2020.0103.BPP0008 4010 - E1 LIGHTING PLAN - 3705E1.15EXISTING LIGHTING FIXTURES NOT SHOWN ARE EXISTING TO REMAIN AND ARE NOT AFFECTED BY THE SCOPE OF WORK ON THIS PROJECT. THIS INCLUDES ALL GENERAL LIGHTING, EGRESS LIGHTING, AND EXIT LIGHTING.PROVIDE LISTED HANDLE-TIE BETWEEN CIRCUIT BREAKERS SHARING COMMON NEUTRAL FOR SIMULTANEOUS TRIP. TYP OF ALL CIRCUITS SHOWN ON ALL ELECTRICAL SHEETS.ADJUST AIMING OF EMERGENCY LIGHT LAMP HEADS AS REQUIRED TO PROVIDE PROPER ILLUMINATION AT FLOOR, AVOIDING OBSTACLES AND SHADOWS AFTER STORE SET-UP IS COMPLETE, TYP.STOCKROOMEMERGENCY LIGHTING AND EXIT SIGNAGE MUST BE CONNECTED TO THE UNSWITCH LINE SIDE OF THE LIGHTING CIRCUIT. TYP OF ALL CIRCUITS SHOWN ON ALL ELECTRICAL SHEETS.RECEIVINGEDC1CARTSTORAGE-GMVESTIBULE-GMSALESSMARTSTYLEDAIRYCOOLERGARDENCENTERREPLACE ALL BROKEN LIGHT FIXTURES ANDLENSES, TYP ENTIRE PHARMACY.1E1.1PHARMACYVISION CENTERCLAIMSEDC4SHADE CLOTHEXTEND EXISTING CIRCUITRY ASREQUIRED WHERE EXISTINGLIGHTING CIRCUITRY IS SHOWN TOBE INTERUPTED TO ADD NIGHTLIGHTING IN THE GLAZED CANOPYAND SHADE CLOTH CANOPY AREA.E1.13E1.18E1.12E1.17JANITORABCDEFGHIJ12345678910111213EDC2MANAGERVESTIBULE-GRCARTSTORAGE-GRENTRY-GRENTRY-GMBLIMPIE'S16.131H2P-41#10WTYP16.12516.125TYP16.12516.125TYP16.125EXISTING SHADE CLOTHLIGHT FIXTURES TO BEREPURPOSED AS NIGHTLIGHTS. TYP OF 3.16.12516.13316.13316.13316.13316.13316.133E1.14E1.1616.12516.131H1P1-202MOUNT TO THE BOTTOMSIDE OF RACK, TYP OF 2.BIKEASSEMBLYDESK16.13316.13316.13316.13316.13316.13316.133NLNLNLarchitecture2809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209+engineeringEngineer of RecordKeith Allen Williams, P.E.Washington License No. 43345SHEET:DRAWN BY:CHECKED BY:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTIONEXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. TYPICAL OF ALL ELECTRICAL SHEETS.EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. TYPICAL OF ALL ELECTRICAL SHEETS.DOCUMENT DATE:PROTO:PROTO CYCLE:17601-31-202003-11-2020E1LIGHTINGPLANBMSYELM, WASHINGTON2019.0835YELM, WASHINGTON03/11/2020STORE NO: 3705-232SUPKAWKEYNOTES16.125 EXISTING LIGHT FIXTURES TO REMAIN UNLESSNOTED OTHERWISE.16.131 CONNECT TO EXISTING CIRCUIT.16.133 EXISTING LIGHT FIXTURES TO BE RELOCATED TONEW LOCATION AS SHOWN. 1" = 20'-0" 1LIGHTING PLAN1.A.B.C.D.E.F.2.A.B.C.D.E.3.4.5.6.EXIT SIGN MOUNTINGWALL FIXTURE: CENTER 12" ABOVE DOOR OPENING.CEILING FIXTURE: ON CEILING OR AT HEIGHT SPECIFIED ON DRAWINGS.PENDANT FIXTURE: MATCH HEIGHT OF EXISTING PENDANT MOUNTED EXIT SIGNS. IF STORE DOES NOT HAVE PENDANT MOUNTED EXIT SIGNS, THEN PENDANT MOUNT SIGN 24" BELOW BOTTOM OF BAR JOIST. VERIFY MOUNTING HEIGHT WITH AHJ.COORDINATE LOCATIONS OF EXIT SIGNS TO ENSURE STORE SIGNAGE DOES NOT OBSTRUCT THEIR VIEW.THE USE OF TRITIUM BASED RADIOACTIVE EXIT SIGNAGE IS PROHIBITED.EMERGENCY LIGHT FIXTURE INSTALLATION WALL FIXTURE: 12" BELOW FINISHED CEILING OR +10'-0" IN AREAS OF EXPOSED STRUCTURE, UNLESS NOTED OTHERWISE.PENDANT FIXTURE: BOTTOM CHORD OF BAR JOIST OR AT HEIGHT SPECIFIED ON DRAWINGS.REMOTE HEAD FIXTURE: HEADS CENTERED ABOVE DOOR OPENING +9'-0", UNLESS NOTED OTHERWISE AND BATTERY PACK MOUNTED ON INTERIOR SIDE OF WALL 12" BELOW FINISHED CEILING OR AT BAR JOIST IN AREAS OF EXPOSED STRUCTURE.REFER TO MANUFACTURER'S WRITTEN INSTRUCTIONS. ALLOW BATTERY TO CHARGE CONTINUOUSLY FOR A MINIMUM OF 24 HOURS BEFORE INITIAL TESTING.AFTER EMERGENCY LIGHT HAS BEEN POWERED DO NOT TURN OFF FOR EXTENDED PERIODS OF TIME.EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT LIGHTS SHALL NOT BE SWITCHED.IN AREAS OF OPEN STRUCTURE, MOUNT STRIP FIXTURE TO BOTTOM CHORD OF BAR JOIST, UNLESS NOTED OTHERWISE.PROVIDE SEPARATE BOXES FOR GANGED SWITCHES ON SEPARATE BRANCH CIRCUITS.FIXTURES DENOTED WITH "ABJ" ARE TO BE FASTENED ON UNISTRUT CHANNELS MOUNTED TO THE BOTTOM SIDE OF THE TOP CHORD OF BAR JOISTS. LOCATE THE FIXTURES RUNNING PERPENDICULAR TO BAR JOISTS WITHIN BAR JOISTS WEBBING SPACES. DO NOT FASTEN FIXTURE OR UNISTRUT CHANNELS TO ROOF DECK.GENERAL LIGHTING NOTES01.31.201.2.3.4.5.6.7.OCCUPANCY SENSORS IN RESTROOMS SHALL BE PROGRAMMED FOR AUTOMATIC ON AND MAXIMUM AVAILABLE TIME DELAY SETTINGS.OCCUPANCY SENSORS IN DELI, PRODUCE, AND BAKERY PREP AREAS SHALL BE PROGRAMMED WITH MAXIMUM AVAILABLE TIME DELAY SETTINGS.OCCUPANCY SENSORS IN WALK-IN COOLERS/FREEZERS SHALL BE LOW TEMPERATURE RATED, WALL MOUNTED 6" ABOVE DOOR. ADJUST AIMING FOR MAXIMUM COVERAGE, 10 MINUTE TIME DELAY.ALL OTHER OCCUPANCY SENSORS SHALL BE PROGRAMMED WITH THE MINIMUM AVAILABLE TIME DELAY SETTING UNLESS NOTED OTHERWISE.ALL SINGLE-POLE OCCUPANCY SENSORS SHALL BE PROGRAMMED FOR MANUAL ON LIGHTING CONTROL UNLESS NOTED OTHERWISE.ALL BI-LEVEL OCCUPANCY SENSORS SHALL BE PROGRAMMED FOR AUTOMATIC ON LIGHTING CONTROL FOR 50% OF FIXTURES AND WITH MANUAL ON MODE FOR REMAINING FIXTURES.WHERE TWO OCCUPANCY SENSORS ARE SHOWN IN THE SAME LOCATION WIRE FOR PARALLEL OPERATION.OCCUPANCY SENSOR NOTES01.31.20ISSUE BLOCK