2020.0103.BPP0008 4060 - E3 ELECTRICAL DETAILS - 37052-1/2" PVC CONDUITEXTENDER ARM /POWER POLEPROVIDE 2-1/2" UNISTRUT STRAP TO FIRMLY CLAMP TO CONDUITINSTALL TWO-PIECE, SELF-ADHESIVE FLANGE FURNISHED WITH POLE WHEREVER POLE PASSES THROUGH MILLWORK, EXCEPT AT CHECKOUTSFINISHED FLOORPROVIDE UNISTRUT P1026 ANGLE FITTING OR EQUALUNISTRUTPROVIDE 1/4" BOLT AND 1-1/4" FENDER WASHER, TYPPROVIDE 1-1/4" FENDER WASHER, LOCK WASHER AND NUT, TYPPROVIDE UNISTRUT PER SPECIFICATIONS. LENGTH AS REQUIRED TO SPAN JOISTS. SECURE TO BOTTOM CHORD OF BAR JOIST.BOTTOM CHORD OF BAR JOISTNO CONNECTION OF ANY KIND SHALL BE MADE TO JOIST WEB MEMBERS, JOIST BRIDGING, OR ROOF DECK. MAINTAIN MINIMUM 6" CLEARANCE FROM TOP OF POWER POLE TO ROOF DECK. JUNCTION BOXES AND RACEWAYS SHALL NOT BE MOUNTED WITHIN 1-1/2" OF DECK.INSTALL FURNISHED POWER POLE. MOUNT JUNCTION BOX(ES) TO TOP SIDE OF BOTTOM CHORD OF BAR JOIST. PROVIDE 3/8" FLEXIBLE METAL WHIPS FROM JUNCTION BOX AND CONNECT AT TOP OF POWER POLE. CABLE WHIPS TO POWER POLE SHALL BE INSTALLED IN A NEAT AND WORKMAN-LIKE MANNER. ROUTE WHIPS TO TERMINATIONS ALONG UNISTRUT OR STRUCTURE AND SUPPORT EVERY 12" TO 24". EXCESS CABLE SHALL BE KEPT TO A MINIMUM AND TIGHTLY COILED AND ATTACHED TO UNISTRUT OR JOIST. EXTEND POWER POLE 12" MIN. WITHIN PVC SLEEVEINSTALL CEILING FLANGEFURNISHED WITH POLE WHEREVER POLE PASSES THROUGH CEILINGPROVIDE PVC SLEEVE LENGTH 12" MIN. TO 36" MAX. TO ACCOMMODATE VARIATIONS IN STRUCTURE HEIGHT.MILLWORKPOWER POLE FOOT (FOR FREESTANDING POLES)1/4" TAPCON+ AT 2-3/4" EMBEDMENT, TYPSPACER INCLUDED WITH FOOTPOWER POLEWHERE POWER POLE FOOT IS TO BE INSTALLED ON RUBBER FLOORING OR CARPET, REMOVE PORTION OF THE FLOORING TO ALLOW FOOT TO BE SECURED DIRECTLY TO THE FLOOR SLAB. REFER TO SPEC SECTION 05090. DO NOT INSTALL DIRECTLY ON TOP OF TRANSITION STRIPS. SECURING THE FOOT DIRECTLY ON TOP OF CERAMIC TILE, VCT FLOORING, PVC FLOORING, OR EXPOSED CONCRETE IS ACCEPTABLE.POLES ARE ABLE TO BE FIELD CUT FOR AREAS THAT HAVE LOWER STRUCTURE OR CEILINGS. FOLLOW MANUFACTURER INSTRUCTIONS FOR CUTTING. WHEN PENETRATING GYP BOARD CEILINGS OR SOFFITS COORDINATE LOCATION AND QUANTITY OF ACCESS PANELS TO MAINTAIN ACCESS PER NEC REQUIREMENTS WITH ARCHITECT. SECURE TOP OF POLE PER MANUFACTURER INSTRUCTIONS.WHEN INSTALLING ENTERTAINMENT TABLE (ENT) POWER POLE, A SEPARATE SPACER IS PROVIDED TO BE INSTALLED IN SPACE BETWEEN SIDE OF MILLORK AND POLE. ENSURE PROPER POLE ORIENTATION TO ALLOW POLE AND BRACKET TO BE MOUNTED FLUSH WITH THE TABLE.PROVIDE LOCKING SPRING NUTUNISTRUT SHALL SUPPORT NO MORE THAN 100LBS IF P3300 IS USED AND NO MORE THAN 215LBS IF P3000 IS USEDREF MANUFACTURER'S "GENERAL FITTINGS SPECIFICATIONS" FOR DESIGN BOLT TORQUENO CONNECTION OF ANY KIND SHALL BE MADE TO JOIST WEB MEMBERS OR JOIST BRIDGINGUNISTRUT CAN BE MOUNTED TO THE TOP OF EITHER THE TOP CHORD OR BOTTOM CHORD OF THE BAR JOISTUNISTRUTALL-THREAD SHALL BE A SOLID PIECE. NO SPLICES ALLOWEDPROVIDE AIRCRAFT CABLE SUSPENSION SYSTEM FOR CONNECTION TO ELECTRICAL EQUIPMENTCONTRACTOR HAS THE OPTION TO USE EITHER METHOD OF INSTALLATION SHOWNPROVIDE 1/4" HEX HEAD BOLT, 1-1/4" FENDER WASHER, AND LOCK WASHER, TYPINSETINSETBAR JOIST, TYPUNISTRUTTOP CHORD OF BAR JOIST PROVIDE LOCKING SPRING NUT, TYPPROVIDE UNISTRUT PER SPECIFICATIONS. LENGTH AS REQUIRED TO SPAN JOISTS. SECURE TO TOP CHORD OF BAR JOIST PROVIDE ALL-THREAD CONNECTION TO ELECTRICAL EQUIPMENTPROVIDE 1/4" ALL-THREAD,1-1/4" FENDER WSHER, LOCK WASHER AND NUT, TYPFURNISH AND INSTALLRECEPTACLE AT 8"ABOVE GRID, TYP.PLUG MIRROR IN EACH FITTINGROOM INTO RECEPTACLESABOVE GRID, TYP.ROUTE CONDUIT ABOVE GRIDALONG INSIDE PERIMETER OFFITTING ROOM WALL, TYP.GLOBAL LED EDGELIT PANEL MOUNTEDIN GRID, TYP3/4" C FORDATAJWALL VIEW8"WALL VIEWFRONTDESKFITTINGROOMSROUTE POWER/DATA ALONG BACKSIDE OF ROOM WITH ELECTRICAL DEVICE BOXES UNDERNEATH THE DESK.ROUTE POWER AND DATACONDUIT DOWN THISCORNER OF THE WALLFITTING ROOM WALLGRIDPENETRATE GRID IN CORNERPOWERJUNCTION BOXROUTE POWER/DATA CONDUITS AS SHOWN TO FRONT DESK DEVICESVOICE/DATAOUTLETQUADRECEPTACLEFLOORPOWER/DATA CONDUIT DROP LOCATIONPROVIDE TWISTLOCK RECEPTACLE. SIZE RECEPTACLE BASED ON RATINGS OF EQUIPMENT BEING SERVEDCONNECTOR AS SPECIFIED FOR EQUIPMENTDROP CORD TO BE TYPE SO"KELLUMS" STRAIN RELIEF CONTAINMENT GRIPJUNCTION BOX SECURED TO BAR JOIST OR UNISTRUTPROVIDE UNISTRUT PER SPECIFICATIONS. LENGTH AS REQUIRED TO SPAN JOISTS. SECURE TO BOTTOM CHORD OF BAR JOISTarchitecture2809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209+engineeringEngineer of RecordKeith Allen Williams, P.E.Washington License No. 43345SHEET:DRAWN BY:CHECKED BY:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTIONDOCUMENT DATE:PROTO:PROTO CYCLE:17601-31-202003-11-2020E3ELECTRICALDETAILSBMSYELM, WASHINGTON2019.0835YELM, WASHINGTON03/11/2020STORE NO: 3705-232SUPKAWARSOSBDHJSSOS2SOSS3S4SDSMSVSSKSS SINGLE POLE SWITCH CIRCUIT, CONCEALED IN WALLS ORCEILING, E INDICATES EXISTING WIRINGSMOKE DETECTORSAIL SWITCHJUNCTION BOXHORN / STROBEABBREVIATIONSBUZZERCIRCUIT, CONCEALED IN SLAB FLOOR,E INDICATES EXISTING WIRINGCONDUIT SLEEVESURFACE MOUNTED PANELBOARDFLUSH MOUNTED PANELBOARDCIRCUIT, EXPOSED,E INDICATES EXISTING WIRINGLOW VOLTAGE WIRINGTELEPOWER POLETELEPHONE / DATA BOX FOR ISDTELEPHONE, FLUSH FLOORPUSH BUTTONMOTORALARM JUNCTION BOX,FOR REMOTE TEST/RESET(WALL MOUNTED/CEILING MOUNTED)EQUIPMENT CONNECTION POINT(PROVIDED WITH EQUIPMENT)NON-FUSED DISCONNECTRECEPTACLE, PLUG-MOLDRECEPTACLE, SIMPLEXRECEPTACLE, SPECIALJUNCTION BOX(WALL MOUNTED/CEILING MOUNTED)ALARM JUNCTION BOX,(WALL MOUNTED/CEILING MOUNTED)RECEPTACLE, DOUBLE DUPLEX,ISOLATED GROUNDFUSED DISCONNECT4-WAY SWITCHRECEPTACLE, DUPLEX ISOLATEDGROUND FLUSH FLOORRECEPTACLE, DOUBLE DUPLEXRECEPTACLE, DUPLEX FLUSH FLOORVARIABLE SPEED SWITCHKEYED SWITCHDIMMER SWITCHRECEPTACLE, DUPLEX,MOUNTED HORIZONTALLYRECEPTACLE, DUPLEXMANUAL MOTOR SWITCH3-WAY SWITCHRECEPTACLE, DUPLEXISOLATED GROUNDLIGHT FIXTURE,NIGHT LIGHTVOLUMETRIC LIGHT FIXTURELIGHT FIXTURE(WALL MOUNTED/CEILING MOUNTED)LIGHT FIXTURE(SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS)SYMBOLDESCRIPTIONRECEPTACLE, DUPLEX TWIST LOCK,ISOLATED GROUND, L5-15R, UNOSINGLE POLE OCCUPANCY SENSOR SWITCHLOW VOLTAGE CABLEBOX FOR OTHERDOOR HOLD OPENRECEPTACLE, DUPLEX TWIST LOCK,L5-15R, UNORECEPTACLE, SIMPLEX TWIST LOCK,ISOLATED GROUND, L5-15R, UNORECEPTACLE, SIMPLEX TWIST LOCK,L5-15R, UNOCEILING MOUNTED OCCUPANCY SENSOR SWITCHRECEPTACLE, GFIDOUBLE POLE OCCUPANCY SENSOR SWITCHTTHERMOSTAT(WALL MOUNTED/CEILING MOUNTED)EXIT FIXTURE(WALL MOUNTED/CEILING MOUNTED)EMERGENCY LIGHT(WALL MOUNTED/CEILING MOUNTED)EMERGENCY LIGHT REMOTE HEADS(WALL MOUNTED/CEILING MOUNTED)a, b, c LOWER CASE LETTERS INDICATESWITCHING CONFIGURATIONAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEC CONDUITCCT CIRCUITCF CEILING FANCW CASH WRAPEC ELECTRICAL CONTRACTOREF EXHAUST FANETR EXISTING TO REMAINEWC ELECTRIC WATER COOLERG GROUNDGC GENERAL CONTRACTORGFEP GROUND FAULT EQUIPMENT PROTECTIONGFI GROUND FAULT CIRCUIT INTERRUPTERHD HAND DRYER IG ISOLATED GROUNDLCU LIGHTING CONTROL UNITNL NIGHT LIGHTNTS NOT TO SCALEREC REFRIGERATION ELECTRICAL CONTRACTORRC REFRIGERATION CONTRACTORRH RADIANT HEATERSC SECURITY CAMERATR TAMPER RESISTANTTYP TYPICALUH UNIT HEATERUNO UNLESS NOTED OTHERWISEWH WATER HEATERWP WEATHER PROOFWR WEATHER RESISTANTELECTRICAL SYMBOLS LEGENDTIME CLOCKTCTRACK LIGHTING03.29.191.A.B.C.D.E.2.A.B.C.D.3.4.A.B.C.5.6.7.8.9.10.11.12.13.14.15.16.A.B.C.D.17.A.B.C.D.E.F.18.19.A.B.C.D.FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND LABOR, FOR A COMPLETE INSTALLATION IN ALL RESPECTS, READY FOR INTENDED USE AND IN STRICT ACCORDANCE WITH NEC, NESC, STATE, AND LOCAL CODES, AND MANUFACTURER'S RECOMMENDATIONS. PAY ALL NECESSARY FEES AND PERMITS.NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS THE ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR WALLS.ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE.ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO STORE OPERATIONS. COORDINATE ALL DISRUPTIONS WITH WALMART CONSTRUCTION MANAGER AND STORE MANAGER.CONTRACTOR SHALL VERIFY ALL WALL FINISH THICKNESS BEFORE INSTALLING BOXES. FURNISH AND INSTALL EXTENDED BOXES OR BOX EXTENDERS WHERE REQUIRED.CONTRACTOR SHALL VERIFY THAT ALL AFFECTED PANELBOARDS HAVE CIRCUIT BREAKER KNOCKOUTS PROPERLY COVERED ANDTHAT ALL TRIM IS IN GOOD CONDITION, ALLOWING NO ACCESS TO LIVE PARTS.PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS:FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE STOPPING.NEUTRALIZATION AREA: SEAL PER MECHANICAL DETAIL.FREEZER/COOLER BOXES: SEAL WITH EXPANDING FOAM SEALANT.EXTERIOR: REFER TO ARCHITECTURAL DOCUMENTS FOR SEALING REQUIREMENTS AT ALL EXTERIOR MOUNTED DEVICES, FIXTURES, ENCLOSURES, AND RACEWAY PENETRATIONS.PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR (SIZE PER NEC) IN PVC TYPE CONDUIT, POWER AND LIGHTING CIRCUITS, ISOLATED GROUND CIRCUITS, OR AS SHOWN ON PLANS. CONDUIT SHALL BE SIZED PER NEC BASED ON THWN 600 VOLT COPPER SINGLE CONDUCTORS, PLUS THE EQUIPMENT GROUNDING CONDUCTOR.WIRING DEVICES: DEVICE MOUNTING HEIGHTS ARE FROM FINISHED FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED OTHERWISE ON PLANS. COORDINATE THE STANDARD MOUNTING HEIGHTS WITH MASONRY:SWITCHES +44"RECEPTACLES +20"VOICE/DATA +20"WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT IN CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING DIAGRAMS.CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE PANELBOARD IDENTIFICATION SCHEDULES FOR PANELBOARDS AFFECTED BY REMODEL.NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN EXISTING PANELBOARDS OR DISTRIBUTION BOARDS SHALL MATCH THE TYPE AND AIC RATING OF EXISTING OVERCURRENT PROTECTIVE DEVICES.BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG UNLESS NOTED OTHERWISE IN SCHEDULES. WHERE 20A BRANCH CIRCUITS HAVE #8 AND LARGER WIRE SPECIFIED, #10 AWG WIRE SHALL BE USED FOR THE FINAL CONNECTION (15-FT MAXIMUM).WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND DERATE CURRENT CARRYING CONDUCTORS PER NEC.PROVIDE UL LISTED HANDLE TIES ON ALL MULTIWIRE BRANCH CIRCUITS PER NEC REQUIREMENTS.SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE SHALL BE MADE TO BRIDGING OR JOIST WEB MEMBERS. UTILIZE ONLY THE TOP AND BOTTOM CHORDS FOR SUPPORTING THE ELECTRICAL SYSTEM INSTALLATIONS. DEVICES SHOWN ON COOLER/FREEZER PANELS SHALL BE SURFACE MOUNTED UNLESS NOTED OTHERWISE. SEAL DEVICES TO COOLER/FREEZER PANELS WITH SILICONE SEALANT.SURFACE MOUNTED CONDUIT ON COOLER/FREEZER PANELS OR IN FOOD PREP AREAS SHALL BE INSTALLED WITH GALVANIZED 1/2" STANDOFF CONDUIT HANGERS TO ALLOW FOR CLEANING.ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM AND BRANCH CIRCUITS NOTED BY LEGEND SHALL BE INSTALLED UNDER SLAB. PROVIDE EXTERIOR COATED GRC BENDS ON ALL CONDUIT RUNS THAT HAVE 45 DEGREE BENDS OR GREATER. REFER TO SPECIFICATION SECTION 16.100 FOR UNDER SLAB.SEISMIC ZONE REQUIREMENTS: PROVIDE EXPANSION COUPLINGS AND BRACING FOR ELECTRICAL EQUIPMENT AS REQUIRED BY LOCAL CODES.EXISTING ELECTRICAL AND ALARM:WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING EQUIPMENT, DEVICES, OR LIGHTING TO REMAIN, BUT NOT SHOWN ON DRAWINGS, PROVIDE LABOR AND MATERIALS TO REWORK CIRCUITRY, AS REQUIRED, TO MAINTAIN EXISTING OPERATION.IF DEMOLITION OR NEW CONSTRUCTION WILL DISRUPT EXISTING UNDERGROUND SERVICES (ELECTRICAL, TELEPHONE, PARKING LOTLIGHTING CIRCUITRY, ETC.) PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO REROUTE, SLEEVE, OR OTHERWISE REWORK THESE SERVICES TO MAINTAIN THEIR EXISTING OPERATION.EXERCISE CAUTION AROUND ALARM AND SECURITY CABLES DURING DEMOLITION AND CONSTRUCTION. PROTECT ALARM AND SECURITY CABLES FROM ACCIDENTAL DAMAGE SO THAT SYSTEMS REMAIN OPERATIONAL AT ALL TIMES.DISPOSE OF ALL REMOVED MATERIALS, UNLESS OTHERWISE NOTED.EXISTING ELECTRICAL DEMOLITION:GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL EQUIPMENT, CONDUIT AND CONDUCTORS AS INDICATED ON THE DRAWINGS, OR ONLY AS REQUIRED BY DEMOLITION. REMOVE ALL PANELBOARDS, DISCONNECT SWITCHES, BOXES, RELAYS, TIME SWITCHES, LIGHTS, DEVICES, ETC., WHICH WILL NOT BE REUSED.SALES FLOOR: REMOVE UNUSED POWER DROP CONDUIT, CONDUCTORS AND RELATED DEVICES SERVING SALES AREA GONDOLAS BEING RELOCATED OR REMOVED. EXISTING CONDUIT AND CONDUCTORS MAY BE REUSED FOR NEW POWER DROPS WHERE SIZE, RATING, AND CONDITION MEET REQUIREMENTS INDICATED ON PLANS AND ALL U.L. RATINGS. REMOVE ALL UNUSED CONDUIT AND CONDUCTORS BACK TO POINT OF ORIGIN WHENEVER FEASIBLE AND RELABEL DEMOLISHED CIRCUITS AS "SPACE". REMOVE CIRCUIT BREAKER AND REPLACE WITH FILLER PLATE. UPDATE TYPEWRITTEN CIRCUIT DIRECTORY IDENTIFYING CIRCUIT AS "SPACE".CONDUIT AND WIRING TO BE ABANDONED IN CEILING SPACES AND OTHER NON-PUBLIC AREAS (I.E., THROUGH STOCKROOM AREA): CUT WIRING LOOSE AND REMOVE FROM RACEWAY(S), LEAVING RACEWAY(S) IN PLACE. CONDUIT TO BE ABANDONED IN WALLS OR FLOORS SHALL BE REMOVED BACK TO FINISHED SURFACE AND CAPPED INSIDE. REPAIR SURFACE(S) TO MATCH ADJACENT.ALL CIRCUIT BREAKERS SERVING BRANCH CIRCUITS TO BE REMOVED SHALL ALSO BE REMOVED. REMOVE CIRCUIT BREAKER AND REPLACE WITH FILLER PLATE. UPDATE TYPEWRITTEN CIRCUIT DIRECTORY IDENTIFYING CIRCUIT AS "SPACE".DEMOLISHED FLUORESCENT LIGHT FIXTURES: REFER TO SELECTIVE SITE DEMOLITION SPECIFICATION FOR DISPOSAL OF LIGHT FIXTURE.BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE FUTURE.DATA AND PHONE CONDUIT INSTALLATION MILESTONE DATE:ALL RACEWAY AND CONDUIT SLEEVES FOR DATA AND PHONE CABLING TO BE INSTALLED 3 WEEKS PRIOR TO CONTRACT SUBSTANTIAL COMPLETION DATE.ETHERNET CABLE:FURNISH AND INSTALL JUNCTION BOXES AS SHOWN ON PLANS. PROVIDE CONDUIT AS REQUIRED BY LOCAL CODES AND/OR ORDINANCES.ETHERNET CABLE IS FURNISHED BY OTHERS.ELECTRICAL CONTRACTOR SHALL INSTALL CABLE IN POWER POLES.ELECTRICAL CONTRACTOR SHALL INSTALL OTHER CABLE AS DIRECTED BY WALMART CONSTRUCTION MANAGER.GENERAL NOTES08.02.19NTS1POWER POLE CONNECTIONNTS2GENERAL ELECTRICAL CONNECTIONS TO STRUCTURENTS3FITTING ROOM LIGHTING/POWER PLANNTS4SUSPENDED DROP CORD - OPEN STRUCTURESCHEDULE GENERAL NOTES:ROUGH-IN NOTES:DROPcbaSURFACE MOUNT JUNCTION BOX AT +66" (UNO) WITH (1) 3/4" CONDUIT STUBBED TO ACCESSIBLE CEILING SPACE.FLUSH MOUNT JUNCTION BOX AT +20" (UNO) WITH (1) 3/4" CONDUIT ROUTED TO NEAREST ACCESSIBLE CEILING SPACE.FLUSH MOUNT JUNCTION BOX AT +20" (UNO) WITH (1) 3/4" CONDUIT STUBBED 12" ABOVE LAY-IN CEILING.1.2.3.4.5.6.7.8.ALL JUNCTION BOXES SHALL BE DOUBLE GANG WITH SINGLE GANG PLASTER RING UNLESS NOTED OTHERWISE ON SCHEDULE.ALL JUNCTION BOXES TO BE ROUGHED IN AT SCHEDULED HEIGHT UNLESS NOTED OTHERWISE ON DRAWINGS.ALL CONDUITS SHALL BE TERMINATED WITH BUSHINGS.PROVIDE PULL WIRE WITH EACH EMPTY RACEWAY (JUNCTION BOX/CONDUIT) INSTALLED.CONDUIT RUNS SHALL HAVE NO MORE THAN 90 DEGREES OF TRANSITION BETWEEN PULL BOXES.WHERE CONDUIT(S) TRAVERSE AREAS WITH CEILINGS OPEN TO STRUCTURE, CONDUIT(S) SHALL BE CONCEALED AS WELL AS POSSIBLE FROM VIEW FROM CUSTOMER AREA.FOR CONDUIT RUNS SCHEDULED WITH 1-1/2" OR LARGER CONDUIT UTILIZE LARGE RADIUS SWEEPS AT POINTS OF TRANSITION.ACCESSIBLE CEILING SPACE SHALL BE CONSIDERED 12 INCHES ABOVE A LAY-IN CEILING OR ABOVE BAR JOIST ACCESSIBLE BY A SCISSOR LIFT FOR AREAS OPEN TO STRUCTURE.VOICE/DATA ROUGH-IN SCHEDULE09.27.19ISSUE BLOCK