2020.0061.BP0006 REFRIGERATION PLANS - Grocery Outlet4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com BCDFGA112233445566E4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com···· BCDFGA112233445566E4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com 123456123456FG123DFGEFG4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com 4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com ··422-3/411/161/2 in. - 14 NPTFor3/4 in. - 14 NPTF,as specified (both ends)2-9/161-1/21-1/83/42-5/161-1/2Dimensions for F261 Low-Flow Switch.120° upWhen mounting the flow switch on horizontal pipe,mount the flow switch within 60 degrees of vertical.60°fromvertical60°fromverticalFlow Direction for Vertical MountingIMPORTANT: Do not use in a vertical pipeline witha downward flow.Mount the F261 flow switch in a horizontal pipeline or avertical pipeline with upward fluid flow. When mountedin a vertical pipe with an upward flow, the switch trips ata slightly higher flow than shown in Table 4 andTable 5, due to the effect of gravity on the switchmechanism.Mount the F261 flow switch in a section of pipe wherethere is a straight run of at least five pipe diametersfrom the nearest elbow, valve, or other pipe restriction.Tee or WeldedHalf-CouplingFLOWFLOWAngle AllowedNote: Do not subject the flow switches to waterhammer. Use a suitable water hammer arrester if afast-closing valve is located downstream of the switch.FLOWDimension must be at leastfive pipe diameters from the nearestelbow, valve, or other pipe restriction.A Required Piping DistanceFIG: Flw_dir 4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com OPTIONAL WIRINGTO THE TOP12 in X 10 in X 4 in40 13/16" [103.7 cm]124 in24 in24 in24 in24 in24 in30 5/8" [77.8 cm]COILPLENUMLOAD LIMIT6 15/16" [17.6 cm]31 1/2" [80.0 cm]40 1/2" [102.9 cm]42 3/4" [108.6 cm]PIPING TO THE TOP(OPTIONAL)12" [30.5 cm]WIRING TO THETOP (OPTIONAL)2" MINIMUM AIR GAPREAR REFRIGERATIONLOCATED 14 1/2" ABOVE FINISH FLOORELECTRICALDEFAULT REFRIGERATIONJUNCTION BOX1 1/2" PVC DRAINCONNECTION1 1/2" [3.8 cm] ENDNOTES:*: STUB-UP AREA** : RECOMMENDED STUP-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS:AVAILABLE SHELF SIZES: 18", 20", 22" & 24"• End add approximately 1" to case height48" [121.9 cm]72" [182.9 cm]96" [243.8 cm]144" [365.8 cm]8 3/4" [22.2 cm]42 3/4" [108.6 cm] 40 1/2" [102.9 cm] 31 1/2" [80.1 cm] 91 7/8" [233.4 cm] OVERALL CASE HEIGHT 94 1/8" [239.1 cm] SHIPPING HEIGHT 28 1/2" [72.4 cm]* 4 1/8" [10.5 cm] 88 5/8" [225.1 cm] CASE HEIGHT 71" [180.3 cm] INTERIOR HEIGHT 13 5/8" [34.6 cm] 14 3/4" [37.5 cm] 66 3/4" [169.6 cm] VISUAL DISPLAY 1 11/16" [4.3 cm] 3" [7.6 cm] 28 1/8" [71.5 cm] 35 1/8" [89.2 cm]** 82 1/2" [209.6 cm]41 1/4" [104.8 cm]37 5/8" [95.6 cm]29 3/4" [75.6 cm]19 5/8" [49.8 cm]13 5/8" [34.6 cm]5 7/8" [14.9 cm]5 1/8" [13.1 cm]27 1/2" [69.9 cm]34 3/8" [87.3 cm]**15 9/16" [39.6 cm]36 1/16" [91.6 cm]13 5/8" [34.6 cm]LOAD LIMIT LINE29 11/16" [75.4 cm]33" [83.8 cm]6 3/8" [16.2 cm]29 7/8" [75.9 cm]31 1/4" [79.3 cm]37 5/8" [95.6 cm]41 7/16" [105.3 cm]82 1/2" [209.6 cm]1 1/2" [3.8 cm] END12" [30.5 cm]REFRIGERATION(OPTIONAL)KICKPLATEELECTRICALWRAP END6" [15.2 cm]8 5/8" [21.9 cm]REFRIGERATION8 5/8" [21.9 cm]WIRING TO RACEWAY(STANDARD)ELECTRICAL72" [182.9 cm]96" [243.8 cm]120" [304.8 cm]144" [365.8 cm]3" [7.6 cm]NOTES*: STUB-UP AREA** : RECOMMENDED STUP-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS• Suction Line - 7/8", Liquid Line - 1/2"48" [121.9 cm]29 3/4" [75.6 cm]LOAD LIMIT LINE12" GLASS FRONT32 15/16" [83.7 cm]COIL PLENUM34 1/2" [87.7 cm]30 9/16" [77.6 cm]38 5/8" [98.2 cm]42 5/16" [107.4 cm]4 1/8" [10.5 cm]REAR REFRIGERATIONFOR PIPING TO OWIZV13 15/16" [35.5 cm]82 1/2" [209.6 cm](14 1/2" OFF OF FLOOR)7 1/2" [19.0 cm]11 3/16" [28.4 cm]REAR REFRIGERATIONFOR PIPING TO OWIZV(14 1/2" OFF OF FLOOR)ELECTRICALWIRING TORACEWAY(STANDARD)REFRIGERATION6 1/4" [15.8 cm]3 5/8" [9.2 cm]KICKPLATE1 1/2" PVCDRAINCONNECTION82 1/2" [209.6 cm]BASEFRAMEHORSELEG12" [30.4 cm]NOTES*: STUB-UP AREA** : RECOMMENDED SETUP-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS• Suction line - 7/8", Liquid line - 1/2"• Flat end-panel required when case is standalone43 13/16" [111.2 cm]42 5/16" [107.4 cm]38 9/16" [98.0 cm]34 7/16" [87.5 cm]35 15/16" [91.3 cm]15 9/16" [39.6 cm]29 3/4" [75.6 cm]26 3/8" [67.0 cm]11 1/2" [29.1 cm]24 5/8" [62.5 cm]36 1/16" [91.7 cm]3 11/16" [9.4 cm] 11 7/8" [30.1 cm] 1 1/2" [3.8 cm] 31 1/8" [79.1 cm] 24 1/4" [61.6 cm] 91 1/8" [231.5 cm] CASE HEIGHT TO WIRING BOX WITH CASTERS 87 7/8" [223.2 cm] CASE HEIGHT WITH CASTERS 85 5/8" [217.5 cm] CASE HEIGHT 64 5/8" [164.1 cm] INTERIOR HEIGHT 5 1/8" [13.0 cm] 28 5/8" [72.7 cm]* 14 1/2" [36.8 cm] 18 3/4" [47.6 cm] 59 13/16" [151.9 cm] VISUAL DISPLAY 88 7/8" [225.7 cm] CASE HEIGHT TO WIRING BOX 23 1/4" [59.1 cm] 3" [7.6 cm] 35 13/16" [91.0 cm] 28 1/8" [71.4 cm]**OPTIONAL WIRING TO THE TOP12in X 10in X 4in16"18"18"18"24 5/8" [62.5 cm]COILPLENUM137" [94.0 cm]LOAD LIMIT6 7/8" [17.5 cm]24 1/4" [61.6 cm]31 1/8" [79.1 cm]35 13/16" [90.9 cm]PIPING TO THE TOP(OPTIONAL)WIRING TO THE TOP(OPTIONAL)2" MINIMUM AIR GAP12" [30.5 cm]REAR REFRIGERATIONLOCATED 12 1/4" ABOVE FINISH FLOORELECTRICALJUNCTION BOX1 1/2" PVC DRAINCONNECTION48" [121.9 cm]72" [182.9 cm]96" [243.8 cm]144" [365.8 cm]NOTES:* : STUB-UP AREA** : RECOMMENDED STUP-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS:AVAILABLE SHELF SIZES: 10", 12", 14", 16", 18" & 20"1• Ends add approximately 1" to case height, 1/2" to the back and 1" to the front.1 1/2" [3.8 cm] END8 3/4" [22.2 cm]DEFAULT REFRIGERATIONOPTIONAL WIRINGTO THE TOP12 in X 10 in X 4 in39 5/8" [100.6 cm]LOAD LIMIT24 in24 in24 in24 in132" [81.3 cm]COILPLENUM31 3/4" [80.6 cm]6 3/8" [16.2 cm]38 7/8" [98.7 cm]43 1/4" [109.9 cm]WIRING TO THETOP (OPTIONAL)PIPING TO TOP(OPTIONAL)2" MINIMUM AIR GAP12" [30.5 cm]REAR REFRIGERATIONLOCATED 14 1/2" ABOVE FINISH FLOORDEFAULT REFRIGERATIONELECTRICALJUNCTION BOX1 1/2" PVC DRAINCONNECTION48" [121.9 cm]72" [182.9 cm]96" [243.8 cm]144" [365.8 cm]NOTES:* :STUB-UP AREA** :RECOMMENDED STUP-UP CENTERLINE FOR ELECTRICAL AND DRAINS :AVAILABLE SHELF SIZES: 10", 12", 14", 16", 18", 20", 22" & 24"• Ends add approximately 1" to case height, 1/2" to the back & 1" to the front• Back panels add approximately 1" to the rear of the case.1 1/2" [3.8 cm] END8 3/4" [22.2 cm]43 1/4" [109.9 cm] 38 7/8" [98.7 cm] 31 3/4" [80.6 cm] 91 1/8" [231.4 cm] SHIPPING HEIGHT WITH WIRING BOX 87 7/8" [223.2 cm] SHIPPING HEIGHT 85 5/8" [217.5 cm] CASE HEIGHT 63" [160.0 cm] INTERIOR HEIGHT 5 1/8" [13.0 cm] 28 5/8" [72.7 cm]* 14 1/2" [36.9 cm] 59 3/4" [151.8 cm] VISUAL DISPLAY 18 3/4" [47.6 cm] 88 7/8" [225.7 cm] CASE HEIGHT TO WIRING BOX 3" [7.6 cm] 22 3/4" [57.8 cm] 35 1/8" [89.4 cm]**1OPTIONAL WIRINGTO THE TOP12 in X 10 in X 4 in9" MIRROROPTIONALLOAD LIMIT16 in18 in20 in20 in132 1/4" [81.9 cm]COILPLENUM34 3/4" [88.2 cm]32 5/8" [82.9 cm]31 3/4" [80.6 cm]28 1/8" [71.4 cm]43 1/4" [109.9 cm]WIRING TO THETOP (OPTIONAL)2" MINIMUM AIR GAPPIPING TO THE TOP(OPTIONAL)12" [30.5 cm]REARREFRIGERATIONLOCATED 11 1/4"ABOVE FINISHFLOORDEFAULT REFRIGERATIONELECTRICALJUNCTION BOX1 1/2" PVC DRAINCONNECTION1 1/2" [3.8 cm] ENDNOTES:48" [121.9 cm]72" [182.9 cm]96" [243.8 cm]144" [365.8 cm]* : STUB-UP AREA** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND DRAINS:AVAILABLE SHELF SIZES: 10", 12", 14", 16", 18" & 20"• Ends add approximately 1" to case height, 1/2" to the back & 1" to the front.• Back panels add approximaely 1" to the rear of the case.8 3/4" [22.2 cm]43 1/4" [109.8 cm]86 5/16" [219.3 cm] SHIPPING HEIGHT5" BASEFRAME39 1/4" [99.7 cm]11" BASEFRAME32 5/8" [82.9 cm]11" [27.9 cm]REAR PIPE BOX84 3/16" [213.9 cm] OVERALL CASE HEIGHT80 7/8" [205.4 cm] CASE HEIGHT52 1/4" [132.7 cm] INTERIOR HEIGHT22 3/4" [57.8 cm]46 7/8" [119.1 cm] VISUAL DISPLAY27" [68.6 cm]28 1/2" [72.4 cm]*11" BASEFRAME13 1/4" [33.6 cm]**32 7/8" [83.6 cm]**5" BASEFRAME28 5/8" [72.7 cm]3" [7.6 cm]1139 5/8" [100.6 cm]OPTIONAL WIRINGTO THE TOP12 in X 10 in X 4 in20 in20 in20 in20 in1OPTIONAL DISCHARGEPLEXI DEFLECTORLOAD LIMIT32 1/4" [81.9 cm]COILPLENUM31 3/4" [80.6 cm]6 3/8" [16.2 cm]42 7/16" [107.8 cm]38 7/8" [98.7 cm]12" [30.5 cm]WIRING TO THETOP (OPTIONAL)2" MINIMUM AIR GAPPIPING TO THE TOP(OPTIONAL)REAR REFRIGERATIONLOCATED 14 1/2" ABOVE FINISH FLOORDEFAULT REFRIGERATIONELECTRICALJUNCTION BOX1 1/2" PVC DRAINCONNECTION1 1/2" [3.8 cm] END48" [121.9 cm]72" [182.9 cm]96" [243.8 cm]144" [365.8 cm]8 3/4" [22.2 cm]NOTES:* :STUB-UP AREA** :RECOMMENDED STUP-UP CENTERLINE FOR ELECTRICAL AND DRAINS:AVAILABLE SHELF SIZES: 10", 12", 14", 16", 18", 20", 22" & 24"• Ends add approximately 1" to case height, 1/2" to the back & 1" to the front.• Back panels add approximately 1" to the rear of the case.43 1/8" [109.5 cm] 38 7/8" [98.7 cm] 31 3/4" [80.6 cm] 91 1/8" [231.4 cm] SHIPPING HEIGHT 88 7/8" [225.7 cm] OVERALL CASE HEIGHT 85 5/8" [217.5 cm] CASE HEIGHT 63" [160.0 cm] INTERIOR HEIGHT 5 1/8" [13.0 cm] 29 1/8" [74.1 cm]* 29 3/4" [75.5 cm] 19 3/8" [49.2 cm] 54 7/8" [139.4 cm] VISUAL DISPLAY 3" [7.6 cm] 28 5/8" [72.7 cm] 35 15/16" [91.2 cm]**142" [106.7 cm]38 1/8" [96.8 cm]31 3/4" [80.6 cm]34 7/8" [88.6 cm]**87 1/2" [222.3 cm] SHIPPING HEIGHT85 1/4" [216.5 cm] OVERALL CASE HEIGHT81 1/4" [206.4 cm] CASE HEIGHT60 1/4" [153.0 cm] INTERIOR HEIGHT5 1/8" [13.1 cm]28 1/2" [72.4 cm]*59 5/8" [151.5 cm] VISUAL DISPLAY7 3/4" [19.7 cm]16 1/4" [41.3 cm]64 3/8" [163.5 cm] FRAME HEIGHT62 3/8" [158.4 cm] DOOR HEIGHT 3 1/4" [8.2 cm] 28 5/8" [72.7 cm]38 9/16" [97.9 cm]TOP WIRINGLOAD LIMIT27" [24]27" [24]27" [24]27" [24]27" [24]30 3/8" [77.2 cm]COIL PLENUM5 5/8" [14.3 cm]31 3/4" [80.7 cm]38 1/8" [96.9 cm]42" [106.7 cm]11" [27.9 cm]4" [10.2 cm]WIRING TO THE TOP(12" X 10" X 4")2" AIR GAP REQUIREDPIPING TO THE TOP(OPTIONAL)REAR REFRIGERATIONLOCATED 9 1/4" ABOVEFINISH FLOORDEFAULT REFRIGERATIONELECTRICALJUNCTION BOX(WIRING PERLOCAL CODES)1 1/2" PVC DRAIN CONNECTION31" [78.7 cm] (1 DOOR)60" [152.4 cm] (2 DOOR)90" [228.6 cm] (3 DOOR)120" [304.8 cm] (4 DOOR)150" [381.0 cm] (5 DOOR)180" [457.2 cm] (6 DOOR)NOTES* : STUB-UP AREA** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS• Ends add approximately 1" to case height, 1/2" to the back & 1" to the front8 3/4" [22.2 cm]1 1/2" [3.8 cm] END4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com ESTIMATED OPERATINGWEIGHT: 8300 LBS4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com EINSTEIN 2CX-400ETHERNET HUB SWITCH(LOCATED ONRACK)4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com U(96)FROMTOVFDCA FUSED DISCONNECT AS PER NATIONALNOTE: EQUIPMENT SHOULD BE POWERED THRUAND LOCAL ELECTRIC CODE.GAL1L2L31298CPC COMBO BOARDDANFOSS18COMMON0-10 VDC5553040512FAULTFAULT1311RUNRUN10CDEABTORQUE 16 LBS-IN.TORQUE 50-55 LBS-IN. (DISC)USE COPPER CONDUCTORSONLY RATED @ 60°C MINTORQUE 5.0-5.6 IN LBS (T-BLKS)ONLY RATED @ 60°C MINUSE COPPER CONDUCTORSONLY RATED @ 60°C MINUSE COPPER CONDUCTORSTORQUE TO 35 LBS-IN. (GND LUG)PROVIDED BY THE INSTALLERGREATER INSTALLED ANDMEANS RATED @ 45A ORU.L. LISTED DISCONNECTFIELD WIRE BY E.C.THIS PANEL ENCLOSURE IS RATED NEMA 3R.TO PRESERVE RATING USE NEMA 3R. CONDUIT ENTRY HUBSAO-AO+DISC.27AI VFDAI PROOFVFDC - VFD CONTACTORBC - BYPASS CONTACTORBR - BYPASS RELAYDDIP SWITCH SET FOR N/C OPERATIONV(97)W(98)L1(91)L2(92)L3(93)F4F5PC - PUMP CONTACTOR*VFDC & BC HARDWARE INTERLOCKEDFORWARDALARMRUNVFDC AUX67BCF1F3F2EFANCONTACTORUSE COPPER WIRE WITH 60 DEGC RATING MINIMUM1AUXVFDCBCGGICBR5BPAUXTD2(INLINE)ALOADOVER34(INLINE)TD1RUNROSWITCHBYPASSDIP SWITCHDOWN FORRUN OPERATIONTT2ROBYPASS"DIP SWITCHUP FOROPERATION"BYPASSRODIP SWITCHUP FORNORMAL OPERATIONFAN SWITCH & VFDFAN0201FAN MOTORBYPASS PROOF1415AICONDENSER PANELAIR COOLEDL1L2L3DISC.VFDVFDVFDOVERLOADPROTECTIONSEE ELECTRICALSCHEDULE FORVOTAGESEE ELECTRICALSCHEDULE FORVOTAGESEE ELECTRICALSCHEDULE FORVOTAGESEE RS FOR TOTALFANS & HPL1L2DISC.FAN CONTROLDISC.AUXAUX6TORUN INSEPARATECONDUITNOTE: COND. DISC. AUX TOBE WIRED TO THEN.O. CONTACT IN THEOFF POSITION, RUNIN LOW VOLTAGENETWORK CONDUIT.4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com 120G4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com TO VAC CENTRALBC DFGA112233445566E4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com WEIGHT 67lbs (31kg)BRACING (TYPICAL)TO 2" VACUUM CENTRAL INLET2" PIPE15.4" (38cm)58" (150CM)3" PVC PIPE SOCKETMUST BE ATTACHED TO ASTRUCTURAL CEILING SUPPORTVACUUM MAINMAY BE 2", 3" OR 4" PIPE3" PIPE4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com APPROVALSUL US LISTED, IAPMO, NSF,UPC, NSPC, IPC,CE.TO 2" VACUUM CENTRAL INLET2" PIPE15.4" (38cm)58" (150CM)3" PVC PIPE SOCKETMUST BE ATTACHED TO ASTRUCTURAL CEILING SUPPORTVACUUM MAINMAY BE 2", 3" OR 4" PIPE3" PIPEWEIGHT 67lbs (31kg)BRACING (TYPICAL)4275 N Palm St, Suite 100 Fullerton, CA 92835 (714) 578-2300 office www.coolsysenergydesign.com