20160220162635 Blower Door Test Palisades Lot 214/ 2-0 17 e 7, /
'0A00.VeeA*1
MAG E■___LAN
Insulation Certificate / Attic Card / SLA Testing
Batts and Blankets Thermal Performance (Attic Application)
When installed in accordance with the manufacturers The stated thermal resistance (R -value) is provided by installing in accordance with the manufactuers instructions, the required number of bags
recommendations, Knauf baits and blankets will provide per 1,000 sq,fl of net area, at not less than the labeled minimum thickness. Failure to install both the required number of bags and at least the
the full R -value. minimum thickness will result in lower insulation R -value.
9 -Value*
Minimum Thickness
To Obtain An insulation
resistance (R -Value) of:
Installed insulation should not
be less than:
R-38HD
10.25"
R-38HD
12.00"
R-30HD
8.25"
R-30
10.00"
R-26
9.00"
R-22
6.50"
R-21 HD
5.50"
R-19
6.25"**
R-15HD
3.50"
R-13
3.50"
R-11
3.50"
R-8
2.50"
"R-18 in a 5.5" cavity Conforms to ASTM C665 and
Federal Specification 1-1H-1-5211'.
R•Vafue'
Ba s11 000.s . ft.
Maximum Covera O
Minimum Wei tit
Minimum Thickness
To Obtain an insulal ion
resistance (R -Value) of:
The number of
bags/1,000 SF of net
area should not be less
Contents of this bag should not The weighllSF of installed
cover more than: insulation should not be
less than:
Installed insulation should
not be less than:
R-60
31.7
31.5 SF
.952 LBS
19.75"
R-50
25.8
38.7 SF
774 LBS
16-75"
R-44
22.1
45.3 SF
.663 LBS
14.75"
R-38
19.0
52.7 SF
.569 LBS
13.00"
R-30
14.4
69.7 SF
431 LBS
10.25"
R-26
12.4
80.9 SF
-371 LES
9.00"
R-22
10.4
95-8 SF
313 LBS
7.75"
R-19
8.9
111.8 SF
.268 LBS
6.75"
R-13
6.1
164-3 SF
183 LBS
14.75"
R-11
5.1
197-6 SF
152L S
1 4.00"
Bag Weight - Nominal 30 lbs., Minimum 29 Ihs. This product comforms to the performance requirements of ASTM C 764, Type I, and cancelled
Federal Specification HH -1-10308, Type I, Class B. R -Values are determined in accordance with C 687 and C 516. "R" means resistance to
heal flow. The higher the R -value, the greater the insulation power. To get the marked R -value, it is eseential that the insulation be installed
properly. If you do it yourself, get instructions and follow them carefully.
2016 YVSEC Residential Energy Compliance Certificate - Building Air Leakage
Building Air Leakage target SLA Less than 0.00030
Tested Leakage SLA: = .00027
Darrin Baasch PTCS 3143 AC1HR 3.6
Framing Adjustment
To compensate for framing members, the number of bags per 1,000 sq ft of area to be
insulated should be as shown below.
R -Value
Joist
Dimentions
W..Valuo
Standard
Attic Area
2x4
R-49
R-49
Sloped Ceilings
2x6
R-38
R-38
Walls
IR
R-21
R-21
Floors (over an unheated crawl space
R-30
R-30
25.2
2x8
24.6
Completed as of:
101912018
2x4
21.5
Site Address:
Palisades Lot 21
2x6
21.2
21.5
10797 Palisades St SE
2x8
20.9
21.2
Yelm, WA 98597
2x4
18.4
Home Builder
R-38
2x6
18.1
Signature:
2x8 17.8
18.2
Home Builder
Northwest Family Homes
14.0
R-30
Address:
P.O. BOX 39
13.8
2x8
Olympia, 98501
13.6
R-26
Insulation
11.9
12.0
2x6 11.6
Contractor:
Magellan Insulation
2x8
11.3
11.6
22706 58th Place South
2x4
9.9
10.1
Kent, WA 98032
2x6
9.7
Framing Adjustment
To compensate for framing members, the number of bags per 1,000 sq ft of area to be
insulated should be as shown below.
R -Value
Joist
Dimentions
Bags/MSF 16" O.C.
Framing
BagsIMSF 24" O,C.
Framing
2x4
31.2
31.3
R-60
2x6
30.8
31.1
2x8 30.5
30.8
R-50
2x4
25.3
25.4
2x6 25.0
25.2
2x8
24.6
25.0
2x4
21.5
21-7
R-"
2x6
21.2
21.5
2x8
20.9
21.2
2x4
18.4
18.6
R-38
2x6
18.1
18.4
2x8 17.8
18.2
2x4
13.8
14.0
R-30
2x6
13.5
13.8
2x8
13.3
13.6
R-26
2x4
11.9
12.0
2x6 11.6
11.8
2x8
11.3
11.6
2x4
9.9
10.1
R-22
2x6
9.7
9.9
2x8
9.7
9.7
2x4
8.5
8.6
R-19
2X6
8.2
8.4
2x8
7.9
8.2
2x4
5.6
5.8
R-13
2x6
5.4
5.6
2x8
5.1
5.4
2x4
4.6
4-7
R-11
2x6
4.3
4.5
2x8
4.1
4.3