Loading...
2020.0103.BPP0008 3020 - P1 ENLARGED PLUMBING PLANS - 3705S LICERWRAP PERS CA LES INKTA BLETA BLETA BLE RH0135.000RD4043.042RD4043.042RH0122.000RD4043.042PIZZAPANS12"x48"KNEE KNOCKER12"x48"KNEE KNOCKER12"x48"KNEE KNOCKER12"x48"KNEE KNOCKER12"x48"KNEE KNOCKER12"x48"KNEE KNOCKERREFRIGERATORFD3FD3FD3FD3FCO13" VTR4" SSFCO ETR15.4034" SS4"SS ETR1P22P23P2FCO1TYPTYP3" SS TYPSS006LRHSETRFCOETRFD ETR4" ETR3"15.403L20L18L20L18PROVIDE BRANCH WASTE AND VENT PIPING IN WALL AS REQUIRED FOR INDIVIDUAL P-TRAPS AT EACH BASIN. TYP1' - 0"1' - 0"2' - 3"2' - 3"FD3FD3FD3FD3FCO1FCO13" VTRFCO ETRREMOVE EXISTING FLOOR DRAIN, PLUG P-TRAP, AND REPLACE WITH A SOLID, GAS TIGHT COVER.3' - 0"1' - 0"3' - 0"1' - 0"FD ETRSS006LRHS ETRFCO ETR15.40315.4042"V ETR4" ETRL16L16PROVIDE BRANCH WASTE AND VENT PIPING IN WALL AS REQUIRED FOR INDIVIDUAL P-TRAPS AT EACH BASIN. TYParchitecture2809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209+engineeringEngineer of RecordJoshua Dale McCall, P.E.Michigan License No. 6201063368SHEET:DRAWN BY:CHECKED BY:PROTO CYCLE:DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTIONEXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS.EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.PROTO:173P1ENLARGEDPLUMBINGPLANSRANYELM, WASHINGTON2019.0835YELM, WASHINGTON03/11/202003/11/2020STORE NO: 3705-232SUP12-20-19JDMKEYNOTES15.403 CONNECT TO EXISTING SANITARY PIPE OFEQUAL OR LARGER SIZE. VERIFY SIZE,LOCATION, ELEVATION, AND FLOW DIRECTION ATSITE.15.404 CONNECT TO EXISTING VENT PIPE OF EQUAL ORLARGER SIZE. VERIFY SIZE AND LOCATION ATSITE.REFER TO SHEET MP1 FOR GENERAL NOTES PERTAINING TO THIS SHEET.GENERAL NOTES5REAR GROCERY DWV RISER 1/8" = 1'-0" 1FRONT GROCERY PLUMBING PLAN 1/8" = 1'-0" 2REAR OFFICE PLUMBING PLAN 1/8" = 1'-0" 3REAR GROCERY PLUMBING PLANISSUE BLOCK4FRONT GROCERY DWV RISER 1/8" = 1'-0" 6FRONT RESTROOM PLUMBING PLAN