Loading...
2020.0103.BPP0008 0170 - GA1 FRONT GROCERY PLAN - 3705T A BLET A BLEPIZZAPANS5-SBAK7165-SBAK7165-SBAK7165-SBAK7165-SBAK7165-SBAK7165-SBAK716PASTRYINLINE CASE5-SBAK7165-SBAK71612"x48"KNEE KNOCKER12"x48"KNEE KNOCKER12"x48"KNEE KNOCKER12"x48"KNEE KNOCKER12"x48"KNEE KNOCKER12"x48"KNEE KNOCKER23C901SERVICEDELI900GROCERYSALES906BAKERY902DELI PREPRD4043.042DELIRD4043.042DELIRD4043.042DELIHOT DELIRH0122.000HOT DELIRH0135.000RD9009.005DELIINSTALL CASE FLASHING AT ALL NEW AND EXISTING CASESRELOCATED SLICERS ON MOBILE TABLES, TYPEXISTING CASERELOCATED SCALE, TYPNEW MERCH LAYOUT. REF FXS1 AND STORE LAYOUTVERIFY EXACT LOCATION OF CASES WITH WALMART CONSTRUCTION MANAGER PRIOR TO STARTING CONSTRUCTION. (TYP)PATCH AND REPAIR WALLS AND FINISHES TO MATCH ADJACENT WHERE IMPACTED BY INSTALLATION OR MODIFICATION OF PLUMBING AND/OR ELECTRICAL UTILITIESPATCH, REPAIR OR REPLACE EXISTING SUBSTRATE AT LOCATIONS OF REMOVED FINISHES FOR INSTALLATION OF NEW TILE. IF NEW SUBSTRATE IS REQUIRED, INSTALL 1/2" WATER RESISTANT GYPSUM BOARD.D102D007BD007AD007BD007AD007BD007ANEW SINK REF MEPSS006LRW507W506EXISTING SELF-CONTAINED PRODUCE CASE-REF1GA3SHEET NOTES5.6.7.8.9.PROPER INSTALLATION OF JOINT SEALANTS IS CRITICAL TO MEETING WALMART QUALITY ASSURANCE STANDARDS. PROVIDE SEALANTS IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS. REFERENCE SECTION 07900 FOR SEALANT SCHEDULEALL JOINTS BETWEEN DISSIMILAR MATERIALS SHALL BE SEALED AS REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, REGARDLESS OF WHETHER SHOWN ON THE DRAWINGS OR INDICATED IN THE SPECIFICATIONS. SUCH JOINTS NOT SHOWN OR SCHEDULED SHALL BE SEALED WITH SEALANTS AS RECOMMENDED BY THE MANUFACTURER FOR THE SPECIFIC APPLICATION.INTERIOR SEALANTS USED IN FOOD PREPARATION AREAS SHALL MEET THE REQUIREMENTS FOR USE IN USDA REGULATED FACILITIESPROVIDE STEEL CLOSURE PANELS AT ALL VERTICAL GAPS AND HORIZONTAL GAPS 52" OR LOWER BETWEEN REFRIGERATED CASES, WALLS AND/OR EQUIPMENT. COORDINATE REMOVAL AND DISPOSAL OF EXISTING REFRIGERATED CASES AND FIXTURES WITH MECHANICAL SERVICES CONSTRUCTION MANAGER. COORDINATE REMOVAL AND DISPOSAL OF EXISTING REFRIGERATED CASES AND FIXTURES WITH INSTALLATION OF NEW REFRIGERATED CASES AND FIXTURES EXISTING REACH-IN FROZEN CASES TO BE RELOCATED OR REMOVED SHALL BE USED ON A TEMPORARY BASIS DURING CONSTRUCTION OF NON-SERVICE SEAFOOD AREA. TEMPORARY CASES SHALL BE REMOVED ONCE THE NEW CASES ARE DELIVERED AND OPERATIONAL.10.11.12.13.DIMENSIONS OF REFRIGERATED CASES ARE TO THE OUTERMOST POINTS OF THE CASES; ENDCAPS AND BUMPERS ARE CONSIDERED PART OF THE CASE, WHERE THEY OCCUR. DIMENSIONS ON THE FIXTURE PLANS ARE FOR LAYOUT AND OWNER-FURNISHED ITEMS ONLY AND ARE NOT TO BE USED FOR LOCATION OF WALLS AND OTHER CONTRACTOR-BUILT ITEMSALL NEW (NON-MOVEABLE) EQUIPMENT INCLUDING SINKS, OVENS, AND REFRIGERATED EQUIPMENT SHALL BE SEALED TO THE WALLS. BASE OR LEGS SHALL BE SET IN A BED OF SEALANT WITH EXCESS REMOVED. MOVEABLE EQUIPMENT SHALL NOT BE SEALED.RE-SKINNING OF EXISTING CASES TO REMAIN UNDER SEPARATE CONTRACT.VERIFY EXACT LOCATION OF CASES WITH WALMART AND CM PRIOR TO STARTING CONSTRUCTION.1.2.a.b.c.STUD WALL DIMENSIONS ARE TO THE FACE OF THE STUDS.ROUTE ALL UTILITY SERVICE LINES (PIPES AND CONDUIT) WITHIN STUD WALLS WHEREVER POSSIBLE. ON COOLER/FREEZER PANELS IN FOOD PREP AREAS WHERE UTILITIES MUST BE EXPOSED, CONTRACTOR TO HAVE THE OPTION OF THE FOLLOWING: SURFACE MOUNT UTILITIES WITH NON-CORROSIVE ANCHORS; SEAL BOTH SIDES OF PIPE/CONDUIT TO PANEL CONTINUOUSLY WITH SEALANT. INSTALL UTILITIES 1/2" OFF FACE OF PANEL TO ALLOW FOR CLEANING; USE ONLY NON-CORROSIVE MATERIALS FOR SPACERS AND ANCHORS.COVER UTILITIES WITH 20 GAUGE STAINLESS STEEL BENT PLATES MOUNTED TO WALL WITH NON-CORROSIVE ANCHORS; APPLY CONTINUOUS SEALANT ALONG EDGES AND JOINTS.EQUIPMENT NOTES5. FINISHES FOR OWNER SUPPLIED EQUIPMENT ARE SPECIFIEDPER BID ALIGNMENT BETWEEN OWNER AND OEMGENERAL EQUIPMENT NOTESA.B.C.D.ALL EQUIPMENT IS SUPPLIED BY OWNER, INSTALLED BY THE GENERAL CONTRACTOR, GENERAL CONTRACTOR TO MAKE FINAL UTILITY CONNECTIONS, UNLESS OTHERWISE NOTEDREFERENCE SPECIFICATIONS FOR REFRIGERATED AND HOT DISPLAY CASES FOR SUPPLIED BY, INSTALLED BY, AND FINAL CONNECT BYREFERENCE SPEC APPENDIX A FOR MANUFACTURER AND MODEL NUMBERS NOT LISTED IN EQUIPMENT LEGENDSOWNER TO SUPPLY SS FIXTURES BY WIN-HOLT- USE SHORT OR RECTANGULAR WEDGES FOR ADA PASS THRU WEDGES- USE SHORT WEDGE, UNLESS BETWEEN TWO TALL CASES- SELECT WEDGE WIDTH TO MAXIMIZE PREFABRICATED (MERCHANDISABLE) PORTION OF WEDGE, BUT ACCOUNT FOR THE MAX/MIN CRITERIA BELOW - ADJUST OUTER DEPTH, LEFT AND RIGHT PANEL SIDE SCRIBE WIDTH AS NEEDED TO FIT BETWEEN CASES - FAMILIES ARE AVAILABLE IN THE STARTUP TOOLS THAT ARE ADJUSTABLE. - USE FILLER PANELS (13-GA-3.2 IN THE STARTUP TOOLS) IN LIEU OF WEDGE IF 1'-6" WEDGE WILL NOT FIT.SHORT2'-10" HTALL6'-6" H1'-6" W2'-0" W3'-0" WW500W502W504W501W503W505WEDGE SELECTION CHARTABC2" MIN - 12" MAX(OR OMIT)48" MAX20" MAXFIELD CUT PANELS2" MIN - 12" MAX(OR OMIT)48" MAX32" MAX1'-6" ALL OPTIONS2'-0" ALL OPTIONS3'-0" SHORT OPTIONSBC1'-6", 2'-0" OR 3'-0"FIXEDTOP PANEL(ENSURE EXTENTS OF ENTIRE WEDGE ASSEMBLY FITS WITHIN OVERALL TOP PANEL DIMENSIONS. CONTRACTOR WILL BE FIELD CUTTING TO SIZE)AF V 48"REF CUTSHEETVARIESDOES NOT HAVE TO BE EQUAL ON EACH SIDEIDEAL TO BE EQUAL ON EACH SIDE, BUT NOT REQUIRED3'-10" WN/AN/ARECTANGULAR2'-10" HN/AN/AW507W5063'-0" RECTANGULAR3'-10" RECTANGULAR2" MIN - 12" MAX(OR OMIT)2" MIN - 12" MAX(OR OMIT)26" MAX60" MAX26" MAX70" MAXPREFABRICATED UNIT - DO NOT MODIFYFIELD CUT TOP PANEL TO MATCH FOOTPRINT BELOW. TOP PANEL SHOULD BE TIGHT AND ALIGN WITH ADJACENT CASES, FIXTURES, ETC. PLANPREFABRICATED UNIT - DO NOT MODIFYFIXEDFIELD CUT TOP PANELFIELD CUT SIDE SCRIBES TIGHT TO ADJACENT FIXTURES, CASES, ETC. DO NOT LEAVE ANY GAPS.REF PLAN FOR ADJACENT FIXTURE, CASE, ETCINFILL ALL EXPOSED SIDE/GAPS WITH 5/8" BLACK PLAS-TEX PANEL BY PARKLAND PLASTICS, 5/8" BLACK HDPE, OR DROPS FROM WEDGE KITREF PLAN FOR ADJACENT FIXTURE, CASE, ETCELEVATIONSIDE SCRIBES, INSET FROM ADJACENT FIXTURE, CASE, ETC TO ENSURE ALL GAPS ARE CLOSED OFFFIELD CUT BACK PANEL TO BE TIGHT AND ALIGN TO THE BACK OF THE ADJACENT FIXTURES, CASES, ETC PROVIDE CONTINUOUS SEALANT BETWEEN WEDGE AND ADJACENT FIXTURES, CASES, ETC. AND FLOORATTACH PREFABRICATED UNIT, PANELS, AND SIDE SCRIBES AS REQUIRED USING SCREWS AND BRACKETS PROVIDED IN WEDGE KIT(OR OMIT)2" MINIF SIDE SCRIBE OMISSION IS REQUIRED ADJUST PREFABRICATED UNIT LOCATION TO REMOVE GAPPLACE BACK PANEL FOR SUPPORT OF TOP PANELALT PLANFIELD CUT TOP PANEL TIGHT TO ADJACENT FIXTURE, CASE, ETC EQEQALT PLANFIELD CUT TOP AND BACK PANEL TIGHT TO ADJACENT FIXTURE, CASE, ETC STAINLESS STEEL EQUIPMENT LEGENDSS06LR1HAND SINK 16X14 (14X10) PEDESTAL WITH RH SPLASHarchitecture2809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209+engineeringArchitect of RecordWilliam Douglas HurleyWashington License No. 8855Unified Business ID No. 602 491 668STIPULATION FOR REUSETHIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DRAWN BY:CHECKED BY:DOCUMENT DATE:PROTO:SUPER BUNDLEPROTO CYCLE:DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTIONSHEET:ISSUE BLOCKYELM, WASHINGTON03/11/2020YELM, WASHINGTONSTORE NO.3705-232JOB NUMBER: 2019.0835ECJT17601/31/202003/11/2020FRONTGROCERYPLANGA1 1/8" = 1'-0"1FRONT GROCERY PLANREFRIGERATED CASE LEGENDWDS NUMBER QTY.CASELENGTH/DOOR NO.DESCRIPTIONMFR OR SUPPLIERMODEL NO. NOTESRD4043.042 1 8FT MULTI-DECK (BOTTOM FED)HILL PHOENIX, INC.ON5DMX-NRG5RD4043.042 2 12FT MULTI-DECK (BOTTOM FED)HILL PHOENIX, INC.ON5DMX-NRG5RD4046.452 2 6FT MULTI-DECK ISLAND CENTER (TOP FED)HUSSMANN CORPORATIONIM-05-EC105RD4046.452 2 8FT MULTI-DECK ISLAND CENTER (TOP FED)HUSSMANN CORPORATIONIM-05-EC105RD4047.452 2 6FT MULTI-DECK ISLAND END (TOP FED)HUSSMANN CORPORATIONIM-05-EC105RD9009.005 1 8FT SINGLE DECK ISLANDSTRUCTURAL CONCEPTS CORP MIR5RH0122.000 1 4FT SELF-SERVICECUSTOM DELIS EQUIPMENT CO INC DILW-SS5,7RH0135.000 1 8FT SERVICE SELF-SERVICECUSTOM DELIS EQUIPMENT CO INC ILW-CB-SS5SERVICE DELI EQUIPMENT LEGENDWDS NUMBER QTY.DESCRIPTIOND007A3 MOBILE STANDD007B3 SLICERD1021 BLAST CHILLER•••901 SERVICE DELI, 902 DELI PREP & 906 BAKERYNOTE: IF ANY SCOPE ITEMS BELOW ARE EXISTING, CONTRACTOR TO OMIT ADDED SCOPE OF WORK.WALLSETR.FLOORETR.CEILINGREF CEILING SCHEDULE.WEDGE EQUIPMENT LEGENDNO. QTYDESCRIPTIONMFR OR SUPPLIER MODEL NO.W507 1 36" PREBUILT WEDGE ASSEMBLYQUALSERV SOLUTIONSLLCWMWG36STW506 1 46" PREBUILT WEDGE ASSEMBLYQUALSERV SOLUTIONSLLCWMWG46ST 3/4" = 1'-0"2WEDGE KITGENERAL WEDGE NOTES:A. GC FURNISHED AND INSTALLED. GC TO ORDER KIT FROM QUALSERV, SEE CONTACT BELOW.B. SIDE SCRIBE PIECES PROVIDED WITH WEDGE. FIELD CUT TO FIT.C. WEDGE TOP PIECE PROVIDED WITH WEDGE. FIELD CUT TO FIT.GROCERY DRY WEDGE KIT CONTACT: QUALSERV(479) 646-8386 x-310 ATTN: DION CHAMBERS