2020.0103.BPP0008 0190 - GA3 GROCERY DETAILS - 3705PROVIDE 3/8" HEX HEAD BOLT, 1-1/4" FENDER WASHER, LOCK WASHER AND NUT, TYPPROVIDE UNISTRUT.LENGTH AS REQUIRED TO SPANJOISTS. SECURE TO BOTTOM CHORDOF BAR JOISTBAR JOIST,TYPBOTTOM CHORD OF BAR JOISTUNISTRUT(4) 3/8" ALL-THREAD RODS (2 PER UNISTRUT) TO SUPPORT PVC CHASEPVC SDR 35 VAN STONE FLANGE SOLVENT WELDED AND BOLTED TO PIPE. MAX 12" BELOW JOISTS.PVC SDR 35 VAN STONE FLANGE SOLVENT WELDED AND BOLTED TO PIPE(4) 3/8" ALL-THREAD RODS (2 PER UNISTRUT) TO SUPPORT PVC CHASEDOUBLE NUTW/WASHER TYPSDR-35 PVC CHASEWRAP WITH WHITE PVC JACKETNOTE:PVC CHASE TO BE CENTERED IN CHASE BETWEEN CASES UNLESS NOTED OR SHOWN OTHERWISE ON ARCHITECTURAL FLOOR PLANSGALVANIZED COLLAR WITH INTERNAL TABS. PAINT TO MATCH COLUMN JACKET. REF METAL PAINT SPECIFICATIONREFRIGERATED CASE CLOSURE PANEL/TOP OF REFRIGERATED CHASE SUPPLIED BY VENDORPROVIDE CONTINUOUS SEALANT AT PERIMETER JOINT. REF SEALANT SPECIFICATION.REFRIGERATED CASEREF REFRIGERATION PLANS FOR TYPE AND LOCATION3"CUT TABS 1" APART AND BEND INWARDPROVIDE 7" TALL GALVANIZED COLLAR WITH INTERNAL TABSREFER TO REFRIGERATION DRAWING FOR PIPE SUPPORTTHRU BOLT TYPUNISTRUT20 GAUGE SS ORALUMINUM FLASHING SET IN A CONT BED OF SEALANT. PROVIDE A 2" LAP WITH CONT BED OF SEALANT AT SPLICESPAN HEAD SHEETMETAL SCREWS AT 12"OCREFRIGERATED/HOT CASEFINISHED FLOOR2"MIN1"NOTE: INSTALL ALUMINUM FLASHINGBETWEEN CASE KICKPLATE ORCOUNTERFLASHING AND INTERNALFRAME. CASE AND CASE TRIM SHOWNHALFTONE FOR CLARITY.SERVICE SIDENOTE: DO NOT INSTALL FLASHING OVER DRAINS. IF DRAINS ARE PRESENT AT SERVICE SIDE OF CASE, START AND STOP FLASHING AT SIDES OF DRAIN. HEM EDGES OF FLASHING.architecture2809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209+engineeringArchitect of RecordWilliam Douglas HurleyWashington License No. 8855Unified Business ID No. 602 491 668STIPULATION FOR REUSETHIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DRAWN BY:CHECKED BY:DOCUMENT DATE:PROTO:SUPER BUNDLEPROTO CYCLE:DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTIONSHEET:ISSUE BLOCKYELM, WASHINGTON03/11/2020YELM, WASHINGTONSTORE NO.3705-232JOB NUMBER: 2019.0835ECJT17601/31/202003/11/2020GROCERYDETAILSGA3 12" = 1'-0"2PVC REFRIGERATION CHASE 3" = 1'-0"1CASE TRIM DETAIL AT SERVICE CASE