2020.0103.BPP0008 3720 - R2 REFRIGERATION PLANS - 3705 COPY4 10 NEW RCU-1 MOUNTED ON—"" N R4 ROOF. REFER TO 15.610 STRUCTURAL DRAWINGS FOR MOUNTING DETAILS — — - H - < OHM OHMHM 11' 15.625 15.611 15.609 15.609 MTE-9 RU-1 24'-05DM-NRG 14'-I -05-EC (RELOCATE) (NEW) 7FINEW PIPE CHASE IN ROOF. COORDINATE 4 SIZE AND LOCATIONER, WITH STRUCTURE (TYP) = \-REFRIGERATION 6 PIPING DOWN THROUGH ROOF. R4 (TYP) 15.603 15.618 2 5 15.612 15.603 R4 R4 —RUN LINES IN BASE OF CASE (T' 9 R4 115.609 15.609 C) RCU-1 CU -1 7 END -IM -05 -EC 14' -IM -05 -EC R4 I (NEW) ( EW) E 15.612 8 15.603 R4 Eg 0 m 15.619 15.609 RCU-1 ND -IM -05 -EC /Alr%Al\ 2 0 0 0 0 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I REAR REFRIGERATION PLAN 1/8" = 1'-0" Q PIPING SCHEDULE RACK MTE PIPE DESIGNATION PIPE DESIGNATION I VERTICAL SUCTION RISER AS REQUIRED LIQUID ESTIMATED TOTAL LENGTH** ESTIMATED TOTAL LENGTH** E1 13/8**** 1/2 11/8**** 7/8**** 0 0 0 0 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I REAR REFRIGERATION PLAN 1/8" = 1'-0" Q EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. LU PIPING SCHEDULE RACK MTE PIPE DESIGNATION PIPE DESIGNATION HORIZONTAL SUCTION VERTICAL SUCTION RISER AS REQUIRED LIQUID ESTIMATED TOTAL LENGTH** ESTIMATED TOTAL LENGTH** E1 13/8**** 1/2 11/8**** 7/8**** F2 75 E2 13/8 J 1 1/8 5/8 11/8 165 E3 13/8 80 1 1/8 5/8 - 165 E4 13/8 F5 11/8 5/8 5/8 110 E5 21/8 7/8 1 5/8 7/8 N 145 E5A 13/8 7/8 1 1/8 5/8 105 25 E56 13/8 5/8 1 1/8 5/8 F9 25 E6 15/8 1 3/8 7/8 1 5/8 95 E7 7/8 85 5/8 1/2 13/8 80 E8 11/8 F12 7/8 1/2 1/2 80 E8A 5/8 7/8 1/2 1/2 35 E8.1 5/8 1/2 1/2 60 E8B 7/8 7/8 1/2 35 E8C 5/8 1/2 1/2 35 E9 1 1/8**** 7/8**** 5/8**** 100 * RISER SIZE IS SHOWN EVEN WHERE A RISER IS NOT EXPECTED. THIS IS FOR REFERENCE ONLY AND TO BE USED IN THE EVENT THAT A PIPING CONFLICT CAUSES THE NEED FOR A RISER. IF RISER LENGTH EXCEEDS 4 FEET, IT MUST BE APPROVED BY ENGINEER OF RECORD. **ESTIMATED TOTAL LENGTH INCLUDES HORIZONTAL AND VERTICAL PIPE SECTIONS. THIS IS ONLY AN ESTIMATE AND ACTUAL LENGTH WILL VARY. ****NEW PIPING EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. LU PIPING SCHEDULE RACK MTF FjOO af (wj M Z(7Z PIPE DESIGNATION HORIZONTAL SUCTION VERTICAL SUCTION RISER AS REQUIRED LIQUID 0 ESTIMATED TOTAL LENGTH** Fl 7/8 5/8 1/2 F_ 100 F2 7/8 5/8 1/2 J 70 F3 11/8 7/8 1/2 O 80 F4 7/8 - 1/2 0 � STUB F5 11/8 - 5/8 Lu STUB F6 7/8 5/8 1/2 N 130 F7 1 1/8 7/8 5/8 105 F8 1 1/8 7/8 5/8 m O 145 F9 11/8 7/8 5/8 110 F10 1 5/8 13/8 7/8 1 85 F11 15/8 13/8 7/8 60 F12 1 1/8 7/8 1/2 60 F13 7/8 1/2 1/2 140 * RISER SIZE IS SHOWN EVEN WHERE A RISER IS NOT EXPECTED. THIS IS FOR REFERENCE ONLY AND TO BE USED IN THE EVENT THAT A PIPING CONFLICT CAUSES THE NEED FOR A RISER. IF RISER LENGTH EXCEEDS 4 FEET, IT MUST BE APPROVED BY ENGINEER OF RECORD. **ESTIMATED TOTAL LENGTH INCLUDES HORIZONTAL AND VERTICAL PIPE SECTIONS. THIS IS ONLY AN ESTIMATE AND ACTUAL LENGTH WILL VARY. ****NEW PIPING EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. LU 0 F- 0 WWa0FIX DRAWN BY: FjOO af (wj M Z(7Z W W ~ z w W d Z� F Z w CE LL QF LLWLLOOO Wo 0 _< ��o WW�zo-w ifw ro¢gxofw¢cnafm LL (�z Z) 1:>o�wa 0 Wgo=oo WF -0=0 F_ -)oZNDO?ZWxZFz zm=ofg � zmwp¢W a 0z oM(Fj1_jWwowit oo�WW¢W=2Dzwu)m J �WJ ZFFOF¢ OW d7FW OUou=im0wly�OfOf<r o M r�w %0z 0 DRAWN BY: ED_ O Z PROTO CYCLE: N 00 W o a I W Zo.=� z O N Z � c ? c" Z y 3 J Ll m 0 0 o M 13 Z U) Q O U %0z KK DRAWN BY: w J 0 m O 7 L PROTO CYCLE: w a 00 O V N M � z � = o M U) Q O Lu 0 � 0 (n Lo M 00 o J Lu rn 0 ` r N w m z m O ISSUE BLOCK CHECKED BY: KK DRAWN BY: AG P ROTO: 176 PROTO CYCLE: 013120 DOCUMENT DATE: 03/11/2020 03/11/2020 DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTION REFRIGERATION PLANS SHEET: R2