Loading...
2020.0103.BPP0008 0110 - A4 ROOF PLAN AND DETAILS - 3705CONT EDGE SEALANT AS REQUIRED BY ROOF MFREXISTING ROOF MEMBRANE OVER INSULATIONNEOPRENE GASKETEDFASTENERS @ 12" OCMETAL CAP, CHANNEL, AND UNISTRUT PROVIDED BY AND INSTALLED BY CURB MANUFACTURERFULLY ADHERED FLASHING MEMBRANE EXTEND UP TO TOP OF CURBBATT INSULATION CONTINOUS SEALANTCONDENSING UNIT, REF REFRIGERATION AND MEPIN-FILL INSULATION AS NEEDEDSTEEL CHANNEL REF STRUCTEXISTING ROOF DECKSTEEL CURB REF SPECAND2x4 TREATED WOOD NAILERINSULATION BY GCUNISTRUT AND ATTACHMENT PROVIDED BY CURB MANUFACTURER, INSTALLED BY GCREF MANUFACTURER FOR CONDENSING UNIT ATTACHMENT-REF3A4DECKINSULATION BYGENERAL CONTRACTOR2x4 TREATEDWOOD NAILERDECKINSULATION BYGENERAL CONTRACTOR2x4 TREATEDWOOD NAILERDECKINSULATION BYGENERALCONTRACTOR2x4 TREATEDWOOD NAILER3/16" DIAMETER GRIDDECKINSULATION BYGENERALCONTRACTOR2x4 TREATEDWOOD NAILERSKYLIGHT CURBSTRUCTURAL CURBSTRUCTURAL CURB (AHU)NON-STRUCTURAL CURB2"3/8"3"VARIESREF SPECSVARIESREF SPECS1/2"1/2"3"1 3/4"3/8"2"2"3"VARIESREF SPECS2"3/8"VARIESREF SPECS3"PROVIDE SINGLE ROW OF WALKWAY PADS ON ACCESS SIDE OF UNIT.FIELD VERIFY LOCATIONRCURCUNOTE: DO NOT INSTALLWALK WAY PADS UNTILROOF PENETRATIONFLASHINGS ARE COMPLETE.NOTE: FOR ROOFPENETRATIONS LOCATED WHEREWALKWAY PADS ARE INSTALLED,TRIM WALKWAY PADS 4" FROMEDGE OF ROOF PENETRATIONFLASHING BEFORE PADINSTALLATION.PROVIDE CRICKET AT ALL MECHANICALEQUIPMENT, SKYLIGHTS, RTU'S, ETC. INSTALL ROOFING INSULATION WITH 1/2" PER FOOT SLOPE TO PROVIDE POSITIVE DRAINAGE AROUND UNITS.VIEWPLAN11"EXIST JOIST3"x3"x1/4"ANGLEPIPE STRAPS TYPEACH PIPE ORCONDUITROOF SYSTEM ANDSTEEL DECKINGGALVANIZED METAL CAPW/ HOOD AT PIPEPENETRATIONS10"2"MANUFACTURED CURBSLOPE 1/4" PER FT.TAPER HOODVERTICAL PIPING ANDCONDUIT TO BE ATTACHEDTO ANGLE. REFER TOPIPING/CONDUIT SUPPORTDRAWINGS FOR CLAMPREQUIREMENTS.3"x3"x1/4" ANGLE. WELD TOTOP CHORD OF JOIST WITH1/8"x2" FILLET WELDTYP. BOTH ENDS2" INSULATION BOARD#12x2" SS SCREWSWITH NEOPRENE/SS BONDED WASHER AT 8" OCFULLY ADHERED FLASHINGMEMBRANE EXTEND UP ANDOVER TOP OF CURBROOF MEMBRANECONT EDGE SEALANT IF REQUIRED BY MFRINSULATION (TYP)FASTENER AND PLATEOPENING FORREFRIGERATION LINES ANDCONDUIT. COORDINATELOCATION W/REFRIGERATION EQUIPMENT.INSULATED REFRIGERATIONLINES AND CONDUIT MOUNTEDTO UNISTRUT; UNISTRUT TOBE ATTACHED TO CURBBATT INSULATIONTO REFRIGERATIONEQUIPMENT REFREFRIGERATION DRAWINGSFOR SIZE OF PIPESCONTINUOUSSEALANT ALLSIDES ANDPENETRATIONSPERIMETER TYPINSTALL UPPERPLATE TO OVERLAPBOTTOM PLATE ONEXTERIOR SIDE WITH1" MIN PLATEOVERLAPPLAN VIEWOPENING FORREFRIGERATION LINES ANDCONDUITPAINT TO MATCHADJACENT STRUCTUREMAINTAIN 1/2"CLEARANCE FROM PIPEAND INSULATION BOARDINSULATION BOARDPLATE TO OVERLAPCURB 1" MIN1.2.3.4.INSTALLATION NOTES:THE ROOF PENETRATION CURB, HOOD AND CLOSURE PLATES ARE FURNISHED BY OWNER AND INSTALLED BY GENERAL CONTRACTORALL HOOD PENETRATIONS SHALL BE THROUGH THE VERTICAL CLOSURE PLATES ONLY. PIPING AND CONDUIT SHALL BE INSTALLED BY THE TRADE CONTRACTORS WITH THE PIPE AND CONDUIT CENTERLINES 5" ABOVE THE TOP OF THE ROOF CURB WITH A MINIMUM OF 1" BETWEEN THE PIPE AND CONDUIT EXTERNAL SURFACETHE GENERAL CONTRACTOR SHALL CUT AND INSTALL THE VERTICAL CLOSURE PLATES AFTER ALL PIPING AND CONDUITS ARE INSTALLED AND SEAL ALL PENETRATIONS AS NOTED IN THE DETAIL AND PROVIDE CONTINUOUS SEALANT AT THE PERIMETER JOINT BETWEEN THE CLOSURE PLATES AND HOOD AND CURB AND WHERE THE CLOSURE PLATES OVERLAP. REF SEALANT SPECIFICATION. EXPANDING FOAM SEALANT SHALL NOT BE USED WHERE SEALANT IS EXPOSED TO THE EXTERIOR.EXTEND EXTERIOR REFRIGERANT AND WATER LINE EXTERNAL PVC INSULATION JACKET 1" INSIDE HOOD METAL CLOSURE PLATES.12" CLEAR2"12" MIN5"1/8" 2"1/8" 2"CLEAR INSIDE OPENINGX"2 PIECE GALVANIZED METAL VERTICAL CLOSURE PLATES, INSTALLED BY GC. FIELD CUT TO FIT AROUND CONDUIT AND PIPE INSULATION (1/8" MAX. GAP BETWEEN PIPE/CONDUIT AND PLATE), FASTEN TO HOOD AND CURB WITH SHEET METAL SCREWS W/NEOPRENE WASHERS 4 EA SIDE AND 6" OC TOP AND BOTTOMDIMENSIONS FOR X"2 REFRIG LINES - 12" MIN3 REFRIG LINES - 16" MIN4 REFRIG LINES - 20" MIN5 REFRIG LINES - 24" MINREF REFRIGERATION DRAWINGS FOR NUMBER OF LINESROOF LEGENDEXISTING SKY LIGHTEXISTING EXHAUST FANNEW RCU12345ABCDEFGHJNEW RCU-1 MOUNTED ON ROOF.REF STRUCT, MEP &NEW REFRIGERATION PIPE CHASE. REF STRUCTURE-REF4A4NEW REFRIGERATION PIPE CHASE. REF STRUCTURE-REF4A4NEW RCU-2 MOUNTED ON ROOF.REF STRUCT, MEP &-REF2A4-REF2A4architecture2809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209+engineeringArchitect of RecordWilliam Douglas HurleyWashington License No. 8855Unified Business ID No. 602 491 668STIPULATION FOR REUSETHIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DRAWN BY:CHECKED BY:DOCUMENT DATE:PROTO:SUPER BUNDLEPROTO CYCLE:DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTIONSHEET:ISSUE BLOCKYELM, WASHINGTON03/11/2020YELM, WASHINGTONSTORE NO.3705-232JOB NUMBER: 2019.0835ECJT17601/31/202003/11/2020ROOF PLANAND DETAILSA4 1 1/2" = 1'-0"2CONDENSER UNIT CURB 1 1/2" = 1'-0"3CURB 12" = 1'-0"5PAD LAYOUT (TYP ALL UNITS) 1" = 1'-0"4REFRIGERATION LINE ROOF PENETRATION 1/16" = 1'-0"1PARTIAL REFLECTED CEILING PLANNORTH