20180242 Civil Plans Original (NPR Recycling)LEGEND EXISTING —w - -ss- - PTA SO RD ucP— TV — NPR RECYCLING A PORTION OF SECTION 5, TOWNSHIP 17 NORTH, RANGE 02 WEST, W.M. t CITY OF TUMWATER, WASHINGTON ENS ug \\`� \ \ \\ \ ' \ \ \ cv, . 333-' \\ �_ tri SCALE: 1"=60 FEET 0 30 60 120 LOT 1 &LOCK v w. 340 w \ - PROPOSED _ M— WATER MAIN 99— SANITARY SEWER MAIN—FM- -�°, FORCE MAIN \\. SD— STORM MAIN �s \\ Y� \�.. \�'.�:�..�:.... -.•�. .:. .�.' :-.� RD — ROOF DRAIN FOOTING DRAIN G — GAS LINE ucP POWER LINE \ - T — TELEPHONE LINE —CATV— CABLE TV LINE - ROADWAY CENTERLINE � — �\\ \• ' APPLICANT: UBAIDA MUFREJ — - - — — - - — RIGHT-OF-WAY LINE \ - - — — - - EASEMENT LINE SITE ADDRESS: NPR HOLDINGS, LLC FRONT/BACK OF CURB \ YELM, WA 98597 ZONING: I - INDUSTRIAL SITE AREA: EDGE of GRAVEL SHOULDER _ - - - - - EDGE OF GRAVEL SHOULDER EDGE OF PAVEMENT EDGE OF PAVEMENT SOILS: MART SILT LOAM SANITARY SEWER: CITY OF YELM L07 3 u 6( FIRE HYDRANT BLOCK 9 W N GATE VALVE ow 0 WATER METER BOX 0 STORM DRAIN CATCH BASIN OS • SEWER MANHOLE E STREET LIGHT \� \ DEEA\RSF VICINITY MAP N.T.S. nul PROJECT INFORMATION APPLICANT: UBAIDA MUFREJ 3655 MARGINAL WAY S. #203 SEATTLE, WA 98134 (206) 313-0256 PARCEL NOS: 64300900200 SITE ADDRESS: NPR HOLDINGS, LLC 939 NORTHERN PACIFIC RD. YELM, WA 98597 ZONING: I - INDUSTRIAL SITE AREA: 606,420 SF/ 13.921 ACRES GRADING: CUT = 12,200 CY FILL = 10,230 CY NET = 1,970 CY SOILS: MART SILT LOAM SANITARY SEWER: CITY OF YELM WATER: CITY OF YELM FIRE DISTRICT: THURSTON COUNTY SHEETINDEX CO.1 CIVIL COVER SHEET C1.1 HORIZONTAL CONTROL PLAN C1.2 HORIZONTAL CONTROL NOTES AND DETAILS C2.1 TEMPORARY EROSION AND SEDIMENT CONTROL PLAN C2.2 TESC NOTES AND DETAILS C3.1 SITE GRADING AND DRAINAGE PLAN C3.2 YARD GRADING AND DRAINAGE PLAN C3.3 DRAINAGE NOTES AND DETAILS C3.4 DRAINAGE NOTES AND DETAILS C3.5 DRAINAGE NOTES AND DETAILS C4.1 SEWER AND WATER SERVICE PLAN C4.2 SEWER NOTES AND DETAILS C4.3 WATER NOTES AND DETAILS C5.1 FRONTAGE IMPROVEMENT PLAN AND PROFILE C5.2 FRONTAGE IMPROVEMENT SECTION AND DETAILS - DEFERRED C5.3 PAVEMENT MARKING, LIGHTING NOTES AND DETAILS - DEFERRED SURVEY INFORMATION LEGAL DESCRIPTION THURSTON COUNTY TITLE ESCROW NO. TH8749 LOT 2, BLOCK 9 IN MCKENNA IRRIGATED TRACTS, AS RECORDED IN VOLUME 9 OF PLATS, PAGE 43. VERTICAL DATUM NAVD 88 DATUM BASIS OF BEARING WASHINGTON STATE GRID SOUTH ZONE FROM CTR SEC. 19 (THPN PT#839) TO NE CORNER SECTION 19 (TCHPN APPROVED FOR CONSTRUCTION BY, DATE: _ DRECTOR OF PUBLIC WORKS EXPIRES: 9 F- W W 2 U) Q.' O U W F - z O JOB NUMBER 18025 DRAIANG NAME 18025 CO.1 CVR C0.1 1 OF 15 r HORIZONTAL CONTROL NOTES: OCONSTRUCT DRIVEWAY APRONS TO MATCH EXISTING EDGE OF PAVEMENT. O2 CONSTRUCT NEW ON-SITE CONCRETE SIDEWALK PER DETAIL ON SHEET C1.2. O3 CONSTRUCT NEW PARKING LOT EXTRUDED CURB PER DETAIL ON SHEET C1.2. OSTRIPE NEW PARKING LOT STALLS PER DETAIL ON SHEET C1.2, SO STRIPE NEW ADA PARKING STALLS PER DETAIL ON SHEET C1.2, OINSTALL ACCESS GATE. ONEW PAVING SECTION PER DETAIL ON SHEET C1.2. OCONSTRUCT NEW REFUSE ENCLOSURE STRUCTURE AND CONCRETE PAD PER DETAIL ON SHEET C1.2. O9 NEW LANDSCAPING. I■ 5 I 3 I 3 ■ e9.019.0 R3.0 RI 6*0 PAVING NOTE: ALL PAVING SHALL BE DONE PRIOR TO OCTOBER IST WILL REQUIRE APPROVAL FROM THE OWNER AND PROJECT ENGINEER. SUB—GRADE THAT DOES NOT MEET COMPACTION OR IS SATURATED WILL REQUIRE THE CONTRACTOR TO PROVIDE A WRITTEN 2 YEAR WARRANTY FOR THE PAVING, ADA NOTE: �� ALl NEW SIDEWALKS SHALL NOT EXCEED 2% SIDE SLOPE AND - ADA PARKING STALLS AND RAMP LANDINGS SHALL NOT EXCEED 2 PERCENT SLOPE IN ALL DIRECTIONS, ALL ADA ACCESSIBLE ROUTES IDENTIFIED ON THE PLANS SHALL NOT EXCEED 5% LONGITUDINAL GRADE, ALL ADA RAMPS SHALL NOT EXCEED 8% GRADE AND 2X CROSS SLOPE. CONTRACTOR - IS RESPONSIBLE TO CHECK GRADES PRIOR TO CONCRETE AND \ PANNG WORK. ANY GRADES EXCEEDING THE ABOVE LIMITS WILL BE REQUIRED TO BE CORRECTED AT THE SOLE EXPENSE OF THE CONTRACTOR. -\ R \ 23 1 Gi! � '•R25.0�' S 0 �� .:: •RIB -0:::: .:f3.OJ o �1.0 i :.�;:::::::. '•: -24.0- 'i• 8.0••;::::::: T +::. i e g3:6 2 3 8 j 100.0 t4.0 57.0 STORAGE .- OFFICE a 34.5 I" 31.0 13 .0 sm we _ 5 STORAGE s ` ;I: e e oeeeeee°000e000 3 50.0 SHOP v�'a4' • 80.0 118.0 :G: 1 2.0 i 3 7 3 to/c •: :•: •: •:.: 56.0 J 9.0 _ 120.0 •E 4 7 3 •c..ij1;8QC ti �ti;_G 24.0 3 G .�'• o a 2 • s am am - 4.0 �. 71.0 53.0 : •:• •; :,: •: •: ,.: •:::: •:: •::: • ;� � 44,Q '� .'r is 3 _ .i �a _ _ r _ i :a — — — — — — — I 1 - �R••.0:• �t' B _ Rh _ •t _ _ x Wo III r•.y.... ...�.�.�•^��4.�.��ti V ~; ::7401 7�.D8 PLAT) .31"• — — — — _ �:�• ) : R20'aN ... • E$�:ROW FOR:(�EFERjZFli. FROtl7AGI=-IMP{7jmEAlENT'$: • _ :R:�O.O .0 r f ' CN• ' • CSS -•--- t.'a :�- cr �-- - �4�P ae F �L..' - +:,s.� • - ;� Tt�� r� — ::d,���' ' et '—«–•ca+ :—• :_ GA; .� ck_�_— p{ :--:-: ss• :--•cx[� ; :-:-��' cxc� c F —6+�(29 Gq.�, C k • A • .g ;A � A - . i .--• - .W ._ - - ..W '� iC• • W ' H . �',M . M• .. ;W. , `-. SF. - _ . W - ' _ �-c-. W . W • ; - SY ; :. �'—.W. � Y�. W -N . K b W •W •W W R W W % W W W W •*.• ••W W W' .�• •W ••W •W W W W W W & W I W W W W W W _. 5$ SS SS _5 Q a5 S5 SS B S u S 55 - $ 55 S< 55 SS S NORTHERN PACIFIC RD NW c 0 52' 7.38" E 2531.1cla W- 0 w d z 0 K K K N M mm I�1 m m U 3 c� z J U fY �W�1 Q' Y a Z L� }O F U Z g a J O H Z O U J F Z O N O 2 ww' rsTTst�°��' S/off EAG i Q w_1 Q W ~ a W C a W } � Z rn o oa � - - wonwnmbelaw f NDMYWdlg Joe NUMBER 18025 DRAINNG NAME 18025 C1.1 HCPL C1.1 2 OF 15 f- 2" CSTC 3ASPHALT TOP COURSE L 8" CSBC COMPACTED NATIVE SOIL M ST BE EXCAVATED LEVEL PRIOR TO PLACEMENT OF BASE COURSE. TYPICAL PAVING SEC110N 4" CONCRETE TOP COURSE �—COMPACTED NATIVE SOIL MU 4" CSBC 8E EXCAVATED LEVEL PRIOR TO PLACEMENT OF BASE COURSE. TYPICAL SIDEWALK SECTION INSTALL HANDICAPPED SIGN PER ROW. SEE DETAIL ON THiS SHEET. 2' —TYPICAL VAN ACCESS 4" HIDE WHITE PAINT STALL DNE (TYP,) INTERNATIONAL BLUE DETECTABLE WARNING PATTERN AREA SHALL BE YELLOW, IN COMPLIANCE WITH STD, SPEC, 8-14.3(3) A B RAMP PLAN 'I°I E_EVAnoN 3/I6" MIN. FN HED GRADE I AAAA FACE OF CURB5 0 Mr 11NO 1/2' - 10' 1' 1/2 R. n ', ' 1" R. `TOP 0 ROADWAY 2S' s" —{ 2s0 h ice\ R1.5' n OR PARKING \ LOT 6' L 8" CSBC COMPACTED NATIVE SOIL M ST BE EXCAVATED LEVEL PRIOR TO PLACEMENT OF BASE COURSE. TYPICAL PAVING SEC110N 4" CONCRETE TOP COURSE �—COMPACTED NATIVE SOIL MU 4" CSBC 8E EXCAVATED LEVEL PRIOR TO PLACEMENT OF BASE COURSE. TYPICAL SIDEWALK SECTION INSTALL HANDICAPPED SIGN PER ROW. SEE DETAIL ON THiS SHEET. 2' —TYPICAL VAN ACCESS 4" HIDE WHITE PAINT STALL DNE (TYP,) INTERNATIONAL BLUE DETECTABLE WARNING PATTERN AREA SHALL BE YELLOW, IN COMPLIANCE WITH STD, SPEC, 8-14.3(3) A B RAMP PLAN 'I°I E_EVAnoN 3/I6" NOTES: DETECTABLE WARNING SURFACE 1. THE DETECTABLE WARNING SURFACE (DWS) SHALL EXTEND THE FULL WIDTH OF THE CURB RAMP THE LANDING, 2, (EXCLUSIVE DH DETECTABLEE FLARES) D SURFACE SHALL BE RE RESERVE PLACED AT THE BACK OF CURB, AND NEED NOT pAFp(ING PARICNG FOLLOW THE RADIUS. 3, THE ROWS OF TRUNCATED DOMES SHALL BE ALIGNED TO BE PERPENDICULAR TO GRADE BREAK yAy AT THE BACK OFF CURB. rip 4. THE ROWS OF TRUNCATED DOMES SHALL IBE ALIGNED TO BE PARALLEL TO THE DIRECTION OF IRAOi INSTALL MUTCD SIGN R7 -e IN 5. CURBURB AND GUTTER ARE NOT PRESENT, SUCH FRONT OF HANDICAPPED AS SHARED -USE PATH CONNECTION, THE STALL DETECTABLE WARNING SURFACE SHALL BE PLACED AT THE PAVEMENT EDGE. Q POST REWIREDIN LANDSCAPE AREAS. ADHERE SIDEWALK AND CURB RAMP SIGN ONLY 70SIDING WHEN 6, SEE STANDARD PLANS FOR SIDEWALK AND CURB BUILDING BORDERS SIDEWALK. RAMP DETAILS 7, IF CURB RAMP IS REWIRED, THE LOCATION OF THE DETECTABLE WARNING SURFACE MUST BE AT ��ADA STALL AND ACCESSIBILITY �_J N.T.S. SIGN DETAIL 0.25' 25' ADA SIGN &STALL ADD_SIGN&STALL.dwg 0 2r ---�L5 4' SOLID / STRIPE (T)P) r T I-'Jl WHEEL STOP/PARKING STALL INSTALLATION DETAIL N.T.S. ell o r 4' SOLID STRIPE (TIP) `vl '0. COMPACT WHEEL STOP/PARKING STALL INSTALLATION DETAIL N.T.S. MIN. MAX. FACE OF CURB5 0 1/2' - 10' NOTES: DETECTABLE WARNING SURFACE 1. THE DETECTABLE WARNING SURFACE (DWS) SHALL EXTEND THE FULL WIDTH OF THE CURB RAMP THE LANDING, 2, (EXCLUSIVE DH DETECTABLEE FLARES) D SURFACE SHALL BE RE RESERVE PLACED AT THE BACK OF CURB, AND NEED NOT pAFp(ING PARICNG FOLLOW THE RADIUS. 3, THE ROWS OF TRUNCATED DOMES SHALL BE ALIGNED TO BE PERPENDICULAR TO GRADE BREAK yAy AT THE BACK OFF CURB. rip 4. THE ROWS OF TRUNCATED DOMES SHALL IBE ALIGNED TO BE PARALLEL TO THE DIRECTION OF IRAOi INSTALL MUTCD SIGN R7 -e IN 5. CURBURB AND GUTTER ARE NOT PRESENT, SUCH FRONT OF HANDICAPPED AS SHARED -USE PATH CONNECTION, THE STALL DETECTABLE WARNING SURFACE SHALL BE PLACED AT THE PAVEMENT EDGE. Q POST REWIREDIN LANDSCAPE AREAS. ADHERE SIDEWALK AND CURB RAMP SIGN ONLY 70SIDING WHEN 6, SEE STANDARD PLANS FOR SIDEWALK AND CURB BUILDING BORDERS SIDEWALK. RAMP DETAILS 7, IF CURB RAMP IS REWIRED, THE LOCATION OF THE DETECTABLE WARNING SURFACE MUST BE AT ��ADA STALL AND ACCESSIBILITY �_J N.T.S. SIGN DETAIL 0.25' 25' ADA SIGN &STALL ADD_SIGN&STALL.dwg 0 2r ---�L5 4' SOLID / STRIPE (T)P) r T I-'Jl WHEEL STOP/PARKING STALL INSTALLATION DETAIL N.T.S. ell o r 4' SOLID STRIPE (TIP) `vl '0. COMPACT WHEEL STOP/PARKING STALL INSTALLATION DETAIL N.T.S. 4" CONC. Aim m 2' CLEARANCE (TYP.)- 6 1/2' FACE OF CURB5 0 1/2' - 10' 1' 1/2 R. n ', ' 1" R. `TOP 0 ROADWAY 2S' s" —{ 2s0 h ice\ R1.5' n OR PARKING \ LOT 6' Z )Ri - � •e' ' R1' MIN :/2' CS�7C. EDGE OF ASPHALT BARRIER CURB EXTRUDED CURBING DETAIL 5 1/2" 1.R 1/2"R _j ° 24' 1/2" R g" - J01 T CURB GRADE � ae R24' 0" 4' 1' TO 20' A. 8 1/2" 10' R24' ' e' 1' 6"-� CURB AND GUTTER ROLLED CURB AND GUTTER NOTES: 1. EXPANSION JOINT MATERIAL TO BE 3/8" THICK PREMOLDED JOINT FILLER FULL THICKNESS OF CONCRETE SPACING, 2, FORM AND SUBGRADE INSPECTION REWIRED BEFORE POURING CONCRETE, 3. WHEN CHECKED WITH A 10 FOOT SIHAIGHTEDGE, GRADE SHALL NOT DEVIATE MORE THAN 1/8 INCH, AND AUGNMENT SHALL NOT VARY MORE THAN 1/4 INCH, 1 CONCRETE CURB DETAILS CONC CURB DT N.T.S. CONC_CURB_DT.dwg 4" CONC. Aim m 2' CLEARANCE (TYP.)- 2.5"� 1" I TWO #3 BARS ' • IY • I . 8" MIN, 6" 10" MAX. 3:i SAND & CEMENT - GROUT 1" DEPTH TWO #6 BARS PRECAST CEMENT CONRETE WHEELSTOP N.T.S. SEE BARRIER CURB DETAIL THIS SHEET. � 2" CRUSHED SURFACING TOP COURSE OR WELL GRADED SAND. I 15' VARIES 5' 5' GENERAL NOTES: 1. EXPANSION JOINT MATERIAL TO 8E 3/8" THICK PREMOLDED JOINT FILLER FULL THICKNESS OF CONCRETE. 2. FORM AND SUBGRADE INSPECTION REQUIRED BEFORE POURING CONCRETE, 3. SCORE MARKS SHALL BE t1/8" WIDE BY t1/4" DEEP. FOR SIDEWALKS OVER 8' IN WIDTH, A LONGITUDINAL SCORE MARK SHALL BE MADE ALONG CENTER OF WALK, 4. EXPANSION JOINTS SHALL BE INSTALLED IN CURB AND GUTTER AND IN SIDEWALK AT PC AND PT AT ALL CURB RETURNS, EXPANSION JOINTS SHALL BE PLACED IN SIDEWALK AT SAME LOCATIONS AS THOSE IN CURB AND GUTTER WHEN SIDEWALK IS ADJACENT TO CURB AND GUTTER, UNLESS OTHERWISE DIRECTED BY ENGINEER, ONSITE SIDEWALK DETAIL N.T.S. NON—SHRINK GROUT 0 N s < Z m K K N VI a m m m < U U a 3 Z J U r U W a 0 U J za Ow UQ J Q �a z� oW N F S Z 1Y � W� Tl� 1p17AT, EAG ■L Z �. a d W i a W f � Z ■ W oa O � 1ww,.n,n 6dovt Catl811t� mpum JOB NUMBER 18025 DRAWING NAME 17050)-ICND C1.2 3 OF 15 0 - 2.5"� 1" I TWO #3 BARS ' • IY • I . 8" MIN, 6" 10" MAX. 3:i SAND & CEMENT - GROUT 1" DEPTH TWO #6 BARS PRECAST CEMENT CONRETE WHEELSTOP N.T.S. SEE BARRIER CURB DETAIL THIS SHEET. � 2" CRUSHED SURFACING TOP COURSE OR WELL GRADED SAND. I 15' VARIES 5' 5' GENERAL NOTES: 1. EXPANSION JOINT MATERIAL TO 8E 3/8" THICK PREMOLDED JOINT FILLER FULL THICKNESS OF CONCRETE. 2. FORM AND SUBGRADE INSPECTION REQUIRED BEFORE POURING CONCRETE, 3. SCORE MARKS SHALL BE t1/8" WIDE BY t1/4" DEEP. FOR SIDEWALKS OVER 8' IN WIDTH, A LONGITUDINAL SCORE MARK SHALL BE MADE ALONG CENTER OF WALK, 4. EXPANSION JOINTS SHALL BE INSTALLED IN CURB AND GUTTER AND IN SIDEWALK AT PC AND PT AT ALL CURB RETURNS, EXPANSION JOINTS SHALL BE PLACED IN SIDEWALK AT SAME LOCATIONS AS THOSE IN CURB AND GUTTER WHEN SIDEWALK IS ADJACENT TO CURB AND GUTTER, UNLESS OTHERWISE DIRECTED BY ENGINEER, ONSITE SIDEWALK DETAIL N.T.S. NON—SHRINK GROUT 0 N s < Z m K K N VI a m m m < U U a 3 Z J U r U W a 0 U J za Ow UQ J Q �a z� oW N F S Z 1Y � W� Tl� 1p17AT, EAG ■L Z �. a d W i a W f � Z ■ W oa O � 1ww,.n,n 6dovt Catl811t� mpum JOB NUMBER 18025 DRAWING NAME 17050)-ICND C1.2 3 OF 15 \ v SCALE: 1"=60 FEET 0 30 60 120 sass 333- \ \\ \ \ \ \ \ \\ \ \ \ SF \ \ \ �\ 1p WSDOE BMP LIST - CONTRACTOR SHALL HAVE A COPY OF THE PROJECT \ \'77 SWPPP ONSITE AT ALL TIMES DURING CONSTRUCTION, SEE SWPPP FOR LISTED BMPS. CE CONSTRUCTION ENTRANCE -BMP C105 CONTRACTOR SHALL INSTALL 15 FT WIDE CONSTRUCTION ENTRANCEIEXIT aX s x nr ee USING 4 TO B INCH MINUS QUARRY ROCK 12 INCHES THICK PER WSDOE FIGURE \ \ 114.2.12. CRUSHED CONCRETE WILL NOT BE ALLOWED. PLACE WOVEN \ GEOTEXTILE WITH A GRAB TENSILE STRENGTH OF 200 PSI IF SOFT SOILS ARE ENCOUNTERED. PROVIDE LENGTH PER PLAN. CONTRACTOR SHALL REMOVE X\ ALL SILT FENCING ONCE THE PROJECT IS COMPLETED OR DETERMINED TO BE STABILIZED BYTHE PROJECT ENGINEER. CONCRETE WASHOUT AREA -BMP C154 CONTRACTOR SHALL PROVIDE THE CONCRETE WASHOUT AREA AT THE \ \ LOCATION SHOWN ON THE APPROVED TESC PLANS. CONTRACTOR SHALL USE ONE OF THE TWO OPTIONS SHOWN ON WSOOE FIGURE 114.1.7A. WASHOUT 1 \\ \ \ \ AREA SHALL BE A MINIMUM 10 -FOOT X 1 O -FOOT SQUARE. CONTRACTOR SHALL ti - MAINTAIN THE BMP THROUGHOUT CONSTRUCTION AND REMOVE WASHOUT \Y• \ WATER AS NEEDED DURING THE WINTER MONTHS. CLEAN ALL CONCRETE TOOLS OVER THE WASHOUT AREA. NO WASHOUT AREA WATER MAY ENTER THE GROUND, SURFACE OR ONSITE STORMWATER SYSTEM. IP STORM DRAIN INLET PROTECTION -BMP C220 CONTRACTOR TO PROVIDE INLET PROTECTION ON ALL NEW CATCH BASIN INLETS IMMEDIATELY AFTER INSTALLATION. ALL EXISTING CATCH BASINS WITHIN 500 FEET OF THE SITE CONSTRUCTION ENTRANCE SHALL ALSO RECEIVE INLET PROTECTION. SEE DETAIL ON APPROVED PLANS. REMOVE THE BMFS ONCE THE SITE IS DETERMINED TO BE STABILIZED BY THE PROJECT ENGINEER. SF SILT FENCING -BMP C233 CONTRACTOR SHALL INSTALL ALL SILT FENCING PER APPROVED TESC PLAN AND WSDOE FIGURE 114.2.12. SILT FENCING ALONG THE CLEARING LIMITS SHALL BE ORANGE IN COLOR. SEE PROJECT SWPPP FOR SILT FENCING SPECIFICATIONS. WO WATTLES-BMPC235 CONTRACTOR SHALL PROVIDE WATTLES PER APPROVED TESC PLAN AND WSOOE FIGURE 114.2.14. \\\ \ \ IP} 0 N S 0 O Z �m 0 m m Z zz w G N 3 c� z J r U W � J 0 a Z ly O U 0 Z a�Z o� Uo oF- Z W � U z Z O W D_ 2 clW W In r IONA�j.E A���4 W $ •wLw,, Q � F 3 m C a W f Z • • C7 ? 3 w m � W D a Gall 811Selorey"udig JOB NUMBER 18025 DRAHING NAME 18025_C2.1—ECPL C2.1 4 OF 15 wireto If konc!Zrd Typical V—Shaped Channel Cross—Section REPLACEMENT, AND NOT TO SCALE THESE ESC FACILITIES IS stoples, wire rings � RESPONSIBILITY OF THE CONTRACTOR ach to equivalent to attach fabric equivalent to ALL CONSTRUCTION to po2N27 by 14 Go, wire or AND APPROVED 1000 m1n, •SII` I✓`I�Y �����i•I •i •.•-���I�p, Si'� •Ir.Mlninnur� 6t maxtrenchPost Install driveway culvert if there Is a roadside ditch 40 — B" .� present .� quarry spalls Geotextile •�-����� •1;:1�1•'I�I�I� .;I Notes: 15- min, 1. Driveway shall 12* thicknei meet the minimum requirements of the permitting agencyo Provide full width of 2. It is recommended ingress/egress that the entrance area be cromed so that runoff drains Base Flow Figure �172'x2' wood posts.steel Stabilized Construction fence posts, or NOT TO SCALEcouivolentpop Figure II -4.2.1 EntranceDEPARTMENT Typical Grass—Lined Channels OF O EPARTMENT OF Revised June 2015 ECOLOGY -State Pleaseses ht1p4/Avivivecywo.gov1bopyTigUMrn1 for copyright notice including frame Type "Above Grade" with Wood Planks of Washingtor tn: imitation of liabiirly, end disda&Iwr. 3 4 I r1 Straw rolls must be placed along . VAd acnt rolls slope contours \ shall tightly 441 Y N 10' – 25' (3-8n) Spacing depends on soli type and slope Sediment. organic steepness matter, and native j seeds are captured behind the rolls. • – 5• (75-125mm) B• – 10• Dia. \js� •...:. f y \; (200-250mm) Live Stoke 1• xxi• StakAl� //I�'4 (25 25mm) NOTE: t 1. Straw roll installation requires the placement and r secure staking of the roll in a trench, 3• – 5• (75-125mm) deep, dug on contour. Runoff must NOT TO SCALE Figure ales .14 Wattles DEPARTMENT OF Revised November 2015 ECOLOGY Fleaseseahaµ/Mww.ecyora.govhapyrighthbnfwcopytightmaecab ladmgpwAssiana, Slate of Washingtonimitation of iabiily, and disclaimer. Typical V—Shaped Channel Cross—Section REPLACEMENT, AND be spliced at posts. Use be sli"ced at as is" Us THESE ESC FACILITIES IS stoples, wire rings � RESPONSIBILITY OF THE CONTRACTOR ach to equivalent to attach fabric equivalent to ALL CONSTRUCTION to po2N27 by 14 Go, wire or AND APPROVED e equiwlent. if standard qu'vorp •SII` I✓`I�Y �����i•I •i •.•-���I�p, Si'� •Ir.Mlninnur� 6t maxtrenchPost With Rock Center for spacing may be .00�increased 2"x2* wood posts.backing to 8' If wire is used steel force posts, "equivalentequivalent. �/ l Ytfth J Fabric Filter Fabric if standardstrength fabric used 6 ilter Fit ter fa r; fabric 2' min Backfill trench with native soR Owrcut channel 2• (50mm) washed gravel Minimum 4= x4ptrench Base Flow �172'x2' wood posts.steel fence posts, or NOT TO SCALEcouivolentpop Figure II -4.2.1 10 mil plastic Typical Grass—Lined Channels Two lining O EPARTMENT OF Revised June 2015 ECOLOGY peas& see hffp7Asww."cywagovicnpyy htrW far copyright notice including peardssions, frame Type "Above Grade" with Wood Planks slate of Washinglo imitation of liabiirly, end disda&Iwr. Figure II -4.1.7a I at. Concrete Washout Area DEPARTMENT O Revised June 2015 3 4 I r1 Straw rolls must be placed along . VAd acnt rolls slope contours \ shall tightly 441 Y N 10' – 25' (3-8n) Spacing depends on soli type and slope Sediment. organic steepness matter, and native j seeds are captured behind the rolls. • – 5• (75-125mm) B• – 10• Dia. \js� •...:. f y \; (200-250mm) Live Stoke 1• xxi• StakAl� //I�'4 (25 25mm) NOTE: t 1. Straw roll installation requires the placement and r secure staking of the roll in a trench, 3• – 5• (75-125mm) deep, dug on contour. Runoff must NOT TO SCALE Figure ales .14 Wattles DEPARTMENT OF Revised November 2015 ECOLOGY Fleaseseahaµ/Mww.ecyora.govhapyrighthbnfwcopytightmaecab ladmgpwAssiana, Slate of Washingtonimitation of iabiily, and disclaimer. Typical V—Shaped Channel Cross—Section REPLACEMENT, AND With THESE ESC FACILITIES IS Rack \� Center RESPONSIBILITY OF THE CONTRACTOR 6 go ALL CONSTRUCTION \ / 150-225mm) ~ \\� Key in AND APPROVED Crass–tined,���\\' Fabric Filter Fabric ypical Parabolic Channel Cross—Section With Rock Center for Base Flo Plan lining Nates: (150-225mmin) �/ l Ytfth J Fabric Filter Fabric Channel l tnar Typical Trapezoidal Channel Cross—Section Design \/ Depth B B iur fastened Owrcut channel 2• (50mm) to allow bulking during \ Y seedbed preparation and Waith Rack growth of vegetation. Filter Fabric Center for Base Flow NOT TO SCALE a is Section B•B Figure II -4.2.1 10 mil plastic Typical Grass—Lined Channels Two lining O EPARTMENT OF Revised June 2015 ECOLOGY peas& see hffp7Asww."cywagovicnpyy htrW far copyright notice including peardssions, frame Type "Above Grade" with Wood Planks slate of Washinglo imitation of liabiirly, end disda&Iwr. Figure II -4.1.7a 3 4 I r1 Straw rolls must be placed along . VAd acnt rolls slope contours \ shall tightly 441 Y N 10' – 25' (3-8n) Spacing depends on soli type and slope Sediment. organic steepness matter, and native j seeds are captured behind the rolls. • – 5• (75-125mm) B• – 10• Dia. \js� •...:. f y \; (200-250mm) Live Stoke 1• xxi• StakAl� //I�'4 (25 25mm) NOTE: t 1. Straw roll installation requires the placement and r secure staking of the roll in a trench, 3• – 5• (75-125mm) deep, dug on contour. Runoff must NOT TO SCALE Figure ales .14 Wattles DEPARTMENT OF Revised November 2015 ECOLOGY Fleaseseahaµ/Mww.ecyora.govhapyrighthbnfwcopytightmaecab ladmgpwAssiana, Slate of Washingtonimitation of iabiily, and disclaimer. TE 0411% a • 1PERFECT FIT) /—RETRIEVAL 48" STRAP 36 a•i:�I •:i•.�w.v� c� =♦tom .y., •e�I:l�`I\-s �jf yO1♦i I`�♦!illi. - � �.♦a•Ipj s. p9i ti ti ei oil•-'- �Ve1♦OIl���l�•iNNe). .♦� DISCHARGEr,♦♦ei ♦? .e4i ♦?i >,�qG..e♦ivyPEAK • STORM yr^w ECITE LBRIC at1oii:ci•'eei ::'•eel eie1. (CONTRACTOR • INSPECT AND CLEAN A MINIMUM OF BASINY TWO WEEKS.)CATCH PROTECTION DETAIL TEMPORARY EROSION AND SEDIMENTATION CONTROL STANDARD NOTES: THIS PROJECT DOES NOT REQUIRE A NPDES CONSTRUCTION STORMWATER PERMIT FROM WSDOE, APPROVAL OF THIS EROSION/SEDIMENTATION CONTROL (TESC) PLAN DOES NOT CONSTITUTE AN APPROVAL OF PERMANENT ROAD OR DRAINAGE DESIGN (E.G. SIZE AND LOCATION OF ROADS, PIPES, RESTRICTORS, CHANNELS, RETENTION FACILITIES, UTILITIES), THE IMPLEMENTATION OF THESE TESC PLANS AND THE CONSTRUCTION, 3m Minimum REPLACEMENT, AND Lath and THESE ESC FACILITIES IS OO O flagging n 3 RESPONSIBILITY OF THE CONTRACTOR UNTIL ALL CONSTRUCTION Berm Sandbag AND APPROVED 10 mil plastic lining varies O A O A 0 1m Der m Q O O 0 Section A•A 70 mil plastic Plan lining Nates: 1. Actual layout determined In the Type "Below Grade" field. 2. A concrete washout sign shall 3m Minimu be installed within 10 m of the temporary a Is concrete washout Wood rlity. B B iur fastened vaus Stake (typ.) a is Section B•B 10 mil plastic Two lining 2x12 Plan rough frame Type "Above Grade" with Wood Planks NOT TO SCALE Figure II -4.1.7a Concrete Washout Area DEPARTMENT O Revised June 2015 ECOLOG Please see hdpA%vwwecywe.go�yrlghthtWfor copyright notice Induding permissions, stab of Washinglor imitation of liability, and disdaimer. TE 0411% a • 1PERFECT FIT) /—RETRIEVAL 48" STRAP 36 a•i:�I •:i•.�w.v� c� =♦tom .y., •e�I:l�`I\-s �jf yO1♦i I`�♦!illi. - � �.♦a•Ipj s. p9i ti ti ei oil•-'- �Ve1♦OIl���l�•iNNe). .♦� DISCHARGEr,♦♦ei ♦? .e4i ♦?i >,�qG..e♦ivyPEAK • STORM yr^w ECITE LBRIC at1oii:ci•'eei ::'•eel eie1. (CONTRACTOR • INSPECT AND CLEAN A MINIMUM OF BASINY TWO WEEKS.)CATCH PROTECTION DETAIL TEMPORARY EROSION AND SEDIMENTATION CONTROL STANDARD NOTES: THIS PROJECT DOES NOT REQUIRE A NPDES CONSTRUCTION STORMWATER PERMIT FROM WSDOE, APPROVAL OF THIS EROSION/SEDIMENTATION CONTROL (TESC) PLAN DOES NOT CONSTITUTE AN APPROVAL OF PERMANENT ROAD OR DRAINAGE DESIGN (E.G. SIZE AND LOCATION OF ROADS, PIPES, RESTRICTORS, CHANNELS, RETENTION FACILITIES, UTILITIES), THE IMPLEMENTATION OF THESE TESC PLANS AND THE CONSTRUCTION, MAINTENANCE, REPLACEMENT, AND UPGRADING OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF THE CONTRACTOR UNTIL ALL CONSTRUCTION IS COMPLETED AND APPROVED AND VEGETATION/LANDSCAPING IS ESTABLISHED. THE BOUNDARIES OF THE CLEARING LIMITS SHOWN ON THIS PLAN SHALL BE CLEARLY FLAGGED IN THE FIELD PRIOR TO CONSTRUCTION, DURING CONSTRUCTION THE PERIOD, NO DISTURBANCE BEYOND THE FLAGGED CLEARING LIMITS SHALL BE PERMITTED, THE FLAGGING SHALL BE MAINTAINED BY THE CONTRACTOR FOR THE DURATION OF CONSTRUCTION, THE TESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED IN CONJUNCTION WITH ALL CLEARING AND GRADING ACTIVITIES, AND IN SUCH A MANNER TO ENSURE THAT SEDIMENT AND SEDIMENT LADEN WATER DO NOT ENTER THE DRAINAGE SYSTEM, ROADWAYS, OR VIOLATE APPLICABLE WATER STANDARDS, THE TESC FACILITI ES SHOWN ON THIS PLAN ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS, DURING THE CONSTRUCTION PERIOD, THESE TESC FACILITIES SHALL BE UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS AND TO ENSURE THAT SEDIMENT AND SEDIMENT—LADEN WATER DO NOT LEAVE THE SITE. THE TESC FACILITIES SHALL BE INSPECTED DAILY BY THE CONTRACTORS CESCL AND MAINTAINED AS NECESSARY TO ENSURE THEIR CONTINUED FUNCTIONING TO MAINTAIN DISCHARGE WATER QUALITY. THE ESC FACILITI ES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH OR WITHIN THE 48 HOURS FOLLOWING A MAJOR STORM EVENT, AT NO TIME SHALL MORE THAN ONE F00T OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A TRAPPED CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT LADEN WATER INTO THE DOWNSTREAM SYSTEM. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES MAY BE REQUIRED TO INSURE THAT ALL PAVED AREAS ARE KEPT CLEAN FOR THE DURATION OF THE PROJECT. T.E.S.C. BMP CONSTRUCTION SEQUENCE: BEFORE ANY SITE GRADING ACTINTIES BEGIN: 1. INSTALL ORANGE PERIMETER SILT FENCES. 2.CONSIRUCT STABILIZED CONSTRUCTION ENTRANCE AND EXITS. 3.DESIGNATE UMITS OF PROTECTED PERVIOUS ASPHALT AREA. 4. REQUEST SITE INSPECTION BY THURSTON COUNTY, AFTER ONSITE GRADING BEGINS: 5.COVER OR MULCH ONSITE TEMPORARY SOIL STOCKPILES, 6.PROVIDE TEMPRORARY AND PERMANENT SEEDING AS NEEDED. 7.INSTALL UNDERGROUND UTILITES, B.INSTALL ROOF DRAINS AND LEADERS TO PERVIOUS ASPHALT SECTION, 9.INSTALL NEW PARKING LOT BARRIER CURBING AND ONSITE SIDEWALKS. 10. INSTALL ONSITE LANDSCAPING AND IRRIGATION AROUND BUILDING PER APPROVED PLANS. 11. EXCAVATE AND PREPARE PERVIOUS ASPHALT STRUCTURAL SECTION AND ROOF DRAIN PERF. SYSTEM, 12. FINAL GRADE AND PAVE ACCESS ROAD AND PARKING AREAS N1TH PERVIOUS ASPHALT, 13. DO NOT STOCKPILE LANDSCAPE MATERIALS ON PERVIOUS ASPHALT UNLESS IMPERMEABLE LINER IS USED, 14. REMOVE ALL TEMPRORY CONTROL BMPS, 15. MONITOR STABILIZED AREAS UNTIL FINAL STABILIZATION. ZLL OO to m m � m Z m 3 V cl o v o y 3 (9 Z J U } U w � .�Jj Q' r a Z L� }O F- U J J � Q Z W O zz O Q O W wO Z 570\�W4 T � � i�i�•irr�� � r� C a W � � •• o d � i Iwwwbm bel ow. i CallBtt ftreyoudlit JOB NUMBER 18025 DRANiNG NAME 18025_C2.2�CNO C2.2 5 OF 15 Now / L ((� i Mi l !� I / SEE SHEET C3.2 ' ` �_ �• 1 \ \ n 1 1I sr P I 1( I i / \ \ .\ \ I , f J /. fri \ I - DRAINAGE "V" DITCH / \(/ +3:1 SIDE SLOPES (TYP.): i . - J / , �. Structure Table Structure Table .\ Structure Name Details Structure Name Details CB #1 TYPE 1 RIM = 337.22 N: 7321.92 E:25425.74 INV OUT (N) = 335.40 CB #8 TYPE 1 RIM = 338.94 , N: 7630.38 E: 25748.57 INV IN (S)= 335.83. 3 INV OUT (NE) = 335.83 RIM = 337.53 N:7377.60 RIM 336.37 CB #2 E: 25419.44 N: 7677.62 TYPE 1 INV IN (S)= 335.12 INV IN (NE)= 335.70 CB #9 TYPE 1 E: 25810.07 INV IN (SW)= 334.56 INV OUT (W) = 333.92 INV IN (SE)= 334.56 INV OUT (NE) = 334: 6- RIM = 339.15 CB #3 TYPE 1 N:7409.92 E:25480.80 INV IN (NE)= 336.60 CB #10 TYPE 1 RIM = 336.75 N: 7616.49 E:25868.26 INV IN (SE)= 336.60 INV OUT (NW) = 334.98 INV OUT (SW) = 336.60 RIM = 334.17 . . CB #4 TYPE 1 RIM = 339.25 N: 7370.83 E:25509.00 INV OUT (NW) = 337.13 CB #11 TYPE 1 N: 7748.76 E:25883.11 INV IN (SW)= 332.130 - INV OUT (NW) = 331 97 RIM = 339.60 RIM = 332.96 CB TYPE 1 N:7472.32 E: 25599.27 INV IN (S)= 337.27 12 CB SPILL CON'#fROL M.H. N: 7842.47 E: 25757.71 INV IN (SE)= 330.80' INV OUT (SW) = 337.27 INV OUT (W) = 330.80 CB #6 TYPE 1 RIM = 339.53 N: 7387.45 E:25617.40 CB #13 TYPE 2 BEEHIVE OVERFLOW GRATE RIM = 336.20 N: 7281.22 E: 25439.65 INV OUT (N) = 337.70 j INV OUT (NW) = 333:70 RIM = 338.23 RIM = 333.50 CB #7 N: 7556.84 CB #14 N:7664.56 TYPE 1 E: 25760.50 TYPE 2 BEEHIVE OVERFLOW GRATE E:25928.31 INV OUT (N) = 336.20 INV OUT (NW) = 331 00 \ \ IE 329,50 \ \\ + \ DRAINAGE :1 SIDE SLOPES (TY'P.) \ SCALE: 1'=30 FEET 129' 12"0 HDPE ® 1.01% 0 15 30 60 FG 333.37 \ 1 . \ ) A FG 335.98 � e SST \ \ \ \ tiGe J iIt a CB #12 ell loss\ \ t ul?o \ � FG 334.42 I` e m � FG 336,22 , V nm y 5n�l C3.4 !�"' h"' n .? \ (oMATCHf EX. I ( I E 333.82. ( (: .. .. - . .. r�'ry w 1 "0,50%.i \ \ \ _ 335 i 20' 12"s HDPE �I / - _ _ _ C, / _ _ - 78' 8"0 HDPE ®1.64% ` 69' 8"0 HDPE Pipe ® 1.30% ! - - \ t I CB #2 - . .-' _ 134' 8"0 _H/DPE ®0.50% - - CB #8 \ \ CB #9 , 8„g H\E ®2.22% ----- - ------ ------ ---- --- --- - _ �. -- C # FG 341 20 102• B 11 FG 337.61 ' \ \ V f IF I �• CB #3 I FG 340.81 ` �L ! \ `56' 8"9 HDPE 0 0.50% e , ,i I ` \ , FG 337.88 ! e FG 338.91 FG 336.271 ` , FG 339,67 74' 8" P HDPE ® 0.50% jJ FGI 337.88 ! FG 339.26 FG 340.30 CB 5 e FG 338.56 \ \ FG 335.07 \ I 1 FG 339.30 I # I , �. ` i 11 i ::1k - . t X/ ; / • ...I' :: as e o y \ J��\ e , -� ....... \ \ ` FG 335.36 / I 1 \ _..L \ I FG. 336.87 N - , • - FG 339.50 48. 8"6 HDPE Pipe ®_1.10% a Md' d. - e s �`F6• ; • \\\ ;.w'•:: '••;CB 1••°Il e10 / M 'Til 9 •;;�C::::::.: 1 x • • F - , O ,5 , •,• , oa FG 335.78 io MATCH EX. ( I _ _ 'l\ 26' LONG x 4' WIDE x 3' DEEP 4 r FG 339.92 / 1 _ { m • • INFILTRATION TRENCH .C3.4 i FG 340.15 \ ! j ® �?' ' � .. ` `zv 336,16I� DEFFltRm FG 338.54 OFFICE , , O FG 4 28' LONG x 4' WIDE x 3' DEEP J F.F. 339.5 FG 341.58 e C3.4 FG 337.22 \ OFFICE S e i " DO NOT INFILTRATION TRENCH , 1 M FG 335.68 \ CONSTRUCT 1 i ( I ( (I 1I % I F.F. 340.5 STORAGE 1 M .�.�a ::�►-87� 8"0 HDPE Pipe ®0.50% ; ::: - B 7 F.F. 339.0 14' 6"0 PVC ®0.00% \ I�0 DEFERRm 10' 6"0 PVC 0 0.00% ' :: 1 CB f r # DO NOT I �J ,� i n FG 340.04 • �;; FG 340.400 e e e e e e FG 34L51 CB\ 10 �\ F.F.H337.0 // CB #14 d 5., CONSTRUCT 9 o I o FG 341.73 , I ' 91 }l 4 • ( l CB #13 I J o .- ; ; FG 340.75 FG 341.57 �/ # o r ;l:; FG 340.43 o n FG 341.65_ ✓ ; • ;�;::: _ FG 337.45/ ( FG 341.21 G 3 FG 340.35 F 40.45 FG 3 40.06 t� / / FG 341.85\Jl ::C-:-�:•:•: ::[_•'kkao4a•:'::• :I •'::::.6, -,a:.:::::•. e YY Iw i •'v: l: _ o _ M _s w "%7: .t;' ;1. i �c -&-ff - 6 own_ FFG 340. 2' �'�-T��" 7 wow owns owol FG 337. 5 Gr 4 r _ _ • F 340.91 ,. �: Z5 j : r 1 'i: :' =i a �• y - = - ::i ,;',. _ ��==i X7.44. .li0 ' 4� • • csl own don quo won dominommi� k �111 To w • p..r.'u;a' .r. • •C=;•--. t?; •dw :, �: `� c--aE ;-r.--- C v _ . •w- • *, w .w • n. y .'w .. _ • P • ' - w A, w-�•'•_.•w .w•�-v: k'.� ;y+. w=w-A - w w --y -•w_• w w w--v��-w�•z w. -•w- ,w ••� w 'www ww- _MATCH EX._ - - - r+ _ - -i ----- ------- -MATCH EX.------ =.t3g _- -�f - _s ss s 9 mss ss ss ss x340 Ss ss a 55 55 341- -341 ---� ss ss ss n5 Ss c - e Ss V ss ss s_< - _ c NORTHERN PACIFIC RD NW - - - c spO s5 3Sw -------- -- ---- - =� \--------- ---------------------f�----- s---- -------_ - _ -- �-- -- 52' 2531.14 0 0 N 5 z V 'a a N M 2 II o m 3 z J L) a z O Z g IL W Q QZ Q ❑ Z Q C7 Z STec�°1��r IGNdI,1%tlA m ee eL z �. w, Q W � w C a W } � zm .. � d 3 rn o a . W eowwfiu.betam youing JOB NUMBER 18025 DRAVANG NAME 18025_3.1_GDPL C3.1 6 OF 15 SCALE: i'=30 FEET 0 15 30 60 500' LONG x 3.9' WIDE INFlLTRATION CELL BOTTOM ELEV. = 327.5 1 � 947 64 •55Y E / \\\ i p 5 � � # � / / 333 / / � � � �• ��' � _ -'. O 21 WIDE EMERGENCY OVERFLOW- / ELEVATION = 330.5 '/- / C3.4 / / / / / 330• 33� 3.2 3 3 .. - .. � / ,a.% ' — � �- 2 331_ 543' LONG x 6.5 WIDE /. Oi33� 33 / / f _ s /J. / / �: 9 /BIORETENTION CELL 31330 J - BOTTOM ELEV. = 329.5 C3.3 / Qg4op�\.G ryO�OF yrcj / / / / / / / .21 ' WIDE INTERNAL SPILLWAY 2 O Oi / / / - / . ELEVATION = 330.5 C3.4�- / FOSggcx\ / // / / f 332 DRAINAGE "V" DITCH 3:1 SIDE SLOPES (TYPJ — / —ter J' I " . - \m \ " m I - y m�� rT- GRAVE RD -STORAGE AREA -smT -T P4"SOD AND FINE I. GRADE DD. CSBC. AS NEEDED.N m \ L4 m—__ _ - - - .532' LONG x 4.6' WIDE \ 332 _ .520' LONG. x 8' WIDE e .'_� _ - _ L / INFILTRATION CELL BRIORETENTION CEL.3 '— y ` : _ - ��� - - '� `a- - -BOTTOM ELEV. 327.0 21 ' VA INTERNAL SPILLWAY- _ I BOTTOM ELEV. 329.0 — — — — .. RAINAGE "V' DITCH - .1 ` — - - : - _ N - - — �" 1 SIDE E —m. - - - ELEVATION 330 0 - - C3.4 - �: �\ 3: SLOPS (T1P.) -- - 330 331= --��- 331- - oil330— • — _— 7855 E— 327 328 329 Ell 3s 33s 33i. -333- _ � --- 328 327 + � � i N-• lco,�,,�;r )t ' J PPR WCONSVR-ff i6tFf�%O 330 329 ` •� - r { 33e 335_ 5 34 to 55" E 1245.18 CALC (1245.99 PLAT / Z I /� / 33s 33 — — _ -11111b. —( �/_--�\� �� l f I \ /!_ _• �c�, i / I \ �/ a ! I3\—dxG a;o _.��'—ate PROVAL El@IREI: 0 N w C5 m. m m p K K K N M m II it w��, 3 C7 Z J U U W � J a z � 0 U Z �gZ � W Q 0 �o ro z a SIG SCE.t"'G�ry .L Q g � W 4 � Z u (7 d 3 V1 m � Lu oa � �n belovz Call BR neImpuay JOB NUMBER 18025 DRAWING NAME 18025 3.2 GDPL C3.2 7 OF 15 OVERFLOW RISER WITH SEDIMENT CONTROL STRUCTURE PER DETAIL THIS SHEET BOTTOM INFILTRATION FG = 331.45 4' WIDE x 3' DEEP x 28' LONG INFILTRATION TRENCH PER DETAIL 4 ON SHEET C3.4 BIORETENTION W/ INFILTRATION TRENCH SECTION N. OVERFLOW RISER WITH SEDIMENT CONTROL STRUCTURE PER DETAIL THIS SHEET BOTTOM INFILTRATION FG = 329.75 GRAVEL YARD TS 4' WIDE x 3' DEEP x 26' LONG INFILTRATION TRENCH PER DETAIL 4 ON SHEET C3.4 BIORETENTION FG = 39' LONG x 3' MADE BIORETENTION CELL PER DETAIL THIS SHEET 27' LONG x 4' NIDE BIORETENTION CELL PER DETAIL THIS SHEET BIORETENTION W/ INFILTRATION TRENCH SECTION 520' LONG x 8' WIDE BIORETENTION CELL PER DETAIL THIS SHEET N.1:S BIORETENTION SOIL 500' LONG x 3.9' NIDE INFILTRATION CELL 3WIDE BERMS ELEV. = 331.0 WO ELEV. 100 YR ELEV. = 330.0 = = 330.5 s ELEV. = 327.5 �I/ PER 3.9' 21.1' 6.5' A GRAVEL YARD ION FG = 329.5 543' LONG x 6.5' WIDE BIORETENTION CELL DETAIL THIS SHEET BIORETENTION W/ INFILTRATION CELL SECTION N. TS 3'COARSE COMPOST IN PONDING AREA NATIVE SUBGRADE, 00 NOT COMPACT NATIVE MATERIAL UNDER BIO -RETENTION CELL. BIORETENTION PLANTING NOTES ALL BIORETENTION AREAS SHALL BE SEEDED BY AN APPROVED HYDROSEEDER WHICH UTILIZES WATER AS THE CARRYING AGENT, AND MAINTAINS CONTINUOUS AGITATION THROUGH PADDLE BLADES, BIORETENTION SOIL MIX NOTES: 1. BIORETENTION MIX SHALL MEET THE DEFAULT BIORETENTION SOIL MIXAS DETERMINED IN THE D.O.E STORMWATER MANAGEMENT MANUAL UNDER VOLUME 5 PG. 7-18. ALTERNATIVE: CUSTOM BIORETENTION MIX MAY BE ACCEPTED IF TESTED TO MEET REQUIREMENTS IN THE O.O.E. STORMWATER MANAGEMENT MANUAL AND APPROVED BY THE CITY OF YELM. IT SHALL HAVE AN OPERATING CAPACITY SUFFICIENT TO AGITATE, SUSPEND, AND MIX INTO A HOMOGENEOUS SLURRY THE SPECIFIED AMOUNT OF SEED, WATER, FERTILIZER AND MULCH. GRASS SEED ALL GRASS MIXTURES SHALL CONTAIN FRESH, CLEAN, NEW CROP SEED. SEED IS TO BE MIXED MECHANICALLY ON THE SITE, OR MAY BE MIXED BY THE DEALER. IF SEED IS MUCED ONSITE, EACH VARIETY SHALL BE DELIVERED IN THE ORIGINAL CONTAINERS BEARING THE DEALER'S GUARANTEED ANALYSIS. IF SEED IS MIXED BY THE DEALER, THE CONTRACTOR SHALL FURNISH TO THE LANDSCAPE ARCHITECT THE DEALER'S GUARANTEED STATEMENT OF THE COMPOSITION OF THE MIXTURE AND THE PERCENTAGE OF PURITY AND GERMINATION OF EACH VARIETY. W GRASS SEED SHALL BE PURCHASED FROM A RECOGNIZED DISTRIBUTOR AND SHALL BE COMPOSED OF THE FOLLOWING VARIETIES MIXED IN THE PROPORTIONS INDICATED. SEED SHALL MEET THE MINIMUM PERCENTAGES OF PURITY AND GERMINATION SPECIFIED. SEED'A' THROUGH 'H' SHALL 17 BE APPLIED AT THE RATE OF 240 POUNDS PER ACRE, UNLESS OTHERWISE SPECIFIED BELOW ON THE APPROVED PROJECT PLANS. la WATER THE CONTRACTOR IS RESPONSIBLE FOR ENSURING A WELL-ESTABLISHED STAND OF GRASS, R WATERING IS SUGGESTED AT LEAST TWICE A WEEK DURING THE GROWING SEASON AND AS NEEDED AFTERWARDS. —. VEJG WHENGRASS IS REQUIRED AS A BEST MANAGEMENT PRACTICE ON STEEP SLOPES, NON -GERMINATED SEEDS SHALL BE KEPT MOIST, AND ROOTED GRASS SHALL HAVE AT LEAST 1 INCH OF WATER PER MONTH DURING THE PERIOD FROM MAY 15 THROUGH SEPTEMBER 15. WQ ELEV. 330.0 YR ELEV.L=33/0,0 FERTILIZER 10' FERTILIZER SHALL BEA COMMERCIAL MIX WITH A 16-14-8 FORMULA, INCLUDING 50 PERCENT SLOW RELEASE NITROGEN, OR THAT MIX AS RECOMMENDED BY THE SEED SUPPLIER AND APPROVED FOR USE BY THE LANDSCAPE ARCHITECT. GRASS MIXES USED SHALL MEET THE FOLL ELEV. = 327.0 20' 532' LONG x 4.6' WIDE INFILTRATION CELL BIORETENTION W/ INFILTRATION CELL SECTION OWING SPECIFICATIONS: % BY WEIGHT BIORETENTION GRASS: FESTUCA ARUNDINACEA/TALL FESCUE 33% HYDROSEED FESTUCA RUBRA/RED FESCUE 33%HYDROSEED LOLIUM PERENNE /PERENNIAL RYEGRASS 33% HYDROSEED 5 BIORETENTION CELL �T 0 rn 5 0 0 z m N to m r m m z K S < U U a (7 Z J U } U W � � J a Z L� }O F U J_ Q F W ❑ Z Q BOTTOM INFILTRATION FG = 329.75 GRAVEL YARD TS 4' WIDE x 3' DEEP x 26' LONG INFILTRATION TRENCH PER DETAIL 4 ON SHEET C3.4 BIORETENTION FG = 39' LONG x 3' MADE BIORETENTION CELL PER DETAIL THIS SHEET 27' LONG x 4' NIDE BIORETENTION CELL PER DETAIL THIS SHEET BIORETENTION W/ INFILTRATION TRENCH SECTION 520' LONG x 8' WIDE BIORETENTION CELL PER DETAIL THIS SHEET N.1:S BIORETENTION SOIL 500' LONG x 3.9' NIDE INFILTRATION CELL 3WIDE BERMS ELEV. = 331.0 WO ELEV. 100 YR ELEV. = 330.0 = = 330.5 s ELEV. = 327.5 �I/ PER 3.9' 21.1' 6.5' A GRAVEL YARD ION FG = 329.5 543' LONG x 6.5' WIDE BIORETENTION CELL DETAIL THIS SHEET BIORETENTION W/ INFILTRATION CELL SECTION N. TS 3'COARSE COMPOST IN PONDING AREA NATIVE SUBGRADE, 00 NOT COMPACT NATIVE MATERIAL UNDER BIO -RETENTION CELL. BIORETENTION PLANTING NOTES ALL BIORETENTION AREAS SHALL BE SEEDED BY AN APPROVED HYDROSEEDER WHICH UTILIZES WATER AS THE CARRYING AGENT, AND MAINTAINS CONTINUOUS AGITATION THROUGH PADDLE BLADES, BIORETENTION SOIL MIX NOTES: 1. BIORETENTION MIX SHALL MEET THE DEFAULT BIORETENTION SOIL MIXAS DETERMINED IN THE D.O.E STORMWATER MANAGEMENT MANUAL UNDER VOLUME 5 PG. 7-18. ALTERNATIVE: CUSTOM BIORETENTION MIX MAY BE ACCEPTED IF TESTED TO MEET REQUIREMENTS IN THE O.O.E. STORMWATER MANAGEMENT MANUAL AND APPROVED BY THE CITY OF YELM. IT SHALL HAVE AN OPERATING CAPACITY SUFFICIENT TO AGITATE, SUSPEND, AND MIX INTO A HOMOGENEOUS SLURRY THE SPECIFIED AMOUNT OF SEED, WATER, FERTILIZER AND MULCH. GRASS SEED ALL GRASS MIXTURES SHALL CONTAIN FRESH, CLEAN, NEW CROP SEED. SEED IS TO BE MIXED MECHANICALLY ON THE SITE, OR MAY BE MIXED BY THE DEALER. IF SEED IS MUCED ONSITE, EACH VARIETY SHALL BE DELIVERED IN THE ORIGINAL CONTAINERS BEARING THE DEALER'S GUARANTEED ANALYSIS. IF SEED IS MIXED BY THE DEALER, THE CONTRACTOR SHALL FURNISH TO THE LANDSCAPE ARCHITECT THE DEALER'S GUARANTEED STATEMENT OF THE COMPOSITION OF THE MIXTURE AND THE PERCENTAGE OF PURITY AND GERMINATION OF EACH VARIETY. W GRASS SEED SHALL BE PURCHASED FROM A RECOGNIZED DISTRIBUTOR AND SHALL BE COMPOSED OF THE FOLLOWING VARIETIES MIXED IN THE PROPORTIONS INDICATED. SEED SHALL MEET THE MINIMUM PERCENTAGES OF PURITY AND GERMINATION SPECIFIED. SEED'A' THROUGH 'H' SHALL 17 BE APPLIED AT THE RATE OF 240 POUNDS PER ACRE, UNLESS OTHERWISE SPECIFIED BELOW ON THE APPROVED PROJECT PLANS. la WATER THE CONTRACTOR IS RESPONSIBLE FOR ENSURING A WELL-ESTABLISHED STAND OF GRASS, R WATERING IS SUGGESTED AT LEAST TWICE A WEEK DURING THE GROWING SEASON AND AS NEEDED AFTERWARDS. —. VEJG WHENGRASS IS REQUIRED AS A BEST MANAGEMENT PRACTICE ON STEEP SLOPES, NON -GERMINATED SEEDS SHALL BE KEPT MOIST, AND ROOTED GRASS SHALL HAVE AT LEAST 1 INCH OF WATER PER MONTH DURING THE PERIOD FROM MAY 15 THROUGH SEPTEMBER 15. WQ ELEV. 330.0 YR ELEV.L=33/0,0 FERTILIZER 10' FERTILIZER SHALL BEA COMMERCIAL MIX WITH A 16-14-8 FORMULA, INCLUDING 50 PERCENT SLOW RELEASE NITROGEN, OR THAT MIX AS RECOMMENDED BY THE SEED SUPPLIER AND APPROVED FOR USE BY THE LANDSCAPE ARCHITECT. GRASS MIXES USED SHALL MEET THE FOLL ELEV. = 327.0 20' 532' LONG x 4.6' WIDE INFILTRATION CELL BIORETENTION W/ INFILTRATION CELL SECTION OWING SPECIFICATIONS: % BY WEIGHT BIORETENTION GRASS: FESTUCA ARUNDINACEA/TALL FESCUE 33% HYDROSEED FESTUCA RUBRA/RED FESCUE 33%HYDROSEED LOLIUM PERENNE /PERENNIAL RYEGRASS 33% HYDROSEED 5 BIORETENTION CELL 0 rn 5 0 0 z m N to m r m m z K S < U U a (7 Z J U } U W � � J a Z L� }O F U J_ Q F W ❑ Z Q W F O Z W Q Z_ Q a' SlONO`��7 Q Q F W �C a W � � Z ■ Al � oa ' ' x w.nmhd■W canenbdae,md JOB NUMBER 18025 ORAVANG NAME 18025_C3.3_GDND C3.3 8 OF 15 ROCK PROTECTION INTERNAL SPILLWAY NUI I U SUALC 6' x 78' DEEP CONCRETE ANTI -SEEP COLLAR I-�1 8`J: AT SPILLWAY WATER BOTTOM OF :E BIO -RETENTION POND ELEV: 329.0 NOTE: PROVIDE QUARRY SPALLS FOR ROCK PROTECTION WSDOT SPEC 9-13.1. REASONABLY WELL GRADED, MAX. STONE SIZE 12', MEDIAN STONE SIZE 80. MIN. STONE SIZE 2' ROCK PROTECTION INTERNAL SPILLWAY NU 1 1 U .II,ALC ���y\may\y\��\�y\�\ � " • • - • • 6' x 1 B' DEEP CONCRETE ANTI -SEEP COLLAR TATER BOTTOM OF 3 BIO -RETENTION POND � rr ELEV: 329.5 I� NOTE: PROVIDE OUARRY SPALLS FOR ROCK PROTECTION WSDOT SPEC 9-13.1. REASONABLY WELL GRADED, MAX. STONE SIZE 12', MEDIAN STONE SIZE 8', MIN. STONE SIZE 2' ROCK PROTECTION EMERGENCY OVERFLOW NOT TO SCALE NOTE: PROVIDE QUARRY SPALLS FOR ROCK PROTECTION WSDOT SPEC 9-13.1. REABONABLY WELL GRADED, MAX. STONE SIZE 12', MEDIAN STONE SIZE S', MIN. STONE SIZE 2• 9't AT SPILLWAY 3 ,1 1' ROCK PROTECTION BOTTOM INFILTRATION POND 327.5 IEPARATION GEOTEXEILE FABRIC SECTION AA 1 SECTION AA yV NOTE: EXI5TIY0 116'NATNE RAC;6ILL _ 1Vi2 GROUNb ELEV- - Ft` FG C�N!;RF'F i,t10FR'fL.IN FIPC MECTI!iC+ �PECIFI�A I IONS CI fAai EK ri JS.Z jzl }IAS' FiF OR TOPSOIL F O. Vr1TH TH'r AOGITIO\'•t CO\DITIONS fir\ \`�. \��\f�ti '— V 1, T11E PtGttl Cori AT10N55NALL DE CIRCULAR A,1'OA Fl_TE SRIC FAIN1kU`A OF K"GAN!EIEIi �' � = R 'F 2. THEY EINLL UE CLEANLY GUT ANO BE Sb10L1TH � UND ANO Dl`IFORM V.Tfti NO FXCFS-4 CO`Jr,RETE LEFT a - FROFI THE HOLE PERTORt.TiONS PROCESS. 4 't = Di 1 ELEV. 3. THERE SHhLL DE A MINLSR;I.t (.� 7 SEi5 GF ti i.I PERFORATIONS V,'ITt12 HOLES FER SET OF 1- PERFGRATIONS FOR L1H:11'f.5 OF PIPE LEf.Gil 1. SOTTOAi E.EV= 4 RUBBER GASNFTS OR GROt,TIAC. OF THF JOIVi$ _'�1-. tis=i;:-_ FOR P�RFORATEG PJPE RUN$5:•ILL NOT 6E FEIiFO1L}TFO WtHI REOUWEG. FERFORAilGN - t;5-- ;^ NUY F£UICTUREO 5. INSPECTION OF THE PERFORATEG COFA:t�TE (1n0:NWARO O! ION GRAIN ROCK EOUN. TO 19PE EIl4LL DE IAAUE UY tHE MUNIi:nAUT}• 4`iS00T SPEC. P -03.12j5) DEFOTtE INSTALLATION Oi THE PSL IV THE TRENCH SECTION GRIXItiTJ. INFILTRATION TRENCH NUI I U JUALt 2' • • • • • • • • • • • • • • • • • PLAN 1'ABOVE CROWN EXISTING ANDIOR �Up1p PROPOSED GROUND OUTF RIPRAP 24' MIN. J NON -WOVEN GEOTEXTILE FABRIC RIPRAP NOTE: MIRAFI 140N ORAPPROVED EQUIVALENT MAXIMUM STONE SIZE: 24 INCHES (NOMINAL DIAMETER) MEDIAN STONE SIZE: 161NCHES SECTION MINIMUM STONE SRE:4INCHES OUTFALL PROTECTION NOT TO SCALE ANa CGFtn fL=34296 2B- MAX. a RISER OR ADJUSTMENT 10 a SECTION FLAT SLAB COLER 48", 54" OR 60" srfPs oR 12" uDnER r• MORTAR SAND COLLARS (�•) (PVC PIPE (NtLY) N07ES 1. Nondholds in riser section oradjust- e menf section steal/ hava 3• min. dear- - once. Steps in catch basin shall hove B� min. clearance. No steps ora required f1=3.30.80 when 9� is 4• or less. 2. Precast bases shall hove cutouts w knockouts with a wall thickness of 2 - min.. Nde sizes shall be equal to pipe outw d/ometer plus catch basin oral/ thickness. Connections to catch basin to be mode with sand collar w equiwlent. Maximum hde size !s 35- for a 48- rntch basin, 42• !or 0 54- catch basin, and 48� for o 50• cntdi basin. Minimum distance between hdes is 8' 3, AI/ base reinforcing sled shalt be j4 rebar on B" center spacing, placed in fha top half of the base, 1' m/n. clearance 2 1/2� max. Neorance. 4. The bottom oI the precast catch basin may be rounded. 5. Frame and grata may be (nstolled with Range down or cost into risen MORTAR FlLLET 54.0=8• 60.0=8- SEPARATE CAST IN PLACE j4 REBAR (77P) OFt SEPARATE PRECAST BASE. -O• R/NG " FOR SEPARATE ' CAST IN PLACE GRAVEL BACKFlLL FOR PIPE e BEDDING, 6- MIN. COMPACTED �.���bE ✓0/VFQEFAL DEPTH. FOR PRECASTED BASES ONLY. TYPE 2 CATCH BASIN #12 -SPILL CONTROL co NO I I U SCALE S 0 z Q7 N Vl m ~ 'm z i 8 Q 3 z J V � g a Z UEs� O U W Q J Z_ a W O ❑ Z Z as � W Z F• O � Z (7 K ,•W�p 70NALEK�'lr- Q L � � W W f Z ■• � d3 � m � •vxwnmbeiovc • CJLIIB11ne1orelollm JOB NUMBER 78025 DRASNNG NAME 18025 C3.4 GOND C3.4 9 OF 15 �1 Pre s ° Ilse ng ?ell b I / TYPE 1 CATCH BASIN & RISER - H-20 LOADING - Ma da manta ASTM C476 and // a WSOOT/APWA Slmdard SpedRcaUms �-10 . r ' / '•r. r. rr. u./Ir iOamvr RISER 2"aw 60 bs 4' Om 160 ba 6w = 240 be lY = 460 be 2r 90 be (r/ Ie' r; TYPE 1 CATCH BASIN 2.100 ba r/ 204 KNOCKOUTS 11PICAL ALL (4) SALES AVAILABLE OPTQNS- CA VAI B FOPTQNS- CA GS AVABABIE WSDOT SPA B-5.20.01 A.s Tea.sexvnaram OmzAvaara 161 01110Y2016 OdeeM RruL fic aBlAddress ,- AL WA B✓b 2 1 / O�IdI)b(I I 9aBT1 hone: 1 \\\ ({\\ 48" TYPE 2 CATCH BASIN - Hs -20 1Metl eta s ASsru C478 k¢ - Yadrse mTe ma al ws5or/APwA stmao<d sp.alnmelm. - Rubbc goaket )+Int w4 I ASIY C41.T - Ptllpropllms awoo and to mbl most TW 04101 - flefi/orcemmt woo meats minimum A Cm. /0.20�Irementm In., Flot Top = 0.15 h'/IMaar 1L F bpN dHcibna, r/ 0.20 fi.' O 90' aomd apenfiq in9 bars lab), 0.15 t job requkunenta wsoor s1ro a-19.29-01 FOR DETAMSr SEE RGVERS�a A. s.q arco�ura ! mrs 166 MOWIBlll� •YELM DEPT,• ORKS TYPICAL PIPE ■ TRENCH APPROVED CITY ENGINEER DATE mmm ' ' RESTORATION TABLE 1 SURFACE THICKNESS BACKFlLL/ COMMENTS/ TYPE fANPAC110N REONNiS WHEN REWIRENFNTS CRUSHED 4" CRUSHED SURFACE SELECT BAC!(FlLL FlNISH MADE SHALL BE SURFACE TOP COVRSE COMPACT TO 95x SYDDTN A CONSISTANT WITH EXISTING 3"IAN. GRADE B A.C. MSH ROADWAY TO A.C. PAVORENT PAYING OVER {" CRUSHEDSURFACETOPSELECT BACKFlLL CONFORM TO ALL E]OSTW OVER GRAVEL BASE SURFACE COURSE COMPACT TO 95x GRADES AND CURBS SLOPES SHALL MATCH CONCRETE SURFACE HATCH flOS11NC SELECT BACKFlLL MATCH EXISTING MSH CONCRETE THICKNESS COMPACT TO 95i TE%1VRE. AND GRADE HYDROSEED/ PIANTNGS FlNISH GRADE SHALL BE LAWN/LANOSCAPE OVER 4" MW, TWE A NAPVE BACKF91 SMOOTH @ CONSISTANT TOP SOB. COMPACT TO &5i W1TH EXISTING0.IGRADE NATIVE BACKFBACKFILCITYLMWNO BACKfi1 UNPROVm SUFACE N/A COMPACT TO B51 2" ABOVE E%ISIWG WADE a suoonl ®Idcasth Precast' FRAME ANO COVER zro Im RA1lCE DOAK UP Delivering Reliability 48" TYPE 2 CATCH BASIN GRADE RING 2 On 60 ba TYPE 1 CATCH 4" On 120 Ibs BASIN RISER 8' Onb 160 ba 6" = 240 ba 12'=4B016e y_\ _ _10' ,4', V. 12'a 24" 4 4 4B`FLAT TOP 1WTx z4'r 46'FLAT TOP / HIXE WIIH 20" z 24' 1,660 be HOLE 1,fi30 15v 11 VIN e' W$DDT SPR B-10.20-01 opanburn.com 154.1 0 s z Q1 KI �I N V1 1F U) Z m Y e ZZY e m 3 w O U C N Q 3 C9 z J i - U W � J a Z (y 0 U W N Z Q W Q Z ,Zr ,Q Q V Z W t� Z 2� tp Cal�yr� ~ a C a W } � Z ■A � d 3 w oa 0 r I�w,.nae 6elrna 6 Ca08Nhe1RreTo9al J08 NUMBER 18025 DRAKING NAME 18025 C3.5_GDND C3.5 10 OF 15 ®Idcasth Precast' FRAME ANO COVER zro Im RA1lCE DOAK UP Delivering Reliability 48" TYPE 2 CATCH BASIN GRADE RING 2 On 60 ba TYPE 1 CATCH 4" On 120 Ibs BASIN RISER 8' Onb 160 ba 6" = 240 ba 12'=4B016e y_\ _ _10' ,4', V. 12'a 24" 4 4 4B`FLAT TOP 1WTx z4'r 46'FLAT TOP / HIXE WIIH 20" z 24' 1,660 be HOLE 1,fi30 15v 11 VIN e' W$DDT SPR B-10.20-01 opanburn.com 154.1 0 s z Q1 KI �I N V1 1F U) Z m Y e ZZY e m 3 w O U C N Q 3 C9 z J i - U W � J a Z (y 0 U W N Z Q W Q Z ,Zr ,Q Q V Z W t� Z 2� tp Cal�yr� ~ a C a W } � Z ■A � d 3 w oa 0 r I�w,.nae 6elrna 6 Ca08Nhe1RreTo9al J08 NUMBER 18025 DRAKING NAME 18025 C3.5_GDND C3.5 10 OF 15 c ( I )t X SCALE: 1'=30 FEET 3 0 15 30 60 (( I J s0 - �; as 1 l 1o �j Qs ; 4 -� 4 OFFICE '• -• ���� STORAGE '�1 e eeee Tl— ............. SHOPo/95T f I i- l �. _ _ z' T Y -� •F. ^�-'''• -. r-s�� - :: J40. R ' 4 .G8 PLAT _ �' an•=. -.=v= ;--�e+�• - - , a•• .'.w - -: sa• �.�y . --- : �. �•k - ; FP.' .P' `� — • tr wv' —�+.y --c ....... ... ..... .... .... ....•.Y » w W w w W w w x' w——w—W — W— w—_w w W w — W--- W---w---p--- y --- R SS ss ss —�- ss. ss ss s ss n n n s r ss u c 55 NORTHERN PACIFIC RD NW c c N 9 1 0 WATER AND SEWER NOTES: (DCONTRACTOR TO COORDINATE WITH CITY OF YELM PRIOR TO PROVIDING SEWER SERVICE TAP. OINSTALL NEW 1 INCH STEP SERVICE LINE AND CONNECTION PER DETAIL 7-2 ON SHEET C4.3. O3 INSTALL NEW1500 GALLON STEP TANK PER DETAIL ON SHEET C4.2. PROVIDE DUPLEX PUMPING SYSTEM PER CITY OF YELM STANDARDS. OCONNECT GRAVITY SEWER FROM NEW BUILDING TO TANK PER DETAIL 7-7 ON SHEET C4.2. OCONTRACTOR TO COORDINATE WITH CITY OF YELM PRIOR TO PROVIDING WATER SERVICE TAP. OINSTALL NEW WATER SERVICE LINE AND METER PER DETAIL 6-1 ON SHEET C4.3. OINSTALL 1 INCH REDUCED PRESSURE BACKFLOW ASSEMBLY IN ABOVE GROUND HOT BOX. OB PROVIDE 1 INCH CL200 PE WATER MAIN SERVICE PIPE TO NEW BUILDING. m• N p � II a : 3 c� Z J U v W IaJ1 IL } A Z LL }O F -- U Z 5 a W F a 0 z a w W 1n IM W " 8 C Q .L Z. Cor ~ C a W # g .. 2 �3 ■ w m o a :; helm • c■nenn�.,w. JOB NUMBER 18025 DRANING NAME 18025_C4.1-SWPL C4.1 11 OF 15 F47n��1 '�II�III■ nuuxl USE i' UNION TAAH NNECT TESTING ASSEMBLY AS SET OFF APARA7U5 FORSURE TESTING SERV FIBERGLASS UD 400 72' YAT71 STEEL BOLTS 43' 550 AND NEOPRENE GASKET ORIFICE 200 MIN RISER TYPICAL MEN PERIMEIER OF VAULT 620 ALL NON-TRAFARING TANKS 1' DIAPVC HOSE AND 600 GAL VALVE ASSEMBLY ORFIGE IIV-2FLETE SUFFICIENT ORIENT BALL VALVE TO ALLOW FOR AS SHOWN. BALL VALVE REMOVAL SMALL BE WITH 12' BELOW ELECTRICAL SPLICE BI CORD GRIPS UD ALL CONNECTIONS SHWRAPPED WITHHEAT SHRINK TAPE 210 OR 24' PVC 24w 30' DIA RIBBED PVC RISER SLOPE GROUND FROM RISER / RISER M7TH NEOPRENE 1) GROMMETS 14 CADGE 6' FROM TOP OR TO CIB' ? 3 VOLUME INSULATED OF ELECTRICAL ITTONING FROM TOP RISER TO WIRE VARIES EFFLUENT DISCHARGE 3Y CONDUIT SEA Yt INSG�WINE - INSTALL Po�INSTALLL�N n .. a rJ F47n��1 '�II�III■ nuuxl 7500 GAL ASSEMBLY AS SET OFF D-1 2 BY qTY OF YEW 400 72' i -I/4' DIA. INLET 43' 550 HOLES AROUND ORIFICE 500 PERIMEIER OF VAULT 620 V-1 APVC 600 GAL 4' DIA PVC FLOW ORFIGE IIV-2FLETE 2400 GAL INDUCER SIORIBE THE MATERIAL FOR DUPLEX, TRIPLEX, AHO 41155 1 DINSON 1 S O�POOMIII CABLE AND TENT INTENT OF F TH WILL VARY. THE CONTRACTOR SHALL MEET THE I/e' BY-PASS GRIFlCE INOTHE INSTALLATION REQUIREMENTS SHOWN IN THE IN THE DISCHARGE HEAD TYPICAL STEP INSTALLATION, CITY OF YELM DEPT. OF PUBLIC WORKS TYPICAL SIMPLEX STEP TANK INSTALLATION APPROVED DWG, NO, GTY ENGINEER DATE 7_9 DES. OWTI. CKD. DALE PMX TE MTO 4/11/00 FIBERGLASS UD WITH STAINLESS STEEL BOLTS AND NEOPRENE GASKET 5' MIN TYP, 10±1/4' ALL LIDS 2' MIN FINISH GRADE TYP. SLOPE TO NARVE GRADE NATIVE i 14 GAUGE COPPER GRADE m TONING WIRE, 2'-W OREPVC RISER, TAIL ABOVE GROUND CO SYSTEMS, INC.v O ` INC., OR EQUAL N L ONQ1C0 TANK TO RISER ADAPTOR (FOR USE WITH NON -TRAFFIC BEARING TANKS) NOTE: RISER AND LID SHALL BE 240 ON ALL SIMPLEX PUMP VAULT INSTALLATIONS. RISER AND LID SHALL BE 300 ON ALL DUPLEX AND TRIPLEX PUMP VAULT INSTALLATIONS. CITY OF YELM DEPT. OF PUBLIC WORKS TYPICAL RISER APPROVED DWG, N0, PUBLIC WORKS DIRECTOR DATE 7-18 DES. I OWN.CKD. DATE JEG PMX PMX MTO 4/11/00 21'0 MIN.PVC RISER WATH WATER TIGHT 14 GAUGE TONING WIRE TO 55 CO--\ I GRADE f WATER TIGHT LID PUMP VAULT RISER 14 GAUGE TONING I�WIRE TO SERVICE N I BOX NOTES: 1. DELETE BAFFLE FON A 3000 GALLON TANK UTILIZED AS A TRIPLEX PUMP VAULT, 2. THE OWNER WALL RENEW TOLERANCES IN EXCESS OF DIMENSIONS SHOWN. 3. THE TRIPLEX PUMP VAULT REWIRES TWO VAULTS AND TWO COMPLETE RISERS, ONE VAULT CONTAINS FLOATS AND ONE PUMP, THE SECOND VAULT CONTAINS TWO PUMPS. 4. 4500 GALLON TANKS OR LARGER SHALL HAVE THREE RISERS AND LIDS. I _ ` 2 PART USE ORCNO TANK TO RISER ADAPTER FOR CONCRETE TANKS PUMP ASSEMBLY, SEE DWG. NO. 7-9 (.1u�•m 1500, 3000, 4500 GALLON STEP TANK/PUMP TANK APPROVED DWG. NO. PUBLIC WORKS DIRECTOR DATE 7-11 DES. OWN. CKO, DATE PMX PMX MTO 1 4/11/00 TABLE 1SEE SPEGFlCARONS FOR ADDITIONAL INFORMATION), 7500 GAL 3000 GAL 7 D-1 2 V-1 72' 72' D-2 2 43' 550 550 D-3 2 500 620 620 V-1 400 GAL 600 GAL V-2 ORFIGE IIV-2FLETE 2400 GAL t400 1) ? 3 VOLUME 1/3 VOLUME _ 60 MIN BEDDING VARIES NOTES: 1. DELETE BAFFLE FON A 3000 GALLON TANK UTILIZED AS A TRIPLEX PUMP VAULT, 2. THE OWNER WALL RENEW TOLERANCES IN EXCESS OF DIMENSIONS SHOWN. 3. THE TRIPLEX PUMP VAULT REWIRES TWO VAULTS AND TWO COMPLETE RISERS, ONE VAULT CONTAINS FLOATS AND ONE PUMP, THE SECOND VAULT CONTAINS TWO PUMPS. 4. 4500 GALLON TANKS OR LARGER SHALL HAVE THREE RISERS AND LIDS. I _ ` 2 PART USE ORCNO TANK TO RISER ADAPTER FOR CONCRETE TANKS PUMP ASSEMBLY, SEE DWG. NO. 7-9 (.1u�•m 1500, 3000, 4500 GALLON STEP TANK/PUMP TANK APPROVED DWG. NO. PUBLIC WORKS DIRECTOR DATE 7-11 DES. OWN. CKO, DATE PMX PMX MTO 1 4/11/00 TABLE 1SEE SPEGFlCARONS FOR ADDITIONAL INFORMATION), 7500 GAL 3000 GAL 4500 GAL D-1 2 60' 72' 72' D-2 2 43' 550 550 D-3 2 500 620 620 V-1 400 GAL 600 GAL V-2 1100 GAL 2400 GAL NOTES: 1. DELETE BAFFLE FON A 3000 GALLON TANK UTILIZED AS A TRIPLEX PUMP VAULT, 2. THE OWNER WALL RENEW TOLERANCES IN EXCESS OF DIMENSIONS SHOWN. 3. THE TRIPLEX PUMP VAULT REWIRES TWO VAULTS AND TWO COMPLETE RISERS, ONE VAULT CONTAINS FLOATS AND ONE PUMP, THE SECOND VAULT CONTAINS TWO PUMPS. 4. 4500 GALLON TANKS OR LARGER SHALL HAVE THREE RISERS AND LIDS. I _ ` 2 PART USE ORCNO TANK TO RISER ADAPTER FOR CONCRETE TANKS PUMP ASSEMBLY, SEE DWG. NO. 7-9 (.1u�•m 1500, 3000, 4500 GALLON STEP TANK/PUMP TANK APPROVED DWG. NO. PUBLIC WORKS DIRECTOR DATE 7-11 DES. OWN. CKO, DATE PMX PMX MTO 1 4/11/00 TABLE 1SEE SPEGFlCARONS FOR ADDITIONAL INFORMATION), FOR FEEDER WIRE RUN WRE S2E MAXIMUM DISTANCE AWG COPPER 150 FEET j10 AWG COPPER 250 FEET d8 AWG COPPER 350 FEET DECAL -SEE SPEGFICARONS BOL018PT. PJSE lfali. LETTERNG Fax seaw� cau �4o-ue-au1 aTYa YFIu I LPADLOCK WITH GONION NEY ON FURNISHED BY THE Cl OF YELM ALARM T SILENCE BUTTON FROM POWER � TO STEP TANK - SIMPLEX SCURCE /'2'C. 13—j72 70 STEP TA71K -DUPLEX 1'c C, 17-112 TO STEP TANK - TRIPLEX NOTE: PANEL 92E MAY VARY DEPENDLNC ON MANUFAWRER TYPICAL PUMP CONTROL PANEL APPRO DWG. N0. \ WORKS � PUBLIC RKS DIRECTOR DAT7_6= 0 S D . DALE JY JEG TP 4/2007 FINISHED 30'f RIS ALARM HIGH LEVEL LAG ON/OFF (4.5' DRAWDOWN ON TO OFF) 6. LEAD ON/OFF DRAWDOWN ON TO OFF) LOW LEVEL ALARM 60 REDUNDANT OFF A 25' 6' MIN. BEDDING m C•l� FLOAT SETTING VAULT DIMENSIONS FOR A DUPLEX PUMP VAULT APPROVED DWG, N0, PUBLIC WORKS DIRECTOR DATE 7-14 DES. OWN, CKD, DATE PMX PMX MTO 4/11/00 EocE aF 2' WATER ncHr HOUSE Cx� TYPICAL IN PROIECTEO AREAS NON -PROTECTED AREAS (LAWNS, ETC.) 2'-0' TAIL REWIRE SERVICE BOXES (CARSON OR RICH) ABOVE I� �.. GROUND 1 EXISTING GROUND 14 GA. COPPER TONING PARE WRAP ONCE AROUND CLEANWi :TANDPIPE NEW 40 PVC SEWER TOP OF STEP TANK PVC C.O. LINE (TTP) (3034) TEST TEE 2.S SLOPE TO TANK T F—I�INLET BAFFLE FERNCO COUPLING OR APPROVED EWAL FERNCO COUPLING ON APPROVED EW AL CITY OF YELM DEPT. OF PUBLIC WORKS TYPICAL CONNECTION APPROVED DWG, NO, GTY ENGINEER DATE 7-7 DES. OWN. C D. DATE PMX PMX MTO 4/11/00 O S it D z m 0' N V) W t - m � Z i m O, W mmz 3 U 3 Z J (.i } V W a 2 Li O U Fn J_ Q W Z Q W F O z W W O D.' yep S/ONA�T•� G1��2• Q a W } Zo. m3 � W oa O ' NrowxxhatY dPJOVA ' foMymdig JOB NUMBER 18025 DRAWING NAME 18025_C4.2_SWND C4.2 12 OF 15 " (OR APPROVED EQUAL) ENVIRONME MIDSTATES, BCF -1416 12RL CONCRETE SIDEWALK 1" PLASTIC LINE (USE 200 PSI -1 DR7 PHILLIPS DRISCO PIPE 5100 POLYETHYLENE PIPE) VALVE BOX OR 4' DIA. PVC RISER, SEE NOTE BELOW. VALVE BOX FOR SIDEWALK OR TRAFFIC SETTINGS, SEE DWG, NO, 6-12 USE 4' DIA, SCHEDULE 40 PVC WITH CAP FOR OTHER INSTALLATIONS. 14 GAUGE INSULATED COPPER TONING WIRE WRAPPED AROUND THE PIPE (SEE GENERAL NOTES NO. 7)— FORD 861-444-G, GRIP P21/= JOINT BY AP THREADS / I' MALE ADAPTER — 3/4" X i• X 12" BELL - REDUCER. �- 1•x 10 FORD GRIP JOINT CORPORATION STOP TWE FB 1101 SERVICE SADDLE NOTES: 1, STAINLESS STEEL INSERTS REQUIRED FOR ALL PACK JOINTS 2, ALL SERVICE SADDLES SHALL AND FITTINGS SHALL HAVE I.P. THREADS CONCRETE DRIVEWAY & OTHER EARTH METER CHECK VALVE 19 1/2' VC CAP SERIES 36 CONCRETE SERVICE SADDLE BACKFILL/ OR ROMAC 202S OR FOG 711E B9H COMPACTION REQMNTS. ROCKWELL 313 METER z SERIES 36 CAST IRON CONCRETE TRAFFIC COVER OR rc FOG THE 89H 7'x 1' FORD GRIP JOINT 'CARSON *CARSON CORPORATION STOP TYPE 3 PLASTIC FB 1101 FINISH ROADWAY TO A.C. PAVEMENT PAVING OVER 4 CRUSHED 1" PLASTIC LINE (USE 200 PSI -1 DR7 PHILLIPS DRISCO PIPE 5100 POLYETHYLENE PIPE) VALVE BOX OR 4' DIA. PVC RISER, SEE NOTE BELOW. VALVE BOX FOR SIDEWALK OR TRAFFIC SETTINGS, SEE DWG, NO, 6-12 USE 4' DIA, SCHEDULE 40 PVC WITH CAP FOR OTHER INSTALLATIONS. 14 GAUGE INSULATED COPPER TONING WIRE WRAPPED AROUND THE PIPE (SEE GENERAL NOTES NO. 7)— FORD 861-444-G, GRIP P21/= JOINT BY AP THREADS / I' MALE ADAPTER — 3/4" X i• X 12" BELL - REDUCER. �- 1•x 10 FORD GRIP JOINT CORPORATION STOP TWE FB 1101 SERVICE SADDLE NOTES: 1, STAINLESS STEEL INSERTS REQUIRED FOR ALL PACK JOINTS 2, ALL SERVICE SADDLES SHALL AND FITTINGS SHALL HAVE I.P. THREADS CONCRETE DRIVEWAY & OTHER EARTH METER CHECK VALVE 19 1/2' VC CAP SERIES 36 CONCRETE CONCRETE BACKFILL/ OR TYPE FOG 711E B9H COMPACTION REQMNTS. *BROOKS CRUSHED SERIES 36 CAST IRON CONCRETE TRAFFIC COVER OR COMPACT TO 95% FOG THE 89H 6. 'CARSON *CARSON STIES 1419-8 PLASTIC 1419 PLASTIC READER UD FORD WM 72-15W 5/8'x 3/4' COPPER METER SETTER 747H CHECK VALVE AND UNION NUT AND SWIVEL FOR CONNECTING 1" IRON PIPE 5/8" SINGLE METER SERVICE APPROVED DWOI NO. PUBLIC WORKS DIRECTOR DATE 6-1 DEB, Dow CmDALE TEW TEW DLM 3/15/01 SERVICE BOX - CARSON INDUSTRIES MODEL N0, 14198 WITH BOLTED HINGED COVER OR EQUAL COVER MARKING TO READ •SEWER• SPLICE TO EXISTING (USE IN NON -TRAFFIC AREAS) WI GAUGE TONING WIRE WITH BUTT 14 GA. INSULTED COPPER TONING HIRE CONNECTORS AND SPLICE TONING WIRE FOR SERVICE TO HEAT SHRINK TAPE FINISH MAINUNE TONING WIRE AND WRAP GRADE-\,/JISPUCE WITH HEAT SHRINK TAPE EXISTING PVC SWIR CONNECT TOMIN. EXISTING PVC 1' SCHEDULE SERVICE LINE 40 PVC SOUP 2" x 1' REDUCERJ PVC SWING CHECK 7 IF REQUIRED VALVE SL x SL 1' BALL VALVE, SL x SL J Y BALL VALVE, SL x SL 1' PVC NIPPLE, SL x SL - x MAIN DIA. PVC REDUCING TEE SL SL TH OR PIPE SADDLE — CITY OF YELM TYPICAL 1" SERVICE CONNECTION APPROVED DW -G, N0, 7 PUBLIC WORKS DIRECTOR DATE / - 2 DES, OWN. CKD, DATE PMX PMX MTO 4/11/00 191 2' METER BOX 7 14" VALVE BOX OR 4" 1 DIA, PVC RISER SINGLE METER 12" MAX, BOX PLACEMENT 2K SLOPE TO BOX to 12" VALVE BOX FOR SIDEWALK OR TRAFFIC SETTINGS, SEE DWG. N0. 6-12 1 1" USE 4' DIA. SCHEDULE 40 PVC 12" p, WITH CAP FOR OTHER INSTALLATIONS* I METER BOX 4" DIA. PVC R DUAL METER v� BOX PLACEMENT 2X SLOPE TO BOX 1 e• V " " 1.200psI W 4" DIA, SCHEDULE 40 PVC- - 12' P.E. PIPE 'oma j ao RESTORATION SURFACE SEE RESTORATION TABLE TYPICAL METER PLACEMENT ATPR01'® DWQ NO. PUBLIC WORKS DIRECTOR DATE 6 — 6 D� DML clm. DATE TEW TEW FEW 3/15/0 SEE RESTORATION FINISH GR BACKFILL SEE RESTORATION TABLE MAINTAIN SIDE SLOPE AS STEEP AS POSSIBLE +Y9557fImvRIa PIPE BEDDING FOR PIPE O.D. W=10 PRESSURE 24' GRAVITY RESTORATION TABLE 1 SURFACE THICKNESS BACKFILL/ COMMENTS/ TYPE 90' BEND COMPACTION REQMNTS. ORION REQUIREMENTS CRUSHED 4" CRUSHED SURFACE SELECT BACKFILL FINISH GRADE SHALL BE SURFACE TOP COARSE COMPACT TO 95% SMOOTH & CONSSTANT 6. 6' NIN. MIN EXISTING 7, Y MIN, GRADE 8 AC. FINISH ROADWAY TO A.C. PAVEMENT PAVING OVER 4 CRUSHED SELECT BACKFILL CONFORM TO ALL EASING OVER GRAVER. BASESVSE �p COURSE COMPACT TO 95% GRADES AND CURBS IO.PLUGS IN TEST COCKS SLOPES SHALL MATCH CONCRETE SURFACE MATCH EXISTING SELECT BACKFILL MATCH E%ISTWG FRUST (DRVEM'AY/SDLT/ U CONCRETE THICKNESS COMPACT TO 95% TEXTURE AND GRADE B. IN OSE ED/ PRANIRIGS NATIVE BACKFILL FINISH GRADE SHALL BE LAYti/LANDSK:APE OVER TI MN. T1PE A SECTION 6.110 5100TH IS CONSISTANT TDP SOILCOMPACT TO &5% YxnH ETIsn6c GRADE NATIVE BACKFILL MOUND BACKFILL UNUMVED SWAM N/A COMPACT TO 65% 2" ABOVE EXISTING I GRADE & SMOOTH CITY OF YELM DEPT, OF PUBLIC WORKS TYPICAL PIPE TRENCH APPROVED DWG. NO. CITY ENGINEER DATE 7-3 DES. DVM.CID. DATE PMX PMX MTO 4/11/00 3 PLASTIC .2 OR CONCRETE BOX n Q 4 g 0 ®1 0 i C4 f7 12" MIN. _.. 6 _r C GRAVEL BASE MATERIAL LIST: 12" THICK 1. SERVK:E LINE 2. 90' BEND 3. UNION 4, NIPPLE 5. SHUT-OFF VALVE 6. 6' NIN. 7, RELIEF VALVE 5. TESTS COCKS 9, DRAIN TO DAYLIGHT IO.PLUGS IN TEST COCKS 01 A. THOROUGHLY FLUSH LINES PRIOR TO INSTALLATION, B. DIAMETER OF PIPE AND FITTINGS = U C. REFER TO DEVELOPMENT GUIDELINES SECTION 6.110 FOR FURTHER INFORMATION, F D. DO NOT INSTALL IN AREA SUBJECT TO FLOODING. _ I 6' YIN. H. g 0 ®1 0 i C4 f7 12" MIN. _.. 6 _r C GRAVEL BASE MATERIAL LIST: 12" THICK 1. SERVK:E LINE 2. 90' BEND 3. UNION 4, NIPPLE 5. SHUT-OFF VALVE 6. CHECK VALVE (D.S,H.S. APPROVED) 7, RELIEF VALVE 5. TESTS COCKS 9, DRAIN TO DAYLIGHT IO.PLUGS IN TEST COCKS GENERAL NOTES: A. THOROUGHLY FLUSH LINES PRIOR TO INSTALLATION, B. DIAMETER OF PIPE AND FITTINGS = U C. REFER TO DEVELOPMENT GUIDELINES SECTION 6.110 FOR FURTHER INFORMATION, F D. DO NOT INSTALL IN AREA SUBJECT TO FLOODING. _ PL 1/4"02%12' HOT DIPPED GALVANIZED FORM CONDUITS TO POST OR CHANNEL SEE TYPICAL PUMP CONTROL O PANEL DETAIL DRAWING f6 r01 PVC ATTACH CONDUIT TO - POST WITH STAINLESS STEEL TWO HOLE STRAPS TO NEW ELECTRICAL PANEL DIRECT BURY CABLE 12" DIA, PLAN 2 PROFILE NIS I) TO BUILDING OR IRRIGATION SYSTEM 1Y OF YELM, WASHINGTON )EPT. OF PUBLIC WORKS REDUCED PRESSURE BACKFLOW ASSEMBLY FOR 2" OR SMALLER DWG, NO. 1 VCRKS DIRECTOR OAr. 6-17 LAWN. CKIX KR cG 7P PUMP CONTROL PANEL 4"x8• PRESSURE TREATED POST 1/4'xYx6" HOT DIPPED GALVANIZED CHANNEL EXISTING GROUND TO STEP TANK DIRECT BURY CABLE CITY OF YELM DEPT. OF PUBLIC WORKS REMOTE POST - RESIDENTIAL PUMP CONTROL PANEL INSTALLATION RIMMKUVIaH PMX I PMX DWG. NO. DATE 7—'t KD. DATE MTO 4/11/00 GENERAL NOTES (WATER MAIN INSTALLATION): 1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH CITY OF YELM STANDARDS AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION. 2, ALL WORK IN CITY RIGHT-OF-WAY REQUIRES A PERMIT FROM THE CITY OF YELM, PRIOR TO ANY WORK COMMENCING, THE GENERAL CONTRACTOR SHALL ARRANGE FOR A PRECONSTRUCTION MEETING TO BE ATTENDED BY ALL MAJOR CONTRACTORS, REPRESENTATIVES OF INVOLVED UTILITIES, AND THE CITY OF YELM, CONTACT THE PUBLIC WORKS DEPARTMENT AT (360) 458-8410 TO SCHEDULE THE MEETING. THE CONTRACTOR IS RESPONSIBLE TO HAVE A SET OF APPROVED PLANS AT THE MEETING, 3, WATER MAINS SHALL MEET THE FOLLOWANG SPECIFICATIONS: POLYVINYL CHLORIDE (PVC) PIPE (UNDER 4 INCHES): PIPE MATERIAL SHALL BE PVC 1120, PVC 1220, OR PVC 2120, AND HAVE MINIMUM WALL THICKNESS EQUAL TO OR LESS THAN THE STANDARD DIMENSION RATIO (SDR) OF 21, AND MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS SECTION 9-30.1(5)B. POLYVINYL CHLORIDE (PVC) PIPE (4 THROUGH 12 INCHES): SHALL MEET THE REQUIREMENTS OF AWWA C900, CLASS 150 WALL THICKNESS EQUAL TO OR GREATER THAN THE SDR OF 18, AND MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS SECTION 9-30.1(5)A, POLYVINYL CHLORIDE (PVC) PIPE (14 THROUGH 20 INCHES): SHALL MEET THE REQUIREMENTS OF AWWA C905 WALL THICKNESS EQUAL TO OR GREATER THAN THE SOR OF 18. DUCTILE IRON PIPE (DIP): DIP SHALL CONFORM TO AWWA C151 CLASS 50 OR GREATER, AND SHALL BE 1/16 -INCH CEMENT LINED AND SEALED IN ACCORDANCE VA - A 1H ANSI AIWA C104 A21.4 90 AND MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS SECTION 9-30.2.(1). SIX-INCH FIRE HYDRANT SPOOLS SHALL BE CLASS 52. 4, GATE VALVES SHALL BE RESILIENT WEDGE, NRS (NON RISING STEM) WITH O -RINGS SEALS. VALVE ENDS SHALL BE MECHANICAL JOINT OR ANSI FLANGES. VALVES SHALL CONFORM TO AWWA 509-80, VALVES SHALL BE MUELLER, M & H, KENNEDY, CLOW R/W OR WATEROUS SERIES 500, EXISTING VALVES TO BE OPERATED BY CITY EMPLOYEES ONLY, 5, HYDRANTS SHALL BE M & H RELIANT STYLE 929, MUELLER CENTURION, OR CLOW MEDALLION OR AVK, HYDRANTS SHALL BE BAGGED UNTIL SYSTEM IS APPROVED. 6. ALL LINES SHALL BE CHLORINATED AND TESTED IN CONFORMANCE WITH THE ABOVE REFERENCED SPECIFICATION (NOTE 1). 6 - 4 4/07 7, ALL PIPE AND SERVICES SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE INSTALLED 12" TO 18" UNDER THE FINAL GROUND SURFACE, THE MARKER SHALL BE PLASTIC NON -BIODEGRADABLE, METAL CORE OR BACKING MARKED WATER 2 -INCH -WIDE MINIMUM, WHICH CAN BE DETECTED BY A STANDARD METAL DETECTOR. TAPE SHALL BE TERRA TAPE "D" OR APPROVED EQUAL. IN ADDITION TO TRACER TAPE, INSTALL 14 GAUGE HEAVY DUTY DIRECT BURY COATED COPPER WIRE (PAIGE "UF" SINGLE CONDUCTOR OR EQUAL), WRAPPED AROUND THE PIPE, BROUGHT UP AND TIED OFF AT VALVE BODY ALL WIRE CONNECTIONS SHALL USE WIRE NUTS AND A DER SPLICE KIT, MANUFACTURED BY 3-M OR APPROVED EQUAL ALL LOCATOR WIRE FOR SERVICE PIPE SHALL BE CONNECTED TO THE LOCATOR WIRE ON THE WATER MAIN. 8, PROVIDE TRAFFIC CONTROL PLN(S) AS REQUIRED IN ACCORDANCE WITH MUTCD, 9, ALL WATER MAINS SHALL BE STAKED FOR GRADES AND ALIGNMENT BY AN ENGINEERING OR SURVEYING FIRM CAPABLE OF PERFORMING SUCH WORK, 10. ALL SERVICE LINE LOCATIONS SHALL BE MARKED ON THE FACE OF THE CURB WITH AN EMBOSSED "Wm 1/4 INCH INTO CONCRETE, 11, CALL UNDERGROUND LOCATE AT 1-800-424-5555 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATIONS, 12, THE CITY WILL BE GIVEN 72 HOURS NOTICE PRIOR TO SCHEDULING A SHUTDOWN. WHERE CONNECTIONS REQUIRE "FIELD VERIFICATION", CONNECTION POINTS WILL BE EXPOSED BY CONTRACTOR AND FITTINGS VERIFIED 48 HOURS PRIOR TO DISTRIBUTING SHUT -DOWN NOTICES. 13. AT ANY CONNECTION TO AN EXISTING UNE WHERE A NEW VALVE IS NOT INSTALLED, THE EXISTING VALVE MUST BE PRESSURE TESTED TO CITY STANDARDS PRIOR TO CONNECTION, IF AN EXISTING VALVE FAILS TO PASS THE TEST, THE CONTRACTOR SHALL MAKE THE NECESSARY PROVISIONS TO TEST THE NEW LINE PRIOR TO CONNECTION TO THE EXISTING SYSTEM OR INSTALL A NEW VALVE. 14, AFTER COMPLETION OF ALL ITEMS SHOWN ON THESE PLANS AND BEFORE ACCEPTANCE OF THE PROJECT, THE CONTRACTOR SHALL OBTAIN A PUNCH LIST'PREPARED BY THE CITYS INSPECTOR DETAILING REMAINING ITEMS OF WORK TO BE COMPLETED. ALL ITEMS OF WORK SHOWN ON THESE PLANS SHALL BE COMPLETED TO THE SATISFACTION OF THE CITY PRIOR TO ACCEPTANCE OF THE WATER SYSTEM AND PROVISION OF WATER SERVICE, 15, A COPY OF THESE APPROVED PLANS AND APPLICABLE CITY DEVELOPER SPECIFICATIONS AND DETAILS SHALL BE ONSITE DURING CONSTRUCTION, 16. ANY REVISIONS MADE TO THESE PLANS MUST BE REVIEWED BY THE DEVELOPERS ENGINEER AND THE CITY OF YELM PRIOR TO ANY IMPLEMENTATION IN THE FIELD, THE CITY SHALL NOT BE RESPONSIBLE FOR ANY ERRORS AND/OR OMISSIONS ON THESE PLANS, O S Iz In UT In N ~ m Z m Go 4�1 << � W U Q U U N 3 0 z J } U Q' : a r z L. O U B' KA W J F W Ll z G Z Z Q Q U) W Lu F- Q FIN �z 0 Q' !G� NOV��a• W a C Q eL Z ._ 0/F� F 0: C IL W � � Z ■• 2 rn c V) o • W � d Vm whm s belms CaIINbdoMYlKldIq JOB NUMBER 18025 DRAWING NAME 18025 -C4.3 -WEND C4.3 13 OF 15 CEMENT CONCRETE DRIVEWAY ENTRANCE TYPE 4 PER WSDOT SP F-80.10-04 (TYP) I f r 1 r .............� 1 ri/( ' i 'Y � / j � i + / a ' t` J 3 �5.2 R � 'r I -� J' 26 L.F.8"O HDPEC®I.01% -3 ------ ___ �-L--_-_ ' I It � 1�� n _�— _ � . - o w �w� ' CB /15 339 n Jq0 I -'I "' _�-- / - 17 �� _ .�.� �7�` .. F. �� dT'J L'A Y g w' W w w`— k w w' —oo--=�'—'00------- O— x — M— s o+ ss _' � ��339 ss ss � �. ss 3 O_ A �� � � �� \ /—�� ��� _338 � � � ��� �� z \ / \ ...._ 355 350 345 340 335 330 SCALE: 1`=30 FEET I�-�1 _ ` 0 15 30 60 \ t .i', \ 1 I �� t � � / � / � � � g � � \ ' + � IE: 332.5 � � t t i % + I 5°, ` J \ 1p' 50 L.F. 8"0 HDPE ®5.62% j I / L unuTY g I � ' - — -� � DEED "EASEMENT N ' ` � w ` /� � t ' � -3 --------- 8' ROW /�--------� - - ---- /( w � i -N_ - - — � - — - .� P rnj- -i - — -may Y t ` ¢� 1 3AB J� � � �'?.9 – ! � '�38� C8 X16 " � t - ! �, a w w w K w '"'� - x —O — _ —_ —. _ _ —O— �— — a_ 1+j5 SS �347� SS_ + s - � - - NORTHERN PACIFIC RD NW �! _20' � —� w w w= w w w—�+ w —�. w w— /�� w0 a��' �S �'ho /��9 33a� ss C _n �33g __ J�� s � - - - � - � � - � — - 1 - — - - — - � — -�-� r� _�_�_ .HOW FAR SHOULD WE TRANSITION � - AND SHOULD GRIND/OVERLAY EXTEND TO END OF TRANSITION? 355 �j7�in 1+UU Y��I�) 3+00 4+00 5+00 6+00 7+00 345 335 330 8+00 m. rn o 0! K K N M � II m Y m m m 8 8 (���(JFJjj � w 0 O U 6 U 3 U' z J U } U W O: a Z F z W W � LL O O baa Wiz wWa oaz ~ J za O LL � � a� C a �� �L Z a d � C � ■- � � w C a W � � z a .. c� � 3 � m� W .a o d� JDB NUMBER 18025 DRAHING NAME 18025_C5.1J-lPP C5.1 14 OF 15 PROFILE i i I iSCALE-30' � HORI ONTAL T' ! VE 11CAL ' CALE � i i CB 16: TYPE 1 —j I STA. 6+83 CB 15, TYPE 1 6.35' LT II ST 0+45.69 j W/ 81 -DIRECTIONAL VANED GRATE ! 15.24' LT PER WSDOT SP B-30.40-02 W/ RECTANGULAR VANED GRATE RIM=337.23 EX CL PROFlLE EX SAWCUT PROFlLE � PER WSDOT SP 8-30.40-02 IE OUT (S)=335.31 RIM=338.41 i IE OUT=336.5 (N) i 11 � i 3 -- ---- ___ -_� --- -- --- - �-- -- - ___ ---- --- - - - - - - _- - - --- - - --- � ' —_� __= _-- ---- - _ - —�-- =__ _- -- — j '-- - --- f--== i I i i i � DESIGN EOP PROFlLE _- __�____ -`---- --� '--' -- ELEV. t 338.35 U I ]] _-- - ---- -- = -- I 3 I Q I I � � EX SWACUT ELEVATIONS DESIGN EOP � I EIEVAnONS I E " EX CL ELEVATIONS i � 3 1f) h � O 1'�� �n� 1nN 00 1t)µ�N <h0 �1�0 <hi MOi .�}} M�-00 011D h�0) MO)d' 01010 1!)�In Or uJ�l� MOw) .-N 40 a0 x0110 1n 1qM t040 V) NN�� 1010) O�� Naf10 MO 1��� Nrn� m0.- 0001p Nrn'h �OaO fDNO aOY� OfO d' N01 t0 ���40 10N 01 ISM .-- rnNiM Ong �m1p NO 00 N01 �h (01 MOi40 Olga} i��M 4010] 00010 st 01 NI�� M M� MMaO MMS m�,'m 010Im W0101 O>01'Ol Om Oi OW Qj OOIOj OO pi 00 OOiO' 00 00 aµ O 00 00 000 OO Oi OOf pj 0j pj I Oj00 40 mem OD 00i^ mrn rr nn:n a0rn 0r M M MM M MMM MMM MMM MMM MMiM d'MM V'M �'d'M MMI ��M Y�� arm � �`f� �QY fid' < fid' I� `r `!-�� �d'M d'MM MM MMM MMM MMi7 MMM MMM MMlM MMM MM /001 MM' MM�.M MM M MM MM'M MMM MM MM M MMM MMM MMM MM MMM MMM M MM MMS MMM MM MM MMM MMM MMIM MMM MM MM`M MMM MM MMI �j7�in 1+UU Y��I�) 3+00 4+00 5+00 6+00 7+00 345 335 330 8+00 m. rn o 0! K K N M � II m Y m m m 8 8 (���(JFJjj � w 0 O U 6 U 3 U' z J U } U W O: a Z F z W W � LL O O baa Wiz wWa oaz ~ J za O LL � � a� C a �� �L Z a d � C � ■- � � w C a W � � z a .. c� � 3 � m� W .a o d� JDB NUMBER 18025 DRAHING NAME 18025_C5.1J-lPP C5.1 14 OF 15 I.. ,•1 7 R R/W 0' 56' 10' y C y�I m5' 7' 5' 11' 11' 5' 7' 54I m I> z 0 I ODS i £I ARIES I� n o - - 60 m fI n x ~ a p m I m xl _ VARIES 2.5' 0 0 I 1 2.5'1 0 I P} z J •* M1' 12R �2% 2R 2 10Y. �P} 1 �^ `CEMENT CONC. BARRIER CURB AND GUTTER CITY OF YELM DEPT, OF PUBLIC WORKS GENERAL NOTES: COMMERCIAL COLLECTOR 1, NO "ON STREET" PARKING PERMITTED, 2, REFER TO RELEVANT SECTIONS OF THE APPROVED 49/21/2000 No. DEVELOPMENT GUIDELINES FOR ADDITIONAL _ 4 INFORMATION ON STORM DRAINAGE, STREET LIGHTING, PAVEMENT STRUCTURE, ECT, DES. DWN. JEG TYPE 1/2' WIDTH ?"' GU` KEEP MULCH 6" FROM TREE TRUNK. ONE-WAY TWO-WAY 10' 10' 15' 30' 20' 40' NOTES: 1. WHERE APPROACH EXCEEDS 16' WIDTH A FULL DEPTH EXPANSION JOINT SHALL BE PLACED LONGITUDINALLY, CENTERED IN THE APPROACH. 2. FORM AND SUBGRADE INSPECTION ARE RE BEFORE POURING CONCRETE. 3. REFER TO SECTION 4B.W. YELM DE,001111 CUIDEUNES. TYPE II TYPICAL CUR B BOTTOM OF RAMP MAY HAVE MAX. 1/2" UP AT 45', 12'1 FLOW UNE OF GUTIER 1/2 LIP DETAIL NOTES: 1. RAMP TEXTURING IS TO BE DONE WITH AN E%PANDED METAL GRATE PLACED AND REMOVED FROM WET CON. TO LEAVE A DIAMOND PATTERN. THE LONG AXIS OF THE DIAMOND PATTERN SHALL BE PERPENDICULAR TO THE CURB, GROOVES SHALL BE 1/8" DEEP AND 1/4" WIDE 2. CURB RAMPS SHALL BE POURED AS A SEPARATE UNIT FROM THE SIDEWALK AND FROM THE CURB AND GUTTER, ISOLATED BY EXPANSION JOINT MATERIAL ON ALL SIDES EXCEPT AT END OF RAMP NEXT TO ROADWAY. APP 3. INLETS SHALL BE LOCATED SO THAT RUNOFF DOES NOT FLOW PAST THE CURB RAMP. NO INLETS ARE TO BE SET SO THAT PEDESTRIANS WALK OVER OR AROUND THEM, TYPE IV RAMP S NOTE SEE SIDEWALK SPACING, EXPANSION JOINTS k SCORE MARK DETAIL FOR ADDITIONAL NOTES. 5' AS SEE MIN, REOD, P 4L DETA L 11 12 RAMP SECTION TYPICAL CURB RAMPS PUB WORKS DIRECTOR DATE 4 G 12 S CITY OF YELM F PUBLIC WORKS E CONCRETE IAP OACH S -C I S -C I S -C PLANTER STRIP (AS REO.) r._1r:T:Tr.>r�Lr.1�R NOTES: 15' 5' 5' 5' EXPANSION JOINT 17.11:77 SIDEWALK PLANTER STRIP 5' MIN (AS REO.) . + .. —2R R=1/2" TYP. 1. TJ(PANSION JOINT MATERIAL TO BE 3/8' THICK PREMO➢ED JOINT FlL1.ER FULL THICKNESS OF CONCRETE. 2. FONM AHD SUBGRADE INSPECTION REWIRED BEFORE POURING CONCRETE, 3. SCORE MARKS SHALL BE 31/8" WDE BY 31/4' DEEP. FOR DEPT. 9DEWALKS OVER 8' IN WDTH, A LONGITUDINAL SCORE MARK SHALL BE MADE ALONG CENTER OF WALK. 4. EXPANSION JOINTS SHALL BE INSTALLED IN CURB AND GUTTER AND IN SIDEWALK AT PC AND PT AT ALL CURB RETURNS. EXPANSION JOINTS SHALL BE PLACED RI 9DEWALK AT SAME LOCATIONS AS THOSE IN CURB AND APPROVED GUTTER WHEN SIDEWALK IS ADJACENT TO CURB AND WITTIER, UNLESS OTHERWISE DIRECTED BY ENGINEER. SIDEWALK 2" DEPTH OF BARK MULCH. KEEP MULCH 6" FROM TREE TRUNK. PRESSURE TREATED 4X6 0 (2 REOD., LENGTH VARIES) PINNED IN PLACE WITH TWO 2X2 PRESSURE TREATED STAKES 24" LENGTHS OF j5 REBAR s SPACED EVENLY OUTSIDE THE HOLE FOR THE ROOTBALL, AND PARALLEL TO THE ROAD (2 REOD. GEOTEX7ILE ROOT CONTROL SYSTEM 15' LONG, CENTERED ON TREE (TWO RE00.) a 12 GA. WIRE TREE TIE W/ RUBBER 6, z PROTECTION AT THE TREE MIN (FASTEN LOOSELY) CURB GUTTER FOR USE WHEN TREE IS WITHIN 6' OF CURB AND/OR SIDEWALK 2' DEPTH OF BARK MULCH IN STREET TREE SPECIFICATIONS: 6' DIAM, CIRCLE CENTERED ON TREE, 1. TREES SHALL BE 2" TO 3" CALIPER KEEP MULCH 6" FROM TREE TRUNK, MEASURED 6" ABOVE THE BASE, 2. TREES SHALL HAVE A MINIMUM 2X2 PRESSURE TREATED STAKES 6 FOOT FREE -OF -BRANCH SPACED EVENLY OUTSIDE THE CLEARANCE, MEASURED FROM ROOTBALL, PARALLEL TO THE ROAD, (2 REOD.) THE GROUND UNE TO THE � H FIRST BRANCH. 3. 1REES SHALL BE SPACED 35 FEET ON CENTER STARTING 15 FEET FROM THE PROPERTY 12 GA, WIRE TREE TIE W/ RUBBER PROTECTION AT THE TREE UNE. (FASTEN LOOSELY) FOR USE WHEN TREE IS NOT WITHIN 6' OF CURB AND/OR SIDEWALK CITY OF YELM NOTES: DEPT, OF PUBLIC WORKS 1. THE GEOTEXDLE ROOT CONTROL SYSTEM SHALL BE 12 INCH BIOBARRIER STRIPS, OR APPROVED EQU AL STREET TREE 2, WIRE TREE TIE SHALL BE 42" ABOVE THE GROUND 3. FINISH GRADE FOR BARK MULCH SHALL RE 1 70 2 INCHES BELOW SURROUNDING GRADE APPROVED DWO. NO. PUBLIC WORKS DIRECTOR DATE 4-19 DES. DVN, CKO. DATE JEG S -c s -c s -c 10/3/94. EDGE AROUND EACH PANEL -BROOM FINISH EXPANSION JOINT CITY OF YELM OF PUBLIC WORKS CEMENT CONCRETE SIDEWALK D PUBUC WORKS DIRECTOR DATE 4-N11 S -C S -C I S -C APPROVED FOR CONSTRUCTION 6Y: DATE: _ DIRECTOR OF %RUC NOtKS 0 s a z A m � H w zz D � U 3 z J U v a Z � 0 U f. Z W � J Ow � O a� � Z W Q W Z O z � LL ENO���C' S/DNA i Q � � d C a W � � za � m � � Lww»n,n hNovc kreyDudJg JOB NUMBER 18025 DRAWING NAME 18025_C5.2�IND C5.2 15 OF 15