2020.0103.BPP0008 1010 - S1 PLAN GENERAL NOTES AND DETAILS - 3705 COPYfs 00 Or w ry al 75 J w Lo 0 r` M � a � U SAW -CUT EXISTING SLAB FULL DEPTH; APPLY BOND BREAK TO SLAB VERTICAL RESAW JT AND FILL WITH EDGE (AVOID APPLYING TO JOINT FILLER, REF 2B -S1 TOP OF EXISTING SLAB) EXISTING SLAB NEW SLAB GREASE END IN NEW SLAB; 1/2" DIAx10" SMOOTH DOWEL EMBED DOWEL 5" INTO AT 24" OC AND NOT MORE EXISTING SLAB WITH ADHESIVE THAN 12" FROM A CORNER ANCHOR (REF SPECS) NOTE: IF EXISTING SLAB IS LESS THAN 3 1/2" THICK, NOTIFY OWNER'S REPRESENTATIVE. C� z w w �U o �w 75 6C - CONSTRUCTION JOINT AT EXISTING SLAB FILL JOINT FLUSH WITH 1/8" ADJACENT FLOOR SURFACE RESAW CONSTRUCTION JOINT 1/8" x T/4 DEEP TO PRODUCE VERTICAL SIDE WALL AND HORIZONTAL SHELF TO SUPPORT JOINT FILLER. FILL WITH JOINT FILLER OR JOINT SUBFLOOR FILLER WHERE REQUIRED PER SPECIFICATIONS NOTE: DOWELS MUST BE LEVEL AND SQUARE WITH JOINT. DOWEL AT 24" OC, REF SPECS _x 613 - NEW CONSTRUCTION JOINT (CONST JOINT) FILL JOINT FLUSH WITH ADJACENT FLOOR SURFACE SAWCUT CJ, FILL WITH JOINT FILLER OR JOINT SUBFLOOR FILLER WHERE REQUIRED PER SPECIFICATIONS 1/8" x T/4 DEEP SAWCUTCONTRACTION JOINT FOR WET CUTTING OR EARLY ENTRY SAW CUTTING J I/ 6A - NEW CONTRACTION JOINT (CJ) SLAB REPLACEME J % 3/4" = 1'-0" NOTE: REF ARCH/MECH FOR EXACT LOCATIONS OF ROOF PENETRATIONS. FIELD VERIFY _ CL OF EXISTING JOIST I I I - I LL I B I I w_ w_ I LL > w > TYP N �4516i �! 1 1'\-\RSPECIFICATIONS MIX, TESTING,ING, CARE, ETC \ /\ EXISTING SLAB TO REMAIN G`�Q (2) #4x2'-0"; SET 1 1/2" FROM DESIGN LOADS GENERIC SLAB PLAN ENTRANT COR�E- r en nTlnl� nl nn T� I' -AlKi _IVIF111V :EF SPECIFICATIONS OR MIX, TESTING, TURING, CARE, ETC ". .� _AB TO REMAIN GENERIC SLAB PLAN SLAB REPLACEMENT NOTES: 1. SAW CUT EXISTING SLAB FULL DEPTH AT PERIMETER OF SLAB SECTION TO BE REPLACED. 2. EMBED SMOOTH DOWELS 5" INTO EXISTING CONCRETE SLAB, REFERENCE ADJACENT DETAILS. GREASE END IN NEW SLAB. USE TORPEDO LEVEL AND CARPENTER'S SQUARE TO ENSURE DOWELS ARE ALIGNED LEVEL AND PERPENDICULAR TO EXISTING SLAB EDGE. 3. AVOID SPALLING EDGES OF JOINTS WHEN RESAWING AFTER CONCRETE PLACEMENT. DAMAGED (SPALLED) CONCRETE SHALL BE REMOVED TO THE NEXT ALLOWABLE INCREMENT AND REPLACED AT THE CONTRACTOR'S EXPENSE, WITH NO EXTENSION OF THE CONSTRUCTION SCHEDULE. 4. REF GENERAL NOTES FOR COMPACTION REQUIREMENTS FOR SUBGRADE AND BASE, IF REQUIRED. SURFACE OF SUBGRADE AND BASE, IF REQUIRED, AFTER COMPACTION SHALL BE DRY, SMOOTH, FLAT AND DENSE. 5. IF EXISTING SLAB HAS A CONTINUOUS VAPOR BARRIER OR IF NEW SLAB IS TO RECEIVE EPDXY RESIN TOP COAT, INSTALL VAPOR BARRIER UNDER SLAB BEING REPLACED. TURN BARRIER UP AT FACE OF EXISTING CONCRETE TO REMAIN AND ATTACH USING FULL SEALANT BED PRIOR TO PLACING CONCRETE. 6. PRE -SLAB INSTALLATION MEETING MAY BE REQUIRED PRIOR TO FIRST CONCRETE SLAB PLACEMENT. REF SPECS FOR REQUIREMENTS. 7. REPLACEMENT SLAB CONTRACTION JOINT, REF SLAB PLANS FOR LOCATIONS. REPLACE CONCRETE TO MATCH ADJACENT FINISH, JOINTS AND DETAILING, REF SPECS. REF SPECS FOR CURING INFORMATION. 8. INSTALL DOWELS AT CONSTRUCTION JOINTS BETWEEN ADJACENT NEW REPLACEMENT SLABS AS REQD, REF 6B -S1, DOWELS NOT REQUIRED AT CONTRACTION JOINTS.DV NT DETAILS - 4" REINFORCED SLAB NON-STRUCTURAL ROOFCURB 3.0-2A NOTE: ANGLE SUPPORT FRAMING IS REQUIRED AT ALL EXHAUST FANS AND ROOF DRAIN PENETRATIONS, REGARDLESS OF SIZE. ATTACH CURB AND METAL DECK TO NO ANGLE WITH #12 TEK RO SCREWS AT 6" OC EXISTING ROOF DECK --- -- I EXISTING JOIST CL OF L5x3x1/4 (LLH), TYP TOP CHORD rvin PLAN VIEW OPENING IN >TING JOIST CL OFJOIST 3/16 3 1/8 1 /16 1/8 1 TYP SECTION A ROOF LARGER THAN 10"x10" 1:6 TOP CHORD PANEL 3" OR GREATEF CONCENTRATED LOAD, REF NOTE / 1/8 1 TYP EACH 1/8 1 < END EACH ANGLE NOTE: PROVIDE JOIST REINF IN ACCORDANCE WITH THIS DETAIL FOR ALL CONCENTRATED LOADS IN EXCESS OF 100 LBS. WHERE MORE THAN ONE CONCENTRATED LOAD EXISTS WITHIN A CHORD PANEL AND THE SUM OF THOSE LOADS EXCEEDS 100 LBS, PROVIDE JOIST REINFORCEMENT AS DETAILED SUCH THAT THE SUM OF THE LOADS WITHIN THE REMAINING UNSUPPORTED CHORD LENGTH DOES NOT EXCEED 100 LBS. RE-ENTRANT CORNER AND A. WIND LOADS 1. 1. BUILDING CODE 1. DO NOT RUN RE-ENTRANT PLACED 1 1/2" BELOW TOP CRITERIA. SLEEVE SIZES AND LOCATIONS. - ULTIMATE DESIGN WIND SPEED CORNER REINF STEEL OF SLAB, TYP TOP - BASIC DESIGN WIND SPEED (SERVICE) 3. THROUGH CONTRACTION 2. WIND EXPOSURE CATEGORY FOUNDATIONS OR SLABS TO REMAIN. EXISTING SLAB TO REMAIN JOINTS (CJ), TYP 0� } UNLESS NOTED OTHERWISE, GC MAY CORE DRILL 2. GRAVITY LOADS B. SEISMIC LOADS (SERVICE) U MUST BE APPROVED BY THE OWNER'S CONSTRUCTION A. ROOF LIVE LOADS 5% DAMPED MAPPED ACCELERATION PARAMETER (Se) MANAGER. FIELD VERIFY LOCATION OF EXISTING CJ. SHALL BE REPLACED WITH CONCRETE MATCHING 2. CJ EXISTING. B. GROUND SNOW LOAD (Pg) NOTE: 21 CJ 5% DAMPED SPECTRAL RESPONSE COEFF (Sds) U 8. NO REINF STEEL NECESSARY LONGITUDINAL SLAB REINFORCING AT 12" OC PLACED 3. LATERAL LOADS ACTIVITY THAT GENERATES SPARKS OR INTENSE HEAT. 2" BELOW TOP OF SLAB. STOP #4 LONGITUDINAL U GENERIC SLAB PLAN ENTRANT COR�E- r en nTlnl� nl nn T� I' -AlKi _IVIF111V :EF SPECIFICATIONS OR MIX, TESTING, TURING, CARE, ETC ". .� _AB TO REMAIN GENERIC SLAB PLAN SLAB REPLACEMENT NOTES: 1. SAW CUT EXISTING SLAB FULL DEPTH AT PERIMETER OF SLAB SECTION TO BE REPLACED. 2. EMBED SMOOTH DOWELS 5" INTO EXISTING CONCRETE SLAB, REFERENCE ADJACENT DETAILS. GREASE END IN NEW SLAB. USE TORPEDO LEVEL AND CARPENTER'S SQUARE TO ENSURE DOWELS ARE ALIGNED LEVEL AND PERPENDICULAR TO EXISTING SLAB EDGE. 3. AVOID SPALLING EDGES OF JOINTS WHEN RESAWING AFTER CONCRETE PLACEMENT. DAMAGED (SPALLED) CONCRETE SHALL BE REMOVED TO THE NEXT ALLOWABLE INCREMENT AND REPLACED AT THE CONTRACTOR'S EXPENSE, WITH NO EXTENSION OF THE CONSTRUCTION SCHEDULE. 4. REF GENERAL NOTES FOR COMPACTION REQUIREMENTS FOR SUBGRADE AND BASE, IF REQUIRED. SURFACE OF SUBGRADE AND BASE, IF REQUIRED, AFTER COMPACTION SHALL BE DRY, SMOOTH, FLAT AND DENSE. 5. IF EXISTING SLAB HAS A CONTINUOUS VAPOR BARRIER OR IF NEW SLAB IS TO RECEIVE EPDXY RESIN TOP COAT, INSTALL VAPOR BARRIER UNDER SLAB BEING REPLACED. TURN BARRIER UP AT FACE OF EXISTING CONCRETE TO REMAIN AND ATTACH USING FULL SEALANT BED PRIOR TO PLACING CONCRETE. 6. PRE -SLAB INSTALLATION MEETING MAY BE REQUIRED PRIOR TO FIRST CONCRETE SLAB PLACEMENT. REF SPECS FOR REQUIREMENTS. 7. REPLACEMENT SLAB CONTRACTION JOINT, REF SLAB PLANS FOR LOCATIONS. REPLACE CONCRETE TO MATCH ADJACENT FINISH, JOINTS AND DETAILING, REF SPECS. REF SPECS FOR CURING INFORMATION. 8. INSTALL DOWELS AT CONSTRUCTION JOINTS BETWEEN ADJACENT NEW REPLACEMENT SLABS AS REQD, REF 6B -S1, DOWELS NOT REQUIRED AT CONTRACTION JOINTS.DV NT DETAILS - 4" REINFORCED SLAB NON-STRUCTURAL ROOFCURB 3.0-2A NOTE: ANGLE SUPPORT FRAMING IS REQUIRED AT ALL EXHAUST FANS AND ROOF DRAIN PENETRATIONS, REGARDLESS OF SIZE. ATTACH CURB AND METAL DECK TO NO ANGLE WITH #12 TEK RO SCREWS AT 6" OC EXISTING ROOF DECK --- -- I EXISTING JOIST CL OF L5x3x1/4 (LLH), TYP TOP CHORD rvin PLAN VIEW OPENING IN >TING JOIST CL OFJOIST 3/16 3 1/8 1 /16 1/8 1 TYP SECTION A ROOF LARGER THAN 10"x10" 1:6 TOP CHORD PANEL 3" OR GREATEF CONCENTRATED LOAD, REF NOTE / 1/8 1 TYP EACH 1/8 1 < END EACH ANGLE NOTE: PROVIDE JOIST REINF IN ACCORDANCE WITH THIS DETAIL FOR ALL CONCENTRATED LOADS IN EXCESS OF 100 LBS. WHERE MORE THAN ONE CONCENTRATED LOAD EXISTS WITHIN A CHORD PANEL AND THE SUM OF THOSE LOADS EXCEEDS 100 LBS, PROVIDE JOIST REINFORCEMENT AS DETAILED SUCH THAT THE SUM OF THE LOADS WITHIN THE REMAINING UNSUPPORTED CHORD LENGTH DOES NOT EXCEED 100 LBS. NFORCING 3.0-3 FOUNDATION A. WIND LOADS 1. REFER THIS SHEET FOR GENERAL NOTES AND DESIGN 6. 1. BASIC WIND SPEED (3 -SECOND GUST) CRITERIA. SLEEVE SIZES AND LOCATIONS. - ULTIMATE DESIGN WIND SPEED PROVIDE (2) #4x2'-0" PLACED 1 1/2" BELOW TOP OF SLAB TOP - BASIC DESIGN WIND SPEED (SERVICE) 3. DO NOT EXCAVATE UNDER ANY EXISTING 2. WIND EXPOSURE CATEGORY FOUNDATIONS OR SLABS TO REMAIN. TOP RISK CATEGORY UNLESS NOTED OTHERWISE, GC MAY CORE DRILL CJ B. SEISMIC LOADS (SERVICE) 16 MUST BE APPROVED BY THE OWNER'S CONSTRUCTION 1. 5% DAMPED MAPPED ACCELERATION PARAMETER (Se) MANAGER. FIELD VERIFY LOCATION OF EXISTING CJ. SHALL BE REPLACED WITH CONCRETE MATCHING 2. 1 -SEC PERIOD MAPPED ACCELERATION PARAMETER (S1) EXISTING. 5. NOTE: 21 3. 5% DAMPED SPECTRAL RESPONSE COEFF (Sds) U 8. NO REINF STEEL NECESSARY LONGITUDINAL SLAB REINFORCING AT 12" OC PLACED 16 ACTIVITY THAT GENERATES SPARKS OR INTENSE HEAT. 2" BELOW TOP OF SLAB. STOP #4 LONGITUDINAL 9. WHEN TWO CONTRACTION REINFORCING 6" SHORT OF CONTRACTION JOINTS. 4. 1 -SEC PERIOD SPECTRAL RESPONSE COEFF. (Sds1) 0.498g CONCRETE JOINTS TERMINATE AT RE- D 5. SITE CLASS II 2. ENTRANT CORNER. 1.0 6. RISK CATEGORY D 7. IMPORTANCE FACTOR (le) ■■ 8. SEISMIC DESIGN CATEGORY NFORCING 3.0-3 6.0-2 GENERAL CONTRACTOR TO PROVIDE AND INSTALL FIELD STRUT (L2x2x3/16) EACH SIDE OF JOIST AT ALL LOCATIONS WHERE CONCENTRATED LOAD DOES NOT OCCUR WITHIN 3" OF A PANEL POINT. INSTALL ANGLE WITH ONE END AT LOCATION OF LOAD AND OTHER END AT A PANEL POINT ON THE OPPOSITE CHORD, TYP. ANGLES SHALL BE INSTALLED PRIOR TO NEW LOAD BEING APPLIED TO THE JOIST JOIST TOP CHORD I I JOIST BOTTOM CHORD I u CONCENTRATED LOAD, REF NOTE 3" OR GREATER BOTTOM CHORD PANEL JOIST REINFORCING AT CONCENTRATED LOAD 3/4" = 1'-0" 5.0-2 SECTION B 37'- 8" GENERAL NOTES 2015 IBC WITH WASHINGTON AMENDMENTS FOUNDATION PLAN NOTES 1. REFER THIS SHEET FOR GENERAL NOTES AND DESIGN 6. REFER TO ARCHITECTURAL DRAWINGS FOR BOLLARD f'c = 3,500psi CRITERIA. SLEEVE SIZES AND LOCATIONS. 2. FINISH FLOOR EL = 100'-0" (MATCH EXISTING), UNO. 7. PROVIDE (2) #4x2'-0" PLACED 1 1/2" BELOW TOP OF SLAB TOP ONE WEEK FROM THE START OF CONSTRUCTION DATE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING MATERIAL, MEASUREMENTS, AND ELEVATIONS AND SHALL AT RE-ENTRANT CORNERS WITHOUT A CJ IN EACH 3. DO NOT EXCAVATE UNDER ANY EXISTING DIRECTION, REF 7-S1. TOP FOUNDATIONS OR SLABS TO REMAIN. TOP 3. 8. UNLESS NOTED OTHERWISE, GC MAY CORE DRILL 4. DEVIATIONS FROM CONST JOINT/CJ PATTERN SHOWN EXISTING SLAB AS REQUIRED TO REPLACE PLUMBING 16 MUST BE APPROVED BY THE OWNER'S CONSTRUCTION FIXTURES. REF ARCH AND MEP FOR LOCATIONS. SLAB 5. MANAGER. FIELD VERIFY LOCATION OF EXISTING CJ. SHALL BE REPLACED WITH CONCRETE MATCHING 6. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY SUPPORT AND MAINTAINING STABLITY OF EXISTING STRUCTURE DURING ALL PHASES OF CONSTRUCTION. EXISTING. 5. REF MECH DRAWINGS FOR DRAIN LOCATIONS AND 21 16 SLAB DEPRESSIONS AT DRAINS. 9. IN AREAS MARKED -o ► , PROVIDE #4 8. GENERAL CONTRACTOR SHALL PROVIDE FIRE PROTECTION FOR THE EXISTING STRUCTURE AND BUILDING CONTENTS DURING WELDING OR ANY OTHER CONSTRUCTION LONGITUDINAL SLAB REINFORCING AT 12" OC PLACED 16 ACTIVITY THAT GENERATES SPARKS OR INTENSE HEAT. 2" BELOW TOP OF SLAB. STOP #4 LONGITUDINAL 9. GENERAL CONTRACTOR SHALL COORDINATE THE SIZE AND LOCATION OF EQUIPMENT PADS AND PENETRATIONS THROUGH THE STRUCTURE FOR MECHANICAL, ELECTRICAL AND REINFORCING 6" SHORT OF CONTRACTION JOINTS. 6.0-2 GENERAL CONTRACTOR TO PROVIDE AND INSTALL FIELD STRUT (L2x2x3/16) EACH SIDE OF JOIST AT ALL LOCATIONS WHERE CONCENTRATED LOAD DOES NOT OCCUR WITHIN 3" OF A PANEL POINT. INSTALL ANGLE WITH ONE END AT LOCATION OF LOAD AND OTHER END AT A PANEL POINT ON THE OPPOSITE CHORD, TYP. ANGLES SHALL BE INSTALLED PRIOR TO NEW LOAD BEING APPLIED TO THE JOIST JOIST TOP CHORD I I JOIST BOTTOM CHORD I u CONCENTRATED LOAD, REF NOTE 3" OR GREATER BOTTOM CHORD PANEL JOIST REINFORCING AT CONCENTRATED LOAD 3/4" = 1'-0" 5.0-2 SECTION B 37'- 8" GENERAL NOTES 2015 IBC WITH WASHINGTON AMENDMENTS GENERAL CONCRETE LAP SPLICE (CLASS B) (IN) 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY TO COMPLETE THE WORK SHOWN OR IMPLIED BY THESE DRAWINGS. SHOP DRAWINGS SHALL BE SUBMITTED TO f'c = 3,000psi f'c = 3,500psi THE ARCHITECT AND ENGINEER FOR REVIEW AND APPROVAL PRIOR TO COMMENCING WORK. 20 PSF (MIN OR SNOW LOAD) 2. EXISTING CONDITIONS SHOWN MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. BIDDERS SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BID. WITHIN 25 PSF TOP ONE WEEK FROM THE START OF CONSTRUCTION DATE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING MATERIAL, MEASUREMENTS, AND ELEVATIONS AND SHALL TOP OTHER NOTIFY THE ARCHITECT, STRUCTURAL ENGINEER OF RECORD AND THE OWNER'S CONSTRUCTION MANAGER OF ANY DISCREPANCIES OR FORESEEN PROBLEMS. GENERAL OTHER TOP CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL FIELD MEASUREMENTS, EXISTING CONDITIONS, AND KNOWN COMPLICATIONS WITH THE MATERIAL SUPPLIERS. TOP 3. GENERAL CONTRACTOR SHALL CAREFULLY COORDINATE DEMOLITION AND NEW CONSTRUCTION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. 3 4. GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURES, UTILITIES, PROPERTY, ETC DURING CONSTRUCTION. RESTORE ALL ITEMS DAMAGED, AS REQUIRED BY 115 MPH 16 OWNER'S REPRESENTATIVE, TO THE OWNER'S SATISFACTION AT NO COST TO OWNER OR WITHOUT EXTENSION OF CONTRACT TIME. 90 MPH 5. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK SHALL BE SECURED TO PREVENT FALLING, LOOSENING OR CREATING DAMAGE OF ANY KIND IN THE FUTURE. C 6. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY SUPPORT AND MAINTAINING STABLITY OF EXISTING STRUCTURE DURING ALL PHASES OF CONSTRUCTION. II 7 BEFORE OR CONCURRENT WITH ANY EXCAVATIONS ADJACENT TO THE EXISTING BUILDING FOUNDATION OR SLAB, GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING 21 16 TEMPORARY SUPPORT FOR THE BASE AND SUBGRADE OF THE EXISTING SLAB AND FOUNDATIONS TO PREVENT UNDERMINING. 16 8. GENERAL CONTRACTOR SHALL PROVIDE FIRE PROTECTION FOR THE EXISTING STRUCTURE AND BUILDING CONTENTS DURING WELDING OR ANY OTHER CONSTRUCTION 124.8% 16 ACTIVITY THAT GENERATES SPARKS OR INTENSE HEAT. 49.7% 9. GENERAL CONTRACTOR SHALL COORDINATE THE SIZE AND LOCATION OF EQUIPMENT PADS AND PENETRATIONS THROUGH THE STRUCTURE FOR MECHANICAL, ELECTRICAL AND 0.833g 20 PLUMBING WORK. 0.498g CONCRETE SLABS -ON -GRADE D 1. SLABS -ON -GRADE ARE UNREINFORCED CONCRETE UNLESS NOTED OTHERWISE. II 2. PROVIDE SAW CUT JOINTS AT 12'-0" OC MAXIMUM SPACING UNLESS NOTED OTHERWISE ON THE CONTRACT DRAWINGS. 1.0 3. PROVIDE (2) #4x2'-0" BARS PLACED 1 1/2" BELOW TOP OF SLAB AND LOCATED DIAGONALLY AT REENTRANT CORNERS. D 4. "CJ" INDICATES SAW CUT CONTRACTION JOINT IN SLAB -ON -GRADE, "CONST JT" INDICATES DOWELED CONSTRUCTION JOINT IN SLAB -ON -GRADE. 26 CONCRETE AND REINFORCING STEEL STATEMENT OF SPECIAL INSPECTIONS SPECIAL INSPECTIONS ARE REQUIRED. REFER TO APPENDIX B OF THE PROJECT SPECIFICATIONS FOR THE FOLLOWING INFORMATION REGARDING THE REQUIREMENTS OF SPECIAL INSPECTIONS: 1. THE MATERIALS, SYSTEMS, COMPONENTS AND WORK REQUIRED TO HAVE SPECIAL INSPECTIONS. 2. THE TYPE AND EXTENT OF EACH SPECIAL INSPECTION. 3. THE TYPE AND EXTENT OF EACH TEST. 4. ADDITIONAL SPECIAL INSPECTION REQUIREMENTS FOR WIND OR SEISMIC RESISTANCE (WHEN APPLICABLE). 5. THE FREQUENCY OF SPECIAL INSPECTIONS AND TESTING. THE SPECIAL INSPECTION REQUIREMENTS ARE BASED ON CHAPTER 17 OF THE IBC. 41'-0" 1. MINIMUM COMPRESSIVE STRENGTH (f c) AT THE END OF 28 DAYS SHALL BE AS FOLLOWS: A. INTERIOR CAST -IN-PLACE CONCRETE SLABS 4000 PSI SPECIFICATION SECTION 03314 B. EXTERIOR CAST -IN-PLACE CONCRETE SLABS REF SPECS SPECIFICATION SECTION 03310 C. STRUCTURAL CAST -IN-PLACE CONCRETE FOOTINGS 3000 PSI SPECIFICATION SECTION 03310 D. STRUCTURAL FORMED CONCRETE WALLS REF SPECS SPECIFICATION SECTION 03310 E. CAST -IN-PLACE CONCRETE COMPACTOR PAD 5000 PSI SPECIFICATION SECTION 03310 FOR ALL OTHER CONCRETE PROPERTIES REFER TO SPECIFICATIONS. 2. CONCRETE FREEZING AND THAWING EXPOSURE CLASS SHALL BE F0. 3. REINFORCING STEEL SHALL MEET ASTM SPECIFICATION A 615, DEFORMED BAR, GRADE 60 OR ASTM SPECIFICATION A 706, DEFORMED BAR, GRADE 60. REF STEEL REINF LAP SCHEDULE FOR LAP LENGTHS, UNO ON DETAILS. 4. REFER TO ACI 315 FOR DETAILING PRACTICES AND FABRICATION, AND ACI 301 FOR STANDARD PRACTICE FOR MIXING AND PLACING CONCRETE AND CONCRETE COVER. 5. LEAN CONCRETE - MIN 2 1/2 SACKS PORTLAND CEMENT PER CUBIC YARD. STRUCTURAL STEEL 1. STRUCTURAL STEEL SHALL MEET THE FOLLOWING MINIMUM YIELD STRENGTH AND SPECIFICATIONS. FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE "AISC CODE OF STANDARD PRACTICE". STRUCTURAL STEEL YIELD ASTM SPECIFICATION A. PLATES, CHANNELS, ANGLES, & ANCHOR BOLTS: 36 KSI A 36, UNO B. ROUND BARS FOR JOIST REINFORCEMENT: 50 KSI A 529 C. WIDE FLANGE STEEL SHAPES: 50 KSI A 992 D. SQUARE AND RECTANGULAR HOLLOW STRUCTURAL SHAPES: 50 KSI A 500 GRADE C E. ROUND HOLLOW STRUCTURAL SHAPES: 46 KSI A 500 GRADE C F. HEADED STUD ANCHORS: 50 KSI A 108 (GRADE DESIGNATIONS 1010 TO 1020, INCLUSIVE) T 2. ALL STRUCTURAL STEEL SHALL HAVE ONE SHOP COAT OF RUST INHIBITOR PRIMER PAINT CONFORMING TO THE SPECIFICATIONS. REF SPECS FOR PROTECTIVE FINISH FOR EXTERIOR STEEL. FIELD TOUCH UP ALL UNPAINTED, NICKED AND WELDED AREAS. PAINT ALL STEEL EXPOSED TO VIEW TO MATCH EXISTING. 3. WELDING SHALL MEET ANSI/AWS D1.1 STRUCTURAL WELDING CODE. ELECTRODES SHALL BE 70 KSI LOW HYDROGEN. 4 PROVIDE 1 1/2 INCH NON SHRINK GROUT UNDER BASE PLATE AFTER ERECTION NON SHRINK GROUT WHERE INDICATED ON PLANS SHALL BE NON METALLIC WITH A MINIMUM TYP NOTE - r6 C OTE:6C THE EXISTING BUILDING SHALL BE S1 PROTECTED FROM MOISTURE, DUST, AND DEBRIS. INSTALL TEMPORARY DUST PARTITIONS AS REQUIRED TO PROHIBIT DUST EXISTING SLAB JOINTS TYP FROM ENTERING THE SALES AREA DURING DEMOLITION. 6A S1 TYP ,CLo: REF PLAN NOTE #7, TYP ;C REF PLAN NOTE #9, TYP 4" CONC SLAB (MATCH - EXISTING) UNREINF OVER EXISTING COMPACTED SUBGRADE, TYP; REF GENERAL NOTES. rn FOUNDATION PLAN / 1/8" = 1'-0" ATTACH CURB AND METAL DECK TO ANGLE WITH #12 TEK SCREWS AT 6" OC EXISTING ROOFDECK L5x3x1/4 (LLH), TYP EXISTING SLAB TO REMAIN, TYP STEEL REINF LAP SCHEDULE W � � J � � 0, ,OH �O �w } CONCRETE LAP SPLICE (CLASS B) (IN) CMU BAR SIZE f'c = 3,000psi f'c = 3,500psi f'c = 4,000psi f'c = 4,500psi f'c = 5,000psi LAP SPLICE Xw U N 2 d Fz0<oH0- }¢�w TOP OTHER TOP OTHER TOP OTHER TOP OTHER TOP OTHER (IN) 3 17 16 16 16 16 16 16 16 16 16 20 4 23 18 21 16 20 16 19 16 18 16 26 5 28 22 26 20 25 19 23 18 22 17 32 6 34 26 31 24 29 23 28 21 26 20 39 7 49 38 45 35 43 33 40 31 38 29 45 8 56 43 52 40 49 37 46 35 44 34 52 SECTION A CAPPED CURB, REF ARCH & MEP ATTACH CURB TO CHANNEL WITH #12 TEK SCREWS AT 12" OC, TYP 2 SIDES - C6x8.2 CONT INSTALLED OVER EXISTING ROOF DECK EXISTING MTL ROOF DECK TO REMAIN EXISTING TO REMA REMOTE CONDENSER ROOF CURB SU 3/4" = 1'-0" 5.0-1 SECTION B PPORT 1/8 1 TYP EACH 1/8 1 JOIST REF 3-S1 FOR JOIST REINFORCING AT CHANNEL LOCATIONS Q 2'-1" COMPRESSIVE STRENGTH OF 5,000 PSI AT 28 DAYS. 5. PROVIDE L5x3x1/4 (LLH) FIELD -FABRICATED FRAME BETWEEN JOISTS AT OPENINGS IN ROOF GREATER THAN 10"x10", UNO, (INCLUDING ROOF DRAIN AND EXHAUST FAN OPENINGS REGARDLESS OF OPENING SIZE). REF 4-S1. SUBGRADE AND BASE 1. PRIOR TO PLACEMENT OF SLABS IN SLAB REMOVAL AREAS, EXPOSED SUBGRADE SHALL BE COMPACTED TO AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D1557). WHERE SOILS ARE DISTURBED TO A DEPTH GREATER THAN 1'-0", COMPACTION SHALL BE PERFORMED IN A MAXIMUM 8 INCH LOOSE LIFTS. 2. IN SLAB REMOVAL AREAS WHERE SUBGRADE IS NEEDED TO RAISE PAD TO PROPER ELEVATION, PROVIDE BASE AND/OR CHOKER MATERIAL AS INDICATED IN SPECS. 3. NOTIFY IMMEDIATELY THE OWNER'S REPRESENTATIVE AND ENGINEER IF UNUSUAL SOIL CONDITIONS ARE FOUND. 41'-0" NEW RCU-1 (818 LBS MAX), REF 2-S1 FOR SUPPORT FRAMING REF 4-S1 FOR OPENING IN ROOF REF MECH =FER TO THIS SHEET FOR GENERAL NOTES AND =SIGN CRITERIA. )TE TO GENERAL CONTRACTOR: REFER TO SECT 120 OF THE CONTRACT SPECIFICATIONS FOR OW :OVIDED ITEMS. ALL OTHER STRUCTURAL AND SCELLANEOUS STEEL NOT PROVIDED UNDER :CTION 05120 SHALL BE PROVIDED BY THE GENEF )NTRACTOR AS NOTED IN SECTION 05500 OF THE 'ECIFICATIONS. IE DIMENSION LOCATING THE RCU'S IS APPROXIN CONTRACTOR TO LOCATE ALL RCU'S CURBS A- =AREST STEEL JOIST PANEL POINTS. IF CURB kNNOT BE LOCATED WITHIN 3" OF STEEL JOIST Pf )INT, REINFORCE STEEL JOIST PER DETAIL 3-S1. L EXISTING JOIST AND BEAM SIZES AND LOCATIO :E FROM ORIGINAL DRAWINGS AND SHALL BE FIE :RIFIED. ANY NEW MECHANICAL EQUIPMENT OR PIPING ,CEEDING 100 LBS NEEDS TO BE ATTACHED TO TI JSTING STRUCTURE, AND THOSE ITEMS ARE NOT ]OWN ON THESE DRAWINGS. THE CONTRACTOR ROOF FRAMING PLAN 1/8" = 1'-0" KAU I UK bMALL F'KUVIUt AUtZUUA I t NNtz NKU I t( - EXISTING STRUCTURE AND CONTENTS. AS A IUM: ✓LOVE COMBUSTIBLE MATERIALS FROM :AS OF WELDING AND SPARKS. )VIDE FIRE PROOF BLANKETS AND SHIELDS CONTAIN SPARKS WHERE COMBUSTIBLE FERIALS CANNOT BE REMOVED. )VIDE A FIRE SAFETY OBSERVER WITH A EXTINGUISHER ON BOTH THE ROOF AND 77 REF 4-S1 FOR OPENING IN ROOF REF MECH NEW RCU-2 (818 LBS MAX), REF 2-S1 FOR SUPPORT FRAMING - 2" 46'-8" �o ISSUE BLOCK CHECKED BY: DW/BF DRAWN BY: RB PROTO CYCLE: 01/31/2020 DOCUMENT DATE:03/11/2020 020.03.03 16:20:23-06'01 PLAN GENERAL NOTES AND DETAILS SHEET: S1 W � � J � � 0, ,OH �O �w } cn O zWU dZU'�Q D W UOui2ZOFDzu>1 u xz W �0, W 1<0o ¢H ~ W�W00o�w0 0< L ¢ W w�W J0anw <Z 0O ,w ¢Z¢ O Xw U N 2 d Fz0<oH0- }¢�w z ¢VOONw ¢ ~UHC Ow�0=OzNGo=OzN=Z�- O� n!2 Ooa za-Ix0-<s~¢ 0- Ir¢ 2i Z J U, w w w O O Kof Z wOMW-a�cnOwO¢ 00� H W¢,=2 D Z c[u>=J u�w�z�LO,¢owan�w (1) r�>OUondOw�J��¢� ISSUE BLOCK CHECKED BY: DW/BF DRAWN BY: RB PROTO CYCLE: 01/31/2020 DOCUMENT DATE:03/11/2020 020.03.03 16:20:23-06'01 PLAN GENERAL NOTES AND DETAILS SHEET: S1 Z Lu J 0 z %0 0 m Lu � O O I- w co n!2 v % N C'' N O Z Lo C) 0H a. M 0G�gZ 00 co00 Z W cl� o Oi o O H N 0 U) 5^ J W w m z z m O ISSUE BLOCK CHECKED BY: DW/BF DRAWN BY: RB PROTO CYCLE: 01/31/2020 DOCUMENT DATE:03/11/2020 020.03.03 16:20:23-06'01 PLAN GENERAL NOTES AND DETAILS SHEET: S1