2020.0103.BPP0008 4090 - RE1 REFRIGERATION ELECTRICAL PLANS - 3705JJJJS
SJJJJJJJJJJJC23RCU-2RCU-2RCU-2MTF-616.14516.145CHL-3 CHFF-716.14516.145CHL-5 CHFF-9PROVIDE 3/4"C FROM LOW VOLTAGEWIRING COMPARTMENT TOACCESSIBLE INTERIOR JOIST SPACEAND TERMINATE WITH BUSHINGS.WR,WP,GFI16.250REMOTE CONDENSING UNITRCU-2, MOUNTED ON ROOFL4D1-80,82,8416.477(50A-3P)DISCONNECT WITHOVERCURRENT PROTECTIONPROVIDED WITH UNIT.REFRIGERATED CASE ELECTRICAL CONNECTION POINT, TYPNOTE: PROVIDE 120V LIQUID LINE SOLENOID VALVE WIRING ((2)#12W W/ (1)#12W GND) AT EACH CIRCUIT. TERMINATION OF 120V WIRING AT CASE/EVAPORATOR SOLENOID VALVE AND AT BAS CONTROLLER BY R.C. SOLENOID WIRING NOT SHOWN ON PLAN FOR CLARITY. COORDINATE EXACT LOCATION OF SOLENOID VALVES WITH R.C. PRIOR TO INSTALLATION.REFERENCE 1-E2 FOR REFRIGERATION RACKS AND REFRIGERATION RACK PANELS4RE1TYP16.711CHFF-216.14516.708#8WREFRIGERATED CASE ELECTRICAL CONNECTION POINT, TYPNOTE: PROVIDE 120V LIQUID LINE SOLENOID VALVE WIRING ((2)#12W W/ (1)#12W GND) AT EACH CIRCUIT. TERMINATION OF 120V WIRING AT CASE/EVAPORATOR SOLENOID VALVE AND AT BAS CONTROLLER BY R.C. SOLENOID WIRING NOT SHOWN ON PLAN FOR CLARITY. COORDINATE EXACT LOCATION OF SOLENOID VALVES WITH R.C. PRIOR TO INSTALLATION.REFERENCE 1-E2 FOR REFRIGERATION RACKS AND REFRIGERATION RACK PANELS3RE1REMOTE CONDENSING UNITRCU-1, MOUNTED OF ROOFWR,WP,GFIDISCONNECT WITHOVERCURRENT PROTECTIONPROVIDED WITH UNIT.(60A-3P)GH23416.250PROVIDE 3/4'C FROM LOW VOLTAGEWIRING COMPARTMENT TOACCESSIBLE INTERIOR JOIST SPACEAND TERMINATE WITH BUSHINGS.-L4D1 74,76,7816.477MTE-1MTE-1MTE-1CHL-32CHFE-19CHL-3016.145CHFE-2116.14516.14516.145RCU-1RCU-1RCU-1RCU-1RCU-1RCU-1CHFE-2316.477MTE-9MTE-9TYP16.711#6W16.489REFRIGERATEDCASESMTE-1 & MTE-9(20A-1P)ROUTE EMT CONDUITS TO POINT OF TRANSITION TO FLEXSECURE CONDUIT TO FLOOR OR TOP OF CASE AS REQUIRED BY CODE, TYPPROVIDE TRANSITION FROM EMT TO LIQUID-TIGHT FLEXIBLE METAL CONDUITBRANCH CIRCUIT CONDUITS TO OTHER REFRIGERATED CASE SYSTEMS, TYPTERMINATION TO REFRIGERATED CASE ELECTRICAL CONNECTION POINT BY R.C.12" WIRE PIGTAILS TYP5' FLEX CONDUIT TYPROUTE CONDUIT FOR BRANCH CIRCUITS FROM OVERHEAD ALONG WITH REFRIGERATION PIPING. CONDUIT SHALL BE ROUTED THROUGH CHASE WHERE INDICATED ON PLANSPROVIDE (2) CONDUITS AND BRANCH CIRCUITS PER REFRIGERATED CASE SYSTEM. ONE CONDUIT WILL SERVE 120V CASE FANS, LIGHTS AND ANTI-SWEAT CIRCUITS. ONE CONDUIT WILL SERVE 208V CASE ELECTRIC DEFROST CIRCUIT. ON SYSTEMS WITHOUT ELECTRIC DEFROST, ONLY PROVIDE ONE CONDUIT. REFERENCE PLANS FOR ADDITIONAL EMS CONDUIT AT CHASE LOCATION.PVC CHASE WHERE INDICATED ON PLANSFLOOR OR TOP OF CASE. COORDINATE TOP OR BOTTOM FED CASE ELECTRICAL CONNECTION WITH ARCHITECTURAL PLANSCONDUITS FOR REFRIGERATED CASE SYSTEM: CONDUIT(S) WILL SERVE 120V CASE FAN, CASE LIGHT AND CASE ANTI-SWEAT CIRCUITS. IN ADDITION, CONDUIT(S) WILL SERVE 208V CASE ELECTRIC DEFROST CIRCUIT (IF APPLICABLE). NOTE: CIRCUITS MAY BE GROUPED TOGETHER TO MINIMIZE NUMBER OF CONDUITS PROVIDED THAT ALL NEC REQUIREMENTS ARE METTERMINATION TO REFRIGERATED CASE ELECTRICAL CONNECTION POINT BY R.C.PROVIDE TRANSITION FROM PVC TO EMTTYPICAL REFRIGERATED CASE SYSTEMROUTE EMT CONDUITS (UNDER CASES, ABOVE SLAB) TO POINT OF TRANSITION TO FLEX5' FLEX CONDUIT TYP12" WIRE PIGTAILS TYPBRACKET CONDUIT TO FLOOR AS REQUIRED PER CODE TYPPROVIDE TRANSITION FROM EMT TO FLEXREFRIGERATION PITUNDERSLAB PVC CONDUIT FOR REFRIGERATED CASE BRANCH CIRCUITS FLOORarchitecture2809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209+engineeringEngineer of RecordKeith Allen Williams, P.E.Washington License No. 43345SHEET:DRAWN BY:CHECKED BY:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTIONDOCUMENT DATE:PROTO:PROTO CYCLE:17601-31-202003-11-2020RE1REFRIGERATIONELECTRICALPLANSBMSYELM, WASHINGTON2019.0835YELM, WASHINGTON03/11/2020STORE NO: 3705-232SUPKAWNOTE: REFRIGERATION CONTRACTOR IS RESPONSIBLE FOR ALL FINAL REFRIGERATION ELECTRICAL TERMINATIONS TO REFRIGERATION EQUIPMENT 1/8" = 1'-0" 1FRONT REFRIGERATION POWER PLAN 1/8" = 1'-0" 2REAR REFRIGERATION POWER PLANKEYNOTES16.145 CONNECT CIRCUIT(S) TO EXISTING BRANCHCIRCUITRY. MINIMUM WIRE SIZE ANDPANELBOARD CIRCUIT ARE NOTED. VERIFY SIZE,RATING AND CONDITION OF EXISTING BRANCHCIRCUIT CONDUIT AND WIRE PRIOR TO USE TOENSURE THAT THEY MEET REQUIRED SIZE, ANDALL U.L. RATINGS AND REPLACE AS REQUIRED.16.250 CONNECT CIRCUITRY TO FACTORY PROVIDEDMAINTENANCE RECEPTACLE. ROUTE CIRCUIT TONEAREST RTU OR AHU MAINTENANCERECEPTACLE CIRCUIT16.477 FURNISH AND INSTALL NEW CIRCUIT BREAKER(##A-#P) IN EXISTING PANELBOARD INDICATED.PROVIDE CIRCUIT BREAKER LOCKING DEVICE(LOCK-OFF FOR MAINTENANCE). E.C. SHALLMATCH MANUFACTURER, TYPE AND AIC RATINGSOF EXISTING CIRCUIT BREAKERS.16.489 RELOCATE, EXTEND, AND RECONNECTCIRCUITRY AND ELECTRICAL DEVICES FORRELOCATED AND/OR NEW EQUIPMENT. VERIFYCONDITION OF BRANCH CIRCUITRY, CONDUITAND WIRE TO ENSURE THEY MEET ALL U.L.RATINGS AND REPLACE AS REQUIRED. VERIFYFINAL LOCATION OF RELOCATED/NEWEQUIPMENT WITH WALMART CONSTRUCTIONMANAGER PRIOR TO ROUGH-IN.16.708 PROVIDE WIRING AND FINAL CONNECTIONS TORECEPTACLE. RECEPTACLE FURNISHED WITHREFRIGERATED CASE.16.711 POINT OF TRANSITION FROM EMT TO FLEX.PROVIDE CONDUIT AND BRANCH CIRCUITS FORREFRIGERATED CASE FANS, LIGHTS,ANTI-SWEAT HEATERS, AND ELECTRICALDEFROST (IF REQUIRED). TERMINATION TOREFRIGERATED CASE ELECTRICAL CONNECTIONPOINT BY R.C. REFER TO CASE CONNECTIONWIRING DETAIL.NTS3CASE CONNECTION WIRINGNTS4UNDERSLAB CASE CONNECTION WIRING1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.COORDINATE ALL WORK WITH REFRIGERATION CONTRACTOR (R.C.) PRIOR TO INSTALLATION.REFRIGERATED CASES: E.C. SHALL PROVIDE CONDUIT AND WIRE FOR REFRIGERATED CASE FANS, LIGHTS AND ANTI-SWEAT HEATERS, AND (IF APPLICABLE) ELECTRICAL DEFROST. PROVIDE ADEQUATE CONDUCTOR LENGTH TO ALLOW TERMINATION. NEATLY BUNDLE CIRCUITS AND CLEARLY TAG AND LABEL EACH CIRCUIT WITH BRANCH CIRCUIT DESIGNATION AND REFRIGERATION SYSTEM NUMBER FOR FINAL TERMINATION AT CASE BY R.C. REF CASE CONNECTION WIRING DETAIL.NEW CASES ARE PROVIDED WITH A FACTORY INSTALLED TERMINAL STRIP AND JUMPERS FOR CONNECTION TO A SINGLE CIRCUIT FOR 120V CASE LOADS. RC SHALL REMOVE FACTORY INSTALLED JUMPERS AS REQUIRED TO UTILIZE EXISTING SEPARATE 120V FAN/LIGHT/ANTI-SWEAT CIRCUITS AS INDICATED ON PLANS AND/OR PANELBOARD SCHEDULES. ANY EXISTING ANTI-SWEAT CONTROL (SWEATMISER) SHALL BE BY-PASSED. CASES UTILIZING ELECTRICAL DEFROST WILL BE PROVIDED WITH SEPARATE 208V TERMINATIONS AT THE TERMINAL STRIP FOR CONNECTION TO THE 208V ELECTRIC DEFROST CIRCUIT. RC SHALL MAKE FINAL TERMINATIONS OF 120V AND 208V POWER CIRCUIT(S) AT CASE TERMINAL STRIP. REFER TO CASE CONNECTION SCHEMATIC ON REFRIGERATION SHEETS.WALK-IN UNITS: PROVIDE CONDUIT AND WIRE FOR EVAPORATOR COIL FANS (CF) AND (IF APPLICABLE) ELECTRIC DEFROST (ED). PROVIDE ADEQUATE CONDUCTOR LENGTH TO ALLOW TERMINATION. NEATLY BUNDLE CIRCUITS AND CLEARLY TAG AND LABEL EACH CIRCUIT WITH BRANCH CIRCUIT DESIGNATION AND REFRIGERATION SYSTEM NUMBER FOR FINAL TERMINATION AT COIL BY R.C. REF EVAPORATOR COIL WIRING DETAIL.ROUTE REFRIGERATED CASE AND WALK-IN UNIT COIL FAN, LIGHTS, ANTI-SWEAT AND DEFROST BRANCH CIRCUITS TO WIREWAYS PROVIDED AT REFRIGERATION EQUIPMENT AND/OR PANELBOARDS AS REQUIRED. REFRIGERATED CASE WIRING COMPARTMENT REPRESENTED ON DRAWING BY JUNCTION BOX.KEEP PENETRATIONS THROUGH WALK-IN UNITS TO A MINIMUM. ROUTE ALL CONDUITS SERVING FREEZERS AND COOLERS ON INSIDE OF BOX.ALL CONDUITS INSTALLED ON TOP OF WALK-IN UNITS SHALL BE A MINIMUM OF 6" FROM ANY EDGE TO ALLOW SPACE FOR EDGE PROTECTION NETTING. DO NOT ROUTE CONDUITS ABOVE THE CEILING GRID ACCESS UNLESS CONDUITS ARE INSTALLED IN JOIST SPACE, REF ARCH.UNDERSLAB CIRCUITS SHALL NOT BE ROUTED UNDER WALK-IN FREEZERS AND SHALL BE ROUTED ABOVE REFRIGERANT LINES WHERE THEY CROSS.CIRCUITS FOR REFRIGERATED CASES SERVED BY UNDERSLAB REFRIGERATION PIPING ARE TO BE ROUTED UNDERSLAB AND EXTENDED TO THE FIRST CASE IN EACH SYSTEM. WIRING AND CONDUIT FOR SLAVE WIRING BETWEEN CASES SHALL BE PROVIDED BY R.C. REFER TO UNDERSLAB CASE CONNECTION WIRING DETAIL.ALL UNDERSLAB CONDUITS SHALL BE 3/4" MIN.CIRCUITS FOR REFRIGERATED CASES SERVED BY OVERHEAD REFRIGERATION PIPING ARE TO BE ROUTED DOWN FROM STRUCTURE AT THE SAME LOCATION AS THE REFRIGERATION PIPING AND EXTENDED TO THE FIRST CASE IN EACH SYSTEM. WIRE AND CONDUIT FOR SLAVE WIRING BETWEEN CASES SHALL BE PROVIDED BY THE R.C. REFER TO OVERHEAD CASE CONNECTION WIRING DETAIL. ON GROUPS OF THREE OR MORE REFRIGERATED CASES WITH ELECTRIC DEFROST, R.C. SHALL CONNECT CASES TO CREATE A THREE-PHASE HEATER CIRCUIT. HEATER LOADS SHALL BE BALANCED BETWEEN PHASES AS EVENLY AS POSSIBLE. REF CASE DEFROST WIRING DETAIL.PROVIDE A SEPARATE NEUTRAL FOR EACH BRANCH CIRCUIT SERVING REFRIGERATED CASES OR WALK-IN UNITS AS INDICATED ON PLANS.PROVIDE CIRCUIT BREAKER LOCKING DEVICE (LOCK-OFF FOR MAINTENANCE) ON NEW AND/OR EXISTING CIRCUIT BREAKERS SERVING REFRIGERATED CASE ANTI-SWEAT HEATERS OR DRAIN HEATERS.REFERENCE ARCHITECTURAL DEMOLITION PLANS FOR FULL EXTENT OF DEMOLITION WORK REQUIRED.GENERAL REFRIGERATION ELECTRICAL NOTES12.21.18PER NEC ARTICLE 220 FEEDER LOAD 28.95 KVA80.36 AMPSTOTAL LOAD 23.16 KVA64.29 AMPSTOTAL CONNECTED 67.0168.6059.42 AMPSTOTAL CONNECTED 7.928.117.13 KVA41 a-11 case ltg (13)20 A 10.67 0.66 1 20 Adairy cooler door ltg (13)4239 a-10 case ltg (13)20 A 10.29 0.171 20 Ae-7 case ltg (13)4037 a-2 case ltg (13)20 A 1 0.17 0.761 20 Ae-6 case ltg (13)3835 SPACE (11)-- -- --0.00 0.50 1 20 Ae-3 case ltg (13)3633 SPACE (11)-- -- --0.00 0.501 20 Ae-2 case ltg (13)3431 d-7 case ltg (13)20 A 1 0.60 0.541 20 AE-1 CASE LTG (13)3229 d-6 case ltg (13)20 A 10.50 0.50 1 20 AE-9 CASE LTG (13)3027 d-5 case ltg (13)20 A 10.50 0.00-- -- -- SPACE (11)2825 d-3 case ltg (13)20 A 1 1.48 0.00-- -- -- SPACE (11)2623 d-2 case ltg (13)20 A 11.11 0.76 1 20 Ac-8 case ltg (13)2421 d-1 case ltg (13)20 A 11.11 0.701 20 Ac-3 case ltg (13)2219 SPACE (11)-- -- -- 0.00 0.761 20 Ac-2 case ltg (13)2017 SPACE (11)-- -- --0.00 0.00 -- -- -- SPACE (11)1815 f-12 case ltg (13)20 A 10.17 1.101 20 Ab-8 case ltg (13)1613 f-11 case ltg (13)20 A 1 0.50 0.931 20 Ab-7 case ltg (13)1411 f-10 case ltg (13)20 A 10.40 1.10 1 20 Ab-6 case ltg (13)129 f-8 case ltg (13)20 A 10.80 0.931 20 Ab-5 case ltg (13)107 f-7 case ltg (13)20 A 1 0.15 1.101 20 Ab-4 case ltg (13)85 SPACE (11)-- -- --0.00 0.93 1 20 Ab-3 case ltg (13)63 F-6 CASE LTG (13)20 A 10.74 1.101 20 Ab-2 case ltg (13)41 SPACE (11)-- -- -- 0.00 0.931 20 Ab-1 case ltg (13)2DESCRIPTIONWIRE BRKR PL ABC PL BRKR WIREDESCRIPTIONLOCATION: COMPRESSOR RACK "E"SERVES: REFRIGERATED CASE LIGHTS(EXISTING)225 A, M.L.O.CHLPANELBOARD208Y/120 V, 3PH, 4WPER NEC ARTICLE 220 FEEDER LOAD 9.18 KVA25.49 AMPSTOTAL LOAD 9.18 KVA25.49 AMPSTOTAL CONNECTED 19.8829.2329.91 AMPSTOTAL CONNECTED 2.393.363.44 KVA23 RCU-1 FANS (2,19)20 A 10.36 0.00 -- -- -- space2421 E-9 CASE FANS (13)20 A 10.17 0.00-- -- -- space2219 E-1 CASE FANS (13)20 A 1 0.58 0.00-- -- -- space2017 dairy cooler door htrs (13)20 A 11.21 0.00 -- -- -- space1815 e-8 coil fans (13)20 A 11.51 0.00-- -- -- space1613 e-7 case fans (13)20 A 1 0.13 0.00-- -- -- space1411 e-6 case fans (13)20 A 10.57 0.00 -- -- -- space129 e-5 coil fans (13)20 A 11.30 0.00-- -- -- space107 e-4 coil fans (13)20 A 1 1.30 0.00-- -- -- space85 e-5 coil fans (13)20 A 11.30 0.00 -- -- -- space63 e-3 case fans (13)20 A 10.38 0.00-- -- -- space41 e-2 case fans (13)20 A 1 0.38 0.00-- -- -- space2DESCRIPTIONWIRE BRKR PL ABC PL BRKR WIREDESCRIPTIONLOCATION: COMPRESSOR RACK "E"SERVES: REFRIGERATED CASE FANS, RECEPTACLES, & A/S...(EXISTING)100 A, M.L.O.CHFEPANELBOARD208Y/120 V, 3PH, 4WPER NEC ARTICLE 220 FEEDER LOAD 5.17 KVA14.36 AMPSTOTAL LOAD 5.17 KVA14.36 AMPSTOTAL CONNECTED 21.5818.296.42 AMPSTOTAL CONNECTED 2.402.000.77 KVA23 SPACE (11)-- -- --0.00 0.00 -- -- -- space2421 f-12 case fans (13)20 A 10.19 0.00-- -- -- space2219 f-11 case fans (13)20 A 1 0.57 0.00-- -- -- space2017 f-10 case fans (13)20 A 10.51 0.00 -- -- -- space1815 f-9 case lights & fans (13)20 A 10.58 0.00-- -- -- space1613 f-8 fans & a/s htrs (13)20 A 1 0.60 0.00-- -- -- space1411 f-7 case fans (13)20 A 10.26 0.00 -- -- -- space129 RCU-2 CASE FANS (13)20 A 10.22 0.00-- -- -- space107 F-6 CASE FANS (13)20 A 1 0.62 0.00-- -- -- space85 SPACE (11)-- -- --0.00 0.00 -- -- -- space63 f-3 coil fans (13)20 A 11.01 0.00-- -- -- SPACE (11)41 f-2 coil fans (13)20 A 1 0.43 0.181 20 AF-6 CASE RECEPT (13)2DESCRIPTIONWIRE BRKR PL ABC PL BRKR WIREDESCRIPTIONLOCATION: COMPRESSOR RACK "F"SERVES: REFRIGERATED CASE FANS, RECEPTACLES, & A/S...(EXISTING)100 A, M.L.O.CHFFPANELBOARD208Y/120 V, 3PH, 4WISSUE BLOCK1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.17.18.19.20.21.22.1.2.3.4.TERMINATE GROUND ON ISOLATED GROUND BUS.INSTALL LOCKING DEVICE (LOCK-OFF FOR MAINTENANCE). LOCKING DEVICE SHALL BE UL LISTED. MANUFACTURER SHALL MATCH EXISTING PANELBOARD MANUFACTURER.INSTALL LOCKING DEVICE (LOCK-ON FOR CRITICAL LOAD).GFI BREAKER FOR PERSONNEL PROTECTION (5MA).GFI BREAKER FOR EQUIPMENT PROTECTION (30MA).CONDUCTOR SIZE HAS BEEN INCREASED FOR VOLTAGE DROP. SIZE EQUIPMENT GROUNDING CONDUCTOR PROPORTIONATELY PER NEC.REFER TO ONE-LINE DIAGRAM FOR AVAILABLE FAULT CURRENT FOR INTERRUPT RATINGS.REFER TO ONE-LINE DIAGRAMS FOR WIRE SIZES.FACTORY WIRED TO LOAD.BREAKER SHALL BE HIGH MAGNETIC TYPE.FIELD VERIFY BREAKER IS NOT CONNECTED TO ANY LOAD. REMOVE CIRCUIT BREAKER AND REPLACE WITH BLANK COVER. UPDATE TYPEWRITTEN CIRCUIT DIRECTORY IDENTIFYING CIRCUIT AS "SPACE". IF AN EXISTING LOAD IS CONNECTED, REFER TO PANELBOARD NOTE (22).DUAL TAP SOLENOID OPERATED BREAKER. CONNECT EMERGENCY/NIGHT LIGHTING TO UNSWITCHED TERMINATION.EXISTING CIRCUIT TO REMAIN.ROUTE CIRCUIT THROUGH CONTACTOR.PROVIDE INTERLOCK WIRING WITH EXHAUST HOOD ANSUL SYSTEM.RELOCATED CIRCUIT FROM EXISTING PANELBOARD.PROVIDE BLANK CIRCUIT BREAKER FILLER PLATE FOR EXPOSED SPACE IN PANELBOARD.PROVIDE U.L. LISTED OVERCURRENT DEVICE TO COORDINATE AND MAINTAIN MANUFACTURER'S SERIES RATED SYSTEM.EXISTING CIRCUIT BREAKER TO REMAIN. VERIFY CONDITION OF CIRCUIT BREAKER TO ENSURE THAT IT IS OPERATIONAL AND MEETS ALL U.L. RATINGS.ROUTE CIRCUIT THROUGH EXISTING LCU CABINET UTILIZING EXISTING RELAY AND CONTROLS. UPDATE LCU IDENTIFICATION SCHEDULE WITH LOAD IDENTIFICATION.SOLENOID OPERATED CIRCUIT BREAKER. REFER TO ENERGY MANAGEMENT PLANS FOR CIRCUIT BREAKER CONTROL.TRACE EXISTING CIRCUIT, IDENTIFY LOAD AND PROVIDE COMPLETE TYPEWRITTEN PANELBOARD IDENTIFICATION SCHEDULE AND PLACE ON INTERIOR OF PANELBOARD DOOR. IF CIRCUIT IS A "SPARE", REFER TO PANELBOARD NOTE (11).GENERAL NOTES:E.C. SHALL ADD OR REARRANCE CIRCUIT BREAKERS WITHIN PANELBOARDS AS REQUIRED TO MATCH NEW CIRCUIT DESIGNATIONS SHOWN ON DRAWINGS.NEW OVERCURRENT PROTECTIVE DEVICES PLACED IN EXISTING PANELBOARDS OR DISTRIBUTION BOARDS SHALL MATCH THE TYPE AND AIC RATING OF EXISTING OVERCURRENT PROTECTION DEVICES IN SAID BOARD.E.C. SHALL TRACE ALL ELECTRICAL CIRCUITS FOR ALL EXISTING ELECTRICAL PANELBOARDS AFFECTED BY THE REMODEL AND IDENTIFY LOADS ON EACH CIRCUIT. PROVIDE A COMPLETE TYPEWRITTEN PANELBOARD IDENTIFICATION SCHEDULE FOR ALL AFFECTED PANELBOARDS.ALL OVERCURRENT DEVICES ARE NEW UNLESS NOTED OTHERWISE.PANELBOARD NOTES ()07.26.1920A WIRE SIZING SCHEDULE385 FT.770 FT.930 FT.620 FT.1865 FT.255 FT.ALL WIRE SIZES SHOWN ON PANEL SCHEDULES ARE INTENDED TO BE MINIMUM ACCEPTABLE WIRE SIZE.THE FOLLOWING SCHEDULE IS TO BE USED TO SIZE WIRE FOR 20 AMP CIRCUITS (120 AND 277 VOLT). LENGHTS (IN FEET) ARE INTENDED TO BE MAXIMUM.6-10 AMPS1-5 AMPS120 VOLT11-15 AMPS6-10 AMPS1-5 AMPS277 VOLT11-15 AMPS#8#12#10380 FT.760 FT.250 FT.240 FT.480 FT.160 FT.585 FT.1170 FT.390 FT.325 FT.110 FT.160 FT.#12200 FT.70 FT.100 FT.490 FT.165 FT.245 FT.#10#8#6#6