20160220162635 Blower Door Test Palisades Lot 214/ 2-0 17 e 7, / '0A00.VeeA*1 MAG E■___LAN Insulation Certificate / Attic Card / SLA Testing Batts and Blankets Thermal Performance (Attic Application) When installed in accordance with the manufacturers The stated thermal resistance (R -value) is provided by installing in accordance with the manufactuers instructions, the required number of bags recommendations, Knauf baits and blankets will provide per 1,000 sq,fl of net area, at not less than the labeled minimum thickness. Failure to install both the required number of bags and at least the the full R -value. minimum thickness will result in lower insulation R -value. 9 -Value* Minimum Thickness To Obtain An insulation resistance (R -Value) of: Installed insulation should not be less than: R-38HD 10.25" R-38HD 12.00" R-30HD 8.25" R-30 10.00" R-26 9.00" R-22 6.50" R-21 HD 5.50" R-19 6.25"** R-15HD 3.50" R-13 3.50" R-11 3.50" R-8 2.50" "R-18 in a 5.5" cavity Conforms to ASTM C665 and Federal Specification 1-1H-1-5211'. R•Vafue' Ba s11 000.s . ft. Maximum Covera O Minimum Wei tit Minimum Thickness To Obtain an insulal ion resistance (R -Value) of: The number of bags/1,000 SF of net area should not be less Contents of this bag should not The weighllSF of installed cover more than: insulation should not be less than: Installed insulation should not be less than: R-60 31.7 31.5 SF .952 LBS 19.75" R-50 25.8 38.7 SF 774 LBS 16-75" R-44 22.1 45.3 SF .663 LBS 14.75" R-38 19.0 52.7 SF .569 LBS 13.00" R-30 14.4 69.7 SF 431 LBS 10.25" R-26 12.4 80.9 SF -371 LES 9.00" R-22 10.4 95-8 SF 313 LBS 7.75" R-19 8.9 111.8 SF .268 LBS 6.75" R-13 6.1 164-3 SF 183 LBS 14.75" R-11 5.1 197-6 SF 152L S 1 4.00" Bag Weight - Nominal 30 lbs., Minimum 29 Ihs. This product comforms to the performance requirements of ASTM C 764, Type I, and cancelled Federal Specification HH -1-10308, Type I, Class B. R -Values are determined in accordance with C 687 and C 516. "R" means resistance to heal flow. The higher the R -value, the greater the insulation power. To get the marked R -value, it is eseential that the insulation be installed properly. If you do it yourself, get instructions and follow them carefully. 2016 YVSEC Residential Energy Compliance Certificate - Building Air Leakage Building Air Leakage target SLA Less than 0.00030 Tested Leakage SLA: = .00027 Darrin Baasch PTCS 3143 AC1HR 3.6 Framing Adjustment To compensate for framing members, the number of bags per 1,000 sq ft of area to be insulated should be as shown below. R -Value Joist Dimentions W..Valuo Standard Attic Area 2x4 R-49 R-49 Sloped Ceilings 2x6 R-38 R-38 Walls IR R-21 R-21 Floors (over an unheated crawl space R-30 R-30 25.2 2x8 24.6 Completed as of: 101912018 2x4 21.5 Site Address: Palisades Lot 21 2x6 21.2 21.5 10797 Palisades St SE 2x8 20.9 21.2 Yelm, WA 98597 2x4 18.4 Home Builder R-38 2x6 18.1 Signature: 2x8 17.8 18.2 Home Builder Northwest Family Homes 14.0 R-30 Address: P.O. BOX 39 13.8 2x8 Olympia, 98501 13.6 R-26 Insulation 11.9 12.0 2x6 11.6 Contractor: Magellan Insulation 2x8 11.3 11.6 22706 58th Place South 2x4 9.9 10.1 Kent, WA 98032 2x6 9.7 Framing Adjustment To compensate for framing members, the number of bags per 1,000 sq ft of area to be insulated should be as shown below. R -Value Joist Dimentions Bags/MSF 16" O.C. Framing BagsIMSF 24" O,C. Framing 2x4 31.2 31.3 R-60 2x6 30.8 31.1 2x8 30.5 30.8 R-50 2x4 25.3 25.4 2x6 25.0 25.2 2x8 24.6 25.0 2x4 21.5 21-7 R-" 2x6 21.2 21.5 2x8 20.9 21.2 2x4 18.4 18.6 R-38 2x6 18.1 18.4 2x8 17.8 18.2 2x4 13.8 14.0 R-30 2x6 13.5 13.8 2x8 13.3 13.6 R-26 2x4 11.9 12.0 2x6 11.6 11.8 2x8 11.3 11.6 2x4 9.9 10.1 R-22 2x6 9.7 9.9 2x8 9.7 9.7 2x4 8.5 8.6 R-19 2X6 8.2 8.4 2x8 7.9 8.2 2x4 5.6 5.8 R-13 2x6 5.4 5.6 2x8 5.1 5.4 2x4 4.6 4-7 R-11 2x6 4.3 4.5 2x8 4.1 4.3