 1 136.2 A -401H 5 SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:08:21 PMA-111H 1.23.2020 19024.03 FIRST FLOOR PLAN - AREA 100 PERMITYELM HIGH SCHOOL1315 W YELM AVEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1RTV RTV FLOOR PLAN GENERAL NOTES FLOOR PLAN LEGEND 0 8 16 32 1/16" = 1'-0" SCALE: PLAN NORTH 1/16" = 1'-0"1 FIRST FLOOR PLAN - AREA 100 K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA 205 1. ALL DOORS ARE EXISTING TO REMAIN U.N.O. PROTECT FROM DAMAGE DURING SCOPE OF WORK. NEW DOOR NOTE:NOT ALL LEGEND ITEMS MAY BE PRESENT ON THIS SHEET NEW RELITE / WINDOW NEW WALL NEW WALL EXISTING RELITE / WINDOW EXISTING DOOR EXISTING WALL EXISTING WALL EXISTING DOOR RECIEVING UPDATES EXISTING WALL SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:08:22 PMA-121H 1.23.2020 19024.03 SECOND FLOOR PLAN - AREA 200 PERMITYELM HIGH SCHOOL1315 W YELM AVEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1RTV RTV 1/16" = 1'-0"1 SECOND FLOOR PLAN - AREA 200 FLOOR PLAN GENERAL NOTES FLOOR PLAN LEGEND 0 8 16 32 1/16" = 1'-0" SCALE: PLAN NORTH 307.2 314.2 301.2 317.1331.1332.2337.2334 336 337.1333.1333.2330.1328.1317.2313.2 316.2315.21. ALL DOORS ARE EXISTING TO REMAIN U.N.O. PROTECT FROM DAMAGE DURING SCOPE OF WORK. NEW DOOR NOTE:NOT ALL LEGEND ITEMS MAY BE PRESENT ON THIS SHEET NEW RELITE / WINDOW NEW WALL NEW WALL EXISTING RELITE / WINDOW EXISTING DOOR EXISTING WALL EXISTING WALL EXISTING DOOR RECIEVING UPDATES EXISTING WALL SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:08:29 PMA-131H 1.23.2020 19024.03 FIRST FLOOR PLAN - AREA 300 PERMITYELM HIGH SCHOOL1315 W YELM AVEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1RTV RTV 1/16" = 1'-0"1 FIRST FLOOR PLAN - AREA 300 FLOOR PLAN GENERAL NOTES FLOOR PLAN LEGEND 0 8 16 32 1/16" = 1'-0" SCALE: PLAN NORTH 400.1412.1 400.2403.2404.2407.2410.2411.2411.1412.2 4061. ALL DOORS ARE EXISTING TO REMAIN U.N.O. PROTECT FROM DAMAGE DURING SCOPE OF WORK. NEW DOOR NOTE:NOT ALL LEGEND ITEMS MAY BE PRESENT ON THIS SHEET NEW RELITE / WINDOW NEW WALL NEW WALL EXISTING RELITE / WINDOW EXISTING DOOR EXISTING WALL EXISTING WALL EXISTING DOOR RECIEVING UPDATES EXISTING WALL SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:08:37 PMA-141H 1.23.2020 19024.03 FIRST FLOOR PLAN - AREA 400 PERMITYELM HIGH SCHOOL1315 W YELM AVEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1RTV RTV 1/16" = 1'-0"1 FIRST FLOOR PLAN - AREA 400 FLOOR PLAN GENERAL NOTES FLOOR PLAN LEGEND 0 8 16 32 1/16" = 1'-0" SCALE: PLAN NORTH STOP 533.3 532.6 532.7 525.2500.2500.3501.3501.2 506.2525.1 529.1 529.2 529.3 532.5 547.2 534533.5533.41. ALL DOORS ARE EXISTING TO REMAIN U.N.O. PROTECT FROM DAMAGE DURING SCOPE OF WORK. NEW DOOR NOTE:NOT ALL LEGEND ITEMS MAY BE PRESENT ON THIS SHEET NEW RELITE / WINDOW NEW WALL NEW WALL EXISTING RELITE / WINDOW EXISTING DOOR EXISTING WALL EXISTING WALL EXISTING DOOR RECIEVING UPDATES EXISTING WALL SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:08:45 PMA-151H 1.23.2020 19024.03 FLOOR PLANS - AREA 500 PERMITYELM HIGH SCHOOL1315 W YELM AVEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1RTV RTV 1/16" = 1'-0"1 FIRST FLOOR PLAN - AREA 500 1/16" = 1'-0"2 SECOND FLOOR PLAN - AREA 500 FLOOR PLAN GENERAL NOTES FLOOR PLAN LEGEND 0 8 16 32 1/16" = 1'-0" SCALE: PLAN NORTH 0 8 16 32 1/16" = 1'-0" SCALE: PLAN NORTH 101.2 101.1 125.1 142.1 RELOCATED BIKE RACK A -401H3A-401H 4 136.2 6W1 A LIG N 6W1 136.1 6 "6 "ALI GNR1 A -401H 5 A -401H 5SIM NEW JAMB TO MATCH EXISTING SILL 1. ALL DOORS ARE EXISTING TO REMAIN U.N.O. PROTECT FROM DAMAGE DURING SCOPE OF WORK. NEW DOOR NOTE:NOT ALL LEGEND ITEMS MAY BE PRESENT ON THIS SHEET NEW RELITE / WINDOW NEW WALL NEW WALL EXISTING RELITE / WINDOW EXISTING DOOR EXISTING WALL EXISTING WALL EXISTING DOOR RECIEVING UPDATES EXISTING WALL 000.0000.0RELOCATE LIGHT IN EXISTING ACT TOP OF WALL STOPS AT ACT, FRAME TOP OF WALL WITH CONTINUOUS 600T200-54 BETWEEN PERPENDICULAR WALLS ALIGN MULLION w/ EXISTING MULLION LOCATION CUT EXISTING SILL AS REQUIRED FOR INSTALL OF NEW DOOR; PATCH INTERIOR FINISHES; PROVIDE ALUMINUM THRESHOLD(S) SPANNING BETWEEN FINISHES REMOVE/REINSTALL EXISTING STOREFRONT AS REQUIRED TO MODIFY FOR NEW DOOR INSTALL "NOT AN ENTRY" SIGNAGE TO EXISTING DOOR HOLLOW METAL FRAME AND RELITE GWB, PAINT 1 A-501H 2 A-501H EXISTING ACOUSTIC CEILING TILE (2'x2') NEW DOOR AS SCHEDULED / OPENING, PER PLAN EXISTING WALL TO REMAIN EXISTING DOOR/OPENING TO REMAIN EXISTING RELITE / WINDOW TO REMAIN NEW RELITE / WINDOW / STOREFRONT AS SCHEDULED NEW WALL PER PLAN R1 RUBBER BASE CHAIR RAIL WALL NEW WALL EXISTING DEMOLISH FINISHES ON EXISTING WALL, REPLACE WITH SIMILAR 1 A-501H NEW RELITE, 600S137-43 JAMB EACH SIDE 600S137-43, SCREW TO ADJACENT WALL TOP AND BOTTOM TRACK WITH (2) #12600S137-43, SCREW TO WALL WITH (2) #8 AT 12" O.C. SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:08:53 PMA-401H 1.23.2020 19024.03 ENLARGED VIEWS PERMITYELM HIGH SCHOOL1315 W YELM AVEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1Author 1/4" = 1'-0"1 FIRST FLOOR PLAN - VESTIBULE FLOOR PLAN GENERAL NOTES FLOOR PLAN LEGEND 0 2 4 8 1/4" = 1'-0" SCALE: PLAN NORTH 1/4" = 1'-0"2 REFLECTED CEILING PLAN - VESTIBULE REFLECTED CEILING PLAN LEGEND 1/4" = 1'-0"3 EXTERIOR ELEVATION 1/4" = 1'-0"4 INTERIOR ELEVATION 1/4" = 1'-0"5 INTERIOR ELEVATION 600T150-43, TYP. 600S137-33 AT 16" O.C. (2)600S162-43 #8 AT 12" O.C., TYP. 600S137-43 #8 AT 12" O.C., TYP. 600T125-43 EXISTING WALL SCREW TO ADJACENT EXISTING WALL TOP AND BOTTOM TRACK WITH (2) #12 WALL NEW CONDUIT UL APPROVED AND TESTED SEALANT TO COMPLETELY FILL ANNULAR SPACE, PAINT TO MATCH ADJACENT AT EXPOSED TO VIEW CONDITIONS INTERIOR CONDITIONS: SEAL ANY PENETRATIONS THROUGH WALLS WITH FIRESTOPPING TO MAINTAIN EXISTING FIRE AND ACOUSTIC RATING OF WALL EXTERIOR CONDITIONS: SEALANT AS SPECIFIED IN SECTION 07 9000 SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:08:53 PMA-501H 1.23.2020 19024.03 DETAILS PERMITYELM HIGH SCHOOL1315 W YELM AVEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 13" = 1'-0"1 TOP OF WALL 6" = 1'-0"2 WALL JAMB CONNECTION TO EXISTING 3" = 1'-0"3 TYPICAL CONDUIT PENETRATION GL-1 1" INSULATED TEMPERED GLASS GL-2 1/4" TEMPERED GLASS 1. FIELD VERIFY ALL DOOR/FRAME OPENING SIZES. FINISH FLOOR 6"6"36"6"24"12"PER SCH PER SCHA ASSEMBLY TYPE AND DESCRIPTION ASSEMBLY COMPONENTS - PLAN VIEW RATED ASSEMBLY REQUIREMENTS REFER TO G-201 FOR LOCATIONS OF WALLS REQUIRING FIRE-RATED CONSTRUCTION INTERIOR LIGHT GAUGE WALL ASSEMBLY 6L1 SCALE: 1 1/2" = 1'-0" 5/8" TYPE 'X' GYPSUM BOARD 6" LIGHT GAUGE FRAMING @ 16" OC, WITH ACOUSTIC BATT INSULATION 5/8" TYPE 'X' GYPSUM BOARD INTERIOR EXTERIOR 1 FINISH FLOOR SCHED. PER EXISTINGMATCH2"FINISH FLOOR FRAME: HOLLOW METAL FINISH: PAINT GLAZING: GL-2 SHADING: NONE R1 3'-0"MATCH EXISTING FINISH FLOOR FRAME: ALUMINUM FINISH: CLEAR ANNODIZED GLAZING: GL-1 PROJECTION: NONE SHADING: NONE SF-1 EXISTINGMATCHSCHED. PER EXISTINGMATCHEXISTING MULLION SHEETPROJECTBCRA NO. DATE REVISIONS SHEET TITLE © COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVED SEAL T 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840224x36DRAWN BY: REVIEWED BY: IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY1/28/2020 1:08:54 PMA-611H 1.23.2020 19024.03 DOOR SCHEDULE AND TYPES, RELITE TYPES, WALL ASSEMBLIES PERMITYELM HIGH SCHOOL1315 W YELM AVEYELM, WA 98597SAFETY & SECURITY IMPROVEMENTS 1DOOR SCHEDULE - YELM HS DOOR NUMBER DOOR FRAME DETAIL CALLOUT FIRE RATING LABEL HARDWARE GROUP REMARKS DOOR NUMBER WIDTH HEIGHT DEPTH TYPE MAT'L FINISH GLAZING TYPE MAT'L FINISH HEAD JAMB SILL101.1 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 27 B 101.1 101.2 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 101.2 101.3 7' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 28 B 101.3 101.4 5' - 10" 7' - 0" 1 3/4" EX HM EX EX HM EX B 101.4 101.5 5' - 10" 7' - 0" 1 3/4" EX HM EX EX HM EX 29 B 101.5 101.6 5' - 10" 7' - 0" 1 3/4" EX HM EX EX HM EX B 101.6 101.7 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 27 B 101.7 101.8 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 101.8 125.1 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 125.1 136.1 3' - 0" 7' - 2" 1 3/4" A AL FF GL-1 SF-1 AL FF 25 136.1 136.2 3' - 0" 7' - 0" 1 3/4" A HM PT GL-2 1 HM PT 26 136.2 142.1 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 142.1 142.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 142.2 143 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 143 152.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 152.2 177.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 177.2 186.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 186.2 187.3 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 187.3 190 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 190 197.4 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 197.4 197.6 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 197.6 205 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 28 B 205 300 9' - 4" 7' - 0" 1 3/4" EX HM EX EX HM EX 300 301.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 301.2 307.2 2' - 8" 7' - 0" 1 3/4" EX HM EX EX HM EX 307.2 313.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 313.2 314.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 314.2 315.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 315.2 316.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 316.2 317.1 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 30 B 317.1 317.2 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 30 B 317.2 328.1 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 328.1 330.1 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 330.1 331.1 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 331.1 332.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 332.2 333.1 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 333.1 333.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 333.2 334 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 334 336 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 336 337.1 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 337.1 337.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 337.2 400.1 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 400.1 400.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 400.2 403.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 403.2 404.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 404.2 406 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 406 407.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 407.2 410.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 410.2 411.1 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 411.1 411.2 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 411.2 412.1 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 31 B 412.1 412.2 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 412.2 500.2 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 500.2 500.3 3' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 500.3 501.2 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 501.2 501.3 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 501.3 506.2 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 506.2 525.1 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 32 B 525.1 525.2 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 33 B 525.2 529.1 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 33 B 529.1 529.2 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 529.2 529.3 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 529.3 532.5 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 532.5 532.6 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 532.6 532.7 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 532.7 533.3 4' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 533.3 533.4 4' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 533.4 533.5 4' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 533.5 534 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 534 547.2 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX B 547.2 601 6' - 0" 7' - 0" 1 3/4" EX HM EX EX HM EX 601 DOOR SCHEDULE GENERAL NOTES DOOR SCHEDULE REMARKS DOOR SCHEDULE ABBREVIATIONS AL ALUMINUM EX EXISTING FF FACTORY FINISH GL-# GLAZING TYPE HM HOLLOW METAL PT PAINT ST STAIN WD WOOD A. PROVIDE MAGNETIC HOLD OPEN B. PAIR OF DOORS GLAZING TYPES 1/4" = 1'-0"1 DOOR TYPES 1/4" = 1'-0"2 DOOR FRAME TYPES 1/4" = 1'-0"4 RELITE TYPES 1/4" = 1'-0"3 STOREFRONT TYPES 01 -2 3 -2 0 20 SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADES E-0.10SITE PLAN -LEGEND,LIGHT FIXTURE SCHEDELECTRICAL LEGENDEQUIPMENT AND WIRINGMISCELLANEOUS SYMBOLDESCRIPTIONLIGHTINGPOLE LIGHT FIXTURE (ARROW INDICATES DIRECTION OF AIMING FOR OPTICS)GROUNDING CONDUCTORGROUNDING SYSTEM PER CODEDEDICATED CONDUIT HOMERUN TO PANEL & CIRCUIT NUMBERS AS INDICATED ON PLANSJUNCTION BOX - SIZE PER CODE (F INDICATES FIRE ALARM SYSTEM)MARKS INDICATE NUMBER OF #12 AWG UNLESS NOTED OTHERWISERACEWAY CONCEALED IN WALL OR CEILINGRACEWAY CONCEALED UNDERGROUND OR UNDER FLOOR SLABHHHANDHOLEJCONDUIT STUB OUT (PROVIDE CONCRETE MARKER ON EXTERIOR)ALL DEVICES WITH LIGHT LINE WEIGHT INDICATES EXISTING TO BE RETAINEDCONSTRUCTION NOTESW INDICATES WEATHERPROOF FOR ALL DEVICES, PROVIDE LOCKING COVER ON RECEPTACLES.SSWLOW VOLTAGE LIGHTING CONTROL PANELPCLCWALL MOUNT LED LIGHT FIXTURESURFACE MOUNT LED LIGHT FIXTUREWALL MOUNT LED LIGHT FIXTUREEXISTING PANELBOARD TO BE RETAINEDDEMOLITION NOTESALL DEVICES WITH DASH LINE INDICATES EXISTING TO BE REMOVED11PHOTOCELL FOR LIGHTING CONTROL PANEL(PROVIDE WITH TIME-DELAY CIRCUITS TO PREVENT CYCLING OF LIGHT LEVEL CHANGES OF LESS THANTHREE MINUTES PER WASHINGTON STATE ENERGY CODE C405.2.2.3-2)SWITCHES1.SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR SHEET.2.THE CONTRACTOR/INSTALLING VENDOR IS RESPONSIBLE TO VERIFY ALL CMU/CONCRETEWALLS, BRICK WALLS, CABLE ROUTING AND ALL WORK REQUIRED TO FACILITATE A COMPLETEAND FULLY FUNCTIONAL SYSTEM.3.THE CONTRACTOR SHALL REFER TO STRUCTURAL DRAWINGS FOR BRACE FRAMED OR SHEARWALLS. CONTRACTOR SHALL MOUNT DEVICES AND ROUTE CONDUIT SO AS NOT TO INTERFEREWITH THE STRUCTURAL INTEGRITY OF THE WALL.4.CONDUIT SHALL NOT BE SURFACE MOUNTED IN ANY FINISHED AREAS WITHOUT SPECIALPERMISSION FROM THE ARCHITECT. CONTRACTOR SHALL TAKE SPECIAL CARE ANDCOORDINATE WITH OTHER DISCIPLINES TO INSURE CONDUIT IS HIDDEN.5.NO CONDUITS ARE ALLOWED TO BE ROUTED ON TOP OF ROOF.6.SEE ALL DETAIL SHEETS AND RISER DIAGRAMS FOR ADDITIONAL WORK. ALL DETAILS ANDRISERS ARE APPLICABLE TO THIS PROJECT WHETHER REFERENCED OR NOT.7.GROUNDING SHALL CONFORM TO NEC 250.8.CIRCUITING SHALL BE PROVIDED AS REQUIRED TO MEET THE NEC. ALL SINGLE POLE CIRCUITSSHALL BE PROVIDED WITH DEDICATED NEUTRALS.9.SEE ARCHITECTURAL DRAWINGS AND FIELD VERIFY FOR FIRE WALLS REFER TO FINALARCHITECTURAL DRAWINGS FOR RATED WALLS, AND PROVIDE FIRE RATED MECHANICALPENETRATIONS (STI EZ-PATH OR EQUAL) FOR ALL CABLES TRANSITIONING THROUGH RATEDWALLS. EC SHALL FIRE SEAL AROUND ALL CONDUITS PENETRATING THROUGH FLOORS, ROOF,AND FIRE RATED WALLS.10.COMMISSIONING SHALL BE PROVIDED PER WASHINGTON STATE ENERGY CODE. C103.6, C405,AND C408 AS REQUIRED. COORDINATE ALL WORK WITH COMMISSIONING CONTRACTOR.GENERAL NOTES (APPLY TO ALL DRAWINGS)1.IT IS THE CONTRACTOR'S RESPONSIBILITY TO INCLUDE IN HIS BID ALL COSTSASSOCIATED WITH NECESSARY DEMOLITION TO ALLOW NEW CONSTRUCTION SHOWN INCONTRACT DOCUMENTS. UNLESS OTHERWISE NOTED, THE CONTRACTOR SHALLREMOVE ALL EXISTING RECEPTACLES, LIGHTING FIXTURES, DEVICES, ABANDONEDRACEWAYS, CONDUCTORS, TOGETHER WITH ANY AUXILIARY ITEMS TO ALLOW NEWCONSTRUCTION AND FINISH TO OCCUR AS COMPLEMENTED BY THE CONTRACTDOCUMENTS. DASHED LINES INDICATE EXISTING DEVICES AND EQUIPMENT TO BEREMOVED.2.THESE PLANS DELINEATE THE BASIC SCOPE OF WORK FOR THE REMOVAL OF EXISTINGMATERIAL. THE DEMOLITION DRAWINGS AND NOTES ARE PROVIDED WITH THE INTENT TOGENERALLY DESCRIBE AREAS AND LIMITS OF WORK. THE CONTRACTOR SHALL BEFAMILIAR WITH THE SITE AND CONDITIONS THERE ON; AND SHALL NOT RELY SOLELY ONREVIEW OF THE BIDDING DOCUMENTS IN DETERMINING THE EXTENT OF DEMOLITIONWORK REQUIRED. COORDINATION OF THESE DRAWINGS WITH REQUIREMENTS FORCONTRACT WORK IS THE RESPONSIBILITY OF THE CONTRACTOR. DISCREPANCIESBETWEEN OR WITHIN THE CONTRACT DOCUMENTS SHALL BE REPORTED TO THEENGINEER IMMEDIATELY. THE CONTRACTOR SHALL PROVIDE CLARITY SKETCHES,DIAGRAMS, AND FIELD DIMENSIONS OF EXISTING CONDITIONS AT THE REQUEST OF THEENGINEER IF/WHEN CONFLICTS ARE IDENTIFIED.3.REMOVE ALL WIRES, CABLES, SURFACE MOUNT RACEWAYS AND ALL APPURTENANCESWHICH SERVE DEVICES BEING REMOVED. CUT CONDUIT FLUSH TO CEILING OR WALLWHEN CONCEALED, AND SEAL OFF WITH SPRAY FOAM. ABANDON FLUSH BOXES ANDNON-ACCESSIBLE CONDUIT, PROVIDE COVER PLATES FOR ALL BOXES TO REMAIN. CUTCONDUIT FLUSH TO FLOOR AND SEAL WITH GROUT.4.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR FOR ALLCUTTING, PATCHING AND FINISH WORK.5.CONTRACTOR SHALL REMOVE AND DELIVER TO OWNER ALL DEVICES THAT AREIDENTIFIED BY OWNER TO BE RETAINED. CONTRACTOR SHALL COORDINATE WITHOWNER TO ASSURE THAT ALL ITEMS TO BE RETAINED ARE IDENTIFIED PRIOR TO THESTART OF DEMOLITION. ALL ITEMS NOT SO IDENTIFIED SHALL BECOME PROPERTY OFTHE CONTRACTOR AND SHALL BE DISPOSED OF OFF SITE.6.UNLESS NOTED OTHERWISE DISCONNECT AND REMOVE ALL DEVICES INDICATED.MAINTAIN CONTINUITY OF ALL REMAINING DEVICES & EQUIPMENT. PROVIDE JUNCTIONBOXES, CONDUIT AND WIRE TO EXTEND EXISTING CIRCUITS AS REQUIRED.GENERAL DEMOLITION NOTES (APPLY TO ALL DRAWINGS)1/23 /20 SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADES E-1.10SITE PLAN - SECURITYLIGHTINGSCALE:N1SITE PLAN - SECURITY LIGHTING1"=20'-0"20'10'020'40'SCALE: 1"=20'-0"EXISTINGBUILDINGMOUNTEDLIGHTS(TYPICAL)WL2WL2WL2111WL1WL1@7'-0"@7'-0"WL21WL21WL21WL2@10'-0"EXISTINGPARKING LOTLIGHTING(TYPICAL)EXISTINGPARKING LOTLIGHTING(TYPICAL)EXISTINGLIGHT ABOVEDOOR IN ALCOVEEXISTINGLIGHT ABOVEDOOR IN ALCOVEWL2@10'-0"WL2@10'-0"@7'-0"WL1WL2WL2WL2WL2@10'-0"@10'-0"E-1.10E-1.11E-1.10E-1.11E-1.10 E-1.12 CONSTRUCTION NOTESREPLACE EXISTING LIGHT WITH NEW.1E1.10GENERAL NOTES1.SEE GENERAL NOTES ON SHEET E0.10.DEMOLITION NOTES1.SEE GENERAL DEMOLITION NOTES ON SHEET E0.10.1/23 /20 SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADES E-1.11SITE PLAN - SECURITYLIGHTINGSCALE:N1SITE PLAN - SECURITY LIGHTING1"=20'-0"20'10'020'40'SCALE: 1"=20'-0"STOPSTOPEXISTINGSURFACEDOWNLIGHTEXISTING DOWNLIGHTSUNDERNEATH OVERHANG(TYPICAL OF 7)WL3WL3WL3WL311E-1.10E-1.11E-1.10E-1.11E-1.11 E-1.12 E-1.11 E-1.12 WL3+23' AFG+23' AFG+23' AFGWL31WL41E1.11GENERAL NOTES1.SEE GENERAL NOTES ON SHEET E0.10.DEMOLITION NOTES1.SEE GENERAL DEMOLITION NOTES ON SHEET E0.10.CONSTRUCTION NOTESELECTRICAL CONTRACTOR TO FIELD VERIFY EXACT EXISTING LIGHT FIXTURELOCATION. EXISTING LIGHT FIXTURE TO BE REMOVED. RETAIN EXISTING LIGHTINGCIRCUIT FOR NEW LIGHT FIXTURE. PROVIDE NEW SURFACE MOUNTED LIGHTFIXTURE AND CONNECT TO EXISTING LIGHTING CIRCUIT.11/23 /20 SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADES E-1.12SITE PLAN - SECURITYLIGHTINGSCALE:N1SITE PLAN - SECURITY LIGHTING1"=20'-0"20'10'020'40'SCALE: 1"=20'-0"STOPWL6WL5WL5WL5E-1.10E-1.12E-1.11E-1.12E-1.11E-1.12 E-1.12 E-1.13 E-1.12 E-1.13SL11SL11SL11SL11SL11+12' AFG+12' AFG+12' AFG+20' AFGWL6+20' AFGWL7+12' AFGWL7+12' AFGE1.12GENERAL NOTES1.SEE GENERAL NOTES ON SHEET E0.10.DEMOLITION NOTES1.SEE GENERAL DEMOLITION NOTES ON SHEET E0.10.CONSTRUCTION NOTESMOUNT NEW LIGHT FIXTURE UNDERSIDE OF CANOPY.11/23 /20 SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADES E-1.13SITE PLAN - SECURITYLIGHTINGSCALE:N1SITE PLAN - SECURITY LIGHTING1"=20'-0"20'10'020'40'SCALE: 1"=20'-0"SL2SL211SL21E-1.12E-1.13 E-1.12E-1.13SL21SL21SL21SL21 SL21SL21E1.13GENERAL NOTES1.SEE GENERAL NOTES ON SHEET E0.10.DEMOLITION NOTES1.SEE GENERAL DEMOLITION NOTES ON SHEET E0.10.CONSTRUCTION NOTESELECTRICAL CONTRACTOR TO FIELD VERIFY EXACT EXISTING LIGHT FIXTURELOCATION. EXISTING LIGHT FIXTURE TO BE REMOVED. RETAIN EXISTING LIGHTINGCIRCUIT FOR NEW LIGHT FIXTURE. PROVIDE NEW SURFACE MOUNTED LIGHTFIXTURE AND CONNECT TO EXISTING LIGHTING CIRCUIT.11/23 /20 SYMBOLDESCRIPTIONSECURITY LEGENDCINTERIOR CCTV CAMERA - 'W' INDICATES WALL MOUNT, 'C' INDICATES CEILING MOUNT, 'CN' INDICATES CORNER MOUNT. SEETHE CCTV RISER DIAGRAM AND MOUNTING DETAILS FOR ADDITIONAL REQUIREMENTS. MAINTAIN THETELECOMMUNICATIONS OUTLET REQUIREMENTS. PROVIDE (1) DATA PORT AND (1) CAT6 CABLE WITH A 10-FOOT SERVICELOOP FOR EACH CAMERA SHOWN ON THE DRAWINGS. MAINTAIN THE TELECOMMUNICATIONS OUTLET REQUIREMENTS.PROXIMITY CARD READER - WALL MOUNT. (M INDICATES MULLION MOUNT). SEE ACCESS CONTROL RISER DIAGRAM AND RELATED DETAILS FOR MOREINFORMATION. MOUNT AT +48" UNLESS NOTED OTHERWISE.DOOR POSITION SWITCH (A DPDT SHALL BE PROVIDED AT EACH LOCATION SHOWN). CONNECT EXISTING INTRUSION CABLINGTO THE NEW DPDT SWITCH. PROVIDE NEW CABLING FOR ACCESS CONTROL MONITORING.ACCESS CONTROL READER I/O INTERFACE - WALL MOUNT ABOVE ACCESSIBLE CEILING SPACE - PROVIDE CABLING TO THENEAREST ACCESS CONTROL PANEL. SEE ACCESS CONTROL RISER DIAGRAM AND RELATED DETAILS FOR MOREINFORMATION.REQUEST TO EXIT - REX SHALL BE INTEGRAL TO THE DOOR HARDWARE AND PROVIDED BY DIVISION 8. PROVIDE NECESSARYCABLING FROM ACP/ ACRI AT EACH LOCATION.ACCESS CONTROL SYSTEM POWER SUPPLYELECTRIFIED EXIT DEVICE - SHOWN FOR REFERENCE ONLY. COORDINATE WITH DOOR HARDWARE FOR EXACT DEVICE AT EACHLOCATION.CACCESS CONTROL PANEL - MOUNTED ABOVE ACCESSIBLE CEILING SPACE. PROVIDE (1) DATA PORT AND (1) CAT6 CABLEWITH A 10-FOOT SERVICE LOOP AT EACH LOCATION. SEE ACCESS CONTROL RISER DIAGRAM AND RELATED DETAILS FORMORE INFORMATION.1.EXISTING ANALOG CCTV SYSTEM IN BUILDING 1 IS TO REMAIN FULLY OPERATIONAL UNTIL NEW IPCCTV SYSTEM IN BUILDING 1 IS FULLY OPERATIONAL. EXISTING ANALOG CCTV SYSTEM TOINCLUDE OLD CCTV CABLING SHALL BE DEMOLISHED AFTER THE VA HAS APPROVED THE NEW IPCCTV SYSTEM. TURN OVER ALL OLD CCTV DEVICES TO THE OWNER. PROVIDE NEW CEILING TILESAS REQUIRED. PATCH ANY WALL AND CEILING SURFACES IN HARD LID AREAS WHERE ANY OLDCAMERAS WHERE INSTALLED. PAINT TO MATCH ADJACENT SURFACE.2.SEE EACH SHEET FOR ADDITIONAL GENERAL NOTES THAT ARE SPECIFIC TO AN AREA OR SHEET.3.REVIEW PLANS FOR LOCATIONS OF AREAS WITH ACCESSIBLE CEILING TILES, GWB, AND OPENCEILINGS. PROVIDE MANUFACTURER APPROVED BACK BOXES IN AREAS WITH CEILINGS THAT AREOPEN TO STRUCTURE. ALL CABLE/CONDUIT ROUTING SHALL USE THE EXISTING CORRIDORS ASTHE MAIN ROUTING PATH AS MUCH AS POSSIBLE BEFORE CROSSING INTO OTHER AREAS TO GETTO DEVICE/IDF LOCATIONS. LINE OF SIGHT ROUTING OF THE CABLE/CONDUITS WILL NOT BEACCEPTABLE.4.UTILIZE EXISTING CABLING TRAY WHEN EVER POSSIBLE IN BUILDINGS WITH CABLE TRAY. OPENCABLING IS ACCEPTABLE IN ACCESSIBLE CEILING SPACES ONLY. ANY AREA WITH OUT ACCESSIBLECEILING SPACE OR CABLE TRAY SHALL HAVE ALL CABLES RUN IN CONDUIT.5.ALL CONDUIT SHALL BE RUN PARALLEL OR PERPENDICULAR TO STRUCTURE.6.EC SHALL FIRE SEAL AROUND ALL CONDUITS PENETRATING THROUGH FLOORS, ROOF, AND FIRERATED WALLS.7.IN HARD LID CEILINGS, AND AREAS WITH CEILINGS THAT ARE OPEN TO STRUCTURE. PROVIDESURFACE-MOUNTED DEVICES AND THEIR RELATED SURFACE MOUNT BACK BOXES AND SURFACEMOUNTED CONDUIT IN AREAS WITH CEILINGS THAT ARE OPEN TO STRUCTURE. PAINT EACHBACKBOX AND CONDUIT TO MATCH THE ADJACENT SURFACE.8.ROOMS AND/OR AREAS WITH EXPOSED CEILINGS SHALL HAVE ALL CABLES ROUTED IN CONDUIT.CONDUIT SHALL BE TIGHT TO STRUCTURE, ROUTED PARALLEL AND ADJACENT TO STRUCTURE,AND SHALL BE PAINTED TO MATCH ADJACENT SURFACE. SURFACE MOUNTED CONDUITS SHALLNOT BE UTILIZED IN OCCUPIED SPACES.9.WHERE OPEN CABLING IS PERMITTED BY CODE, EACH LOW VOLTAGE SYSTEM SHALL HAVE THEIRCABLES SUSPENDED SEPARATE FROM OTHER LOW VOLTAGE SYSTEMS (I.E. FIRE ALARM CABLESIN ONE J-HOOK, INTRUSION ALARM IN ANOTHER J-HOOK, AND SO ON). ALL CABLES MUST BEROUTED IN CONDUIT IN AREAS WITH EXPOSED CEILINGS. CATEGORY RATEDTELECOMMUNICATIONS CABLING FOR DATA, VOICE, IP INTERCOM/CLOCK SPEAKER, CCTV ANDACCESS CONTROL MAY SHARE THE SAME J-HOOK AND PATHWAYS. EXISTING CABLE TRAY SHALLBE UTILIZED WHENEVER POSSIBLE. IF EXISTING J-HOOK/CABLE TRAY IS ALREADY FULL, THEN NEWJ-HOOK/CABLE TRAY SYSTEM SHALL BE PROVIDED FOR WIRING THIS PROJECT.10.ALL OUTLETS, SWITCHES AND DEVICES MOUNTED BACK TO BACK IN A WALL, MUST BE SPACED AMINIMUM OF 24" APART OR FURNISHED WITH SOUND ATTENUATING MASTIC AROUND THE BOX TOMEET ACOUSTICAL REQUIREMENTS.11.ALL TYPICAL DEVICES SHALL BE MOUNTED AT CONSISTENT LOCATIONS AND HEIGHTSTHROUGHOUT THIS PROJECT, UNLESS NOTED OTHERWISE.12.SEE THE SITE PLANS FOR ADDITIONAL WORK.13.CAMERAS SHALL BE LOCATED AS SUCH TO AVOID RESTRICTING THE CAMERAS FIELD OF VIEWFROM: EXIT SIGNS, LIGHTING, DOOR HEADERS, BUILDING FEATURES, BANNERS, OR OTHER (ART)ITEMS HANGING FROM THE CEILING. COORDINATE WITH ALL TRADES AS REQUIRED PRIOR TOROUGH-IN.14.SEE THE ACCESS CONTROL SYSTEM RISER DIAGRAM, RELATED DETAIL SHEETS, AND THEELECTRICAL LEGEND, FOR EQUIPMENT THAT IS NOT SHOWN ON THE FLOOR PLANS, BUT SHALL BEPROVIDED AND INSTALLED FOR THIS PROJECT. MOUNT ACCESS CONTROL PANEL IN ACCESSIBLECEILING SPACE AS CLOSE AS POSSIBLE TO THE DOOR THE PANEL IS CONTROLLING.15.SEE ALL DETAIL SHEETS AND RISER DIAGRAMS FOR ADDITIONAL WORK REQUIRED BY SECTIONS271500.16.ROUTE ALL TELECOMMUNICATIONS CABLING TO THE CLOSEST IDF OR MDF. COPPERTELECOMMUNICATIONS CABLING NOT TO EXCEED 295' TOTAL RUN LENGTH. ANY RUN LENGTHSEXCEEDING 295' SHALL USE 2 STRAND MULTI-MODE FIBER OPTIC CABLE WITH MEDIA CONVERTERSON BOTH ENDS AND A POWER CONDUCTOR FROM DEDICATED POWER SUPPLY SIZED TO MEETLOAD AND DISTANCE CAPACITY OF THE CCTV CAMERA AND MEDIA CONVERTER.17.ALL MEDIA CONVERTERS MOUNTED ON POLES OR EXTERIOR APPLICATIONS SHALL BE MOUNTEDIN NEMA 4 ENCLOSURES. ACTIVE ELECTRONIC COMPONENTS ARE REQUIRED TO BE MOUNTEDABOVE GRADE AND ARE NOT ALLOWED IN HANDHOLD OR SYSTEM VAULTS.18.MOUNT EXTERIOR CAMERAS AT 12' TO 15' AFF OR AS CLOSE AS POSSIBLE TO OBTAIN BEST VIEWFROM CAMERAS. MAINTAIN CONSTANT MOUNTING HEIGHT THROUGHOUT FOR EACH CAMERA. SEECAMERA MOUNTING DETAIL SHEET FOR MORE INFORMATION. COORDINATE WITH OWNER ASREQUIRED FOR EXACT CAMERA LOCATION AND ALL MOUNTING CONFLICTS.19.FOR DEVICES MOUNTED ON EXTERIOR WALLS, SURFACE MOUNT AND CORE DRILL AS REQUIREDFOR ROUTING OF CONDUIT. PROVIDE SURFACE MOUNTED METAL RACEWAY PAINTED TO MATCHADJACENT SURFACE. SEAL AROUND ALL PENETRATIONS.20.ALL WORK SHALL BE DONE IN A MANOR TO MINIMIZE THE IMPACT ON PATIENT CARE. COORDINATEWITH THE VA FOR BEST WORK TIME AND ACCESS TO SPACES. ALL WORK IN PATIENT SPACESSHALL CONFORM TO VA GUIDELINES FOR CLEAN SPACE REQUIREMENTS.21.SURFACE MOUNTED CONDUIT WITHIN VAULTED CEILINGS OF BUILDING 1 IS NOT ALLOWED.CONTRACTOR SHALL ROUTE THE CABLING TO ADJACENT ROOMS TO FACILITATE CABLEINSTALLATION.MAGNETIC DOOR HOLDERW/C/CNDUPLEX RECEPTACLEJUNCTION BOX - SIZE PER CODECONSTRUCTION NOTESW INDICATES WEATHERPROOF FOR ALL DEVICES, PROVIDE LOCKING COVER ON RECEPTACLES.WALL DEVICES WITH LIGHT LINE WEIGHT INDICATES EXISTING TO BE RETAINEDALL DEVICES WITH DASH LINE INDICATES EXISTING TO BE REMOVEDDEMOLITION NOTESELEVATION CALL OUT - A INDICATES ELEVATION DETAIL IDENTIFICATION, E4.01 INDICATES SHEETELEVATION DETAIL DRAWN ON11DATA OUTLET - (1) DATA PORT AND (1) CAT6 CABLES WITH 10' SERVICE LOOP IN CLOSEST ACCESSIBLE CEILING SPACE. NUMBERINDICATES IF DIFFERENT THAN 1#HANDHOLEUNDERGROUND CONDUITEMERGENCY LOCK DOWN CONTROL BUTTONW/C/CNEXTERIOR CCTV CAMERA - 'W' INDICATES WALL MOUNT, 'C' INDICATES CEILING MOUNT, 'CN' INDICATES CORNER MOUNT.SEE THE CCTV RISER DIAGRAM AND MOUNTING DETAILS FOR ADDITIONAL REQUIREMENTS. MAINTAIN THETELECOMMUNICATIONS OUTLET REQUIREMENTS. PROVIDE (1) DATA PORT AND (1) CAT6 CABLE WITH A 10-FOOT SERVICELOOP FOR EACH CAMERA SHOWN ON THE DRAWINGS. MAINTAIN THE TELECOMMUNICATIONS OUTLET REQUIREMENTS.ACRIACPACPSCRDREXEDELDPBDOOR RELEASE PUSH BUTTONCCTV MONITOR - MOUNT AT +60" AFF UNLESS NOTED OTHERWISE. PROVIDE AS SPECIFIED.MONSHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADES T-001HSECURITY LEGEND1/23 /20 K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINACR CRCCCCCCDDDDDDDDDDDDDDED CRED ED CRMEDDP B E LD MONELDAC P1 3ACP1A C R I ACRI11 111111114424141422131215WMCWCNCNW25CONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA, ACCESS CONTROL PANEL,AND MONITOR LOCATION.ACCESS CONTROL PANEL / INTERFACE AND POWER SUPPLY AS SPECIFIED. MOUNTABOVE ACCESSIBLE CEILING SPACE. PROVIDE 120 VOLT CIRCUIT.PROVIDE A DUPLEX RECEPTACLE AND 120 VOLT POWER FOR THE MONITOR.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN IDF 1.1.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN MDF 2.1.12345SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADES T-111HFIRST FLOOR PLAN -AREA 1 - SECURITYSCALE:N1FIRST FLOOR PLAN - AREA 1 - SECURITY1/8" = 1'T-112HT-111HT-113H1/23 /20 CRCRCCCDDDDDDDD DDDDE DED EDEDCRMACPACPEXISTING IDF 1.1A C R I 1213W12311231W114131CNCONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA AND ACCESS CONTROLPANEL LOCATION.ACCESS CONTROL PANEL / INTERFACE AND POWER SUPPLY AS SPECIFIED. MOUNTABOVE ACCESSIBLE CEILING SPACE. PROVIDE 120 VOLT CIRCUIT.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN IDF 1.1.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN MDF 2.1.1234SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADEST-112HFIRST FLOOR PLAN -AREA 2 - SECURITYSCALE:N1FIRST FLOOR PLAN - AREA 2 - SECURITY1/8" = 1'T-112HT-111HT-113H1/23 /20 H.C.H.C.H.C.H.C.H.C.H.C.K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-3312-4LYRICSINKSSTAINLESS STEEL K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA CRCCCCCDDDDDDDDDDEDACP11112W114121CNCN121CCC112121W25CONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN MDF 2.1.12SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADEST-113HFIRST FLOOR PLAN -AREA 3 - SECURITYSCALE:N1FIRST FLOOR PLAN - AREA 3 - SECURITY1/8" = 1'T-112HT-111HT-113H1/23 /20 CCEXISTING IDF 2(IN CEILING)112C113CK-4330KINGSTONC_TOILETSVITREOUS CHINAK-4330KINGSTONC_TOILETSVITREOUS CHINAK-4330KINGSTONC_TOILETSVITREOUS CHINAK-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINAK-4330KINGSTONC_TOILETSVITREOUS CHINA CONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN IDF 2.12SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADEST-121HSECOND FLOOR PLAN -AREA 4 - SECURITYSCALE:N1SECOND FLOOR PLAN - AREA 4 - SECURITY1/8" = 1'T-115HT-114HT-116H1/23 /20 CCCREDDDACP1EXISTING IDF 2(IN CEILING)113C113W123K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA K-4330KINGSTONC_TOILETSVITREOUS CHINA CONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA AND ACCESS CONTROLPANEL LOCATION.ACCESS CONTROL PANEL / INTERFACE AND POWER SUPPLY AS SPECIFIED. MOUNTABOVE ACCESSIBLE CEILING SPACE. PROVIDE 120 VOLT CIRCUIT.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN IDF 2.123SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADEST-122HSECOND FLOOR PLAN -AREA 5 - SECURITYSCALE:N1SECOND FLOOR PLAN - AREA 5 - SECURITY1/8" = 1'T-115HT-114HT-116H1/23 /20 CEXISTING MDF112CSHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADEST-123HSECOND FLOOR PLAN -AREA 6 - SECURITYSCALE:N1SECOND FLOOR PLAN - AREA 6 - SECURITY1/8" = 1'T-115HT-114HT-116H1/23 /20 CCCCDDDDDDDDDDDDDEXISTING IDF 3.1(2ND LEVEL PLATFORM)EDACP11C23113CN131CN131CN131DDCONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA AND ACCESS CONTROLPANEL LOCATION.ACCESS CONTROL PANEL / INTERFACE AND POWER SUPPLY AS SPECIFIED. MOUNTABOVE ACCESSIBLE CEILING SPACE. PROVIDE 120 VOLT CIRCUIT.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN IDF 3.1.123SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADEST-131HFIRST FLOOR PLAN -AREA 1 - SECURITYT-131HT-132HT-133HSCALE:N1FIRST FLOOR PLAN - AREA 1 - SECURITY1/8" = 1'1/23 /20 DDDDDEDACP112SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADEST-132HFIRST FLOOR PLAN -AREA 2 - SECURITYSCALE:N1FIRST FLOOR PLAN - AREA 2 - SECURITY1/8" = 1'T-131HT-132HT-133H1/23 /20 CDDDDD1121WCONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA AND ACCESS CONTROLPANEL LOCATION.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN IDF 3.1.12SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADEST-133HFIRST FLOOR PLAN -AREA 3 - SECURITYSCALE:N1FIRST FLOOR PLAN - AREA 3 - SECURITY1/8" = 1'T-131HT-132HT-133H1/23 /20 CCCDDDDDDDDDDDDCREDCACP3CONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA AND ACCESS CONTROLPANEL LOCATION.ACCESS CONTROL PANEL / INTERFACE AND POWER SUPPLY AS SPECIFIED. MOUNTABOVE ACCESSIBLE CEILING SPACE. PROVIDE 120 VOLT CIRCUIT.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN IDF 4.1.123EXISTING IDF 4.12111C31CN131CN131W131SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADEST-141HFIRST FLOOR PLAN -OVERALL - SECURITYSCALE:N1FIRST FLOOR PLAN - OVERALL - SECURITY1/8" = 1'1/23 /20 CONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA AND ACCESS CONTROLPANEL LOCATION.ACCESS CONTROL PANEL / INTERFACE AND POWER SUPPLY AS SPECIFIED. MOUNTABOVE ACCESSIBLE CEILING SPACE. PROVIDE 120 VOLT CIRCUIT.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN IDF 5.1.123XXCCCCCDDDDDDDDDDDDD D D D EDCRACPEXISTING IDF 5.1 (IN MEZZANINE)CN1311313131311112311WCCWCNWSHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADEST-151HFIRST FLOOR PLAN -AREA 1 - SECURITYSCALE:N1FIRST FLOOR PLAN - AREA 1 - SECURITY1/8" = 1'T-152HT-151H1/23 /20 CCCCCCDDDDDDDDDDDD D CREDCACP1131313131313132311111111CNCNWWCNCCCONSTRUCTION NOTESPROVIDE (1) CAT6 DATA DROP FOR EACH CCTV CAMERA AND ACCESS CONTROLPANEL LOCATION.ACCESS CONTROL PANEL / INTERFACE AND POWER SUPPLY AS SPECIFIED. MOUNTABOVE ACCESSIBLE CEILING SPACE. PROVIDE 120 VOLT CIRCUIT.ROUTE CAT6 DATA CABLE TO NEW PATCH PANEL IN IDF 3.1.123SHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402 24x36 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY11/22/2019 10:49:34 AM 01.23.202019024PERMITYELM HIGH SCHOOL 1315 YELM AVE YELM, WA 98597 SECURITY UPGRADEST-152HFIRST FLOOR PLAN -AREA 2 - SECURITYSCALE:N1FIRST FLOOR PLAN - AREA 2 - SECURITY1/8" = 1'T-152HT-151H1/23 /20