2020.0103.BPP0008 0100 - A3 SECTIONS AND DETAILS - 3705AAGYP BD WALLCMU WALLWALL STANDARDSPACING PER FINALMERCHANDISE PLANBASE DECK (FIXTURE)3/8"x 3" LAG BOLTSPACE AT 24" OCVERTICALLYEXISTING BLOCKINGINSERT 5/16"x1-1/2"ELEVATOR BOLT INTOPREDRILLED HOLEFROM BACK OFFURRING STRIPEXISTING WALL2"x3/4" PLYWOOD FURSTRIPS. WALL STANDARDSPACING PER FINALMERCHANDISE PLANPEG BOARD BETWEENSHELF STANDARDSSHELFSTANDARDSMOUNTED ONFURRING STRIPSADHESIVE APPLIED TOBACK OF PLYWOODFURRING STRIPBUILDING WALL2"x3/4" PLYWOOD FURRINGSTRIPS. WALL STANDARDSPACING PER FINALMERCHANDISE PLANPEG BOARDINSERT 5/16"x1-1/2"ELEVATOR BOLT INTOPREDRILLED HOLE FROM BACKOF FURRING STRIPSHELF STANDARD MOUNTEDON FURRING STRIPS3" POWDER ACTUATEDFASTENERBASE DECK (FIXTURE)POWDER ACTUATEDFASTENER SPACEDEVENLY. APPLY EVERYSECOND BLOCK ATCENTERLINE OF BLOCKTOP OF STANDARD96" AFFTOP OF STANDARD96" AFFFLOOR FINISH ASSCHEDULEDPAINT CMU FROMFINISH FLOOR TODECK ASSCHEDULEDPAINT GIRDER ORJOIST DIRECTLYADJACENT TO WALLTO MATCH. COLORAS INDICATEDPAINT COLUMN TOMATCH ADJACENTWALL AS INDICATEDNOTE: DO NOT PAINT ABOVE CEILING100'-0"FF ELGRIDTO DECKDELISALESCEILING AS SCHEDULEDP131P131P131EXISTINGBULKHEADREFRIGERATEDCASE EXISTING METALSTUDSPAINT 6" BEHINDTOP AND SIDESOF REFRIGERATEDCASES.P131P131P1314" SANDCUSHIONCONDUITOR PIPEDOWELING TO BE AMAXIMUM OF 6"FROM EDGE OF NEWCONCRETE INFILL1/2" DIA X 1'-0" SMOOTHDOWEL EMBEDDED 6" INTOEXISTING SLAB AT 18" OC.PROVIDE MIN (2) DOWELSEACH SIDE OF TRENCHWHEN INFILLING OVERTRENCH, 1/2 OF TRENCHWIDTH (12" MAX) EACH SIDECONCRETE SLAB TOMATCH ADJACENTMATCH EXISTING(4" MIN)AGGREGATE BASEEXISTINGCONCRETEPLAN6"MAX6"MAXCONDUIT AND SAND CUSHION ONLY APPLY WHEN INFILLING OVER TRENCH. DEPTH TO BE DETERMINED PER FIELD CONDITIONS AND LOCAL CODES. EQEQ.REF STRUCTURALarchitecture2809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209+engineeringArchitect of RecordWilliam Douglas HurleyWashington License No. 8855Unified Business ID No. 602 491 668STIPULATION FOR REUSETHIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DRAWN BY:CHECKED BY:DOCUMENT DATE:PROTO:SUPER BUNDLEPROTO CYCLE:DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTIONSHEET:ISSUE BLOCKYELM, WASHINGTON03/11/2020YELM, WASHINGTONSTORE NO.3705-232JOB NUMBER: 2019.0835ECJT17601/31/202003/11/2020SECTIONSAND DETAILSA3 12" = 1'-0"1WALL STANDARD MOUNTING 1/4" = 1'-0"2EXISTING EXT CMU WALL SECTION 1" = 1'-0"3SECTION AT DELI BULKHEAD 1/2" = 1'-0"4BULKHEAD AT CASE 3/4" = 1'-0"5SLAB INFILL DETAIL